PSS® 3000 SeriesSelf contained breathing apparatus Instructions for Usei
1 For your safety1.1 General safety statements● Beforeusingthisproduct,carefullyreadtheInstructionsforUse.● Strictly follow the Instructions forUse.Theusermust fullyunderstandandstrictly
observe the instructions. Use the product only for the purposes specified in theIntendedUsesectionofthisdocument.
● Do not dispose of the Instructions for Use. Ensure that they are retained andappropriatelyusedbytheproductuser.
● Onlyfullytrainedandcompetentusersarepermittedtousethisproduct.● Complywithalllocalandnationalrulesandregulationsassociatedwiththisproduct.● Onlytrainedandcompetentpersonnelarepermittedtoinspect,repairandservicethe
product.DrägerrecommendsaDrägerservicecontractforallmaintenanceactivitiesandthatallrepairsarecarriedoutbyDräger.
● ProperlytrainedservicepersonnelmustinspectandservicethisproductasdetailedintheMaintenancesectionofthisdocument.
● UseonlygenuineDrägersparepartsandaccessories,ortheproperfunctioningoftheproductmaybeimpaired.
● Donotuseafaultyorincompleteproduct,anddonotmodifytheproduct.● NotifyDrägerintheeventofanycomponentfaultorfailure.● Allapprovedrespiratoryequipmentshallbeselected,fitted,used,andmaintainedin
accordancewithMSHA(MineSafetyandHealthAdministration),OSHA(OccupationalSafetyandHealthAdministration),andotherapplicableregulations.
● Donotuseanyformofchemicalmarkingorpaintontheequipment.● TheairsupplyshallmeettherequirementsforbreathingairaccordingtoCGAG–7.1,
GradeDorhigherquality.
1.2 DefinitionsofalerticonsAlerticonsareusedinthisdocumenttoprovideandhighlighttextthatrequiresagreaterawarenessbytheuser.Adefinitionofthemeaningofeachiconisasfollows:
!WARNING
Indicatesapotentiallyhazardoussituationwhich,ifnotavoided,couldresultindeathorseriousinjury.
!CAUTION
Indicatesapotentiallyhazardoussituationwhich,ifnotavoided,couldresultinphysicalinjuryordamagetotheproductorenvironment.Itmayalsobeusedtoalertagainstunsafepractices.
iiNOTICE
Indicatesadditionalinformationonhowtousetheproduct.
WRAH-1653
COMPRESSED AIRbar
050
100150200
250
300
DD
PSS®isaregisteredtrademarkofDräger
13106
3
2
6
53109
31103108
2587
12
3
4
5
7
6
D
100150
50
200250
300
0bar
COMPRESSED AIR
D
43379
1
3 Use
!WARNING
Only trained and competent personnel should prepare and use breathingapparatus.Ensurethatanyaccessories,ancillaryequipmentandotherprotectiveclothing itemsdonot interferewith theapparatusanddonotcreateasafetyhazard.
Theeffectiveworkingdurationof theapparatus isdependenton the initialair
supplyavailableandthebreathingrateofthewearer.Fillaircylinderstotheirfullratedpressurepriortouse,anddonotcommenceanyoperation(includingsupplied-air respirator (SAR)operations)usingacylinder that is less than90percentfull.
!CAUTION
Donotapplyexcessiveforceorusetoolstoopenorcloseacylindervalve,anddonotdroporthrowdownthebreathingapparatus.
Refer to the following additional information before preparing or using the breathingapparatus:● Thespecialinstructions(seeSection9).● TheNIOSHApprovalLabel3359026forapprovedconfigurations.
3.1 Preparation for use
iiNOTICE
The face of the pressure gaugemay be fitted with a thin flexible protectivecovering.Removethiscoveringbeforefirstuse.
