1kW to 16kW Central System GLX Series

Series - Home • IEP

  • Upload
    others

  • View
    2

  • Download
    0

Embed Size (px)

Citation preview

1kW to 16kW Central System

GLXSeries

Size Input Current@120V

OutputCurrent@120V

Input Current@277

Output Current

@277

Output Watts

Battery (DC)Voltage

BatteryCurrent

1kW 16 8 7 4 1000 192 6

1.5kW 21 13 9 5 1500 192 9

2kW 27 17 12 7 2000 192 12

3kW 37 25 16 11 3000 192 18

4kW 48 33 21 14 4000 192 24

5kW 64 42 28 18 5000 192 30

6kW 80 50 35 22 6000 192 36

7kW 91 58 39 25 7000 192 41

8kW 107 67 46 29 8000 192 47

10kW 134 83 56 36 10000 192 59

12kW 160 100 69 43 12000 192 71

14kW 182 117 79 51 14000 192 83

15kW 198 125 88 54 15000 192 89

16kW 214 133 95 58 16000 192 95

* Consult factory for other options.** Input currents are shown at high charge with full load rating per UL.

Normal and running currents are considerably less.

1

APPLICATIONS

• Airports• Apartments/Condominium

Complexes• Assisted Living Centers• Banks, Financials• Casinos• City, County, State, Federal

Buildings• Grocery Stores• Hospitals• Hotels• Industrial • Medical Offices• Military Complexes

• Movie Theaters• Office Buildings• Parking Garages• Prisons• Race Tracks• Train, Subway, Bus Stations• Religious Facilities• Restaurants• Department Stores• Schools, Colleges• Shopping malls• Sport facilities• Superstores• Tunnel and Toll Bridges

RATINGS TABLE

GLX Series Sine Wave

2

Dimensions for A: 1kW to 6kW

30”W x 72”H x 30”D

Dimensions for B:7kW and above

60”W x 72”H x 30”D

72”

30”60”

72”

30”30”

System Overview:The GLX Series Inverter is a central emergency light-ing system designed to operate all emergency loads. In the event of a power abnormality event, the GLX will provide emergency power to its connected loads for a run-time of no less than 90 minutes. The GLX is a system designed to provide superior dependability and security to any commercial, institutional or in-dustrial environment in a minimal footprint.

The line voltage output allows the remote fixtures to be located up to 2000 feet from the unit.

Power Factor: .9 leading to .9 lagging

GLX series inverter is designed to occupy a minimum footprint. Capable of supplying power to a nominal load of up to 6000 watts in a 30x30 footprint, the GLX central inverter system can be installed in any electrical room and centralizes all emergency lighting testing to one central location and streamlines any eventual maintenance and required record-keeping.

The GLX series is a compact, modular emergen-cy lighting inverter. Typical applications include all types of LED, fluorescent, incandescent, HID quartz re-strike and low voltage lighting. The modular de-sign and low MTTR (mean-time-to-repair) ensure easy maintenance. The GLX is well suited for stair-well, hallway, and outdoor emergency egress lighting, large size office buildings, schools and warehouses.

GLX Series inverter employs premium (*VRLA) bat-teries, designed with an expected service life of 10 years per battery manufacturer guidelines.

*VRLA Batteries are maintenance free. Periodic checks, coupled with standard record keeping and maintenance of the inverter would ensure the longev-ity of the battery module.

3

Theory of Operation:The GLX is designed to power the emergency egress lighting at full brightness for 90 minutes. The system is installed between the lighting distribution panel and the emergency circuit (s) and ahead of any local switches. Upon failure of the normal power source to the connected lights, the GLX will continue to power the emergency fixtures connected to it for a mini-mum of 90 minutes utilizing standard building lighting components. When the normal power is restored the GLX will automatically switch the lighting fixtures back to the normal source and recharge the batteries so that they are ready for the next power outage. The system may also be configured for normally off or for switched load capability as an option.

Applications: The GLX Series Inverter will operate incandescent, fluorescent, HID and LED lamps with power factor greater than .9.*Self ballasted compact fluorescent and replacement LED screw in lamps may be used.

Operating Parameters: Run Time: minimum 90 minutesHousing: Heavy duty code gauge steel construction finished in powder coat paint.

Environment:Operating temperature: 32F (0C) – 104F (40C)Altitude: 10,000 feet above sea level without deratingStorage temperature: -20 to 60 degrees C. Note – batteries will require frequent recharging if stored above 35 degrees C.

GLX design will provide full rated watts output from .9 leading to .9 lagging power factor. Loads outside of this power factor will reduce the total output of the unit depending on the va at that power factor.

GLX Series Sine Wave

Order Information

Note: 20 Amp output breakers standard unless otherwise ordered.

*Consult factory for other configuration/options

4

GLX

GLXGLX SeriesPure Sine

WaveLighting Inverter

OUTPUT BREAKERSExampleA 20 06

Warranty1-Year full warranty on

system electronics. Battery warranty 1-year with 9-years prorata. Maintenance

contracts available.

