23
HEMA-TEK (WRIGHT-GIEMSA) STAIN PAK Liquid. SAFETY DATA SHEET Product identifier Product type Section 1. Identification : : HEMA-TEK (WRIGHT-GIEMSA) STAIN PAK Relevant identified uses of the substance or mixture and uses advised against 4405.KIT (800) 424-9300 (CHEMTREC) (24/365) Manufactured/supplied : Siemens Healthcare Diagnostics Inc. 511 Benedict Avenue Tarrytown, NY 10591-5097 USA 1-877-229-3711 Product code : 4405.KIT, 10314755, 01178588 Not applicable. (2012 OSHA Hazard Communication Standard (29 CFR 1910.1200)) SDS # : Section 2. Hazards identification HEMA-TEK (WRIGHT-GIEMSA) BUFFER SOLUTION Not classified. HEMA-TEK (WRIGHT-GIEMSA) RINSE SOLUTION ACUTE TOXICITY (oral) - Category 4 SKIN SENSITIZATION - Category 1 SPECIFIC TARGET ORGAN TOXICITY (SINGLE EXPOSURE) - Category 2 HEMA-TEK (WRIGHT-GIEMSA) STAIN SOLUTION FLAMMABLE LIQUIDS - Category 2 ACUTE TOXICITY (oral) - Category 3 ACUTE TOXICITY (dermal) - Category 3 ACUTE TOXICITY (inhalation) - Category 3 SPECIFIC TARGET ORGAN TOXICITY (SINGLE EXPOSURE) - Category 1 Classification of the substance or mixture : Hazard pictograms : GHS label elements OSHA/HCS status : HEMA-TEK (WRIGHT-GIEMSA) BUFFER SOLUTION While this material is not considered hazardous by the OSHA Hazard Communication Standard (29 CFR 1910. 1200), this SDS contains valuable information critical to the safe handling and proper use of the product. This SDS should be retained and available for employees and other users of this product. HEMA-TEK (WRIGHT-GIEMSA) RINSE SOLUTION This material is considered hazardous by the OSHA Hazard Communication Standard (29 CFR 1910.1200). HEMA-TEK (WRIGHT-GIEMSA) STAIN SOLUTION This material is considered hazardous by the OSHA Hazard Communication Standard (29 CFR 1910.1200). Not available. Not available. Additional information : Date of issue/Date of revision : 4/1/2020 Date of previous issue : 12/13/2018 Version : 1.08 1/23

SAFETY DATA SHEET · 2020. 7. 27. · HEMA-TEK (WRIGHT-GIEMSA) STAIN SOLUTION P280 - Wear protective gloves/protective clothing/eye protection/face protection. P210 - Keep away from

  • Upload
    others

  • View
    5

  • Download
    0

Embed Size (px)

Citation preview

  • HEMA-TEK (WRIGHT-GIEMSA) STAIN PAK

    Liquid.

    SAFETY DATA SHEET

    Product identifier

    Product type

    Section 1. Identification:

    :

    HEMA-TEK (WRIGHT-GIEMSA) STAIN PAK

    Relevant identified uses of the substance or mixture and uses advised against

    4405.KIT

    (800) 424-9300 (CHEMTREC) (24/365)

    Manufactured/supplied : Siemens Healthcare Diagnostics Inc.511 Benedict AvenueTarrytown, NY 10591-5097 USA1-877-229-3711

    Product code : 4405.KIT, 10314755, 01178588

    Not applicable.

    (2012 OSHA Hazard Communication Standard (29 CFR 1910.1200))

    SDS # :

    Section 2. Hazards identification

    HEMA-TEK (WRIGHT-GIEMSA) BUFFER SOLUTION

    Not classified.

    HEMA-TEK (WRIGHT-GIEMSA) RINSE SOLUTION

    ACUTE TOXICITY (oral) - Category 4

    SKIN SENSITIZATION - Category 1SPECIFIC TARGET ORGAN TOXICITY (SINGLE EXPOSURE) - Category 2

    HEMA-TEK (WRIGHT-GIEMSA) STAIN SOLUTION

    FLAMMABLE LIQUIDS - Category 2

    ACUTE TOXICITY (oral) - Category 3ACUTE TOXICITY (dermal) - Category 3ACUTE TOXICITY (inhalation) - Category 3SPECIFIC TARGET ORGAN TOXICITY (SINGLE EXPOSURE) - Category 1

    Classification of the substance or mixture

    :

    Hazard pictograms :

    GHS label elements

    OSHA/HCS status : HEMA-TEK (WRIGHT-GIEMSA) BUFFER SOLUTION

    While this material is not considered hazardous by the OSHA Hazard Communication Standard (29 CFR 1910.1200), this SDS contains valuable information critical to the safe handling and proper use of the product. This SDS should be retained and available for employees and other users of this product.

    HEMA-TEK (WRIGHT-GIEMSA) RINSE SOLUTION

    This material is considered hazardous by the OSHA Hazard Communication Standard (29 CFR 1910.1200).

    HEMA-TEK (WRIGHT-GIEMSA) STAIN SOLUTION

    This material is considered hazardous by the OSHA Hazard Communication Standard (29 CFR 1910.1200).

    Not available.

    Not available.

    Additional information :

    Date of issue/Date of revision : 4/1/2020 Date of previous issue : 12/13/2018 Version : 1.08 1/23

  • HEMA-TEK (WRIGHT-GIEMSA) STAIN PAK

    Section 2. Hazards identificationSignal word : HEMA-TEK (WRIGHT-GIEMSA) BUFFER

    SOLUTIONNo signal word.

    HEMA-TEK (WRIGHT-GIEMSA) RINSE SOLUTION

    Warning

    HEMA-TEK (WRIGHT-GIEMSA) STAIN SOLUTION

    Danger

    Hazard statements : HEMA-TEK (WRIGHT-GIEMSA) BUFFER SOLUTION

    No known significant effects or critical hazards.

    HEMA-TEK (WRIGHT-GIEMSA) RINSE SOLUTION

    H302 - Harmful if swallowed.

    H317 - May cause an allergic skin reaction.H371 - May cause damage to organs.

    HEMA-TEK (WRIGHT-GIEMSA) STAIN SOLUTION

    H225 - Highly flammable liquid and vapor.

    H301 + H311 + H331 - Toxic if swallowed,in contact with skin or if inhaled.H370 - Causes damage to organs.

    Precautionary statements

    Prevention : HEMA-TEK (WRIGHT-GIEMSA) BUFFER SOLUTION

    Not applicable.

    HEMA-TEK (WRIGHT-GIEMSA) RINSE SOLUTION

    P260 - Do not breathe vapor.

    P264 - Wash hands thoroughly after handling.P280 - Wear protective gloves/protective clothing/eye protection/face protection.P272 - Contaminated work clothing should not be allowed out of the workplace.

    HEMA-TEK (WRIGHT-GIEMSA) STAIN SOLUTION

    P280 - Wear protective gloves/protective clothing/eye protection/face protection.P210 - Keep away from heat, sparks,open flames and hot surfaces. - No smoking.P260 - Do not breathe vapor.P235 - Keep cool.

    Response : HEMA-TEK (WRIGHT-GIEMSA) BUFFER SOLUTION

    Not applicable.

    HEMA-TEK (WRIGHT-GIEMSA) RINSE SOLUTION

    P308 + P311 - IF exposed or concerned:Call a POISON CENTER or physician.P301 + P312 + P330 - IF SWALLOWED:Call a POISON CENTER or physician if you feel unwell. Rinse mouth.P302 + P352 + P363 - IF ON SKIN: Wash with plenty of soap and water. Wash contaminated clothing before reuse.P333 + P313 - If skin irritation or rash occurs: Get medical attention.

