17
Journal of Soft Computing in Civil Engineering 1-2 (2017) 35-51 How to cite this article: Ismaeil M, Elhadi Kh, Alashker Y, Yousef IE. Seismic analysis and design of a multi-storey building located in Haql city, KSA. J Soft Comput Civ Eng 2017;1(2):3551. https://doi.org/10.22115/scce.2017.49083. 2588-2872/ © 2017 The Authors. Published by Pouyan Press. This is an open access article under the CC BY license (http://creativecommons.org/licenses/by/4.0/). Contents lists available at SCCE Journal of Soft Computing in Civil Engineering Journal homepage: www.jsoftcivil.com Seismic Analysis and Design of a Multi-Storey Building Located in Haql City, KSA M. Ismaeil 1* , Kh. Elhadi 2 , Y. Alashker 2 , I.E. Yousef 3 1. Assistant Professor, Department of Civil Engineering, King Khalid University, KSA. On leave from Sudan University for Science and Technology, Khartoum, Sudan 2. Assistant Professor, Department of Civil Engineering, King Khalid University, KSA. On leave from Structural Engineering Department, Zagazig University, Zagazige, Egypt 3. Lecturer, Department of Civil Engineering, King Khalid University, KSA Corresponding author: [email protected] https://doi.org/10.22115/SCCE.2017.49083 ARTICLE INFO ABSTRACT Article history: Received: 29 July 2017 Revised: 02 August 2017 Accepted: 02 August 2017 Recently the design of RC building to mitigate seismic loads has received great attention. Since Saudi Arabia has low to moderate seismicity, most of the buildings were designed only for gravity load. The objective of this paper is to analysis design RC building located in the most active seismic zone region in Saudi Arabia to mitigate seismic loads. A multi-story reinforced concrete building, in Haql city, was seismically analyzed and designed using the Equivalent Lateral Force Procedure with the aid of SAP200 software. The chosen buildings which were Ordinary Moment Resisting Frame (OMR), was analyzed and designed by using SBC 301 (2007) Saudi Building Code [1], SAP2000 (structural analysis software) [2] and ISACOL "Information Systems Application on Reinforced Concrete Columns" [3]. The results showed that the current design of RC buildings located in the most active seismic zone region in Saudi Arabia, Haql city was found unsafe, inadequate and unsatisfied to mitigate seismic loads. Keywords: SAP2000; SBC 301 (2007); Active seismic zone region; Saudi Arabia; Equivalent static method; Seismic loads.

Seismic Analysis and Design of a Multi-Storey Building ...€¦ · designed by using SBC 301 (2007) Saudi Building Code [1], SAP2000 (structural analysis software) [2] and ISACOL

  • Upload
    others

  • View
    5

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Seismic Analysis and Design of a Multi-Storey Building ...€¦ · designed by using SBC 301 (2007) Saudi Building Code [1], SAP2000 (structural analysis software) [2] and ISACOL

Journal of Soft Computing in Civil Engineering 1-2 (2017) 35-51

How to cite this article: Ismaeil M, Elhadi Kh, Alashker Y, Yousef IE. Seismic analysis and design of a multi-storey building

located in Haql city, KSA. J Soft Comput Civ Eng 2017;1(2):35–51. https://doi.org/10.22115/scce.2017.49083.

2588-2872/ © 2017 The Authors. Published by Pouyan Press.

This is an open access article under the CC BY license (http://creativecommons.org/licenses/by/4.0/).

Contents lists available at SCCE

Journal of Soft Computing in Civil Engineering

Journal homepage: www.jsoftcivil.com

Seismic Analysis and Design of a Multi-Storey Building Located

in Haql City, KSA

M. Ismaeil1*

, Kh. Elhadi2, Y. Alashker

2, I.E. Yousef

3

1. Assistant Professor, Department of Civil Engineering, King Khalid University, KSA. On leave from Sudan

University for Science and Technology, Khartoum, Sudan

2. Assistant Professor, Department of Civil Engineering, King Khalid University, KSA. On leave from Structural

Engineering Department, Zagazig University, Zagazige, Egypt

3. Lecturer, Department of Civil Engineering, King Khalid University, KSA

Corresponding author: [email protected]

https://doi.org/10.22115/SCCE.2017.49083

ARTICLE INFO

ABSTRACT

Article history:

