Upload
trinhcong
View
219
Download
1
Embed Size (px)
Citation preview
2
1
3
4
5
6
7
8
9
10
2
1
3
4
5
6
7
8
9
10
0517Q-EN.indd version: 3.022
Selection guide Ethernet networkCabling systemConneXium hub and transceiver
Type of device Hub
Interfaces Copper cable ports Number and type 4 x 10BASE-T portsShielded connectors RJ45Medium Shielded twisted pair, category CAT 5ETotal length of pair 100 m
Fibre optic ports Number and type –Connectors –Medium –
Length of optical fi bre 50/125 μm –62.2/125 μm –
Optical fi bre attenuation analysis
50/125 μm fi bre –62.2/125 μm fi bre –
Topology Number of hubs Cascaded Up to 4In a ring –
Redundancy P1 and P2 redundant power supplies
Power supply Voltage 24 V c (18…32) safety extra low voltage (SELV)Consumption 80 mA (130 max. at 24 V c)Removable terminal block 5 terminals
Operating temperature 0…+ 60°C
Relative humidity 10… 95% non condensing
Degree of protection IP 30
Dimensions W x H x D 40 x 125 x 80 mm
Mounting On symmetrical DIN rail, 35 mm wide
Weight 0.530 kg
Conforming to standards cUL 60950, UL 508 and CSA 22.2 No. 142, UL 1604 and CSA 22.2 No. 213 class 1 division 2, e, GL, C-TickFM 3810, FM 3611 class 1 division 2
LED indicators Power supply, activity, link
Alarm relay Power supply fault, Ethernet network fault or communication port fault (volt-free contact 1 A max. at 24 V c)
Reference 499 NEH 104 10
Page 48384/6
2
1
3
4
5
6
7
8
9
10
2
1
3
4
5
6
7
8
9
10
0517Q-EN.indd version: 3.0 33
Transceiver
1 x 100BASE-TX portRJ45Shielded twisted pair, category CAT 5E100 m1 x 100BASE-FX portSCMultimode optical fi bre3000 m (1)3000 m (1)8 dB11 dB
––
P1 and P2 redundant power supplies
24 V c (18…32) safety extra low voltage (SELV)160 mA (190 max. at 24 V c)5 terminals
0…+ 60°C
10… 95% non condensing
IP 20
47 x 135 x 111 mm
On symmetrical DIN rail, 35 mm wide
0.230 kg
cUL 60950, UL 508 and CSA 22.2 No. 142, UL 1604 and CSA 22.2 No. 213 Class 1 Division 2, e, GL, C-Tick
P1 and P2 power supplies, Ethernet link/port status
Power supply fault, Ethernet network fault or communication port fault (volt-free contact 1 A max. at 24 V c)
499 NTR 101 00
48384/6(1) Length dependent on the attenuation analysis and attenuation of the optical fi bre (typical value: 2000 m).
2
1
3
4
5
6
7
8
9
10
2
1
3
4
5
6
7
8
9
10
0517Q-EN.indd version: 3.044
Selection guide (continued) Ethernet networkCabling systemConneXium unmanaged switches
Type of device Unmanaged switches, copper twisted pair
Interfaces Copper cable ports Number and type 5 x 10BASE-T/100BASE-TX ports 8 x 10BASE-T/100BASE-TX portsShielded connectors M12 (type D) RJ45Medium Shielded twisted pair, category CAT 5E
Total length of pair 100 mFibre optic ports Number and type –
Connectors –Medium –
Length of optical fi bre 50/125 μm –62.2/125 μm –
Optical fi breattenuation analysis
50/125 μm fi bre –
