20
CURVES BX-560G Series HSC 3 & HSC-S Horizontal Split Case Base Mounted – Double Suction 50 Cycle Performance Curves Part of Equipment Selection Programs

Series HSC & HSC-S - Xylem Inc....Series HSC3 & HSC-S Horizontal Split Case Base Mounted – Double Suction 50 Cycle Performance Curves Part of Equipment Selection Programs 2 TABLE

  • Upload
    others

  • View
    14

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Series HSC & HSC-S - Xylem Inc....Series HSC3 & HSC-S Horizontal Split Case Base Mounted – Double Suction 50 Cycle Performance Curves Part of Equipment Selection Programs 2 TABLE

CURVESBX-560G

Series HSC3 & HSC-SHorizontal Split CaseBase Mounted – Double Suction50 CyclePerformance Curves

Part of

Equipment Selection Programs

Page 2: Series HSC & HSC-S - Xylem Inc....Series HSC3 & HSC-S Horizontal Split Case Base Mounted – Double Suction 50 Cycle Performance Curves Part of Equipment Selection Programs 2 TABLE

2

TABLE OF CONTENTS

USEFUL PUMP FORMULAS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2

2900 RPM PUMP CURVES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3

1450 RPM PUMP CURVES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5

Pressure = Head (Feet) x Specific Gravity(PSI) 2.31

Head = Pressure (PSI) x 2.31(Feet) Specific Gravity

Vacuum = Dynamic Suction Lift (Feet) x .883 (Inches of Mercury) x Specific Gravity

Horsepower = GPM x Head (Feet) x Specific Gravity(Brake) 3960 x Pump Efficiency

Horsepower = GPM x Head (Feet) x Specific Gravity(Water) 3960

Efficiency = Horsepower (Water) x 100 Per Cent(Pump) Horsepower (Brake)

NPSH = Atmospheric Pressure - Vapor Pressure + Total Suction Head(Available)

GPM Capacity Ft. Head BHP

ImpellerDiameterChange

SpeedChange

USEFUL PUMP FORMULAS

Affinity Laws: Effect of change of speed or impeller diameter on centrifugal pumps.

Where Q = GPM, H = Head, P = BHP, D = Impeller Dia., RPM = Pump Speed

Q2 = Q1D2

D1

Q2 = Q1RPM2

RPM1H2 = ( )2

H1RPM2

RPM1P2 = ( )3

P1RPM2

RPM1

P2 = ( )3

P1D2

D1H2 = ( )2

H1D2

D1

Page 3: Series HSC & HSC-S - Xylem Inc....Series HSC3 & HSC-S Horizontal Split Case Base Mounted – Double Suction 50 Cycle Performance Curves Part of Equipment Selection Programs 2 TABLE

2900 RPM PUMP CURVES

3

BX-560G

AREAINLET

DIA.MIN.

VANESNO. OF

IMPELLER DATARPMSPEED

SPHEREMAX.

DIA.MAX.

NO.IMP.

PUMPCURVE

0 10 20 30 40 50 60 700

5

10

15

20

10

20

30

40

50

60

70

80

90

100

0 50 100 150 200 250 300

0

50

100

150

200

250

300

(M)(Ft)

TOTALHEAD

(M3/H)

(GPM)FLOW

kW

AM-8077-4-50 2x3x11S HSC3 & HSC-S Series 2945

P-3265 6

279mm 140mm

6.35mm 49.7cm2

Minimum recommended flow is 40% B.E.P.

279mm A279mm A

261mm B261mm B

243mm C243mm C

226mm D226mm D

208mm E208mm E

190mm F190mm F

172mm G172mm G154mm H154mm H

140mm I140mm I

A A

B B C C

D D E E

F F G G H H I I

58585757

5757

5555

5555

5353

5353

5050

5050

4747

4747

4343

4343

3838

3838

3232

2.12.18.08.0

2.42.47.77.7

3.33.36.86.8

5.25.24.94.9

7.97.92.22.2

NPSH REQ’D (METERS)NPSH REQ’D (METERS)SUCTION LIFT (METERS)SUCTION LIFT (METERS)

AREAINLET

DIA.MIN.

VANESNO. OF

IMPELLER DATARPMSPEED

SPHEREMAX.

DIA.MAX.

NO.IMP.

PUMPCURVE

0 10 20 30 40 50 60 70 80 900

10

20

30

10

20

30

40

50

60

70

80

90

100

110

0 50 100 150 200 250 300 350

50

100

150

200

250

300

350

(M)(Ft)

TOTALHEAD

(M3/H)

(GPM)FLOW

kW

AM-8079-4-50 2x3x11L HSC3 & HSC-S Series 2945

P-3280 6

279mm 140mm

9.65mm 61.9cm2

Minimum recommended flow is 40% B.E.P.

279mm A279mm A

261mm B261mm B

243mm C243mm C

226mm D226mm D

208mm E208mm E

190mm F190mm F

172mm G172mm G

154mm H154mm H140mm I140mm I

A A B B

C C D D

E E F F G G H H I I

6464

6464

6363

6363

6161

6161

5858

5858

5454

5454

4949

4949

4343

4343

3636

2.12.17.97.9

3.43.46.76.7

6.26.23.93.9

NPSH REQ D (METERS)NPSH REQ D (METERS)SUCTION LIFT (METERS)SUCTION LIFT (METERS)

Bell & Gossett

Bell & Gossett

Page 4: Series HSC & HSC-S - Xylem Inc....Series HSC3 & HSC-S Horizontal Split Case Base Mounted – Double Suction 50 Cycle Performance Curves Part of Equipment Selection Programs 2 TABLE

2900 RPM PUMP CURVES

4

BX-560G

AREAINLET

DIA.MIN.

