26
1 www.aqualitec.com www.aqualitec.com SCREENTEC, THE PUMP STATION BAR SCREEN

Screentec, Pump Station Bar Screen - Aqualitecaqualitec.com/pdf/Screentec_EpcorWater_2013.pdf · 2015. 4. 27. · SCREENTEC, THE PUMP STATION BAR SCREEN SPACE REQUIREMENTS - FOOTPRINT

  • Upload
    others

  • View
    4

  • Download
    4

Embed Size (px)

Citation preview

Page 1: Screentec, Pump Station Bar Screen - Aqualitecaqualitec.com/pdf/Screentec_EpcorWater_2013.pdf · 2015. 4. 27. · SCREENTEC, THE PUMP STATION BAR SCREEN SPACE REQUIREMENTS - FOOTPRINT

1 www.aqualitec.com www.aqualitec.com

SCREENTEC, THE PUMP STATION BAR SCREEN

Page 2: Screentec, Pump Station Bar Screen - Aqualitecaqualitec.com/pdf/Screentec_EpcorWater_2013.pdf · 2015. 4. 27. · SCREENTEC, THE PUMP STATION BAR SCREEN SPACE REQUIREMENTS - FOOTPRINT

2 www.aqualitec.com www.aqualitec.com

SCREENTEC, THE PUMP STATION BAR SCREEN

Sun City Pump Station, AZ – Epcor Water

Scope of Work

Solution

Installation of Screentec

Conclusion

Page 3: Screentec, Pump Station Bar Screen - Aqualitecaqualitec.com/pdf/Screentec_EpcorWater_2013.pdf · 2015. 4. 27. · SCREENTEC, THE PUMP STATION BAR SCREEN SPACE REQUIREMENTS - FOOTPRINT

3 www.aqualitec.com

Scope of Work

Install a mechanical bar screen in a lift station

www.aqualitec.com

SCREENTEC, THE PUMP STATION BAR SCREEN

Page 4: Screentec, Pump Station Bar Screen - Aqualitecaqualitec.com/pdf/Screentec_EpcorWater_2013.pdf · 2015. 4. 27. · SCREENTEC, THE PUMP STATION BAR SCREEN SPACE REQUIREMENTS - FOOTPRINT

4 www.aqualitec.com

Scope of work

www.aqualitec.com

SCREENTEC, THE PUMP STATION BAR SCREEN

SPACE REQUIREMENTS - FOOTPRINT

Depth: 23’ – 7’’

Channel Width: 3’ – 3”

Equipment Width: 3’ –28"

Height of discharge: 3 – 11 (1200 mm)

Installation angle: 90°

Weight: 1430 lbs (650 kg)

HYDRAULIC CONDITIONS

Influent: Raw Municipal

Peak flow: 2.5mgd

Maximum Design flow: 5.1mgd

Page 5: Screentec, Pump Station Bar Screen - Aqualitecaqualitec.com/pdf/Screentec_EpcorWater_2013.pdf · 2015. 4. 27. · SCREENTEC, THE PUMP STATION BAR SCREEN SPACE REQUIREMENTS - FOOTPRINT

5 www.aqualitec.com

Scope of work

Retrofit with minimal structural changes

www.aqualitec.com

SCREENTEC, THE PUMP STATION BAR SCREEN

Page 6: Screentec, Pump Station Bar Screen - Aqualitecaqualitec.com/pdf/Screentec_EpcorWater_2013.pdf · 2015. 4. 27. · SCREENTEC, THE PUMP STATION BAR SCREEN SPACE REQUIREMENTS - FOOTPRINT

6 www.aqualitec.com

Scope of work

Retrofit with minimal structural changes

www.aqualitec.com

SCREENTEC, THE PUMP STATION BAR SCREEN

Page 7: Screentec, Pump Station Bar Screen - Aqualitecaqualitec.com/pdf/Screentec_EpcorWater_2013.pdf · 2015. 4. 27. · SCREENTEC, THE PUMP STATION BAR SCREEN SPACE REQUIREMENTS - FOOTPRINT

7 www.aqualitec.com

Scope of work

No more manual and unsafe maintenance

www.aqualitec.com

SCREENTEC, THE PUMP STATION BAR SCREEN

Page 8: Screentec, Pump Station Bar Screen - Aqualitecaqualitec.com/pdf/Screentec_EpcorWater_2013.pdf · 2015. 4. 27. · SCREENTEC, THE PUMP STATION BAR SCREEN SPACE REQUIREMENTS - FOOTPRINT

