12
Date received: 12/11/14 Date of issue: 13/01/15 Report consists of 10 test reports. Sample name: BI SAMPLE N° 186033 List performed tests: 1. Safety requirements EN 16139:2013+AC:2013 2. Seat and back static load test EN 1728:2012+AC:2013 3. Vertical load on back rest EN 1728:2012+AC:2013 4. Seat and back fatigue test EN 1728:2012+AC:2013 5. Seat front edge durability test EN 1728:2012+AC:2013 6. Leg forward static load test EN 1728:2012+AC:2013 7. Leg sideways static load test EN 1728:2012+AC:2013 8. Seat impact test EN 1728:2012+AC:2013 9. Back impact test EN 1728:2012+AC:2013 10. Stability - EN 1022:2005 OMP S.R.L. VIA CA' LEONCINO, 2 31030 CASTELLO DI GODEGO (TV) ITALIA The sample name and, when relevant, its description, are given by the orderer, and CATAS does not assume responsibility on this matter. This test report relates to the sample submitted for the test and no others. Additions, deletions or alterations are not permitted. This test report must always be reproduced in its entirety. Unless otherwise stated, sampling has been carried out by the orderer. Page 1 of 2 This document is validated by digital signature and time stamping in accordance with the Italian laws and the European Directives which regulate the electronic signature systems. Managing Director Dr. Andrea Giavon Defects before testing: None Overall dimensions: 490 x 530 x 760 (h) mm CATAS S.p.A. Iscr. Reg. Imprese Udine nr. iscr. C.F. 01818850305 Reg. Impr. UD 20663 P. IVA : 01818850305 C.Soc. 1.003.650,00 i.v. centro ricerche-sviluppo e laboratori prove settori legno-arredo, ambiente e alimenti Sede: Via Antica, 24/3 33048 S. Giovanni al Nat. UD Tel. 0432.747211 r.a. Fax 0432.747250 http://www.catas.com e-mail: [email protected] Filiale: Via Braille, 5 20851 Lissone MB Tel. 039.464567 Fax 039.464565 e-mail: [email protected]

SAMPLE N° 186033 - Meble-Bocian · PDF filevia ca' leoncino, 2 31030 castello di godego (tv) italia

Embed Size (px)

Citation preview

Page 1: SAMPLE N° 186033 - Meble-Bocian · PDF filevia ca' leoncino, 2 31030 castello di godego (tv) italia

Date received: 12/11/14

Date of issue: 13/01/15

Report consists of 10 test reports.

Sample name: BI

SAMPLE N° 186033

List performed tests:1. Safety requirements EN 16139:2013+AC:2013 2. Seat and back static load test EN 1728:2012+AC:2013 3. Vertical load on back rest EN 1728:2012+AC:2013 4. Seat and back fatigue test EN 1728:2012+AC:2013 5. Seat front edge durability test EN 1728:2012+AC:2013 6. Leg forward static load test EN 1728:2012+AC:2013 7. Leg sideways static load test EN 1728:2012+AC:2013 8. Seat impact test EN 1728:2012+AC:2013 9. Back impact test EN 1728:2012+AC:2013 10. Stability - EN 1022:2005

OMP S.R.L. VIA CA' LEONCINO, 2 31030 CASTELLO DI GODEGO (TV) ITALIA

The sample name and, when relevant, its description, are given by the orderer, and CATAS does not assume responsibility on this matter. This test report relates to the sample submitted for the test and no others. Additions, deletions or alterations are not permitted. This test report must always be reproduced in its entirety. Unless otherwise stated, sampling has been carried out by the orderer.

Page 1 of 2

This document is validated by digital signature and time stamping in accordance with the Italian laws and the European Directives which regulate the electronic signature systems.