VANESNO. OF

IMPELLER DATARPMSPEED

SPHEREMAX.

DIA.MAX.

NO.IMP.

PUMPCURVE

0 50 100 150 200 250 300 3500

25

50

75

100

25

50

75

100

125

0 250 500 750 1000 1250 1500

0

100

200

300

400

(M)(Ft)

TOTALHEAD

(M3/H)

(GPM)FLOW

kW

AM-8450-3-50 4x6x10M HSC3 & HSC-S Series 2960

P-3766-1 6

305mm 165mm

12.70mm 103cm2

Minimum recommended flow is 40% B.E.P.

304mm A304mm A

269mm B269mm B

233mm C233mm C

198mm D198mm D165mm E165mm E

A A

B B C C

D D E E

78787878

7676

7676

7373

7373

6868

6868

6262

6262

4.24.25.95.9

2.82.87.37.3

5.45.44.74.7

NPSH REQ’D (METERS)NPSH REQ’D (METERS)SUCTION LIFT (METERS)SUCTION LIFT (METERS)

Bell & Gossett

AREAINLET

DIA.MIN.

VANESNO. OF

IMPELLER DATARPMSPEED

SPHEREMAX.

DIA.MAX.

NO.IMP.

PUMPCURVE

0 100 200 300 400 500 600 700 8000

50

100

150

200

25

50

75

100

125

150

0 500 1000 1500 2000 2500 3000

100

200

300

400

(M)(Ft)

TOTALHEAD

(M3/H)

(GPM)FLOW

kW

AM-8453-4-50 6x8x12M HSC3 & HSC-S Series 2970

P-3678-1 5

325mm 165mm

22.10mm 132cm2

at this speed.Standard on this pumpNOTE: 4140 Shaft material is

Minimum recommended flow is 50% B.E.P.

325mm A325mm A302mm B302mm B279mm C279mm C256mm D256mm D233mm E233mm E210mm F210mm F187mm G187mm G165mm H165mm H

A A B B

C C D D

E E F F

G G H H

8383

8383

8282

8282

7979

7979

7575

7575

7070

7070

63635353

3.53.56.66.6

4.74.75.45.4

6.66.63.53.5

NPSH REQ’D (METERS)NPSH REQ’D (METERS)SUCTION LIFT (METERS)SUCTION LIFT (METERS)

Bell & Gossett

Page 5: Series HSC & HSC-S - Xylem Inc....Series HSC3 & HSC-S Horizontal Split Case Base Mounted – Double Suction 50 Cycle Performance Curves Part of Equipment Selection Programs 2 TABLE

1450 RPM PUMP CURVES

5

BX-560G

AREAINLET

DIA.MIN.

VANESNO. OF

IMPELLER DATARPMSPEED

SPHEREMAX.

DIA.MAX.

NO.IMP.

PUMPCURVE

0 5 10 15 20 25 30 35 40 450

1

2

3

4

5

10

15

20

25

0 25 50 75 100 125 150 175

0

25

50

75

(M)(Ft)

TOTALHEAD

(M3/H)

(GPM)FLOW

kW

AM-8078-5-50 2x3x11S HSC3 & HSC-S Series 1450

P-3265 6

279mm 140mm

6.35mm 49.7cm2

Minimum recommended flow is 40% B.E.P.

279mm A279mm A

243mm B243mm B

208mm C208mm C

172mm D172mm D139mm E139mm E

A A

B B

C C D D E E

5353 53535151

5151

4949

4949

4747

4747

4343

4343

39393333

1.21.28.88.8

1.81.88.28.2

2.12.17.97.9

2.72.77.37.3

3.03.07.07.0

NPSH REQ’D (METERS)NPSH REQ’D (METERS)SUCTION LIFT (METERS)SUCTION LIFT (METERS)

AREAINLET

DIA.MIN.

VANESNO. OF

IMPELLER DATARPMSPEED

SPHEREMAX.

DIA.MAX.

NO.IMP.

PUMPCURVE

0 5 10 15 20 25 30 35 40 45 500

1

2

3

4

5

6

5

10

15

20

25

30

0 25 50 75 100 125 150 175 200 225

0

25

50

75

(M)(Ft)

TOTALHEAD

(M3/H)

(GPM)FLOW

kW

AM-8080-5-50 2x3x11L HSC3 & HSC-S Series 1455

P-3280 6

279mm 140mm

9.65mm 61.9cm2

Minimum recommended flow is 40% B.E.P.

279mm A279mm A

243mm B243mm B

208mm C208mm C

172mm D172mm D

139mm E139mm E

A A

B B

C C D D

E E

6262 62626161

61616060

6060

5858

5858

5555

5555

505045453838

0.70.79.49.4

1.21.28.98.9

2.12.18.08.0

NPSH REQ’D (METERS)NPSH REQ’D (METERS)SUCTION LIFT (METERS)SUCTION LIFT (METERS)

Bell & Gossett

Bell & Gossett

Page 6: Series HSC & HSC-S - Xylem Inc....Series HSC3 & HSC-S Horizontal Split Case Base Mounted – Double Suction 50 Cycle Performance Curves Part of Equipment Selection Programs 2 TABLE

1450 RPM PUMP CURVES

6

BX-560G

PERFORMANCE CHARACTERISTIC CHART

TO

TAL

HE

AD

, FE

ET

TO

TAL

HE

AD

, ME

TE

RS

CAPACITY, CUBIC METERS/HR

CAPACITY, U.S. GALLONS PER MINUTE

NP

SH

, ME

TE

RS

NP

SH

, FE

ET

80

70

60

50

40

30

20

10

0

20

15

10

5

00

0

0

520

10

050 100 150 200 250

200 400 600 800 1000 1200

AREAINLET

DIA.MIN.

