Shallow co-location of water, sewer and district heating pipes:

Applicability in cold climate regions

Youen Pericault

Urban Water Engineering

Department of Civil, Environmental and Natural Resources EngineeringDivision of Architecture and Water

ISSN 1402-1757ISBN 978-91-7790-326-0 (print)ISBN 978-91-7790-327-7 (pdf)

Luleå University of Technology 2019

LICENTIATE T H E S I S

Youen Pericault Shallow co-location of w

ater, sewer and district heating pipes

Page 2: Shallow co-location of water, sewer and district heating pipesltu.diva-portal.org/smash/get/diva2:1294643/FULLTEXT01.pdf · rankades som det tredje bästa alternativet medan konventionella

Shallow co-location of water, sewer and district

heating pipes:

Applicability in cold climate regions

Youen Pericault

Luleå, 2019

Division of Architecture and Water

Department of Civil, Environmental and Natural Resources Engineering

Luleå University of Technology

Page 3: Shallow co-location of water, sewer and district heating pipesltu.diva-portal.org/smash/get/diva2:1294643/FULLTEXT01.pdf · rankades som det tredje bästa alternativet medan konventionella

Printed by Luleå University of Technology, Graphic Production 2019

ISSN 1402-1757 ISBN 978-91-7790-326-0 (print)ISBN 978-91-7790-327-7 (pdf)

Luleå 2019

www.ltu.se

Cover image: credits Göran Olsson, Elgocell AB.

Page 4: Shallow co-location of water, sewer and district heating pipesltu.diva-portal.org/smash/get/diva2:1294643/FULLTEXT01.pdf · rankades som det tredje bästa alternativet medan konventionella

i

Preface

The work presented in thesis was conducted in the Urban Water Research Group at the de-

partment of Civil, Environmental and Natural Resources Engineering of Luleå University of

Technology. The studies were carried out within the research cluster Stormwater & Sewers

(Dag & Nät), a collaboration between the Urban Water Research Group, the Swedish munici-

palities of Luleå, Boden, Skellefteå, Östersund, Umeå (VAKIN) and Sundsvall (MSVA), as well

as VA Syd. The research cluster Stormwater and Sewers is supported by the Swedish Water and

Wastewater Association (Svensk Vatten). The studies were also funded by Sweden’s Innovation

Agency (Vinnova) through the Attract project (No. 2014-04287) and by the Swedish Research

Council (Formas) through the Alice project (No. 2011-1710).

The field evaluation of the pipe co-location solution would not have been possible without the

previous work of Göran Olsson (Elgocell AB) and Mattias Vesterlund (LTU) in planning, in-

stalling and maintaining the temperature monitoring system of the “Kapellet” area in Kiruna.

Thank you, Göran and Mattias, for the preparatory work, the “hands on” but also “head down”

introduction to the study site and for systematically have provided me with the information and

help I needed. The utility company of Kiruna (TVAB i Kiruna) is gratefully acknowledged for

providing access cards to “Teknikhuset” at the study site. I would like to express also my grati-

tude to Mikael Risberg (LTU) for the smooth and efficient collaboration and for contributing

to the work with his expertise on thermal modelling. I would like to thank Deniz Dagli (for-

merly LTU) for taking time to show me the basics of soil thermal modelling. I send also my

gratitude to Lars Dyrlind and Mikael Eliasson (Gällivare Municipality) and Torbjörn Jansson

(Skandinavisk Kommunalteknik) for kindly providing data for the sustainability analysis. I

would like to acknowledge the participants of the weighing workshop in Gällivare for their

contribution to the study. I express also my gratitude to Erik Kärrman (RISE) for the valuable

guidance and knowledge sharing when structuring the sustainability analysis.

I am particularly grateful to my supervisors Annelie Hedström and Maria Viklander for their

steady guidance, positivity and trust. Thank you, Annelie, for always clarifying my work and re-

lating it to the (future) needs of the water sector and of society in general. It is motivating!

Thank you also for the good planning and organisation, it brings rhythm into the PhD process.

Maria, I am grateful that you regularly bring fresh and challenging insight into my work. Thank

you also for making the Urban Water Research Group that active, welcoming and supportive. I

am grateful to all my colleagues; you make the work atmosphere so pleasant and stimulating.

Thank you, Brenda, for the interesting “multi-criteria” discussions and contagious optimism. To

Fredrik, thanks for being such a helpful office-mate (and for the Japanese sweets). Hendrik, I

enjoyed helping you on the “summer swales” and learned a lot in the process. Thank you, Joel,

for the good company and support in Kiruna, under the polar night, the midnight sun, and the

freezing autumn rains. I would like to thank also SJ and Norrtåg for the beautiful early morn-

ing rides through the Swedish subarctic. Cristina, your special support and meridional cuisine

was the key to staying focused and energised during the hectic writing weeks. Thank you!

Youen Pericault

Luleå, April 2019

Page 5: Shallow co-location of water, sewer and district heating pipesltu.diva-portal.org/smash/get/diva2:1294643/FULLTEXT01.pdf · rankades som det tredje bästa alternativet medan konventionella

ii

Page 6: Shallow co-location of water, sewer and district heating pipesltu.diva-portal.org/smash/get/diva2:1294643/FULLTEXT01.pdf · rankades som det tredje bästa alternativet medan konventionella

iii

Abstract

In cold climate regions, extensive earthworks are required to install drinking water and

sewer pipes below the frost line. This leads to high installation costs and increased dis-

turbances to traffic and local businesses during repair or rehabilitation activities. Many

cold climate cities are equipped with a district heating network, but the economic via-

bility of expanding these networks to new sub-urban developments is jeopardized by a

decrease in heat demand from new energy efficient buildings. In response to these chal-

lenges, a technical solution was recently developed in Sweden, to co-locate drinking

water, sewer and district heating pipes in a shallow trench above the frost depth, thereby

cutting total installation costs. In this solution, freeze protection of the drinking water

and sewer pipes is ensured by using an insulated utility corridor and a heat-tracing pipe

that recirculates return water from the district heating system. Since this solution was

recently developed, there is little knowledge of its impact on drinking water and sewage

temperatures and its sustainability in comparison to other, more traditional, alternatives.

These aspects are however essential when it comes to the applicability of this solution in

cold climate regions. Hence, the objectives of this thesis were (i) to evaluate the ability

of the co-location solution to maintain drinking water and sewer pipes within a safe,

comfortable and non-freezing temperature range and (ii) to compare this solution to

more traditional heat and water services provision alternatives from a sustainability point

of view. To address objective (i), pipe temperatures were measured continuously at two

cross sections at a pilot site in Kiruna during a period of 22 months. A thermal model,

set up and calibrated on the basis of the measurements, was used to simulate the impact

of extraordinary cold weather conditions on the pipe temperatures. The results showed

that the utilidor could keep pipe temperatures within the desired ranges (i.e. >0°C for

sewer; 0-15°C for drinking water) in most cases, but that special care should be taken

during design to limit drinking water temperature in the summer case. To address objec-

tive (ii), five provision alternatives for heat, water and sewerage were selected and their

performance with regard to seven sustainability criteria were evaluated. Three environ-

mental (climate preservation, energy efficiency, and material efficiency), one economic

(affordability), one social (user friendliness), one health & safety (workers’ safety) and

one technical (reliability) criteria were considered. A multi-criteria method was then

applied to propose a sustainability ranking of the alternatives based on a set of weights

obtained from local stakeholders. The stakeholders selected for the case study, assigned

most weight to the reliability (29%), energy efficiency (24%) and affordability (24%) cri-

teria. The co-location solution was outranked by two alternatives featuring geothermal

heat pumps instead of district heating. A sensitivity analysis was performed and showed

that the co-location solution (A2*) could potentially top the sustainability ranking if

geothermal energy was used as the district heating source, or if the weight given to af-

fordability increased from 24% to 52%, because A2* was the cheapest alternative.

Page 7: Shallow co-location of water, sewer and district heating pipesltu.diva-portal.org/smash/get/diva2:1294643/FULLTEXT01.pdf · rankades som det tredje bästa alternativet medan konventionella

iv

Page 8: Shallow co-location of water, sewer and district heating pipesltu.diva-portal.org/smash/get/diva2:1294643/FULLTEXT01.pdf · rankades som det tredje bästa alternativet medan konventionella

v

Sammanfattning

I nordliga regioner, består en stor del av investeringskostnaderna för nya VA-ledningsnät

av det schaktningsarbete som behövs för att lägga ledningarna på frostfritt djup. Samti-

digt minskar fjärrvärmens lönsamhet i nya stadsdelar på grund av låg värmeförbrukning

i energieffektiva byggnader. Som svar på dessa utmaningar har en lösning utvecklats och

som innebär samförläggning av fjärrvärme- och VA-ledningar i ett grunt schakt, för att

på så sätt minska investeringskostnaderna, både för VA- och fjärrvärmeverksamheten. En

isolerad kulvert i cellplast samt en frostskyddsledning i vilken returvatten från fjärrvär-

mesystemet återcirkuleras används för att hålla VA-ledningarna frostfria. Eftersom denna

typ av samförläggning inte tidigare utvärderats finns ännu liten kunskap om hur vatten-

temperaturerna i ledningarna påverkas samt om hur systemet står sig hållbarhetsmässigt i

relation till andra mer traditionella system. Därför var syftet med denna avhandling att

utvärdera systemets förmåga att hålla dricksvattenstemperaturen på ett komfortabelt och

hälsosäkert värde (under 15○C) och hålla dricksvatten- och avloppsledningar frostfria

(över 0○C). Vidare var syftet att jämföra hur hållbart detta system är för att distribuera

dricksvatten och värme samt avleda avloppsvatten, i relation till andra system.

För att utvärdera vattentemperaturerna mättes vattentemperaturerna i två tvärsnitt av

kulvertssystemet i ett pilotvillaområde under 22 månader. En termisk modell kalibrera-

des med temperaturmätningar från ett av de två tvärsnitten och användes därefter för att

simulera ledningstemperaturer under den kallaste vintern som registrerats i testområdet

(Kiruna, 1986-1987). Resultaten visade att samförläggningskulverten kunde hålla vattnet

inom det önskade intervallet (>0°C for avlopp samt 0-15°C for dricksvattnet) under en

stor del av tiden. Resultaten visade dock att i ett fortsatt utvecklingsarbete behöver hän-

syn tas till hur isolerkulverten bör utformas och förläggas för att undvika för höga

dricksvattentemperaturer på sommaren, då dricksvattnet maximalt uppmättes till +19°C.

En multikriterieanalys användes för att utvärdera fem alternativa system för tillhanda-

hållning av värme och VA till ett bostadsområde. Den relativa hållbarheten för alternati-

ven utvärderades utifrån klimatpåverkan, energi- och materialeffektivitet, kostnader, an-

vändarvänlighet, arbetesmiljösäkerhet och tillförlitlighet. Vikter för kriterierna erhölls

från lokala intressenter under en workshop. Intressentgruppen satte högst vikt vid tillför-

litlighet (29%), energieffektivitet (24%) och kostnader (24 %). Samförläggningslösningen

rankades som det tredje bästa alternativet medan konventionella djupt förlagda VA-

ledningar med bergvärmepumpar i varje fastighet istället för fjärrvärme rankades högst.

En känslighetanalys visade dock att samförläggningslösningen skulle rankas högst om

värmen producerats i det nya bostadområdet med en enda stor bergvärmepump och

distribuerats som närvärme, eller om kostnaderna hade givits mer vikt vid beslutet, ef-

tersom samförläggningslösningen var den billigaste.

Page 9: Shallow co-location of water, sewer and district heating pipesltu.diva-portal.org/smash/get/diva2:1294643/FULLTEXT01.pdf · rankades som det tredje bästa alternativet medan konventionella

vi

Page 10: Shallow co-location of water, sewer and district heating pipesltu.diva-portal.org/smash/get/diva2:1294643/FULLTEXT01.pdf · rankades som det tredje bästa alternativet medan konventionella

vii

Table of Contents

Preface ......................................................................................................................... i

Abstract ...................................................................................................................... iii

Sammanfattning ............................................................................................................ v

List of papers ............................................................................................................... ix

1. Introduction ....................................................................................................... 1

1.1. Study aim ........................................................................................................ 3

1.2. Thesis structure ............................................................................................... 3

2. Background ........................................................................................................ 5

2.1. Co-location of utility pipes above the frost line ................................................ 5

2.2. Temperature performance of sewer and drinking water networks ..................... 7

2.3. Sustainability assessment of utility pipe networks ............................................. 8

2.3.1. Definitions and assessment frameworks ...................................................... 8

2.3.1. Sustainability assessment of water service networks .................................... 9

2.3.2. Sustainability assessment of district heating networks ............................... 10

2.3.3. Multi-criteria analysis methods for assessment of infrastructures .............. 11

3. Methods ............................................................................................................ 15

3.1. Evaluation of temperature performance ......................................................... 15

3.1.1. Study site ................................................................................................ 15

3.1.2. Regulation of the heat tracing system ..................................................... 16

3.1.3. Temperature measurements ..................................................................... 18

3.1.4. Initial model ........................................................................................... 20

3.1.5. Model calibration .................................................................................... 20

3.1.6. Model validation ..................................................................................... 21

3.1.7. Modelling of exceptionally cold conditions ............................................. 21

3.2. Sustainability assessment ................................................................................ 22

3.2.1. Functional unit and system boundaries .................................................... 22

Page 11: Shallow co-location of water, sewer and district heating pipesltu.diva-portal.org/smash/get/diva2:1294643/FULLTEXT01.pdf · rankades som det tredje bästa alternativet medan konventionella

viii

3.2.2. Selection of alternatives ........................................................................... 22

3.2.3. Case description ..................................................................................... 24

3.2.4. Criteria and associated indicators ............................................................ 26

3.2.5. Calculation of sustainability scores ........................................................... 28

3.2.6. Sensitivity analysis ................................................................................... 29

4. Results ............................................................................................................... 31

4.1. Temperature performance .............................................................................. 31

4.1.1. Measured pipe temperatures .................................................................... 31

4.1.2. Impact of heat tracing and soil temperature ............................................. 33

4.1.3. Model performances ............................................................................... 35

4.1.4. Modelled pipe temperatures under exceptionally cold conditions ............ 36

4.2. Sustainability ................................................................................................. 37

4.2.1. Indicator values ....................................................................................... 37

4.2.2. Criteria scores ......................................................................................... 38

4.2.3. Criteria weights ...................................................................................... 41

4.2.4. Sustainability scores and ranking ............................................................. 41

4.2.5. Sensitivity analysis ................................................................................... 43

5. Discussion ......................................................................................................... 45

5.1. Comparison with conventional solutions ....................................................... 45

5.1.1. Freeze protection .................................................................................... 45

5.1.2. Summer temperatures ............................................................................. 46

5.1.3. Sustainability ........................................................................................... 47

5.2. Indicator normalization and aggregation ........................................................ 49

5.3. Suggestions of improvement of the technical solution .................................... 51

6. Conclusions ...................................................................................................... 53

References ................................................................................................................ 55

Page 12: Shallow co-location of water, sewer and district heating pipesltu.diva-portal.org/smash/get/diva2:1294643/FULLTEXT01.pdf · rankades som det tredje bästa alternativet medan konventionella

ix

List of papers

Paper I Pericault, Y., Risberg, M., Viklander, M., Hedström, A. (submitted) Temperature

performance of a heat-traced utilidor for sewer and water pipes in seasonally

frozen ground. (Submitted to Water Research, April 2019).

Paper II Pericault, Y., Risberg, M., Vesterlund, M., Viklander, M., Hedström, A. (2017) A

novel freeze protection strategy for shallow buried sewer pipes: temperature

modelling and field investigation. Water Science and Technology, 76-2, p. 294-

301.

Paper III Pericault, Y., Kärrman, E., Viklander, M., Hedström, A. (2018) Expansion of sew-

er, water and district heating networks in cold climate regions: an integrated sus-

tainability assessment. Sustainability, 10-10.

Paper IV Pericault, Y., Kärrman, E., Viklander, M., Hedström, A. (2018) Data supporting

the life cycle impact assessment and cost evaluation of technical alternatives for

providing water and heating services to a suburban development in Gällivare

Sweden. Data in Brief, 21, p. 1204-1208.

The author’s contribution to the papers is summarized in the table below:

Responsible – developed, consulted (where needed) and implemented a plan for completion of

the task.

Shared responsibility – made essential contributions towards the task completion in collabora-

tion with other members of the research team

Contributed – worked on some aspects of the task completion

No contribution – with valid reason, has not contributed to completing the task (e.g. joining the

research project after the task completion)

NA – not applicable

Paper

Nr.

Develop-

ment of idea

Research

study design

Data

collection

Data processing

and analysis

Data

interpretation

Publication process

Manuscript

preparation

for

submission

Responding

to reviewers

I Shared

responsibility Responsible Responsible

Shared

responsibility Responsible Responsible NA

II Contributed Shared

responsibility Responsible

Shared

responsibility Responsible

Shared

responsibility Responsible

III Shared

responsibility

Shared

responsibility Responsible Responsible Responsible

Shared

responsibility Responsible

IV Responsible Responsible Responsible Responsible Responsible Responsible Responsible

Page 13: Shallow co-location of water, sewer and district heating pipesltu.diva-portal.org/smash/get/diva2:1294643/FULLTEXT01.pdf · rankades som det tredje bästa alternativet medan konventionella

x

Page 14: Shallow co-location of water, sewer and district heating pipesltu.diva-portal.org/smash/get/diva2:1294643/FULLTEXT01.pdf · rankades som det tredje bästa alternativet medan konventionella

1

1. Introduction

Cold climate regions are characterized by a mean temperature below -3○C during the

coldest month (Köppen, 1884; Beck et al., 2018) and host more than 450 million people

in countries such as Russia, China, USA, Canada, Norway, Sweden, and Finland. In

these regions, drinking water and sewerage infrastructures need to be functional, even

during the freezing season. Indoors, this is normally achieved by the use of insulated

buildings and reliable heating systems that maintain year-round positive ambient tem-

peratures. Outdoors, conventional solutions for freeze protection of drinking water and

sewer pipe networks vary depending on the severity of the climate. In settlements built

on permafrost or bedrock type terrain, pipes are traditionally insulated, heated, and laid

in a shallow trench or above ground (Smith, 1996; Schubert et al., 2013). In milder loca-

tions, pipes are traditionally buried below the local frost depth (e.g. 1.6 m in Stockholm;

2 m in Harbin; 2.4 m in Edmonton). Both approaches are implemented through well-

established robust technical solutions and practices, usually benefiting from several dec-

ades of operational feedback and trial-error cycles. However, they are still resource in-

tensive and have a number of negative socio-environmental impacts, which should be

addressed to support the transition of cold climate regions toward more sustainability.

Burial below the frost depth (usually referred to as the frost line) is laborious and leads

to high, long-term investments while water utilities need to increase investments in

network renewal (Malm et al., 2013; ASCE, 2017), and face high uncertainties concern-

ing future population trends and the impact of climate change (Galloway, 2011). Moreo-

ver, interventions on these deep pipe networks for repair or rehabilitation require large

excavations, which are known to disturb traffic and local businesses (Hunt et al., 2014).

Besides, pipes installed just below the frost line are constantly at a positive but rather low

temperature, which is detrimental to wastewater treatment (Henze et al., 2001), and

wastewater heat recovery (Meggers and Leibundgut, 2011). On the other hand, shallow

or above-ground pipe installation strategies have traditionally been based on the use of

direct electrical heating (Gunderson, 1978) or combustion of fossil fuels for freeze pro-

tection (Smith, 1996; Schubert et al., 2013). These systems also require more care during

operation to prevent freezing, and can sometimes lead to undesirably warm drinking

water during summer (Reed 1977, as cited in Smith, 1996)

Concerning space heating and preparation of hot tap water, many cold climate commu-

nities are equipped with a district heating system. These systems have shown multiple

benefits as they allow efficient use of fuels through combined heat and power (CHP)

generation, avoid distributed air pollution, and allow the reuse of waste heat from indus-

tries (Werner, 2017). However, it is increasingly hard to achieve economic viability for

district heating projects in new suburban areas. The investment and operational (e.g. heat

loss) costs of expanding the pipe network to the new area remain unchanged, while the

Page 15: Shallow co-location of water, sewer and district heating pipesltu.diva-portal.org/smash/get/diva2:1294643/FULLTEXT01.pdf · rankades som det tredje bästa alternativet medan konventionella

2

amount of heat sold to customers is decreasing due to more energy efficient building

(Werner, 2017). Sometimes, the number of future customers is also uncertain due to the

competing heat pump market. Moreover, conventional district heating pipe networks

operating at high temperature (60-90○C) are ill-suited to integrate with renewable ener-

gy sources. Yet, district heating has been identified as an important part of future renew-

able energy systems (Connolly et al., 2014) if they undergo a change toward low tem-

perature networks called fourth generation district heating (Lund et al., 2014). In such

distribution networks, heat is transported at a lower temperature level (30-60○C) making

it possible to utilize renewable low temperature heat sources (shallow geothermal, solar)

and low temperature industry heat-waste (e.g. data centre, wastewater heat recovery).