Received: 29 July 2017

Revised: 02 August 2017

Accepted: 02 August 2017

Recently the design of RC building to mitigate seismic loads

has received great attention. Since Saudi Arabia has low to

moderate seismicity, most of the buildings were designed

only for gravity load. The objective of this paper is to

analysis design RC building located in the most active

seismic zone region in Saudi Arabia to mitigate seismic

loads. A multi-story reinforced concrete building, in Haql

city, was seismically analyzed and designed using the

Equivalent Lateral Force Procedure with the aid of SAP200

software. The chosen buildings which were Ordinary

Moment Resisting Frame (OMR), was analyzed and

designed by using SBC 301 (2007) Saudi Building Code [1],

SAP2000 (structural analysis software) [2] and ISACOL

"Information Systems Application on Reinforced Concrete

Columns" [3]. The results showed that the current design of

RC buildings located in the most active seismic zone region

in Saudi Arabia, Haql city was found unsafe, inadequate and

unsatisfied to mitigate seismic loads.

Keywords:

SAP2000;

SBC 301 (2007);

Active seismic zone region;

Saudi Arabia;

Equivalent static method;

Seismic loads.

Page 2: Seismic Analysis and Design of a Multi-Storey Building ...€¦ · designed by using SBC 301 (2007) Saudi Building Code [1], SAP2000 (structural analysis software) [2] and ISACOL

36 M. Ismaeil et al./ Journal of Soft Computing in Civil Engineering 1-2 (2017) 35-51

1. Introduction

Haql is a town in the northwest of Saudi Arabia near the head of the Gulf of Aqaba, adjacent to

Aqaba across the Jordanian border. The coasts of Egypt, Israel, and Jordan, can be seen from

Haql. Haql city is located in the most active seismic zone region of the Kingdom of Saudi Arabia

where there is a complicated geological structure and tectonics. This paper is an attempt to study

the effect of seismic loads on RC residential buildings located in the most active seismic zone

region of the Kingdom of Saudi Arabia. Saudi Arabia is not free from earthquakes. It has

experienced many earthquakes during the recent history, and the previous studies in this field

demonstrated this argument. Most of the existing buildings in Saudi Arabia do not meet the

current design standards due to design shortage or construction shortcomings.

The last major event was the 1995 Haql earthquake in the Gulf of Aqaba (magnitude 7.3) which

caused significant damage on both sides of the Gulf and was felt hundreds of kilometers away.

As far as Saudi Arabia is concerned, the most active area is along the Gulf of Aqaba (Dead Sea

transform fault). On 19 May 2009, 19 earthquakes of M4.0 or greater took place in the volcanic

area of Harrat Lunayyir to the north of Yanbu, including an M5.4 event that caused minor

damage to structures [4]. The 1995 Gulf of Aqaba earthquake (also known as Nuweiba

earthquake) occurred on November 22 at 06:15 local time (04:15 UTC) and registered 7.3 on the

moment magnitude scale. The epicenter was located in the central segment of the Gulf of Aqaba.

The earthquake occurred along the Dead Sea Transform (DST) fault system, an active tectonic

plate boundary with seismicity that is characterized by long-running quiescent periods with

occasional large and damaging earthquakes, along with intermittent earthquake swarms. It was

the strongest tectonic event in the area for many decades and caused injuries, damage, and deaths

throughout the Levant and is also thought to have remotely triggered a series of small to

moderate earthquakes 500 kilometers (310 miles) to the north of the epicenter. In the aftermath

of the quake, several field investigations set out to determine the extent of any surface faulting,

and the distribution of aftershocks was analyzed. Areas affected: Egypt, Israel, Jordan and Saudi

Arabia as shown in Figure 1[4]. Recent studies, historical evidence, geological and geophysical

observations indicate that parts of the Kingdom fall within seismic risk regions. In western Saudi