VANESNO. OF

IMPELLER DATARPMSPEED

SPHEREMAX.

DIA.MAX.

NO.IMP.

PUMPCURVE

0 20 40 60 80 100 120 140 1600

2.5

5

7.5

10

12.5

15

0

5

10

15

20

25

30

0 100 200 300 400 500 600 700

0

25

50

75

100

(M)(Ft)

TOTALHEAD

(M3/H)

(GPM)FLOW

kW

AM-8451-3-50 4x6x10M HSC3 & HSC-S Series 1460

P-3766-1 6

305mm 165mm

12.70mm 103cm2

Minimum recommended flow is 40% B.E.P.

304mm A304mm A

276mm B276mm B

248mm C248mm C

220mm D220mm D

193mm E193mm E

165mm F165mm F

A A

B B C C

D D E E

F F

76767676

7575

7575

7474

7474

7171

7171

6868

6868

6464

6464

5858

5858

1.01.09.19.1

1.51.58.68.6

2.02.08.18.1

NPSH REQ’D (METERS)NPSH REQ’D (METERS)SUCTION LIFT (METERS)SUCTION LIFT (METERS)

Bell & Gossett

4x6x10A1450 R.P.M.

Page 7: Series HSC & HSC-S - Xylem Inc....Series HSC3 & HSC-S Horizontal Split Case Base Mounted – Double Suction 50 Cycle Performance Curves Part of Equipment Selection Programs 2 TABLE

1450 RPM PUMP CURVES

7

BX-560G

PERFORMANCE CHARACTERISTIC CHART

TO

TAL

HE

AD

, FE

ET

TO

TAL

HE

AD

, ME

TE

RS

CAPACITY, CUBIC METERS/HR

CAPACITY, U.S. GALLONS PER MINUTE

NP

SH

, ME

TE

RS

NP

SH

, FE

ET

80

70

60

50

40

30

20

10

0

35

15

10

5

00

0

0

520

10

050 100 150 200 300

100 400 600 800 1000 1100200 300 500 700 900

20

25

30

40

90

100

110

120

130

140

10

30

AREAINLET

DIA.MIN.

VANESNO. OF

IMPELLER DATARPMSPEED

SPHEREMAX.

DIA.MAX.

NO.IMP.

PUMPCURVE

0 50 100 150 200 2500

10

20

30

40

0

5

10

15

20

25

30

35

40

45

0 250 500 750 1000

0

25

50

75

100

125

150

(M)(Ft)

TOTALHEAD

(M3/H)

(GPM)FLOW

kW

AM-8699-2-50 4x6x12XL HSC3 & HSC-S Series 1470

P-4219 7

351mm 198mm

9.39mm 183cm2

Minimum recommended flow is 40% B.E.P.

350mm A350mm A

325mm B325mm B

299mm C299mm C

274mm D274mm D

248mm E248mm E

223mm F223mm F198mm G198mm G

A A B B

C C D D

E E F F G G

7979

7979

7878

7878

7575

7575

7272

7272

6868

6868

6161

6161

1.71.78.48.4

3.83.86.36.3

10.010.00.10.1

NPSH REQ D (METERS)NPSH REQ D (METERS)SUCTION LIFT (METERS)SUCTION LIFT (METERS)

Bell & Gossett

4x6x12A1450 R.P.M.

Page 8: Series HSC & HSC-S - Xylem Inc....Series HSC3 & HSC-S Horizontal Split Case Base Mounted – Double Suction 50 Cycle Performance Curves Part of Equipment Selection Programs 2 TABLE

1450 RPM PUMP CURVES

8

BX-560G

PERFORMANCE CHARACTERISTIC CHART

TO

TAL

HE

AD

, FE

ET

TO

TAL

HE

AD

, ME

TE

RS

CAPACITY, CUBIC METERS/HR

CAPACITY, U.S. GALLONS PER MINUTE

NP

SH

, ME

TE

RS

NP

SH

, FE

ET

80

60

40

20

0

40

10

00

0

0

20

10

0

50 100 150 200 300

600 1200 1400 1600200 400 800 1000

20

30

50

100

120

140

160

40

250 350

20

AREAINLET

DIA.MIN.

VANESNO. OF

IMPELLER DATARPMSPEED

SPHEREMAX.

DIA.MAX.

NO.IMP.

PUMPCURVE

0 20 40 60 80 100 120 140 160 180 2000

5

10

15

20

0

5

10

15

20

25

30

35

40

45

0 100 200 300 400 500 600 700 800

0

25

50

75

100

125

(M)(Ft)

TOTALHEAD

(M3/H)

(GPM)FLOW

kW

AM-8087-4-50 4x6x14L HSC3 & HSC-S Series 1470

P-3276-1 6

351mm 178mm

17.27mm 148cm2

Minimum recommended flow is 40% B.E.P.

350mm A350mm A

325mm B325mm B

299mm C299mm C

274mm D274mm D

248mm E248mm E

223mm F223mm F198mm G198mm G177mm H177mm H

A A

B B

C C D D

E E F F G G H H

77777777

7676

7676

7474

7474

72726868646459595252

1.81.88.28.2

2.42.47.67.6

3.03.07.07.0

5.55.54.64.6

NPSH REQ’D (METERS)NPSH REQ’D (METERS)SUCTION LIFT (METERS)SUCTION LIFT (METERS)

Bell & Gossett

4x6x14A1450 R.P.M.