1. Carryoutavisualinspectionofthebreathingapparatus(seeSection3.5.1).2. Fittheaircylinder(seeSection3.5.2).3. Pressthemalecouplingofthelungdemandregulatorhoseintothefemalecouplingof
themedium-pressurehoseuntilanaudibleclickisheard(donotconnecttheregulatortothefacemaskatthisstage).
4. Presstheresetbutton(Fig2,Item1)toswitchoffthepositivepressure.Pressandrotatethebypassbutton(Fig2,Item3)toaligntheredspotsandthenreleasethebuttontoswitchoffthebypass.
5. Carryoutafullfunctionaltestoftheapparatus(seeSection3.5.3).6. Alignandpushthelungdemandregulatorintofacemaskportuntilitlatchesinposition,
andchecktheattachmentbygentlyattemptingtopullthecouplingapart.
3.2 Putting on the breathing apparatus1. Fullyloosentheshoulderstrapsandwaistbeltandputonthebreathingapparatus.2. Checkthattheshoulderpadsarenottwistedandtaketheweightofthesystemonthe
shouldersbypullingtheshoulderstraps.Donotfullytightenatthisstage.3. Closethewaistbeltbuckleandpulltheendsofthewaistbeltuntilitfitssecurelyand
comfortably(Fig3).Tuckthebeltendsbehindthewaistpadorbelt.4. Pulltheshoulderstrapsuntilthebreathingapparatusrestssecurelyandcomfortablyon
thehips.Donotovertighten.Tuckthebeltendsbehindthewaistpadorbelt.5. Fullyloosentheheadstrapsofthefacemaskandplacetheneckstrapovertheback
oftheneck.6. Presstheresetbutton(Fig2,Item1)toswitchoffthepositivepressure.7. Openthecylindervalve(counterclockwise)slowly,butfully,topressurizethesystem.8. Putonthefacemaskandcheckfortightfit(seetheInstructionsforUsesuppliedwith
thefacemask).
3.3 During use
!WARNING
Fullyopenthecylindervalveandensureitremainsopenduringuse.
Usersshouldbeinasafeareabeforetheend-of-servicetime(EOST)whistlewarning commences. Evacuate to a safe area immediately if the warningcommencesduringanoperation.
Usingthebypassbutton(Fig2,Item3)willuseairfromthecylinderandrapidlyreducetheworkingdurationoftheapparatus.
● Regularlychecktheremainingcylinderpressureonthegauge.● Ifadditionalairisrequired,brieflypressandreleasethebypassbutton(Fig2,Item3)to
deliverasinglejetofairintothefacemask.
!WARNING
Theemergencyair flowproceduresbelowmaygreatly reduce theoperatingdurationoftheairsupply.Whenactivatedtheusermustimmediatelyevacuatetoasafearea.Thereasonforusingtheproceduremustbe investigatedandrepairedbeforereusingtheapparatus.
● Additionalairflowrequired(emergencyprocedureonlyusedintheunlikelyconditionofloworblockedairflow)–Pressandrotatethebypassbutton(Fig2,Item3)todeliverasustainedairsupply(85to130liters/minute)intothefacemask.
● Excessiveorlossofairflow(emergencyprocedureonlyusedintheunlikelyconditionofhighorlossofairflow)–Closethecylindervalvethenimmediatelybegintoslowlyreopenthevalve.Usethecylindervalveasaregulatingvalvetosettheairflowtomeettheuserrequirement.Thisprocedurecanbeusedwithscrew-typeandratchet-typecylindervalves.
3.4 After use
!WARNING
Donotremovethebreathingapparatusuntilinasafebreathingenvironment.
1. Loosen the facemaskstraps.As thesealbetween the facemaskand the face isbroken,presstheresetbutton(Fig2,Item1)toswitchoffthepositivepressure.Fullyremovethefacemaskandextendallofthestrapsoftheheadharness.