    HEMA-TEK (WRIGHT-GIEMSA) STAIN SOLUTION

    P304 - IF INHALED:

    P340 - Remove victim to fresh air and keep at rest in a position comfortable for breathing.P301 - IF SWALLOWED:P310 - Immediately call a POISON CENTER or physician.P303 - IF ON SKIN (or hair):P361 - Take off immediately all contaminated clothing.P353 - Rinse skin with water or shower.

    Storage : HEMA-TEK (WRIGHT-GIEMSA) BUFFER SOLUTION

    Not applicable.

    HEMA-TEK (WRIGHT-GIEMSA) RINSE SOLUTION

    P405 - Store locked up.

    HEMA-TEK (WRIGHT-GIEMSA) STAIN SOLUTION

    Not applicable.

    Date of issue/Date of revision : 4/1/2020 Date of previous issue : 12/13/2018 Version : 1.08 2/23

  • HEMA-TEK (WRIGHT-GIEMSA) STAIN PAK

    Section 2. Hazards identificationDisposal : HEMA-TEK (WRIGHT-GIEMSA) BUFFER

    SOLUTIONNot applicable.

    HEMA-TEK (WRIGHT-GIEMSA) RINSE SOLUTION

    P501 - Dispose of contents and container in accordance with all local, regional, and national regulations.

    HEMA-TEK (WRIGHT-GIEMSA) STAIN SOLUTION

    P501 - Dispose of contents and container in accordance with all local, regional, and national regulations.

    Supplemental label elements

    : HEMA-TEK (WRIGHT-GIEMSA) BUFFER SOLUTION

    None known.

    HEMA-TEK (WRIGHT-GIEMSA) RINSE SOLUTION

    None known.

    HEMA-TEK (WRIGHT-GIEMSA) STAIN SOLUTION

    None known.

    Hazards not otherwise classified

    : HEMA-TEK (WRIGHT-GIEMSA) BUFFER SOLUTION

    None known.

    HEMA-TEK (WRIGHT-GIEMSA) RINSE SOLUTION

    None known.

    HEMA-TEK (WRIGHT-GIEMSA) STAIN SOLUTION

    None known.

    Section 3. Composition/information on ingredients

    HEMA-TEK (WRIGHT-GIEMSA) RINSE SOLUTIONmethanol 7.845 67-56-1reaction mass of: 5-chloro-2-methyl-4-isothiazolin-3-one [EC no. 247-500-7]and 2-methyl-2H-isothiazol-3-one [EC no. 220-239-6] (3:1)

    0.003708 55965-84-9

    HEMA-TEK (WRIGHT-GIEMSA) STAIN SOLUTIONmethanol 97.792 67-56-1Poly(oxy-1,2-ethanediyl), α-[4-(1,1,3,3-tetramethylbutyl)phenyl]-ω-hydroxy- 1.339 9002-93-1

    Ingredient name CAS number%

    There are no additional ingredients present which, within the current knowledge of the supplier and in the concentrations applicable, are classified as hazardous to health or the environment and hence require reporting in this section.

    Substance/mixture :

    Occupational exposure limits, if available, are listed in Section 8.

    HEMA-TEK (WRIGHT-GIEMSA) BUFFER SOLUTION

    Mixture

    HEMA-TEK (WRIGHT-GIEMSA) RINSE SOLUTION

    Mixture

    HEMA-TEK (WRIGHT-GIEMSA) STAIN SOLUTION

    Mixture

    Any concentration shown as a range is to protect confidentiality or is due to batch variation.

    HEMA-TEK (WRIGHT-GIEMSA) BUFFER SOLUTION

    Immediately flush eyes with plenty of water, occasionally lifting the upper and lower eyelids. Check for and remove any contact lenses. Get medical attention if irritation occurs.

    HEMA-TEK (WRIGHT-GIEMSA) RINSE SOLUTION

    Immediately flush eyes with plenty of water, occasionally lifting the upper and lower eyelids. Check for and remove any contact lenses. Continue to rinse for at least 10 minutes. Get medical attention following exposure or if feeling unwell. If necessary, call a poison center or physician.

    HEMA-TEK (WRIGHT-GIEMSA) STAIN SOLUTION

    Immediately flush eyes with plenty of water, occasionally lifting the upper and lower eyelids. Check for and remove any

    Section 4. First aid measures

    Eye contact :

    Description of necessary first aid measures

    Date of issue/Date of revision : 4/1/2020 Date of previous issue : 12/13/2018 Version : 1.08 3/23

  • HEMA-TEK (WRIGHT-GIEMSA) STAIN PAK

    Section 4. First aid measurescontact lenses. Continue to rinse for at least 10 minutes. Get medical attention.If necessary, call a poison center or physician.

    HEMA-TEK (WRIGHT-GIEMSA) BUFFER SOLUTION

    Flush contaminated skin with plenty of water. Remove contaminated clothing and shoes. Get medical attention if symptoms occur.

    HEMA-TEK (WRIGHT-GIEMSA) RINSE SOLUTION

    Wash with plenty of soap and water.Remove contaminated clothing and shoes.Wash contaminated clothing thoroughly with water before removing it, or wear gloves. Continue to rinse for at least 10 minutes. Get medical attention. If necessary, call a poison center or physician. In the event of any complaints or symptoms, avoid further exposure.Wash clothing before reuse. Clean shoes thoroughly before reuse.

    HEMA-TEK (WRIGHT-GIEMSA) STAIN SOLUTION

    Wash with plenty of soap and water.Remove contaminated clothing and shoes.Wash contaminated clothing thoroughly with water before removing it, or wear gloves. Continue to rinse for at least 10 minutes. Get medical attention. If necessary, call a poison center or physician. Wash clothing before reuse.Clean shoes thoroughly before reuse.

    HEMA-TEK (WRIGHT-GIEMSA) BUFFER SOLUTION

    Remove victim to fresh air and keep at rest in a position comfortable for breathing.Get medical attention if symptoms occur.

    HEMA-TEK (WRIGHT-GIEMSA) RINSE SOLUTION

    Remove victim to fresh air and keep at rest in a position comfortable for breathing.If not breathing, if breathing is irregular or if respiratory arrest occurs, provide artificial respiration or oxygen by trained personnel. It may be dangerous to the person providing aid to give mouth-to-mouth resuscitation. Get medical attention following exposure or if feeling unwell. If necessary, call a poison center or physician. If unconscious, place in recovery position and get medical attention immediately. Maintain an open airway. Loosen tight clothing such as a collar, tie, belt or waistband.

    HEMA-TEK (WRIGHT-GIEMSA) STAIN SOLUTION

    Remove victim to fresh air and keep at rest in a position comfortable for breathing.If it is suspected that fumes are still present, the rescuer should wear an appropriate mask or self-contained breathing apparatus. If not breathing, if breathing is irregular or if respiratory arrest occurs, provide artificial respiration or oxygen by trained personnel. It may be dangerous to the person providing aid to give mouth-to-mouth resuscitation. Get medical attention. If necessary, call a poison center or physician. If unconscious,place in recovery position and get medical attention immediately. Maintain an open airway. Loosen tight clothing such as a collar, tie, belt or waistband.