Fourth generation district heating also aims to address the problem of economic viabil-

ity by reducing installation cost by the use of flexible easy-to-connect pipes and by re-

ducing heat loss to the surrounding soil. The rate of adoption of fourth generation in

cold climate regions is, however, low and this necessary transition has not truly started in

Sweden (Werner, 2017).

Recently, a pipe co-location solution integrating low temperature district heating, sew-

erage, and water supply has been developed and built in Northern Sweden where the

normal recommended depth for installation of water and sewer pipes is typically larger

than 2 m. The different pipes are insulated and installed in a common shallow trench (~

1 m) and heat from the low temperature district heating system is used to protect the

sewer and drinking water pipes from freezing. This solution aims at reducing total exca-

vation costs and appears to have the potential to solve several of the above mentioned

challenges of heat and water services provision in cold climate regions. Hence, it is rele-

vant to advance the knowledge and understanding of this novel co-location strategy. In

particular, freezing risks, impacts on drinking water and sewage temperature and relative

sustainability in comparison to conventional solutions are essential aspects when it

comes to selecting, designing and operating shallow pipe co-location solutions.

Page 16: Shallow co-location of water, sewer and district heating pipesltu.diva-portal.org/smash/get/diva2:1294643/FULLTEXT01.pdf · rankades som det tredje bästa alternativet medan konventionella

3

1.1. Study aim

As described above, a technical solution for co-locating sewer, water, and district heating

pipes in a shallow trench above the frost line has been recently developed and imple-

mented on a pilot site in Northern Sweden. The main driver for the project was to re-

duce investment costs, and thereby improve the economic viability of district heating in

a context of decreasing residential heat demand. However, the technical, economic, en-

vironmental, and social impacts of implementing this pipe co-location solution have so

far not been investigated. Hence, the overall aim of this thesis was to advance the under-

standing of this technical solution, and assess its applicability to cold climate regions.

The research objectives were:

(1) To evaluate the ability of the solution to maintain drinking water and sewer pipes at

a safe, comfortable and non-freezing temperature range through the specific sub-

objectives:

a. To evaluate pipes and soil temperatures at two trench sections on the pilot

site of Kiruna for different weather and heat-tracing conditions,

b. To simulate the impact of extraordinary cold air temperatures on drinking

water and sewer pipe temperatures by setting up and calibrating a two-

dimensional finite volume model of one trench cross section.

(2) To compare the co-location solution to other, more traditional, provision alternatives

for water and heating services with regards to sustainability through the specific sub-

objectives:

a. To evaluate, on a selected case study, quantitative indicators of the environ-

mental, economic, social, health & safety, and technical performances of the

alternatives,

b. To aggregate the indicator values into a relative sustainability score for each

alternative by using a multi-criteria approach, including the priorities of a

group of local stakeholders,

c. To identify favourable conditions for the implementation of the co-location

solution though a sensitivity analysis of the sustainability ranking.

1.2. Thesis structure

The thesis is based on four scientific papers (Figure 1) which assess the temperature per-

formance (Papers I and II) and relative sustainability (Papers III and IV) of the earlier

mentioned shallow co-location solution for sewer, water, and district heating pipes. Pa-

per II deals with the thermal characterisation and modelling of two trench sections on a

pilot site in Northern Sweden, under given weather conditions. Findings from Paper II

provided a basis for the experimental design and modelling related to Paper I (Figure 1).

Page 17: Shallow co-location of water, sewer and district heating pipesltu.diva-portal.org/smash/get/diva2:1294643/FULLTEXT01.pdf · rankades som det tredje bästa alternativet medan konventionella

4

Paper I presents a long-term evaluation of the solution’s temperature performance based

on experimental work on the pilot site and modelling of extraordinary cold conditions.

Paper I also complements the knowledge gained in Paper II to investigate the thermal

behaviour of the solution. Paper IV deals with the evaluation of environmental and

economic lifecycle data related to the co-location solution and more traditional alterna-

tives. These data are used in Paper III, together with social and technical information, to

compare the co-location solution to the other alternatives from a sustainability point of

view (Figure 1). By providing information about the solution’s capacity to fulfil its main

technical function and to improve sustainability, the four papers contribute to the thesis’

overall aim of assessing the solution’s applicability to cold climate regions.

Figure 1. Synthesis of the scientific papers in relation to the thesis topic.

The thesis comprises six chapters: Chapter 1 introduces the research topic and research

objectives. Chapter 2 presents the state-of-the-art concerning shallow co-location solu-

tions for utility pipes and the assessment of utility pipe networks’ temperature perfor-

mance and sustainability. Chapter 3 describes the research methods used to assess tem-

perature performance and relative sustainability. These methods include temperature

measurements in the field, thermal modelling, lifecycle analysis and multi-criteria analy-

sis. Chapter 4 presents the research results, namely measured and modelled pipe temper-

atures, criteria scores, sustainability ranking and a sensitivity analysis of this ranking.

Chapter 5 discusses these results in relation to the research aim and state-of-the-art. In

particular, the co-location solution is compared to other alternatives from a temperature

performance and sustainability point of view. The choice of sustainability indicators and

of methods for their aggregation is also discussed, as well as possible improvement of the

solution. Finally, Chapter 6 presents the conclusions of the research work. The four sci-

entific papers are appended at the end of the thesis.

Applicability of the shallow co-location

solution to cold climate regions

Relative sustainability in comparison

to traditional solutions

Impact of heat tracing and soil tem-

perature

Environmental and economic

life cycle data

Paper IV

Ability to maintain adequate drinking

water and sewer temperatures

Paper I, II

Paper I

Licentiate thesis

Paper III

Page 18: Shallow co-location of water, sewer and district heating pipesltu.diva-portal.org/smash/get/diva2:1294643/FULLTEXT01.pdf · rankades som det tredje bästa alternativet medan konventionella

5

2. Background

2.1. Co-location of utility pipes above the frost line

Co-location of water and sewer pipes in seasonally frozen ground, in permafrost or

above-ground is seen in parts of Scandinavia, Finland, Russia, Alaska and Canada. In sea-

sonally frozen ground, one strategy to reduce excavation needs is to place the pipes in a

shallow trench above the natural frost line and cover them with insulation boards (Fig-

ure 2a), sometimes called frost shields. Other utilities, such as electricity and telecom-

munications, are sometimes placed in the same trench.

Figure 2. (a) Co-location of stormwater (OV), drinking water (V), and sanitary sewer (SP) pipes in a shallow trench under a frost shield – Norway (Gunderson, 1978); (b) Box-utilidor including drinking water, telecommunications and sewer lines – Kilpisjärvi, Finland (Mcfadden, 1990); (c) Box-utilidor in-cluding sanitary sewer (SP), drinking water (V), and electrical lines (El) - Norway (Gunderson, 1978); (d) Shallow utilidor (top is at surface level) containing pipes for heating (steam and condensation re-turn), drinking water, fire extinction, and sewerage - Alaska (Kennedy et al., 1988).

Page 19: Shallow co-location of water, sewer and district heating pipesltu.diva-portal.org/smash/get/diva2:1294643/FULLTEXT01.pdf · rankades som det tredje bästa alternativet medan konventionella

6

Gunderson (1978) developed a design method to determine the width and thickness of

frost shields. The method takes into account the local climate, soil conditions, snow cov-

er, installation depth, and the amount of heat given by the utilities placed under the frost

shield. Gunderson’s method also covers the case of box-shaped frost shields (Figure 2c).

This technique is relatively common in Norway, Sweden, and Finland to perform shal-

low installations of low pressure sewer and drinking water pipes in, for example, rocky

areas. The use of box-shaped frost shields with a gravity sewer (Figure 2b) has also been

reported (Mcfadden, 1990) in an experimental village in Northern Finland. Even

though they are usually filled with sand, box-shaped frost shields can be referred to as

utility corridors (utilidors). In the American and Canadian literature, utilidor refer to “a

structure whose function is to contain the utility piping and wiring of a community or camp.”

(Smith, 1996). Compact insulated utilidors have been used in the permafrost areas of

Alaska and Northern Canada to perform shallow (Figure 2d) or above-ground (Figure

3) installations of the utility pipes. Larger utilidors that can be inspected by walking or

crawling have also been built in these areas (Smith, 1996), as well as in Russia and Swe-

den (Tekniska Verken, 2017). In most documented cases, utilidors are hollow (air space

between the pipes). Design guidelines and advantages/disadvantages of utilidors are pre-

sented in the Cold Climate Utility Monograph (Smith, 1996). According to Schubert et

al. (2013), box (compact) utilidors are part of the current practice for utility services de-

livery in Alaska.

Figure 3. (a) Above-ground utilidor containing drinking water, gravity sewer and district heating pipes, source - Fairbanks, Alaska (Reed, 1977, as cited in Smith, 1996); (b) Above-ground utilidor containing

drinking water, vacuum sewer and heat trace pipe – Noorvik, Alaska (Rogness and Ryan, 1977).

Heat needs to be provided to ensure positive temperatures inside the utilidors (or under

the frost shields). Sometimes the heat given by the sewer and/or drinking water pipes

can be sufficient depending on wastewater/drinking water flows and the drinking water

source (surface or groundwater). Methods are presented in Gunderson (1978) and Smith

(1996) to evaluate the heat gains from these utility pipes, as well as from electricity lines

Page 20: Shallow co-location of water, sewer and district heating pipesltu.diva-portal.org/smash/get/diva2:1294643/FULLTEXT01.pdf · rankades som det tredje bästa alternativet medan konventionella

7

if they are situated in the utilidor/under the frost shield. Single (pitorifices) or double

main recirculation systems (Schubert et al., 2013) are widely used in Alaska and North-

ern Canada to ensure sufficient flows in all sections of a drinking water network. An-

other, less resource efficient, way to maintain drinking water flow is to use bleeders or to

send let-run notices to resident during cold events (Raymond et al., 1999). Alternatively,

heat tracing systems (Smith, 1996) can be installed to protect utilidors/frost shields

against freezing. This can consist of an electric heating cable or a pipe where warm-to-

hot water or water-glycol mix is circulated (Figure 3b). If district heating lines are in-

cluded in the utilidor (Figures 2d and 3a), their insulation can be designed to ensure that

sufficient heat is given along the utilidor to prevent freezing of the drinking water and

sewer pipes. However, this approach offers less control than a dedicated heat tracing sys-

tem and has been reported to lead to undesirably high drinking water temperatures

(Leitch and Heinke, 1970, as cited in Smith,1996; Reed, 1977, as cited in Smith, 1996).

2.2. Temperature performance of sewer and drinking water net-

works

Drinking water temperature plays an essential role in preserving water quality, odour

and taste; it positively affects the re-growth of microorganism in the distribution net-

work and should therefore be kept under 25○C according to the World Health Organi-

zation (2008). An increase in drinking water temperature also accelerates the decay of

chlorine in the distribution network (Li et al., 2003), which can be detrimental to

drinking water quality. It has also been shown that temperature can have a negative ef-

fect on taste, as consumers usually enjoy cooler drinking water (Pangborn and Bertolero,

1972). On the other hand, cold drinking water has a higher viscosity (Blokker and

Pieterse-Quirijns, 2013) and can therefore increase pumping costs.

Temperature is recognized as an important parameter of wastewater because it can

strongly influence several physical, chemical, and biological processes during conveyance

and treatment. The main concern is that too cold wastewater (below 8○C) can drastically

impair the nitrogen treatment process (Henze et al., 2001). In more general terms, cold

wastewater slows the biological treatment processes and may require larger treatment

units. Wastewater temperature also has a direct influence on the wastewater heat recov-

ery (WWHR) process, which is usually performed using heat pumps. WWHR has re-

ceived increased attention in recent years as up to 90% of urban water cycle energy use

is caused by hot domestic water preparation (Olsson, 2012). Whether wastewater heat is

recovered upstream or downstream of the treatment plants, warmer wastewater has been

found to increase the WWHR process efficiency (Meggers and Leibundgut, 2011).

Recognising the importance of temperature in urban water networks and the lack of

previous studies on this topic, several authors have recently focused on measuring, ana-

Page 21: Shallow co-location of water, sewer and district heating pipesltu.diva-portal.org/smash/get/diva2:1294643/FULLTEXT01.pdf · rankades som det tredje bästa alternativet medan konventionella

8

lysing, and modelling thermal processes in sewer (Abdel-Aal et al., 2014; Dürrenmatt

and Wanner, 2014) and drinking water networks (Blokker and Pieterse-Quirijns, 2013).

These studies were performed in temperate regions considering the heat transfer from

one pipe to the surrounding soil without soil freezing. There is therefore a need for

thermal studies of pipe co-location solutions above the frost line as they involve heat

transfer between multiple pipes, and are influenced by the phenomenon of soil freezing.

Heat transfer in frozen soils has been studied extensively in the past (Johansen, 1975;

Farouki, 1981), but applications to water and sewer networks have been limited to the

verification of pipe freeze protection (Kennedy et al., 1988; Coutermarsh and Carbee,

1998).

2.3. Sustainability assessment of utility pipe networks

2.3.1. Definitions and assessment frameworks

Sustainable development has been defined in multiple ways since it first appeared in the

1972 Stockholm conference introduced by the International Union for the Conserva-

tion of Nature. A commonly accepted definition is “Sustainable development is development

that meets the needs of the present without compromising the ability of future generations to meet

their own needs” as introduced in the Brundtland report (WCED, 1987). As noted by

Motevallian and Tabesh (2011), definitions of sustainable development generally put

emphasis on the two following key ideas:

To regard both current and future needs,

To integrate environment, society and economy in the decision-making

process.

From a conceptual point of view, sustainability is usually defined as an ideal status or sit-

uation that is the long-term goal of sustainable development (Mebratu, 1998). From a

more practical point of view, sustainability is used as a system attribute that measures the

compliance of a system to the principles of sustainable development. However, system

sustainability is rarely assessed in an absolute way but rather in relation to other systems

or to previous states of the same system. Assessing relative sustainability is a partly-

qualitative, multidimensional problem that can be approached in various ways (Lai et al.,

2008). Therefore, several authors have developed frameworks with measureable indica-

tors for both urban water and heat supply systems to promote an operational and con-

sistent use of the notion of relative sustainability.

For urban water systems, a framework for assessing relative sustainability was developed

in Sweden as part of the Sustainable Urban Water Management project (1999-2005). In

this framework (Malmqvist et al., 2006), the sustainability criteria are organized in five

categories: health and hygiene; social and cultural; environmental; economic; and tech-

Page 22: Shallow co-location of water, sewer and district heating pipesltu.diva-portal.org/smash/get/diva2:1294643/FULLTEXT01.pdf · rankades som det tredje bästa alternativet medan konventionella

9

nical. A list of criteria and associated indicators was developed during the project and

was presented in Hellström et al. (2000). The authors also identified a list of priority in-

dicators that should be included in the sustainability assessment process. With a similar

aim, a guidebook was produced as part of the UK-based “Sustainable Water-Industry

Asset Resource Decisions” project. In this guidebook, the criteria were organized in

four main categories: economic; environmental; social; and technical (Ashley et al.,

2004). Examples of criteria and indicator were suggested to support water utilities eval-

uating the relative sustainability of different technical alternatives (Foxon et al., 2002).

More recently, a sustainability assessment framework (Brattebø et al., 2013) for urban

water systems was developed as part of the TRUST project (TRansition to sustainable

Urban Systems of Tomorrow). This framework was based on 23 measurable indicators

(Alegre et al., 2014), and proposed the following definition of sustainability for urban

water systems: “Sustainability in urban water cycle services (UWCS) is met when the quality of

assets and governance of the systems is sufficient to actively secure the water sector’s necessary con-

tributions to social, environmental and economic sustainability in the urban system as a whole.”

2.3.1. Sustainability assessment of water service networks

There are few sustainability assessment studies covering drinking water or sewer net-

works and integrating social, technical, environmental, and economic aspects. For drink-

ing water distribution, there is normally no choice to make concerning the main tech-

nology, which is a pressurized pipe network. Some Life Cycle Assessment (LCA) studies

have focused on the problem of drinking water pipe material selection considering one

to seven environmental indicators (Dennison et al., 1999; Piratla et al., 2011; Sanjuan-

Delmás et al., 2014) but did not include economic, social, or technical indicators in the

comparison. For wastewater collection networks, the most common technology is gravi-

ty sewer, but low pressure sewers or vacuum sewers are possible alternatives. Vacuum

sewers have received increased attention in recent years because of their ability to

transport concentrated domestic slurries (black water with or without kitchen waste),

resulting from source separation sanitation strategies. Sewer technologies (gravity, low

pressure, vacuum) have been compared from an integrated sustainability perspective by

Tanskanen (2018). In this study, vacuum sewer was found to be the most sustainable al-

ternative for black water transport in a 280-household residential area in Sweden. Simi-

lar studies are not found in the literature for the conventional case where black and grey

water are transported together. Concerning the choice of wastewater pipe material, de la

Fuente et al. (2016) performed a comparative sustainability assessment of plastic and

concrete pipe for various diameters. They did not find significant differences in sustaina-

bility index between plastic and concrete pipe for the 400 mm diameter case. However,

the difference increased with diameter in favour of concrete pipes. Others studies on

sewer pipe material selection have focused on environmental indicators only (Petit-Boix

et al., 2014; Vahidi et al., 2016) or environmental and economic indicators (Akhtar et al.,

Page 23: Shallow co-location of water, sewer and district heating pipesltu.diva-portal.org/smash/get/diva2:1294643/FULLTEXT01.pdf · rankades som det tredje bästa alternativet medan konventionella

10

2015). Technical alternatives (trenchless vs open-cut) for rehabilitating drinking water

(Koo and Ariaratnam, 2008), and sewer pipes (Ariaratnam et al., 2013), have been com-

pared from a sustainability point of view, using multi-criteria approaches.

The choice of freeze protection strategy for drinking water or sewer pipes has so far not

been the focus of sustainability studies. As introduced in section 2.1, one possible freeze

protection strategy is to co-locate the utility networks in a shallow or above-ground

corridor called a utilidor. Putting aside the problem of freeze protection in cold climate

regions, the question of utility placement (burial in separated trenches, or co-location in

underground utilidors) has been studied from a sustainability perspective in more tem-

perate locations. Hunt et al. (2014) described a method to compare the long-term eco-

nomic, social, and environmental costs of open-cut utility placement versus placement

in a utilidor. The authors developed and applied the economic part of the method to

compare different utilidor designs to the open-cut placement method, for different con-

texts (undeveloped, suburban, and urban) and by using data from the UK. They con-

cluded that utilidors can be a more economically viable alternative in all three location

contexts, depending on the number of utilities that are co-located and the number of

avoided street works during the period of interest. However, Hojjati et al. (2018) re-

viewed available sustainability assessment tools for urban underground utility infrastruc-

ture projects and concluded that none of them was sufficient to integrate the economic,

environmental, and social costs of streetworks in cities in an applicable and transparent

way.

2.3.2. Sustainability assessment of district heating networks

Ghafgazi et al. (2010) developed and demonstrated a multi-criteria approach including

economic, environmental, social, and technical aspects to evaluate district heating system

options. In a similar study, Grujić (2014) compared different district heating system op-

tions for the city of Belgrade by considering economic, environmental, and energy se-

curity aspects. Both of these studies covered heat production but not heat distribution

through the pipe network. Mróz (2008) compared different heat supply strategies for a

residential neighbourhood in Poland with regard to economic, technical, and environ-

mental criteria. The compared options included heat distribution from the existing dis-

trict heating system either by direct expansion of the pipe network or through a local

network operated at lower temperature by using a large heat exchanger. The authors

found no preference between these two options according to the priorities of local de-

cision makers. District heating pipe technologies have not been studied from an inte-

grated sustainability perspective but Persson et al. (2006) and Perzon et al. (2007) per-

formed environmental lifecycle assessments of steel pipes pre-insulated with polyure-

thane foam (for high temperature district heating) and polyethylene pipes insulated on

site with expanded polystyrene (for low temperature district heating), respectively.