Managing Director Dr. Andrea Giavon

Defects before testing: None

Overall dimensions: 490 x 530 x 760 (h) mm

CATAS S.p.A. Iscr. Reg. Imprese Udine nr. iscr. C.F. 01818850305 Reg. Impr. UD 20663 P. IVA : 01818850305 C.Soc. € 1.003.650,00 i.v.

centro ricerche-sviluppo e laboratori prove settori legno-arredo, ambiente e alimenti

Sede: Via Antica, 24/3 33048 S. Giovanni al Nat. UD Tel. 0432.747211 r.a. Fax 0432.747250 http://www.catas.com e-mail: [email protected]

Filiale: Via Braille, 5 20851 Lissone MB Tel. 039.464567 Fax 039.464565 e-mail: [email protected]

Page 2: SAMPLE N° 186033 - Meble-Bocian · PDF filevia ca' leoncino, 2 31030 castello di godego (tv) italia

Date of issue: 13/01/15

Sample name: BI

SAMPLE N° 186033

Page 2 of 2

The sample name and, when relevant, its description, are given by the orderer, and CATAS does not assume responsibility on this matter. This test report relates to the sample submitted for the test and no others. Additions, deletions or alterations are not permitted. This test report must always be reproduced in its entirety. Unless otherwise stated, sampling has been carried out by the orderer.

Side view Rear view

Bottom view

Sample weight: Not determined

CATAS S.p.A. Iscr. Reg. Imprese Udine nr. iscr. C.F. 01818850305 Reg. Impr. UD 20663 P. IVA : 01818850305 C.Soc. € 1.003.650,00 i.v.

centro ricerche-sviluppo e laboratori prove settori legno-arredo, ambiente e alimenti

Sede: Via Antica, 24/3 33048 S. Giovanni al Nat. UD Tel. 0432.747211 r.a. Fax 0432.747250 http://www.catas.com e-mail: [email protected]

Filiale: Via Braille, 5 20851 Lissone MB Tel. 039.464567 Fax 039.464565 e-mail: [email protected]

Page 3: SAMPLE N° 186033 - Meble-Bocian · PDF filevia ca' leoncino, 2 31030 castello di godego (tv) italia

TEST REPORT

186033 / 1Date received: 12/11/14Date of test: 13/11/14Date of issue: 13/01/15Sample name: BI

Safety requirements EN 16139:2013+AC:2013

OMP S.R.L.!VIA CA' LEONCINO, 2!31030 CASTELLO DI GODEGO (TV)!ITALIA

CATAS S.p.A. Iscr. Reg. Imprese Udine nr. iscr. C.F. 01818850305 Reg. Impr. UD 20663 P. IVA : 01818850305 C.Soc. € 1.003.650,00 i.v.

centro ricerche-sviluppo e laboratori prove settori legno-arredo, ambiente e alimenti

Sede: Via Antica, 24/3 33048 S. Giovanni al Nat. UD Tel. 0432.747211 r.a. Fax 0432.747250 http://www.catas.com e-mail: [email protected]

Filiale: Via Braille, 5 20851 Lissone MB Tel. 039.464567 Fax 039.464565 e-mail: [email protected]

Safety requirements clause 4Remarks Tecnico 2:Statement checked

Corner and edges in contact with the users:Yes Note:• Absence of sharp edges and corners

Edges on the handles:

Handles not present• Absence of sharp edges and corners in the direction of the force

Other edges:Yes• Absence of corners

Accessible hollow components:Yes• The ends of hollow components are closed or capped

Movable and adjustable parts:

Movable and adjustable parts!not present

• It shall not be possible for any movable and adjustable part of the!chair to come operate unintentionally.

Connections between parts of the structure:

No• It shall not be possible for any load bearing part of the seating!to come loose unintentionally

Parts which are lubricated:

Lubricated parts not present• All the parts which are lubricated shall be designed to protect users

Shear and squeeze points between movable parts ≥ 7 mm ≤ 18 mm:

Mechanism not present• Shear and squeeze points under influence of powered mechanism• Shear and squeeze points during normal use and during normal!movements and actions No

Conformity to clauses 4.1 and 4.2 of standard EN 16139:2013: YES

pag. 1/1

The sample name and, when relevant, its description, are given by the orderer, and CATAS does not assume responsibility on this matter. This test report relates to the sample submitted for the test and no others. Additions, deletions or alterations are not permitted. This test report must always be reproduced in its entirety. Unless otherwise stated, sampling has been carried out by the orderer.