    Skin contact

    Inhalation

    :

    :

    Date of issue/Date of revision : 4/1/2020 Date of previous issue : 12/13/2018 Version : 1.08 4/23

  • HEMA-TEK (WRIGHT-GIEMSA) STAIN PAK

    Section 4. First aid measuresHEMA-TEK (WRIGHT-GIEMSA) BUFFER SOLUTION

    Wash out mouth with water. Remove victim to fresh air and keep at rest in a position comfortable for breathing. If material has been swallowed and the exposed person is conscious, give small quantities of water to drink. Do not induce vomiting unless directed to do so by medical personnel. Get medical attention if symptoms occur.

    HEMA-TEK (WRIGHT-GIEMSA) RINSE SOLUTION

    Wash out mouth with water. Remove dentures if any. Remove victim to fresh air and keep at rest in a position comfortable for breathing. If material has been swallowed and the exposed person is conscious, give small quantities of water to drink. Stop if the exposed person feels sick as vomiting may be dangerous. Do not induce vomiting unless directed to do so by medical personnel. If vomiting occurs, the head should be kept low so that vomit does not enter the lungs. Get medical attention. If necessary, call a poison center or physician. Never give anything by mouth to an unconscious person. If unconscious, place in recovery position and get medical attention immediately. Maintain an open airway.Loosen tight clothing such as a collar, tie,belt or waistband.

    HEMA-TEK (WRIGHT-GIEMSA) STAIN SOLUTION

    Get medical attention immediately. Call a poison center or physician. Wash out mouth with water. Remove dentures if any. Remove victim to fresh air and keep at rest in a position comfortable for breathing. If material has been swallowed and the exposed person is conscious, give small quantities of water to drink. Stop if the exposed person feels sick as vomiting may be dangerous. Do not induce vomiting unless directed to do so by medical personnel. If vomiting occurs, the head should be kept low so that vomit does not enter the lungs. Never give anything by mouth to an unconscious person. If unconscious, place in recovery position and get medical attention immediately. Maintain an open airway.Loosen tight clothing such as a collar, tie,belt or waistband.

    Ingestion :

    Most important symptoms/effects, acute and delayed

    Inhalation : HEMA-TEK (WRIGHT-GIEMSA) BUFFER SOLUTION

    No known significant effects or critical hazards.

    HEMA-TEK (WRIGHT-GIEMSA) RINSE SOLUTION

    No known significant effects or critical hazards.

    HEMA-TEK (WRIGHT-GIEMSA) STAIN SOLUTION

    Toxic if inhaled.

    HEMA-TEK (WRIGHT-GIEMSA) BUFFER SOLUTION

    No known significant effects or critical hazards.

    HEMA-TEK (WRIGHT-GIEMSA) RINSE SOLUTION

    No known significant effects or critical hazards.

    HEMA-TEK (WRIGHT-GIEMSA) STAIN SOLUTION

    No known significant effects or critical hazards.

    :Eye contact

    Potential acute health effects

    Date of issue/Date of revision : 4/1/2020 Date of previous issue : 12/13/2018 Version : 1.08 5/23

  • HEMA-TEK (WRIGHT-GIEMSA) STAIN PAK

    Section 4. First aid measures

    Protection of first-aiders : No action shall be taken involving any personal risk or without suitable training. If it is suspected that fumes are still present, the rescuer should wear an appropriate mask or self-contained breathing apparatus. It may be dangerous to the person providing aid to give mouth-to-mouth resuscitation. Wash contaminated clothing thoroughly with water before removing it, or wear gloves.

    Notes to physician : Treat symptomatically. Contact poison treatment specialist immediately if large quantities have been ingested or inhaled.

    Specific treatments : No specific treatment.

    HEMA-TEK (WRIGHT-GIEMSA) BUFFER SOLUTION

    No known significant effects or critical hazards.

    HEMA-TEK (WRIGHT-GIEMSA) RINSE SOLUTION

    Harmful if swallowed.

    HEMA-TEK (WRIGHT-GIEMSA) STAIN SOLUTION

    Toxic if swallowed.

    :Ingestion

    Skin contact : HEMA-TEK (WRIGHT-GIEMSA) BUFFER SOLUTION

    No known significant effects or critical hazards.

    HEMA-TEK (WRIGHT-GIEMSA) RINSE SOLUTION

    May cause an allergic skin reaction.

    HEMA-TEK (WRIGHT-GIEMSA) STAIN SOLUTION

    Toxic in contact with skin.

    Over-exposure signs/symptoms

    Skin contact

    Ingestion

    Inhalation HEMA-TEK (WRIGHT-GIEMSA) BUFFER SOLUTION

    No specific data.

    HEMA-TEK (WRIGHT-GIEMSA) RINSE SOLUTION

    No specific data.

    HEMA-TEK (WRIGHT-GIEMSA) STAIN SOLUTION

    No specific data.

    HEMA-TEK (WRIGHT-GIEMSA) BUFFER SOLUTION

    No specific data.

    HEMA-TEK (WRIGHT-GIEMSA) RINSE SOLUTION

    No specific data.

    HEMA-TEK (WRIGHT-GIEMSA) STAIN SOLUTION

    No specific data.

    HEMA-TEK (WRIGHT-GIEMSA) BUFFER SOLUTION

    No specific data.

    HEMA-TEK (WRIGHT-GIEMSA) RINSE SOLUTION

    Adverse symptoms may include the following:irritationredness

    HEMA-TEK (WRIGHT-GIEMSA) STAIN SOLUTION

    No specific data.

    :

    :

    :

    Eye contact : HEMA-TEK (WRIGHT-GIEMSA) BUFFER SOLUTION

    No specific data.

    HEMA-TEK (WRIGHT-GIEMSA) RINSE SOLUTION

    No specific data.

    HEMA-TEK (WRIGHT-GIEMSA) STAIN SOLUTION

    No specific data.

    See toxicological information (Section 11)

    Indication of immediate medical attention and special treatment needed, if necessary

    Section 5. Fire-fighting measures

    Specific hazards arising from the chemical

    In a fire or if heated, a pressure increase will occur and the container may burst.

    Extinguishing media

    :

    None known.

    Suitable extinguishing media

    :

    Unsuitable extinguishing media

    :

    In case of fire, use water spray (fog), foam or dry chemical.

    Date of issue/Date of revision : 4/1/2020 Date of previous issue : 12/13/2018 Version : 1.08 6/23

  • HEMA-TEK (WRIGHT-GIEMSA) STAIN PAK

    Section 5. Fire-fighting measures

    Promptly isolate the scene by removing all persons from the vicinity of the incident if there is a fire. No action shall be taken involving any personal risk or without suitable training.

    Hazardous thermal decomposition products

    Decomposition products may include the following materials:carbon dioxidecarbon monoxide

    Fire-fighters should wear appropriate protective equipment and self-contained breathing apparatus (SCBA) with a full face-piece operated in positive pressure mode.

    Special protective equipment for fire-fighters

    :

    :

    Special protective actions for fire-fighters

    :

    Section 6. Accidental release measures

    Environmental precautions

    Personal precautions, protective equipment and emergency procedures

    Stop leak if without risk. Move containers from spill area. Approach release from upwind. Prevent entry into sewers, water courses, basements or confined areas.Wash spillages into an effluent treatment plant or proceed as follows. Contain and collect spillage with non-combustible, absorbent material e.g. sand, earth, vermiculite or diatomaceous earth and place in container for disposal according to local regulations (see Section 13). Dispose of via a licensed waste disposal contractor. Contaminated absorbent material may pose the same hazard as the spilled product. Note: see Section 1 for emergency contact information and Section 13 for waste disposal.