Page 24: Shallow co-location of water, sewer and district heating pipesltu.diva-portal.org/smash/get/diva2:1294643/FULLTEXT01.pdf · rankades som det tredje bästa alternativet medan konventionella

11

Decision making on district heating networks is not limited to the choice of distribu-

tion temperature levels and pipe technology for a new urban area. It also includes deci-

sions about whether or not the district heating network should be expanded at all to

this area. In this case, district heating needs to be compared to individual heating systems

from different energy sources (e.g. fossil fuels, biomass, geothermal, direct electricity,

etc.). This question has been addressed from an economic/environmental perspective by

Alanne et al. (2007) and from an economic/environmental/technical perspective by

Mróz (2008). Kontu et al. (2015) conducted a multi-criteria study for various residential

heating options, including district heating, for a new urban area in Finland. The latter

study appears to be consistent with the concept of sustainability assessment as it includes

environmental, economic, social, and also technical aspects. District heating from bio-

mass and individual geothermal heat pumps were found to be the two most preferable

options in this study.

2.3.3. Multi-criteria analysis methods for assessment of infrastructures

Sustainability assessment can be conducted using various methods, not limited to the

family of multi-criteria analysis methods. Lai et al. (2008) grouped them into four main

approaches: cost-benefit analysis (CBA); triple bottom line (TBL); integrated assessment

(IA); and multi-criteria analysis (MCA). In distinction to the other approaches (Lai et al.,

2008), MCA methods are relatively well suited to integrate quantitative and qualitative

criteria, as well as stakeholder participation, into the sustainability assessment process.

However, because they are multi-dimensional, they can require considerable cognitive

effort from decision makers to set-up a preference model (to judge the relative im-

portance of the criteria).

A wide range of MCA methods have been presented in the scientific literature, with

numerous applications on water, energy, and transport infrastructures (Kabir et al., 2014).

As pointed out by Rowley et al. (2012), each MCA method has theoretical and practical

implications and should be selected after analysis of the decision makers’ need. Rowley

et al. (2012) proposed a classification of MCA methods into two main categories. Type 1

methods are based on a synthetizing criterion (sometimes referred as sustainability in-

dex/score, final preference or composite indicator) which allow positioning of all alter-

natives on a single scale. They include the Weighted Product Model (Bridgman, 1922),

the Weighted Sum Model (Fishburn, 1967), the Analytical Hierarchy Process (AHP) ap-

proach (Saaty, 1980), and the TOPSIS approach (Hwang and Yoon, 1981). Type 1 meth-

ods are compensatory, meaning that low performance with regard to one criterion (e.g.

climate preservation) can be compensated by high performance with regard to another

(e.g. affordability). Type 2 methods are based on a preference relational system that com-

pares the alternatives in a pairwise manner (outranking approach). They include the

Page 25: Shallow co-location of water, sewer and district heating pipesltu.diva-portal.org/smash/get/diva2:1294643/FULLTEXT01.pdf · rankades som det tredje bästa alternativet medan konventionella

12

ELECTRE (Benayoun et al., 1966) and PROMETHEE (Brans and Vincke, 1985)

methods and are non-compensatory.

In a review by Kabir et al. (2014) of 330 multi-criteria analysis studies dealing with in-

frastructure systems, compensatory methods were used in 38% of the studies, non-

compensatory methods in 14%, and 48% of the studies used a combination of two or

more methods. In a recent review by Diaz-Balteiro et al. (2017) of 271 sustainability as-

sessment studies using MCA methods, compensatory methods were used in 83% of the

cases. The two most frequent methods were Analytical Hierarchy Process ‒ AHP (34%)

and Weighted Sum Model ‒ WSM (33%).

Some of the compensatory methods (e.g. WSM) have been recognized as relatively sim-

ple and well understandable making them transparent, applicable, and convenient to en-

gage stakeholders (Lundie et al., 2008; Kabir et al., 2014). Lack of transparency has been

identified by Lai et al. (2008) as one the three shortcomings to address when electing a

MCA method, together with preferential interdependency and double counting. The

main criticism of compensatory MCA methods is their lack of compliance with the

principles of strong sustainability (Rowley et al., 2012; Cinelli et al., 2014). For example,

they could give high preference to alternatives with large environmental losses compen-

sated by large economic profits, while strong sustainability considers that “certain sorts of

natural capital are deemed critical and not readily substitutable by man-made capital” (Munda,

2005). Another criticism of some simple compensatory methods (e.g. WSM) is that they

require an additional step (e.g. sensitivity analysis) to consider uncertainties in the per-

formances of alternatives with regards to the sustainability indicators, while non-

compensatory methods (e.g. ELECTRE) can do so intrinsically (Roy, 2005; Rowley et

al., 2012).

Most compensatory methods require normalization of the indicator values (e.g. cost, en-

vironmental impacts, etc.) to obtain comparable scores before they can be aggregated

into a synthetizing criterion using a preference model. Normalization can be done using

various procedures. The choice of a normalization procedure has implications concern-

ing the meaning of the final aggregated score and stakeholders’ preferences (Rowley et

al., 2012; Pollesch and Dale, 2016). The min-max (Rowley et al., 2012) normalization

scheme is widely used in the literature. Because the latter does not conserve proportion-

ality, it requires, during the weighing process, informing the stakeholders of the range of

performance of the considered alternatives with regard to each indicator (DCLG, 2009;

Rowley et al., 2012). However, this is often not mentioned in publications applying

“min-max” normalization. Other normalization schemes, called ratio normalizations

(Pollesch and Dale, 2016), conserve proportionality but still present some shortcomings.

For example, the inclusion of a new extremum (new alternative with best or worst indi-

cator value for one of the criteria) affect the score of all the alternatives and can modify

Page 26: Shallow co-location of water, sewer and district heating pipesltu.diva-portal.org/smash/get/diva2:1294643/FULLTEXT01.pdf · rankades som det tredje bästa alternativet medan konventionella

13

the original ranking (Pollesch and Dale, 2016). Two options have been identified to

avoid this shortcoming: one is to use an external scale (reference values from regulations

or guidelines) to normalize the indicator values (Pollesch and Dale, 2016); the other is

to calculate the synthetizing criterion using the weighed geometric mean because it

does not require normalization (Ebert and Welsch, 2004).

Page 27: Shallow co-location of water, sewer and district heating pipesltu.diva-portal.org/smash/get/diva2:1294643/FULLTEXT01.pdf · rankades som det tredje bästa alternativet medan konventionella

14

Page 28: Shallow co-location of water, sewer and district heating pipesltu.diva-portal.org/smash/get/diva2:1294643/FULLTEXT01.pdf · rankades som det tredje bästa alternativet medan konventionella

15

3. Methods

3.1. Evaluation of temperature performance

3.1.1. Study site

The study site was a part of the residential area of Tuolluvaara in the town of Kiruna,

Sweden (Figure 4) that was equipped in 2014 with a shallow utilidor system for 9 resi-

dential units. Kiruna is located 150 km north of the Arctic Circle and has a continental

sub-arctic climate. Normal mean temperature is -2○C for the entire year, -14

○C for the

month of January and 12○C for the month of July (SMHI, 2019). The normal period

with snow cover in the town of Kiruna is mid-October to mid-May (SMHI, 2019). The

recommended frost depth in Kiruna for installation of water and sewer pipes under

roads is 2.9 m (VAV, 2001).

Figure 4. Aerial view of the study site in Kiruna, Sweden. The high and low temperature district heat-ing pipes are not shown in the figure.

The district heating house station (Figure 4) is supplied with heat by high temperature

district heating pipes coming from the town’s CHP plant. The heat is transported from

the house station to the residential units using a low temperature district heating

network (Lund et al., 2014). This network consists of supply and return pipes in cross-

: Sanitary sewer : Drinking water : Heat tracing : Future connections

Legend:

Cross-section 1

District heating

house station

Cross-section 2

Page 29: Shallow co-location of water, sewer and district heating pipesltu.diva-portal.org/smash/get/diva2:1294643/FULLTEXT01.pdf · rankades som det tredje bästa alternativet medan konventionella

16

linked polyethylene (PEX) installed in a utilidor made of expanded polystyrene (EPS). It

has the same shape as the heat tracing network shown on Figure 4. This utilidor is

installed in a shallow trench (<1m deep) next to the utilidor containing the gravity

sewer, heat tracing and drinking water pipes (Figure 5a). District heating return water is

circulated in the heat tracing pipe network (from the district heating house station to

each building where it is reinjected into the district heating return pipe). The circulation

of district heating return water in the heat tracing network is maintained by a heat-

tracing pump at the district heating house station. (in red in Figure 5b).

Figure 5. (a, left) Construction picture of the shallow co-location solution at the study site. From left to right: gravity sewer pipe, heat tracing pipe, drinking water pipe, district heating return pipe, district heating supply pipe. (b, right) Cabinet of timer-based regulation system (top) and heat tracing pump (bottom) at the district heating house station. Description of equipment inside the cabinet of the regula-

tion system (from left to right): relay controlling the heat tracing pump, transducer of the PT1000 soil temperature sensor, transducer of the PT1000 heat tracing temperature sensor; power supply, Indus-

truino controller.

3.1.2. Regulation of the heat tracing system

Regulation strategy A. During the winters of 2015-2016 and 2016-2017, the system was

regulated in order to achieve heat tracing temperatures as close as possible to 25○C in

the heat tracing pipe network. Because district heating return temperatures were most

often above this value (35-50○C), a chiller was used just downstream of the heat tracing

pump. It consisted of a plate heat exchanger which dissipated the excess heat by warm-

ing up cold drinking water and discharging it into the sewer network. The heat tracing

pump was turned on / off manually in the autumn / spring, when the soil temperature

at the level of the pipes dropped below / rose above ~1○C.

Page 30: Shallow co-location of water, sewer and district heating pipesltu.diva-portal.org/smash/get/diva2:1294643/FULLTEXT01.pdf · rankades som det tredje bästa alternativet medan konventionella

17

Regulation strategy B. During the winter of 2017-2018 another, more energy and water

efficient, regulation strategy was used. This involved decommissioning the chiller and

operating the heat tracing pump intermittently with the help of a timer system (Figure

5b). The timer, based on an Industruino controller, was programmed according to the

regulation cycle described below.

Figure 6. Target average heat tracing temperature TM as a function of soil temperature TSO. Relationship used in regulation strategy B.

The timer recorded the soil temperature 𝑇𝑠𝑜 provided by a sensor placed just outside the

house station, under the road at the depth of the water /sewer pipes. If 𝑇𝑠𝑜 was higher

than 1○C, the regulation cycle re-started; else, it continued as follows. Based on 𝑇𝑠𝑜, the

target average heat tracing temperature 𝑇𝑀 was determined according to the relationship

shown in Figure 6. Then, the timer operated the pump for one hour and recorded the

heat tracing temperature every minute during that hour. The corresponding hourly

mean temperature 𝑇𝐻 was then calculated. Based on 𝑇𝐻 and 𝑇𝑠𝑜, the timer computed

the period 𝑡𝑜𝑓𝑓 during which the pump should be kept stopped in order to achieve the

average heat tracing temperature 𝑇𝑀 in the utilidor over the regulation cycle. This was

done by solving Equation 1, which is based on Newton’s law of cooling. After a waiting

period of 𝑡𝑜𝑓𝑓, the regulation cycle re-started.

𝑇𝑀 =𝑇𝐻 + 𝜏(𝑇𝐻 − 𝑇𝑠𝑜) (1 − 𝑒−

𝑡𝑜𝑓𝑓

𝜏 ) + 𝑇𝑠𝑜 ∗ 𝑡𝑜𝑓𝑓

𝑡𝑜𝑓𝑓 + 1 (1)

Equation 1 applies to durations expressed in hours and temperatures in degrees Celsius.

𝜏 is the time constant of the cooling problem and depends on the diameter of the heat

0

5

10

15

20

25

30

35

40

-20 -15 -10 -5 0

TM

(○C

)

TSO (○C)

Page 31: Shallow co-location of water, sewer and district heating pipesltu.diva-portal.org/smash/get/diva2:1294643/FULLTEXT01.pdf · rankades som det tredje bästa alternativet medan konventionella

18

tracing pipe, the heat capacity of the heat tracing fluid and the shape and thermal con-

ductivity of the EPS utilidor. A value of 5.55 hours was determined for 𝜏 by fitting an

exponential function on a cooling curve of the heat tracing pipe measured at cross sec-

tion 1. The variables of Equation 1 are illustrated in Figure 7 for an example with heat

tracing temperature variation in the utilidor during the regulation cycle.

Figure 7. Example of heat tracing temperature variation inside the utilidor during the regulation cycle.

The timer adjust toff with the help of Equation 1 to achieve average temperature TM.

3.1.3. Temperature measurements

Pipes and soil temperatures were measured at cross sections 1 and 2 (Figure 4) of the

utilidor system. Cross section 1 (CS1) was on a pipe segment servicing two apartments

referred as apartments 1 and 2, while cross section 2 (CS2) was on a pipe segment ser-

vicing only apartment 2. CS1 was situated under a lawn covered in snow during winter

while CS2 was situated under a carport and was always snow-free. The heat tracing wa-

ter is not re-injected into the district heating return pipe directly at apartment 2 but at

apartment 1 instead. For that reason, the heat tracing pipe is looping inside the utilidor

service connection of apartment 2. Consequently, cross section 2 has two heat tracing

pipes (supply and return of the loop). The geometries of CS1 and CS2 are presented in

Figure 8 together with the locations of temperature sensors. Temperatures of the drink-

ing water pipes (W1, W2), sewer pipes (S1, S2), and heat-tracing pipes (H1, H2) were

measured every four minutes, while the soil temperatures (SO1, SO2) were measured

every hour. Digital temperature sensors GI-695 supplied by Intab were used. The meas-

urement accuracy provided by the manufacturer is ± 0.5°C, in the range -10°C +80°C.

Measurements were logged with the Intab WiSensys system and uploaded for storage on

the Intab cloud. Hourly outside air temperatures were retrieved from the Swedish Me-

teorological and Hydrological Institute (SMHI, 2018).

toff 1h

TM (e.g. 25○C)

TH (e.g. 40

○C)

Page 32: Shallow co-location of water, sewer and district heating pipesltu.diva-portal.org/smash/get/diva2:1294643/FULLTEXT01.pdf · rankades som det tredje bästa alternativet medan konventionella

19

Figure 8. Geometry of cross section 1 (under a lawn) and 2 (under a carport) and location of tempera-ture sensors. Sewer and drinking water pipes are 0.9 meter deep at both cross sections. From construc-tion pictures, the soil type outside the trench was believed to be silty gravely sand at cross section 1, and

crushed rocks at cross section 2.

A four-day experiment was performed during the period 17-21/02/2016 (Paper II) to

investigate the influence of heat tracing temperature on drinking water and sewer pipe

temperatures in the absence of drinking water consumption and sewage discharge

(worst case with regard to freezing and over-heating). During this experiment, different

heat tracing temperatures (15, 20 25, 30, 35°C) were applied at CS1 and CS2 over a pe-

riod of 12 hours. For each heat tracing step, the average heat tracing temperature of the

entire step and the average drinking water / sewer pipe temperatures of the last hour of

the step were computed. For both cross sections, drinking water / sewer temperatures

for the five heat tracing steps were plotted against heat tracing temperature and linear

regressions were determined for these data points.

In the study presented in Paper I, the heat tracing system was operated normally during

a 22 month period from 1/11/2016 to 31/8/2018 and hourly averages were continu-

ously computed and stored for the soil, water pipe, sewer pipe and heat tracing pipe

temperatures at both cross sections. Tenants moved in apartment 1 the 1/11/2017,

meaning that no regular flows of drinking water / sewerage were expected at CS1 be-

fore that date. Whereas after 1/11/2017, regular flows were expected at CS1. For apart-

ment 2, tenants moved in on 1/02/2018, meaning that no regular flows of drinking wa-

ter / sewerage were expected at CS2 before that date. Whereas after 1/02/2018 regular

flows were expected at CS2.

Page 33: Shallow co-location of water, sewer and district heating pipesltu.diva-portal.org/smash/get/diva2:1294643/FULLTEXT01.pdf · rankades som det tredje bästa alternativet medan konventionella

20

3.1.4. Initial model

A two dimensional finite volume model of cross section CS2 was set up using the

thermal modelling software ANSYS CFX. The reason for selecting CS2 was the absence

of an insulating layer on the ground surface (no snow or turf), making the section more

vulnerable to freezing and overheating than CS1 (snow during winter, and turf). The

geometry and material types shown in Figure 8 were used. The right and left boundary

conditions of the model were considered adiabatic, while a geothermal heat flux of 0.08

W/m2 (Bishop et al., 2014) was applied at the bottom of the model. Johansen’s method

(Johansen, 1975) was used to determine the frozen and unfrozen thermal conductivities

of the crushed rocks, assuming a particle density of 2660 kg/m3, a volumetric water

content of 0.06, a porosity of 0.265 (ASRTE, 1999), and a quartz content of soil parti-

cles of 0.45 (Johansen, 1975). The frozen and unfrozen heat capacities of the layer of

crushed rock were calculated with the help of the procedure presented in Andersland

and Ladanyi (1994). Temperature dependent curves of both thermal parameters (thermal

conductivity and heat capacity) were then calculated taking into account gradual freez-

ing of the soil water content between -0.2°C and -0.7°C (as proposed by Geo-slope

(2010) for gravels) and a value of 333.7 kJ/kg for the latent heat of fusion/solidification

of water. These curves were assigned to the crushed rock material in the ANSYS CFX

model of CS2. For the other materials of the cross section, the following thermal con-

ductivities were used: concrete: 1.7 W/m.K; EPS: 0.035 W/m.K; polyethylene pipes:

0.54 W/m.K. For the same materials, the following heat capacities were used: concrete:

1.2 MJ/m3.K; EPS: 0.032 MJ/m3.K; polyethylene pipes: 1.8 MJ/m3.K. For the air inside

the gravity sewer pipe, a Nusselt number of 7 was considered in order to account for

natural convection (Martini and Churchill, 1960). This corresponded to an effective

thermal conductivity value of 0.168 W/m.K.

3.1.5. Model calibration

In all the calibration and validation runs, outside air temperatures measured were applied

to the upper boundary of the model and measured heat tracing temperatures (sensor

H2) were applied to the outside of the heat tracing pipe. The model was calibrated on

the basis of the temperatures measured from 1/11/2016 to 31/7/2017 at sensor loca-

tions SO2, W2 and S2 (Figure 8). To evaluate model performances, the Nash-Sutcliff co-

efficient (R2) of model efficiency (Nash and Sutcliffe, 1970) and the root mean square

error (RMSE) were used. As a first stage, the model was run for different quartz con-

tents of soil particles (initial (0.45), 50% increase, 50% decrease), soil porosities (initial

(0.265), 30% increase, 30% decrease) and volumetric soil water contents (initial (0.06),

50% increase, 50% decrease). Model performance with regard to soil temperature (sensor

SO2) was evaluated for each parameter change. Initial quartz content (0.45), initial po-

rosity (0.265) and 50% increased volumetric water content (0.09) were selected for the

Page 34: Shallow co-location of water, sewer and district heating pipesltu.diva-portal.org/smash/get/diva2:1294643/FULLTEXT01.pdf · rankades som det tredje bästa alternativet medan konventionella

21

crushed rock material because these values yielded the highest model performances. As a

second stage, the model was run for three different thermal conductivity values for the

EPS material (initial (0.035 W/m.K), 30% increase, 50% increase). The value with a 50%

increase (0.053 W/m.K) corresponded to the highest model performance with regard to

drinking water temperature (sensor W2) prediction and was therefore selected. As a third

stage, the model was run for three different effective thermal conductivity values for the

in-sewer air (initial (0.168 W/m.K), 50% decrease, 50% increase). Highest model per-

formance with regard to sewer temperature (sensor S2) prediction was found for the

50% increased value (0.252 W/m.K) which was consequently selected. In the last stage

of the calibration process, the model was run for different positions (θ) of sensor S2 in-

side the sewer (initial 0°, 30°, 60°). θ corresponds to the angle between the pipe bottom

and the sensor location on the pipe wall, as this sensor was laid but not attached inside

the sewer pipe and could lean slightly on the right or left part of the pipe wall. The val-

ue of 60° yielded the highest model performance with regard to sewer temperature

(sensor S2) prediction and was therefore selected.

3.1.6. Model validation

The validity of the model was tested over two consecutive periods. Validation period 1

started on 1/8/2017 and ended on 31/1/2018. The latter date corresponds to the “no-

tenants” case at CS2 when no drinking water or sewage flow was expected. Validation

period 2 started on 1/2/2018 and ended on 31/7/2018. Validation period 2 corresponds

to the “with tenants” case when tenants were living in apartment 2. The model was ex-

pected to perform better during validation period 1 because it was set up and calibrated

for the “no-tenant” case. The calibrated model was run for both validation periods and

the corresponding R2 and RMSE values calculated for the water pipe (W2) and sewer

(S2) temperatures. For soil temperatures (SO2), these values were calculated for the

whole period “1/8/2017-31/1/2018”.