InputVoltage

120V208V277V480V

QTYMaximum 12pole positions

N - normally onO - normally off

S - switched(Distribution Breakers)

10, 16, 20, 25,32, 35, 40, 50, 63

POLEA-1-Pole

OCOutputVoltage120V208V277V

120/277V480V

RUNTIME(Other than 90 Minutes)

R30 - 30 MinutesR120 - 120 Minutes

OPTIONSF- Fast ChargeI - Inverter on Dry, Form C ContactS - Summary Dry, Form C ContactsT - Output Trip (super-vised) AlarmZ - Seismic Mounting

Capacity1kW2kW3kW4kW5kW6kW8kW10kW12kW16kW*

700 120 120 OPTIONS

A: PO Box 20302 Lehigh Valley PA 18002 | V: (610) 628 1488 | W: www.IEPSystems.com | E: [email protected]

5

Branch Breakers

NeutralBlock

Main Breaker

Battery Breaker

Main CircuitBoard

CoolingFan

Ground

Transformers

GLX Series Sine Wave

OVERVIEW:

6

Black powder coated paint

Display Panel

Call Today: 610.628.1488

Operating Parameters:Run Time: minimum 90 minutesInverter efficiency: >90%Housing: Heavy duty steel construction finished in powder coat paint.

Environment:Operating temperature: 32F (0C) – 104F (40C)Altitude: 10,000 feet above sea level without deratingStorage temperature: -20 to 70 degrees C. Note: batteries will require frequent recharging if stored above 35 degrees C.

*We recommend only Energy Star.

GLX design will provide full rated watts output from .9 leading to .9 lagging power factor. Loads outside of this power factor will reduce the total output of the unit depending on the va at that power factor.

Options:Suffix NOR - Normally off relay 1 required per every 20 amps of load (coil voltage matches input voltage of unit).Suffix ITP – Input breaker trip alarmSuffix OTP – Output breaker trip alarm, 1 per output breakerSuffix BTP – Battery breaker trip alarmSuffix OCB_ Additional output circuit breakers (note 20 amp output breakers are standard unless other-wise specified.Suffix R30 - Battery capacity of 30 minutes for when the system is used with a permanently installed emer-gency generator.Suffix R120 – Battery capacity of 120 minutes ( may require additional enclosures depending on the rating of the unit).Suffix RS232 -Suffix 208 or 240/480 or multiple voltage outputs – may require additional cabinets.

7

Standard features: • Footprint 30W” by 72H” for all models. • Free standing cabinet designed for floor mount. • 16 gauge cold-rolled steel construction finished in powder coat paint. • 6th generation IGBT technology for high effi ciency, low loss power inversion, SCR based rectifier, solid-state transfer switch, PWM, low THD to provide a system with high reliability and high efficiency. • MTTR of less than 30 minutes for any one component. • ETL listed to UL 924, meets or exceeds the requirements of OSHA, NEC, NFPA and other codes • OCPD (over-current protective devices) standard on input, battery and output. Additional output breakers are optional. • Standard cabinet designed for ease of installation, wiring and maintenance. • Front mounted meter panel for intuitive system status. • Basic alarms for overload, overload shutdown, high temperature, near low battery and low battery shutdown. • 92% efficiency on standby.

Specifications:Input:Voltage: 120, 208, 240, 277 or 480 VAC 2 wires plus ground +/- 15%Frequency: 60 Hz +/- 3 HzProtection: Circuit Breaker

Output: Voltage: 120, 208, 240, 277, or 480 VAC 2 wire plus groundFrequency: 60 Hz +/- .5 HzTHD: > 3% Linear loadRegulation: +/- 3% for 50% load changeInverter overload: 110% for 5 minutesProtection: Output Circuit Breaker

Battery:Type: Premium 10 year design life Valve Regulated Lead Acid (VRLA)Voltage: 192VDC nominal.Protection: DC Overcurrent Protective Device (OCPD) inside main electronic section.

GLX Series Sine Wave

Power Rating:Capacity: 1000W – 16kW single phase output with latest PWM technology to provide the most advanced performance and reliability. Input: 120V, 208V, 240V, 277V or 480V input 60Hz* Output: 120V, 208V, 277/4800V or 120/277 VAC true on-line designEfficiency:>92% efficient at 100% linear load

Batteries:Sealed, maintenance-free, lead calcium (AGM) batter-ies with10 year prorated warranty. The GLX employs Smart Battery Monitoring System which is tempera-ture compensated and maintains maximum run-time and battery life.

Electronics:Microprocessor controlled; recharge and over charge protection standard

Lamps and Loads:Emergency power provides FULL LIGHT OUTPUT from all lamps and fixtures for the entire run-time. GLX Series Inverter operates fluorescent, CFL, incan-descent, quartz, LED, HID and other approved lamp types and loads.

Codes:Listed to UL 924, NFPA 101, NFPA 70 NEC, and OSHA

Cabinet:Space saving small footprint Free Standing Indoor NEMA 1 enclosure with modular design enables flexi-ble installation.

8

Protection:Provides overload, surge and undercurrent protec-tion. Surge protection against load surges as defined in ANSI/IEEE C62.45 category A and B.

Diagnostics and Maintenance:GLX Series On-board Monitoring System provides complete self checking capabilities and LED Indicator light Monitor. Informative advanced Metering Display and Alarms keep you in control of your emergency lighting environment 24/7. Automatically performs checking ensuring a safely lighted environment prior to an emergency Single point of testing instead of hundreds with battery packs.

Installation:Modular design and small footprint allow easy instal-lation in electrical closet or other convenient loca-tions. Extended warranty available.

Warranty:1-Year full warranty on system electronics. Battery warranty 1-year with 9-years prorata. Maintenance contracts available.

IEP Systems A PO Box 20302 Lehigh Valley PA 18002 P tel.:(610) 628 1488 W website: www.iepsys.com E e-mail: [email protected]

CONTACT US

GLX Series Sine Wave