This document is validated by digital signature and time stamping in accordance with the Italian laws and the European Directives which regulate the electronic signature systems.

Managing Director Dr. Andrea Giavon

Page 4: SAMPLE N° 186033 - Meble-Bocian · PDF filevia ca' leoncino, 2 31030 castello di godego (tv) italia

TEST REPORT

186033 / 2Date received: 12/11/14Date of test: 14/11/14Date of issue: 13/01/15Sample name: BI

Seat and back static load test EN 1728:2012+AC:2013

OMP S.R.L.!VIA CA' LEONCINO, 2!31030 CASTELLO DI GODEGO (TV)!ITALIA

CATAS S.p.A. Iscr. Reg. Imprese Udine nr. iscr. C.F. 01818850305 Reg. Impr. UD 20663 P. IVA : 01818850305 C.Soc. € 1.003.650,00 i.v.

centro ricerche-sviluppo e laboratori prove settori legno-arredo, ambiente e alimenti

Sede: Via Antica, 24/3 33048 S. Giovanni al Nat. UD Tel. 0432.747211 r.a. Fax 0432.747250 http://www.catas.com e-mail: [email protected]

Filiale: Via Braille, 5 20851 Lissone MB Tel. 039.464567 Fax 039.464565 e-mail: [email protected]

Seat and back static load test, clause 6.4

Back force!N

Number!of cycles Remarks

EN 16139

828

SI NO

Test results:

a) Rotture di componenti o giunzioni

Seat load!N

2.000 700 10 No defects

Seat front edge static load, clause 6.5

Number!of cycles Remarks

x

xb) Allentamenti di giunzioni xc) No elemento strutturale importante notevolm. def.d) Funzioni inalterate dopo rimoz. carichi x

ApparecchiaturaSeat load!

N

1.600 10 No defects

Note:The test has been carried out according to table 1 of EN 16139:2013, level L2 - extreme.

pag. 1/1

The sample name and, when relevant, its description, are given by the orderer, and CATAS does not assume responsibility on this matter. This test report relates to the sample submitted for the test and no others. Additions, deletions or alterations are not permitted. This test report must always be reproduced in its entirety. Unless otherwise stated, sampling has been carried out by the orderer.

This document is validated by digital signature and time stamping in accordance with the Italian laws and the European Directives which regulate the electronic signature systems.

Managing Director Dr. Andrea Giavon

Page 5: SAMPLE N° 186033 - Meble-Bocian · PDF filevia ca' leoncino, 2 31030 castello di godego (tv) italia

TEST REPORT

186033 / 3Date received: 12/11/14Date of test: 14/11/14Date of issue: 13/01/15Sample name: BI

Vertical load on back rest EN 1728:2012+AC:2013

OMP S.R.L.!VIA CA' LEONCINO, 2!31030 CASTELLO DI GODEGO (TV)!ITALIA

CATAS S.p.A. Iscr. Reg. Imprese Udine nr. iscr. C.F. 01818850305 Reg. Impr. UD 20663 P. IVA : 01818850305 C.Soc. € 1.003.650,00 i.v.

centro ricerche-sviluppo e laboratori prove settori legno-arredo, ambiente e alimenti

Sede: Via Antica, 24/3 33048 S. Giovanni al Nat. UD Tel. 0432.747211 r.a. Fax 0432.747250 http://www.catas.com e-mail: [email protected]

Filiale: Via Braille, 5 20851 Lissone MB Tel. 039.464567 Fax 039.464565 e-mail: [email protected]

Vertical static load on back rest clause 6.6

Downwards!force!