3.1.7. Modelling of exceptionally cold conditions

The historical temperature data (1957-2016) from Kiruna Airport weather station was

examined in order to identify the 31-day and 7-day periods with the lowest average air

temperature. The coldest 31-day period recorded was 13/12/1986 to 12/1/1987 with

an average air temperature of -25.3°C. The coldest 7-day period was included in the

coldest 31-day period and had an average air temperature of -33.8°C. The calibrated

model was then run for the winter of 1986-1987 from 15 October to 15 April (the usu-

al period during which heat-tracing is required). The temperature of the heat-tracing

pipe was set to constantly equal 25°C. The upper heat-tracing pipe was removed from

the model. This was because the stacked heat-tracing pipes are a particularity of cross

section 2 (section 3.1.3), while most of the utilidor contains only one heat-tracing pipe.

Page 35: Shallow co-location of water, sewer and district heating pipesltu.diva-portal.org/smash/get/diva2:1294643/FULLTEXT01.pdf · rankades som det tredje bästa alternativet medan konventionella

22

3.2. Sustainability assessment

The shallow co-location solution for drinking water, sewer and low-temperature district

heating was compared to other, more traditional, technical alternatives by conducting an

integrated sustainability assessment for a representative case study, followed by a sensi-

tivity analysis. All evaluated alternatives were assumed to ensure technical requirements

for provision of water and heating services. The analysis was integrated in the sense that

the compared alternatives were technical options for providing water, sewerage and

heating services to cold climate suburban developments. This was done because the

emergence of shallow co-location solutions, such as the one studied in this thesis, means

that the list of options available for water supply and sewerage (e.g. shallow pipe installa-

tion using low temperature district heating for heat tracing) depends on the option cho-

sen by the district heating (DH) utility (expansion of the DH network with high or low

temperature distribution technology or no expansion). The selection of the most sus-

tainable heating option is also influenced by the technical choices of the water utility as

co-location in a shallow trench will reduce economic and environmental cost for the

expansion of the DH network. These dependencies make separated assessments inade-

quate for assessing the sustainability of shallow co-location alternatives for utility pipes.

3.2.1. Functional unit and system boundaries

The functional unit used for this sustainability assessment was the provision of drinking

water, hot water, sewerage services, and space heating to one household throughout one

year. The assessment covered the production of heat, the transport of heat to the new

suburban area (applies only to DH) and the transport of heat, drinking water and sewage

inside this new area. The transport of drinking water/sewage to/from the new suburban

area as well as drinking water production and sewage treatment were not included in

the assessment. This was because they would be performed in the same way for all the

alternatives compared in this study (i.e. by increased use of the existing pipe networks

and drinking water/wastewater plants). If alternatives with local wastewater treat-

ment/drinking water production were to be compared to the centralized options, the

system boundaries would have needed to be extended. However, these alternatives were

not within the scope of the present study.

3.2.2. Selection of alternatives

For drinking water distribution, the water is distributed with a pressurised network.

However, sewage can be collected either using a gravity sewer network or with a low-

pressure sewer (LPS) system (in Sweden, vacuum sewer systems are very uncommon). In

both cases, the drinking water / sewer pipes have to be protected against freezing. This

can be achieved by laying the pipes below the recommended frost line or by performing

a shallow installation with insulation and electrical or warm water heat tracing.

Page 36: Shallow co-location of water, sewer and district heating pipesltu.diva-portal.org/smash/get/diva2:1294643/FULLTEXT01.pdf · rankades som det tredje bästa alternativet medan konventionella

23

For space heating and hot tap water, there are two options: connecting the new area to

the existing DH network with a high- or low-temperature grid, or not expanding the

network and letting each property owner choose their own heating system. For new

buildings, geothermal and air-to-air heat pumps are the most common alternatives to

DH in Sweden (Swedish Energy Agency, 2015). In the present work, only geothermal

heat pumps were selected as an alternative to district heating because they can provide

comparable thermal comfort, which is not the case for air-to-air heat pumps (Risberg et

al., 2015). These options for provision of sewerage, freeze protection and heat corre-

sponded to 14 possible combinations, as presented in Table 1.

Table 1. Criteria and overall selection scores of fourteen possible combinations of sewer, freeze protec-tion and heating system. HTDH: high temperature district heating, LTDH: low temperature district

heating, GHP: geothermal heat pumps

Combinations Criteria scores Overall

selection

score (SE)

Heating Sewer Freeze protec-

tion

Data availa-

bility

Innovation

level

Synergy

level

HDTH Gravity Deep burial 6 0 2 14

HDTH Gravity Electrical 3 0 4 11

HDTH LPS Deep burial 3 0 2 11

HDTH LPS Electrical 3 0 4 11

LTDH Gravity Deep burial 3 3 2 5

LTDH Gravity Electrical 0 3 4 2

LTDH Gravity Warm water 0 6 6 12

LTDH LPS Deep burial 0 3 2 2

LTDH LPS Electrical 3 3 4 5

LTDH LPS Warm water 0 6 6 12

GHP Gravity Deep burial 6 0 0 18

GHP Gravity Electrical 3 3 0 9

GHP LPS Deep burial 3 3 0 9

GHP LPS Electrical 3 0 0 15

A method was applied to select only five alternatives based on three selection criteria,

including data availability (S1), innovation level (S2) and synergy level (S3). Criteria scores

on a scale of 0-6 were attributed to the combinations as described in the supplementary

material of Paper III. Equation 2 was then used to compute the overall selection scores

(SE) with 𝑆2 and 𝑆3 being mid-range values of 𝑆2 and 𝑆3 scores (3 for both).

𝑆𝐸 = 𝑆1 + 2|𝑆2 − 𝑆2| + 2|𝑆3 − 𝑆3| (2)

Page 37: Shallow co-location of water, sewer and district heating pipesltu.diva-portal.org/smash/get/diva2:1294643/FULLTEXT01.pdf · rankades som det tredje bästa alternativet medan konventionella

24

The overall selection score was structured to attach importance to combinations with

good data availability, low or high innovation level and low or high synergy level. This

was done to favour clear comparisons between traditional and innovative alternatives as

well as separated and integrated approaches. The five combinations with the highest se-

lection scores (in bold in Table 1) were selected as alternatives for the sustainability as-

sessment.

3.2.3. Case description

The residential area Repisvaara South II (Figure 9) was selected for assessing the sustain-

ability indicators (e.g. costs, environmental impacts, failure rates; as described in 3.2.4)

for the five different alternatives. The residential area is a new suburban development

planned for a currently forested area 2 km south of the town centre of Gällivare in

Northern Sweden. It comprises 7 multi-storey buildings with 20 apartments and 71 sin-

gle family homes corresponding to 211 residential units (~420 inhabitants) in total. The

recommended frost depth in Gällivare for installation of water and sewer pipes under

roads is 2.6 m (VAV, 2001).

Figure 9. Map of Repisvaara South II residential area. Source: Gällivare municipality.

Based on Swedish building regulations (Boverket, 2016), the annual heat demand was

estimated at 16900 kWh for single family homes (130 m2) and 8050 kWh for apart-

ments (70 m2). Based on average water use per person provided by the Swedish Water

and Wastewater Association (SWWA, 2016), daily water consumption was estimated at

405 L for single family homes (2.7 people) and 272 L for apartments (1.6 people).

Page 38: Shallow co-location of water, sewer and district heating pipesltu.diva-portal.org/smash/get/diva2:1294643/FULLTEXT01.pdf · rankades som det tredje bästa alternativet medan konventionella

25

A pre-design of the heat and water services provision system for the residential area was

performed for the five alternatives considered. This was done in order to obtain an in-

ventory of the elements forming each alternative (e.g. length of pipes, number of

pumps, etc.). Further information concerning the pre-design stage is available in Paper

IV. The five alternatives, as applied to Repisvaara south II, are presented below.

Alternative 1. A gravity sewer system is used to transport the sewage from the residential

units to the existing sewer network (connection point in area B1, Figure 9). It includes

one pumping station in area A4 (Figure 9). Drinking water is conveyed from the exist-

ing network (connection point in B1, Figure 9) to the residential units through pressur-

ised pipes. Sewer and drinking water pipes are laid below the frost depth (Figure 10a).

Heat for space heating and hot tap water is produced from biomass and peat at the CHP

plant of Gällivare and is transported to Repisvaara South II via the existing DH net-

work. Heat is distributed inside the residential area through high-temperature DH pipes

(90-60°C) made of steel. Each house is equipped with a substation including two heat

exchangers and circulation pumps. The trench layout for DH is presented in Figure 10b.

Alternative 2*. Sewer and drinking water networks have the same shape and compo-

nents as in alternative 1 but the pipes are laid at a depth of 1.3 m in an insulated utilidor

heat traced with a warm water (20 to 25°C) circulation pipe, above the ground water

level in a well-drained trench. Heat distribution inside the neighbourhood is performed

by a low temperature DH system (30-60°C) with pipes in cross-linked polyethylene

(PEX), placed in an insulated utilidor. This utilidor is in the same shallow trench as the

water-sewer utilidor (Figure 10c). The low temperature DH system is supplied with heat

from the existing DH network via a heat exchanger installed in a house station in area

B1 (Figure 9). Alternative 2* corresponds to the shallow co-location solution tested in

Kiruna in Papers I and II.

Alternative 3*. The same DH, drinking water and freeze protection systems as in alterna-

tive 2* are used. Sewage is conveyed from the residential units to the existing network

with a Low Pressure Sewer (LPS) system instead of a gravity system. A grinder pump

station at each single family home and multi-storey building discharges the sewage into

a pressurised network of small diameter pipes. The trench layout is the same as in alter-

native 2* (Figure 10c).

Alternative 4. The same sewer and drinking water systems as in Alternative 1 are used.

Gravity sewer and drinking water pipes are installed at a depth of 2.4 m for frost protec-

tion (Figure 10a). Heat provision is performed by geothermal heating systems situated in

each single family home and multi-storey building. The geothermal heating systems in-

clude a brine-to-water heat pump, vertical collectors and 200 m deep boreholes.

Page 39: Shallow co-location of water, sewer and district heating pipesltu.diva-portal.org/smash/get/diva2:1294643/FULLTEXT01.pdf · rankades som det tredje bästa alternativet medan konventionella

26

Alternative 5. The heating system is the same as in Alternative 4 (geothermal heat pumps

with vertical collectors). As in alternative 3*, the sewage is transported from the residen-

tial units to the existing network using an LPS system. The drinking water network is

the same as in the other alternatives. The LPS and drinking water pipes are laid in a 1 m

deep trench in a box-shaped frost shield filled with 0-8 mm crushed rocks and heat

traced with an electric cable (Figure 10d).

Figure 10. Typical trench layout in Repisvaara South II for a) gravity sewer and drinking water (Alter-natives 1 and 4); b) high temperature DH (Alternative 1); c) low temperature DH, drinking water and

gravity or LPS sewer with warm water heat trace (Alternatives 2* and 3*); d) LPS sewer and drinking

water with electrical heat trace (Alternative 5).

3.2.4. Criteria and associated indicators

A set of seven sustainability criteria (C1-C7) was used to compare the system alterna-

tives. The criteria set was built by selecting, among the list defined by Hellström et al.

(2000), the criteria that were expected to be significantly affected by the choice of pipe

system for water, sewage and heat transport. At least one criteria was selected in each of

the categories proposed by Hellström et al. (2000), i.e. environment, economy, social,

health & safety and technical. Measurable indicators were also selected for each criterion

and are presented below, together with the methods used for their evaluation.

C1. Energy efficiency. The cumulative exergy demand of energy carriers (𝐼1) as defined by

(Bösch et al., 2007) and expressed in megajoules per functional unit was used as an indi-

cator of energy efficiency. Cumulative exergy demand was used instead of the cumula-

tive energy demand (VDI, 1997; Frischknecht et al., 2015) in order to account for the

difference in quality between shallow geothermal energy (low temperature heat) and

Page 40: Shallow co-location of water, sewer and district heating pipesltu.diva-portal.org/smash/get/diva2:1294643/FULLTEXT01.pdf · rankades som det tredje bästa alternativet medan konventionella

27

the other primary energy sources (e.g. hydropower, nuclear, fossil, biomass, wind, solar)

that can generate high temperature heat, work or electricity.

C2. Climate preservation. The global warming potential (𝐼2) as defined by the interna-

tional panel on climate change (IPCC, 2007), and expressed in kilograms CO2 equiva-

lent emitted per functional unit, was used as an indicator of climate preservation.

C3. Material efficiency. The abiotic depletion potential of elements (non-fossil) resources

(𝐼3) as defined by van Oers et al. (2002), and expressed in kilograms antimony equivalent

extracted per functional unit, was used as an indicator of the material efficiency criteri-

on.

A life cycle impact assessment (ISO, 2006) was performed for each alternative to evalu-

ate the three environmental indicators I1-I3. Production, transport, construction, mainte-

nance and use phases of the elements forming each alternative (e.g. pipes, pipe insula-

tion, pumps, heat pumps) were covered by the assessment. Methods and input data used

to perform the life cycle impact assessment are presented in Paper III and IV.

C4. Affordability. The total cost per functional unit 𝐼4 was used as an indicator of afforda-

bility. 𝐼4 includes the amortisation of investments, interest payments and operation &

maintenance costs related to each alternative, independently of who should pay these

expenses (household, water utility or energy utility). Methods and input data used to

evaluate I4 are presented in Paper III and IV. For investments, an interest rate of 4% was

assumed, which is common for long-term investment decisions in the Swedish water

sector (Kärrman et al., 2012; Nacka Municipality., 2012).

C5. User friendliness. The number of actions to be performed annually by the users in

order to maintain the system (𝐼5), was used as an indicator of the user friendliness of

each alternative. The actions considered were: a) organising a yearly check-up of the dis-

trict heating sub-station; b) organising a yearly check-up of the geothermal heat-pump;

c) monitoring the screen/warning lights of the geothermal heat pump and taking action

if a fault appears; d) monitoring the warning light of the LPS and calling the water utili-

ty if the light is red.

C6. Safety for workers. The frequency of work accidents (accident/worker/year) that can

be expected with each alternative (𝐼6) was used as the indicator of the workers’ safety

criterion. The average frequency of work accidents in Sweden in the water and heat

networks construction sector was calculated for the years 2012, 2013, 2015 and 2016

based on the data collected by the Swedish Work Environment Authority (SWEA,

2018). This calculated value was attributed to the alternatives using deep pipe installation

for the 𝐼6 indicator. For the other alternatives, the same procedure and in-data were

Page 41: Shallow co-location of water, sewer and district heating pipesltu.diva-portal.org/smash/get/diva2:1294643/FULLTEXT01.pdf · rankades som det tredje bästa alternativet medan konventionella

28

used, but accidents due to material collapse/fall and falls of persons from a height were

excluded from the calculations.

C7. Reliability. Two indicators were used to evaluate this criterion. The anticipated fail-

ure rate of the sewer network 𝐼7𝑎 expressed in failure/connection/year was the first in-

dicator. The rate of blockages in main and lateral sewers in Gällivare between 2013 and

2015 (VASS, 2017) was used as an estimate of 𝐼7𝑎 for the alternative with gravity sewer.

The rate of failure of grinder pumps and LPS pipes observed in 29 Swedish municipali-

ties between 1991 and 1998 (Lindqvist et al., 2000) was used as an estimate of 𝐼7𝑎 for

alternatives with LPS. 𝐼7𝑎 does not correspond to the failure rate experienced by the

households but is an indicator of how often the water utility has to perform re-

pairs/unplanned maintenance on the system.

The anticipated rate of failure of the heating system 𝐼7𝑏 (number of unmet heat demand

events per household per year) was the second reliability indicator. Frequency of failures

reported to insurance companies in Sweden (Haglund Stignor et al., 2012) for geo-

thermal heat pumps was used as an estimate of 𝐼7𝑏 for these systems. 𝐼7𝑏 was evaluated

for the district heating options based on typical failure rates for pre-insulated pipes

(Åkerström, 2004) and taking into account the shape of the networks. These calculations

are presented in the supplementary material in Paper III.

3.2.5. Calculation of sustainability scores

The weighted sum model (WSM) was used to aggregate the indicator values of each

alternative into an overall sustainability score on the basis of weights given by a refer-

ence group. The motivation for selecting the WSM multi-criteria method is that it is a

transparent, well-proven and easily understandable technique (Kabir et al., 2014), which

is valuable for engaging stakeholders (Lundie et al., 2008). It is also applicable when all

indicators are quantitative, which was the case in this thesis (see 3.2.4).

Weights were assigned to the criteria during a “budget allocation” workshop (Nardo et

al., 2005) in which seven stakeholders from the town of Gällivare participated. Three of

the stakeholders were from the municipal water utility, one from the district heating

utility, one from the municipal urban planning unit and two from the main housing

company in the town. System boundaries, alternatives and criteria were first described

and the stakeholders were then individually asked to distribute a budget of 100 points

across the seven criteria. A discussion was held later to try to reach a consensus within

the reference group with regard to the allocation of the points budget. Because no con-

sensus was reached, the average point distribution of each sub-group (water, energy,

planning and housing) was calculated using the arithmetic mean. The energy stakehold-

er did not provide a point distribution during the workshop and preferred instead to

rank the different criteria. This ranking was converted to a point repartition by using the

Page 42: Shallow co-location of water, sewer and district heating pipesltu.diva-portal.org/smash/get/diva2:1294643/FULLTEXT01.pdf · rankades som det tredje bästa alternativet medan konventionella

29

average number of points given by the other sub-groups for each ranking. The average

point distribution of the reference group was then determined by computing the arith-

metic mean of the point distributions of each sub-group. The weight of each criterion

(𝑤𝑗) was later calculated by dividing its number of points by 100, giving weights values

between 0 and 1.

Normalization of the indicator values is necessary when using the WSM method in or-

der to calculate a sum that is meaningful. The “smaller-the-better” ratio normalization

scheme defined by Pollesch and Dale (2016) was used. This normalization scheme con-

serves proportionality between indicator values and gives values in the range ]0;100]

where 100 indicates the highest performance with regard to the considered criteria.

Each sustainability indicator was normalized using Equation 3, where min( 𝐼𝑗 ) is the

minimum of 𝐼𝑗 across the five alternatives and 𝐼𝑗∗ is the normalized value of 𝐼𝑗.

𝐼𝑗∗ = 100 ×

min ( 𝐼𝑗 )

𝐼𝑗 (3)

The calculation of the overall sustainability scores 𝑆𝑎 for each alternative according to

the WSM method was performed using Equation 4. Note that for criteria C1 to C6,

normalized indicator values 𝐼1∗ to 𝐼6

∗ were directly used as criteria scores while, for C7,

the arithmetic mean of 𝐼7𝑎∗ and 𝐼7𝑏

∗ was used.

𝑆𝑎 = ( ∑ 𝑤𝑗 𝐼𝑗∗

6

𝑗=1

) + 𝑤7

(𝐼7𝑎∗ + 𝐼7𝑏

∗ )

2 (4)

3.2.6. Sensitivity analysis

The method developed by Triantaphyllou (2000) was used to evaluate the sensitivity of

the sustainability ranking to changes in criteria weights. The principle of the method is

to determine, for each criterion 𝐶𝑗, the minimum change in the weight 𝑤𝑗 required to

change the top-ranked alternative. The stability of the sustainability ranking in the face

of changes in a number of input parameters was also assessed. This was done manually

by changing parameter values in a step-wise manner until the top-ranked alternative

would change. The parameters assessed were: urban density, heat demand, failure rates for

district heating and geothermal pumps, gravity sewer blockage rate, coefficient of per-

formance (COP) of geothermal heat pumps, coal fraction of the electricity mix, biomass

fraction of the district heating fuel mix, geothermal fraction of the LTDH fuel mix, lin-

ear cost of deep trench with water and gravity sewer pipes, lifespan of geothermal heat

pumps, marginal costs of district heating, and electricity price. These parameters were

selected because they were believed to be uncertain and were related to highly weighted

criteria or because they represented a specific context (e.g. climate, energy mix) of the

Page 43: Shallow co-location of water, sewer and district heating pipesltu.diva-portal.org/smash/get/diva2:1294643/FULLTEXT01.pdf · rankades som det tredje bästa alternativet medan konventionella

30

case study. For the parameter “geothermal fraction in LTDH mix”, the environmental

impacts calculated in Paper VI and the cost provided by the European Geothermal En-

ergy Council (2014) for geothermal DH were used.

