SANYO Air Conditioners & Heat PumpsBtu/h 9,000 12,000 18,000 24,000 26,000 30,000 36,000 42,000
AIRCONDITIONER
WallMounted
CeilingSuspended
CeilingRecessed
ConcealedDuct
KS0971 KS1271 KS1872
MODEL (System)
Type Standard Low Ambient
KS2472 KHS2672R
MODEL (System)
THW3672R THW4272R
XHW3672R XHW4272R
UHW3672R
WallMounted
CeilingSuspended
HEATPUMPWITHHEATER
Outdoor
Outdoor
Outdoor
KHS3672R
KS3682
KHS3072R
KS3082
THW2672R
XHW3672R
UHW2672R UHW3672R
XHW4272R
ConcealedDuct
CeilingRecessed
CeilingSuspended
WallMounted
HEATPUMPWITHOUTHEAT
ER
KHS0971 KHS1271 KHS1872 KHS2472
MODEL (System) 09KHS7112KHS7112XHS71
18KHS7218XHS72
24KHS7226KHS72R 26THW72R26XHW72R 26UHW72R
36KHS72R 36THW72R36XHW72R6UHW72R
36KHS82
42THW72R42XHW72R
30KHS72R30KHS82
C0971 CL0971 C1872 CL1872 C2472 CL2472 C3072R / C3082C2672R C3672R / C3682 C4272R
THW4272RTHW3672R
THW2672R
XHW2672R
UHW2672R
CH0971 CH1271 CH1872 CH2472CH3072RCH3082
KHHS2672R
26KHHS72R26THHW72R
36THHW72R
THHW3672RTHHW2672R
CH2672R
09KS71 09KLS71 12KS71 12KLS7112XS71 12XLS71
18KS72 18KLS7218XS72 18XLS72
24KS72 24KLS72 30KS72R30KS82
36KS72R 36TW72R36XW72R 36UW72R
36KS82
42TW72R42XW72R
Standard Low Ambient Standard Low Ambient Standard Low Ambient Low Ambient Low Ambient Low Ambient Low Ambient
CH3672R
CH3672RCH3682CH2672R
XHW2672R
C1271 CL1271
KHS3672R
KHS3682
KHS3072R
KHS3082KHS2672R
CH4272R
26KS72R 26TW72R26XW72R 26UW72R
XS1271 XS1872
XHS1271 XHS1872
8/7/2019 Sanyo HVAC Catalog
3/28
3
18 K H S 7 2Voltage: 1:115V
2: 208/230VCooling Capacity in BTU/h
M: Muliti-Zone
ModelSeries No.
S: Wireless remote ControlW: Wired remote Control
H: Heater
Function
H: HeatPump
L: Low Ambient
Indoor Unit Type
K: Wall Mounted
T: Ceiling Suspended
X: 4way Ceiling Recessed
U: ConceiledDuct
K H S187 2Voltage: 1:115V
2: 208/230V
M: Muliti-Zone
ModelSeries No.
Cooling Capacity in BTU/h
FunctionH: Heat Pump
Indoor Unit Type
K: Wall Mounted
T: Ceiling Suspended
X: 4way Ceiling Recessed
U: ConceiledDuct
C: Outdoorunit
S: Wireless remote ControlW:Wiredremote ControlH: Heater
Model Identification
System
Flexi Multi Inverter
Component
l
li i i
l i i -
l i
i
L L i
I i
ll
ili
ili
il
18KHS72Master model No.
(System)
CH1872Outdoor unit
KHS1872Indoor unit
+
Standard Standard Standard Standard Standard
WallMounted
CeilingRecessed
KMS0772
XMS0972
KMS0972
XMS1272
KMS1272 KMS1872
XS1872
KMS2472
Btu/h 7,000 9,000 12,000 18,000 24,000
WallMounted
CeilingRecessed
Standard
Outdoor
Standard Standard
CM1972A CM2472A CM3172A
Btu/h 19,000 24,000 31,000
Outdoor
CMH1972A CMH2472A CMH3172A
KMHS0772 KMHS0972
XMHS0972
KMHS1272
XMHS1272
KMHS1872
XHS1872
KMHS2472
Type
Btu/h 19,000 24,000 31,000
AIRCONDITIONER
Type
Btu/h 7,000 9,000 12,000 18,000 24,000
HEATPUM
P
Up to 3Rooms
Up to 4Rooms
Up to 4Rooms
Up to 3Rooms
Up to4Rooms
Up to 4Rooms
CONTENSANYO L
Feature C
Features
Remote COptions
Benefits
Wall-Mo 09KS71/ 12KS71/ 18KS72/ 24KS72/ 26KS72R 30KS72R 36KS72R 36KS72R 30KS82 36KS82
Wall-Mo 09KHS7 12KHS7 18KHS7 24KHS7 26KHHS 26KHS72 30KHS7
36KHS7 30KHS8 36KHS8
p
Flexi Mu 19000 B 24000 B 31000 B
Flexi-MuCombinat
Cooling
Heating
Ceiling S
26TW72 26THW7 36TW72 42TW72 36THW7 42THW7 26THHW 36THHW
Ceiling R 12XS71 12XLS7 12XHS7 18XS72 18XLS72 18XHS7 26XW72 36XW72 42XW72
26XHW7 36XHW7 42XHW7
Conceale 26UW72 36UW72 26UHW 36UHW
System OAccessor
Operation
8/7/2019 Sanyo HVAC Catalog
4/28
G
4
CeilingSuspended
MODEL FEATURE CHART OP: Option
OP
G
OP
G
G G G G G G G
GG
G
---
G
G
OP
OP
OP
G
--G
G
G
G
G
OP
G