2. Closethecylindervalve.3. Pressthefrontbutton(Fig2,Item2)toventsystemandthenpresstheresetbutton
(Fig2,Item1)toswitchoffthepositivepressure.4. Releasethewaistbeltbuckle.5. Lifttheshoulderstrapbucklestoloosenthestraps.6. Removethebreathingapparatusandfacemask.7. Carryouttheafterusetasksinthemaintenancetable(seeSection5.1).8. Removetheaircylinderifrequired(seeSection3.5.2).9. Passthebreathingapparatustotheservicedepartmentwithdetailsofanyfaultsor
damagethatoccurredduringuse.
73111
1
23
3.5 Common user tasks3.5.1 Visual inspection
Avisualinspectionmustcheckthefullbreathingapparatusincludingallcomponentpartsandaccessories.Checkthattheequipment iscleanandundamaged,payingparticularattentiontopneumaticcomponents,hosesandconnectors.Typicalsignsofdamagethatmay affect the operation of the breathing apparatus include impact, abrasion, cutting,corrosion and discoloration. Report damage to service personnel and do not use theapparatusuntilfaultsarerectified.
3.5.2 Aircylinderfittingandremoving
!WARNING
High-pressureairreleasemaycauseinjurytotheuserorotherpersonnelnearthebreathingapparatus.Closethecylindervalveandfullyventthesystembeforeattemptingtodisconnectanaircylinder.
Impact damage to the cylinder valve or first-stage regulator connector mayprevent valve connection or cause an air leak. Handle the air cylinder andbreathingapparatuswithcare.
iiNOTICE
The following instructionsare foraCGA-type threadedcylindercoupling.Forothercylinderconnectortypes,refertotheInstructionsforUsesuppliedwiththeconnector.
Fitting the cylinder1. Checkthethreadsofthecylindervalveportandthefirst-stageregulator.Ensurethat
theO-ringseal(Fig4,Item1)intheregulatoriscleanandundamaged.2. Lay the apparatus horizontal, with the regulator uppermost, and fully extend the
cylinderstrap.3. Insertthecylinderthroughtheloopofthestrap,andalignthevalvewiththeregulator.4. Liftthecylinderandspaceframeintotheverticalposition(supportedontheendofthe
cylinderoppositethevalve).5. Tightenthehandwheeloftheregulator,usingonlythethumbandindexfinger,untila
definitemetal-to-metalcontactisfelt.Donotusetoolsorovertighten.6. Placetheunitbackintothehorizontalposition.7. Takeuptheslackinthecylinderstrap(Fig5).8. Pullthestrapoverthecylindertooperatethecamlock(Fig6).9. Securethestrapendusingthecylinderstrapretainer(Fig7).Releasethecamlockto
adjustthepositionofthecylinderstrapretainerifnecessary.
Removingthecylinder1. Close thecylindervalveandpress the frontbutton (Fig2, Item2) to fullyvent the
system.2. Laytheapparatushorizontal,withthecylinderuppermost.3. Liftthecylinderstrapretainer.4. Liftthestrapagainstthecamlocktoreleasethebuckletension,andthenloosenthe
strap.5. Disconnectthecylindervalvefromthefirst-stageregulator.6. Liftthecylinderawayfromtheregulatorandremovethecylinder.
3.5.3 Functional testing
!WARNING
Failureofthebreathingapparatustomeetanyofthestandardsorparametersdescribed in the functional tests indicates a system fault. Report the fault totrainedservicepersonnelorcontactDräger.Donotusethebreathingapparatusuntilthefaultconditionisrectified.
Assemblethebreathingapparatusasdescribedinthepreparationforuse(seeSection3.1)beforecommencinganyfunctionaltesting.
Leak test and whistle warning test1. Presstheresetbutton(Fig2,Item1)toswitchoffthepositivepressure.Pressand
rotatethebypassbutton(Fig2,Item3)toaligntheredspotsandthenreleasethebuttontoswitchoffthebypass.
2. Open the cylinder valve (counterclockwise) slowly, but fully, to pressurize system.Duringpressurizationamomentarysoundingofthewhistlewilloccur.
