SENSITIVE NOISE RECEPTOR REPORT

NOVEMBER 2020

Page 2: SENSITIVE NOISE RECEPTOR REPORT - INCOG

i

On November 5, 2020, an assessment was performed by the project team for sensitive noise receptors (SNRs) along the existing industrial lead track where improvements and construction will occur. Twenty-one (21) homes were observed to be in the closest proximity to the industrial lead track where improvements or new construction will occur. As shown on pages 1-3, SNRs 1 through 13 are scattered on the north and south side along the existing industrial lead track between S 4220 Rd and S 4210 Rd. The approximate distance of these SNRs from the railroad ROW are as follows: 187′, 347′, 386′, 352′, 586′, 340′, 512′, 162′, 425′, 320′, 518′, 447′ and 333′, respectively. These SNRs should experience a temporary increase in daytime noise levels resulting from improvements to the lead track. There are eight (8) SNRs in the area where Track C and Track D will be constructed and track improvements will occur. As shown on pages 3-4, SNRs 14 through 21 are all located on the south side of the existing industrial lead between S 4210 Rd and S 4200 Rd and/or along E 4210 Rd. The approximate distance of the SNRs from the railroad ROW are as follows: 135′, 571′, 135′, 142′, 154′, 130′, 130′ and 444′, respectively. SNRs in this location should experience a temporary increase in daytime noise levels resulting from new track construction and track improvements.

A General Noise and/or Vibration Assessment was conducted to determine the expected impact to the identified SNRs described above. The three sources listed from the source reference list that pertain to the Project are Freight Locomotive, Freight Cars, and Crossover (switches). According to the data that was inputted into the Noise Model Based spreadsheet on pages 14-17, the day-night (Ldn) noise levels are 39, 39, and 6 for each noise source, respectively. All sources have a Ldn (dB) level of 42. According to the FTA guidance manual, Table 81, this dB level is defined as “Occasional Events” that could impact sensitive receptors. (The maximum dB level allowable for Category 2 sensitive receptors is 78.)

Page 3: SENSITIVE NOISE RECEPTOR REPORT - INCOG

N S

1

2

187'

347'

1

Page 4: SENSITIVE NOISE RECEPTOR REPORT - INCOG

N S

3

4

5

6

7

89

10

11

386'

352'586'

340'

512'

162'

320'

425'

518'

2

Page 5: SENSITIVE NOISE RECEPTOR REPORT - INCOG

N S

12

13

14

15

16

17

18

19

20

333'

447'

135'

571'

135'

142'

154'

130'

130'

3

Page 6: SENSITIVE NOISE RECEPTOR REPORT - INCOG

21

444'

4

Page 7: SENSITIVE NOISE RECEPTOR REPORT - INCOG

PROJECT CONSTRUCTION ELEMENTS LOCATIONS

5

Page 8: SENSITIVE NOISE RECEPTOR REPORT - INCOG

Sensitive Noise Receptor Area Noted On Page 1, South Side of Track At S 4220 Rd Crossing

6

Page 9: SENSITIVE NOISE RECEPTOR REPORT - INCOG

Sensitive Noise Receptors Noted On Page 1 and 2, South Side of Track 7

Page 10: SENSITIVE NOISE RECEPTOR REPORT - INCOG

Sensitive Noise Receptors On South Side of Track, As Noted on Page 2 8

Page 11: SENSITIVE NOISE RECEPTOR REPORT - INCOG

Sensitive Noise Receptors On North Side of Track, As Noted On Page 2 9

Page 12: SENSITIVE NOISE RECEPTOR REPORT - INCOG

Sensitive Noise Receptor at S 4210 Crossing, North Side of Track, As Noted On Page 3 10

Page 13: SENSITIVE NOISE RECEPTOR REPORT - INCOG

Sensitive Noise Receptors At S 4210 Crossing, South Side of Track, As Noted On Page 3 11

Page 14: SENSITIVE NOISE RECEPTOR REPORT - INCOG

Sensitive Noise Receptors, South Side of Track, As Noted On Page 3 12

Page 15: SENSITIVE NOISE RECEPTOR REPORT - INCOG

Sensitive Noise Receptors, South Side of Track, As Noted On Page 3 13

Page 16: SENSITIVE NOISE RECEPTOR REPORT - INCOG

Sensitive Noise Receptor At S 4200 Rd Crossing, South Side of Track, As Noted On Page 4

14

Page 17: SENSITIVE NOISE RECEPTOR REPORT - INCOG

Noise Model

Noise Model Based on Federal Transit Adminstration General Transit Noise Assessment

Developed for Chicago Create Project

Copyright 2006, HMMH Inc.

Case:

Noise Source

All Sources

Source 1 Source 2Source 3Source 4Source 5Source 6Source 7Source 8

Enter noise receiver land use category below.