Arabia, a design peak ground acceleration (PGA) ranging from 0.03g to 0.26g for an economic

life of 50 years was suggested. Seismic zonation was established with zone numbers 0, 1, 2A,

and 2B [5]. Saudi Arabia is not free from earthquakes. It has experienced many earthquakes

during the recent history, and the previous studies in this field demonstrated this argument. Most

of the existing buildings in Saudi Arabia do not meet the current design standards due to design

shortage or construction shortcomings. Therefore, buildings should be designed regarding their

capacity for resisting the expected seismic effects. The seismic hazard analysis for the Kingdom

was performed [6,7]. Seismograph stations of the Saudi National Seismic Network as shown in

Figure 2 [8], was developed for the Kingdom based on the peak ground acceleration, PGA,

values calculated for 50 years service lifetime with 10% probability of being exceeded.

Page 3: Seismic Analysis and Design of a Multi-Storey Building ...€¦ · designed by using SBC 301 (2007) Saudi Building Code [1], SAP2000 (structural analysis software) [2] and ISACOL

M. Ismaeil et al./ Journal of Soft Computing in Civil Engineering 1-2 (2017) 35-51 37

Fig. 1. 1995 Gulf of Aqaba earthquake [4].

Fig. 2. Seismograph stations of the Saudi National Seismic Network [8].

2. Description and Model of the Building

A six-story residential building with plan and elevations as shown in Figures 3 to 6 is considered

for the study. The building is composed of moment resisting RC frame with solid slab, 140mm

thickness, situated in the most active seismic zone region of the Kingdom of Saudi Arabia. The

structure members are made of in-situ reinforced concrete. The overall plan of the building is

square with dimensions 14.5x15m as shown in Figure 3. The height of the building is 16 m, and

story height for each floor is 3.2 m. Columns and beams sizes are shown in Table 1. The building

is approximately symmetric in both directions. The plan and some frames of the studied building

as shown in Figures 3 to 5. Beams and columns have been modeled as frame elements while the

in-plane rigidity of the slab is simulated using rigid diaphragm action. The columns are assumed

to be fixed at the base. The building is analyzed.

As per seismic provisions provided by SBC 301-2007.

Page 4: Seismic Analysis and Design of a Multi-Storey Building ...€¦ · designed by using SBC 301 (2007) Saudi Building Code [1], SAP2000 (structural analysis software) [2] and ISACOL

38 M. Ismaeil et al./ Journal of Soft Computing in Civil Engineering 1-2 (2017) 35-51

Table 1

The cross-section of beams and columns.

Building Beams Level Columns Reinforcement

mm

mm

6 Stories 600*250 1st floor -2nd floor 600*250 12 Φ 16

(10 Φ 16) 3nd floor-4rd floor 500*250 10 Φ 16

5th floor 5th floor 450*250 10 Φ 16

Fig. 3. Architectural plan of the studied building.

Fig. 4. YZ elevation @ X=5.5 m of the studied building.

Page 5: Seismic Analysis and Design of a Multi-Storey Building ...€¦ · designed by using SBC 301 (2007) Saudi Building Code [1], SAP2000 (structural analysis software) [2] and ISACOL

M. Ismaeil et al./ Journal of Soft Computing in Civil Engineering 1-2 (2017) 35-51 39

Fig. 5. XZ elevation @ Y=9.5 m of the studied building.

Fig. 6. XY Plan of studied building.

3. Current Design

It is a common practice in The Kingdom of Saudi Arabia to design buildings without any

consideration of seismic loads. Therefore, the one typical case study has been studied first under

the effect of gravity loads and without consideration of seismic loads in order to check the

current design. Dead and live loads are following the equations and tables given in the SBC-301-

2007(Saudi Arabia) and second under the effect of seismic loads.

4. Modeling and Analysis of RC Residential Buildings due to Earthquake

Loads (Equivalent Static Method as per SBC-303-2007)

Most buildings and structures in the kingdom of Saudi Arabia have not yet been designed and

constructed in compliance with earthquake provisions or given any consideration for earthquake

effect.