    :

    : No action shall be taken involving any personal risk or without suitable training.Evacuate surrounding areas. Keep unnecessary and unprotected personnel from entering. Do not touch or walk through spilled material. Avoid breathing vapor or mist.Provide adequate ventilation. Wear appropriate respirator when ventilation is inadequate. Put on appropriate personal protective equipment.

    Avoid dispersal of spilled material and runoff and contact with soil, waterways, drains and sewers. Inform the relevant authorities if the product has caused environmental pollution (sewers, waterways, soil or air).

    Large spill :

    Stop leak if without risk. Move containers from spill area. Dilute with water and mop up if water-soluble. Alternatively, or if water-insoluble, absorb with an inert dry material and place in an appropriate waste disposal container. Dispose of via a licensed waste disposal contractor.

    Small spill :

    Methods and materials for containment and cleaning up

    For non-emergency personnel

    For emergency responders : If specialized clothing is required to deal with the spillage, take note of any information in Section 8 on suitable and unsuitable materials. See also the information in "For non-emergency personnel".

    Section 7. Handling and storage

    Advice on general occupational hygiene

    Conditions for safe storage,including any incompatibilities

    Eating, drinking and smoking should be prohibited in areas where this material is handled, stored and processed. Workers should wash hands and face before eating,drinking and smoking. Remove contaminated clothing and protective equipment before entering eating areas. See also Section 8 for additional information on hygiene measures.

    Store in accordance with local regulations. Store in original container protected from direct sunlight in a dry, cool and well-ventilated area, away from incompatible materials (see Section 10) and food and drink. Store locked up. Keep container tightly closed and sealed until ready for use. Containers that have been opened must be carefully resealed and kept upright to prevent leakage. Do not store in unlabeled containers.Use appropriate containment to avoid environmental contamination.

    :

    :

    Protective measures Put on appropriate personal protective equipment (see Section 8). Persons with a history of skin sensitization problems should not be employed in any process in which this product is used. Do not get in eyes or on skin or clothing. Do not breathe vapor or mist. Do not ingest. Use only with adequate ventilation. Wear appropriate respirator when ventilation is inadequate. Keep in the original container or an approved alternative made from a compatible material, kept tightly closed when not in use.Empty containers retain product residue and can be hazardous. Do not reuse container.

    :

    Precautions for safe handling

    Date of issue/Date of revision : 4/1/2020 Date of previous issue : 12/13/2018 Version : 1.08 7/23

  • HEMA-TEK (WRIGHT-GIEMSA) STAIN PAK

    HEMA-TEK (WRIGHT-GIEMSA) RINSE SOLUTIONmethanol ACGIH TLV (United States, 3/2015).

    Absorbed through skin. STEL: 328 mg/m³ 15 minutes. STEL: 250 ppm 15 minutes. TWA: 262 mg/m³ 8 hours. TWA: 200 ppm 8 hours.NIOSH REL (United States, 10/2013).Absorbed through skin. STEL: 325 mg/m³ 15 minutes. STEL: 250 ppm 15 minutes. TWA: 260 mg/m³ 10 hours. TWA: 200 ppm 10 hours.OSHA PEL (United States, 2/2013). TWA: 260 mg/m³ 8 hours. TWA: 200 ppm 8 hours.OSHA PEL 1989 (United States, 3/1989).Absorbed through skin. STEL: 325 mg/m³ 15 minutes. STEL: 250 ppm 15 minutes. TWA: 260 mg/m³ 8 hours. TWA: 200 ppm 8 hours.

    HEMA-TEK (WRIGHT-GIEMSA) STAIN SOLUTIONmethanol ACGIH TLV (United States, 3/2015).

    Absorbed through skin. STEL: 328 mg/m³ 15 minutes. STEL: 250 ppm 15 minutes. TWA: 262 mg/m³ 8 hours. TWA: 200 ppm 8 hours.NIOSH REL (United States, 10/2013).Absorbed through skin. STEL: 325 mg/m³ 15 minutes. STEL: 250 ppm 15 minutes. TWA: 260 mg/m³ 10 hours. TWA: 200 ppm 10 hours.OSHA PEL (United States, 2/2013). TWA: 260 mg/m³ 8 hours. TWA: 200 ppm 8 hours.OSHA PEL 1989 (United States, 3/1989).Absorbed through skin. STEL: 325 mg/m³ 15 minutes. STEL: 250 ppm 15 minutes. TWA: 260 mg/m³ 8 hours. TWA: 200 ppm 8 hours.

    Section 8. Exposure controls/personal protection

    Ingredient name Exposure limits

    Environmental exposure controls

    : Emissions from ventilation or work process equipment should be checked to ensure they comply with the requirements of environmental protection legislation. In some cases, fume scrubbers, filters or engineering modifications to the process equipment will be necessary to reduce emissions to acceptable levels.

    Appropriate engineering controls

    : Use only with adequate ventilation. Use process enclosures, local exhaust ventilation or other engineering controls to keep worker exposure to airborne contaminants below any recommended or statutory limits.

    Control parameters

    Individual protection measures

    Occupational exposure limits

    Date of issue/Date of revision : 4/1/2020 Date of previous issue : 12/13/2018 Version : 1.08 8/23

  • HEMA-TEK (WRIGHT-GIEMSA) STAIN PAK

    Section 8. Exposure controls/personal protection

    Hand protection

    Based on the hazard and potential for exposure, select a respirator that meets the appropriate standard or certification. Respirators must be used according to a respiratory protection program to ensure proper fitting, training, and other important aspects of use.

    Chemical-resistant, impervious gloves complying with an approved standard should be worn at all times when handling chemical products if a risk assessment indicates this is necessary. Considering the parameters specified by the glove manufacturer, check during use that the gloves are still retaining their protective properties. It should be noted that the time to breakthrough for any glove material may be different for different glove manufacturers. In the case of mixtures, consisting of several substances, the protection time of the gloves cannot be accurately estimated.

    Safety eyewear complying with an approved standard should be used when a risk assessment indicates this is necessary to avoid exposure to liquid splashes, mists,gases or dusts. If contact is possible, the following protection should be worn, unless the assessment indicates a higher degree of protection: safety glasses with side-shields.

    Eye/face protection

    Respiratory protection :

    :

    :

    Body protection Personal protective equipment for the body should be selected based on the task being performed and the risks involved and should be approved by a specialist before handling this product.

    :

    Wash hands, forearms and face thoroughly after handling chemical products, before eating, smoking and using the lavatory and at the end of the working period.Appropriate techniques should be used to remove potentially contaminated clothing.Contaminated work clothing should not be allowed out of the workplace. Wash contaminated clothing before reusing. Ensure that eyewash stations and safety showers are close to the workstation location.

    Hygiene measures :

    Skin protection

    Other skin protection : Appropriate footwear and any additional skin protection measures should be selected based on the task being performed and the risks involved and should be approved by a specialist before handling this product.

    Section 9. Physical and chemical propertiesPhysical state HEMA-TEK (WRIGHT-GIEMSA) BUFFER

    SOLUTIONLiquid.

    HEMA-TEK (WRIGHT-GIEMSA) RINSE SOLUTION

    Liquid.

    HEMA-TEK (WRIGHT-GIEMSA) STAIN SOLUTION

    Liquid.

    HEMA-TEK (WRIGHT-GIEMSA) BUFFER SOLUTION

    Bland.

    HEMA-TEK (WRIGHT-GIEMSA) RINSE SOLUTION

    Bland.

    HEMA-TEK (WRIGHT-GIEMSA) STAIN SOLUTION

    Characteristic.

    Odor

    pH

    HEMA-TEK (WRIGHT-GIEMSA) BUFFER SOLUTION

    Clear.Colorless.