2

Enter data for up to 8 noise sources below - see reference list for source numbers.

NOISE SOURCE PARAMETERS

Parameter

Source Num. Freight Locomotive 9 Freight Cars 10 Crossover 13Distance (source to receiver) distance (ft) 515 distance (ft) 515 distance (ft) 1800Daytime Hours speed (mph) 5 speed (mph) 5 trains/hour 0.25 (7 AM - 10 PM) trains/hour 0.25 trains/hour 0.25 duration of one train (sec) 1800

locos/train 2 length of cars (ft) / train 5000 Nighttime Hours speed (mph) 0 speed (mph) 0 trains/hour 0 (10 PM - 7 AM) trains/hour 0 trains/hour 0 duration of one train (sec) 0

locos/train 0 length of cars (ft) / train 0 Wheel Flats? 0.00% % of cars w/ wheel flats 0.00%Jointed Track? Y/N Y Y/N YEmbedded Track? Y/N N Y/N N Y/N NAerial Structure? Y/N N Y/N N Y/N NBarrier Present? Y/N Y Y/N Y Y/N YIntervening Rows of of Buildings number of rows 1 number of rows 1 number of rows 1

Source Number

Commuter Electric Locomotive 1Commuter Diesel Locomotive 2Commuter Rail Cars 3RRT/LRT 4AGT, Steel Wheel 5AGT, Rubber Tire 6Monorail 7Maglev 8Freight Locomotive 9Freight Cars 10Hopper Cars (empty) 11Hopper Cars (full) 12Crossover 13Automobiles 14City Buses 15Commuter Buses 16Rail Yard or Shop 17Layover Tracks 18Bus Storage Yard 19Bus Op. Facility 20Bus Transit Center 21Parking Garage 22Park & Ride Lot 23

Source 6Source 4

RESULTS

Source 1 Source 2 Source 3

62323

Leq - nighttime (dB)

LAND USE CATEGORY

Noise receiver land use category (1, 2 or 3)

Source 5

0 0

Leq - daytime (dB)

444041

0-5511

0 0

0

0

0

000

00

SOURCE REFERENCE LIST

Ldn (dB)

423939900

Page 1

15

Page 18: SENSITIVE NOISE RECEPTOR REPORT - INCOG

Noise Model

1 2 3 4

Term Sou 1 Sou 2 Sou 3 Sou 4 Sou 5 Sou 6 Sou 7 Sou 8

SELref 97.0 100.0 100.0 0.0 0.0 0.0 0.0 0.0 Num Desc Ref SEL Dist Term

C1 - Coef 10.0 20.0 10.0 0.0 0.0 0.0 0.0 0.0 0 0 0C1 - Denom 40.0 40.0 1.0 0.0 0.0 0.0 0.0 0.0 1 Commuter Electric Locomotive 90 15C1 - Day Num 20.00 20.00 0.25 0.00 0.00 0.00 0.00 0.00 2 Commuter Diesel Locomotive 92 15C1 - Night Num 20.00 20.00 0.01 0.00 0.00 0.00 0.00 0.00 3 Commuter Rail Cars 82 15C1 - Day -3.0 -6.0 -6.0 0.0 0.0 0.0 0.0 0.0 4 RRT/LRT 82 15C1 - Night -3.0 -6.0 -20.0 0.0 0.0 0.0 0.0 0.0 5 AGT, Steel Wheel 80 15C2 - Coef 10.0 10.0 10.0 0.0 0.0 0.0 0.0 0.0 6 AGT, Rubber Tire 78 15C2 - Denom 1.0 1.0 3600.0 0.0 0.0 0.0 0.0 0.0 7 Monorail 82 15C2 - Day Num 0.25 0.25 1800.00 0.00 0.00 0.00 0.00 0.00 8 Maglev 72 15C2 - Night Num 0.01 0.01 0.01 0.00 0.00 0.00 0.00 0.00 9 Freight Locomotive 97 15C2 - Day -6.0 -6.0 -3.0 0.0 0.0 0.0 0.0 0.0 10 Freight Cars 100 15C2 - Night -20.0 -20.0 -55.6 0.0 0.0 0.0 0.0 0.0 11 Hopper Cars (empty) 104 15C3 - Coef 10.0 10.0 0.0 0.0 0.0 0.0 0.0 0.0 12 Hopper Cars (full) 100 15

C3 - Denom 1.0 2000.0 0.0 0.0 0.0 0.0 0.0 0.0 13 Crossover 100 25 C3 - Day Num 2.00 5000.00 0.00 0.00 0.00 0.00 0.00 0.00 14 Automobiles 73 15 C3 - Night Num 1.00 40.00 0.00 0.00 0.00 0.00 0.00 0.00 15 City Buses 84 15 C3 - Day 3.0 4.0 0.0 0.0 0.0 0.0 0.0 0.0 16 Commuter Buses 88 15 C3 - Night 0.0 -17.0 0.0 0.0 0.0 0.0 0.0 0.0 17 Rail Yard or Shop 118 25 Leq50ft - Day 55.4 56.3 55.4 0.0 0.0 0.0 0.0 0.0 18 Layover Tracks 109 25