G
--
--
--
- -- -
26UW72R36UW72R
G G
G G
G G
G G
G -
G -- -- -
- -G G
OP OP
- -G G
OP OP
G -G G
G G
OP OP
G G
G G
G G
09KS7112KS7118KS7224KS72
12XS7118XS72
G G G G G
09KLS7112KLS7118KLS7224KLS7230KS8236KS82
G
26KS72R
12XLS7118XLS72
30KS72R36KS72R
26TW72R36TW72R42TW72R
26XW72R36XW72R42XW72R
G G
G G
-- -
OP
GGG
ODP=0Refrigerant
ElectricExpansion Valve
Low AmbientOperation
Built-In DrainPump
BranchExtension
Fresh Air Intake
Automatic RestartFunction afterPower Failure
Filter Sign
Anti-Mold Filter
SystemController
Weekly Timer
1-Hour OFFTimer
72-HourON/OFF Timer
24-Hour Clockwith ON/OFF
Program Timer
Hot StartHeatingSystem
Night SetbackMode for Cooling
and Heating
Automatic Heatingand CoolingChangeover
Louver Control
Air SweepControl
3 Fan Speedsand AutomaticFan Operation
Dry Mode
Self-DiagnosingFunction
Wired RemoteControl
WirelessRemote Control
Microprocessor-ControlledOperation
Negative IonGenerator
Apatite Filter
Concealed Duct
CeilingRecessed
Wall Mounted
--
--
G
-G
--G
-G
-G
-G
G
G
G
G
OP
G
G
G
G
G
G
OP
G
G
G
G
G
-
G
-
-G
--G
-G
---
G
-
G
G
G G
---
G
OP
OP
-
OP
G
-
-G
G
G
OP
G
G G
OP
G
G
G
G
-
-G
OP
-
G
OP
G
G
--
AIR CONDITIONERS LOW-AMBIENT AIR CONDITIONERS
G
G
G
G
OP
G
G
G
G
G
G
G
G
G
-G
--G
-G
---G
G
G
G G G G G G
G OP OP OP G OP
OP G G G OP G
G G G G G G
G G G G G G
G G G G G G
G G G - G GG G G - G GG G G G G G
- - - - - -G G G G G G
G G G G G G
OP OP OP OP OP OP
- - - - - -OP G G G OP G
OP OP OP OP OP OP
G G G - G GG G G - G GG G G G G G
- OP OP OP - OP
- - G G - -- - G G - -G G G G G G
G G G G G G
G G G G G G
G
G
--
G
-G
G
G
G
-G
--G
-G
-G
-G
G
G
G
G
OP
G
G
G G
G
G
G
--G
G
OP
G
G
G
G
G
-
G
-
-G
--G
-G
G
G
G
G
G - - - - -Quiet Mode G
G
--
G
OP
G
G
G
G
G
G
G
-G
-G
--G
-G
G
G
G
-G
G
G - - - - - -
09KHS7112KHS7118KHS7224KHS7230KHS82
36KHS82
12XHS7118XHS72
26KHS72R
30KHS72R
36KHS72R
26THW72R
36THW72R
42THW42R
26XHW72R
36XHW72R
42XHW72R
26UHW72R36UHW72R
26KHHS72R
26THHW72R36THHW72R
HEAT PUMPS W/O HEATER HEAT PUMPS W/ HEATER
8/7/2019 Sanyo HVAC Catalog
5/28
5
Microprocessor-ControlledOperation
Microprocessor control ensures that thetemperature and humidity levels in the room arealways comfortable.
Wireless Remote ControlSanyos infrared Remote Control withand easy to read LCD Display, gives the
user the capability to adjust & set: temperature,sweep (louver control), fan speeds, timer, nightsetback and more, for complete automaticoperation.
Dry ModeBy coupling compressor and fanoperation, intermittent operation can be
precisely controlled according to roomtemperature, so that air is efficiently dehumidified.
3 Fan Speeds and Automatic
Fan OperationConvenient microprocessor control automaticallyadjusts fan speed to High, Medium or Low.According to room temperature to maintain acomfortable airflow throughout the room.
Air Sweep ControlThe air sweep function moves the louverup and down in the air outlet, directing air
in a sweeping motion around the room andproviding comfort in every corner.
Louver ControlLouver can be manually set to thedesired angle by remote control.
Negative Ions GeneratorThe negative ions generator fills yourroom with negative ions throughout
the year.*Ion generating power - over 100,000 parts/cc
Automatic Heating andCooling Changeover
After setting the temperature and functions youdesire, just relax. If the room temperature ishigher than the set temperature, cooling operation
begins. If the room temperature is lower than theset temperature, he