8 www.aqualitec.com

Scope of work

Protects pumps from debris

www.aqualitec.com

SCREENTEC, THE PUMP STATION BAR SCREEN

Page 9: Screentec, Pump Station Bar Screen - Aqualitecaqualitec.com/pdf/Screentec_EpcorWater_2013.pdf · 2015. 4. 27. · SCREENTEC, THE PUMP STATION BAR SCREEN SPACE REQUIREMENTS - FOOTPRINT

9 www.aqualitec.com www.aqualitec.com

SCREENTEC, THE PUMP STATION BAR SCREEN

Sun City Pump Station, AZ – Epcor Water

Scope of Work

Solution

Installation of Screentec

Conclusion

Page 10: Screentec, Pump Station Bar Screen - Aqualitecaqualitec.com/pdf/Screentec_EpcorWater_2013.pdf · 2015. 4. 27. · SCREENTEC, THE PUMP STATION BAR SCREEN SPACE REQUIREMENTS - FOOTPRINT

10 www.aqualitec.com

Screentec Solution

www.aqualitec.com

SCREENTEC, THE PUMP STATION BAR SCREEN

Page 11: Screentec, Pump Station Bar Screen - Aqualitecaqualitec.com/pdf/Screentec_EpcorWater_2013.pdf · 2015. 4. 27. · SCREENTEC, THE PUMP STATION BAR SCREEN SPACE REQUIREMENTS - FOOTPRINT

11 www.aqualitec.com

Screentec Solution

Screentec, Bar Screen Solution

Vertical design

Retrofit any structure

No moving part under grade level

Integrated bypass

Washer Compactor

Gas extraction

www.aqualitec.com

SCREENTEC, THE PUMP STATION BAR SCREEN

Page 12: Screentec, Pump Station Bar Screen - Aqualitecaqualitec.com/pdf/Screentec_EpcorWater_2013.pdf · 2015. 4. 27. · SCREENTEC, THE PUMP STATION BAR SCREEN SPACE REQUIREMENTS - FOOTPRINT

12 www.aqualitec.com www.aqualitec.com

SCREENTEC, THE PUMP STATION BAR SCREEN

Sun City Pump Station, AZ – Epcor Water

Scope of Work

Solution

Installation of Screentec

Conclusion

Page 13: Screentec, Pump Station Bar Screen - Aqualitecaqualitec.com/pdf/Screentec_EpcorWater_2013.pdf · 2015. 4. 27. · SCREENTEC, THE PUMP STATION BAR SCREEN SPACE REQUIREMENTS - FOOTPRINT

Installation of Screentec

13 www.aqualitec.com www.aqualitec.com

SCREENTEC, THE PUMP STATION BAR SCREEN

Page 14: Screentec, Pump Station Bar Screen - Aqualitecaqualitec.com/pdf/Screentec_EpcorWater_2013.pdf · 2015. 4. 27. · SCREENTEC, THE PUMP STATION BAR SCREEN SPACE REQUIREMENTS - FOOTPRINT

Installation of Screentec

14 www.aqualitec.com www.aqualitec.com

SCREENTEC, THE PUMP STATION BAR SCREEN

Page 15: Screentec, Pump Station Bar Screen - Aqualitecaqualitec.com/pdf/Screentec_EpcorWater_2013.pdf · 2015. 4. 27. · SCREENTEC, THE PUMP STATION BAR SCREEN SPACE REQUIREMENTS - FOOTPRINT

Installation of Screentec

15 www.aqualitec.com www.aqualitec.com

SCREENTEC, THE PUMP STATION BAR SCREEN

Page 16: Screentec, Pump Station Bar Screen - Aqualitecaqualitec.com/pdf/Screentec_EpcorWater_2013.pdf · 2015. 4. 27. · SCREENTEC, THE PUMP STATION BAR SCREEN SPACE REQUIREMENTS - FOOTPRINT

Installation of Screentec

16 www.aqualitec.com www.aqualitec.com

SCREENTEC, THE PUMP STATION BAR SCREEN

Page 17: Screentec, Pump Station Bar Screen - Aqualitecaqualitec.com/pdf/Screentec_EpcorWater_2013.pdf · 2015. 4. 27. · SCREENTEC, THE PUMP STATION BAR SCREEN SPACE REQUIREMENTS - FOOTPRINT

Installation of Screentec

17 www.aqualitec.com www.aqualitec.com

SCREENTEC, THE PUMP STATION BAR SCREEN

Page 18: Screentec, Pump Station Bar Screen - Aqualitecaqualitec.com/pdf/Screentec_EpcorWater_2013.pdf · 2015. 4. 27. · SCREENTEC, THE PUMP STATION BAR SCREEN SPACE REQUIREMENTS - FOOTPRINT

