Previous Issue: 3 September 2006 Next Planned Update: 17 May 2016 Revised paragraphs are indicated in the right margin Page 1 of 30 Primary contact Baldwin, Charles Cummins on 966-3-8760151 Copyright©Saudi Aramco 2010. All rights reserved. Materials System Specification 12-SAMSS-007 17 May 2011 Fabrication of Structural and Miscellaneous Steel Document Responsibility: Onshore Structures Standards Committee Saudi Aramco DeskTop Standards Table of Contents 1 Scope............................................................ 2 2 Conflicts and Deviations................................ 2 3 References.................................................... 2 4 Products and Materials................................. 7 5 Galvanizing, Painting and Coating.............. 10 6 Fabrication................................................... 14 7 Inspection and Testing................................ 27 Appendix 1 ASTM Material Equivalency......... 30

Samss 007

Embed Size (px)

DESCRIPTION

SAMSS-007-

Citation preview

  • Previous Issue: 3 September 2006 Next Planned Update: 17 May 2016

    Revised paragraphs are indicated in the right margin Page 1 of 30

    Primary contact Baldwin, Charles Cummins on 966-3-8760151

    CopyrightSaudi Aramco 2010. All rights reserved.

    Materials System Specification 12-SAMSS-007 17 May 2011

    Fabrication of Structural and Miscellaneous Steel

    Document Responsibility: Onshore Structures Standards Committee

    Saudi Aramco DeskTop Standards Table of Contents 1 Scope............................................................ 2

    2 Conflicts and Deviations................................ 2

    3 References.................................................... 2

    4 Products and Materials................................. 7

    5 Galvanizing, Painting and Coating.............. 10

    6 Fabrication................................................... 14

    7 Inspection and Testing................................ 27 Appendix 1 ASTM Material Equivalency......... 30

  • Document Responsibility: Onshore Structures Standards Committee 12-SAMSS-007

    Issue Date: 17 May 2011

    Next Planned Update: 17 May 2016 Fabrication of Structural and Miscellaneous Steel

    Page 2 of 30

    1 Scope

    This Specification defines the requirements for material selection, connections,

    detailing, fabrication, galvanizing, painting and coatings, marking for erection and

    delivery of structural and miscellaneous steel. Erection of structural steel shall be per

    12-SAMSS-008. Offshore structures and pre-engineered metal buildings are excluded

    from this specification.

    2 Conflicts and Deviations

    2.1 Any conflicts between this Specification and other applicable Saudi Aramco

    Materials System Specifications (SAMSSs), Engineering Standards (SAESs),

    Standard Drawings (SASDs) or industry standards, codes, and forms shall be

    resolved in writing by the Company or Buyer Representative through the

    Manager, Consulting Services Department.

    2.2 Direct all requests to deviate from this Specification in writing to the Company or

    Buyer Representative, who shall follow internal company procedure SAEP-302

    and forward such requests to the Manager, Consulting Services Department of

    Saudi Aramco, Dhahran.

    3 References

    The selection of material and equipment, and the design, construction, maintenance, and

    repair of equipment and facilities covered by this Specification shall comply with the

    latest edition of the references listed below, unless otherwise noted.

    3.1 Saudi Aramco References

    Saudi Aramco Engineering Procedure

    SAEP-302 Instructions for Obtaining a Waiver of a

    Mandatory Saudi Aramco Engineering

    Requirement

    Saudi Aramco Engineering Standards

    SAES-B-063 Aviation Obstruction Marking and Lighting

    SAES-H-001 Coating Selection and Application Requirements

    for Industrial Plants and Equipment

    SAES-H-100 Coating Material and Application Requirements

    for Industrial Facilities

    SAES-H-101 Approved Protective Coating Systems

  • Document Responsibility: Onshore Structures Standards Committee 12-SAMSS-007

    Issue Date: 17 May 2011

    Next Planned Update: 17 May 2016 Fabrication of Structural and Miscellaneous Steel

    Page 3 of 30

    Saudi Aramco Materials System Specification

    12-SAMSS-008 Erection of Structural and Miscellaneous Steel

    Saudi Aramco Standard Drawing

    AA-036322 Anchor Bolt Details Inch and Metric Sizes

    Saudi Aramco Inspection Requirements

    Form 175-120100 Steel Structures

    Form 175-120500 Tower: Communication

    Saudi Aramco Forms and Data Sheets

    SA-7927 Non-Material Requirements for Fabricated

    Structural Steel

    3.2 Industry Codes and Standards

    American Institute of Steel Construction (AISC)

    AISC Detailing for Steel Construction

    AISC Steel Construction Manual, Thirteenth Edition

    AISC Specification for Structural Steel Buildings

    AISC Specification for Structural Joints Using

    ASTM A325 or ASTM A490 Bolts

    AISC Code of Standard Practice for Steel Buildings and

    Bridges

    American Society for Testing and Materials (ASTM)

    ASTM A1 Standard Specification for Carbon Steel Tee Rails

    ASTM A6/A6M Standard Specification for General Requirements

    for Rolled Structural Steel Bars, Plates,

    Shapes, and Sheet Piling

    ASTM A36/A36M Standard Specification for Carbon Structural Steel

    ASTM A53/A53M Standard Specification for Pipe, Steel, Black and

    Hot-Dipped, Zinc-Coated, Welded and Seamless

    ASTM A106/A106M Standard Specification for Seamless Carbon Steel

    Pipe for High-Temperature Service

    ASTM A108 Standard Specification for Steel Bar, Carbon and

    Alloy, Cold Finished

  • Document Responsibility: Onshore Structures Standards Committee 12-SAMSS-007

    Issue Date: 17 May 2011

    Next Planned Update: 17 May 2016 Fabrication of Structural and Miscellaneous Steel

    Page 4 of 30

    ASTM A123/A123M Standard Specification for Zinc (Hot-Dip

    Galvanized) Coatings on Iron and Steel

    Products

    ASTM A143/A143M Standard Practice for Safeguarding Against

    Embrittlement of Hot-Dip Galvanized

    Structural Steel Products and Procedure for

    Detecting Embrittlement

    ASTM A153/A153M Standard Specification for Zinc Coating (Hot-Dip)

    on Iron and Steel Hardware

    ASTM A193/A193M Standard Specification for Alloy-Steel and

    Stainless Steel Bolting for High Temperature or

    High Pressure Service and Other Special

    Purpose Applications

    ASTM A194/A194M Standard Specification for Carbon and Alloy Steel

    Nuts for Bolts for High Pressure or High

    Temperature Service, or Both

    ASTM A307 Standard Specification for Carbon Steel Bolts and

    Studs, 60,000 psi Tensile Strength

    ASTM A325 Standard Specification for Structural Bolts, Steel,

    Heat Treated, 120/105 ksi Minimum Tensile

    Strength

    ASTM A325M Standard Specification for Structural Bolts, Steel,

    Heat Treated 830 MPa Minimum Tensile

    Strength [Metric]

    ASTM A384/A384M Standard Practice for Safeguarding Against

    Warpage and Distortion during Hot-Dip

    Galvanizing of Steel Assemblies

    ASTM A385/A385M Standard Practice for Providing High-Quality

    Zinc Coatings (Hot-Dip)

    ASTM A490 Standard Specification for Structural Bolts, Alloy

    Steel, Heat Treated, 150 ksi Minimum Tensile

    Strength

    ASTM A490M Standard Specification for High-Strength Steel

    Bolts, Classes 10.9 and 10.9.3, for Structural

    Steel Joints (Metric)