62.2/125 μm fi bre –Ethernet services Storage and re-routing of received data,
auto MDI/MDX, automatic negotiation of 10/100 Mbps and duplex mode (on all ports)
–
Topology Number of switches Cascaded UnlimitedRedundant in a ring –
Redundancy – P1 and P2 redundant power supplies
Power supply Voltage 24 V c (18…32) safety extra low voltage (SELV)Consumption 100 mA max. 125 mA (290 mA max.)Removable terminal block 5 terminals, M12 (type A, male) 5 terminals
Operating temperature 0…+ 60°C
Relative humidity – 10… 95% non condensing
Degree of protection IP 67 IP 20
Dimensions W x H x D 60 x 126 x 31 mm 47 x 135 x 111 mm
Mounting On a fl at surface On symmetrical DIN rail, 35 mm wide
Weight 0.210 kg 0.230 kg
Conforming to standards cUL 508 and CSA 22.2 No. 142 cUL 60950, UL 508 and CSA 22.2 No. 142, UL 1604 and CSA 22.2 No. 213 class 1 division 2, e, GL, C-Tick
LED indicators Power supply, link status, data rate P1 and P2 power supplies, Ethernet link/port status
Alarm relay – Power supply fault, Ethernet network fault or communication port fault (volt-free contact 1 A max. at 24 V c)
Reference TCS ESU 051F0 499 NES 181 00
Page 48384/7
2
1
3
4
5
6
7
8
9
10
2
1
3
4
5
6
7
8
9
10
0517Q-EN.indd version: 3.0 55
Unmanaged switches, copper twisted pair (continued)
Unmanaged switches, 4 and 5 ports, copper twisted pair and fi bre optic
8 x 10BASE-T/100BASE-TX ports 3 x 10BASE-T/100BASE-TX ports 4 x 10BASE-T/100BASE-TX ports 5 x 10BASE-T/100BASE-TX ports RJ45 RJ45Shielded twisted pair, category CAT 5E
Shielded twisted pair, category CAT 5E
100 m 100 m– – 1 x 100BASE-FX port –– – Duplex SC –– – Multimode optical fi bre –– – 5000 m (1) –– – 4000 m (1) –– – 8 dB –
– – 11 dBStorage and re-routing of received data, auto MDI/MDX, automatic negotiation of 10/100 Mbps and duplex mode (on all ports), automatic change of polarity
Storage and re-routing of received data, auto MDI/MDX, automatic negotiation of 10/100 Mbps and duplex mode (on all ports)
Unlimited Unlimited– –
– –
24 V c (9.6…32) SELV 24 V c (9.6…32 V) safety extra low voltage (SELV)4.1 W max. 2.2 W max. 3.9 W max. 2.2 W max.3 terminals Removable screw terminal block, 3 terminals
0…+ 60°C 0…+ 60°C
95% max. non condensing 95% max. non condensing
IP 30 IP 30
35 x 138 x 121 mm 25 x 114 x 79 mm
On symmetrical DIN rail, 35 mm wide
0.246 kg 0.113 kg 0.120 kg 0.113 kg
UL 508 and CSA 22.2 No.142IEC/EN 61131-2, IEC 60825-1 class 1, CISPR 11A
UL 508 and CSA 22.2 No. 142IEC/EN 61131-2, IEC 60825-1 class 1, CISPR 11A
Power supply, copper port activity, 10 or 100 Mbps data rate
Power supply, copper port activity, 10 or 100 Mbps data rate
– Fibre port activity and status –
– –
TCS ESU 083FN0 TCS ESU 033FN0 TCS ESU 043F1N0 TCS ESU 053FN0
48384/7 48384/8(1) Length dependent on the attenuation analysis and attenuation of the optical fi bre (typical value: 2000 m).