Installation of the Screentec

18 www.aqualitec.com www.aqualitec.com

SCREENTEC, THE PUMP STATION BAR SCREEN

Page 19: Screentec, Pump Station Bar Screen - Aqualitecaqualitec.com/pdf/Screentec_EpcorWater_2013.pdf · 2015. 4. 27. · SCREENTEC, THE PUMP STATION BAR SCREEN SPACE REQUIREMENTS - FOOTPRINT

Installation of Screentec

19 www.aqualitec.com

Current

www.aqualitec.com

SCREENTEC, THE PUMP STATION BAR SCREEN

Page 20: Screentec, Pump Station Bar Screen - Aqualitecaqualitec.com/pdf/Screentec_EpcorWater_2013.pdf · 2015. 4. 27. · SCREENTEC, THE PUMP STATION BAR SCREEN SPACE REQUIREMENTS - FOOTPRINT

Installation of Screentec

20 www.aqualitec.com www.aqualitec.com

SCREENTEC, THE PUMP STATION BAR SCREEN

Page 21: Screentec, Pump Station Bar Screen - Aqualitecaqualitec.com/pdf/Screentec_EpcorWater_2013.pdf · 2015. 4. 27. · SCREENTEC, THE PUMP STATION BAR SCREEN SPACE REQUIREMENTS - FOOTPRINT

Installation of Screentec

21 www.aqualitec.com

Previous

Current

www.aqualitec.com

SCREENTEC, THE PUMP STATION BAR SCREEN

Page 22: Screentec, Pump Station Bar Screen - Aqualitecaqualitec.com/pdf/Screentec_EpcorWater_2013.pdf · 2015. 4. 27. · SCREENTEC, THE PUMP STATION BAR SCREEN SPACE REQUIREMENTS - FOOTPRINT

22 www.aqualitec.com www.aqualitec.com

SCREENTEC, THE PUMP STATION BAR SCREEN

Screentec collect debris (including rags,wipes, grit…)

Page 23: Screentec, Pump Station Bar Screen - Aqualitecaqualitec.com/pdf/Screentec_EpcorWater_2013.pdf · 2015. 4. 27. · SCREENTEC, THE PUMP STATION BAR SCREEN SPACE REQUIREMENTS - FOOTPRINT

23

WASTEWATER TREATMENT EQUIPENT

www.aqualitec.com

Significant savings with a small investment

SCREENTEC, THE PUMP STATION BAR SCREEN

Manual labor Mechanical operation

Unsafe environment (H2S) No below-grade maintenance

Structural constraints No structural changes

Page 24: Screentec, Pump Station Bar Screen - Aqualitecaqualitec.com/pdf/Screentec_EpcorWater_2013.pdf · 2015. 4. 27. · SCREENTEC, THE PUMP STATION BAR SCREEN SPACE REQUIREMENTS - FOOTPRINT

24 www.aqualitec.com www.aqualitec.com

SCREENTEC, THE PUMP STATION BAR SCREEN

Sun City Pump Station, AZ – Epcor Water

Scope of Work

Solution

Installation of Screentec

Conclusion

Page 25: Screentec, Pump Station Bar Screen - Aqualitecaqualitec.com/pdf/Screentec_EpcorWater_2013.pdf · 2015. 4. 27. · SCREENTEC, THE PUMP STATION BAR SCREEN SPACE REQUIREMENTS - FOOTPRINT

25 www.aqualitec.com

Screentec allows wastewater operators to protect expensive

pump equipment from non-dispersible debris.

Screentec’s versatile design fits almost any application with

minimal retrofit.

Screentec’s automatic operation frees operators from costly

and dangerous manual maintenance.

Screentec’s simple, versatile design makes it

affordable, effective, and reliable.

Keep It Simple.

www.aqualitec.com

SCREENTEC, THE PUMP STATION BAR SCREEN

Page 26: Screentec, Pump Station Bar Screen - Aqualitecaqualitec.com/pdf/Screentec_EpcorWater_2013.pdf · 2015. 4. 27. · SCREENTEC, THE PUMP STATION BAR SCREEN SPACE REQUIREMENTS - FOOTPRINT

Erwan Ouattara (310) 926-3118

[email protected]

Olivier Monfort (310) 703-2174

[email protected]

26 www.aqualitec.com

Keep It Simple.

www.aqualitec.com

SCREENTEC, THE PUMP STATION BAR SCREEN

Contact Information