Upload
others
View
0
Download
0
Embed Size (px)
Citation preview
Work Session
Agenda Item # 1
Meeting Date September 21, 2015
Prepared By Erkin Ozberk, Senior Planner
Approved By Suzanne R. Ludlow City Manager
Discussion Item Discussion of Site Plan Application for N.E. Quadrant of New Hampshire Avenue and Holton Lane (Taco Bell)
Background The Memorandum of Understanding between the City of Takoma Park and the Montgomery County Planning Board establishes a coordinated review process for subdivision and site plan applications in Takoma Park. City Council communicates with the Planning Board via resolution. Options include:
1. No Resolution 2. Resolution to Approve 3. Resolution to Approve with Conditions 4. Resolution to Disapprove
The Council is asked to consider the site plan application for the Taco Bell development on New Hampshire Avenue at Holton Lane. Site plan review dictates landscaping, parking, and building specifics, which are being considered at this time. This is the first of two Council work sessions that have been scheduled. The site plan is tentatively scheduled to be reviewed by the Planning Board in December 2015. Status of the site plan’s review and downloads of plans and reports can be found on the Montgomery County Development Activity Information Center (DAIC) website: http://mcatlas.org/Development_Info/default.aspx?apno=820150150. Project Description The applicant, MUY Brands, LLC (Taco Bell) submitted a site plan application to construct a single-story commercial building on a pad site at the northeast quadrant of the intersection of New Hampshire Avenue and Holton Lane. The site is known as Lot 56 in the Gude and Abraham’s Subdivision with a net lot area of 24,591 square feet (0.56 acres), owned by JBG/Takoma Park Retail Center, LLC. Presently, the site is improved with a paved surface parking lot with some landscaped areas. This proposal would allow for the development of a single-story building with a 2,063 sq. ft. footprint to be used as a Taco Bell restaurant that facilitates a drive thru aisle, and landscaping around the building on both the New Hampshire Avenue and Holton Lane frontages. Zoning Designation The property is zoned CRT-2.5, a mixed use zoning designation with maximum Floor Area Ratio (FAR) of 2.5.
Project Review In November 2014, land use attorneys from Lerch, Early, & Brewer, representing Taco Bell, contacted HCD staff to discuss the project and the City’s involvement in Montgomery County’s development review process. At the time, staff recommended the Takoma/Langley Crossroads Sector Plan (and associated Design Guidelines) and the Holton Lane Area Improvement Vision as key policy documents to consider when developing the Site Plan application. A pre-submission meeting for the Site Plan application was held on April 29, 2015 at the Takoma Park Community Center. The Stormwater Management Concept was reviewed by the City Engineer and approved on May 12, 2015. Taco Bell representatives will be present at the September 21, 2015 work session to provide additional background information and answer any questions the Council may have regarding the site plan. A second worksession is scheduled for October 5, 2015 at which time a draft resolution will be presented for Council consideration. The resolution will be finalized and adopted by the Council on October 12, 2015.
Policy Redevelop and revitalize New Hampshire Avenue
Fiscal Impact
None
Attachments • Taco Bell Site Plan (Sheet C-4), Landscape Plan (Sheet LS-1) and Elevations (Sheets A4 and A4.1)
• Statement of Justification provided by Lerch, Early, Brewer, included in the Site Plan application
Recommendation Discuss proposed Site Plan
Special Consideration
Article 28 of the Maryland State Code requires that a two-thirds majority vote of both the Planning Board and the District Council of Montgomery County is required to take any action relating to zoning or land use planning within the City of Takoma Park that is contrary to a resolution of the Mayor and City Council.