Page 6: Seismic Analysis and Design of a Multi-Storey Building ...€¦ · designed by using SBC 301 (2007) Saudi Building Code [1], SAP2000 (structural analysis software) [2] and ISACOL

40 M. Ismaeil et al./ Journal of Soft Computing in Civil Engineering 1-2 (2017) 35-51

The horizontal seismic loads are defined according to Saudi Buildings Code (SBC-303-2007).

The lateral force effect on the structure can be translated to equivalent lateral force at the base of

the structure which can be distributed to different stories. According to Saudi Buildings Code

(SBC-303-2007), the total seismic base shear force V is determined as follows:

V = Cs*W )1(

Where: Cs is the seismic coefficient, W is the total weight and V is the base shear. The seismic

design coefficient (Cs) shall be determined by the following equation:

Cs = SDS / (R / I) )2(

Where SDS = Design spectral response acceleration in the short period range

R = Response modification factor

I = Occupancy importance factor determined

The value of the seismic response coefficient, (Cs), need not be greater than the following

equation:

Cs = SD1 / [T. (R / I)] )3(

However, shall not be taken less than:

T = 0.1N )4(

Where N = Number of stories

Cs = 0.044SDS I )5(

Where, SDS = Design spectral response acceleration at a period of 1 sec

T = Fundamental period of the structure (sec)

Design earthquake spectral response acceleration at short periods, SDS, and at the 1-sec period,

SD1, shall be as follows.

SMS= Fa*SS )6(

SM1= Fv*S1 )7(

SDS= 2/3*SMS )8(

SD1= 2/3*SM1 )9(

Where:

SS: the maximum spectral response acceleration at short periods

S1: the maximum spectral response acceleration at a period of 1 sec

Fa: acceleration-based site coefficient

Page 7: Seismic Analysis and Design of a Multi-Storey Building ...€¦ · designed by using SBC 301 (2007) Saudi Building Code [1], SAP2000 (structural analysis software) [2] and ISACOL

M. Ismaeil et al./ Journal of Soft Computing in Civil Engineering 1-2 (2017) 35-51 41

Fv: velocity-based site coefficient

SMS: the maximum spectral response acceleration at short periods adjusted for site class

SM1: the maximum spectral response acceleration at a period of 1 sec adjusted for site class

SDS: the design spectral response acceleration at short periods

SD1: the design spectral response acceleration at a period of 1 sec

5. Vertical Distribution of Base Force

The buildings are subjected to a lateral load distributed across the height of the buildings

based on the following formula specified by Saudi Buildings Code (SBC-303-2007):

Where Fx is the applied lateral force at level ‘x’, W is the story weight, h is the story height, and

V is the design base shear, and N is the number of stories. The summation in the denominator is

carried through all story levels. This results in an inverted triangular distribution when k is set

equal to unity. A uniform lateral load distribution consisting of forces that are proportional to the

story masses at each story level.

k = an exponent related to the structure period as follows:

For structures having a period of 0.5 sec or less, k = 1

For structures having a period of 2.5 sec or more, k= 2

6. LOAD COMBINATIONS AS PER SBC-303-2007

As per SBC-301 section 2.3, following load combinations should be considered for the design of

structures, components, and foundations.

1.4 (D + F)

1.2 (D + F + T) + 1.6 (L + H) + 0.5 (Lr or R)

1.2 D + 1.6 (Lr) + (f1L)

1.2D + f1L + 0.5 (Lr)

1.2D + 1.0 E + f1L

0.9D ± 1.0E

Where:

E = ρQE + 0.2SDSD

1.0 ≤ ρ ≤ 1.5

f1 = 1.0 for areas occupied as places of public assembly, for live loads more than 5.0 kN/m2,

and for parking garage live load.

Page 8: Seismic Analysis and Design of a Multi-Storey Building ...€¦ · designed by using SBC 301 (2007) Saudi Building Code [1], SAP2000 (structural analysis software) [2] and ISACOL

42 M. Ismaeil et al./ Journal of Soft Computing in Civil Engineering 1-2 (2017) 35-51

f1 = 0.5 for other live loads.