    ASTM A500/A500M Standard Specification for Cold-Formed Welded

    and Seamless Carbon Steel Structural Tubing

    in Rounds and Shapes

  • Document Responsibility: Onshore Structures Standards Committee 12-SAMSS-007

    Issue Date: 17 May 2011

    Next Planned Update: 17 May 2016 Fabrication of Structural and Miscellaneous Steel

    Page 5 of 30

    ASTM A501 Standard Specification for Hot-Formed, Welded

    and Seamless Carbon Steel Structural Tubing

    ASTM A563 Standard Specification for Carbon and Alloy Steel

    Nuts

    ASTM A563M Standard Specification for Carbon and Alloy Steel

    Nuts [Metric]

    ASTM A572/A572M Standard Specification for High-Strength Low-

    Alloy Columbium-Vanadium Structural Steel

    ASTM A653/A653M Standard Specification for Steel Sheet, Zinc-

    Coated (Galvanized) or Zinc-Iron Alloy-Coated

    (Galvannealed) by the Hot-Dip Process

    ASTM A759 Standard Specification for Carbon Steel Crane

    Rails

    ASTM A780/A780M Standard Practice for Repair of Damaged and

    Uncoated Areas of Hot-Dip Galvanized

    Coatings

    ASTM A786/A786M Standard Specification for Hot-Rolled Carbon,

    Low-Alloy, High-Strength Low-Alloy, and Alloy

    Steel Floor Plates

    ASTM A992/A992M Standard Specification for Structural Steel Shapes

    ASTM A1008/A1008M Standard Specification for Steel, Sheet, Cold-

    Rolled, Carbon, Structural, High-Strength

    Low-Alloy, High-Strength Low-Alloy with

    Improved Formability, Solution Hardened, and

    Baked Hardenable

    ASTM A1011/A1011M Standard Specification for Steel, Sheet and Strip,

    Hot-Rolled, Carbon, Structural, High-Strength

    Low-Alloy, High-Strength Low-Alloy with

    Improved Formability, and Ultra-High Strength

    ASTM B695 Standard Specification for Coatings of Zinc

    Mechanically Deposited on Iron and Steel

    ASTM E376 Standard Practice for Measuring Coating

    Thickness by Magnetic-Field or Eddy-Current

    (Electromagnetic) Examination Methods

    ASTM F436 Standard Specification for Hardened Steel

    Washers

    ASTM F436M Standard Specification for Hardened Steel

  • Document Responsibility: Onshore Structures Standards Committee 12-SAMSS-007

    Issue Date: 17 May 2011

    Next Planned Update: 17 May 2016 Fabrication of Structural and Miscellaneous Steel

    Page 6 of 30

    Washers [Metric]

    ASTM F606 Standard Test Methods for Determining the

    Mechanical Properties of Externally and

    Internally Threaded Fasteners, Washers,

    Direct Tension Indicators, and Rivets

    ASTM F606M Standard Test Methods for Determining the

    Mechanical Properties of Externally and

    Internally Threaded Fasteners, Washers, and

    Rivets [Metric]

    ASTM F959 Standard Specification for Compressible-Washer-

    Type Direct Tension Indicators for Use with

    Structural Fasteners

    ASTM F959M Standard Specification for Compressible-Washer-

    Type Direct Tension Indicators for Use with

    Structural Fasteners [Metric]

    ASTM F1554 Standard Specification for Anchor Bolts, Steel, 36,

    55 and 105-ksi Yield Strength

    ASTM F2329 Standard Specification for Zinc Coating, Hot-Dip,

    Requirements for Application to Carbon and

    Alloy Steel Bolts, Screws, Washers, Nuts, and

    Special Threaded Fasteners

    American Welding Society (AWS)

    AWS D1.1/ D1.1M Structural Welding Code Steel

    AWS D1.3/ D1.3M Structural Welding Code Steel Sheet

    AWS D14.1/D14.1M Specification for Welding of Industrial and Mill

    Cranes and Other Material Handling

    Equipment

    European Standards

    EN 10204 BS EN 10204: Metallic Products Types of Inspection Documents

    BS EN 10025-2 Hot Rolled Products of Structural Steel

    National Association of Architectural Metals Manufacturers (NAAMM)

    NAAMM MBG 531 Metal Bar Grating Manual

    NAAMM MBG 532 Heavy Duty Metal Bar Grating Manual

  • Document Responsibility: Onshore Structures Standards Committee 12-SAMSS-007

    Issue Date: 17 May 2011

    Next Planned Update: 17 May 2016 Fabrication of Structural and Miscellaneous Steel

    Page 7 of 30

    Process Industry Practices (PIP)

    PIP STF05501 Fixed Ladders and Cages Fabrication Details

    PIP STF05511 Fixed Industrial Stairs

    PIP STF05520 Details for Pipe Railing for Walkway and Working

    Surface

    PIP STF05530 Grating Fabrication Details

    Steel Deck Institute (SDI)

    Design Manual for Composite Decks, Form Decks and Roof Decks No. 31

    Steel Joist Institute (SJI)

    Standard Specifications and Load Tables for Steel Joists and Joist Girders

    U.S. Department of Labor, Occupational Safety and Health Administration

    (OSHA)

    OSHA 29 CFR 1910 Occupational Safety and Health Standards

    OSHA 29 CFR 1926 Safety and Health Regulations for Construction

    4 Products and Materials

    4.1 Material Requirements

    4.1.1 All material shall be of new stock.

    4.1.2 The minimum thickness of any part of a structural shape shall be 5 mm.

    4.1.3 Where contact of dissimilar metals will cause galvanic corrosion, a

    suitable insulating material shall be provided between the metals.

    4.2 Structural Shapes, Plates and Bars

    ASTM A36/ASTM A36M (for plates, bars, M, S, HP, C, MC and L-shapes);

    ASTM A572/ASTM A572M, or ASTM A992/ASTM A992M (for WT and

    W-shapes). Commonly accepted structural steel materials and shapes other than

    ASTM may be used in accordance with Appendix 1 of this specification. Any

    difference(s) in the material dimensions, section properties, yield strength or

    tensile strength shall be accounted for in the design calculations.

    Commentary Note:

    Universal Beams and Universal Columns (UB & UC) and split tees rolled to BS EN 10025-2 S355JR/JO may be used as substitutes for W & WT shapes. Commonly accepted shapes include shapes specified to Japanese Standards

  • Document Responsibility: Onshore Structures Standards Committee 12-SAMSS-007

    Issue Date: 17 May 2011

    Next Planned Update: 17 May 2016 Fabrication of Structural and Miscellaneous Steel

    Page 8 of 30

    (JS), British Standards (BS), European Standards (EuroNorm) and German Standards (DIN).

    4.3 Pipe Columns and Handrail

    Pipe for columns or handrail shall be per ASTM A53/A53M Type E or S,

    Grade B or ASTM A106/A106M Grade B.

    4.4 Structural Tubing

    Structural tubing shall be per ASTM A501 or ASTM A500/A500M Grade B.

    4.5 Metal Decking

    Floor and roof metal deck shall be cold-formed steel sheets conforming to

    ASTM A653/A653M or ASTM A1008/A1008M or equal having a minimum

    yield strength of 228 N/mm (33,000 psi). The metal deck shall be galvanized

    and receive a protective coating of zinc conforming to ASTM A653/A653M,

    G90 Coating Designation. Design shall be in accordance with SDI Design

    Manual for Composite Decks, Form Decks and Roof Decks, No. 31.