As part of the sensitivity analysis, the impact on the ranking of using the “min-max”

normalization scheme (see Rowley et al. (2012) for equations) was investigated. The

ranking was also determined using the weighed geometric mean (Equation 5) which

does not require normalization of the indicators.

𝑆𝑔 = (∏ 𝐼𝑗

𝑤𝑗

6

𝑗=1

) (√𝐼7 𝐼8)𝑤7

(5)

Page 44: Shallow co-location of water, sewer and district heating pipesltu.diva-portal.org/smash/get/diva2:1294643/FULLTEXT01.pdf · rankades som det tredje bästa alternativet medan konventionella

31

4. Results

4.1. Temperature performance

4.1.1. Measured pipe temperatures

The hourly drinking water pipe temperatures measured at the pilot site of Kiruna (Fig-

ures 11a and 11c) remained above 0○C during the observation period when no tenant

lived in the flats, but exceeded 15○C (to the right of dashed line) during 100 hours (fre-

quency of 1.2%) at cross section 1 and 47 hours (frequency of 0.4%) at cross section 2.

These deviations occurred mostly during the summer of 2017 at cross section 1 and

during the winter of 2017-2018 at cross section 2, usually at the beginning of the heat

tracing cycles of regulation strategy B. However, drinking water pipe temperatures did

not exceed 17○C during this period. The major mode (most frequent value) of drinking

water pipe temperature for the “no tenant” case was 13○C at cross section 1 and 11.5

○C

cross section 2. Hourly sewer pipe temperatures (Figures 11b and 11d) did not drop be-

low 0○C either during the observation periods when no tenants lived in the flat, at any

of the cross sections. The major mode of the sewer pipe temperature was 5○C at cross

section 1 and 6○C at cross section 2.

Figure 11. Histograms of measured water (a,c) and sewer (b,d) pipe temperatures at cross sections 1 (a,b) and 2 (c,d) for the period when tenants were not living in the serviced apartments: 1/11/2016-31/10/2017 and 1/11/2016-31/1/2018, respectively. All measurements from the period 20/10-7/11/2017 were excluded (improvement works on the system). In (d), period 24/12/2016-17/2/2017 was also excluded (erroneous measurements due to air infiltration in the sewer caused by the measure-

ment system). Dashed line represents the 15○C upper threshold for comfortable drinking water.

Page 45: Shallow co-location of water, sewer and district heating pipesltu.diva-portal.org/smash/get/diva2:1294643/FULLTEXT01.pdf · rankades som det tredje bästa alternativet medan konventionella

32

For the case with tenants, hourly drinking water pipe temperature was also continuously

positive for both cross sections during the corresponding observation period (Figures

12a and 12c). The drinking water pipe temperature exceeded 15○C during 589 hours

(frequency of 8.2%) at cross section 1 and 38 hours (frequency of 0.7%) at cross section

2.These deviations occurred during the summer of 2018. Soil temperatures during the

summer of 2018 were in the range 10-17○C. The major mode of drinking water pipe

temperature was 8.1○C for cross section 1 (colder than in the case without tenants) and

13.1○C for cross section 2. Sewer temperatures did not drop below 0

○C during the ob-

servation period with tenants living in the apartments (Figures 12b and 12d). The major

mode of the sewer temperature was 11.6○C at cross section 1 and 13.6

○C at cross sec-

tion 2, significantly warmer than in the case without tenants. At cross section 1 which

serviced two apartments, the temperature histograms were unimodal (Figures 12a and

12b), while at cross section 2 which serviced one apartment, the same histograms were

bimodal (Figures 12c and 12d). This could be explained by the fact that no flow condi-

tions (tenants in holiday or away for the week end) are more likely to occur in sections

servicing one apartment than in the ones servicing two apartments. The minor mode of

the drinking water temperature at cross section 2 was 7.1○C (Figure 12c), which is

comparable to the mode observed at cross section 1 (Figure 12a). The minor sewer tem-

perature mode at cross section 2 was 7.6○C (Figure 12d).

Figure 12. Histograms of measured water (a,c) and sewer (b,d) pipe temperatures at cross section 1 (a,b) and 2 (c,d) for the period when tenants were living in the serviced apartments: 1/11/2017-31/8/2018 and 1/2/2018-31/8/2018, respectively. All measurements from the period 20/10-7/11/2017 were ex-

cluded (improvement works on the system). Dashed line represents the 15○C upper threshold for com-

fortable drinking water.

Page 46: Shallow co-location of water, sewer and district heating pipesltu.diva-portal.org/smash/get/diva2:1294643/FULLTEXT01.pdf · rankades som det tredje bästa alternativet medan konventionella

33

4.1.2. Impact of heat tracing and soil temperature

Linear relations between pipe temperature (water, sewer) and heat tracing temperature

for cross section 2 were derived from a 4 days experiment, presented in Paper II, when

there were no tenants in the serviced apartment. The soil temperature during this ex-

periment was not measured. The goodness of fit was high, with coefficients of determi-

nation of 0.99 for both the water and sewer pipes. These relations are depicted by the

black lines in Figures 13a and 13b. In Figure 13, hourly data points measured in Paper I

during a 6.5 month period in the winter of 2016-2017 are also plotted. During this pe-

riod, tenants were not living in the apartment serviced by cross section 2 (as in Paper II).

The soil temperature was this time measured during the experimental period and is in-

dicated with a colour scale for each data point in Figure 13.

The linear relations found in Paper II indicated that drinking water pipe temperature

was more affected than sewer temperature by changes in heat tracing temperature. A rise

in heat tracing temperature from 20 to 30

○C increased drinking water pipe temperature

by 3.4○C (from 9.6 to 13

○C) and sewer temperature pipe by 2.4

○C (from 4.8 to 7.2

○C).

Moreover, the superposition of these relations with the data points of Paper I indicated

that the soil temperature was between 0 and -2○C during the 4 days experiment pre-

sented in Paper II. The validity of the linear relations presented in Figure 13 (black lines)

is therefore limited to the [0;-2○C] soil temperature range.

The influence of soil temperature on the drinking water pipe and sewer temperatures is

seen in Figures 13a and 13b. Overall, the main dot colour transitions from yellow

(1.5○C) to dark blue (-6

○C) when reading the figure from top to bottom. However,

parts of the dataset do not follow this trend, in particular the data marked with ellipses

A, B and C in Figure 13. Dots inside ellipses A and B correspond to drinking water use

and corresponding sewage discharges caused by an automatic device (NASA orbital

shower) inside the serviced flat. Data points inside ellipse C correspond to erroneous

measurements caused by infiltration of cold outside air inside the sewer along the cable

of the temperature sensor. The denser part of the point clouds with a coherent colour

gradation indicates that, at cross section 2, a drop in soil temperature from 1 to -5○C de-

creased the water pipe temperature by 3.5○C (13.5 to 10

○C for heat tracing temperature

of 25○C) and the sewer pipe temperature by 5

○C

(9 to 4

○C for heat tracing temperature

of 25○C). This holds for the steady thermal state where water pipe and sewer tempera-

tures had stabilized after a sufficient period without water consumption / sewage dis-

charge.

Page 47: Shallow co-location of water, sewer and district heating pipesltu.diva-portal.org/smash/get/diva2:1294643/FULLTEXT01.pdf · rankades som det tredje bästa alternativet medan konventionella

34

Figure 13. Drinking water (a) and sewer (b) pipe temperature plotted against heat tracing temperature at cross section 2. Black lines correspond to the relation found in Paper II (17-21/2/2016). Data points represent hourly averages measured from 1/11/2016 to 15/5/2017 (first winter of experiment in Paper I, heat tracing system activated, no tenants in the serviced flat) and are coloured according to the soil temperature (measured 20 cm outside the utilidor at the level of the pipes). Ellipse A: data points meas-ured during transient thermal state induced by drinking water consumption; Ellipse B: data points measured during transient thermal state induced by sewage discharge; Ellipses C: erroneous measure-

ments caused by air infiltration into the sewer along the cable of the temperature sensor.

(a)

(b)

A

B

C

Page 48: Shallow co-location of water, sewer and district heating pipesltu.diva-portal.org/smash/get/diva2:1294643/FULLTEXT01.pdf · rankades som det tredje bästa alternativet medan konventionella

35

4.1.3. Model performances

In Paper I, the finite volume thermal model of cross section 2 was calibrated over a 9-

month period. Its validity was assessed over a 6-month period without regular water

consumption (no tenants in serviced flat) and another 6-month period with regular wa-

ter consumption (tenants living in serviced flat). The performance of the model is

shown in Table 2 in terms of R2 and RMSE values as well as in Figure 14 in term of

modelling errors throughout the entire experimental period (calibration and validation

periods).

The model showed a high performance regarding soil temperature prediction, with an

R2 value of 0.97 during calibration and 0.92 during validation (the distinction between

validation periods 1 and 2 was not made for soil temperature since it was not expected

to be affected by drinking water/sewage flows). However, the model underestimated soil

temperature by more than 4○C during 20 days in January and February 2018 (Figure

14a).

Table 2. Nash-Sutcliff coefficient (R2) and Root Mean Square Error (RMSE) for soil, drinking water pipe and sewer pipe temperatures during calibration period, validation period 1 (no tenants in serviced

flat) and validation period 2 (tenants in serviced flat).

Calibration period

1/11/16-31/7/17

Validation period 1

1/8/17-31/1/18

Validation period 2

1/2/18-31/7/18

Soil temperature R2=0.97

RMSE=0.94○C

R2=0.92

RMSE=2.00○C

Water pipe temperature R2=0.61

RMSE=1.07○C

R2=0.70

RMSE=1.84○C

R2=0.50

RMSE=1.92○C

Sewer pipe temperature R2=0.60

RMSE=2.27○C

R2=0.82

RMSE=1.69○C

R2=-0.57

RMSE=3.78○C

Both drinking water pipe and sewer temperatures could be explained fairly well by the

model (R2 values of 0.60 and 0.61 over the calibration period). However, modelling er-

rors during the calibration period were considerably higher for the sewer temperature

than for the drinking water pipe temperature (see Figure 14b, 14c and RMSE values in

Table 2).

Temperatures of both pipes were well predicted by the model during the validation pe-

riod 1 (R2 values of 0.70 for drinking water pipe and 0.82 for sewer pipe, higher than

during calibration). This can be attributed to the very good fit of the soil temperature

model during September and October 2017 (Figure 14a). For drinking water tempera-

ture, the modelling error was however more frequently outside the [-2;2○C] range dur-

ing validation period 1 than during the calibration period. During the validation period

Page 49: Shallow co-location of water, sewer and district heating pipesltu.diva-portal.org/smash/get/diva2:1294643/FULLTEXT01.pdf · rankades som det tredje bästa alternativet medan konventionella

36

2, the model showed poor performances regarding temperature predictions for both

pipes (see low R2 values in Table 2 and large modelling errors in Figures 14b and 14c).

This can be explained by the water consumed by the tenants in apartment 2, which

generated drinking water and sewage flows in the pipes at cross section 2. These flows

were not taken into account in the thermal model.

Figure 14. Variations of modelling error for soil (a), drinking water pipe (b) and sewer pipe (c) temper-

atures during calibration and validation periods.

4.1.4. Modelled pipe temperatures under exceptionally cold conditions

The thermal model calibrated on cross section 2 was used to simulate soil, drinking wa-

ter and sewer temperatures during the period 15/10/1986-15/4/1987 (winter with

coldest month and coldest week recorded since 1957 in the town of Kiruna where the

study site is located). The outputs (water pipe, sewer pipe and soil temperatures) and in-

puts (outside air and heat tracing temperatures) of the simulation are presented in Figure

15. The results indicated that the drinking water pipe temperature would have remained

positive during the extraordinary cold winter of 1986-1987. The simulation also indi-

cated that the sewer pipe temperature would have been below 0○C during 14 days and

-8

-4

0

4

8

◦C

(a) Modelling error for the soil temperature (Tmodelled - Tmeasured)

Calibration Validation

-8

-4

0

4

8

◦C

(b) Modelling error for the water pipe temperature (Tmodelled - Tmeasured)

Calibration

Validation 1

Validation 2

-8

-4

0

4

8

◦C

(c) Modelling error for the sewer pipe temperature (Tmodelled - Tmeasured)

Calibration Validation 1 Validation 2

Page 50: Shallow co-location of water, sewer and district heating pipesltu.diva-portal.org/smash/get/diva2:1294643/FULLTEXT01.pdf · rankades som det tredje bästa alternativet medan konventionella

37

reached a minimum of -4.5○C. Moreover, the minimum soil temperature was estimated

at -20.8○C during the simulation period. The results shown in Figure 15 apply for the

no-flow case (drinking water or sewage flow) and for a cross section equivalent to cross

section 2 (no snow cover) with one heat tracing pipe (see section 3.1.7).

Figure 15. Simulated drinking water pipe, sewer pipe and soil temperatures for the period 15/10/1986-15/04/1987. Model inputs (outdoor air and heat trace temperatures) are also represented

for the same period.

4.2. Sustainability

4.2.1. Indicator values

Five heating and water services provision alternatives for the residential area of Repis-

vaara South II in Gällivare, Sweden were evaluated with respect to eight sustainability

indicators (Paper III). Alternative A2* corresponds to the shallow co-location solution

installed in Kiruna and evaluated in relation to temperature performance (Paper I and

II). Alternative A3* uses the same shallow pipe co-location solution as A2* but with a

low pressure sewer instead of gravity sewer. The indicator values obtained are presented

in Table 3. I1, I2 and I3 are environmental indicators. I4 is an economic indicator, I5 a so-

cial indicator and I6 a health and safety indicator. Finally, I7a and I7b are technical indica-

tors. Note that the total costs (I4), expressed in €/year/household, do not represent what

the household needs to pay yearly for water and heating services (see section 3.2.4).

The life cycle impact assessment showed that the use phase of the heating system had

the largest contribution to the cumulative exergy demand (78-98%) and global warming

potential (65-98%) of the alternatives. For the abiotic depletion potential of elements,

the construction phase of the heating system had the highest contribution to the indica-

tor values (82-91%).

-40-35-30-25-20-15-10-505

1015202530

15-Oct-86 15-Nov-86 15-Dec-86 15-Jan-87 15-Feb-87 15-Mar-87

Dai

ly A

ver

age

( ◦C

)

Water (Output) Sewer (Output) Soil (Output) Air (Input) Heat trace (Input)

Page 51: Shallow co-location of water, sewer and district heating pipesltu.diva-portal.org/smash/get/diva2:1294643/FULLTEXT01.pdf · rankades som det tredje bästa alternativet medan konventionella

38

Table 3. Indicator values of the five alternatives studied for the residential area Repisvaara South II. G: gravity sewer; LPS: low-pressure sewer; HTDH: high-temperature district heating; LTDH: low-

temperature district heating; GHP: geothermal heat pump. * designates alternatives where pipes for wa-ter services and district heating are co-located in a shallow trench above the frost depth. Indicator I3 co-

vers only the extraction of elements (non-fossil abiotic resources) from the environment.

Alternative

Indicator

A1: G

HTDH

A2*:

G LTDH

A3*:

LPS LTDH

A4: G

GHP

A5: LPS GHP

I1: Cumulative Exergy Demand [GJ/year/household] 67 65 65 24 28

I2: Global Warming Potential

[tCO2eq/year/household] 1.5 1.4 1.4 0.2 0.2

I3: Abiotic Depletion Potential [gSbeq/year/household] 0.9 1.6 1.6 2.5 2.5

I4: Total cost [€/year/household] 730 620 650 910 880

I5: Number of actions to be performed by tenants 1 a) 1 a) 2 a) d) 2 b) c) 3 b) c) d)

I6: Work accident frequency

[accident/worker/year] 0.016 0.012 0.012 0.016 0.012

I7a: Failure rate - sewer

[failure/year/connection] 0.03 0.03 0.11 0.03 0.11

I7b: Failure rate - heating [failure/year/household] 0.16 0.21 0.21 0.02 0.02

a. Organise a yearly check-up of the district heating sub-station; b. Organise a yearly check-up of geo-

thermal heat-pump; c. Monitor the screen/warning lights of the geothermal heat pump and take action

if a fault appears; d. Monitor the warning light of the LPS and call the water utility if the light is red.

4.2.2. Criteria scores

The criteria scores, presented graphically in Figure 16 and numerically in Table 5, were

obtained by normalization of the indicator values presented in Table 3. With the nor-

malization scheme used in this study, an alternative with a score of 100 corresponds to

the highest performance with regard to the considered criterion (e.g. affordability),

meaning that the alternative had the lowest value for the indicator of that criteria (e.g.

lowest total cost). Because the normalization scheme conserved proportionality, a score

of 25/100 means that the alternative had an indicator value four times as large as the

lowest indicator value for that criterion (e.g. was four times more expensive than the

cheapest alternative). A score strictly equal to zero cannot occur as it corresponds to an

indicator value equal to infinity.

Page 52: Shallow co-location of water, sewer and district heating pipesltu.diva-portal.org/smash/get/diva2:1294643/FULLTEXT01.pdf · rankades som det tredje bästa alternativet medan konventionella

39

Figure 16. Criteria scores for the five alternatives studied. Scale from 0 (low performance, centre) to 100 (high performance, edge). Abbreviations: G: gravity sewer; LPS: Low pressure sewer; HTDH: high

temperature district heating; LTDH: low temperature district heating; GHP: geothermal heat pump. * designates alternatives where pipes for water services and district heating are co-located in a shallow trench above the frost depth.

Page 53: Shallow co-location of water, sewer and district heating pipesltu.diva-portal.org/smash/get/diva2:1294643/FULLTEXT01.pdf · rankades som det tredje bästa alternativet medan konventionella

40

The shallow co-location alternatives with low temperature district heating (A2* and

A3*) were found to be considerably less energy efficient and climate-preserving than

the alternatives with geothermal heat pumps (A4 and A5). This was because the heat

pumps were supplied with only 25% of the residential heat demand in the form of elec-

tricity, produced in Sweden with a low carbon footprint (mainly from hydropower and

nuclear power). The other 75% corresponded to low temperature geothermal heat of

negligible exergy content. With district heating, 100% of the residential heat demand

was covered by the combustion of high exergy fuels (peat and wood chips) at the dis-

trict heating plant Gällivare. As regards material efficiency, the alternatives with low

temperature district heating A2* and A3* showed significantly lower performances than

the traditional alternative A1 with high temperature district heating and deep buried

water / sewer pipes. This was mainly due to more resources needed for the extra heat

exchanger and circulation pumps required for reduction of the temperature when

switching from high to low district heating temperatures.

The shallow co-location solutions with low temperature district heating (A2* and A3*)

were 11 to 15% cheaper than alternative A1 (traditional district heating and deep wa-

ter/gravity sewer pipes) and 26 to 32% cheaper than the alternatives with geothermal

heat pumps (A4 and A5). This was due to the reduction in excavation costs offered by

shallow co-location of the pipes and the high construction costs of geothermal heating

systems in comparison with district heating. A2* and A1, both including district heating

and gravity sewer, were assessed to be more user friendly than the other alternatives be-

cause they required the tenants to only organise a yearly check- up of the district heat-

ing sub-station. The alternatives with geothermal heat pump and/or LPS grinder pump

were estimated to demand more care from the tenants for maintenance of the system

because they required one to two more actions per year (Table 3).

The shallow co-location solutions A2* and A3*, as well as alternative A5 with geo-

thermal heat pumps and low pressure sewer (LPS), were found to be 25% less unsafe for

workers than the other alternatives because they do not involve work around/in deep

trenches. All alternatives corresponded however to a low work accident frequency (12 to

16 accident/year/1000 workers). As regards reliability, alternative A2* had a considerably

lower score than alternative A4 with geothermal heat pump and gravity sewer. This was

mainly due to the district heating network section of 2.5 km connecting the newly

built area to the town centre of Gällivare. Any failure on this section would put at risk

the provision of heat to all the households. The reliability score of the alternative A3*,

with district heating and low pressure sewer, was even lower due to the higher failure

rate per connection found for grinder pumps used in LPS systems than for the gravity

sewer network.

Page 54: Shallow co-location of water, sewer and district heating pipesltu.diva-portal.org/smash/get/diva2:1294643/FULLTEXT01.pdf · rankades som det tredje bästa alternativet medan konventionella

41

4.2.3. Criteria weights

The point distributions given by the seven stakeholders during the budget allocation

workshop are presented in Table 4. The calculated mean point distribution of each sub-

group is also presented. Energy efficiency was the criterion for which sub-group mean

values were most spread (from 19 to 33 points) and corresponded to a standard devia-

tion of 5 points. Reliability and affordability were the criteria with second and third

most spread sub-group mean values, corresponding to a standard deviation of 4 points.