NNumber of !

applications Remarks

EN 16139

SI NOTest results:

a) Rotture di componenti o giunzioni

Seat!load!

Nx

x

1.800 900 10 No defects b) Allentamenti di giunzioni x

c) No elemento strutturale importante notevolm. def.Note: d) Funzioni inalterate dopo rimoz. carichi xThe test has been carried out according to table 1 of EN 16139:2013, level L2 - extreme.

Apparecchiatura

pag. 1/1

The sample name and, when relevant, its description, are given by the orderer, and CATAS does not assume responsibility on this matter. This test report relates to the sample submitted for the test and no others. Additions, deletions or alterations are not permitted. This test report must always be reproduced in its entirety. Unless otherwise stated, sampling has been carried out by the orderer.

This document is validated by digital signature and time stamping in accordance with the Italian laws and the European Directives which regulate the electronic signature systems.

Managing Director Dr. Andrea Giavon

Page 6: SAMPLE N° 186033 - Meble-Bocian · PDF filevia ca' leoncino, 2 31030 castello di godego (tv) italia

TEST REPORT

186033 / 4Date received: 12/11/14Date of test: 17/11/14Date of issue: 13/01/15Sample name: BI

Seat and back fatigue test EN 1728:2012+AC:2013

OMP S.R.L.!VIA CA' LEONCINO, 2!31030 CASTELLO DI GODEGO (TV)!ITALIA

CATAS S.p.A. Iscr. Reg. Imprese Udine nr. iscr. C.F. 01818850305 Reg. Impr. UD 20663 P. IVA : 01818850305 C.Soc. € 1.003.650,00 i.v.

centro ricerche-sviluppo e laboratori prove settori legno-arredo, ambiente e alimenti

Sede: Via Antica, 24/3 33048 S. Giovanni al Nat. UD Tel. 0432.747211 r.a. Fax 0432.747250 http://www.catas.com e-mail: [email protected]

Filiale: Via Braille, 5 20851 Lissone MB Tel. 039.464567 Fax 039.464565 e-mail: [email protected]

Seat and back fatigue test, clause 6.17

Back force!N

Number!of cycles Remarks

EN 16139

601

SI NOTest results: a) Rotture di componenti o giunzioni x

x

b) Allentamenti di giunzioniSeat force!

N

x

c) No elemento strutturale importante notevolm. def.1.000 300 200.000 No defects d) Funzioni inalterate dopo rimoz. carichi x

Note: ApparecchiaturaThe test has been carried out according to table 1 of EN 16139:2013, level L2 - extreme.

pag. 1/1

The sample name and, when relevant, its description, are given by the orderer, and CATAS does not assume responsibility on this matter. This test report relates to the sample submitted for the test and no others. Additions, deletions or alterations are not permitted. This test report must always be reproduced in its entirety. Unless otherwise stated, sampling has been carried out by the orderer.

This document is validated by digital signature and time stamping in accordance with the Italian laws and the European Directives which regulate the electronic signature systems.

Managing Director Dr. Andrea Giavon

Page 7: SAMPLE N° 186033 - Meble-Bocian · PDF filevia ca' leoncino, 2 31030 castello di godego (tv) italia

TEST REPORT

186033 / 5Date received: 12/11/14Date of test: 04/12/14Date of issue: 13/01/15Sample name: BI

Seat front edge durability test EN 1728:2012+AC:2013

OMP S.R.L.!VIA CA' LEONCINO, 2!31030 CASTELLO DI GODEGO (TV)!ITALIA

CATAS S.p.A. Iscr. Reg. Imprese Udine nr. iscr. C.F. 01818850305 Reg. Impr. UD 20663 P. IVA : 01818850305 C.Soc. € 1.003.650,00 i.v.

centro ricerche-sviluppo e laboratori prove settori legno-arredo, ambiente e alimenti

Sede: Via Antica, 24/3 33048 S. Giovanni al Nat. UD Tel. 0432.747211 r.a. Fax 0432.747250 http://www.catas.com e-mail: [email protected]