    4.6 High Strength Bolt Assemblies

    Bolt - ASTM A325 or A325M Type I, ASTM A490 or A490M, if specified on

    the design drawings

    Washer - ASTM F436 or F436M

    Direct Tension Indicator (D.T.I.) Washers - ASTM F959 or F959M, when

    specified on the design drawings

    Heavy Hex Nut - ASTM A563 Grade DH or ASTM A563M Grade 10S

    4.7 Standard Bolt Assemblies

    Bolt - ASTM A307 Grade A, (Hex " - 1" diameter)

    Washer - ASTM F436 or F436M

    Nut - ASTM A563 or A563M Grade A, Heavy Hex

    4.8 Anchor Bolt Assemblies shall be in accordance with Standard Drawing

    AA-036322 Sht. No. 001 (Rev. No. 08 or later) and the following material

    specifications:

    Threaded Anchor Bolts - ASTM A36/ASTM A36M or ASTM F1554, Gr. 36

  • Document Responsibility: Onshore Structures Standards Committee 12-SAMSS-007

    Issue Date: 17 May 2011

    Next Planned Update: 17 May 2016 Fabrication of Structural and Miscellaneous Steel

    Page 9 of 30

    Headed Bolts - ASTM A307 Grade A (Hex " - 1" diameter, Heavy Hex over

    1" diameter)

    Washers - ASTM F436 or ASTM F436M

    Plate Washers - ASTM A36/ASTM A36M

    Nuts - ASTM A563 Grade A, Heavy Hex or ASTM A563M

    4.9 High Strength Anchor Bolt Assemblies shall be in accordance with Standard

    Drawing AA-036322 Sht. No. 001 (Rev. No. 08 or later) and the following

    material specifications:

    Anchor Bolts - ASTM A193/A193M Gr. B7 or ASTM F1554, Gr. 105

    Heavy Hex Nuts - ASTM A194/A194M or ASTM A563, DH or ASTM A563M

    Grade 10S

    Washers - ASTM F436 or ASTM F436M

    Plate Washers - ASTM A36/ASTM A36M

    4.10 Shear Connectors (for composite construction) - Headed Studs

    ASTM A108 Grade 1010 through 1020, AWS D1.1 Section 7, Type B

    4.11 Welding Filler Metal

    Welding filler metal shall be per AWS D1.1, Section 3.3 (including Table 3.1)

    low hydrogen with an electrode strength of 58 ksi (400 MPa) minimum yield

    strength and 70 ksi (480 MPa) minimum tensile strength. (For example, use

    E70XX for SMAW, F7XX-EXXX for SAW, ER70S-X for GMAW, and E7XT-

    X for FCAW.) However, E60XX (410 MPa) electrodes may be used for tack

    welding.

    4.12 Crane Rails

    Rails 60 lb/yd to 84 lb/yd (30 kg/m to 42 kg/m) ASTM A1

    Rails 104 lb/yd to 175 lb/yd (52 kg/m to 88 kg/m) ASTM A759

    4.13 Checkered Floor Plates

    ASTM A786/ASTM A786M Pattern 4 or 5 and ASTM A36/A36M

  • Document Responsibility: Onshore Structures Standards Committee 12-SAMSS-007

    Issue Date: 17 May 2011

    Next Planned Update: 17 May 2016 Fabrication of Structural and Miscellaneous Steel

    Page 10 of 30

    4.14 Steel Bar Grating and Grating Stair Treads

    Steel bar grating and grating stair treads shall be per ASTM A1011/A1011M,

    galvanized per ASTM A123/A123M and comply with NAAMM MBG 531.

    Steel grating shall be rectangular type, with plain 3/16-inch x 1-1/4-inch (5-mm

    x 32-mm bearing bars on 1-3/16-inch (30-mm) spacing with cross bars on 4-inch

    (100-mm) spacing. Grating stair treads shall have abrasive or checkered plate

    nosing.

    4.15 Heavy Duty Metal Bar Grating

    Heavy duty metal bar grating shall comply with NAAMM MBG 532.

    4.16 Grating Fasteners

    Grating shall be securely fastened to the supporting members as shown in

    NAAMM MBG531 and PIP STF05530. When grating clips are used, they shall

    be from a recognized manufacturer with a published datasheet and written

    installation procedures including tightening criteria. The grating fasteners shall

    be of a design that permits installation by a single worker without requiring

    access to the underside of the grating. The grating clips shall be stainless steel

    or shall be galvanized per ASTM A153/ASTM A153M or ASTM B695.

    4.17 Steel Joists

    Steel joist and joist girders shall comply with SJI Standard Specifications and

    Load Tables for Steel Joists and Joist Girders.

    5 Galvanizing, Painting and Coating

    5.1 Fireproofed Steel

    5.1.1 Galvanized steel is acceptable under cementatious fireproofing.

    Galvanized steel that will receive intumescent fireproofing materials

    must be brush-off blasted (sweep blast) and then receive an APCS-1B

    primer prior to the application of the intumescent fireproofing.

    5.1.2 Bare carbon steel that will receive fireproofing shall be prepared as

    follows:

    a) A full APCS-1B system (primer and top coat(s)) shall be applied

    under cementatious fireproofing materials.

    b) APCS-1B primer shall be applied prior to the application of the

    intumescent fireproof materials.

  • Document Responsibility: Onshore Structures Standards Committee 12-SAMSS-007

    Issue Date: 17 May 2011

    Next Planned Update: 17 May 2016 Fabrication of Structural and Miscellaneous Steel

    Page 11 of 30

    5.2 Galvanizing

    5.2.1 All materials, except ASTM A490 or ASTM A490M bolts, and crane

    rails, shall be galvanized. Steel embedded in concrete (including

    ASTM A36/A36M, ASTM A307 and ASTM F1554 anchor bolts) shall

    be hot-dip galvanized.

    5.2.2 Galvanizing of steel shapes, plates and hardware shall be in accordance

    with the following ASTM specifications:

    a) Steel shapes and plates - ASTM A123/A123M

    b) ASTM A325 Type 1 or ASTM A325M Type 1 bolts and

    corresponding nuts and washers -ASTM B695 or ASTM F2329

    c) ASTM A36/A36M threaded bar or ASTM A307 bolts and

    corresponding nuts and washers - ASTM F2329 or ASTM B695

    d) All bolts, nuts, and washers shall meet required mechanical

    properties after galvanizing.

    5.2.3 General Fabrication

    5.2.3.1 It shall be the Fabricator's responsibility to safeguard

    against embrittlement and warpage per

    ASTM A143/A143M and ASTM A384/A384M.

    5.2.3.2 Fabrication details shall meet the requirements of

    ASTM A385/A385M to allow for the creation of high

    quality zinc coatings.

    5.2.3.3 Whenever practical, cutting, drilling and welding shall be

    performed before galvanizing. The Fabricator shall remove

    weld slag before galvanizing.

    5.2.3.4 The edges of tightly contacting surfaces shall be completely

    seal welded.

    5.2.3.5 Vent holes shall be provided for piping or tubular

    assemblies as required by ASTM A385/A385M. The vent

    holes shall be located in the bottom side to prevent

    rainwater accumulation.

    5.2.3.6 The Fabricator before proceeding shall bring potential

    problems that require a modification in design to the

    attention of the Buyer.

  • Document Responsibility: Onshore Structures Standards Committee 12-SAMSS-007

    Issue Date: 17 May 2011

    Next Planned Update: 17 May 2016 Fabrication of Structural and Miscellaneous Steel

    Page 12 of 30

    5.2.4 Galvanizing of Steel Hardware

    5.2.4.1 Nuts shall be tapped oversize in accordance with

    ASTM A563 or ASTM A563M.