The mean point distribution of the entire reference group was computed and divided

by 100 to obtain the final weight (w) of each criterion (Table 4). The reference group

gave significantly more importance to reliability (w=0.29), affordability (w=0.24) and

energy efficiency (w=0.24) than to material efficiency (w=0.06), user friendliness

(w=0.06), workers’ safety (w=0.06) and climate preservation (w=0.05).

4.2.4. Sustainability scores and ranking

For each alternative, the weighted sum of the seven criteria scores (Table 5) was com-

puted using the weights derived from the budget allocation workshop with the refer-

ence group (Table 4). The weighted sum corresponded to an overall sustainability score

of the alternatives and was the basis for their ranking. For the conditions defined in this

study, the alternative with deep buried gravity sewer and geothermal heat pumps (A4)

was ranked first with a sustainability score of 84/100, mainly because it had the highest

score with regard to two of the three highest weighted criteria (reliability and energy

efficiency). The second alternative in the ranking with a sustainability score of 70/100,

was A5 (low pressure sewer and geothermal heat pumps). A5 had the second highest re-

liability and energy efficiency scores.

Among the shallow co-location alternatives based on low temperature district heating

(A2* and A3*), A2* had the highest overall sustainability score (65/100) and was ranked

third. A2* had the highest score with regard to one of the three highest weighted crite-

ria (affordability). Furthermore, the alternative A2* outranked the traditional alternative

with deep buried gravity sewer and high temperature district heating (A1) by only 2

points. The main differences between these two alternatives were that A2* was more af-

fordable and safer for workers than A1 but less material efficient.

Page 55: Shallow co-location of water, sewer and district heating pipesltu.diva-portal.org/smash/get/diva2:1294643/FULLTEXT01.pdf · rankades som det tredje bästa alternativet medan konventionella

42

Table

4.

Poin

t dis

trib

utions

obta

ined

duri

ng t

he

budget

alloca

tion w

ork

shop (

seve

n s

takeh

old

ers)

, in

term

edia

te c

alcu

lation s

teps

and c

alcu

late

d c

rite

ria

wei

ghts

(sum

equal

to u

nity).

Cri

teri

on

Wate

r su

b-g

roup

Pla

nnin

g

sub-g

roup

Energ

y

su

b-g

roup

H

ousi

ng

su

b-g

roup

Mea

n

of su

b-

gro

up

mea

ns

Sta

ndar

d

dev

iation o

f

sub-g

roup

mea

ns

Fin

al

weig

ht

(w)

p1

p2

p3

Mea

n

p1

Mea

n

p1

Mea

n

p1

p2

Mea

n

C1. E

ner

gy e

ffic

iency

21

16

21

19

21

21

24

24

33

33

33

24

5

0.2

4

C2. C

lim

ate

pre

serv

atio

n

5

11

5

7

5

5

4

4

3

3

3

5

2

0.0

5

C3. M

ater

ial ef

fici

ency

5

11

5

7

5

5

10

10

3

3

3

6

3

0.0

6

C4. A

fford

ability

21

26

21

23

32

32

21

21

22

22

22

24

4

0.2

4

C5. U

ser

frie

ndlines

s 11

5

11

9

3

3

6

6

6

6

6

6

2

0.0

6

C6. W

ork

ers' s

afet

y

5

5

5

5

2

2

4

4

11

11

11

6

3

0.0

6

C7. R

elia

bility

32

26

32

30

32

32

32

32

22

22

22

29

4

0.2

9

Table

5. O

vera

ll w

eighte

d s

core

s an

d r

ankin

g o

f th

e five

alter

nat

ives

det

erm

ined

with t

he

wei

ghte

d s

um

model

. C

rite

ria

score

s an

d c

rite

ria

wei

ghts

are

also p

re-

sente

d. A

bbre

via

tions: G

: gra

vity s

ewer

; LP

S: Low

pre

ssure

sew

er; H

TD

H: hig

h t

emper

ature

dis

tric

t hea

ting; LT

DH

: lo

w t

emper

ature

dis

tric

t hea

ting; G

HP

: geo

-

ther

mal

hea

t pum

p. *

des

ignat

es a

lter

nat

ives

wher

e pip

es for

wat

er s

ervic

es a

nd d

istr

ict

hea

ting a

re c

o-l

oca

ted in a

shal

low

tre

nch

above

the

frost

dep

th.

Score

s

Cri

teri

on

Weig

ht

A1:

G+

HT

DH

A

2*:

G+

LT

DH

A3*:

LPS+

LT

DH

A4:

G+

GH

P

A5:

LPS+

GH

P

C1. E

ner

gy e

ffic

iency

0.2

4

36

37

37

100

87

C2. C

lim

ate

pre

serv

atio

n

0.0

5

14

14

14

100

88

C3. M

ater

ial ef

fici

ency

0.0

6

100

54

54

35

34

C4. A

fford

ability

0.2

4

85

100

96

68

70

C5. U

ser

frie

ndlines

s 0.0

6

100

100

50

50

33

C6. Saf

ety for

work

ers

0.0

6

75

100

100

75

100

C7. R

elia

bility

0.2

9

56

55

18

100

63

Over

all w

eighte

d s

core

63

65

50

84

70

Rankin

g

4

3

5

1

2

Page 56: Shallow co-location of water, sewer and district heating pipesltu.diva-portal.org/smash/get/diva2:1294643/FULLTEXT01.pdf · rankades som det tredje bästa alternativet medan konventionella

43

4.2.5. Sensitivity analysis

The stability of the top-ranked alternative (A4: gravity sewer and geothermal heat

pump) in the face of individual changes in criteria weights was evaluated and appeared

to be relatively high. The most sensitive criteria weight was affordability, which required

a minimum increase of 249% in order to replace A4 by A2* (shallow co-location solu-

tion with gravity sewer and low temperature district heating) as the top-ranked alterna-

tive. This corresponded to a new weight value of 0.52 for the affordability criterion after

re-normalization (re-normalization is to keep the sum of weights equal to unity). The

second most sensitive criteria weight was material efficiency, which required a 525% in-

crease in order to replace A4 by A1 (traditional trench with a gravity sewer and high

temperature district heating). This corresponded to a new weight value of 0.29 for the

material efficiency criterion after re-normalization.

The sensitivity of the sustainability ranking to changes in selected input parameter val-

ues was evaluated and is presented in Table 6. The ranking was found to be rather sta-

ble. Replacing the top-ranked alternative by changing the selected input values was ei-

ther not possible (i.e. for urban density, heat demand, coal fraction and biomass fraction

in energy mixes, district heating and electricity costs) or required major changes. The

coefficient of performance of the geothermal heat pumps was the most sensitive param-

eter and required division by 2.8 (−64%) in order to replace A4 (gravity sewer and geo-

thermal heat pump) by A2* (gravity sewer and LTDH) as the top-ranked alternative.

The second most sensitive parameter was the blockage rate in the gravity sewer system,

requiring multiplication by 4.7 (+370%) in order to replace A4 by A5 (LPS and geo-

thermal heat pump) as the top-ranked alternative. The analysis showed that the shallow

co-location solution with low temperature district heating A2* could top the sustaina-

bility ranking if more than 94% of the heat originated from one central geothermal heat

pump station installed in the neighbourhood.

The sensitivity of the sustainability ranking to the choice of normalization method and

aggregation method was also evaluated. With a min-max (Rowley et al., 2012) normal-

ization scheme instead of the smaller-the-better ratio normalization (Pollesch and Dale,

2016), the sustainability ranking became: A4 (61/100) >A2* (55/100) >A5 (49/100)

>A1 (45/100) > A3* (35/100). If using the weighted geometric mean, which does not

require normalization of the indicator values, the ranking became: A4 (3.2) > A5 (4.0)

> A1 (5.1) > A2* (5.2) > A3* (6.6). This is discussed further in chapter 5.

Page 57: Shallow co-location of water, sewer and district heating pipesltu.diva-portal.org/smash/get/diva2:1294643/FULLTEXT01.pdf · rankades som det tredje bästa alternativet medan konventionella

44

Table 6. Operations required on selected input parameters to change the top-ranked alternative (A4: gravity sewer and geothermal heat pump) and corresponding new sustainability ranking. Abbreviations: f.u: functional unit, DH: district heating, r.u: residential unit, co: connection, NP: not possible, GHP: ge-

othermal heat pump, COP: coefficient of performance LTDH: low temperature district heating. * des-

ignates alternatives where pipes for water services and district heating are co-located in a shallow trench

above the frost depth.

Parameter Unit Original value

Operation to change top

alternative

New rank (new overall weighted score)

A1 A2* A3* A4 A5

Urban den-

sity

f.u / km of pipe 60.1 NP NP

Heat de-mand

kWh/year/r.u 11030 NP NP

Failure rate district heat-

ing

Failure/year/km 0.05 ÷ 20 1 (76)

3 (75)

5 (60)

2 (76)

4 (63)

Failure rate

geothermal heat pump

Failure/year/r.u 0.02 × 20 1

(76)

3

(75)

5

(60)

2

(76)

4

(64)

Blockage rate gravity sewer

Block./co./year 0.03 × 4.7 4 (62)

3 (64)

5 (61)

2 (86)

1 (86)

COP geo-thermal heat

pump

- 4 ÷ 2.8 3 (79)

1 (81)

5 (67)

2 (81)

4 (70)

Coal frac-tion in elec-tricity mix

% 1.2 NP NP

Biomass fraction in DH mix

% 46 NP NP

Geothermal fraction in LTDH mix

% 0 + 94 3 (77)

1 (89)

5 (75)

2 (89)

4 (77)

Linear cost deep trench

€/meter 470 × 28 5 (50)

3

(65)

4

(51)

2

(75)

1 (75)

Lifespan GHP

Year 20 ÷ 11.1 3 (67)

1 (70)

5 (55)

2 (69)

4 (57)

Marginal DH cost

€/kWh 0.023 NP NP

Electricity price

€/kWh 0.08 NP NP

Page 58: Shallow co-location of water, sewer and district heating pipesltu.diva-portal.org/smash/get/diva2:1294643/FULLTEXT01.pdf · rankades som det tredje bästa alternativet medan konventionella

45

5. Discussion

5.1. Comparison with conventional solutions

5.1.1. Freeze protection

Measured and modelled pipe temperatures showed that the shallow co-location solution

could prevent freezing of the drinking water during winter with a safe margin. Indeed, a

minimum water pipe temperature of 3.5○C was estimated for the winter with the cold-

est month/week recorded in Kiruna (1986-87) in the conservative scenario of no

drinking water flow, no snow cover and one heat tracing pipe. This was however condi-

tioned by a constant heat-tracing temperature of 25○C. The heat tracing pipe was most

often in the range 20-30○C during the winter of 2016-2017 (Figure 13) and 25-30

during the winter of 2017-2018 (Paper I). As regards the prevention of sewage freezing,

the measured sewer pipe temperatures during the winter of 2017-2018 were between

3.5 and 7○C at cross section 2 (under a car port, snow-free during winter) when there

was no sewage flow (Paper I). This indicates that the system is able to maintain a positive

temperature in the sewer network under normally cold conditions, as the winter of

2017-2018 was about 1○C colder than the norm for the period 1993-2013 (SHMI,

2019) in Kiruna. On the other hand, the modelling results for the winter of 1986-1987

point out that, under extraordinary cold weather conditions and in the absence of sew-

age flow, negative temperatures can occur inside the sewer pipes during several consecu-

tive days. This would not necessarily induce freezing because sewage is normally dis-

charged by households well above 0○C (Arnell et al., 2017) but still represents a freezing

risk as solids are typically transported intermittently in small diameter sewer pipes

(Littlewood and Butler, 2003). Increasing the heat tracing temperature above 25○C un-

der very cold soil temperature conditions appears to be a viable way of addressing this

problem, as return water in low temperature district heating systems is intended to be

30○C. In the present study, heat tracing temperatures of between 25 and 30

○C were

achieved during the winter of 2017-2018 when regulation strategy B was used. It con-

sisted in operating the heat tracing pump intermittently with the help of a timer whose

on/off cycles were adjusted according to soil and district heating return temperatures

(see 3.1.2).

As regards the freeze protection performance of traditional, deep buried, water and sew-

er pipes, most of the literature available is related to drinking water pipes. In northern

Sweden, freezing of traditionally laid drinking water pipes occurs in the vast majority of

cases in service pipes due to potentially long residence times and reduced installation

depth to reach the basement or ground floor of the building. According to Hanaeus

(1985), freezing of service pipes corresponded to costs of several hundred thousand

Swedish crowns annually for average size municipalities in Northern Sweden (Norr-

Page 59: Shallow co-location of water, sewer and district heating pipesltu.diva-portal.org/smash/get/diva2:1294643/FULLTEXT01.pdf · rankades som det tredje bästa alternativet medan konventionella

46

land) and up to ten times this number during severely cold winters. However, as report-

ed by Janson (1972), freezing can also occur in traditionally laid drinking water mains.

During the winter of 1965-1966, pipe freezes were reported at depths of up to 3.0 m

(Jokkmokk), 3.2 m (Luleå), and 3.4 m (Skellefteå). This is because, depending on the soil

condition, the maximum frost depth under bare ground can be very large and unpracti-

cal to install drinking water mains (VAV, 2001). For that reason, the pipes are sometimes

buried above the maximum frost depth but deep enough to prevent freezing during

normal flow condition and a given stop time (e.g. 20 hours). Freezing may however oc-

cur in these sections in low flow conditions, especially if the drinking water source is

surface water whose inflow temperature can be close to freezing point during winter

(Janson, 1972).

5.1.2. Summer temperatures

In the summer, the main concern with shallow pipe co-location systems is to ensure

that drinking water temperature remains in a safe and comfortable range for the con-

sumer (i.e., <15○C, (Health Canada, 1995)). As shown in Figure 12a, this was not the

case at cross section 1 (section under a lawn where the water pipe is installed 90 cm

deep) during the summer of 2018. The drinking water pipe temperature was then in the

range 15-19○C during a cohesive period of 24 days (Paper I). This was not attributed

solely to high soil temperature at cross section 1, as the latter peaked at 14.9○C during

this period. Another plausible explanation could be that the district heating utilidor was

situated directly on top of the water-sewer utilidor at cross section 1. Soil temperatures

at the level of the pipes were however measured between 15○C and 17.3

○C during 18

days at cross section 2 (19/7-5/8/2018). This corresponded to unfavourable conditions

for cool drinking water as drinking water temperature would exceed 15○C in the ab-

sence of flow or after long transport distance in the network (thermal equilibrium with

the surrounding soil acting as heat sink). The summer of 2018 in Kiruna was warmer

than normal, when taking the period 1991-2013 as the reference (SHMI, 2019). How-

ever, it will correspond to a normal summer by 2070 when we take into account the

effects of climate change (Berglöv et al., 2015). This means that in the future design of

shallow pipe systems, special emphasis should be put on preventing too high drinking

water temperature in the summer case, as the conditions observed during the summer of

2018 are likely to occur regularly and increasingly during their lifetimes. This also ap-

plies for cold climate regions with warmer summers than in Kiruna. In more temperate

areas, the problem of too warm drinking water during summer has been observed for

conventional drinking water networks (Blokker and Pieterse-Quirijns, 2013; Agudelo-

Vera et al., 2014). However, conventional drinking water networks in cold climate re-

gions usually ensure cool drinking water throughout the summer because the soil at the

frost free level remains at relatively low temperature all year round. This means that even

if surface water is used for drinking water, too high raw water temperatures at the intake

Page 60: Shallow co-location of water, sewer and district heating pipesltu.diva-portal.org/smash/get/diva2:1294643/FULLTEXT01.pdf · rankades som det tredje bästa alternativet medan konventionella

47

can potentially be mitigated by the cooling effect of the ground in the distribution net-

work. This possibility is lost when shallow pipe solutions are used. For the sewer net-

work, shallow pipes seem however beneficial in the summer case, as the sewage will not

be cooled down below the surrounding soil temperature (10-17○C in this study), which

is normally warmer than at the frost free depth. As mentioned in the background chap-

ter, warmer sewage temperature is beneficial for wastewater treatment. However, higher

sewage temperature creates also more favourable conditions from the production of hy-

drogen sulphide gas (H2S). According to the model proposed by Nielsen at al. (1998) for

prediction of the H2S production rate in pressure mains, a temperature rise from 10○C

to 20○C increases the H2S production rate by 35%.

5.1.3. Sustainability

The integrated sustainability assessment of five technical alternatives for the provision of

heating and water services to a new residential area suggested that alternative A4 (geo-

thermal heat pumps and deep buried gravity sewer) was more sustainable than the shal-

low co-location alternative A2* (with gravity sewer) and A3* (with low pressure sewer)

which were both based on low temperature district heating (Table 5). These results were

found in the context of the priorities of a group of stakeholders from the town of Gälli-

vare, who attached most importance to reliability, energy efficiency and affordability

(Table 4). Some common priorities may be expected for decision makers in other cold

climate locations. For example, winter conditions can aggravate the consequences of sys-

tem failures, which may in turn increase the perceived importance of reliability in cold

climate regions. Stakeholder preferences can however vary greatly depending on local

contexts and personal experiences.

The sensitivity analysis indicated that the sustainability ranking was relatively stable with

regard to changes of criteria weights (Paper III) but variations of more than one weight

at a time were not investigated. For example, the shallow co-location solution A2* (same

as evaluated in Paper I and II) achieved higher scores than A4 with regard to affordabil-

ity and user friendliness (Figure 16). Decision makers giving more weight to both of

these criteria than in the present study may lead to a rank reversal between A2* and A4.

The sensitivity of the ranking to changes in input parameter values was also analysed in

this study (Table 6) and proved to be quite low. Yet, the influence of input parameter

changes were not evaluated in conjunction with changes in criteria weights.

The input parameters coal fraction in electricity mix and biomass fraction in district heating mix

were two parameters directly impacting on the relative climate preservation scores of

alternatives with heat pumps and those using district heating. The sensitivity analysis

showed that varying these parameters did not change the ranking of A4 as the most sus-

tainable alternative (Table 6). This should be reconsidered if more weight were to be at-

Page 61: Shallow co-location of water, sewer and district heating pipesltu.diva-portal.org/smash/get/diva2:1294643/FULLTEXT01.pdf · rankades som det tredje bästa alternativet medan konventionella

48

tributed to the climate preservation criterion. The reference group in this study attribut-

ed a remarkably low weight of 5% to the climate preservation criterion, given the rec-

ognised urgency of addressing the causes of climate change (IPCC, 2014) and the prom-

inence of climate preservation in recent European policies (European Commision,

2014).

Based on data from the literature (Åkerström, 2004; Haglund Stignor et al., 2012), it was

estimated in this study that alternatives with district heating (A1, A2*, and A3*) would

lead to higher failure rates than alternatives with geothermal heat pumps (A4 and A5).

This made an important contribution to the overall sustainability ranking due to the

high weight given by the reference group to the reliability criteria. There are however

high uncertainties concerning the relative reliability of district heating and geothermal

heat pumps in the present case study. Firstly, national failure statistics were used while

failure rates are normally influenced by site specific parameters such as soil characteristic,

operation & maintenance practices, and quality of installation (Åkerström, 2004;

Haglund Stignor et al., 2012). Therefore, local conditions that can influence the reliabil-

ity of district heating or geothermal heat pumps should also be considered in the deci-

sion making process. For example, the supply of district heat to the residential area stud-

ied in this thesis (Repisvaara) was dependent on a 2.5 km traditional high temperature

pipeline (see section 3.2.3). The latter had a considerable negative impact on the reliabil-

ity of district heating options. This negative impact would be smaller in residential areas

closer to existing district heating grids with alternative routes available in case of pipe

failure (more redundancy). Secondly, PEX pipes for low temperature district heating

(A2* and A3*) is a recent technology for which failures statistics are not available at the

moment. In this study, the same failure rates as for high temperature district heating

pipes in steel were considered. However, PEX pipes may lead to fewer failures since they

are more flexible and corrosion proof than steel pipes. The sensitivity analysis showed

however that a drastic reduction in district heating pipe failure rate (-97%) would be

required to change the top-ranked alternative. Finally, and due to a lack of data on the

topic, the unavailability of the heating system (time in failure condition) was not calcu-

lated. This may affect the results, since fixing a heat pump failure (call of the technician,

diagnostic, ordering spare part, etc..) might take more time than fixing a district heating

pipe servicing several hundred households (work in emergency condition).