3. Fullyclosethecylindervalve.4. Afteroneminute,checkthecontentsgaugeandthenreopenthecylindervalve.The
gaugemustnotshowanincreaseinpressureofmorethan200psi.Ifthepressureincreaseismorethan200psi,investigateandrepairthefault(seeSection4),andthenrepeattheleaktest.
5. Fullyclosethecylindervalve.6. Covertheoutletportofthelungdemandregulatorwiththepalmofthehandandpress
thefrontbutton(Fig2,Item2)toswitchonthepositivepressure.7. Carefullyliftthepalmofthehandtoslowlyventthesystemuntilthewhistleactivates,
andobservethepressuredisplayedonthegauge.8. Thewhistlemustbegintosoundintherange: 2216psicylinder:600psito510psi 4500psicylinder:1215psito1035psi9. Continuetoventthesystemuntilfullyexhausted.10.Presstheresetbutton(Fig2,Item1)toswitchoffthepositivepressure.
2 Description2.1 ProductoverviewThe Dräger PSS® 3000 Series is a self contained breathing apparatus (SCBA) thatprovidesthewearerwithrespiratoryprotectionusinganopen-circuit,pressure-demand,compressed-airsystem.Theapparatuscanbeusedasaself-containedsystem,orwithanindependentairsupplyforsupplied-airrespirator(SAR)operations.Theseriesiscompatiblewithawiderangeofcompressed-aircylinders,facemasksandlungdemandregulators(e.g.FPS7000andPanoramaNovafacemasks,Drägerlungdemandregulators,andaluminumorcompositecylinders).
2.2 Feature descriptionThecarryingsystemusesalightweightpolymer-compositespaceframe(Fig1,Item3).Theshoulderstrapsandwaistbeltarefullyadjustableandusewebbingharnessstrapsandmouldedpaddingontheshoulderpadsandwaistpad.
Theapparatususes theDrägerhigh-performancefirst-stage regulator (6) that reducescylinderpressureandsuppliesbreathingair throughamedium-pressurehose (5)andcoupling(1)toanattachedlungdemandregulator.Theapparatusisfittedwithamechanicalpressuregauge(4)thatincorporatesanend-of-servicetime(EOST)whistlethatsoundstowarnthewearerthatthereislowcylinderpressure(seeSection8fortheEOSTactivationpressures).Adual-pressurehose(7)suppliesairtothewhistlewhenitisactivated,andhasaninternalcapillarytubethatsupplieshigh-pressureairfromthecylindertothegauge.
Theairhosesandthefirst-stageregulatorareintegratedintothespaceframetopreventsnaggingandenhancecomponentprotection.Thehoseclips (2)hold theairhoses inpositionontheshoulderstraps.
Breathing apparatus serial numberThebreathingapparatusserialnumberisonthefirst-stageregulator.
Compressed-air cylinders, lung demand regulators and face masksTheDrägerPSS3000Seriesiscompatiblewithasinglealuminumorcompositematerialcylinderof30to60minutecapacity,andisavailablein2216psior4500psiversions.Fulldescriptionsanduserinstructionsarecontainedinseparateinstructionssuppliedwiththecylinder,facemaskorlungdemandregulator.
2.3 Intended useThe PSS 3000 Series breathing apparatus, when fitted with a cylinder, lung demandregulatorandfacemask,isintendedforuseinapplicationswhereahighlevelofrespiratoryprotection is required. The assembled breathing apparatus provides the wearer withrespiratoryprotectionforworkingincontaminatedoroxygen-deficientconditions.
The cylinder, lung demand regulator, facemask and other accessories usedwith thisproductmustbecertifiedDrägercomponents,assembledinanapprovedconfiguration,otherwise the operation of the device may be impaired. Contact Dräger for furtherinformation.
2.3.1 Limitation
Thisproductisnotapprovedtoprovideprotectionfrommilitarygradechemical,biological,radiological,andnuclearhazards(CBRN).DonotattempttousetheproductforrespiratoryprotectioninCBRNenvironments.