Page 9: Series HSC & HSC-S - Xylem Inc....Series HSC3 & HSC-S Horizontal Split Case Base Mounted – Double Suction 50 Cycle Performance Curves Part of Equipment Selection Programs 2 TABLE

1450 RPM PUMP CURVESBX-560G

9

PERFORMANCE CHARACTERISTIC CHART

TO

TAL

HE

AD

, FE

ET

TO

TAL

HE

AD

, ME

TE

RS

CAPACITY, CUBIC METERS/HR

CAPACITY, U.S. GALLONS PER MINUTE

NP

SH

, ME

TE

RS

NP

SH

, FE

ET

50

40

30

20

0

20

5

00

0

0

205

0100 200 300 400

1000 2000 2500500 1500

10

15

25

60

70

80

90

30

500

10

10 10

Bell & Gossett

6x8x10A1450 R.P.M.

Page 10: Series HSC & HSC-S - Xylem Inc....Series HSC3 & HSC-S Horizontal Split Case Base Mounted – Double Suction 50 Cycle Performance Curves Part of Equipment Selection Programs 2 TABLE

1450 RPM PUMP CURVES

10

BX-560G

AREAINLET

DIA.MIN.

VANESNO. OF

IMPELLER DATARPMSPEED

SPHEREMAX.

DIA.MAX.

NO.IMP.

PUMPCURVE

0 50 100 150 200 250 300 350 400 4500

10

20

30

40

0

5

10

15

20

25

30

35

0 200 400 600 800 1000 1200 1400 1600 1800

0

25

50

75

100

(M)(Ft)

TOTALHEAD

(M3/H)

(GPM)FLOW

kW

AM-8025-6-50 6x8x12L HSC3 & HSC-S Series 1480

P-2869-1 7

325mm 178mm

25.40mm 251cm2

Minimum recommended flow is 40% B.E.P.

325mm A325mm A

297mm B297mm B

269mm C269mm C

241mm D241mm D

213mm E213mm E

177mm F177mm F

A A B B

C C D D E E F F

83838383

8282

8282

8080

8080

7777

7777

7272

7272

6666

6666

5858

5858

2.32.37.87.8

3.03.07.17.1

3.53.56.66.6

4.74.75.45.4

NPSH REQ’D (METERS)NPSH REQ’D (METERS)SUCTION LIFT (METERS)SUCTION LIFT (METERS)

Bell & Gossett

AREAINLET

DIA.MIN.

VANESNO. OF

IMPELLER DATARPMSPEED

SPHEREMAX.

DIA.MAX.

NO.IMP.

PUMPCURVE

0 50 100 150 200 250 300 350 4000

5

10

15

20

25

30

5

10

15

20

25

30

35

0 250 500 750 1000 1250 1500

0

25

50

75

100

(M)(Ft)

TOTALHEAD

(M3/H)

(GPM)FLOW

kWAM-8454-4 6x8x12M HSC3 & HSC-S Series 1470

P-3678-1 5

325mm 165mm

22.10mm 132cm2

Minimum recommended flow is 50% B.E.P.

325mm A325mm A

302mm B302mm B

279mm C279mm C256mm D256mm D

233mm E233mm E210mm F210mm F187mm G187mm G165mm H165mm H

A A

B B C C

D D E E

F F G G

H H

8383

8383

8181

8181

7979

7979

7575

7575

7070

7070

6262

6262

5353

1.31.38.88.8

1.81.88.38.3

2.52.57.67.6

4.84.85.35.3

NPSH REQ’D (METERS)NPSH REQ’D (METERS)SUCTION LIFT (METERS)SUCTION LIFT (METERS)

Bell & Gossett

Page 11: Series HSC & HSC-S - Xylem Inc....Series HSC3 & HSC-S Horizontal Split Case Base Mounted – Double Suction 50 Cycle Performance Curves Part of Equipment Selection Programs 2 TABLE

1450 RPM PUMP CURVES

11

BX-560G

AREAINLET

DIA.MIN.

VANESNO. OF

IMPELLER DATARPMSPEED

SPHEREMAX.

DIA.MAX.

NO.IMP.

PUMPCURVE

0 50 100 150 200 250 300 350 400 450 500 5500

10

20

30

40

0

5

10

15

20

25

30

35

40

0 250 500 750 1000 1250 1500 1750 2000 2250

0

25

50

75

100

125

(M)(Ft)

TOTALHEAD

kW

AM-8702-2-50 6x8x12XL HSC3 & HSC-S Series 1480

P-4220 7

340mm 203mm

25.40mm 262cm2

Minimum recommended flow is 40% B.E.P.

340mm A340mm A

318mm B318mm B

294mm C294mm C

272mm D272mm D248mm E248mm E

225mm F225mm F

203mm G203mm G

A A

B B

C C D D

E E F F

G G

8484

8484

8282

8282

7979

7979

7575

7575

7070

7070

6363

6363

3.03.07.17.1

4.04.06.16.1

6.06.04.14.1

9.09.01.11.1

11.011.0--

NPSH REQ’D (METERS)NPSH REQ’D (METERS)SUCTION LIFT (METERS)SUCTION LIFT (METERS)

(M3/H)

(GPM)FLOW

AREAINLET

DIA.MIN.

VANESNO. OF

IMPELLER DATARPMSPEED

SPHEREMAX.

DIA.MAX.

NO.IMP.

PUMPCURVE

0 50 100 150 200 250 300 350 400 450 5000

5

10

15

20

25

30

0

5

10

15

20

25

30

35

0 250 500 750 1000 1250 1500 1750 2000 2250

0

25

50

75

100

(M)(Ft)

TOTALHEAD

(M3/H)

(GPM)FLOW

kW

AM-7492-5-50 6x8x13 HSC3 & HSC-S Series 1470

08-1668-1 7

333mm 178mm

25.40mm 286cm2

Minimum recommended flow is 40% B.E.P.