Leq50ft - Night 38.4 21.4 -11.2 0.0 0.0 0.0 0.0 0.0 19 Bus Storage Yard 111 25Ldn50ft 53.8 54.3 53.3 6.4 6.4 6.4 6.4 6.4 20 Bus Op. Facility 114 25Dist Coef 15.0 15.0 25.0 0.0 0.0 0.0 0.0 0.0 21 Bus Transit Center 101 25Adj. Dist -15.2 -15.2 -38.9 0.0 0.0 0.0 0.0 0.0 22 Parking Garage 92 25Adj. Wheel Flats 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 23 Park & Ride Lot 101 25Adj. Jointed 5 5 0 0 0 0 0 0Adj. Embed 0 0 0 0 0 0 0 0Adj. Aerial 0 0 0 0 0 0 0 0Adj. Shield -5 -5 -5 0 0 0 0 0 Category Ldn/Leq

Leq - Day 40.2 41.1 11.5 0.0 0.0 0.0 0.0 0.0 0Leq - Night 23.2 6.2 -55.1 0.0 0.0 0.0 0.0 0.0 1 LeqLdn 38.6 39.1 9.4 0.0 0.0 0.0 0.0 0.0 2 LdnNeed Land Use 0 3 LeqCalc Leq 0

CALCULATIONS REFERENCE DATA

Source 8

LAND USE DATA

Source 7Source 6

Page 2

16

Page 19: SENSITIVE NOISE RECEPTOR REPORT - INCOG

Noise Model

5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21

Term 1 Term 2 Term 3 Combine

Desc Denom Min Coef Desc Denom Min Coef Desc Denom Min Coef Jointed Embedded Aerial Barrier 1&2?

0 0 0 speed (mph) 50 20 10.0 trains/hour 1 0.01 10.0 locos/train 1 1 10 5.0 3.0 4.0 -5.0 0.0speed (mph) 50 20 -10.0 trains/hour 1 0.01 10.0 locos/train 1 1 10 5.0 3.0 4.0 -5.0 0.0speed (mph) 50 20 20.0 trains/hour 1 0.01 10.0 cars/train 1 1 10 5.0 3.0 4.0 -5.0 0.0speed (mph) 50 20 20.0 trains/hour 1 0.01 10.0 cars/train 1 1 10 5.0 3.0 4.0 -5.0 0.0speed (mph) 50 20 20.0 trains/hour 1 0.01 10.0 cars/train 1 1 10 -5.0 0.0speed (mph) 50 20 20.0 trains/hour 1 0.01 10.0 cars/train 1 1 10 -5.0 0.0speed (mph) 50 20 20.0 trains/hour 1 0.01 10.0 cars/train 1 1 10 -5.0 0.0speed (mph) 50 20 20.0 trains/hour 1 0.01 10.0 cars/train 1 1 10 4.0 -5.0 0.0speed (mph) 40 20 10.0 trains/hour 1 0.01 10.0 locos/train 1 1 10 5.0 3.0 4.0 -5.0 0.0speed (mph) 40 20 20.0 trains/hour 1 0.01 10.0length of cars (ft) / train2000 40 10 5.0 3.0 4.0 -5.0 0.0speed (mph) 40 20 20.0 trains/hour 1 0.01 10.0length of cars (ft) / train2000 40 10 5.0 3.0 4.0 -5.0 0.0speed (mph) 40 20 20.0 trains/hour 1 0.01 10.0length of cars (ft) / train2000 40 10 5.0 3.0 4.0 -5.0 0.0trains/hour 1 0.01 10.0duration of one train (sec)3600 0.01 10.0 3.0 4.0 -5.0 0.0

speed (mph) 50 30 28.1 vehicles/hour 1 0.01 10.0 -5.0 0.0speed (mph) 50 30 23.9 vehicles/hour 1 0.01 10.0 -5.0 0.0speed (mph) 50 30 14.6 vehicles/hour 1 0.01 10.0 -5.0 0.0trains/hour 20 0.01 10.0 -5.0 0.0trains/hour 1 0.01 10.0 -5.0 0.0buses/hour 100 0.01 10.0 -5.0 0.0buses/hour 200 0.01 10.0 buses serviced/hour 60 0.01 10.0 -5.0 1.0buses/hour 20 0.01 10.0 -5.0 0.0autos/hour 1000 0.01 10.0 -5.0 0.0autos/hour 2000 0.01 10.0 buses/hour 24 0.01 10.0 -5.0 1.0

REFERENCE DATA

Page 3