AL
BLF
06/25/15
AS SHOWN
SS0
C-4OF 5
SITE PLAN
DEVELOPMENT SEQUENCE:
DEVELOPMENT IS PLANNED TO TAKE PLACE IN ONE PHASE
(DEMOLITION, BUILDING, AND SITE WORK)
NOTE:
SEE SHEET C-5 FOR SITE DETAILS
PROPOSED NOTE
CURB AND GUTTER
SPILL CURB TRANSITION CURB
DEPRESSED CURB AND GUTTER
TYPICAL NOTE TEXT
NEIGHBORING
PROPERTY LINE /
INTERIOR PARCEL LINE
STANDARD DRAWING LEGENDFOR ENTIRE PLAN SET
(NOT TO SCALE)
ONSITE PROPERTY
LINE / R.O.W. LINE
EASEMENT
LINE
SETBACK
LINE
CONCRETE CURB &
GUTTER
UTILITY POLE
WITH LIGHT
POLE
LIGHT
SAN
#
STM
#
SANITARY
LABEL
STORM
LABEL
SANITARY SEWER
LATERAL
UNDERGROUND
WATER LINE
UNDERGROUND
ELECTRIC LINE
UNDERGROUND
GAS LINE
OVERHEAD
WIRE
UNDERGROUND
TELEPHONE LINE
UNDERGROUND
CABLE LINE
STORM
SEWER
SANITARY
SEWER MAIN
HYDRANT
SANITARY
MANHOLE
STORM
MANHOLE
WATER
METER
WATER
VALVE
GAS
VALVE
GAS
METER
TYPICAL END
SECTION
HEADWALL OR
ENDWALL
YARD
INLET
CURB
INLET
CLEAN
OUT
ELECTRIC
MANHOLE
TELEPHONE
MANHOLE
ELECTRIC
BOX
ELECTRIC
PEDESTAL
MONITORING
WELL
TEST
PIT
S
COPYRIGHT 2003DELORME STREET ATLAS 2004 PLUS USA
SCALE: 1"=2000'
CONSTRUCTIONNOT APPROVED FOR
REVISIONS
REV DATE COMMENT BY
LOCATION OF SITE
FOR
PROJECT No.:
DRAWN BY:
CHECKED BY:
DATE:
SCALE:
CAD I.D.:
SHEET NUMBER:
SHEET TITLE:
PROJECT:
THE FOLLOWING STATES REQUIRE NOTIFICATION BYEXCAVATORS, DESIGNERS, OR ANY PERSON PREPARING TO
DISTURB THE EARTH'S SURFACE ANYWHERE IN THE STATE.IN VIRGINIA, MARYLAND, THE DISTRICT OF COLUMBIA,
NORTH CAROLINA AND DELAWARE CALL - 811
(WV 1-800-245-4848) (PA 1-800-242-1776) (DC 1-800-257-7777)(VA 1-800-552-7001) (MD 1-800-257-7777) (DE 1-800-282-8555)
MB14200601
MUYTACO BELL
NEW HAMPSHIRE AVE
AND HOLTON AVE
TAKOMA PARK, MD 20912
MONTGOMERY COUNTY
16701 MELFORD BLVD , SUITE 310
BOWIE, MARYLAND 20715
Phone: (301) 809-4500
Fax: (301) 809-4501
SU
ST
AIN
ABLE D
ESIG
N
LA
ND
SC
APE A
RC
HIT
EC
TU
RE
SIT
E C
IVIL
AN
D C
ON
SU
LT
ING
EN
GIN
EER
ING
LA
ND
SU
RV
EY
ING
PR
OG
RA
M M
AN
AG
EM
EN
T
PER
MIT
TIN
G S
ER
VIC
ES
TR
AN
SPO
RT
AT
ION
SER
VIC
ES
BO
ST
ON
, M
A
UP
ST
AT
E N
EW
YO
RK
NE
W Y
OR
K M
ET
RO
LE
HIG
H V
ALLE
Y, P
A
SO
UT
HE
AS
TE
RN
, P
A
PH
ILA
DE
LP
HIA
/SO
UT
HE
RN
NJ
SO
UT
HE
RN
MA
RY
LA
ND
BA
LT
IMO
RE
, M
D
WA
SH
ING
TO
N, D
C
CE
NT
RA
L V
IRG
INIA
CH
AR
LO
TT
E, N
C
RA
LE
IGH
, N
C
NO
RT
HE
RN
VIR
GIN
IA
WA
RR
EN
, N
J
TM
GENERAL NOTE:
IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO REVIEW ALL OF THE DRAWINGS AND SPECIFICATIONS ASSOCIATED WITH THIS PROJECT
WORK SCOPE PRIOR TO THE INITIATION OF CONSTRUCTION. SHOULD THE CONTRACTOR FIND A CONFLICT WITH THE DOCUMENTS RELATIVE TO
THE SPECIFICATIONS OR APPLICABLE CODES, IT IS THE CONTRACTOR'S RESPONSIBILITY TO NOTIFY THE PROJECT ENGINEER OF RECORD IN
WRITING PRIOR TO THE START OF CONSTRUCTION. FAILURE BY THE CONTRACTOR TO NOTIFY THE PROJECT ENGINEER SHALL CONSTITUTE
ACCEPTANCE OF FULL RESPONSIBILITY BY THE CONTRACTOR TO COMPLETE THE SCOPE OF THE WORK AS DEFINED BY THE DRAWINGS AND IN
FULL CONFORMANCE WITH LOCAL REGULATIONS AND CODES.