332mm A332mm A

307mm B307mm B

281mm C281mm C

256mm D256mm D

231mm E231mm E205mm F205mm F177mm G177mm G

A A

B B

C C D D

E E F F

G G

8383

8181

7777

7777

7373

7373

6767

6767

5959

5959

2.32.37.87.8

3.53.56.66.6

NPSH REQ’D (METERS)NPSH REQ’D (METERS)SUCTION LIFT (METERS)SUCTION LIFT (METERS)

Bell & Gossett

Bell & Gossett

Page 12: Series HSC & HSC-S - Xylem Inc....Series HSC3 & HSC-S Horizontal Split Case Base Mounted – Double Suction 50 Cycle Performance Curves Part of Equipment Selection Programs 2 TABLE

1450 RPM PUMP CURVES

12

BX-560G

AREAINLET

DIA.MIN.

VANESNO. OF

IMPELLER DATARPMSPEED

SPHEREMAX.

DIA.MAX.

NO.IMP.

PUMPCURVE

0 50 100 150 200 250 300 3500

25

50

0

5

10

15

20

25

30

35

40

45

50

55

60

0 250 500 750 1000 1250 1500

0

25

50

75

100

125

150

175

200

(M)(Ft)

TOTALHEAD

(M3/H)

(GPM)FLOW

kW

AM-7497-5-50 6x8x17L HSC3 & HSC-S Series 1480

08-1713-2 6

432mm 254mm

12.70mm 250cm2

Minimum recommended flow is 40% B.E.P.

431mm A431mm A

406mm B406mm B

381mm C381mm C

355mm D355mm D

330mm E330mm E

304mm F304mm F

279mm G279mm G

254mm H254mm H

A A B B

C C D D E E F F G G H H

78787777

7777

7676

7676

7474

7474

7272

7272

6868

6868

6464

6464

58585050

2.42.47.67.6

3.43.46.76.7

4.94.95.25.2

6.76.73.43.4

NPSH REQ’D (METERS)NPSH REQ’D (METERS)SUCTION LIFT (METERS)SUCTION LIFT (METERS)

Bell & Gossett

AREAINLET

DIA.MIN.

VANESNO. OF

IMPELLER DATARPMSPEED

SPHEREMAX.

DIA.MAX.

NO.IMP.

PUMPCURVE

0 50 100 150 200 250 300 350 400 4500

25

50

0

5

10

15

20

25

30

35

40

45

50

55

60

0 250 500 750 1000 1250 1500 1750

0

25

50

75

100

125

150

175

(M)(Ft)

TOTALHEAD

(M3/H)

(GPM)FLOW

kW

AM-8093-4-50 6x8x17M HSC3 & HSC-S Series 1480

P-3248 6

432mm 254mm

11.94mm 190cm2

Minimum recommended flow is 40% B.E.P.

431mm A431mm A

406mm B406mm B

381mm C381mm C

355mm D355mm D

330mm E330mm E

304mm F304mm F

279mm G279mm G

254mm H254mm H

A A B B C C D D

E E F F G G H H

8080

79797878

7575

7575

7272

7272

6868

6868

6262

6262

5454

5454

2.72.77.37.3

4.64.65.55.5

NPSH REQ’D (METERS)NPSH REQ’D (METERS)SUCTION LIFT (METERS)SUCTION LIFT (METERS)

Bell & Gossett

Page 13: Series HSC & HSC-S - Xylem Inc....Series HSC3 & HSC-S Horizontal Split Case Base Mounted – Double Suction 50 Cycle Performance Curves Part of Equipment Selection Programs 2 TABLE

1450 RPM PUMP CURVES

13

BX-560G

AREAINLET

DIA.MIN.

VANESNO. OF

IMPELLER DATARPMSPEED

SPHEREMAX.

DIA.MAX.

NO.IMP.

PUMPCURVE

0 100 200 300 400 500 600 7005

10

15

20

25

30

35

40

0

5

10

15

20

25

30

35

0 500 1000 1500 2000 2500 3000

0

25

50

75

100

(M)(Ft)

TOTALHEAD

(M3/H)

(GPM)FLOW

kWAM-7493-5-50 8x8x12 HSC3 & HSC-S Series 1480

P-3091 7

325mm 203mm

28.70mm 399cm2

Minimum recommended flow is 40% B.E.P.

325mm A325mm A

304mm B304mm B

284mm C284mm C

264mm D264mm D243mm E243mm E223mm F223mm F203mm G203mm G

A A

B B

C C D D

E E F F

G G

8383

8383

8181

8181

7777

7777

7272

7272

6666

6666

5959

5959

4949

2.12.18.08.0

3.03.07.17.1

4.34.35.85.8

6.16.14.04.0

NPSH REQ’D (METERS)NPSH REQ’D (METERS)SUCTION LIFT (METERS)SUCTION LIFT (METERS)

AREAINLET

DIA.MIN.

VANESNO. OF

IMPELLER DATARPMSPEED

SPHEREMAX.

DIA.MAX.

NO.IMP.

PUMPCURVE

0 50 100 150 200 250 300 350 400 450 500 5500

25

50

75

100

0

10

20

30

40

50

60

70

0 250 500 750 1000 1250 1500 1750 2000 2250

0

50

100

150

200

(M)(Ft)

TOTALHEAD

kW

AM-7498-5-50 8x8x17 HSC3 & HSC-S Series 1480

P-3984 7

450mm 254mm

24.89mm 259cm2

Minimum recommended flow is 40% B.E.P.