    5.2.4.2 Nut threads shall be retapped after hot-dip galvanizing to

    provide proper fit.

    5.2.4.3 Direct tension indicators, if used, shall be mechanically

    galvanized by the manufacturer according to the

    requirements of Class 50 of ASTM B695.

    5.2.4.4 Anchor bolt coatings shall be in accordance with Standard

    Drawing AA-036322 Sht. No. 001 (Rev. No. 08 or later).

    5.2.5 Inspection of Galvanized Steel

    The Buyer reserves the right to inspect and reject all galvanized steel in

    accordance with the provisions of ASTM A123/A123M and

    ASTM E376.

    5.2.6 Repair of Galvanized Steel

    5.2.6.1 Any damage to galvanizing shall be repaired in accordance

    with ASTM A780/A780M.

    5.2.6.2 Before repair of damaged galvanized coating, exposed

    substrate metal shall be cleaned to bright metal and free of

    all visual rust, oil, or grease. Any non-adhering galvanizing

    shall be removed to the extent that the surrounding

    galvanizing is integral and adherent.

    5.2.6.3 When surface defects exceed 2% of a member's area, the

    defects shall be repaired by redipping the member in the

    zinc bath.

    5.2.6.4 Cold repair using an organic zinc rich coating (primer in

    APCS-1C) shall be permitted if the following conditions

    exist:

    a. Total damaged area is less than 1% of the total coated

    area of the member being repaired

    b. No single repair is greater than 2 square inches

    (1300 mm)

    5.2.6.5 Only products approved under APCS-1C shall be used.

  • Document Responsibility: Onshore Structures Standards Committee 12-SAMSS-007

    Issue Date: 17 May 2011

    Next Planned Update: 17 May 2016 Fabrication of Structural and Miscellaneous Steel

    Page 13 of 30

    5.2.6.6 Hot repairs shall be made in the shop if any of the following

    conditions exist:

    a. Total damaged area is greater than 1% but less than

    2% of the total coated area of the member being

    repaired

    b. Any single repair is at least 2 in (1,300 mm) in area

    c. Any single repair is 12-inches (300 mm) long or more

    5.2.6.7 Hot repair shall be made using zinc alloy rod or powder

    manufactured for the repair of galvanized steel.

    5.2.6.8 Flux, heavy ash, or heavy dross inclusions shall be removed

    by brushing, grinding, or filing as required.

    5.2.6.9 Galvanized steel which has been rejected shall be stripped,

    regalvanized, and submitted again for inspection.

    5.2.6.10 Correction of excessive warpage that exceeds

    ASTM A6/A6M criteria, shall be by press straightening if

    possible. The application of localized heating to straighten

    must be approved by the Chairman of the Onshore

    Structures Standards Committee.

    5.2.6.11 If galvanized tension control bolts are used, all bare steel

    surfaces (i.e., bolt ends) shall be repair galvanized per this

    section.

    5.3 Painting and Coatings

    5.3.1 Where hot-dip galvanizing cannot be done after fabrication, uncoated

    locations shall be painted in accordance with the Saudi Aramco

    Engineering Standards SAES-H-001, SAES-H-100 and SAES-H-101.

    5.3.2 Where fireproofing of structural steel is specified, the steel shall be

    coated with materials that are qualified and approved in accordance

    with SAES-H-001, APCS-1B, Epoxy Coated System with Epoxy

    Primer (also see section 5.1.2).

    5.3.3 Shop painting is not required unless specified in the Purchase Order,

    except for communication towers, which require painting, aviation

    marking and lighting as follows:

    a) Surface preparation and dry film thickness requirements shall be

    in accordance with SAES-H-001, APCS-1E.

  • Document Responsibility: Onshore Structures Standards Committee 12-SAMSS-007

    Issue Date: 17 May 2011

    Next Planned Update: 17 May 2016 Fabrication of Structural and Miscellaneous Steel

    Page 14 of 30

    b) Minimum and maximum overcoating times must be in strict

    accordance with the Manufacturer's Product Data Sheet, and all

    coatings must be qualified and approved in accordance with

    SAES-H-001, APCS-1E.

    c) Aviation marking shall be in compliance with SAES-B-063.

    5.3.4 Floor plate shall be coated with an anti-skid paint per SAES-H-001,

    APCS-12, when required to be shop applied in the contract documents.

    5.3.5 High-strength anchor bolts shall be coated in accordance with Standard

    Drawing AA-036322 Sht. No. 001 (Rev. No. 08 or later).

    5.4 Fixed Ladders and Cages

    Fixed ladders and cages shall comply with PIP STF05501.

    5.5 Fixed Industrial Stairs

    Fixed industrial stairs shall comply with PIP STF05511.

    5.6 Pipe Railing for Walkway and Working Surfaces

    Pipe railing for walkway and working surfaces shall comply with PIP Standard

    STF05520. Angle railing shall not be used.

    5.7 Grating Details

    Grating details shall comply with STF05530.

    6 Fabrication

    6.1 General

    6.1.1 All fabrication shall be in accordance with the AISC Code of Standard

    Practice for Steel Buildings and Bridges and the AISC Specification

    for Structural Steel Buildings.

    6.1.2 All structural steel shall be made by open hearth, basic oxygen or

    electric furnace process. Bessemer steel is not acceptable.

    6.1.3 No rimmed or capped steel shall be used.

    6.1.4 Structural steel pipe shall be limited to seamless or electric-welded,

    straight-seam pipe. Where steel pipes or tubing are used, all open ends

    shall be sealed to prevent internal corrosion.

  • Document Responsibility: Onshore Structures Standards Committee 12-SAMSS-007

    Issue Date: 17 May 2011

    Next Planned Update: 17 May 2016 Fabrication of Structural and Miscellaneous Steel

    Page 15 of 30

    6.1.5 The welding symbols used on plans and shop drawings shall be per the

    American Welding Society (AWS). The field connection symbols

    shall distinguish between assembly yard and erection site connections.

    6.1.6 All welding shall be in accordance with AWS D1.1/D1.1M, Structural

    Welding Code Steel or AWS D.1.3, Structural Welding Code Sheet Steel, as appropriate.

    6.1.7 Shop splices, substitutions of member sizes, or changes in details or

    dimensions shall not be permitted without written authorization from

    the Chairman of the Onshore Structures Standards Committee.

    6.1.8 In order to reduce field connections to a minimum, shop assembly shall

    be as complete as possible, consistent with the feasibility and economy

    of the handling and shipping of the assembled units. Sections or

    assemblies too long for shipment shall be provided with field joints of

    the same member strength.

    6.1.9 Lifting lugs required for lifting of fully assembled structural units or

    skids shall be designed for attachment to primary structural members

    only. Lifting lugs shall be attached by means of a complete joint-

    penetration groove weld or continuous fillet welds (see paragraph

    7.6.e).

    A design factor of safety of 5 shall be applied to all limit states for the lifting lug and its attachment.

    Eccentric forces and impact factors shall be considered in the design of the lugs and their attachment.

    Block outs in the support beam flange to accommodate lifting lugs shall be attached to the lug plate in a manner to develop the full

    tension capacity of the flange.

    Also see section 6.2.6.2 for additional welding requirements.

    6.1.10 All beams, except cantilevers, shall be fabricated with natural mill

    camber in the up position.

    6.1.10 All re-entrant corners shall be shaped, notched-free, to a radius.

    6.1.12 Fabricator, when performing shop assembly work, shall not exceed the

    tolerances specified in AISC Code of Standard Practice for Steel

    Buildings and Bridges.