    HEMA-TEK (WRIGHT-GIEMSA) RINSE SOLUTION

    Clear.Colorless.

    HEMA-TEK (WRIGHT-GIEMSA) STAIN SOLUTION

    Blue. [Dark]

    Color

    Flash point HEMA-TEK (WRIGHT-GIEMSA) BUFFER SOLUTION

    [Product does not sustain combustion.]

    HEMA-TEK (WRIGHT-GIEMSA) RINSE SOLUTION

    Not available.

    HEMA-TEK (WRIGHT-GIEMSA) STAIN SOLUTION

    Closed cup: 11°C (51.8°F)

    HEMA-TEK (WRIGHT-GIEMSA) BUFFER SOLUTION

    6.75 to 6.85

    HEMA-TEK (WRIGHT-GIEMSA) RINSE SOLUTION

    6.75 to 6.85

    HEMA-TEK (WRIGHT-GIEMSA) STAIN SOLUTION

    Not available.

    :

    :

    :

    :

    :

    Date of issue/Date of revision : 4/1/2020 Date of previous issue : 12/13/2018 Version : 1.08 9/23

  • HEMA-TEK (WRIGHT-GIEMSA) STAIN PAK

    Section 9. Physical and chemical properties

    Relative density HEMA-TEK (WRIGHT-GIEMSA) BUFFER SOLUTION

    1

    HEMA-TEK (WRIGHT-GIEMSA) RINSE SOLUTION

    1

    HEMA-TEK (WRIGHT-GIEMSA) STAIN SOLUTION

    Not relevant/applicable due to nature of the product.

    Auto-ignition temperature HEMA-TEK (WRIGHT-GIEMSA) BUFFER SOLUTION

    Not available.

    HEMA-TEK (WRIGHT-GIEMSA) RINSE SOLUTION

    Not available.

    HEMA-TEK (WRIGHT-GIEMSA) STAIN SOLUTION

    Not available.

    HEMA-TEK (WRIGHT-GIEMSA) BUFFER SOLUTION

    Not available.

    HEMA-TEK (WRIGHT-GIEMSA) RINSE SOLUTION

    Not available.

    HEMA-TEK (WRIGHT-GIEMSA) STAIN SOLUTION

    Not available.

    Viscosity HEMA-TEK (WRIGHT-GIEMSA) BUFFER SOLUTION

    Not available.

    HEMA-TEK (WRIGHT-GIEMSA) RINSE SOLUTION

    Not available.

    HEMA-TEK (WRIGHT-GIEMSA) STAIN SOLUTION

    Not available.

    Partition coefficient: n-octanol/water

    :

    :

    :

    :

    Flammability (solid, gas) : HEMA-TEK (WRIGHT-GIEMSA) BUFFER SOLUTION

    Not relevant/applicable due to nature of the product.

    HEMA-TEK (WRIGHT-GIEMSA) RINSE SOLUTION

    Not relevant/applicable due to nature of the product.

    HEMA-TEK (WRIGHT-GIEMSA) STAIN SOLUTION

    Not relevant/applicable due to nature of the product.

    Type of aerosol : HEMA-TEK (WRIGHT-GIEMSA) BUFFER SOLUTION

    Not applicable.

    HEMA-TEK (WRIGHT-GIEMSA) RINSE SOLUTION

    Not applicable.

    HEMA-TEK (WRIGHT-GIEMSA) STAIN SOLUTION

    Not applicable.

    Aerosol product

    Solubility in water : HEMA-TEK (WRIGHT-GIEMSA) BUFFER SOLUTION

    Not relevant/applicable due to nature of the product.

    HEMA-TEK (WRIGHT-GIEMSA) RINSE SOLUTION

    Not relevant/applicable due to nature of the product.

    HEMA-TEK (WRIGHT-GIEMSA) STAIN SOLUTION

    Not relevant/applicable due to nature of the product.

    Section 10. Stability and reactivity

    HEMA-TEK (WRIGHT-GIEMSA) BUFFER SOLUTION

    The product is stable.

    HEMA-TEK (WRIGHT-GIEMSA) RINSE SOLUTION

    The product is stable.

    HEMA-TEK (WRIGHT-GIEMSA) STAIN SOLUTION

    The product is stable.

    Chemical stability :

    Possibility of hazardous reactions

    : Under normal conditions of storage and use, hazardous reactions will not occur.

    Reactivity : HEMA-TEK (WRIGHT-GIEMSA) BUFFER SOLUTION

    No specific test data related to reactivity available for this product or its ingredients.

    HEMA-TEK (WRIGHT-GIEMSA) RINSE SOLUTION

    No specific test data related to reactivity available for this product or its ingredients.

    HEMA-TEK (WRIGHT-GIEMSA) STAIN SOLUTION

    No specific test data related to reactivity available for this product or its ingredients.

    Date of issue/Date of revision : 4/1/2020 Date of previous issue : 12/13/2018 Version : 1.08 10/23

  • HEMA-TEK (WRIGHT-GIEMSA) STAIN PAK

    Section 10. Stability and reactivity

    Hazardous decomposition products

    Conditions to avoid HEMA-TEK (WRIGHT-GIEMSA) BUFFER SOLUTION

    No specific data.

    HEMA-TEK (WRIGHT-GIEMSA) RINSE SOLUTION

    No specific data.

    HEMA-TEK (WRIGHT-GIEMSA) STAIN SOLUTION

    Avoid all possible sources of ignition (spark or flame). Do not pressurize, cut,weld, braze, solder, drill, grind or expose containers to heat or sources of ignition.

    HEMA-TEK (WRIGHT-GIEMSA) BUFFER SOLUTION

    Under normal conditions of storage and use, hazardous decomposition products should not be produced.

    HEMA-TEK (WRIGHT-GIEMSA) RINSE SOLUTION

    Under normal conditions of storage and use, hazardous decomposition products should not be produced.

    HEMA-TEK (WRIGHT-GIEMSA) STAIN SOLUTION

    Under normal conditions of storage and use, hazardous decomposition products should not be produced.

    HEMA-TEK (WRIGHT-GIEMSA) BUFFER SOLUTION

    No specific data.

    HEMA-TEK (WRIGHT-GIEMSA) RINSE SOLUTION

    No specific data.

    HEMA-TEK (WRIGHT-GIEMSA) STAIN SOLUTION

    Reactive or incompatible with the following materials:oxidizing materials

    :

    :

    Incompatible materials :

    Section 11. Toxicological information

    Acute toxicity

    HEMA-TEK (WRIGHT-GIEMSA) RINSE SOLUTIONmethanol LC50 Inhalation Gas. Rat 145000 ppm 1 hours

    LC50 Inhalation Gas. Rat 64000 ppm 4 hoursLD50 Dermal Rabbit 15800 mg/kg -LD50 Oral Rat 5600 mg/kg -

    reaction mass of: 5-chloro-2-methyl-4-isothiazolin-3-one [EC no. 247-500-7] and 2-methyl-2H-isothiazol-3-one [EC no. 220-239-6] (3:1)

    LD50 Oral Rat 53 mg/kg -

    HEMA-TEK (WRIGHT-GIEMSA) STAIN SOLUTIONmethanol LC50 Inhalation Gas. Rat 145000 ppm 1 hours

    LC50 Inhalation Gas. Rat 64000 ppm 4 hoursLD50 Dermal Rabbit 15800 mg/kg -LD50 Oral Rat 5600 mg/kg -

    Product/ingredient name Result Species Dose Exposure

    Conclusion/Summary : HEMA-TEK (WRIGHT-GIEMSA) BUFFER SOLUTION

    Not available.