449mm A449mm A

421mm B421mm B

393mm C393mm C365mm D365mm D337mm E337mm E309mm F309mm F281mm G281mm G254mm H254mm H

A A B B

C C D D

E E F F G G H H

80807979

7878

7676

7676

7373

7373

7070656559595050

4.24.25.95.9

3.73.76.46.4

5.95.94.24.2

NPSH REQ’D (METERS)NPSH REQ’D (METERS)SUCTION LIFT (METERS)SUCTION LIFT (METERS)

(M3/H)

(GPM)FLOW

Bell & Gossett

Bell & Gossett

Page 14: Series HSC & HSC-S - Xylem Inc....Series HSC3 & HSC-S Horizontal Split Case Base Mounted – Double Suction 50 Cycle Performance Curves Part of Equipment Selection Programs 2 TABLE

1450 RPM PUMP CURVES

14

BX-560G

AREAINLET

DIA.MIN.

VANESNO. OF

IMPELLER DATARPMSPEED

SPHEREMAX.

DIA.MAX.

NO.IMP.

PUMPCURVE

0 100 200 300 400 500 6000

10

20

30

40

0

5

10

15

20

25

30

35

0 500 1000 1500 2000 2500

0

25

50

75

100

(M)(Ft)

TOTALHEAD

(M3/H)

(GPM)FLOW

kW

AM-7494-7-50 8x10x12S HSC3 & HSC-S Series 1480

08-1701-70 6

325mm 203mm

35.56mm 406cm2

Minimum recommended flow is 40% B.E.P.

325mm A325mm A304mm B304mm B284mm C284mm C264mm D264mm D243mm E243mm E223mm F223mm F203mm G203mm G

A A B B

C C D D

E E F F G G

8585

8585

8383

8383

8080

8080

7777

7777

7272676760605252

2.32.37.87.8

4.74.75.45.4

7.07.03.13.1

NPSH REQ’D (METERS)NPSH REQ’D (METERS)SUCTION LIFT (METERS)SUCTION LIFT (METERS)

AREAINLET

DIA.MIN.

VANESNO. OF

IMPELLER DATARPMSPEED

SPHEREMAX.

DIA.MAX.

NO.IMP.

PUMPCURVE

0 100 200 300 400 500 600 70010

20

30

40

50

0

5

10

15

20

25

30

35

40

0 500 1000 1500 2000 2500 3000

0

25

50

75

100

125

(M)(Ft)

TOTALHEAD

(M3/H)

(GPM)FLOW

kW

AM-8273-4-50 8x10x12L HSC3 & HSC-S Series 1480

P-3063 6

325mm 216mm

37.34mm 370cm2

Minimum recommended flow is 40% B.E.P.

325mm A325mm A

304mm B304mm B284mm C284mm C264mm D264mm D243mm E243mm E215mm F215mm F

A A

B B

C C

D D E E

F F

8686

8484

8484

8181

8181

777772726767606052524242

2.12.18.08.0

2.32.37.87.8

3.53.56.66.6

4.74.75.45.4

7.07.03.13.1

NPSH REQ’D (METERS)NPSH REQ’D (METERS)SUCTION LIFT (METERS)SUCTION LIFT (METERS)

Bell & Gossett

Bell & Gossett

Page 15: Series HSC & HSC-S - Xylem Inc....Series HSC3 & HSC-S Horizontal Split Case Base Mounted – Double Suction 50 Cycle Performance Curves Part of Equipment Selection Programs 2 TABLE

1450 RPM PUMP CURVES

15

BX-560G

AREAINLET

DIA.MIN.

VANESNO. OF

IMPELLER DATARPMSPEED

SPHEREMAX.

DIA.MAX.

NO.IMP.

PUMPCURVE

0 100 200 300 400 500 600 700 800 9000

25

50

75

100

125

0

10

20

30

40

50

60

70

0 500 1000 1500 2000 2500 3000 3500

0

50

100

150

200

(M)(Ft)

TOTALHEAD

(M3/H)

(GPM)FLOW

kW

AM-7499-7-50 8x10x17S HSC3 & HSC-S Series 1485

08-1626-2 7

450mm 254mm

24.64mm 371cm2

Minimum recommended flow is 40% B.E.P.

449mm A449mm A

419mm B419mm B

388mm C388mm C358mm D358mm D327mm E327mm E297mm F297mm F

254mm G254mm G

A A

B B C C

D D E E

F F G G

8383

8181

8181

7878

7878

7575

7575

7070

7070

6464

6464

5656

5656

1.81.88.28.2

2.42.47.67.6

3.43.46.76.7

4.34.35.85.8

NPSH REQ’D (METERS)NPSH REQ’D (METERS)SUCTION LIFT (METERS)SUCTION LIFT (METERS)

AREAINLET

DIA.MIN.

VANESNO. OF

IMPELLER DATARPMSPEED

SPHEREMAX.

DIA.MAX.

NO.IMP.

PUMPCURVE

0 100 200 300 400 500 600 700 8000

25

50

75

100

125

0

10

20

30

40

50

60

0 500 1000 1500 2000 2500 3000 3500

0

50

100

150

200

(M)(Ft)

TOTALHEAD

(M3/H)

(GPM)FLOW

kW

AM-8272-4-50 8x10x17L HSC3 & HSC-S Series 1485

P-2965-3 5

439mm 305mm

29.46mm 422cm2

Minimum recommended flow is 40% B.E.P.

