2
Intelligent, Robust yet Simple to Install and Use With the number and complexity of POC instruments increasing you need a solution that can address any of them yet keep routine oper- ation uniform and simple. The SNI- POC provides the power to control communication with any remote POC device, serving the serial protocol close to the analyzer and handling any required front end processing. We hard code most of the configuration for use with a specific analyzer to minimize onsite setup requirements. This simplifies the configuration process, as users only need to deal with a single configuration screen. POC connectivity - a complex problem Connection of POC instrumen- tation to an LIS is a two-step problem: 1. The need to establish reliable connection of the remote instru- ments to a central POC Data Management System. 2. Provide connectivity of the Data Management System to the Lab Information System. Historically, these problems have been addressed by connecting POC instruments to the central DMS using terminal servers or modems. As hospitals upgrade their IT infrastructure, direct net- work connectivity is available, and is the preferred method of connecting remote instruments. The new SNI-POC is designed to leverage this technology and provide superior connections at a lower cost. * POC connectivity - a complex problem solved! The SNI-POC from Dawning Technologies quickly and easily solves your connectivity problems thanks to its high-level design and our expertise in providing "Smart Connections" to over 2000 clients worldwide. The Distributed pro- cessing Advantage The SNI-POC provides a dedicated CPU to each remote instrument connection allowing local process- ing of instrument data records, removing substantial processing demand from the central DMS, improving overall efficiency. By automatically delivering data files to the DMS using an FTP based protocol as opposed to terminal servers, which merely packetize serial data streams, the SNI-POC can decrease network traffic and enhance system reliability. Dawning Technologies, Inc. 800-332-0499 716-223-6006 www.dawning.com ©Dawning Technologies, Inc. 2001 7/01 T he Point of Care version Secure Network Interface has been exclusively designed to support a wide spectrum of OEM applications. This solution connects remote POC instruments to a central POC data management system, via the enterprise network, eliminating the need for additional connection hardware such as terminal servers. This innovative design adds processing power and intelligence at the instrument level enabling local service of the instruments' serial communication protocol, instead of from a remote location on the network. An OEM Connectivity Solution from Dawning Technologies, Inc. Secure Network Interface Secure Network Interface - Point of Care Version

Secure Network Interface Secure Network Interface - - Apollo

  • Upload
    others

  • View
    18

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Secure Network Interface Secure Network Interface - - Apollo

Intelligent, Robust yet Simple to Install and UseWith the number and complexityof POC instruments increasing youneed a solution that can addressany of them yet keep routine oper-ation uniform and simple. The SNI-POC provides the power to controlcommunication with any remotePOC device, serving the serialprotocol close to the analyzer andhandling any required front endprocessing. We hard code mostof the configuration for use witha specific analyzer to minimizeonsite setup requirements. Thissimplifies the configurationprocess, as users only need todeal with a single configurationscreen.

POC connectivity - a complex problemConnection of POC instrumen-tation to an LIS is a two-stepproblem:

1. The need to establish reliableconnection of the remote instru-ments to a central POC DataManagement System.

2. Provide connectivity of theData Management System to theLab Information System.

Historically, these problems havebeen addressed by connectingPOC instruments to the centralDMS using terminal servers ormodems. As hospitals upgradetheir IT infrastructure, direct net-work connectivity is available,and is the preferred method ofconnecting remote instruments.The new SNI-POC is designedto leverage this technology andprovide superior connections ata lower cost. *

POC connectivity - a complex problemsolved!The SNI-POC from DawningTechnologies quickly and easilysolves your connectivity problemsthanks to its high-level design andour expertise in providing "SmartConnections" to over 2000 clientsworldwide.

The Distributed pro-cessing AdvantageThe SNI-POC provides a dedicatedCPU to each remote instrumentconnection allowing local process-ing of instrument data records,removing substantial processingdemand from the central DMS,improving overall efficiency. Byautomatically delivering data filesto the DMS using an FTP basedprotocol as opposed to terminalservers, which merely packetizeserial data streams, the SNI-POCcan decrease network traffic andenhance system reliability.

������������

Dawning Technologies, Inc. 800-332-0499 • 716-223-6006

www.dawning.com

©Dawning Technologies, Inc. 20017/01

The Point of Care version Secure Network Interface has been exclusively designed to support a widespectrum of OEM applications. This solution connects remote POC instruments to a central POC datamanagement system, via the enterprise network, eliminating the need for additional connection hardwaresuch as terminal servers. This innovative design adds processing power and intelligence at the instrumentlevel enabling local service of the instruments' serial communication protocol, instead of from a remotelocation on the network.

An OEM Connectivity Solutionfrom Dawning Technologies, Inc.

Secure NetworkInterfaceSecure NetworkInterface -Point of CareVersion

Page 2: Secure Network Interface Secure Network Interface - - Apollo

Secure Network Interface

Point of Care Version

������������

Dawning Technologies, Inc. • 800-332-0499 • 716-223-6006 • www.dawning.com ©Dawning Technologies, Inc. 2001 7/01

The intent is to allow instrument field service per-sonnel or customers to install the SNI-POC withno assistance. The units can be flash updatedfrom a remote workstation at any time to handlereconfiguration. Dawning's experienced program-ming staff can provide a configuration for anyinstrument you require.

Fixed IP or DHCP environmentThe new SNI-POC can operate either with a fixedIP address or in a DHCP environment, at the pref-erence of the customer. The addition of a smallsoftware utility on the DMS end allows communi-cation via DHCP.

Browser interactionThe SNI-POC like the original Secure NetworkInterface is a web-enabled device that providesaccess to configuration and diagnostic featuresvia a standard web browser from any authorizedremote workstation.

More than an InterfaceCapable of much more than its basic function ofcapturing all appropriate result data records pro-duced by the instrument and delivering them tothe POC DMS; the SNI-POC offers the option ofimplementing advanced functionality such asbi-directional communication with the analyzer tohandle instrument diagnostic, usage and mainte-nance information, which offers a more robust andcompetitive POC solution.

Small footprint - Small costThe SNI-POC is less than 6" square, providing allthe functionality typically found in a PC basedinterface in the space of a mini-hub - and at aprice comparable to single port terminal servers.

Embedded connectivity solutionsWith 15 years demonstrated expertise in hardware, software,network and Web based development; Dawning Technologiescan design a configuration of the SNI-POC (or other products)to fit within the frame of a new or existing instrument. Such anembedded solution would provide all the above-described capabilityat lower cost, presenting an intelligent network port to the outsideworld. Contact Dawning at 1-800-332-0499, or [email protected] determine how this might be accomplished for your instrumenta-tion projects.

Pricing:

Secure Network Interface, Point of Care version

Part Number: E0327• Price : . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . $400 US

SNI - POC REARVIEW

*Dawning does not offer a central POC data management sys-tem. The SNI-POC is intended for OEM manufacturers of thesePOC DMS systems, offering a superior connectivity alternative.

��������

��� ���

���

�����������

������

����������

�������������

����������

���������� !�����"���

����������� �����#

��$�%��#�������&$�

' ����������(

���������������

��������

��������

����������

)

������