    6.1.13 Base plate hole sizes for structural steel columns shall be as follows:

  • Document Responsibility: Onshore Structures Standards Committee 12-SAMSS-007

    Issue Date: 17 May 2011

    Next Planned Update: 17 May 2016 Fabrication of Structural and Miscellaneous Steel

    Page 16 of 30

    Anchor bolts to 7/8 inch (12-22 mm) 5/16 inch (8 mm) oversize

    Anchor bolts 1 to 1-3/4 inch (25-44 mm) inch (12 mm) oversize

    Anchor bolts over 2 to 2-1/4 inch (50 - 57 mm) 3/4 inch (19 mm) oversize

    Anchor bolts 2-1/2 inch and over (64 mm) 1 inch (25 mm) oversize

    6.1.14 All pieces shall be clearly marked with permanent identifying erection

    mark number. Method and location of marking shall be approved by

    Buyer.

    6.1.15 Before surface preparation, the Fabricator shall remove all sharp

    corners, burrs (including bolt hole burrs), weld spatter, slag, weld flux,

    loose mill scale and other foreign matter.

    6.1.16 Exposed corners, edges, burrs or rough spots on handrails, guards,

    ladders, platforms and stairs, which might cause injury to personnel

    using the assembled structure, shall be ground or filed smooth.

    6.1.17 Platforms, stairways and handrails shall be shop-assembled in the

    largest units suitable for handling and shipping. Ladder cages shall be

    shop assembled on ladders.

    6.1.18 The method for fastening grating shall be as specified on the design

    drawings and shall also comply with the requirements in section 4.15

    of this specification. A minimum of two fasteners per panel shall be

    used at each support, with a minimum of four fasteners per panel.

    The fasteners shall be supplied by the Fabricator with 5% extra to

    cover losses.

    6.1.19 Grating / checkered plate openings dimensioned on the design

    drawings shall be cut and banded in the shop as shown on the design

    drawing. Undimensioned grating/checkered plate openings will be cut

    in the field by others.

    6.1.20 Joints perpendicular to the span of grating and checkered plate flooring

    shall occur only over support members.

    6.1.21 Checkered plate shall have inch (12 mm) diameter drain holes (when

    specified on contract drawings) provided for each 20 ft (2 m) of area,

    with a minimum of one hole per panel.

    6.2 Connections

    All connections shall be either engineer-designed, fabricator-selected, or

  • Document Responsibility: Onshore Structures Standards Committee 12-SAMSS-007

    Issue Date: 17 May 2011

    Next Planned Update: 17 May 2016 Fabrication of Structural and Miscellaneous Steel

    Page 17 of 30

    fabricator-designed. Unless otherwise noted on the design drawings, all

    connections not fully detailed on the design drawings shall be fabricator-

    designed or fabricator-selected as defined below.

    6.2.1 Engineer-Designed Connections

    6.2.1.1 Engineer-designed connections will be fully designed and

    detailed on the design drawings and shall be furnished as

    shown.

    6.2.1.2 Engineer-designed connections shall be only those

    connections fully detailed on the design drawings, showing

    all fastener sizes, arrangement, dimensions, and all

    connection material, and weld types, sizes and the length

    for each individual member or part to be joined. The

    fabricator shall reflect this information on shop drawings.

    6.2.1.3 Requests to deviate from the specific details of any

    engineer-designed connection by the Fabricator must be in

    writing, with written approval from Saudi Aramco.

    6.2.2 Fabricator-Selected Connections

    Fabricator-selected connections are usually simple connections (shear

    only). The Fabricator shall detail these connections by selecting

    standard details from the AISC Steel Construction Manual Part 10,

    Table 10-2 or Table 10-3.

    6.2.3 Fabricator-Designed Connections

    6.2.3.1 Fabricator-Designed connections shall be designed and

    detailed by the Fabricator to carry all loads shown on the

    design drawings or as specified in the contract documents.

    6.2.3.2 The Fabricator shall have an experienced Structural

    Engineer design or supervise the design of all fabricator-

    designed connections.

    6.2.3.3 Fabricator-designed connections shall meet all requirements

    of the contract documents. In all cases, design shall

    consider the entire joint (including beams, girders, columns,

    and bracing) and shall take into account all applicable limit

    states, including bolt shear, combined bolt tension and

    shear, prying action, local bending, coped beam capacities,

    block shear, web buckling, etc. The Fabricator shall design

  • Document Responsibility: Onshore Structures Standards Committee 12-SAMSS-007

    Issue Date: 17 May 2011

    Next Planned Update: 17 May 2016 Fabrication of Structural and Miscellaneous Steel

    Page 18 of 30

    and furnish stiffeners for column webs, column flanges and

    elements of other members involved as required.

    6.2.3.4 If transfer forces (axial forces at ends of beams and girders)

    are shown on the design drawings, framed beam

    connections shall be designed to carry the transfer forces in

    combination with the beam end reactions.

    6.2.3.5 Checked engineering calculations for each Fabricator-

    designed connection shall be sealed and signed by the

    responsible structural engineer who designed or supervised

    the design of the connections. Additionally, where required

    by the contract documents, all shop drawings containing

    fabricator-designed connections shall be sealed and signed

    by the responsible structural engineer and shall be

    submitted to the Saudi Aramco Representative for review.

    6.2.3.6 Review of shop drawings detailing fabricator-designed

    connections and engineering calculation sheets by the Saudi

    Aramco Representative does not relieve the Fabricator of

    the responsibility for both the design adequacy and

    detailing of connections designed by the Fabricator.

    6.2.4 Allowable Stress Increase

    The Fabricator shall not increase allowable stresses in the design of

    connections (i.e., no one-third increase for wind and seismic as

    required by ASD), unless noted otherwise on the design drawings (if

    LRFD design is used).

    6.2.5 Bolted Connections

    6.2.5.1 Design, detailing, and fabrication of bolted connections

    shall be in accordance with either the AISC Allowable

    Stress Design (ASD) or Load and Resistance Factor Design

    (LRFD) method, as noted in the contract documents.

    6.2.5.2 Connection design shall conform to the following standards:

    a) AISC Specification for Structural Joints using

    ASTM A325 or A490 Bolts

    b) AISC Steel Construction Manual

    c) AISC Detailing for Steel Construction

  • Document Responsibility: Onshore Structures Standards Committee 12-SAMSS-007

    Issue Date: 17 May 2011

    Next Planned Update: 17 May 2016 Fabrication of Structural and Miscellaneous Steel

    Page 19 of 30

    6.2.5.3 ASTM A325/A325M high-strength bolts, inch (20 mm)

    in diameter, shall be used in all bolted structural

    connections, unless otherwise noted in the contract

    documents. However, larger ASTM A325/A325M bolts

    may be used when required to meet connection capacity

    requirements and shall be clearly flagged on the erection

    drawings.

    6.2.5.4 All ASTM A325 or ASTM A325M high-strength bolts,

    shall be Type 1, galvanized. Galvanized washers and nuts

    shall be furnished for galvanized bolts.

    6.2.5.5 All bolts, nuts, and washers shall be properly identified and

    marked with the material grade and manufacturer's logo if

    required by respective ASTM standard. All fasteners not so

    marked shall be rejected. Should any unmarked fasteners

    be installed, they shall be removed. Mechanical testing of

    unmarked fasteners shall not constitute justification for their

    use.