2
1
3
4
5
6
7
8
9
10
2
1
3
4
5
6
7
8
9
10
0517Q-EN.indd version: 3.066
Type of device Unmanaged switches, 5 ports, copper twisted pair and fi bre optic
Interfaces Copper cable ports Number and type 4 x 10BASE-T/100BASE-TX ports
3 x 10BASE-T/100BASE-TX ports
4 x 10BASE-T/100BASE-TX ports
3 x 10BASE-T/100BASE-TX ports
Shielded connectors RJ45Medium Shielded twisted pair, category CAT 5ETotal length of pair 100 m
Fibre optic ports Number and type 1 x 100BASE-FX port
2 x 100BASE-FX ports
1 x 100BASE-FX port
2 x 100BASE-FX ports
Connectors SCMedium Multimode optical fi bre Single mode optical fi bre
Length of optical fi bre 50/125 μm 5000 m (1) –62.2/125 μm 4000 m (1) –9/125 μm fi bre – 32,500 m (2)
Optical fi breattenuation analysis
50/125 μm fi bre 8 dB –62.2/125 μm fi bre 11 dB –9/125 μm fi bre – 16 dB
Ethernet services –
Topology Number of switches Cascaded UnlimitedRedundant in a ring –
Redundancy P1 and P2 redundant power supplies
Power supply Voltage 24 V c (18…32 V) safety extra low voltage (SELV)Consumption 200 mA max. 240 mA max. 200 mA max. 240 mA max.Removable terminal block 5 terminals
Operating temperature - 40...+ 70°C
Relative humidity 10… 95% non condensing
Degree of protection IP 20
Dimensions W x H x D 47 x 135 x 111 mm
Mounting On symmetrical DIN rail, 35 mm wide
Weight 0.330 kg 0.335 kg 0.330 kg 0.335 kg
Conforming to standards cUL 60950, cUL 508 and CSA 22.2 No. 142, UL 1604 and CSA 22.2 No. 213 class 1 division 2, e, GL, C-Tick
LED indicators P1 and P2 power supplies, Ethernet link status, transmission activity
Alarm relay Activity, power supply fault, Ethernet network fault or communication port fault (volt-free contact 1 A max. at 24 V c)
Reference 499 NMS 251 01 499 NMS 251 02 499 NSS 251 01 499 NSS 251 02
Page 48384/8(1) Length dependent on the attenuation analysis and attenuation of the optical fi bre (typical
value: 2000 m).(2) Length dependent on the attenuation analysis and attenuation of the optical fi bre (typical
value: 15,000 m).
Selection guide (continued) Ethernet networkCabling systemManaged and unmanaged ConneXium switches
2
1
3
4
5
6
7
8
9
10
2
1
3
4
5
6
7
8
9
10
0517Q-EN.indd version: 3.0 77
Managed switches, 4 ports, copper twisted pair and fi bre optic
3 x 10/100BASE-TX ports 2 x 10/100BASE-TX ports 3 x 10/100BASE-TX ports 2 x 10/100BASE-TX ports
RJ45Shielded twisted pair, category CAT 5E100 m1 x 100BASE-FX port 2 x 100BASE-FX ports 1 x 100BASE-FX port 2 x 100BASE-FX ports
Duplex SCMultimode optical fi bre Single mode optical fi bre5000 m (1) –4000 m (1) –– 32,500 m (2)8 dB –11 dB –– 16 dBFDR, SMTP V3, SNTP client, multicast fi ltering for optimization of the Global Data protocol, confi guration via Web access,VLAN, IGMP Snooping, RSTP (Rapid Scanning Tree Protocol), priority port, data stream control, secure port
UnlimitedUp to 50
Redundant power supplies, redundant single ring, ring coupling
9.6...60 V c/18…30 V a safety extra low voltage (SELV)6.5 W 7.3 W 6.5 W 7.3 W6 terminals
0…+ 60°C
10… 90% non condensing
IP 20
47 x 131 x 111 mm
On symmetrical DIN rail, 35 mm wide
0.400 kg
IEC 61131-2, UL 508, UL 1604 class 1 division 2, CSA 22.2 No. 142 (cUL), CSA 22.2 No. 213 class 1 division 2 (cUL), e, GL, C-Tick
Power supply status, alarm relay status, active redundancy, redundancy management, copper port status and copper port activity
Power supply fault, Ethernet network fault, communication port fault, redundancy fault (volt-free contact 1 A max. at 24 V c)
TCS ESM 043F1CU0 TCS ESM 043F2CU0 TCS ESM 043F1CS0 TCS ESM 043F2CS0
48384/9(1) Length dependent on the attenuation analysis and attenuation of the optical fi bre (typical value: 2000 m).(2) Length dependent on the attenuation analysis and attenuation of the optical fi bre (typical value: 15,000 m).