    HEMA-TEK (WRIGHT-GIEMSA) RINSE SOLUTION

    Not available.

    HEMA-TEK (WRIGHT-GIEMSA) STAIN SOLUTION

    Not available.

    Irritation/Corrosion

    Information on toxicological effects

    Date of issue/Date of revision : 4/1/2020 Date of previous issue : 12/13/2018 Version : 1.08 11/23

  • HEMA-TEK (WRIGHT-GIEMSA) STAIN PAK

    Section 11. Toxicological information

    Mutagenicity

    Not available.

    HEMA-TEK (WRIGHT-GIEMSA) RINSE SOLUTIONmethanol Eyes - Moderate irritant Rabbit - 24 hours 100

    milligrams-

    Eyes - Moderate irritant Rabbit - 40 milligrams -Skin - Moderate irritant Rabbit - 24 hours 20

    milligrams-

    reaction mass of: 5-chloro-2-methyl-4-isothiazolin-3-one [EC no. 247-500-7] and 2-methyl-2H-isothiazol-3-one [EC no. 220-239-6] (3:1)

    Skin - Severe irritant Human - 0.01 Percent -

    HEMA-TEK (WRIGHT-GIEMSA) STAIN SOLUTIONmethanol Eyes - Moderate irritant Rabbit - 24 hours 100

    milligrams-

    Eyes - Moderate irritant Rabbit - 40 milligrams -Skin - Moderate irritant Rabbit - 24 hours 20

    milligrams-

    Poly(oxy-1,2-ethanediyl), α-[4-(1,1,3,3-tetramethylbutyl)phenyl]-ω-hydroxy-

    Eyes - Moderate irritant Rabbit - 24 hours 10 microliters

    -

    Skin - Mild irritant Rabbit - 24 hours 500 microliters

    -

    Product/ingredient name Result Score Exposure Observation

    Conclusion/Summary

    Skin : HEMA-TEK (WRIGHT-GIEMSA) BUFFER SOLUTION

    Not available.

    HEMA-TEK (WRIGHT-GIEMSA) RINSE SOLUTION

    Not available.

    HEMA-TEK (WRIGHT-GIEMSA) STAIN SOLUTION

    Not available.

    Eyes : HEMA-TEK (WRIGHT-GIEMSA) BUFFER SOLUTION

    Not available.

    HEMA-TEK (WRIGHT-GIEMSA) RINSE SOLUTION

    Not available.

    HEMA-TEK (WRIGHT-GIEMSA) STAIN SOLUTION

    Not available.

    Respiratory : HEMA-TEK (WRIGHT-GIEMSA) BUFFER SOLUTION

    Not available.

    HEMA-TEK (WRIGHT-GIEMSA) RINSE SOLUTION

    Not available.

    HEMA-TEK (WRIGHT-GIEMSA) STAIN SOLUTION

    Not available.

    Sensitization

    Not available.

    Conclusion/Summary

    Skin : HEMA-TEK (WRIGHT-GIEMSA) BUFFER SOLUTION

    Not available.

    HEMA-TEK (WRIGHT-GIEMSA) RINSE SOLUTION

    Not available.

    HEMA-TEK (WRIGHT-GIEMSA) STAIN SOLUTION

    Not available.

    Respiratory : HEMA-TEK (WRIGHT-GIEMSA) BUFFER SOLUTION

    Not available.

    HEMA-TEK (WRIGHT-GIEMSA) RINSE SOLUTION

    Not available.

    HEMA-TEK (WRIGHT-GIEMSA) STAIN SOLUTION

    Not available.

    Species

    Date of issue/Date of revision : 4/1/2020 Date of previous issue : 12/13/2018 Version : 1.08 12/23

  • HEMA-TEK (WRIGHT-GIEMSA) STAIN PAK

    Section 11. Toxicological information

    Carcinogenicity

    Not available.

    Conclusion/Summary : HEMA-TEK (WRIGHT-GIEMSA) BUFFER SOLUTION

    Not available.

    HEMA-TEK (WRIGHT-GIEMSA) RINSE SOLUTION

    Not available.

    HEMA-TEK (WRIGHT-GIEMSA) STAIN SOLUTION

    Not available.

    Conclusion/Summary : HEMA-TEK (WRIGHT-GIEMSA) BUFFER SOLUTION

    Not available.

    HEMA-TEK (WRIGHT-GIEMSA) RINSE SOLUTION

    Not available.

    HEMA-TEK (WRIGHT-GIEMSA) STAIN SOLUTION

    Not available.

    Teratogenicity

    Not available.

    Conclusion/Summary : HEMA-TEK (WRIGHT-GIEMSA) BUFFER SOLUTION

    Not available.

    HEMA-TEK (WRIGHT-GIEMSA) RINSE SOLUTION

    Not available.

    HEMA-TEK (WRIGHT-GIEMSA) STAIN SOLUTION

    Not available.

    Reproductive toxicity

    Conclusion/Summary : HEMA-TEK (WRIGHT-GIEMSA) BUFFER SOLUTION

    Not available.

    HEMA-TEK (WRIGHT-GIEMSA) RINSE SOLUTION

    Not available.

    HEMA-TEK (WRIGHT-GIEMSA) STAIN SOLUTION

    Not available.

    Not available.

    Specific target organ toxicity (single exposure)

    Specific target organ toxicity (repeated exposure)

    HEMA-TEK (WRIGHT-GIEMSA) RINSE SOLUTIONmethanol Category 1 Not determined Not determined

    HEMA-TEK (WRIGHT-GIEMSA) STAIN SOLUTIONmethanol Category 1 Not determined Not determined

    Name Category

    Not available.

    Aspiration hazard

    Not available.

    Route of exposure

    Target organs

    Classification

    HEMA-TEK (WRIGHT-GIEMSA) RINSE SOLUTIONmethanol None. - -

    HEMA-TEK (WRIGHT-GIEMSA) STAIN SOLUTIONmethanol None. - -

    Product/ingredient name NTPIARCOSHA

    Date of issue/Date of revision : 4/1/2020 Date of previous issue : 12/13/2018 Version : 1.08 13/23

  • HEMA-TEK (WRIGHT-GIEMSA) STAIN PAK

    Section 11. Toxicological informationInformation on the likely routes of exposure

    Inhalation : HEMA-TEK (WRIGHT-GIEMSA) BUFFER SOLUTION

    No known significant effects or critical hazards.

    HEMA-TEK (WRIGHT-GIEMSA) RINSE SOLUTION

    No known significant effects or critical hazards.

    HEMA-TEK (WRIGHT-GIEMSA) STAIN SOLUTION

    Toxic if inhaled.

    HEMA-TEK (WRIGHT-GIEMSA) BUFFER SOLUTION

    No known significant effects or critical hazards.

    HEMA-TEK (WRIGHT-GIEMSA) RINSE SOLUTION

    Harmful if swallowed.

    HEMA-TEK (WRIGHT-GIEMSA) STAIN SOLUTION

    Toxic if swallowed.

    :Ingestion

    Skin contact : HEMA-TEK (WRIGHT-GIEMSA) BUFFER SOLUTION

    No known significant effects or critical hazards.

    HEMA-TEK (WRIGHT-GIEMSA) RINSE SOLUTION

    May cause an allergic skin reaction.

    HEMA-TEK (WRIGHT-GIEMSA) STAIN SOLUTION

    Toxic in contact with skin.

    HEMA-TEK (WRIGHT-GIEMSA) BUFFER SOLUTION

    No known significant effects or critical hazards.