Filiale: Via Braille, 5 20851 Lissone MB Tel. 039.464567 Fax 039.464565 e-mail: [email protected]

Seat front edge durability test clause 6.18

Seat force !N

Number of !cycles Remarks

EN 16139

573

SI NOTest results:a) Rotture di componenti o giunzioni

Points of !application

x

x

b) Allentamenti di giunzionix

100 mm back from!the front edge 800 100.000 No defects c) No elemento strutturale importante notevolm. def.

d) Funzioni inalterate dopo rimoz. carichi

Note:

x

ApparecchiaturaThe test has been carried out according to table 1 of EN 16139:2013, level L2 - extreme.

pag. 1/1

The sample name and, when relevant, its description, are given by the orderer, and CATAS does not assume responsibility on this matter. This test report relates to the sample submitted for the test and no others. Additions, deletions or alterations are not permitted. This test report must always be reproduced in its entirety. Unless otherwise stated, sampling has been carried out by the orderer.

This document is validated by digital signature and time stamping in accordance with the Italian laws and the European Directives which regulate the electronic signature systems.

Managing Director Dr. Andrea Giavon

Page 8: SAMPLE N° 186033 - Meble-Bocian · PDF filevia ca' leoncino, 2 31030 castello di godego (tv) italia

TEST REPORT

186033 / 6Date received: 12/11/14Date of test: 10/12/14Date of issue: 13/01/15Sample name: BI

Leg forward static load test EN 1728:2012+AC:2013

OMP S.R.L.!VIA CA' LEONCINO, 2!31030 CASTELLO DI GODEGO (TV)!ITALIA

CATAS S.p.A. Iscr. Reg. Imprese Udine nr. iscr. C.F. 01818850305 Reg. Impr. UD 20663 P. IVA : 01818850305 C.Soc. € 1.003.650,00 i.v.

centro ricerche-sviluppo e laboratori prove settori legno-arredo, ambiente e alimenti

Sede: Via Antica, 24/3 33048 S. Giovanni al Nat. UD Tel. 0432.747211 r.a. Fax 0432.747250 http://www.catas.com e-mail: [email protected]

Filiale: Via Braille, 5 20851 Lissone MB Tel. 039.464567 Fax 039.464565 e-mail: [email protected]

Leg forward static load test clause 6.15

Balancing!seat force!

NNumber!of cycles Remarks

EN 16139

SI NO

Test results:a) Rotture di componenti o giunzioni x

xb) Allentamenti di giunzioni xc) No elemento strutturale importante notevolm. def.

Forward!horizontal force!

N d) Funzioni inalterate dopo rimoz. carichix

620 1.800 10 No defects

ApparecchiaturaNote:The test has been carried out according to table 1 of EN 16139:2013, level L2 - extreme.

pag. 1/1

The sample name and, when relevant, its description, are given by the orderer, and CATAS does not assume responsibility on this matter. This test report relates to the sample submitted for the test and no others. Additions, deletions or alterations are not permitted. This test report must always be reproduced in its entirety. Unless otherwise stated, sampling has been carried out by the orderer.

This document is validated by digital signature and time stamping in accordance with the Italian laws and the European Directives which regulate the electronic signature systems.

Managing Director Dr. Andrea Giavon

Page 9: SAMPLE N° 186033 - Meble-Bocian · PDF filevia ca' leoncino, 2 31030 castello di godego (tv) italia

TEST REPORT

186033 / 7Date received: 12/11/14Date of test: 10/12/14Date of issue: 13/01/15Sample name: BI

Leg sideways static load test EN 1728:2012+AC:2013

OMP S.R.L.!VIA CA' LEONCINO, 2!31030 CASTELLO DI GODEGO (TV)!ITALIA

CATAS S.p.A. Iscr. Reg. Imprese Udine nr. iscr. C.F. 01818850305 Reg. Impr. UD 20663 P. IVA : 01818850305 C.Soc. € 1.003.650,00 i.v.

centro ricerche-sviluppo e laboratori prove settori legno-arredo, ambiente e alimenti

Sede: Via Antica, 24/3 33048 S. Giovanni al Nat. UD Tel. 0432.747211 r.a. Fax 0432.747250 http://www.catas.com e-mail: [email protected]

Filiale: Via Braille, 5 20851 Lissone MB Tel. 039.464567 Fax 039.464565 e-mail: [email protected]

Leg sideways static load test clause 6.16

Balancing!seat force!