PROFESSIONAL CERTIFICATION
MARYLAND LICENSE No. 39999
I, MATTHEW K. JONES, HEREBY CERTIFY THAT THESE
DOCUMENTS WERE PREPARED OR APPROVED BY ME, AND
THAT I AM A DULY LICENSED PROFESSIONAL ENGINEER
UNDER THE LAWS OF THE STATE OF MARYLAND,
LICENSE NO. 39999, EXPIRATION DATE: 3/15/2017
1"= 20'
0 205 10 20
LEGEND
PUBLIC OPEN SPACE
PROJECT DATA TABLE: CRT-2.5 ZONE (C-2.0, R-1.5, H-100 )
ZONING ORDINANCE
DEVELOPMENT STANDARDS
PROPOSED FOR
SITE PLAN
APPROVAL
B. GROSS TRACT AREA NONE 0.56 AC
C. MAXIMUM BUILDING HEIGHT 100' 23'
D. FLOOR AREA RATIO (FAR) (BUILDING COVERAGE TO GROSS TRACT AREA)
C=2.0 (48,787 SF)
R=1.5 (36,590 SF)
2.5 MAX (60,984 SF)
0.1 FAR OR
2,063 SF GFA
E. PUBLIC OPEN SPACE
TOTAL PUBLIC OPEN SPACE10 % NET TRACT AREA
2,459 SF2,500 SF
H. MIN. BUILDING SETBACKS
FRONT(NEW HAMPSHIRE AVE.) 0' 0'
REAR 0' 0'
NORTH SIDE 0' 0'
SOUTH SIDE (HOLTON LANE) 0' 0'
I. MAXIMUM SETBACK - BUILD TO AREA1
FRONT STREET
70% OF THE BUILDING FACADE
MUST BE WITHIN 30' OF NEW
HAMPSHIRE AVE WITH EXISTING
10 FOOT PUE.1
70% OF THE
BUILDING
FACADE IS
WITHIN 27' OF
NEW HAMPSHIRE
AVE.
SIDE STREET
35% OF THE BUILDING FACADE
MUST BE WITHIN OF 20' OF
HOLTON LANE.
35% OF THE
BUILDING
FACADE IS
WITHIN 15.5' OF
HOLTON LANE.
1 THE BUILD TO AREA MAXIMUM SETBACK MAY BE INCREASED BY THE MINIMUM SETBACK NECESSARY TO AVOID A PLATTED PUBLIC
UTILITY EASMENT.
D
PARKING REQUIREMENTS (CRT-2.53,4)
BUILDING USE CATEGORY ZONING ORDINANCE DEVELOPMENT
STANDARDSPARKING REQUIRED PARKING PROPOSED
MNIMUM MAXIMUM MINIMUM MAXIMUM STANDARD SPACES 25 SPACES
TACO
BELL
RESTAURANT
(GENERAL) 4 SPACES/1,000 S.F.
OF PATRON USE
12 SPACES/1,000 S.F.
OF PATRON USE
4/1,000 X 875.3 PATRON S.F. = 3.5
= 4 SPACES
12/1,000 X 875.3 PATRON S.F. = 10.5
= 11 SPACESADA SPACES 2 SPACES (2 VAN ACCESSIBLE)
TOTAL SPACES 4 SPACES 11 SPACES 27 SPACES2
2 PARKING COMPLIES WITH THE MAXIMUM REQUIREMENT BECAUSE PARKING SPACES IN EXCESS OF MAXIMUM WILL NOT BE RESERVED FOR TACO BELL'S USE.
3 THE TACO BELL LOT IS PART OF AN INTEGRATED SHOPPING CENTER, FOR WHICH THERE IS SHARED PARKING. A MINIMUM OF 206 PARKING SPACES AND A MAXIMUM OF 355 PARKING SPACES ARE REQUIRED FOR THE
OVERALL SHOPPING CENTER. AFTER CONSTRUCTION OF THE TACO BELL, A TOTAL OF 269 PARKING SPACES WILL BE PROVIDED.
4CRT-2.5 ZONE IS ELIGIBLE TO BE CONSIDERED A REDUCED PARKING AREA. REQUIRED SPACES SHOWN REFLECT THIS REDUCTION.
SITE PLAN#820150150
TACO BELLTAKOMA PARK