SDS = the design spectral response acceleration in the short period range as determined from

Section.

QE = the effect of horizontal seismic (earthquake-induced) forces.

Table 6.1 shows the design parameters taken from both codes for analysis of buildings.

7. Seismic Map for the Kingdom of Saudi Arabia

The Saudi Buildings Code (SBC-303-2007) provides seismic maps for the Kingdom of Saudi

Buildings, as shown in Figures 7 and 8.

Fig. 7. Maximum Considered Earthquake Ground Motion for the Kingdom of 1 SEC Spectral Response

Acceleration (S1 in %g) (5 Percent of Critical Damping), Site Class B. (Region 1) [1].

Fig. 8. Maximum Considered Earthquake Ground Motion for the Kingdom of 0.2 SEC Spectral Response

Acceleration (Ss in %g) (5 Percent of Critical Damping), Site Class B. (Region 1) [1].

Page 9: Seismic Analysis and Design of a Multi-Storey Building ...€¦ · designed by using SBC 301 (2007) Saudi Building Code [1], SAP2000 (structural analysis software) [2] and ISACOL

M. Ismaeil et al./ Journal of Soft Computing in Civil Engineering 1-2 (2017) 35-51 43

8. Mapped acceleration parameters

The design parameters that are used in the equivalent static method are illustrated as follows: The

parameters Ss and S1 shall be determined from the 0.2 and 1-second spectral response

accelerations shown on country maps

Where S1 is less than or equal to 0.04 and Ss is less than or equal 0.15, the structure is permitted

to be assigned to seismic design category A So,

S1= the mapped spectral accelerations for a 1- second period

Ss= the mapped spectral accelerations for a short period.

On lack of a map of spectral accelerations of S1 and SS, the following can be assumed:

S1= 1.25 Z, Ss= 2.5 Z (amendment no. 3 to SI 413 (2009)) or from maps as shown in

Figures 7 and 8.

9. The Results and Discussions

Figures 9 and 10 show the label of columns and beams of the selected frames.

Fig. 9. The label of beams and columns in direction XZ@Y=9.5 m.

Page 10: Seismic Analysis and Design of a Multi-Storey Building ...€¦ · designed by using SBC 301 (2007) Saudi Building Code [1], SAP2000 (structural analysis software) [2] and ISACOL

44 M. Ismaeil et al./ Journal of Soft Computing in Civil Engineering 1-2 (2017) 35-51

Fig. 10. The label of beams and columns in direction YZ@X= 5.5 m.

9.1. Results of analysis of considered buildings due to gravity loads

This part presents the results of analysis and design of considered RC buildings due to gravity

loads. We selected one frame in each direction X and Y as shown in figures 9 and 10 for columns

and beams.

1. Beams

Table 2 shows the Straining action of some beams in the selected frames at direction YZ @ X =

5.5

Table 2

The Straining action of some beams in the selected frames at direction YZ @ X = 5.5.

Direction Y-Z @ X=5.5

Load Case Ultimate (1.4DL+1.6LL)

Beam No. SHEAR MOMENT 3-3 (KN.m)

KN END START

B-03 -9.81 0.24 -6,81

B-09 21.7 -29.54 -1.62

B-11 -11.91 4.5 -10.15

B-17 21.42 -29.11 -1.61

B-19 -13.16 7.37 -12.3

Page 11: Seismic Analysis and Design of a Multi-Storey Building ...€¦ · designed by using SBC 301 (2007) Saudi Building Code [1], SAP2000 (structural analysis software) [2] and ISACOL

M. Ismaeil et al./ Journal of Soft Computing in Civil Engineering 1-2 (2017) 35-51 45

2. Columns

Tables 3 shows the Straining action of some columns in the selected frames at direction YZ @ X

= 5.5

Table 3

The Straining action of some columns in the selected frames at direction YZ @ X = 5.5.