439mm A439mm A419mm B419mm B398mm C398mm C375mm D375mm D353mm E353mm E330mm F330mm F304mm G304mm G

A A

B B C C

D D E E

F F G G

85858585

8484

8484

8282797976767171646456564646

2.82.87.37.3

3.53.56.66.6

4.54.55.65.6

NPSH REQ’D (METERS)NPSH REQ’D (METERS)SUCTION LIFT (METERS)SUCTION LIFT (METERS)

Bell & Gossett

Bell & Gossett

Page 16: Series HSC & HSC-S - Xylem Inc....Series HSC3 & HSC-S Horizontal Split Case Base Mounted – Double Suction 50 Cycle Performance Curves Part of Equipment Selection Programs 2 TABLE

1450 RPM PUMP CURVES

16

BX-560G

AREAINLET

DIA.MIN.

VANESNO. OF

IMPELLER DATARPMSPEED

SPHEREMAX.

DIA.MAX.

NO.IMP.

PUMPCURVE

0 100 200 300 400 500 600 700 8000

50

100

150

200

10

20

30

40

50

60

70

80

90

0 500 1000 1500 2000 2500 3000

50

100

150

200

250

300

(M)(Ft)

TOTALHEAD

(M3/H)

(GPM)FLOW

kW

AM-8630-2-50 8x10x20S HSC3 & HSC-S Series 1485

P-3819 6

513mm 305mm

13.46mm 441cm2

Minimum recommended flow is 40% B.E.P.

513mm A513mm A487mm B487mm B462mm C462mm C436mm D436mm D411mm E411mm E386mm F386mm F360mm G360mm G335mm H335mm H304mm I304mm I

A A B B C C D D E E F F G G H H I I

8080

7979

7979

7878

7878

7575

7575

7171

7171

6666

6666

60605151

1.51.58.68.6

2.12.18.08.0

3.03.07.17.1

4.64.65.55.5

NPSH REQ’D (METERS)NPSH REQ’D (METERS)SUCTION LIFT (METERS)SUCTION LIFT (METERS)

AREAINLET

DIA.MIN.

VANESNO. OF

IMPELLER DATARPMSPEED

SPHEREMAX.

DIA.MAX.

NO.IMP.

PUMPCURVE

0 100 200 300 400 500 600 700 800 9000

50

100

150

200

15

25

35

45

55

65

75

85

0 500 1000 1500 2000 2500 3000 3500 4000

0

50

100

150

200

250

300

(M)(Ft)

TOTALHEAD

(M3/H)

(GPM)FLOW

kW

AM-8619-3-50 8x10x20L HSC3 & HSC-S Series 1485

P-3820 6

513mm 305mm

18.00mm 477cm2

Minimum recommended flow is 40% B.E.P.

513mm A513mm A487mm B487mm B462mm C462mm C436mm D436mm D411mm E411mm E386mm F386mm F360mm G360mm G335mm H335mm H305mm I305mm I

A A B B C C D D E E F F G G H H I I

84848484

8383

8383

8282

8282

7979

7979

7676

7676

7171

7171

6565

6565

5858

1.21.28.88.8

2.12.17.97.9

4.94.95.25.2

NPSH REQ’D (METERS)NPSH REQ’D (METERS)SUCTION LIFT (METERS)SUCTION LIFT (METERS)

Bell & Gossett

Bell & Gossett

Page 17: Series HSC & HSC-S - Xylem Inc....Series HSC3 & HSC-S Horizontal Split Case Base Mounted – Double Suction 50 Cycle Performance Curves Part of Equipment Selection Programs 2 TABLE

1450 RPM PUMP CURVES

17

BX-560G

AREAINLET

DIA.MIN.

VANESNO. OF

IMPELLER DATARPMSPEED

SPHEREMAX.

DIA.MAX.

NO.IMP.

PUMPCURVE

0 100 200 300 400 500 600 7000

10

20

30

40

50

0

5

10

15

20

25

30

35

0 500 1000 1500 2000 2500 3000

0

25

50

75

100

(M)(Ft)

TOTALHEAD

(M3/H)

(GPM)FLOW

kW

AM-7495-5-50 1480

08-1629-48 6

325mm 236mm

39.12mm 557cm2

Minimum recommended flow is 40% B.E.P.

325mm A325mm A307mm B307mm B289mm C289mm C271mm D271mm D254mm E254mm E236mm F236mm F

A A

B B

C C D D

E E F F

81818181

7979

7979

7676727268686464585852524545

2.62.67.57.5

4.74.75.45.4

NPSH REQ’D (METERS)NPSH REQ’D (METERS)SUCTION LIFT (METERS)SUCTION LIFT (METERS)

10x10x12 HSC3 & HSC-S Series

AREAINLET

DIA.MIN.

VANESNO. OF

IMPELLER DATARPMSPEED

SPHEREMAX.

DIA.MAX.

NO.IMP.

PUMPCURVE

0 100 200 300 400 500 600 700 800 900 1000 11000

25

50

75

100

0

5

10

15

20

25

30

35

0 500 1000 1500 2000 2500 3000 3500 4000 4500

0

25

50

75

100

125

(M)(Ft)

TOTALHEAD

kW

AM-7496-6-50 10x12x12M HSC3 & HSC-S Series 1480

WT-20646-3 6

325mm 221mm

28.45mm 498cm2

Minimum recommended flow is 40% B.E.P.

325mm A325mm A309mm B309mm B294mm C294mm C279mm D279mm D264mm E264mm E248mm F248mm F

220mm G220mm G

A A B B

C C D D E E F F

G G

8585

8383

8383

8080

8080

7676

7676

7171656557574848

4.64.65.55.5

5.85.84.34.3

7.37.32.82.8

9.19.11.01.0

NPSH REQ’D (METERS)NPSH REQ’D (METERS)SUCTION LIFT (METERS)SUCTION LIFT (METERS)

(M3/H)

(GPM)FLOW

Bell & Gossett

Bell & Gossett

Page 18: Series HSC & HSC-S - Xylem Inc....Series HSC3 & HSC-S Horizontal Split Case Base Mounted – Double Suction 50 Cycle Performance Curves Part of Equipment Selection Programs 2 TABLE

1450 RPM PUMP CURVES

18

BX-560G

AREAINLET

DIA.MIN.