2.4 ApprovalsTheDrägerPSS3000SeriesiscertifiedbyNIOSH.Theapparatusmustonlybeusedinconjunctionwithcompressed-aircylindersapprovedbyNIOSH.
2.5 Explanation of marking and symbolsRefertotherelevantauthorityforexplanationofapprovalbodysymbolsandmarkingontheequipment.Examplesofothermarkingoncomponentpartsofthebreathingapparatusare:
BRAC-1359 – Drägerserialnumber 08/09 – Monthandyearofmanufacture 3356812orR21034 – Drägerpartnumber SF – Standardforcecoupling LF – Lowforcecoupling
3359001 (A3-D-P)
PSS® 3000 SeriesSelf contained breathing apparatus Instructions for Usei
3359001©DrägerSafetyUKLimitedEdition05–March2014(Edition01–June2010)Subject to alteration
4 TroubleshootingThetroubleshootingguideshowsfaultdiagnosisandrepairinformationapplicabletobreathingapparatususers.FurthertroubleshootingandrepairinformationisavailableinInstructionsforUsesuppliedwithassociatedequipment.
Wherethetroubleshootingguideshowsmorethanonefaultorremedy,carryoutrepairactionsintheorderthattheyappearinthetable.
ContactservicepersonnelorDrägerwhentheremedyinformationindicatesaservicetask,orifthesymptomremainsafterallremedyactionshavebeenattempted.
Symptom Fault RemedyFacemaskairleak LungdemandregulatorO-ringleaking
HeadstrapsnottightExhalationvalveleakingSpeechdiaphragmdefective
ReneworlubricateO-ringTightenServicetaskServicetask
Unsatisfactorycommunication Speechdiaphragmdefective ServicetaskHigh-pressureairleakorfailedleaktest Looseordirtyconnector
FaultyhoseorcomponentDisconnect,cleanandreconnectcouplingsandretestSubstitute user replaceable accessories and retest
Airleakfrommedium-pressurehoseconnectionatthefirst-stageregulator(safetyreliefvalve)
FaultyO-ring,retainer,springorfirst-stageregulator Servicetask
Lungdemandregulatorallowingconstantairflowintothefacemask
BypassbuttonengagedInternalfault
Turnoffthebypassbutton(Fig2,Item3)Servicetask
Highorlowmediumpressure First-stageregulatorfault Servicetask
Poorsoundingwhistle Whistledirty Cleanwhistlefluteandretest
Whistlenotfunctioningcorrectly Activationmechanismfault Servicetask
Manufacturer:DraegerSafetyUKLimited Tel +441670352891UllswaterClose,RiversideBusinessPark Fax +441670356266Blyth,NE244RGUnitedKingdom Internethttp://www.draeger.com
USDistributor:DraegerSafety,Inc. Phone 1-800-922-5518101TechnologyDrive Fax 1-800-922-5519PittsburghPA15275 Internethttp://www.draeger.com
6 Storage6.1 Storage preparation● Extendtheshoulderstraps,waistbeltandtheheadharnessstrapsofthefacemask.● Forstorage,placethefacemaskinaprotectivebag(contactDrägerforsupplyofa
suitablebag).● Routerubberhosesinsuchawaythatthebendradiusisnottooacuteandthehoseis
notstretched,compressedortwisted.
6.2 Storage conditions● Storetheequipmentbetween5°Fand77°F(-15°Cand+25°C).Ensurethatthe
environmentisdry,freefromdustanddirt,anddoesnotsubjecttheequipmenttowearordamageduetoabrasion.Donotstoretheequipmentindirectsunlight.
● Fixthebreathingapparatussecurelytoanyraisedmountingpointtopreventitfromfalling.
7 DisposalDisposeofusedbatteriesinaccordancewithnationalorlocalregulations.Whenrequired,dispose of other parts of the breathing apparatus, including electrical and electronicequipment,inlinewithanynationalorlocalenvironmentalregulations.