Direction Y-Z @ X=5.5

Load Case Ultimate (1.4DL+1.6LL)

Column No. AXIAL SHEAR MOMENT 3-3 (KN.m)

KN END START

C-01 -907.8 -0.61 -0.62 -2.57

C-03 -1307.75 -10.94 21.51 -13.51

C-09 -586.33 0.56 -1.46 -0.33

C-11 -855.93 -15.98 26.44 -24.68

C-17 -285.18 0.63 -1.17 0.84

C-19 -421.77 -11.1 18.29 -17.22

9.2. Results of analysis of considered buildings due to seismic loads

This part presents the results of analysis and design of considered RC buildings due to seismic

loads. Using the Saudi Buildings Code (SBC-301-2007) provisions, the following parameters

have been calculated to be used as input data for seismic analysis of the selected model with

notice that the Haql City falls in region 6. The calculated results of these parameters are as

follows:

Table 4

The seismic parameter for Haql City according to SBC301.

SDS 0.14 CS = 0.0714

SD1 0.04 CS (max.) = 0.0678

I 1.00 CS(min.) = 0.0057

R 2.00

W= 812.0 KN V= 55.1 TON

Take CS= 0.678

Table 5

Calculation of Base Shear and lateral load distribution with height.

Story W (ton) h (m) w*h cv Fx (TON)

Sixth Floor 16.66 21 350 0.015 0.9

Fifth Floor 142.67 18 2568 0.114 6.3

Fourth Floor 268.69 15 4030 0.179 9.8

Third Floor 394.70 12 4736 0.210 11.6

Second Floor 520.72 9 4686 0.208 11.4

First Floor 646.73 6 3880 0.172 9.5

Ground Floor 772.75 3 2318 0.103 5.7

SUM(W*H) 22570 SUM FX 55.1

Page 12: Seismic Analysis and Design of a Multi-Storey Building ...€¦ · designed by using SBC 301 (2007) Saudi Building Code [1], SAP2000 (structural analysis software) [2] and ISACOL

46 M. Ismaeil et al./ Journal of Soft Computing in Civil Engineering 1-2 (2017) 35-51

1. Beams

Tables 6 shows the Straining action of some beams in the selected frames at direction YZ @ X =

5.5 m due to load case Group-Y

Table 6

The Straining action of some beams in the selected frames at direction YZ @ X = 5.5 m due to load case

Group-Y.

Direction Y-Z @ X=5.5 m

Load case: GroupY

Beam No. SHEAR MOMENT 3-3 (KN.m)

KN END START

B-03 53.39 -93.73 90.13

B-09 22.07 -30.12 -1.65

B-11 49.02 -86.03 82.88

B-17 21.78 -29.68 -1.64

B-19 32.05 -52.51 49.84

Where:

Load Case Group-Y is load combination included seismic loads at Y direction.

Load Case Ultimate is load combination included dead and live loads only

2. Columns

Tables 7 shows the Straining action of some columns in the selected frames at direction YZ @ X

= 5.5 m

Table 7

The Straining action of some Columns in the selected frames at direction YZ @ X = 5.5 m due to load

case Group-Y.

Direction Y-Z @ X=5.5

Load Case: GroupY

Column No. AXIAL SHEAR MOMENT 3-3 (KN.m)

KN END START

C-01 -922.95 1.23 -2.68 -2.62

C-03 -1331.32 -11.18 21.93 -13.8

C-09 -596.12 1.74 -3.28 2.3

C-11 -871.43 -18.32 27.01 -25.21

C-17 -289.96 0.74 -1.33 1.04

C-19 -429.44 -11.33 18.68 -17.59

10. Design of structural elements against gravity loads

The reinforced concrete sections were designed according to the BSI 8110 [9] using the limit

state design method (Mosley and Bungey, 1997) [10].

Page 13: Seismic Analysis and Design of a Multi-Storey Building ...€¦ · designed by using SBC 301 (2007) Saudi Building Code [1], SAP2000 (structural analysis software) [2] and ISACOL

M. Ismaeil et al./ Journal of Soft Computing in Civil Engineering 1-2 (2017) 35-51 47

10.1. Design of columns

(a) Calculation of internal forces in columns

The columns were designed to resist axial compression forces and bending moment due to

gravity load. The design forces in columns obtained from the computer analysis program

SAP2000 are shown in Table 8.