VANESNO. OF

IMPELLER DATARPMSPEED

SPHEREMAX.

DIA.MAX.

NO.IMP.

PUMPCURVE

0 200 400 600 800 1000 1200 14000

50

100

150

0

5

10

15

20

25

30

35

40

0 1000 2000 3000 4000 5000 6000

0

25

50

75

100

125

(M)(Ft)

TOTALHEAD

(M3/H)

(GPM)FLOW

kWAM-8705-2-50 10x12x12XL HSC3 & HSC-S Series 1480

P-4221 6

343mm 218mm

40.64mm 563cm2

Minimum recommended flow is 40% B.E.P.

342mm A342mm A

325mm B325mm B

307mm C307mm C

289mm D289mm D

271mm E271mm E

254mm F254mm F236mm G236mm G218mm H218mm H

A A B B

C C D D E E F F G G H H

8787

8787

8585

8585

8282

8282

7878

7878

7373

7373

676760605252

2.62.67.47.4

3.93.96.26.2

5.25.24.84.8

7.37.32.82.8

8.38.31.81.8

9.49.40.60.6

NPSH REQ’D (METERS)NPSH REQ’D (METERS)SUCTION LIFT (METERS)SUCTION LIFT (METERS)

AREAINLET

DIA.MIN.

VANESNO. OF

IMPELLER DATARPMSPEED

SPHEREMAX.

DIA.MAX.

NO.IMP.

PUMPCURVE

0 100 200 300 400 500 600 700 800 900 1000 110025

50

75

100

125

5

10

15

20

25

30

35

40

45

50

0 500 1000 1500 2000 2500 3000 3500 4000 4500

25

50

75

100

125

150

(M)(Ft)

TOTALHEAD

kW

AM-8069-5-50 10x12x14 HSC3 & HSC-S Series 1480

P-3212-2 6

356mm 254mm

41.15mm 604cm2

Minimum recommended flow is 40% B.E.P.

355mm A355mm A

337mm B337mm B

320mm C320mm C

302mm D302mm D284mm E284mm E

269mm F269mm F254mm G254mm G

A A

B B C C

D D E E

F F G G

8686

8686

8383

8383

8080

8080

7676

7676

7171

7171

656557574747

2.82.87.37.3

4.24.25.95.9

5.65.64.54.5

NPSH REQ’D (METERS)NPSH REQ’D (METERS)SUCTION LIFT (METERS)SUCTION LIFT (METERS)

(M3/H)

(GPM)FLOW

Bell & Gossett

Bell & Gossett

Page 19: Series HSC & HSC-S - Xylem Inc....Series HSC3 & HSC-S Horizontal Split Case Base Mounted – Double Suction 50 Cycle Performance Curves Part of Equipment Selection Programs 2 TABLE

1450 RPM PUMP CURVES

19

BX-560G

AREAINLET

DIA.MIN.

VANESNO. OF

IMPELLER DATARPMSPEED

SPHEREMAX.

DIA.MAX.

NO.IMP.

PUMPCURVE

0 100 200 300 400 500 600 700 800 900 10000

25

50

75

100

0

10

20

30

40

50

60

70

0 500 1000 1500 2000 2500 3000 3500 4000 4500

0

50

100

150

200

(M)(Ft)

TOTALHEAD

(M3/H)

(GPM)FLOW

kW

AM-7854-6-50 10x12x17 HSC3 & HSC-S Series 1485

08-1361 7

445mm 254mm

34.54mm 557cm2

Minimum recommended flow is 40% B.E.P.

444mm A444mm A419mm B419mm B393mm C393mm C368mm D368mm D342mm E342mm E317mm F317mm F292mm G292mm G

254mm H254mm H

A A B B

C C D D

E E F F

G G H H

8585

84848484

8282

8282

7878

7878

7474

7474

6868

6868

6262

6262

5454

5454

3.63.66.56.5

4.74.75.45.4

5.55.54.64.6

NPSH REQ’D (METERS)NPSH REQ’D (METERS)SUCTION LIFT (METERS)SUCTION LIFT (METERS)

Bell & Gossett

Page 20: Series HSC & HSC-S - Xylem Inc....Series HSC3 & HSC-S Horizontal Split Case Base Mounted – Double Suction 50 Cycle Performance Curves Part of Equipment Selection Programs 2 TABLE

Xylem Inc. 8200 N. Austin Avenue Morton Grove, Illinois 60053 Phone: (847) 966-3700 Fax: (847) 965-8379www.bellgossett.com

Bell & Gossett is a trademark of Xylem Inc. or one of its subsidiaries. © 2013 Xylem Inc. BX-560G January 2003

1) The tissue in plants that brings water upward from the roots;2) a leading global water technology company.

We’re 12,700 people unified in a common purpose: creating innovative solutionsto meet our world’s water needs. Developing new technologies that will improvethe way water is used, conserved, and re-used in the future is central to our work.We move, treat, analyze, and return water to the environment, and we help peopleuse water efficiently, in their homes, buildings, factories and farms. In more than150 countries, we have strong, long-standing relationships with customers whoknow us for our powerful combination of leading product brands and applicationsexpertise, backed by a legacy of innovation.

For more information on how Xylem can help you, go to www.xyleminc.com

Xylem