    6.2.5.6 The minimum available strength of all bolted, or mixed

    bolted and welded, framed-beam connections shall be the

    member end reaction shown on the design drawings. If the

    member end reaction is not shown, the minimum available

    strength shall be one-half of the maximum total uniform

    load capacity as shown in the Maximum Total Uniform

    Load Tables in AISC Steel Construction Manual for the

    given beam size, span, and grade of material, unless

    otherwise specified in the contract documents. In addition

    to vertical load, all beam connections shall be designed to

    transfer an assumed longitudinal force equal to 5% of the

    dead and live load. If not shown on the drawings, loads

    shall be based on the Maximum Total Uniform Load

    Tables.

    6.2.5.7 The minimum number of bolts in a framed beam connection

    shall be two bolts.

    6.2.5.8 High-strength bolted connections shall be bearing-type in

    accordance with A325-N with the threads included in the

    shear plane.

    6.2.5.9 Slip-critical connections in accordance with A325-SC shall

    be used if noted on the contract documents.

  • Document Responsibility: Onshore Structures Standards Committee 12-SAMSS-007

    Issue Date: 17 May 2011

    Next Planned Update: 17 May 2016 Fabrication of Structural and Miscellaneous Steel

    Page 20 of 30

    6.2.5.10 All high-strength bolts shall be fully tightened, unless they

    are clearly identified on the design drawings to be tightened

    only to a snug-tight condition.

    6.2.5.10 Ladder, stair tread, purlin, girt, doorframe and handrail

    connections may be made with standard machine bolts,

    conforming to ASTM A307.

    6.2.5.11 ASTM A307 bolts, when used, shall be limited in size to

    85 inch (16 mm) diameter and smaller.

    6.2.5.12 All bolt holes shall be standard holes as defined in Tables

    J3.3 and J3.3M of the AISC Specification for Structural

    Steel Buildings, unless otherwise specified on the design

    drawings or noted in the following subsections.

    6.2.5.13 For framed-beam bearing connections, horizontal short-

    slotted holes are permitted in the outstanding leg of clip

    angles if approved by the engineer of record.

    6.2.5.14 For framed beam slip-critical connections, oversized or

    horizontal short slotted holes as defined in Tables J3.3 and

    J3.3M of the AISC Specification for Structural Steel

    Buildings may be used in the outstanding legs of clip angles

    if approved by the engineer of record. However, in both

    these cases bolt shear allowable loads are reduced, as

    shown in Tables 7-3 or 7-4, of the AISC Steel Construction

    Manual.

    6.2.5.15 For slotted holes, the long direction of the slot shall be

    perpendicular to the load direction. All slotted or oversize

    hole dimensions shall be as defined in Tables J3.3 and

    J3.3M of the AISC Specification for Structural Steel

    Buildings.

    6.2.5.16 Hardened washers shall be provided under all bolt heads

    and/or nuts adjacent to any ply with oversized or slotted

    holes. For standard holes, a minimum of one hardened

    washer shall be supplied with each bolt.

    6.2.5.17 If direct tension indicator washers are used, they shall be in

    accordance with ASTM F959/F959M and shall be installed

    according to the washer manufacturer's published

    specifications.

  • Document Responsibility: Onshore Structures Standards Committee 12-SAMSS-007

    Issue Date: 17 May 2011

    Next Planned Update: 17 May 2016 Fabrication of Structural and Miscellaneous Steel

    Page 21 of 30

    6.2.5.18 Where high-strength bolts are used, "turn-of-nut" or "load

    indicating washer" methods may be used for bolt

    tightening. Temporary shop erection bolts must be

    removed and replaced with high-strength bolts. A marking

    system shall be used to mark high-strength bolted

    connections after tightening is completed.

    6.2.5.19 All bolt lengths shall be determined from the Commentary

    in Specifications for Structural Joints Using ASTM A325 or

    ASTM A490 Bolts, Table C-2.2.

    6.2.5.20 A minimum of 5% extra quantities of each bolt size and

    length, including nuts and washers, shall be furnished by

    the fabricator for field erection.

    6.2.5.21 All column splices shall be field-bolted and conform to

    AISC Detailing for Steel Construction.

    6.2.5.22 A washer shall be furnished with each anchor bolt. Plate

    washer thicknesses shall be as shown on the design

    drawings.

    6.2.5.23 All nuts for high-strength bolts shall be wax-dipped to

    reduce torque during installation.

    6.2.5.24 As required by OSHA 29 CFR 1926 Subpart R, when two

    structural members on opposite sides of a column web, or a

    beam web over a column, are connected sharing common

    connection holes, the fabricator shall provide means of

    supporting one member while erecting the other member.

    Unless the means of support is indicated in the contract

    documents, the fabricator may provide one additional row

    of bolts in the member to be erected first, an erection seat

    for the member to be erected first, or other suitable means.

    Unless additional loading is indicated, the erection seat

    shall be sized and attached to the column or supporting

    beam web with sufficient bolts to support the dead weight

    of the member. See the OSHA document for additional

    information.

    6.2.6 Welded Connections

    6.2.6.1 Design, detailing, and fabrication of welded connections

    shall be in accordance with either AISC's Allowable Stress

  • Document Responsibility: Onshore Structures Standards Committee 12-SAMSS-007

    Issue Date: 17 May 2011

    Next Planned Update: 17 May 2016 Fabrication of Structural and Miscellaneous Steel

    Page 22 of 30

    Design (ASD) or Load and Resistance Factor Design

    (LRFD) method, as noted in the Contract Documents.

    6.2.6.2 Welded connection design shall be in accordance with

    AWS D1.1, AISC Steel Construction Manual and AISC

    Detailing for Steel Construction. Welding for monorail,

    lifting lugs and other below the hook devices required for

    lifting or rigging shall conform to AWS D14.1.

    6.2.6.3 The minimum available strength of all welded framed beam

    connections shall be the member end reaction shown on the

    design drawings. If the member end reaction is not shown

    on the design drawings, the minimum available strength

    shall be one-half of the values shown in the Maximum

    Total Uniform Load Tables in the AISC Steel Construction

    Manual for the given beam size, span, and grade of

    material, unless otherwise specified in the contract

    documents.

    6.2.6.4 The minimum fillet weld size is 3/16 inch (5 mm) for

    structural welds. Seal welds may be 1/8 inch (3 mm)

    minimum fillet weld.

    6.2.6.5 All structural strength welding shall be continuous, unless

    alternate procedures are approved by the Chairman of the

    Onshore Structures Standards Committee.

    6.2.6.6 The Fabricator shall design and install erection clips for

    field-welded connections.

    6.2.6.7 Field connections for random-length materials of handrail

    and ladder cage assemblies shall be welded.

    6.2.6.8 Continuous seal-welding shall be used in places that are not

    self-draining or where crevice corrosion is likely to occur.

    If seal-welding is not practical, alternative methods of

    sealing shall be used with the approval of the Saudi Aramco

    Representative.

    6.2.6.9 Fabricator shall remove all run-off bars and extension tabs.

    6.2.7 Shop and Field Connections

    6.2.7.1 All field connections shall be bolted and all shop

    connections shall be either bolted or welded, unless

    otherwise shown on the design drawings.

  • Document Responsibility: Onshore Structures Standards Committee 12-SAMSS-007

    Issue Date: 17 May 2011

    Next Planned Update: 17 May 2016 Fabrication of Structural and Miscellaneous Steel

    Page 23 of 30

    6.2.7.2 Single-angle shear connections shall not be used.

    6.2.7.3 To ensure electrical continuity if shop-applying non-

    conductive coatings (i.e., epoxies), all contact surfaces shall

    be masked unless otherwise noted in the contract

    documents. All locations of no-paint or areas requiring full

    masking or strip masking shall be noted on the shop

    drawings.