8 Technical dataCompressed-aircylinders:● 30minutesto60minutescapacity● 2216psior4500psipressure● Aluminumorcompositematerials.
Cylinderhigh-pressureconnectors:● 2216psiconnectortoCGA346● 4500psiconnectortoCGA347.
Lungdemandregulatortofacemaskconnector:● Drägerpush-inconnector.
Whistlewarning(EOST)–Activationcommencementrange:● 2216psicylinder:600psito510psi● 4500psicylinder:1215psito1035psi.
9 Special instructions9.1 Use of an independent air supply (supplied airline
respirator (SAR) connection)
!WARNING
Airqualitymustconformtothestatutoryrequirements.
Useofanairlineconnectionbyasecondperson(buddy-breather)voidsNIOSHapproval.
Thetimerequiredforthewearertoescapetoasafeareamustbewithintheremainingbreathingtimeofthecylinder, taking intoaccounttheremainingaircontentinthecylinderandthebreathingrateofthewearer.
Independentairsuppliesmustmeetthefollowingstandards:● Type-1gaseousairasdefinedin:CGACommoditySpecificationforAir,G-71(gradeD
or higher)● Airsupplypressure:87psito125psi● Airlinehoselength:5feetto300feet(maximumworkinghoselengthmustnotexceed
12 individual hose lengths)● Airlineflowrate:550liters/minute● Approvedforuseattemperaturesabove-25°F(-31.7°C).
1. Turnontheindependentairsupply.2. Connect the independent air supply coupling to the secondary supply hose (see
thePSSSeriesPneumaticAccessories Instructions forUse3355853)andbreathenormally.
3. Closethecylindervalve(ifthewhistlesounds,silenceitbytakingseveralshortdeepbreathsormomentarilyoperating the lungdemand regulatorbypassbutton (Fig2,Item3)).
4. Ifanyairsupplyproblemsareencountered,proceedasfollows: a. Openthecylindervalvetoreturntobreathingfromtheattachedcylinder. b. Disconnecttheindependentairsupplycoupling. c. Leavethehazardousareabytheshortestandsafestescaperoute,ifnecessary.
9.2 Cautions and limitationsD– Air-linerespiratorscanbeusedonlywhentherespiratorsaresuppliedwithrespirable
airmeetingtherequirementsofCGAG–7.1,GradeDorhigherquality.E– UseonlythepressurerangesandhoselengthsspecifiedintheUser’sInstructions.I– Contains electrical parts that may cause an ignition in flammable or explosive
atmospheres.J– Failuretoproperlyuseandmaintainthisproductcouldresultininjuryordeath.M– Allapprovedrespiratorsshallbeselected,fitted,used,andmaintainedinaccordance
withMSHA,OSHA,andotherapplicableregulations.N– Neversubstitute,modify,add,oromitparts.Useonlyexactreplacementpartsinthe
configurationasspecifiedbythemanufacturer.O– RefertoUser’sInstructionsand/ormaintenancemanualsforinformationonuseand
maintenanceoftheserespirators.S– SpecialorcriticalUser’s Instructionsand/orspecificuse limitationsapply.Refer to
User’sInstructionsbeforedonning.
S – Special or Critical Users Instructions
● Approvedforuseattemperaturesabove-25°F(-31.7°C).● Whenusedasacombinationsupplied-airrespirator/self-containedbreathingapparatus
(SAR/SCBA),notmorethan20percentoftheairsupplycanbeusedduringentry.● Duringsuppliedairuse,thecylindervalvemustremainclosed.Ifthesuppliedairfails,
openthecylindervalveandimmediatelyproceedtofreshair.● Suppliedairsourcemustmeetthefollowingcriteria:pressure87psito125psi,airflow
rateatleast550liters/minute.