    HEMA-TEK (WRIGHT-GIEMSA) RINSE SOLUTION

    No known significant effects or critical hazards.

    HEMA-TEK (WRIGHT-GIEMSA) STAIN SOLUTION

    No known significant effects or critical hazards.

    :Eye contact

    Symptoms related to the physical, chemical and toxicological characteristics

    Skin contact

    Ingestion

    Inhalation HEMA-TEK (WRIGHT-GIEMSA) BUFFER SOLUTION

    No specific data.

    HEMA-TEK (WRIGHT-GIEMSA) RINSE SOLUTION

    No specific data.

    HEMA-TEK (WRIGHT-GIEMSA) STAIN SOLUTION

    No specific data.

    HEMA-TEK (WRIGHT-GIEMSA) BUFFER SOLUTION

    No specific data.

    HEMA-TEK (WRIGHT-GIEMSA) RINSE SOLUTION

    No specific data.

    HEMA-TEK (WRIGHT-GIEMSA) STAIN SOLUTION

    No specific data.

    HEMA-TEK (WRIGHT-GIEMSA) BUFFER SOLUTION

    No specific data.

    HEMA-TEK (WRIGHT-GIEMSA) RINSE SOLUTION

    Adverse symptoms may include the following:irritationredness

    HEMA-TEK (WRIGHT-GIEMSA) STAIN SOLUTION

    No specific data.

    :

    :

    :

    Eye contact : HEMA-TEK (WRIGHT-GIEMSA) BUFFER SOLUTION

    No specific data.

    HEMA-TEK (WRIGHT-GIEMSA) RINSE SOLUTION

    No specific data.

    HEMA-TEK (WRIGHT-GIEMSA) STAIN SOLUTION

    No specific data.

    Delayed and immediate effects and also chronic effects from short and long term exposure

    : HEMA-TEK (WRIGHT-GIEMSA) BUFFER SOLUTION

    Not available.

    HEMA-TEK (WRIGHT-GIEMSA) RINSE SOLUTION

    Not available.

    HEMA-TEK (WRIGHT-GIEMSA) STAIN SOLUTION

    Not available.

    Potential acute health effects

    Short term exposure

    Date of issue/Date of revision : 4/1/2020 Date of previous issue : 12/13/2018 Version : 1.08 14/23

  • HEMA-TEK (WRIGHT-GIEMSA) STAIN PAK

    Section 11. Toxicological information

    Not available.

    Conclusion/Summary : Not available. HEMA-TEK (WRIGHT-GIEMSA) BUFFER SOLUTION

    Not available. HEMA-TEK (WRIGHT-GIEMSA) RINSE SOLUTION

    Not available. HEMA-TEK (WRIGHT-GIEMSA) STAIN SOLUTION

    Once sensitized, a severe allergic reaction may occur when subsequently exposed to very low levels.

    General :

    No known significant effects or critical hazards.Carcinogenicity :

    No known significant effects or critical hazards.Mutagenicity :

    No known significant effects or critical hazards.Teratogenicity :

    Developmental effects : No known significant effects or critical hazards.

    Fertility effects : No known significant effects or critical hazards.

    Potential chronic health effects

    Numerical measures of toxicity

    HEMA-TEK (WRIGHT-GIEMSA) RINSE SOLUTIONOral 1274.7 mg/kgDermal 3824.1 mg/kgInhalation (vapors) 38.24 mg/l

    HEMA-TEK (WRIGHT-GIEMSA) STAIN SOLUTIONOral 102 mg/kgDermal 306.8 mg/kgInhalation (vapors) 3.068 mg/l

    Route ATE value

    Acute toxicity estimates

    Interactive effects : HEMA-TEK (WRIGHT-GIEMSA) BUFFER SOLUTION

    Not available.

    HEMA-TEK (WRIGHT-GIEMSA) RINSE SOLUTION

    Not available.

    HEMA-TEK (WRIGHT-GIEMSA) STAIN SOLUTION

    Not available.

    Potential immediate effects

    : HEMA-TEK (WRIGHT-GIEMSA) BUFFER SOLUTION

    Not available.

    HEMA-TEK (WRIGHT-GIEMSA) RINSE SOLUTION

    Not available.

    HEMA-TEK (WRIGHT-GIEMSA) STAIN SOLUTION

    Not available.

    Potential delayed effects : HEMA-TEK (WRIGHT-GIEMSA) BUFFER SOLUTION

    Not available.

    HEMA-TEK (WRIGHT-GIEMSA) RINSE SOLUTION

    Not available.

    HEMA-TEK (WRIGHT-GIEMSA) STAIN SOLUTION

    Not available.

    Potential immediate effects

    : HEMA-TEK (WRIGHT-GIEMSA) BUFFER SOLUTION

    Not available.

    HEMA-TEK (WRIGHT-GIEMSA) RINSE SOLUTION

    Not available.

    HEMA-TEK (WRIGHT-GIEMSA) STAIN SOLUTION

    Not available.

    Long term exposure

    Potential delayed effects : HEMA-TEK (WRIGHT-GIEMSA) BUFFER SOLUTION

    Not available.

    HEMA-TEK (WRIGHT-GIEMSA) RINSE SOLUTION

    Not available.

    HEMA-TEK (WRIGHT-GIEMSA) STAIN SOLUTION

    Not available.

    Date of issue/Date of revision : 4/1/2020 Date of previous issue : 12/13/2018 Version : 1.08 15/23

  • HEMA-TEK (WRIGHT-GIEMSA) STAIN PAK

    Section 11. Toxicological information

    Other information : HEMA-TEK (WRIGHT-GIEMSA) BUFFER SOLUTION

    Not available.

    HEMA-TEK (WRIGHT-GIEMSA) RINSE SOLUTION

    Not available.

    HEMA-TEK (WRIGHT-GIEMSA) STAIN SOLUTION

    Not available.

    Section 12. Ecological information

    Bioaccumulative potential

    Product/ingredient name Aquatic half-life Photolysis Biodegradability

    HEMA-TEK (WRIGHT-GIEMSA) RINSE SOLUTIONmethanol - - Readily

    HEMA-TEK (WRIGHT-GIEMSA) STAIN SOLUTIONmethanol - - Readily

    Toxicity

    HEMA-TEK (WRIGHT-GIEMSA) RINSE SOLUTIONmethanol Acute EC50 16.912 mg/l Marine water Algae - Ulva pertusa 96 hours

    Acute LC50 2500000 µg/l Marine water Crustaceans - Crangon crangon -Adult

    48 hours

    Acute LC50 3289 to 4395 mg/l Fresh water

    Daphnia - Daphnia magna -Neonate

    48 hours

    Acute LC50 290 mg/l Fresh water Fish - Danio rerio - Egg 96 hoursChronic NOEC 9.96 mg/l Marine water Algae - Ulva pertusa 96 hours

    HEMA-TEK (WRIGHT-GIEMSA) STAIN SOLUTIONmethanol Acute EC50 16.912 mg/l Marine water Algae - Ulva pertusa 96 hours

    Acute LC50 2500000 µg/l Marine water Crustaceans - Crangon crangon -Adult

    48 hours

    Acute LC50 3289 to 4395 mg/l Fresh water

    Daphnia - Daphnia magna -Neonate

    48 hours

    Acute LC50 290 mg/l Fresh water Fish - Danio rerio - Egg 96 hoursChronic NOEC 9.96 mg/l Marine water Algae - Ulva pertusa 96 hours

    Poly(oxy-1,2-ethanediyl), α-[4-(1,1,3,3-tetramethylbutyl)phenyl]-ω-hydroxy-

    Acute LC50 5.85 mg/l Fresh water Crustaceans - Ceriodaphnia rigaudi - Neonate

    48 hours

    Acute LC50 11.2 mg/l Fresh water Daphnia - Daphnia magna -Neonate

    48 hours

    Acute LC50 6000 µg/l Fresh water Fish - Pimephales promelas 96 hours

    Product/ingredient name SpeciesResult Exposure

    Conclusion/Summary : HEMA-TEK (WRIGHT-GIEMSA) BUFFER SOLUTION

    Not available.