2
1
3
4
5
6
7
8
9
10
2
1
3
4
5
6
7
8
9
10
0517Q-EN.indd version: 3.088
Type of device Managed switches, 4 and 8 ports, copper twisted pair
Interfaces Copper cable ports Number and type 4 x 10/100BASE-TX ports 8 x 10/100BASE-TX ports
Shielded connectors RJ45Medium Shielded twisted pair, category CAT 5ETotal length of pair 100 m
Fibre optic ports Number and type –Connectors –Medium –
Length of optical fi bre 50/125 μm –62.2/125 μm –9/125 μm fi bre –
Attenuation analysis 50/125 μm fi bre –62.2/125 μm fi bre –9/125 μm fi bre –
Ethernet services FDR, SMTP V3, SNTP client, multicast fi ltering for optimization of the Global Data protocol, confi guration via Web access, VLAN, IGMP Snooping, RSTP (Rapid Scanning Tree Protocol), priority port, data stream control, secure port
Topology Number of switches Cascaded UnlimitedRedundant in a ring Up to 50
Redundancy P1 and P2 redundant power supplies, redundant single ring, ring coupling
Power supply Voltage 9.6...60 V c/18…30 V a safety extra low voltage (SELV)Consumption 5.3 WRemovable terminal block 6 terminals
Operating temperature 0...+ 60°C
Relative humidity 10… 90% non condensing
Degree of protection IP 20
Dimensions W x H x D 47 x 131 x 111 mm 74 x 131 x 111 mm
Mounting On symmetrical DIN rail, 35 mm wide
Weight 0.400 kg 0.410 kg
Conforming to standards IEC/EN 61131-2, UL 508, UL 1604 class 1 division 2, CSA 22.2 No. 214 (cUL), CSA 22.2 No. 213 class 1 division 2 (cUL), e, GL, C-Tick
LED indicators Power supply status, alarm relay status, active redundancy, redundancy management, copper port status and copper port activity
Power supply status, alarm relay status, active redundancy, redundancy management, fi bre port status and fi bre port activity
Alarm relay Power supply fault, Ethernet network fault or communication port fault (volt-free contact 1 A max. at 24 V c)
Reference TCS ESM 043F23F0 TCS ESM 083F23F0
Page 48384/9
Selection guide (continued) Ethernet networkCabling systemConneXium managed switches
2
1
3
4
5
6
7
8
9
10
2
1
3
4
5
6
7
8
9
10
0517Q-EN.indd version: 3.0 99
Managed switches, 8 ports, copper twisted pair and fi bre optic
7 x 10/100BASE-TX ports 6 x 10/100BASE-TX ports 7 x 10/100BASE-TX ports 6 x 10/100BASE-T ports
RJ45Shielded twisted pair, category CAT 5E100 m1 x 100BASE-FX port 2 x 100BASE-FX ports 1 x 100BASE-FX port 2 x 100BASE-FX portsDuplex SCMultimode optical fi bre Single mode optical fi bre5000 m (1) –4000 m (1) –– 32,500 m (2)8 dB –11 dB –– 16 dBFDR, SMTP V3, SNTP client, multicast fi ltering for optimization of the Global Data protocol, confi guration via Web access,VLAN, IGMP Snooping, RSTP (Rapid Scanning Tree Protocol), priority port, data stream control, secure port
UnlimitedUp to 50
Redundant power supplies, redundant single ring, ring coupling
9.6...60 V c/18…30 V a safety extra low voltage (SELV)6.5 W 7.3 W 6.5 W 7.3 W6 terminals
0…+ 60°C
10… 90% non condensing
IP 20
75 x 131 x 111 mm
On symmetrical DIN rail, 35 mm wide
0.410 kg
IEC/EN 61131-2, UL 508, UL 1604 class 1 division 2, CSA 22.2 No. 214 (cUL), CSA 22.2 No. 213 class 1 division 2 (cUL), e, GL, C-Tick
Power supply status, alarm relay status, active redundancy, redundancy management, fi bre port status and fi bre port activity
Power supply fault, Ethernet network fault or communication port fault (volt-free contact 1 A max. at 24 V c)
TCS ESM 083F1CU0 TCS ESM 083F2CU0 TCS ESM 083F1CS0 TCS ESM 083F2CS0
48384/10(1) Length dependent on the attenuation analysis and attenuation of the optical fi bre (typical value: 2000 m).(2) Length dependent on the attenuation analysis and attenuation of the optical fi bre (typical value: 15,000 m).