Important Note: If it is decided to exit the working area with the airline disconnected or, in an emergency, if the air supply fails, breathe normally and immediately proceed as follows:
● Openthecylindervalve(counterclockwise)slowly,butfully,andbreathenormally.● Disconnectthehoseoftheindependentairsupplyfromthemalecouplingoftheairline
hoseconnection.Breathenormallyandimmediatelyleavethehazardousareabytheshortestandsafestroute.
Safety Warning: The remaining duration begins from the time of opening the cylindervalveanddisconnectingtheindependentairsupply.Thetimerequiredtoallow the wearer to escape to a safe area must be within the remaining air capacity (volume)ofthecylindertakingintoaccountthebreathingrateofthewearer.
10 Warranty informationUnlessotherwiseagreedbetweenDrägerandthecustomer,thefollowingshallapplyintheeventofdefectsoftheproductinmaterialorworkmanship:Thecustomershallcontactthecompanywhereheboughttheproduct(“Seller”).ThewarrantyconditionsagreedbetweenthecustomerandtheSellershallapply.TheproductmustbeusedinstrictaccordancewiththeInstructionsforUse.AnyusedisregardingtheInstructionsforUsemayvoidwarranty.
11 Contact detailsAnyissueswiththeequipment,includingdamage,malfunction,orfailureofthebreathingapparatus thatmaypresentahazard to theuser shouldbe reported to thedistributor(DraegerSafety,Inc.).
Contactwiththecertificationorganizationmaybereachedat:NIOSH,NPPTL–Phone1-412-386-4000
5 Maintenance5.1 Maintenance tableServiceandtestthebreathingapparatus,includingout-of-useapparatus,inaccordancewiththemaintenancetable.Recordallservicedetailsandtesting.ReferalsototheInstructionsforUseforthelungdemandregulator,facemaskandotherassociatedequipment.
Additionalinspectionandtestingmayberequiredinthecountryofusetoensurecompliancewithnationalregulations.
Component/System
Task After use
Everymonth
Everyyear
Every10 years
Completeapparatus
Cleananddisinfectifnecessary(seeSection5.2)
Visualinspection(seeSection3.5.1)
Functionaltesting(seeSection3.5.3)
Flowandstatictests(seeNote1)
Lungdemandregulator
Cleananddisinfect(seeNote2andSection5.2)
First-stageregulator
Medium-pressurecheck(seeNote1)
Inspectthesinteredfilter(seeNote1andNote3)
Inspectthehigh-pressureconnectorO-ring(seeNote1andNote4)
Overhaul.ContactDrägerfortheRepairExchange(REX)service(seeNote5)
Cylinder Chargecylindertocorrectworkingpressure(seeSection5.3.1)
Checkchargedpressure(storedcylindersonly)
Checktestdateofcylinder(carboncompositecylindersover15yearsoldmustberetired)
Recertification AccordingtonationalregulationsinthecountryofuseCylindervalve Overhaul Atthetimeofcylinderrecertification
Notes
Drägerrecommendations.
1 ThesemaintenancetasksmayonlybecarriedoutbyDrägerortrainedservicepersonnel.DetailsofthetestsarecontainedintheTechnicalManualwhichisissuedtoservicepersonnelthathaveattendedarelevantDrägermaintenancecourse.
2 LightlylubricatetheO-ringofthelungdemandregulatorasrequired(recommendedlubricantisDowCorning111ValveLubricantandSealant).Productsotherthantherecommendedlubricantarenottestedandmaydam-agetheequipment.
3 Replacethesinteredfilterifadropinfirst-stageregulatorperformanceisobservedduringaflowcheckorifitisvisiblydamaged.4 Replacethehigh-pressureconnectorO-ringifitisfoundtoleakduringfunctionaltestingoriftheO-ringisvisiblydamaged.5 Wherethebreathingapparatusissubjectedtoahighlevelofuse(intrainingestablishmentsetc.),reducetheoverhaulperiodforthefirst-stageregulator.Inthesecircumstances,
Drägerrecommendthattheoverhaulfrequencyshouldbelessthan5,000applicationsofuse.Anapplicationofuseisdefinedasasingleuseofthefullyassembledbreathingapparatus,wheretheuserbreathesfromtheaircylinder.Itdoesnotincludesystempressurizationforpre-operationalchecks.