    6.2.8 Bracing Connections

    6.2.8.1 Unless otherwise noted on the design drawings, connections

    for pre-assembled bracing and truss members shall be

    designed for the forces shown on the design drawings, but

    not less than 50% of allowable tension capacity of the

    members or 6 kips (27 Kn), whichever is greater. The

    available tension strength of a member shall be calculated

    using the gross cross section of the member. A minimum

    of two bolts per connection is required.

    6.2.8.2 All cross-bracing shall be bolted at intersections with one

    bolt minimum for angles and two bolts minimum for tees.

    6.2.8.3 All bracing connections, including gusset plates, shall be

    designed in accordance with the AISC Steel Construction

    Manual.

    6.2.8.4 All gusset and stiffener plates shall be 3/8 inch (10 mm)

    minimum thickness. For minor structures such as platforms

    and miscellaneous structures, inch (6 mm) thick gusset

    and stiffener plates may be used. The minimum thickness

    for connection plates in electrical transmission towers or

    communication towers shall be inch (6 mm).

    6.2.8.5 Unless otherwise noted on the design drawings, all vertical

    bracing and knee bracing shall have gusset plates on

    column centerlines.

    6.2.8.6 Unless otherwise noted on the design drawings, the

    following working points shall be used:

    a) For vertical bracing at the intersection of a column,

    beam and brace, the gusset plate shall be connected to

    both beam and column. The work point shall be the

    point at which the beam and column centerlines

    intersect.

  • Document Responsibility: Onshore Structures Standards Committee 12-SAMSS-007

    Issue Date: 17 May 2011

    Next Planned Update: 17 May 2016 Fabrication of Structural and Miscellaneous Steel

    Page 24 of 30

    b) For the connection of V-braces to nominal beams

    10 inches (250 mm) or smaller, the working point

    shall be the intersection of the horizontal centerline of

    the beam and the centerline of the bay.

    c) For the connection of V-braces to nominal beams

    12 inches (300 mm) or larger, the working point shall

    be the intersection of a horizontal line 5-inches

    (125 mm) below the top flange if the brace is above

    the beam, or 5-inches (125 mm) above the bottom

    flange if the brace is below the beam, and the

    centerline of the bay.

    6.2.9 Connections for Concrete Fireproofed Members

    6.2.9.1 Connections for members fireproofed with concrete shall be

    detailed to minimize blockouts in shop applied fireproofing.

    6.2.9.2 Gusset plates for vertical or horizontal bracing members

    and single-plate shear connections for beams shall extend

    outside fireproofing a sufficient length to make the

    connection with the fireproofing in place.

    6.2.9.3 Handrails shall not be connected to fireproofed columns.

    6.3 Handling, Shipping, and Delivery

    6.3.1 Handling and Shipping

    6.3.1.1 Delivery of steel shall be in the order needed for erection.

    The delivery sequence for the fabricated steel, unless

    otherwise noted in the contract documents or arranged by

    Saudi Aramco, shall be as follows:

    a. Anchor bolts

    b. Loose base plates

    c. Steel embedded in concrete

    d. Erection bolts

    e. First tier columns and framing for all its levels

    (including stairs, grating and handrail)

    f. Second tier columns and its framing, etc.

    6.3.1.2 All bolts, washers and nuts shall be packaged and delivered

    in rigid, weatherproof containers. Cardboard containers are

  • Document Responsibility: Onshore Structures Standards Committee 12-SAMSS-007

    Issue Date: 17 May 2011

    Next Planned Update: 17 May 2016 Fabrication of Structural and Miscellaneous Steel

    Page 25 of 30

    not acceptable.

    6.3.1.3 Railcars and/or trucks shall be loaded and cribbed so that

    they can be readily unloaded by others. Load in such a

    manner that continuous drainage is assured.

    6.3.1.4 The Fabricator shall ensure that all steel and its coatings are

    protected from any damage caused by handling, storage or

    shipping prior to receipt by the Buyer.

    6.3.1.5 The Fabricator shall ensure that adequate protection is

    provided for threads on sag rods, anchor bolts, and any

    other threaded components to prevent damage during

    shipping and handling. Care shall be taken that holes and

    surfaces prepared for connection and the threads of bolts,

    anchors, mortises, etc., stay clean and undamaged.

    6.3.1.6 The bottom of base plates shall be clean and free of any rust

    or corrosion.

    6.3.2 Delivery

    6.3.2.1 The Fabricator is responsible for delivering all materials

    and documentation to the job site in good condition.

    All material and documentation will be inspected

    immediately upon receipt by Buyer to determine that all

    items included in the Bill of Materials have been supplied,

    to assure that all documentation has been received, and to

    check for any damage.

    6.3.2.2 All materials designated for the care, custody and control of

    the Erector shall be received, unloaded, stored, and

    otherwise handled in a manner that will prevent distortion,

    deterioration, or damage.

    6.3.2.3 Saudi Aramco reserves the right to reject all damaged or

    substandard material or documentation.

    6.4 Erection and Shop Drawings

    6.4.1 Shop drawings and erection drawings shall be prepared in accordance

    with the AISC documents listed in this specification.

    6.4.2 Erection drawings shall reference the corresponding design drawings.

    Every steel piece on the shop drawings shall reference the appropriate

    erection drawing.

  • Document Responsibility: Onshore Structures Standards Committee 12-SAMSS-007

    Issue Date: 17 May 2011

    Next Planned Update: 17 May 2016 Fabrication of Structural and Miscellaneous Steel

    Page 26 of 30

    6.4.3 Shop drawings shall clearly show the specification and grade of steel to

    be used.

    6.4.4 Erection and shop drawings shall be grouped in sets and identified

    separately for each structure or yard area.

    6.4.5 Erection drawings shall clearly show the mark number and position for

    each member. The mark number system shall be agreed upon in

    advance with the Buyer.

    6.4.6 Erection drawings shall clearly identify slip critical high strength

    bolted connections.

    6.4.7 All fabricated steel sections shall be match-marked for field assembly

    with designating numbers or letters corresponding to the field erection

    drawings. Match-marking of steel shall be done with suitable paint,

    waterproof ink or with pressed metal tags.

    6.4.8 In addition to the Fabricator's identification marks, each item or bundle

    of walkways and platforms shall be marked with a unique tag number to

    clearly indicate its associated equipment. Each item or bundle of

    walkways and platforms shall also be indicated on the erection drawings.

    6.4.9 Shop drawings shall state the welding procedure and welding electrode

    to be used.

    6.4.10 Shop drawings shall clearly show the specification and grade of steel to

    be used.

    6.4.11 The buyer's purchase order number shall be shown on all erection and

    shop drawings.

    6.4.12 Surface preparation and shop-applied coatings, including areas to be

    masked, shall be noted on the shop drawings.

    6.4.13 The Fabricator shall provide a bolt list and a list of other fasteners

    showing the number, grade, size, and length of field bolts for each

    connection. These lists may be shown on either the shop drawings or

    on separate sheets.

    6.4.14 In the event that drawing revisions are necessary, the Fabricator shall

    clearly flag on the shop drawings all changes showing the latest

    revisions.

    6.5 Submittals

    6.5.1 A shipping list (including total weight), a bolt list, and a minimum of

  • Document Responsibility: Onshore Structures Standards Committee 12-SAMSS-007

    Issue Date: 17 May 2011

    Next Planned Update: 17 May 2016 Fabrication of Structural and Miscellaneous Steel

    Page 27 of 30

    two sets of final erection and shop drawings shall accompany the first

    shipment of each release.