As regards the reliability indicator of the sewer system, the number of failures per con-

nection was used (indicator I7b) instead of the failure rate as experienced by the house-

holds. The average number of households affected by one failure is likely to differ be-

tween a gravity system and a low pressure system. Indeed, most failures on LPS systems

occur on the grinder pump (Lindqvist et al., 2000), which affects only one connection

while statistics shows that on the gravity sewer network more than half of blockages oc-

cur in main pipes (VASS, 2017), potentially affecting more than one connection. A

Page 62: Shallow co-location of water, sewer and district heating pipesltu.diva-portal.org/smash/get/diva2:1294643/FULLTEXT01.pdf · rankades som det tredje bästa alternativet medan konventionella

49

deeper analysis of this aspect would be needed to estimate its potential impact on the

sustainability ranking. The validity of the sustainability ranking as found in this thesis,

which gave preference to alternatives with heat pumps, is also conditioned by the num-

ber of households that will choose geothermal heat pumps in the absence of district

heating being available. In Sweden, 62% of heat pumps installed in 2013 were air-to-air

or air-to-water (Swedish Energy Agency, 2015). This number may be different in the

north of the country where colder climate conditions make geothermal heat pumps

more viable but still indicate that a number of household may choose an air heat pump

because it represents a lower investment. This would lower the average COP of the resi-

dential area and, in turn, decrease energy efficiency while affecting affordability. Conse-

quently, the ranking found in the present study should be reconsidered if a large number

of residents install air heat pumps.

The shallow co-location solution A2* was shown to outperform the conventional alter-

natives (both with traditional district heating and geothermal heat pumps) and top the

sustainability ranking if more than 94% of the heat demand (Table 6) was covered by

shallow geothermal energy through a large heat pump situated in the neighbourhood.

This was explained by a large reduction in cumulative exergy demand (CexDe) and

global warming potential (GWP) indicators but also a lower failure rate as it decreased

the reliance on the 2.5 km pipeline connecting the new area to the existing district

heating network of Gällivare. This indicated that, beside the reduction in network heat

losses, the reduction in assembly costs and the reduction in total excavation cost by al-

lowing shallow installation of the water/sewer pipes, the potential of low temperature

district heating to integrate local renewable energy sources (Lund et al., 2010, 2014) had

to also be utilized in order for A2* to outrank alternatives with geothermal heat pumps

(A4 and A5) with regard to sustainability as expressed by the reference group.

5.2. Indicator normalization and aggregation

The weighted sum model used in this study to calculate the sustainability scores requires

normalization of the indicator values (costs, global warming potential, failure rates, etc.)

in order to calculate a sum that is meaningful. As pointed out by several authors, nor-

malization can be done in various ways and can significantly influence the ranking of

alternatives (Rowley et al., 2012; Pollesch and Dale, 2016). Therefore, if the normaliza-

tion method is chosen arbitrarily and/or if its impact on the results is not analysed, addi-

tional subjectivity is brought into the sustainability assessment. In this thesis, ratio nor-

malization (Pollesch and Dale, 2016) was chosen because it conserves proportionality

between the indicator values. The min-max normalization method was not selected be-

cause it requires informing the stakeholders of the spread of values for each indicator

prior to the weighing workshop (DCLG, 2009; Rowley et al., 2012). With this infor-

mation, the stakeholders are expected to lower the weights of criteria with low spread,

Page 63: Shallow co-location of water, sewer and district heating pipesltu.diva-portal.org/smash/get/diva2:1294643/FULLTEXT01.pdf · rankades som det tredje bästa alternativet medan konventionella

50

as the min-max normalization will return score values ranging from 0 to 1 (or any de-

cided maximum), independently of the spread of indicator values. By doing so, the

stakeholders shape the set of weights to the specific studied case, which discards the pos-

sibility of conducting a sensitivity analysis of the results, as the spread of indicator values

will be affected. The use of the min-max normalization was nevertheless tested in this

study to evaluate its impact on the sustainability ranking (section 4.2.5). This was done

with the same weights as those used with the smaller-the-better ratio normalization

method, obtained without informing stakeholders of the spread of criteria values. It did

not change the top-ranked alternative (A4) but affected the ranking significantly, as the

rankings of A2* and A5 were switched. These results highlight the necessity to make an

informed, deliberate choice of normalization method and to adapt the weighing work-

shop accordingly, as this can affect the results significantly. To further investigate the in-

fluence of normalization on the results, the sustainability ranking was also determined

using the weighted geometric mean (section 4.2.5) because this is a normalization-free

method. By this method, only the positions of A1 and A2* were switched in the ranking

and these alternatives had a very low score difference: 0.1 point, in comparison to 0.8 to

3.4 points for the other pairs of alternatives. The low score difference between A1 and

A2* was already found in the original ranking: 2 points in comparison to 5 to 34 points

between the other pairs of alternatives. The similarity between the two rankings suggests

that, the joined use of the weighted sum model and the smaller-the-better ratio normal-

ization scheme, led to overall sustainability scores fairly compliant with the definition of

meaningful synthetizing criterion as proposed by Ebert and Welsch (2004).

Compensatory MCA methods such as the weighted sum model used in this thesis, have

the drawback of allowing a trade-off between criteria, which can contradict the princi-

ple of strong sustainability (Munda, 2005; Rowley et al., 2012; Cinelli et al., 2014). This

is typically illustrated with the example of weak sustainability, where a loss of critical

natural capital (e.g. rain forest) is compensated for by good economic performance

(profits of exploiting the natural capital). Therefore, if a compensatory method is chosen

for practical reasons (in the present study transparency and stakeholder engagement), it is

important to identify the critical resources related to the sustainability criteria, to analyse

if weak-sustainability processes occurred and to estimate to what extent they influenced

the outcome of the assessment. In this project, resources fully or partly related to the

four following criteria can be seen as critical: energy efficiency (non-renewable energy),

climate preservation (a liveable climate), material efficiency (rare elements) and workers’

safety (human life). The two alternatives at the top of the ranking (A4 and A5) were the

most energy efficient (C1) / decarbonised (C2) as well as the most expensive (C4).

Therefore, weak sustainability processes seem to have played only a minor role in the

assessment. However, the poor performances of A4 and A5 with regard to material effi-

ciency (score of 35/100 and 34/100) were largely compensated for by high perfor-

Page 64: Shallow co-location of water, sewer and district heating pipesltu.diva-portal.org/smash/get/diva2:1294643/FULLTEXT01.pdf · rankades som det tredje bästa alternativet medan konventionella

51

mances with regard to other criteria, but this was mainly due to the low weight given

by the stakeholders to that criterion.

5.3. Suggestions of improvement of the technical solution

To ensure sewer pipe temperatures above 0○C in the event of very cold soil tempera-

tures (below -10○C) and avoid drinking water temperature above 15

○C when soil tem-

peratures are just below 0○C, it appears necessary to modulate the heat tracing tempera-

ture throughout the winter instead of using a constant value of 25○C (Figure 15). In the

present study, such modulation was achieved during the winter of 2017-2018 by operat-

ing the heat tracing pump with on/off cycles adjusted according to soil temperature and

district heating return water temperature. In milder locations where a narrower range of

negative soil temperatures is expected, a constant heat tracing temperature may be suffi-

cient to achieve the desired drinking water and sewer temperature levels (0-15○C and

>0○C). For the summer case, ensuring drinking water temperatures below 15

○C should

be addressed during design / construction by: (a) evaluating summer soil temperatures at

the depth of the utilidor; (b) if soil temperature will exceed 15○C, providing sufficient

insulation thickness to prevent warming of the cold water above that temperature dur-

ing its residence time in the shallow utilidor; (c) avoid stacking the water-sewer and dis-

trict heating utilidors.

Good control of the winter heat tracing system requires limiting the temperature drops

in the single-pipe heat tracing network (from the district heating house station where

the heat tracing pump is located to each house). This should be verified before using the

shallow co-location solution on systems larger than the one tested in Kiruna (9 single

family homes). However, the hydraulics of the heat tracing system can be difficult to

model during the design stage as they are fully coupled with the district heating grid.

For example, the flow in each branch of the heat tracing system depends on the pressure

level in the return district heating pipe of each house, itself dependent on the district

heating operation, demand patterns, etc. It may be more convenient for design and op-

eration to use a dual-pipe heat tracing system, independent from the low temperature

district heating system. This would require an extra heat exchanger in the district heat-

ing house station and would double the heat tracing pipe length, thus also increasing

costs. Another aspect to consider is whether or not the entire drinking water/sewer

networks of the area considered need to be heat traced. Upstream pipe sections with

sufficient daily flow even during holiday periods may be protected from freezing solely

with the insulation provided by the EPS utilidor (Janson, 1972; Gunderson, 1978;

Öhman, 1982, 1984).

Page 65: Shallow co-location of water, sewer and district heating pipesltu.diva-portal.org/smash/get/diva2:1294643/FULLTEXT01.pdf · rankades som det tredje bästa alternativet medan konventionella

52

Drinking water and sewer pipes were installed at the same level in the co-location solu-

tion evaluated in this thesis. However, in a conventional trench, the drinking water pipe

is normally installed above the sewer pipe (Svensk Byggtjänst, 2017) to mitigate cross

contamination risks. This requirement should also be considered when developing fur-

ther the design of the shallow co-location solution studied in this thesis.

Page 66: Shallow co-location of water, sewer and district heating pipesltu.diva-portal.org/smash/get/diva2:1294643/FULLTEXT01.pdf · rankades som det tredje bästa alternativet medan konventionella

53

6. Conclusions

In this work, a technical solution for installing drinking water, sewer and low tempera-

ture district heating pipes in a single shallow trench in seasonally frozen ground was

evaluated. The following conclusions were drawn concerning the co-location solution:

Drinking water and sewer pipes remained at non-freezing and comfortable (below

15○C for drinking water) temperatures during most of the study period at the two

trench sections studied at the pilot site in Kiruna. The exception to this was the

summer of 2018 when daily drinking water pipe temperatures were in the range

15-19○C during 24 days at cross section 1 situated under a lawn.

The finite volume thermal model of cross section 2, calibrated on the basis of one

year of measurements, could predict drinking water (R2=0.70, RMSE=1.84○C) and

sewer pipe (R2=0.82, RMSE=1.69○C) temperatures with fairly high accuracy dur-

ing validation period 1 (case without drinking water/sewage flow). The same model

indicated that the drinking water temperature would have remained positive during

the record cold winter of 1986-1987 but that sewer temperature would have

dropped below 0○C during 14 days and reached a minimum of -4.5

○C in the ab-

sence of sewage flow and for a constant heat tracing temperature of 25○C.

In the sustainability assessment for the residential area of Repisvaara, the alternative

with geothermal heat pumps and traditional gravity sewer (A4) had a cumulative

exergy demand 63% lower than the shallow co-location solution with low tempera-

ture district heating and gravity sewer (A2*). Besides, the total cost of A2* on a life

cycle perspective was found to be 32% lower than for A4 and 15% lower than for

the traditional alternative with deep gravity sewer and high temperature district

heating (A1). Alternatives with geothermal heat pumps (e.g. A4) were estimated to

correspond to a 90% lower failure rate of the heating system than the shallow co-

location solutions with low temperature district heating (e.g. A2*).

After aggregating the indicator values using a weighted sum approach with weights

obtained from a group of local stakeholders, the shallow co-location solution (A2*)

was ranked third with a sustainability score of 65/100 and the alternative, featuring

deep gravity sewer and individual geothermal heat pumps (A4), topped the ranking

with a score of 87/100. The stakeholders gave most weight to the reliability (29%),

energy efficiency (24%) and affordability (24%) criteria.

The stability of the top-ranked alternative (A4) in the face of individual changes in

criteria weights and a number of input parameters (e.g. urban density, residential

heat demand, failure rates) was relatively high. The sensitivity analysis also showed

Page 67: Shallow co-location of water, sewer and district heating pipesltu.diva-portal.org/smash/get/diva2:1294643/FULLTEXT01.pdf · rankades som det tredje bästa alternativet medan konventionella

54

that the shallow co-location solution would top the sustainability ranking if more

weight was given to affordability (52% instead of 24%) or if more than 94% of the

district heat was produced with a central geothermal heat pump station installed in

the neighbourhood.

The results suggest that the shallow co-location solution may be a viable heat and water

services provision alternative in regions with a climate similar to Northern Sweden, giv-

en that (a) potential risks of undesirably warm drinking water during summer are ad-

dressed in the design stage, (b) heat tracing temperature can be kept close to 25○C in the

entire system during winter and increased in case of very cold soil conditions (<-10○C),

and (c) the district heating system is equally or more energy efficient and decarbonised

than the average heating system of the area if residents would choose their own individ-

ual solution.

Page 68: Shallow co-location of water, sewer and district heating pipesltu.diva-portal.org/smash/get/diva2:1294643/FULLTEXT01.pdf · rankades som det tredje bästa alternativet medan konventionella

55

References

Abdel-Aal, M., Smits, R., Mohamed, M., De Gussem, K., Schellart, A., Tait, S., 2014. Modelling the viability of heat recovery from combined sewers. Water Sci. Technol. 70, 297 LP-306.

Agudelo-Vera, C., Blokker, M., Pieterse-Quirijns, I., 2014. Early Warning Systems to Predict Temperature in the Drinking Water Distribution Network. Procedia Eng. 70, 23–30. https://doi.org/10.1016/j.proeng.2014.02.004

Åkerström, Å., 2004. Re-investment model for existing district heating networks (Reinvesteringsmodell för befintligt fjärrvärmenät, in Swedish). Thesis project, Technical Faculty of Lund University (LTH).

Akhtar, S., Reza, B., Hewage, K., Shahriar, A., Zargar, A., Sadiq, R., 2015. Life cycle sustainability assessment (LCSA) for selection of sewer pipe materials. Clean Technol. Environ. Policy 17, 973–992. https://doi.org/10.1007/s10098-014-0849-x

Alanne, K., Salo, A., Saari, A., Gustafsson, S.-I., 2007. Multi-criteria evaluation of residential energy supply systems. Energy Build. 39, 1218–1226. https://doi.org/10.1016/j.enbuild.2007.01.009

Alegre, H., Cabrera Rochera, E., Hein, A., Brattebø, H., 2014. Framework for Sustainability Assessment of UWCS and development of a self-assessment tool.

Andersland, O.B., Ladanyi, B., 1994. An introduction to frozen ground engineering. Chapman & Hall, New York.

Ariaratnam, S.T., Piratla, K., Cohen, A., Olson, M., 2013. Quantification of Sustainability Index for Underground Utility Infrastructure Projects. J. Constr. Eng. Manag. 139, A4013002. https://doi.org/10.1061/(asce)co.1943-7862.0000763

Arnell, M., Lundin, E., Jeppsson, U., 2017. Sustainability Analysis for Wastewater Heat Recovery – Literature Review. https://doi.org/10.13140/rg.2.2.27365.91364

ASCE, 2017. Report Card for America’s Infrastrure, American Society of Civil Engineers. www.infrastructurereportcard.org (accessed 1.31.19).

Ashley, R.M., Blackwood, D., Butler, D., Jowitt, P., 2004. Sustainable Water Services: A Procedural Guide. Sustainable Water Industry Asset Resources Decisions Project. London: IWA Publishing.

ASRTE, 1999. Swiss Standard SN 670 010b, Characteristic Coefficients of soils. Association of Swiss Road and Traffic Engineers.

Beck, H.E., Zimmermann, N.E., McVicar, T.R., Vergopolan, N., Berg, A., Wood, E.F., 2018. Present and future Köppen-Geiger climate classification maps at 1-km resolution. Sci. Data 5, 180214.

Benayoun, R., Roy, B., Sussman, N., 1966. Manual de Reference du Programme Electre. SEMA, Paris, France.

Berglöv, G., Asp, M., Clausen, S.B.-, Björck, E., Mårtensson, A.J., Nylén, L., Ohlsson, A., Persson, H., Sjökvist, E., 2015. Future climate in Norrbotten county (Framtidsklimat i Norrbottens län, in Swedish). Klimatologi 16.

Page 69: Shallow co-location of water, sewer and district heating pipesltu.diva-portal.org/smash/get/diva2:1294643/FULLTEXT01.pdf · rankades som det tredje bästa alternativet medan konventionella

56

Bishop, M.P., Bush, A.B.G., Furfaro, R., Gillespie, A.R., Hall, D.K., Haritashya, U.K., Shroder, J.F., 2014. Theoretical Foundations of Remote Sensing for Glacier Assessment and Mapping, in: Kargel, J.S., Leonard, G.J., Bishop, M.P., Kääb, A., Raup, B.H. (Eds.), Global Land Ice Measurements from Space. Springer Berlin Heidelberg, Berlin, Heidelberg, pp. 23–52. https://doi.org/10.1007/978-3-540-79818-7_2

Blokker, E.J.M., Pieterse-Quirijns, E.J., 2013. Modeling temperature in the drinking water distribution system. J. Am. Water Work. Assoc. 105, E19–E28. https://doi.org/10.5942/jawwa.2013.105.0011

Bösch, M.E., Hellweg, S., Huijbregts, M.A.J., Frischknecht, R., 2007. Applying cumulative exergy demand (CExD) indicators to the ecoinvent database. Int. J. Life Cycle Assess. 12, 181–190. https://doi.org/10.1065/lca2006.11.282

Boverket., 2016. Boverket’s Building regulations - mandatory provisions and general recommendations, BBR. http://www.boverket.se/globalassets/publikationer/dokument/2016/boverkets-building-regulations--mandatory-provisions-and-general-recommendations-bbr-23.pdf (accessed 2.5.18).

Brans, J.P., Vincke, P., 1985. Note—A Preference Ranking Organisation Method. Manage. Sci. 31, 647–656. https://doi.org/10.1287/mnsc.31.6.647

Brattebø, H., Alegre, H., Cabrera, E., Marques, R., Hein, A., Cruz, C., 2013. A master framework for UWCS sustainability. Trust. http//www. Trust. net/downloads.

Bridgman, P.., 1922. Dimensional analysis. Yale University Pres, New Haven, CT.

Cinelli, M., Coles, S.R., Kirwan, K., 2014. Analysis of the potentials of multi criteria decision analysis methods to conduct sustainability assessment. Ecol. Indic. 46, 138–148. https://doi.org/10.1016/j.ecolind.2014.06.011

Connolly, D., Lund, H., Mathiesen, B.V., Werner, S., Möller, B., Persson, U., Boermans, T., Trier, D., Østergaard, P.A., Nielsen, S., 2014. Heat Roadmap Europe: Combining district heating with heat savings to decarbonise the EU energy system. Energy Policy 65, 475–489. https://doi.org/10.1016/j.enpol.2013.10.035

Coutermarsh, B., Carbee, D., 1998. Frost-Shielding Methodology and Demonstration for Shallow Burial of Water and Sewer Utility Lines. Cold Reg. Res. Eng. Lab. Rep. 98-4.

DCLG, 2009. Multi-criteria analysis: a manual. Department for Communities and Local Government, London.

de la Fuente, A., Pons, O., Josa, A., Aguado, A., 2016. Multi-Criteria Decision Making in the sustainability assessment of sewerage pipe systems. J. Clean. Prod. 112, 4762–4770. https://doi.org/10.1016/j.jclepro.2015.07.002

Dennison, F.J., Azapagic, A., Clift, R., Colbourne, J.S., 1999. Life cycle assessment: Comparing strategic options for the mains infrastructure — Part I. Water Sci. Technol. 39, 315–319. https://doi.org/10.1016/S0273-1223(99)80002-X

Diaz-Balteiro, L., González-Pachón, J., Romero, C., 2017. Measuring systems sustainability with multi-criteria methods: A critical review. Eur. J. Oper. Res. 258, 607–616. https://doi.org/10.1016/j.ejor.2016.08.075

Page 70: Shallow co-location of water, sewer and district heating pipesltu.diva-portal.org/smash/get/diva2:1294643/FULLTEXT01.pdf · rankades som det tredje bästa alternativet medan konventionella

57

Dürrenmatt, D.J., Wanner, O., 2014. A mathematical model to predict the effect of heat recovery on the wastewater temperature in sewers. Water Res. 48, 548–58. https://doi.org/10.1016/j.watres.2013.10.017

Ebert, U., Welsch, H., 2004. Meaningful environmental indices: a social choice approach. J. Environ. Econ. Manage. 47, 270–283. https://doi.org/10.1016/j.jeem.2003.09.001

European Commision, E., 2014. 2030 framework for climate and energy - Outcome of the October 2014 European Council. https://ec.europa.eu/clima/sites/clima/files/strategies/2030/docs/2030_euco_conclusions_en.pdf (accessed 4.30.18).