2
1
3
4
5
6
7
8
9
10
2
1
3
4
5
6
7
8
9
10
0517Q-EN.indd version: 3.01010
Type of device Basic managed switch, 8 ports, copper twisted pair
Interfaces Copper cable ports Number and type 8 x 10/100BASE-TX portsShielded connectors RJ45Medium Shielded twisted pair, category CAT 5ETotal length of pair 100 m
Fibre optic ports Number and type –Connectors –Medium –
Length of optical fi bre 50/125 μm –62.2/125 μm –9/125 μm fi bre –
Attenuation analysis 50/125 μm fi bre –62.2/125 μm fi bre –9/125 μm fi bre –
Ethernet services FDR, SNTP client, multicast fi ltering for optimization of the Global Data protocol, confi guration via Web access, IGMP Snooping, RSTP (Rapid Scanning Tree Protocol), priority port
Topology Number of switches Cascaded UnlimitedRedundant in a ring Up to 50
Redundancy P1 and P2 redundant power supplies, redundant single ring, ring coupling
Power supply Voltage 9.6...32 V c safety extra low voltage (SELV)Consumption 6 WRemovable terminal block 6 terminals
Operating temperature 0...+ 60°C
Relative humidity 95% max. non condensing
Degree of protection IP 20
Dimensions W x H x D 47 x 131 x 111 mm
Mounting On symmetrical DIN rail, 35 mm wide
Weight 0.400 kg
Conforming to standards IEC/EN 61131-2, UL 508, UL 1604 class 1 division 2, CSA 22.2 No. 214 (cUL), CSA 22.2 No. 213 class 1 division 2 (cUL), e, GL, C-Tick
LED indicators Power supply status, alarm relay status, active redundancy, redundancy management, copper port status and copper port activity
Alarm relay Power supply fault, Ethernet network fault or communication port fault (volt-free contact 1 A max. at 24 V c)
Reference TCS ESB 083F23F0
Page 48384/10
Selection guide (continued) Ethernet networkCabling systemBasic ConneXium managed switches
2
1
3
4
5
6
7
8
9
10
2
1
3
4
5
6
7
8
9
10
0517Q-EN.indd version: 3.0 1111
Basic managed switches, 8 and 9 ports, copper twisted pair and fi bre optic
6 x 10/100BASE-TX ports 6 x 10/100BASE-TX portsRJ45Shielded twisted pair, category CAT 5E100 m2 x 100BASE-FX ports 3 x 100BASE-FX portsDuplex SCMultimode optical fi bre5000 m (1)4000 m (1)–8 dB11 dB–FDR, SNTP client, multicast fi ltering for optimization of the Global Data protocol, confi guration via Web access, IGMP Snooping, RSTP (Rapid Scanning Tree Protocol), priority port
UnlimitedUp to 50
P1 and P2 redundant power supplies, redundant single ring, ring coupling
9.6...32 V c safety extra low voltage (SELV)8 W 9 W6 terminals
0…+ 60°C
95% max. non condensing
IP 20
74 x 131 x 111 mm
On symmetrical DIN rail, 35 mm wide
0.400 kg
IEC/EN 61131-2, UL 508, UL 1604 class 1 division 2, CSA 22.2 No. 214 (cUL), CSA 22.2 No. 213 class 1 division 2 (cUL), e, GL, C-Tick
Power supply status, alarm relay status, active redundancy, redundancy management, fi bre port status and fi bre port activity
Power supply fault, Ethernet network fault or communication port fault (volt-free contact 1 A max. at 24 V c)
TCS ESB 083F2CU0 TCS ESB 093F2CU0
48384/10(1) Length dependent on the attenuation analysis and attenuation of the optical fi bre (typical value: 2000 m).(2) Length dependent on the attenuation analysis and attenuation of the optical fi bre (typical value: 15,000 m).