    6.5.2 Design drawings including foundation loading diagrams shall be

    provided for approval of the Buyer as specified in the Non-Material

    Requirements, Form SA-7927 attached to the Purchase Order.

    6.5.3 The foundation loading diagram to be provided by the Vendor shall

    show the type, size, location and projection of all anchor bolts for the

    metal system components, and the minimum length and width of the

    foundation required. Column reactions (magnitude and direction) and

    minimum base plate dimensions shall also be included.

    7 Inspection and Testing

    7.1 All NDT procedures shall be submitted to the Inspection Department /

    Operations Inspection Division (OID) ASNT Level-III for acceptance prior to

    work commencing.

    7.2 The Buyer has the right to inspect all materials and workmanship, and shall have

    unrestricted entry to the shop of the Fabricator at all times while work is being

    performed. The Buyer may reject improper, inferior, defective, or unsuitable

    materials and workmanship. All materials and workmanship rejected shall be

    repaired or replaced by the Fabricator as directed by the Buyer. The company

    inspector shall have access to the vendor's facilities to see that SAES-H-100

    quality elements are in place prior to and during blasting, priming and coating

    operations.

    7.3 The Inspection Test Plan (ITP) shall be provided for review and approval by the

    company inspector.

    7.4 Inspection and testing shall conform to this Specification and Saudi Aramco

    Inspection Requirements Forms 175-120100 or 175-120500 attached to the

    Purchase Order.

    7.5 Welding procedures and individual welders shall be qualified in accordance with

    the requirements of AWS D1.1/D1.1M, AWS D1.3 or AWS D14.1 as

    appropriate. All welding procedures and welding performance qualification

    records shall be made available to the Buyer's Inspector for review.

    7.6 Inspection of welding shall be performed in accordance with the Structural

    Welding Code, AWS D1.1/D1.1M. Ultrasonic testing may be substituted for

    radiography if approved by Saudi Aramco Inspection.

    a) All welds shall have 100% visual inspection performed per AWS D1.1.

  • Document Responsibility: Onshore Structures Standards Committee 12-SAMSS-007

    Issue Date: 17 May 2011

    Next Planned Update: 17 May 2016 Fabrication of Structural and Miscellaneous Steel

    Page 28 of 30

    In addition, any strikes, gouges, and other indications of careless

    workmanship (such as surface porosity) shall be removed by grinding.

    b) Pipes used as piling (circumferential welds) and tubular structures shall be

    randomly radiographed at the rate of 10% [one weld of each ten (10) welds

    shall be 100% radiographed]. The specified amount of random

    radiography shall include X-ray samples from each welder's daily

    production.

    c) The butt-welded flange sections for all primary load-bearing members

    shall be 100% radiographed at the weld. Primary load-bearing members

    shall be defined as the main frames and any members that are part of the

    lateral load carrying system. For skids, primary load-bearing members

    shall be defined as; exterior longitudinal and end framing members as well

    as any full-depth cross beams at lifting lug locations.

    d) Secondary members such as purlins, girts or rafters that are not part of the

    main sway frame, the butt-welds can be tested as follows; 10% of the butt-

    welds of each days production (randomly selected) shall have radiographic

    tests performed on the welds.

    e) All lifting lug connections shall be 100% magnetic particle inspected.

    Full penetration groove welds in lifting lugs shall be 100% UT inspected.

    Procedures and operator qualifications shall meet AWS D1.1 and be

    submitted to the Company Inspector for review and approval.

    f) The minimum percent coverage of the specified NDT method may be

    increased (at any level up to 100%) if, in the opinion of the Company

    Inspector, the welds are of questionable workmanship or NDT indicates an

    excessive number of defects. Additional or alternative NDT methods may

    be used at the discretion of the Company Inspector in order to assist in

    determining the type or extent of defects.

    7.7 Material test reports for each heat of structural steel, each lot of high-strength

    and ASTM A307 bolts shall be available for review by the Buyer. Material test

    reports shall conform to EN 10204, Type 3.1.

    7.8 The Buyer may require a quantity of representative samples of bolt assemblies

    which the Fabricator shall supply to the Buyer for testing. Testing in accordance

    with ASTM F606 or ASTM F606M will be at the Buyer's expense.

    7.9 If any damage is discovered, or any parts, components, or documentation are

    missing or otherwise defective, the occurrence shall be immediately reported to

    the Buyer in writing.

    7.10 Shop inspection may include, but not be limited to the following:

  • Document Responsibility: Onshore Structures Standards Committee 12-SAMSS-007

    Issue Date: 17 May 2011

    Next Planned Update: 17 May 2016 Fabrication of Structural and Miscellaneous Steel

    Page 29 of 30

    Verification of conformance of materials with this Specification and the

    drawings. The limits of acceptability and repair of surface imperfections for

    structural steel shall be in accordance with ASTM A6/ASTM A6M.

    7.11 Inspection of high-strength bolted connections shall be in accordance with AISC

    Specification for Structural Joints Using ASTM A325 or ASTM A490 Bolts.

    7.12 The buyer reserves the right to inspect and reject all galvanized steel in

    accordance with ASTM A123/A123M and ASTM E376.

    Revision Summary 17 May 2011 Revised the "Next Planned Update". Reaffirmed the contents of the document, and reissued

    with minor revision.

  • Document Responsibility: Onshore Structures Standards Committee 12-SAMSS-007

    Issue Date: 17 May 2011

    Next Planned Update: 17 May 2016 Fabrication of Structural and Miscellaneous Steel

    Page 30 of 30

    Appendix 1 ASTM Material Equivalency

    ASTM Materials EN Materials ISO Materials JIS Materials

    ASTM A36/A36M EN 10025-2, Gr S275J0 ISO 630-95, E275 C G3106-95, SM490A

    EN 10025-2, Gr S275JR

    ASTM A53 ISO 9329-1, TS430 G3454-88, STPG 410

    ISO 9330-1, TW430

    ASTM A108, G1010 EN 10016-2, C10D ISO 4954, CC 11 X

    G1015 EN 10016-2, C15D ISO 4954, CC 15 K

    G1020 EN 10016-2, C20D ISO 4954, CC 21 K

    ASTM A307 No Substitute No Substitute No Substitute

    ASTM A325 No Substitute No Substitute No Substitute

    ASTM A325M No Substitute ISO 7412 per ASTM A325M No Substitute

    ASTM A500 EN 10219-1, S355J0H G3444-94, STK490

    G3466-88, STKR490

    ASTM A501 EN 10210-1, S275J0H G3444-94, STK490

    G3466-88, STKR490

    ASTM A563 No Substitute No Substitute No Substitute

    ASTM A563M No Substitute ISO 4775 per ASTM A563M No Substitute

    ASTM A1011/A1011M EN 10025-2, Gr S235JR ISO 3573, HR1 G3131, SPHC

    ASTM A572/A572M, G50 EN 10025-2, Gr S355JR ISO 4950-2, E355DD G3106, SM490YA

    G65 EN 10025-2, Gr S450JO ISO 4950-2, E460CC G3106, SM570

    ASTM A759 None ISO 5003 E1101, E1103

    ASTM A992/A992M EN 10025-2, Gr S355JR ISO 630-95, E355 C G3106, SM490YA

    EN 10025-2, Gr S355J0 G3106, SM570

    G3136

    Note: The minimum published yield strength may vary based on the material thickness. Refer to the appropriate material specification.