NNumber!of cycles Remarks

EN 16139

SI NO

Test results:a) Rotture di componenti o giunzioni x

xb) Allentamenti di giunzioni xc) No elemento strutturale importante notevolm. def.

Sideways!horizontal force!

N d) Funzioni inalterate dopo rimoz. carichix

580 1.800 10 No defects

ApparecchiaturaNote:According to EN 1728:2012, horizontal force has been reduced from 760 N to 580 N, to avoid tipping.

The test has been carried out according to table 1 of EN 16139:2013, level L2 - extreme.

pag. 1/1

The sample name and, when relevant, its description, are given by the orderer, and CATAS does not assume responsibility on this matter. This test report relates to the sample submitted for the test and no others. Additions, deletions or alterations are not permitted. This test report must always be reproduced in its entirety. Unless otherwise stated, sampling has been carried out by the orderer.

This document is validated by digital signature and time stamping in accordance with the Italian laws and the European Directives which regulate the electronic signature systems.

Managing Director Dr. Andrea Giavon

Page 10: SAMPLE N° 186033 - Meble-Bocian · PDF filevia ca' leoncino, 2 31030 castello di godego (tv) italia

TEST REPORT

186033 / 8Date received: 12/11/14Date of test: 10/12/14Date of issue: 13/01/15Sample name: BI

Seat impact test EN 1728:2012+AC:2013

OMP S.R.L.!VIA CA' LEONCINO, 2!31030 CASTELLO DI GODEGO (TV)!ITALIA

CATAS S.p.A. Iscr. Reg. Imprese Udine nr. iscr. C.F. 01818850305 Reg. Impr. UD 20663 P. IVA : 01818850305 C.Soc. € 1.003.650,00 i.v.

centro ricerche-sviluppo e laboratori prove settori legno-arredo, ambiente e alimenti

Sede: Via Antica, 24/3 33048 S. Giovanni al Nat. UD Tel. 0432.747211 r.a. Fax 0432.747250 http://www.catas.com e-mail: [email protected]

Filiale: Via Braille, 5 20851 Lissone MB Tel. 039.464567 Fax 039.464565 e-mail: [email protected]

Seat impact test clause 6.24

Height!of drop!

mmNumber!of drops Remarks

EN 16139

SI NO

Test results:a) Rotture di componenti o giunzioni x

xb) Allentamenti di giunzioni xc) No elemento strutturale importante notevolm. def.

Mass of!impactor!

kgd) Funzioni inalterate dopo rimoz. carichi

x

25 300 10 No defects

ApparecchiaturaNote:The test has been carried out according to table 1 of EN 16139:2013, level L2 - extreme.

pag. 1/1

The sample name and, when relevant, its description, are given by the orderer, and CATAS does not assume responsibility on this matter. This test report relates to the sample submitted for the test and no others. Additions, deletions or alterations are not permitted. This test report must always be reproduced in its entirety. Unless otherwise stated, sampling has been carried out by the orderer.

This document is validated by digital signature and time stamping in accordance with the Italian laws and the European Directives which regulate the electronic signature systems.