Farouki, O.T., 1981. Thermal properties of soils. Cold Regions Research and Engineering Laboratory, Hanover, NH.

Fishburn, P.., 1967. Additive utilities with incomplete product set: Applications to priorities and assignments. Operations Research Society of America (ORSA), Baltimore, MD.

Foxon, T.J., Mcilkenny, G., Gilmour, D., Oltean-Dumbrava, C., Souter, N., Ashley, R., Butler, D., Pearson, P., Jowitt, P., Moir, J., 2002. Sustainability Criteria for Decision Support in the UK Water Industry AU -. J. Environ. Plan. Manag. 45, 285–301. https://doi.org/10.1080/09640560220116341

Frischknecht, R., Wyss, F., Büsser Knöpfel, S., Lützkendorf, T., Balouktsi, M., 2015. Cumulative energy demand in LCA: the energy harvested approach. Int. J. Life Cycle Assess. 20, 957–969. https://doi.org/10.1007/s11367-015-0897-4

Galloway, G.E., 2011. If Stationarity is Dead, What Do We Do Now?1. JAWRA J. Am. Water Resour. Assoc. 47, 563–570. https://doi.org/10.1111/j.1752-1688.2011.00550.x

Geo-slope, 2010. Thermal Modeling with TEMP/W 2007.

GEODH, 2014. Developing geothermal district heating in Europe. European Geothermal Energy Council, Brussels, Belgium.

Ghafghazi, S., Sowlati, T., Sokhansanj, S., Melin, S., 2010. A multicriteria approach to evaluate district heating system options. Appl. Energy 87, 1134–1140. https://doi.org/10.1016/j.apenergy.2009.06.021

Grujić, M., Ivezić, D., Živković, M., 2014. Application of multi-criteria decision-making model for choice of the optimal solution for meeting heat demand in the centralized supply system in Belgrade. Energy 67, 341–350. https://doi.org/10.1016/j.energy.2014.02.017

Gunderson, P., 1978. Frost Protection of Buried Water and Sewage Pipes (draft translation 666). Cold Region Research and Engineering Laboratory, Hanover, NH, Cold Region Engineering Laboratory report: draft translation 666.

Haglund Stignor, C., Larsson, K., Jensen, S., Larsson, J., Berg, J., Lidbom, P., Rolfsman, L., 2012. Improved reliability of heat pumps in single family homes (Förbättrad driftsäkerhet hos villavärmepumpar, in Swedish). Report of the Technical Research Institute of Sweden SP-RAPP 2012:41.

Hanaeus, J., 1985. Freezing problems in drinking water service connections (Frysproblem i servisledingar för dricksvatten, in Swedish) - Research report 23, Luleå University of Technology.

Page 71: Shallow co-location of water, sewer and district heating pipesltu.diva-portal.org/smash/get/diva2:1294643/FULLTEXT01.pdf · rankades som det tredje bästa alternativet medan konventionella

58

Health Canada, 1995. Guidelines for Canadian Drinking Water Quality: Guideline Technical Document – Temperature.

Hellström, D., Jeppsson, U., Kärrman, E., 2000. A framework for systems analysis of sustainable urban water management. Environ. Impact Assess. Rev. 20, 311–321. https://doi.org/10.1016/S0195-9255(00)00043-3

Henze, M., Harremoes, P., Jansen, J.C., Arvin, E., 2001. Wastewater Treatment: Biological and Chemical Processes, Environmental Science and Engineering. Springer Berlin Heidelberg.

Hojjati, A., Jefferson, I., Metje, N., Rogers, C.D.F., 2018. Sustainability assessment for urban underground utility infrastructure projects. Proc. Inst. Civ. Eng. - Eng. Sustain. 171, 68–80. https://doi.org/10.1680/jensu.16.00050

Hunt, D.V.L., Nash, D., Rogers, C.D.F., 2014. Sustainable utility placement via Multi-Utility Tunnels. Tunn. Undergr. Sp. Technol. 39, 15–26. https://doi.org/10.1016/j.tust.2012.02.001

Hwang, C.-L., Yoon, K., 1981. Multiple Attribute Decision Making, Lecture Notes in Economics and Mathematical Systems. Springer Berlin Heidelberg, Berlin, Heidelberg. https://doi.org/10.1007/978-3-642-48318-9

IPCC, 2014. Climate Change 2014 Synthesis Report - Intergovernmental Panel on Climate Change, Climate Change 2014: Synthesis Report. Contribution of Working Groups I, II and III to the Fifth Assessment Report of the Intergovernmental Panel on Climate Change. https://doi.org/10.1017/cbo9781107415324

IPCC, 2007. Climate Change 2007, The physical Basis - Contribution of Working Group I to the Fourth Assessment Report of the Intergovernmental Panel on Climate Change. Cambridge University Press, Cambridge, United Kindgom and New York, NY, USA.

ISO, 2006. Standard 14040: Environmental management -- Life cycle assessment -- Principles and framework.

Janson, L.E., 1972. Ground Frost Penetration in Sweden, Technical translation (National Research Council of Canada); no. TT-1532. National Research Council Canada. https://doi.org/10.4224/20359073

Johansen, O., 1975. Thermal conductivity of soils. CRREL Draft Transl. 637.

Kabir, G., Sadiq, R., Tesfamariam, S., 2014. A review of multi-criteria decision-making methods for infrastructure management. Struct. Infrastruct. Eng. 10, 1176–1210. https://doi.org/10.1080/15732479.2013.795978

Kärrman, E., Pettersson, F., Erlandsson, Å., 2012. Costs for water and wastewater systems in transition areas – a guide book (Kostnader för VA i omvandlingsområden – en handledning, in Swedish). Research report 2012-09 of the Swedish Water and Wastewater Association (SVU rapport).

Kennedy, F.E., Phetteplace, G.E., Humiston, N., Prabhakar, V., 1988. Thermal performance of a shallow utilidor, in: International Conference on Permafrost, 5th, Trondheim, Norway, Aug. 2-5, 1988. pp. 1262–1267.

Kontu, K., Rinne, S., Olkkonen, V., Lahdelma, R., Salminen, P., 2015. Multicriteria evaluation of heating choices for a new sustainable residential area. Energy Build. 93, 169–179. https://doi.org/10.1016/j.enbuild.2015.02.003

Page 72: Shallow co-location of water, sewer and district heating pipesltu.diva-portal.org/smash/get/diva2:1294643/FULLTEXT01.pdf · rankades som det tredje bästa alternativet medan konventionella

59

Koo, D.-H., Ariaratnam, S.T., 2008. Application of a Sustainability Model for Assessing Water Main Replacement Options. J. Constr. Eng. Manag. 134, 563–574. https://doi.org/10.1061/(ASCE)0733-9364(2008)134:8(563)

Köppen, W., 1884. Die Wärmezonen der Erde, nach der Dauer der heissen, gemässigten und kalten Zeit und nach der Wirkung der Wärme auf die organische Welt betrachtet. Meteorol. Zeitschrift 1.

Lai, E., Lundie, S., Ashbolt, N.J., 2008. Review of multi-criteria decision aid for integrated sustainability assessment of urban water systems. Urban Water J. 5, 315–327. https://doi.org/10.1080/15730620802041038

Leitch, A.F., Heinke, G.W., 1970. Comparison of Utilidors in Inuvik, NWT. Department of Civil Engineering, University of Toronto, Toronto, Ontario.

Li, X., Gu, D.-M., Qi, J.-Y., M, U., Zhao, H.-B., 2003. Modeling of residual chlorine in water distribution system. J. Environ. Sci. (China) 15, 136–44.

Lindqvist, B.G., Lönnbring, J., Persson, G., Svensson, H., 2000. Low Pressure Sewerage Systems with lesser dimater piping (Tryckavloppssystem av rör med klena dimensioner, in Swedish). Swedish Water and Wastewater Association, Bromma, Sweden.

Littlewood, K., Butler, D., 2003. Movement mechanisms of gross solids in intermittent flow, Water science and technology : a journal of the International Association on Water Pollution Research. https://doi.org/10.2166/wst.2003.0217

Lund, H., Möller, B., Mathiesen, B.V., Dyrelund, A., 2010. The role of district heating in future renewable energy systems. Energy 35, 1381–1390. https://doi.org/10.1016/j.energy.2009.11.023

Lund, H., Werner, S., Wiltshire, R., Svendsen, S., Thorsen, J.E., Hvelplund, F., Mathiesen, B.V., 2014. 4th Generation District Heating (4GDH). Energy 68, 1–11. https://doi.org/10.1016/j.energy.2014.02.089.

Lundie, S., Ashbolt, N., Lai, E., Kärrman, E., Blaikie, J., Anderson, J., 2008. Part A: Methodology for evaluating the overall sustainability of urban water systems. WSAA occasional paper n. 17.

Malm, A., Svensson, G., Bäckman, H., Morrison, G.M., 2013. Prediction of water and wastewater networks rehabilitation based current age and material distribution. Water Sci. Technol. Water Supply 13, 227–237. https://doi.org/10.2166/ws.2013.011

Malmqvist, P.-A., Heinicke, G., Korrman, E., Stenstrom, T.A., Svensson, G., 2006. Strategic planning of sustainable urban water management. IWA publishing.

Martini, W.R., Churchill, S.W., 1960. Natural Convection Inside a Horizontal Cylinder. A.I.Ch.E. J. 6, 251–257.

Mcfadden, T., 1990. The kilpisjarvi project: case study of cold-regions research in finland. J. Cold Reg. Eng. 4, 69–84.

Mebratu, D., 1998. Sustainability and sustainable development: historical and conceptual review. Environ. Impact Assess. Rev. 18, 493–520.

Meggers, F., Leibundgut, H., 2011. The potential of wastewater heat and exergy: Decentralized high-temperature recovery with a heat pump. Energy Build. 43, 879–886. https://doi.org/10.1016/j.enbuild.2010.12.008

Page 73: Shallow co-location of water, sewer and district heating pipesltu.diva-portal.org/smash/get/diva2:1294643/FULLTEXT01.pdf · rankades som det tredje bästa alternativet medan konventionella

60

Motevallian, S., Tabesh, M., 2011. A Framework for Sustainability Assessment of Urban Water Systems Using a Participatory Approach. https://doi.org/10.13140/2.1.2006.8803

Mroz, T.M., 2008. Planning of community heating systems modernization and development. Appl. Therm. Eng. 28, 1844–1852.

Munda, G., 2005. Multiple Criteria Decision Analysis and Sustainable Development, in: Multiple Criteria Decision Analysis: State of the Art Surveys. Springer-Verlag, New York, pp. 953–986. https://doi.org/10.1007/0-387-23081-5_23

Nacka Municipality., 2012. Comparative study between LPS and gravity sewer system (Jämförelsestudie LTA-Självfallssystem, in Swedish). Nacka, Sweden.

Nardo, M., Saisana, M., Saltelli, A., Tarantola, S., 2005. Tools for Composite Indicators Building, Report of the Join Research Centre - European Commission.

Nash, J.E., Sutcliffe, J. V, 1970. River flow forecasting through conceptual models part I — A discussion of principles. J. Hydrol. 10, 282–290. https://doi.org/https://doi.org/10.1016/0022-1694(70)90255-6

Nielsen, P.H., Raunkjær, K., Hvitved-Jacobsen, T., 1998. Sulfide production and wastewater quality in pressure mains. Water Sci. Technol. 37, 97–104. https://doi.org/10.1016/S0273-1223(97)00758-0

Öhman, I., 1984. Heat gains from sewer pipes (Värmeavgivning från spillvattenledningar, in Swedish) - Research report 20, Luleå University of Technology.

Öhman, I., 1982. Shallow insulated water and sewer pipes in cold climate (Grunda isolerade VA-ledingar i kallt klimat, in Swedish) - Research report 8, Luleå University of Technology.

Olsson, G., 2012. Water and Energy Nexus, in: Meyers, R.A. (Ed.), Encyclopedia of Sustainability Science and Technology. Springer New York, New York, NY, pp. 11932–11946. https://doi.org/10.1007/978-1-4419-0851-3_331

Pangborn, R.M., Bertolero, L.L., 1972. Influence of Temperature on Taste Intensity and Degree of Liking of Drinking Water. J. Am. Water Works Assoc. 64, 511–515.

Persson, C., Fröling, M., Svanström, M., 2006. Life Cycle Assessment of the District Heat Distribution System. Part 3: Use Phase and Overall Discussion (10 pp). Int. J. Life Cycle Assess. 11, 437–446. https://doi.org/10.1065/lca2005.08.225

Perzon, M., Johansson, K., Fröling, M., 2007. Life cycle assessment of district heat distribution in suburban areas using PEX pipes insulated with expanded polystyrene. Int. J. Life Cycle Assess. 12, 317–327. https://doi.org/10.1065/lca2006.08.264

Petit-Boix, A., Sanjuan-Delmás, D., Gasol, C.M., Villalba, G., Suárez-Ojeda, M.E., Gabarrell, X., Josa, A., Rieradevall, J., 2014. Environmental Assessment of Sewer Construction in Small to Medium Sized Cities Using Life Cycle Assessment. Water Resour. Manag. 28, 979–997. https://doi.org/10.1007/s11269-014-0528-z

Piratla, K.R., Ariaratnam, S.T., Cohen, A., 2011. Estimation of CO 2 emissions from the life cycle of a potable water pipeline project. J. Manag. Eng. 28, 22–30.

Pollesch, N.L., Dale, V.H., 2016. Normalization in sustainability assessment: Methods and implications. Ecol. Econ. 130, 195–208. https://doi.org/10.1016/j.ecolecon.2016.06.018

Page 74: Shallow co-location of water, sewer and district heating pipesltu.diva-portal.org/smash/get/diva2:1294643/FULLTEXT01.pdf · rankades som det tredje bästa alternativet medan konventionella

61

Raymond, D., Scothorn, P., Zhao, J.Q., Rajani, B.B., Daigle, L., 1999. A Practical measure to prevent frozen water service lines - the Region of Ottawa Carleton’s experience, in: CSCE 1999 Annual Conference - 14th Canadian Hydrotechnical Conference. pp. 421–430.

Reed, S.C., 1977. Field performance of a subarctic utilidor, in: Proceedings, Utilities Delivery in Arctic Regions. Environmental Protection Service Rep. No. EPS 3-WP-77-1, Ottawa, Ontario, pp. 391–438.

Risberg, D., Vesterlund, M., Westerlund, L., Dahl, J., 2015. CFD simulation and evaluation of different heating systems installed in low energy building located in sub-arctic climate. Build. Environ. 89, 160–169. https://doi.org/10.1016/j.buildenv.2015.02.024

Rogness, D.R., Ryan, W., 1977. Vacuum sewage collection in the Arctic, Noorvik, Alaska: A case study., in: Proceedings, Utilities Delivery in Arctic Regions. Environmental Protection Service Rep. No. EPS 3-WP-77-1, Ottawa, Ontario,. pp. 505–552.

Rowley, H. V., Peters, G.M., Lundie, S., Moore, S.J., 2012. Aggregating sustainability indicators: Beyond the weighted sum. J. Environ. Manage. 111, 24–33. https://doi.org/10.1016/j.jenvman.2012.05.004

Roy, B., 2005. Paradigms and Challenges, in: Multiple Criteria Decision Analysis: State of the Art Surveys. Springer-Verlag, New York, pp. 3–24. https://doi.org/10.1007/0-387-23081-5_1

Saaty, T.L., 1980. The analytic hierarchy process. McGraw Hill, New York, NY.

Sanjuan-Delmás, D., Petit-Boix, A., Gasol, C.M., Villalba, G., Suárez-Ojeda, M.E., Gabarrell, X., Josa, A., Rieradevall, J., 2014. Environmental assessment of different pipelines for drinking water transport and distribution network in small to medium cities: a case from Betanzos, Spain. J. Clean. Prod. 66, 588–598. https://doi.org/10.1016/j.jclepro.2013.10.055

Schubert, D., Crum, J., Jones, G., Ronimus, A., 2013. Water Distribution Design and Construction in Alaska-Historic Perspectives and Current Practice, in: ISCORD 2013. American Society of Civil Engineers, pp. 840–851.

SHMI, 2019. Månads-, årstids- och årskartor - Swedish Meteorological and Hydrological Institute (SMHI). https://www.smhi.se/klimatdata/meteorologi/kartor/monYrTable.php?myn=1&par=tmpSeasAvv (accessed 3.24.19).

SMHI, 2019. Climate data of Sweden - Swedish Meteorological and Hydrological Institute (SMHI). http://www.smhi.se/klimatdata (accessed 3.29.19).

SMHI, 2018. Meteorological observations (Meteorologiska observationer, in Swedish). Swedish Meteorogical and Hydrological Institute (SMHI). https://opendata-download-metobs.smhi.se/explore/ (accessed 9.25.18).

Smith, D., 1996. Cold Regions Utilities Monograph, Third Edit. ed. American Society of Civil Engineers, New York, NY.

Svensk Byggtjänst, 2017. General Material and Work Description for Construction Works (Allmän Material- och Arbetsbeskrivning för anläggningsarbete, in Swedish), Svensk Byggtjänst, Stockholm, Sweden.

Page 75: Shallow co-location of water, sewer and district heating pipesltu.diva-portal.org/smash/get/diva2:1294643/FULLTEXT01.pdf · rankades som det tredje bästa alternativet medan konventionella

62

SWEA., 2018. Work accidents and sickness statistics (Arbetsskadestatistik, in Swedish). Swedish Work Environment Authority (Arbetsmiljöverket). http://webbstat.av.se/QvAJAXZfc/opendoc.htm?document=accesspoint%5Carbetsskadestatistik.qvw&host=QVS%40vmextapp02-hk&anonymous=true (accessed 2.27.18).

Swedish Energy Agency, 2015. Heatpumps’ role on the heating market (Värmepumparnas roll på uppvärmningsmarknaden, in Swedish). https://energimyndigheten.a-w2m.se/FolderContents.mvc/Download?ResourceId=3044 (accessed 2.5.18).

SWWA, 2016. P110 part 1 and 2, Transport of stormwater and wastewater (P110 del 1 och 2, Avledning av dag-, drän- och spillvatten, in Swedish). Swedish Water and Wastewater Association, Bromma, Sweden.

Tanskanen, V., 2018. Sustainability of Sewer Systems for Source Separated Blackwater. Chalmers University of Technology, Gothenburg, Sweden.

Tekniska Verken, 2017. Tekniska verken i Linköping AB - Utilidor in Vallastaden (Kulvertsystem i Vallastaden, in Swedish). https://www.tekniskaverken.se/om-oss/innovation/innovativa-projekt/kulvertsystem-i-vallastaden/?login=reset&private=true (accessed 3.12.19).

Triantaphyllou, E., 2000. Multi-Criteria Decision Making Methods: A Comparative Study. Springer, Dordrecht.

Vahidi, E., Jin, E., Das, M., Singh, M., Zhao, F., 2016. Environmental life cycle analysis of pipe materials for sewer systems. Sustain. Cities Soc. 27, 167–174. https://doi.org/10.1016/j.scs.2016.06.028

van Oers, L., de Koning, A., Guinée, J.B., Huppes, G., 2002. Abiotic resource depletion in LCA. Ministry of Transport, Public Works and Water Management, Delft, The Netherlands.

VASS, 2017. Swedish Water and Wastewater Association Statistic System (Svenskt Vattens Statistik System, in Swedish) http://www.vass-statistik.se/ (accessed 12.15.17).

VAV, 2001. Installation depth for water and sewer pipes in soil with regard to ground frost (Läggningsdjup för VA-ledningar I jord med hänsyn till tjäle, in Swedish). Report P86 of the Swedish Water and Wastewater Association.

VDI, 1997. Cumulative energy demand terms, definitions, methods of calculation, VDI-Richtlinien 4600, Verein Deutscher Ingenieure. Beuth, Düsseldorf, Germany.

WCED, 1987. Our Common Future. United Nations World Commission on Environment and Development (Chaired by Gro Brundtland). London: Oxford University Press.

Werner, S., 2017. District heating and cooling in Sweden. Energy 126, 419–429. https://doi.org/10.1016/j.energy.2017.03.052

World Health Organisation, 2008. Guidelines for drinking-water quality, 3rd edition: Volume 1 - Recommendations.

Page 76: Shallow co-location of water, sewer and district heating pipesltu.diva-portal.org/smash/get/diva2:1294643/FULLTEXT01.pdf · rankades som det tredje bästa alternativet medan konventionella

Shallow co-location of water, sewer and district heating pipes:

Applicability in cold climate regions

Youen Pericault

Urban Water Engineering

Department of Civil, Environmental and Natural Resources EngineeringDivision of Architecture and Water