2
1
3
4
5
6
7
8
9
10
2
1
3
4
5
6
7
8
9
10
0517Q-EN.indd version: 3.01212
Selection guide (continued) Ethernet networkCabling systemConneXium managed switches
Type of device Managed switches, 8 extended ports, copper twisted pair and fi bre optic
Interfaces Copper cable ports Number and type 8 x 10/100BASE-TX ports 6 x 10/100BASE-TX ports 6 x 10/100BASE-T portsShielded connectors RJ45Medium Shielded twisted pair, category CAT 5ETotal length of pair 100 m
Fibre optic ports Number and type – 2 x 100BASE-FX portsConnectors – Duplex SCMedium – Multimode optical fi bre Single mode optical fi bre
Length of optical fi bre 50/125 μm – 5000 m (1) –62.2/125 μm – 4000 m (1) –9/125 μm fi bre – – 32,500 m (2)
Attenuation analysis 50/125 μm fi bre – 8 dB –62.2/125 μm fi bre – 11 dB –9/125 μm fi bre – – 16 dB
Ethernet services FDR, SMTP V3, SNTP client, multicast fi ltering for optimization of the Global Data protocol, confi guration via Web access,VLAN, IGMP Snooping, RSTP (Rapid Scanning Tree Protocol), priority port, data stream control, secure port
Topology Number of switches Cascaded UnlimitedRedundant in a ring Up to 50
Redundancy Redundant power supplies, redundant single ring, ring coupling, rings supporting MRP, Fast Hiper Ring and RSTP
Power supply Voltage 18...60 V c Consumption 10 W 12 WRemovable terminal block 2 terminal blocks, 2 terminals
Operating temperature 0...+ 60°C
Relative humidity 10… 90% non condensing
Degree of protection IP 30
Dimensions W x H x D 120 x 137 x 115 mm
Mounting On symmetrical DIN rail, 35 mm wide
Weight 1 kg
Conforming to standards IEC/EN 61131-2, IEC 61850-3, UL 508, UL 1604 class 1 division 2, CSA 22.2 No. 214 (cUL), CSA 22.2 No. 213 class 1 division 2 (cUL), e, GL, C-Tick, LR, BV
LED indicators Power supply status, alarm relay status, active redundancy, redundancy management, copper port status and copper port activity
Alarm relay Power supply fault, Ethernet network fault or communication port fault (volt-free contact 1 A max. at 24 V c, 2-way)
Reference TCS ESM 083F23F1 TCS ESM 063F2CU1 TCS ESM 063F2CS1
Page 48384/10(1) Length dependent on the attenuation analysis and attenuation of the optical fi bre (typical
value: 2000 m).(2) Length dependent on the attenuation analysis and attenuation of the optical fi bre (typical
value: 15,000 m).
2
1
3
4
5
6
7
8
9
10
2
1
3
4
5
6
7
8
9
10
0517Q-EN.indd version: 3.0 1313
Managed switches, 16 and 24 ports, copper twisted pair and fi bre optic
16 x 10/100BASE-TX ports 14 x 10/100BASE-TX ports 14 x 10/100BASE-TX ports 22 x 10/100BASE-TX portsRJ45Shielded twisted pair, category CAT 5E100 m– 2 x 100BASE-FX ports– Duplex SC– Multimode optical fi bre Single mode optical fi bre Multimode optical fi bre– 5000 m (1) – 5000 m (1)– 4000 m (1) – 4000 m (1)– – 32,500 m (2) –– 8 dB – 8 dB– 11 dB – 11 dB– – 16 dB –FDR, SMTP V3, SNTP client, multicast fi ltering for optimization of the Global Data protocol, confi guration via Web access,VLAN, IGMP Snooping, RSTP (Rapid Scanning Tree Protocol), priority port, data stream control, secure port
UnlimitedUp to 50
Redundant power supplies, redundant single ring, ring coupling
9.6...60 V c/18…30 V a safety extra low voltage (SELV)9.4 W 11.8 W 11.8 W 15.5 W6 terminals
0…+ 60°C
10… 90% non condensing 95% max. non condensing 10… 90% non condensing
IP 20
111 x 131 x 111 mm
On symmetrical DIN rail, 35 mm wide
0.600 kg 0.650 kg
cUL 60950, UL 508 and CSA 22.2 No. 142, UL 1604 and CSA 22.2 No. 213 class 1 division 2
IEC/EN 61131-2, UL 508, UL 1604 class 1 division 2, CSA 22.2 No. 214 (cUL), CSA 22.2 No. 213 class 1 division 2 (cUL), e, GL, C-Tick
cUL 60950, UL 508 and CSA 22.2 No. 142, UL 1604 and CSA 22.2 No. 213 class 1 division 2
Power supply status, alarm relay status, active redundancy, redundancy management, copper port status and copper port activity
Power supply status, alarm relay status, active redundancy, redundancy management, fi bre port status and fi bre port activity
Power supply fault, Ethernet network fault or communication port fault (volt-free contact 1 A max. at 24 V c)
TCS ESM 163F23F0 TCS ESM 163F2CU0 TCS ESM 163F2CS0 TCS ESM 243F2CU0
48384/11(1) Length dependent on the attenuation analysis and attenuation of the optical fi bre (typical value: 2000 m).