Managing Director Dr. Andrea Giavon

Page 11: SAMPLE N° 186033 - Meble-Bocian · PDF filevia ca' leoncino, 2 31030 castello di godego (tv) italia

TEST REPORT

186033 / 9Date received: 12/11/14Date of test: 10/12/14Date of issue: 13/01/15Sample name: BI

Back impact test EN 1728:2012+AC:2013

OMP S.R.L.!VIA CA' LEONCINO, 2!31030 CASTELLO DI GODEGO (TV)!ITALIA

CATAS S.p.A. Iscr. Reg. Imprese Udine nr. iscr. C.F. 01818850305 Reg. Impr. UD 20663 P. IVA : 01818850305 C.Soc. € 1.003.650,00 i.v.

centro ricerche-sviluppo e laboratori prove settori legno-arredo, ambiente e alimenti

Sede: Via Antica, 24/3 33048 S. Giovanni al Nat. UD Tel. 0432.747211 r.a. Fax 0432.747250 http://www.catas.com e-mail: [email protected]

Filiale: Via Braille, 5 20851 Lissone MB Tel. 039.464567 Fax 039.464565 e-mail: [email protected]

Back impact test clause 6.25

Mass of!impactor!

kgNumber!of cycles Remarks

EN 16139

SI NO

Test results:a) Rotture di componenti o giunzioni x

xb) Allentamenti di giunzioni xc) No elemento strutturale importante notevolm. def.

Angle!°

d) Funzioni inalterate dopo rimoz. carichix

48 6,5 10 No defects

ApparecchiaturaNote:The test has been carried out according to table 1 of EN 16139:2013, level L2 - extreme.

pag. 1/1

The sample name and, when relevant, its description, are given by the orderer, and CATAS does not assume responsibility on this matter. This test report relates to the sample submitted for the test and no others. Additions, deletions or alterations are not permitted. This test report must always be reproduced in its entirety. Unless otherwise stated, sampling has been carried out by the orderer.

This document is validated by digital signature and time stamping in accordance with the Italian laws and the European Directives which regulate the electronic signature systems.

Managing Director Dr. Andrea Giavon

Page 12: SAMPLE N° 186033 - Meble-Bocian · PDF filevia ca' leoncino, 2 31030 castello di godego (tv) italia

TEST REPORT

186033 / 10Date received: 12/11/14Date of test: 10/12/14Date of issue: 13/01/15Sample name: BI

Stability - EN 1022:2005

OMP S.R.L.!VIA CA' LEONCINO, 2!31030 CASTELLO DI GODEGO (TV)!ITALIA

CATAS S.p.A. Iscr. Reg. Imprese Udine nr. iscr. C.F. 01818850305 Reg. Impr. UD 20663 P. IVA : 01818850305 C.Soc. € 1.003.650,00 i.v.

centro ricerche-sviluppo e laboratori prove settori legno-arredo, ambiente e alimenti

Sede: Via Antica, 24/3 33048 S. Giovanni al Nat. UD Tel. 0432.747211 r.a. Fax 0432.747250 http://www.catas.com e-mail: [email protected]

Filiale: Via Braille, 5 20851 Lissone MB Tel. 039.464567 Fax 039.464565 e-mail: [email protected]

Type of chair: fixed geometry

: 20 N does not overturn

Minimum horizontal force for rearwards overturning of fixed back chair: 163 N

Forwards overturning Horizontal force

Rearwards overturning

: 163 N does not overturn Fixed back chair Horizontal force

Tilting chair in the rearmost position: /

N does not overturn

Loading discs on the seat

Sideways overturning for chairs with arms: / Horizontal force

Sideways overturning for chairs without arms: 20 Horizontal force

Forwards overturning for chairs with footrest: / Horizontal force

Test passed

pag. 1/1

The sample name and, when relevant, its description, are given by the orderer, and CATAS does not assume responsibility on this matter. This test report relates to the sample submitted for the test and no others. Additions, deletions or alterations are not permitted. This test report must always be reproduced in its entirety. Unless otherwise stated, sampling has been carried out by the orderer.

This document is validated by digital signature and time stamping in accordance with the Italian laws and the European Directives which regulate the electronic signature systems.

Managing Director Dr. Andrea Giavon