5.2 Cleaning and disinfecting
!CAUTION
CleaningagentsanddisinfectantslistedbelowarenotmanufacturedbyDrägerandhavebeenreviewedonlyforcompatibilitywhenusedtocleanordisinfectthesubjectDrägerproduct(s).Readandcomplywithallinstructionsforuseprovidedbythemanufacturersofsuchagentsanddisinfectants.Drägerexpresslydisclaimsallresponsibilityforanydamage,personalinjuryorlossresultingfromtheuseofsuchagentsordisinfectants.
Donotexceed86°F(30°C)forwashing,disinfectingandrinsingsolutions.Donotexceed140°F(60°C)fordrying,andremovecomponentsfromthedryingfacilityimmediatelywhendry.Dryingtimeinaheateddryermustnotexceed30minutes.
Donotimmersepneumaticorelectroniccomponentsincleaningsolutionsorwater.
Ifwateristrappedandthenfreezesinsidethepneumaticsystemofthebreathingapparatus(suchasthelungdemandregulator),operationwillbeimpaired.Preventanyliquidfromentering,andthoroughlydrythebreathingapparatusaftercleaningtopreventthisfromoccurring.
Referalsototheinstructionsforthelungdemandregulator,facemaskandotherassociatedequipment.
5.2.1 Manual cleaning of the breathing apparatus (USA)
Cleaning and disinfecting materials:● Cleaningagent–1008GreenLiquidHandDishWash● Disinfectingagent–800Spur-TexDisinfectantCleaner-Deodorant(concentration:1.6%(2flozpergallon))● Useonlycleanlint-freecloths.
1. Preparecleaningsolutionaspermanufacturer’sinstructions.Cleanthebreathingapparatusmanuallyusingaclothmoistenedwithcleaningsolutiontoremoveexcessdirt.2. Preparedisinfectingsolutionaspermanufacturer’sinstructions.Applytoallinternalandexternalsurfaces,ensuringthatallsurfacesremainvisiblywetfor15minutes.3. Rinseallcomponentsthoroughlywithcleanwatertoremoveallcleaninganddisinfectingagents.4. Dryallcomponentsusingadrycloth,inaheateddryerorinair.5. ContactservicepersonnelorDrägerifdisassemblyofpneumaticorelectroniccomponentsisrequired.
5.2.2 Manual cleaning of the breathing apparatus (Canada)
Cleaning and disinfecting materials:● Cleaningagent–mildsoapsolution● Disinfectingagent–NeutralDisinfectantCleaner(concentration:0.5%(0.5flozpergallonor15mlper3.785liters))● Useonlycleanlint-freecloths.
1. Preparecleaningsolutionaspermanufacturer’sinstructions.Cleanthebreathingapparatusmanuallyusingaclothmoistenedwithcleaningsolutiontoremoveexcessdirt.2. Preparedisinfectingsolutionaspermanufacturer’sinstructions.Applytoallinternalandexternalsurfaces,ensuringthatallsurfacesremainvisiblywetfor10minutes.3. Rinseallcomponentsthoroughlywithcleanwatertoremoveallcleaninganddisinfectingagents.4. Dryallcomponentsusingadrycloth,inaheateddryerorinair.5. ContactservicepersonnelorDrägerifdisassemblyofpneumaticorelectroniccomponentsisrequired.
5.3 Maintenance work5.3.1 Air cylinder charging
!WARNING
Airqualityforcompressed-aircylindersmustconformtotheminimumgraderequirementsforType1gaseousairasdefinedintheCGACommoditySpecificationforAir,G-7.1(GradeDorhigherquality).
Refertotheinstructionssuppliedwiththecylinderandthechargingapparatusforrechargingacompressed-aircylinder.