2
1
3
4
5
6
7
8
9
10
2
1
3
4
5
6
7
8
9
10
0517Q-EN.indd version: 3.01414
Selection guide (continued) Ethernet networkCabling systemConneXium managed switches
Type of device Managed switch, 8 ports and 2 Gigabit ports, copper twisted pair and fi bre optic
Interfaces Copper cable ports Number and type 8 x 10/100BASE-TX ports
Shielded connectors RJ45Medium Shielded twisted pair, category CAT 5ETotal length of pair 100 m
Fibre opticGigabit ports(with SFP fi bre optic module to be mounted on SFP connector)
Number and type 2 x 1000BASE-SX ports (1) 2 x 1000BASE-LH ports (2) 2 x 1000BASE-LX ports (3)Connectors LCMedium Multimode optical fi bre Single mode optical fi bre Single mode and multimode
optical fi bre
Length of optical fi bre 50/125 μm 550 m – 550 m62.2/125 μm 275 m – 550 m9/125 μm fi bre – 8 - 72,000 m 20,000 m
Attenuation analysis 50/125 μm fi bre 7.5 dB – 11 dB62.2/125 μm fi bre 7.5 dB – 11 dB9/125 μm fi bre – 6 - 22 dB 11 dB
Ethernet services FDR, SMTP V3, SNTP client, multicast fi ltering for optimization of the Global Data protocol, confi guration via Web access, VLAN, IGMP Snooping, RSTP (Rapid Scanning Tree Protocol), priority port, data stream control, secure port
Topology Number of switches Cascaded UnlimitedRedundant in a ring Up to 50
Redundancy Redundant power supplies, redundant single ring, ring coupling
Power supply Voltage 9.6...60 V c/18…30 V a safety extra low voltage (SELV)Consumption 8.9 W + 1 W per SFP fi bre optic moduleRemovable terminal block 6 terminals
Operating temperature 0...+ 60°C
Relative humidity 10… 90% non condensing
Degree of protection IP 20
Dimensions W x H x D 111 x 131 x 111 mm
Mounting On symmetrical DIN rail, 35 mm wide
Weight 0.410 kg
Conforming to standards cUL 60950, UL 508 and CSA 22.2 No. 142, UL 1604 and CSA 22.2 No. 213 class 1 division 2, e, GL
LED indicators Power supply status, alarm relay status, active redundancy, redundancy management, fi bre port status and fi bre port activity
Alarm relay Power supply fault, Ethernet network fault or communication port fault (volt-free contact 1 A max. at 24 V c)
Reference TCS ESM 103F23G0
Page 48384/11(1) With TCS EAA F1LFU00 fi bre optic module to be ordered separately (see page 48384/5).(2) With TCS EAA F1LFH00 fi bre optic module to be ordered separately (see page 48384/5).(3) With TCS EAA F1LFS00 fi bre optic module to be ordered separately (see page 48384/5).
2
1
3
4
5
6
7
8
9
10
2
1
3
4
5
6
7
8
9
10
0517Q-EN.indd version: 3.0 1515
Managed switch, 8 ports and 2 Gigabit ports, copper twisted pair
8 x 10/100BASE-TX ports and 2 x 10/100/1000BASE-TX ports (Gigabit)RJ45Shielded twisted pair, category CAT 5E100 m–LC–
––––––FDR, SMTP V3, SNTP client, multicast fi ltering for optimization of the Global Data protocol, confi guration via Web access, VLAN, IGMP Snooping, RSTP (Rapid Scanning Tree Protocol), priority port, data stream control, secure port
UnlimitedUp to 50
Redundant power supplies, redundant single ring, ring coupling
9.6...60 V c/18…30 V a safety extra low voltage (SELV)8.3 W6 terminals
0...+ 60°C
10… 90% non condensing
IP 20
111 x 131 x 111 mm
On symmetrical DIN rail, 35 mm wide
0.410 kg
cUL 60950, UL 508 and CSA 22.2 No. 142, UL 1604 and CSA 22.2 No. 213 class 1 division 2, e, GL
Power supply status, alarm relay status, active redundancy, redundancy management, fi bre port status and fi bre port activity
Power supply fault, Ethernet network fault or communication port fault (volt-free contact 1 A max. at 24 V c)
TCS ESM 103F2LG0
48384/11