*Direction YZ@X=5.5

Table 8

Internal forces in columns due to gravity loads.

Column No. Output Case Shear Force (KN) Bending Moment (KN.m) Axial Force (KN)

C04 1.4DL+1.6LL 11.26 13.99 1372.02

C03 1.4DL+1.6LL 10.94 13.51 1307.75

C02 1.4DL+1.6LL 1.64 3.78 997.52

C01 1.4DL+1.6LL -0.61 2.57 907.80

(b) Design of columns before adding seismic loads

* Direction YX@X=5.5

The design of columns has been performed using a computer program called ISACOL [5].

Figures 11 and 13 show the main window of ISACOL program and sample of column design.

Fig. 11. ISACOL program results for C40 [3].

Page 14: Seismic Analysis and Design of a Multi-Storey Building ...€¦ · designed by using SBC 301 (2007) Saudi Building Code [1], SAP2000 (structural analysis software) [2] and ISACOL

48 M. Ismaeil et al./ Journal of Soft Computing in Civil Engineering 1-2 (2017) 35-51

Table 9

Design of columns before adding seismic Loads.

Column No. Original design Present design

Dimensions Reinforcement Dimensions Reinforcement

C04 250 X 500 12 Φ 16 250 X 500 10 Φ 16

C03 250 X 500 12 Φ 16 250 X 500 10 Φ 16

C02 250 X 500 12 Φ 16 250 X 500 10 Φ 16

C01 250 X 500 12 Φ 16 250 X 500 10 Φ 16

250*500 250*500

12 Φ 16 10 Φ 16

Fig. 12. Design of some columns before adding seismic Loads.

10.2. Design of beams

As for the beams, the internal forces due to gravity loads have been calculated first. Then the BSI

[9], has been used to check the existing design. It has been found that the existing design is

adequate.

11. Design of structural elements against gravity loads and earthquake loads

The reinforced concrete sections were designed according to the BSI 8110 [9] using the limit

state design method (Mosley and Bungey, 1997) [10].

11.1. Design of columns

(a) Calculation of internal forces in columns

The columns were designed to resist seismic and gravity load. The design forces in columns

obtained from the computer analysis program SAP2000 are shown in Table 10.

* Direction YZ@X=5.5 m

Table 10

Internal forces in columns due to seismic loads.

Column No. Output Case Shear Force (KN) Bending Moment (KN.m) Axial Force (KN)

C04 GROUPX 159.27 298.95 1397.14

C03 GROUPX 137.69 256.36 1331.32

C02 GROUPX 125.60 223.55 1041.80

C01 GROUPX 96.96 173.70 922.95

Page 15: Seismic Analysis and Design of a Multi-Storey Building ...€¦ · designed by using SBC 301 (2007) Saudi Building Code [1], SAP2000 (structural analysis software) [2] and ISACOL

M. Ismaeil et al./ Journal of Soft Computing in Civil Engineering 1-2 (2017) 35-51 49

(b) Design of columns after adding seismic loads

The design of columns has been performed using a computer program called ISACOL [3].

Figures 12 and 14 show the design of some columns before and after adding seismic loads.

Fig. 13. ISACOL program results for C04 [3].

Table 11. Shows the design of columns after adding seismic loads.

Table 11

Design of columns after adding seismic loads-direction (y).

Column No. Original design Including seismic loads

Dimensions Reinforcement Dimensions Reinforcement

C04 250 X 500 10 Φ 16 250*1550 18 Φ 20

C03 250 X 500 10 Φ 16 250*1250 14 Φ 20

C02 250 X 500 10 Φ 16 250*1200 14 Φ 20

C01 250 X 500 10 Φ 16 250*850 12 Φ 20

250*1200 250*850

14 Φ 20 12 Φ 20

Fig.14. Design of some columns after adding seismic loads

Page 16: Seismic Analysis and Design of a Multi-Storey Building ...€¦ · designed by using SBC 301 (2007) Saudi Building Code [1], SAP2000 (structural analysis software) [2] and ISACOL

