Upload
others
View
52
Download
1
Embed Size (px)
Citation preview
1 | P a g e
Sewage Treatment Plant and
Tertiary Treatment Service Report
Xtratherm,
Liscarton Industrial Estate,
Kells Road,
Navan,
Co. Meath
Reference: 0060. STP Service Report
File reference __________________
For
insp
ectio
n pur
pose
s only
.
Conse
nt of
copy
right
owne
r req
uired
for a
ny ot
her u
se.
EPA Export 15-04-2019:03:28:24
2 | P a g e
Client: Xtratherm
Date: 10.12.18
Address: Liscarton Industrial Estate, Kells Rd, Navan, Co. Meath
Reference: 0060. STP Service Report
Contract Type: STP, Puraflo Modules, Pump Chamber and associated pipe work
Service Period: 01/01/18- 31/12/18
For
insp
ectio
n pur
pose
s only
.
Conse
nt of
copy
right
owne
r req
uired
for a
ny ot
her u
se.
EPA Export 15-04-2019:03:28:24
3 | P a g e
Items included in Service agreement
- Klargester STP & Pumping station
- Bord na Mona pump chamber
- Bord na Mona Puraflo peat filter modules
- Gravity Percolation
- Toilet Pump Chamber
- Flow Meter
This Service Contract includes the following:
- Entire Sewage Treatment will be inspected on four separate occasions for the duration
of the Service Contract.
- Following each inspection, a written report will be provided confirming the status of
all electrical working parts, filter media and percolation area.
- This Service contract includes the implementation of the site visit and minor
adjustments, which do not involve additional materials and labour.
- The Service Contract covers the inspection of all installed equipment.
- Replacement of any installed units, including electrical, pipe connections etc after the
initial 12 months of this contract will not be covered.
- The Service Contract includes e-mail and telephone correspondence throughout the
terms of the contract, should issues arise.
Checked on: 10.12.18 by Daniel McManus
Checked:
Klargester treatment RBC is working & rotating. slight odour due to new vents.
Stp first discharge pump OK.
Stp second discharge pump – float switch and pump working with no defects
Bord na mona peat modules – all pipework clear with no blockages and very little
sign of ponding in modules. No smell evident either.
Gravity percolation network: no sign of ponding or breakout.
Toilet pump chamber in good working condition, float switch and pump working ok.
Comments:
- Peat in bord na mona modules to be continued to be loosened up to avoid over
compaction and ponding on every service call out. This will help with the life span of
the bord na Mona modules.
For
insp
ectio
n pur
pose
s only
.
Conse
nt of
copy
right
owne
r req
uired
for a
ny ot
her u
se.
EPA Export 15-04-2019:03:28:24
4 | P a g e
The Sewage Treatment Plant is suitable for the treatment of Sewage, wash basins, sinks from
the dwelling only. It is not suitable for the collection and treatment of surface water, rain
water, grease or additional loadings to that originally specified.
Excessive loading of detergents, cleaners into the Sewage Treatment Plant are not permitted
at any time.
Desludging periods are dependent on usage. However, it is recommended to desludge on an
annual basis. Mitchell Environmental will advise on desludging requirements as part of the
Service contract.
It is advisable that Mitchell Environmental should have access to the Sewage Treatment Plant
and control panels at all times if possible.
It is not suitable to plant trees or deep-rooted shrubs on the surface of the percolation area.
Signed for the Company
______________
Gordon Mitchell
For
insp
ectio
n pur
pose
s only
.
Conse
nt of
copy
right
owne
r req
uired
for a
ny ot
her u
se.
EPA Export 15-04-2019:03:28:24
5 | P a g e
Klargester unit - working ok, slight odour evident.
For
insp
ectio
n pur
pose
s only
.
Conse
nt of
copy
right
owne
r req
uired
for a
ny ot
her u
se.
EPA Export 15-04-2019:03:28:24
6 | P a g e
The First Sewage Discharge pumping station:
We advise that this pumping station is redirected during the next upgrade works stage
due to an intermittent blockage in the rising main.
For
insp
ectio
n pur
pose
s only
.
Conse
nt of
copy
right
owne
r req
uired
for a
ny ot
her u
se.
EPA Export 15-04-2019:03:28:25
7 | P a g e
Portable toilet pump chamber in good working condition:
For
insp
ectio
n pur
pose
s only
.
Conse
nt of
copy
right
owne
r req
uired
for a
ny ot
her u
se.
EPA Export 15-04-2019:03:28:25
8 | P a g e
Pump chamber to Bord na Mona Modules- OK
For
insp
ectio
n pur
pose
s only
.
Conse
nt of
copy
right
owne
r req
uired
for a
ny ot
her u
se.
EPA Export 15-04-2019:03:28:25
9 | P a g e
Bord na Mona Peat Modules in good condition
For
insp
ectio
n pur
pose
s only
.
Conse
nt of
copy
right
owne
r req
uired
for a
ny ot
her u
se.
EPA Export 15-04-2019:03:28:25