50 M. Ismaeil et al./ Journal of Soft Computing in Civil Engineering 1-2 (2017) 35-51

12. Conclusion

This paper provides a set of seismic analysis and design of RC buildings located in the most

active seismic zone region in Saudi Arabia. The building was analyzed and designed before and

after considering earthquake loads applied in two directions; XX and YY. From the results

obtained it can be seen that:

1. There are slight changes in the values of the bending moments and shear forces on the beams

before and after considering earthquake loads as shown in Tables 2 and 6. There is an increase in

some internal beams, such as B-3, B-11, and B-19.

2. The values of the bending moments and shear forces on the columns due to seismic loads are

nearly five times that due to gravity loads as shown in Tables 8 and 10.

3. The values of the axial forces on the columns due to seismic loads are approximately similar

to gravity loads as shown in Tables 8 and 10.

4. As an overall trend the results showed that the current design of RC buildings located in the

most active seismic zone region of the Kingdom of Saudi Arabia, Haql city were found unsafe,

inadequate and unsatisfied to mitigate seismic loads.

The present study represents the first attempt to investigate the seismic resistance of residual

buildings in Haql city in Saudi Arabia. Due to the lack of knowledge about the seismic activity in

this country some buildings are designed and constructed without any seismic load

consideration. Seismicity of Saudi Arabia may be considered as moderate. Hence, all buildings

should be checked against earthquake resistance. The present paper proposes a simple procedure

to check the seismic resistance of such buildings.

The obtained results emphasize the following conclusions:

1- Current design of some residual buildings in Saudi Arabia does not consider earthquake loads.

2- It has been found that the current design of residual buildings in the Haql city is unsafe for the

current seismicity of the Haql city.

Acknowledgments

The author would like to express his gratitude to King Khalid University, Saudi Arabia for

providing administrative and technical support.

References

[1] Saudi Building Code SBC-301-2007: Loads and Forces Requirements, Saudi Buildings Code

National Committee. 2007.

[2] Wilson EL. Three-dimensional static and dynamic analysis of structures. Computers and Structures

Inc., Berkeley, California, U.S.A: Computers and structures; 2002.

Page 17: Seismic Analysis and Design of a Multi-Storey Building ...€¦ · designed by using SBC 301 (2007) Saudi Building Code [1], SAP2000 (structural analysis software) [2] and ISACOL

M. Ismaeil et al./ Journal of Soft Computing in Civil Engineering 1-2 (2017) 35-51 51

[3] Shehata AY. Information Systems Application on Reinforced Concrete Columns. M. Sc. Thesis,

Faculty of Engineering, Department of Structural Engineering, Cairo University, Giza, Egypt,

1999.

[4] https://en.wikipedia.org/wiki/1995_Gulf_of_Aqaba_earthquake n.d.

[5] Attar MS. Evaluation of the Seismic Performance of A Typical School Building. Master Thesis,

College of Engineering, KAAU, 2003.

[6] Al-Haddad M, Siddiqi GS, Al-Zaid R, Arafah A, Necioglu A, Turkelli N. A Study Leading to a

Preliminary Seismic Design Criteria, for the Kingdom. Final Report, KACST Proj No AR-9-31,

Riyadh 1992.

[7] Al-Haddad M, Siddiqi GH, Al-Zaid R, Arafah A, Necioglu A, Turkelli N. A basis for evaluation of

seismic hazard and design criteria for Saudi Arabia. Earthq Spectra 1994;10:231–58.

[8] Hassaballa AE, Adam FM, Ismaeil MA. Seismic Analysis of a Ten-Storey Reinforced Concrete

Building in Jazan Area, KSA. Open J Civ Eng 2017;07:252–66. doi:10.4236/ojce.2017.72016.

[9] BS8110. Structural Use of Concrete,. British Standard Institution, London: 1997.

[10] Mosley WH, Bungey JH. Reinforced Concrete Design; BS 8110:Part 1, 2nd Ed. Macmillan ,

London: 1997.