    HEMA-TEK (WRIGHT-GIEMSA) RINSE SOLUTION

    Not available.

    HEMA-TEK (WRIGHT-GIEMSA) STAIN SOLUTION

    Not available.

    Persistence and degradability

    Conclusion/Summary : HEMA-TEK (WRIGHT-GIEMSA) BUFFER SOLUTION

    Not available.

    HEMA-TEK (WRIGHT-GIEMSA) RINSE SOLUTION

    Not available.

    HEMA-TEK (WRIGHT-GIEMSA) STAIN SOLUTION

    Not available.

    Date of issue/Date of revision : 4/1/2020 Date of previous issue : 12/13/2018 Version : 1.08 16/23

  • HEMA-TEK (WRIGHT-GIEMSA) STAIN PAK

    Section 12. Ecological information

    Mobility HEMA-TEK (WRIGHT-GIEMSA) BUFFER SOLUTION

    Not available.

    HEMA-TEK (WRIGHT-GIEMSA) RINSE SOLUTION

    Not available.

    HEMA-TEK (WRIGHT-GIEMSA) STAIN SOLUTION

    Not available.

    :

    LogPow BCF Potential

    Other adverse effects : No known significant effects or critical hazards.

    Product/ingredient name

    HEMA-TEK (WRIGHT-GIEMSA) RINSE SOLUTIONmethanol -0.77

  • HEMA-TEK (WRIGHT-GIEMSA) STAIN PAK

    Section 14. Transport informationHEMA-TEK (WRIGHT-GIEMSA) BUFFER SOLUTION

    -

    HEMA-TEK (WRIGHT-GIEMSA) RINSE SOLUTION

    -

    HEMA-TEK (WRIGHT-GIEMSA) STAIN SOLUTION

    Methanol

    HEMA-TEK (WRIGHT-GIEMSA) BUFFER SOLUTION

    -

    HEMA-TEK (WRIGHT-GIEMSA) RINSE SOLUTION

    -

    HEMA-TEK (WRIGHT-GIEMSA) STAIN SOLUTION

    3 (6.1)

    HEMA-TEK (WRIGHT-GIEMSA) BUFFER SOLUTION

    -

    HEMA-TEK (WRIGHT-GIEMSA) RINSE SOLUTION

    -

    HEMA-TEK (WRIGHT-GIEMSA) STAIN SOLUTION

    II

    HEMA-TEK (WRIGHT-GIEMSA) BUFFER SOLUTION

    -

    HEMA-TEK (WRIGHT-GIEMSA) RINSE SOLUTION

    -

    HEMA-TEK (WRIGHT-GIEMSA) STAIN SOLUTION

    -

    HEMA-TEK (WRIGHT-GIEMSA) BUFFER SOLUTION

    No.

    HEMA-TEK (WRIGHT-GIEMSA) RINSE SOLUTION

    No.

    HEMA-TEK (WRIGHT-GIEMSA) STAIN SOLUTION

    No.

    TDG Classification

    HEMA-TEK (WRIGHT-GIEMSA) BUFFER SOLUTION

    Not regulated.

    HEMA-TEK (WRIGHT-GIEMSA) RINSE SOLUTION

    Not regulated.

    HEMA-TEK (WRIGHT-GIEMSA) STAIN SOLUTION

    UN1230

    HEMA-TEK (WRIGHT-GIEMSA) BUFFER SOLUTION

    -

    HEMA-TEK (WRIGHT-GIEMSA) RINSE SOLUTION

    -

    HEMA-TEK (WRIGHT-GIEMSA) STAIN SOLUTION

    Methanol

    HEMA-TEK (WRIGHT-GIEMSA) BUFFER SOLUTION

    -

    HEMA-TEK (WRIGHT-GIEMSA) RINSE SOLUTION

    -

    HEMA-TEK (WRIGHT-GIEMSA) STAIN SOLUTION

    3 (6.1)

    HEMA-TEK (WRIGHT-GIEMSA) BUFFER SOLUTION

    -

    HEMA-TEK (WRIGHT-GIEMSA) RINSE SOLUTION

    -

    HEMA-TEK (WRIGHT-GIEMSA) STAIN SOLUTION

    II

    UN number

    UN proper shipping name

    Transport hazard class(es)

    Packing group

    UN proper shipping name

    Transport hazard class(es)

    Packing group

    Additional information

    Environmental hazards

    Date of issue/Date of revision : 4/1/2020 Date of previous issue : 12/13/2018 Version : 1.08 18/23

  • HEMA-TEK (WRIGHT-GIEMSA) STAIN PAK

    Section 14. Transport informationHEMA-TEK (WRIGHT-GIEMSA) BUFFER SOLUTION

    No.

    HEMA-TEK (WRIGHT-GIEMSA) RINSE SOLUTION

    No.

    HEMA-TEK (WRIGHT-GIEMSA) STAIN SOLUTION

    No.

    HEMA-TEK (WRIGHT-GIEMSA) BUFFER SOLUTION

    -

    HEMA-TEK (WRIGHT-GIEMSA) RINSE SOLUTION

    -

    HEMA-TEK (WRIGHT-GIEMSA) STAIN SOLUTION

    Product classified as per the following sections of the Transportation of Dangerous Goods Regulations: 2.18-2.19 (Class 3), 2.26-2.36 (Class 6).

    ADR/RID

    HEMA-TEK (WRIGHT-GIEMSA) BUFFER SOLUTION

    Not regulated.

    HEMA-TEK (WRIGHT-GIEMSA) RINSE SOLUTION

    Not regulated.

    HEMA-TEK (WRIGHT-GIEMSA) STAIN SOLUTION UN1230

    HEMA-TEK (WRIGHT-GIEMSA) BUFFER SOLUTION

    -

    HEMA-TEK (WRIGHT-GIEMSA) RINSE SOLUTION

    -

    HEMA-TEK (WRIGHT-GIEMSA) STAIN SOLUTION Methanol

    HEMA-TEK (WRIGHT-GIEMSA) BUFFER SOLUTION

    -

    HEMA-TEK (WRIGHT-GIEMSA) RINSE SOLUTION

    -

    HEMA-TEK (WRIGHT-GIEMSA) STAIN SOLUTION 3 (6.1)

    HEMA-TEK (WRIGHT-GIEMSA) BUFFER SOLUTION

    -

    HEMA-TEK (WRIGHT-GIEMSA) RINSE SOLUTION

    -

    HEMA-TEK (WRIGHT-GIEMSA) STAIN SOLUTION II

    HEMA-TEK (WRIGHT-GIEMSA) BUFFER SOLUTION

    No.

    HEMA-TEK (WRIGHT-GIEMSA) RINSE SOLUTION

    No.

    HEMA-TEK (WRIGHT-GIEMSA) STAIN SOLUTION No.

    HEMA-TEK (WRIGHT-GIEMSA) BUFFER SOLUTION

    -

    HEMA-TEK (WRIGHT-GIEMSA) RINSE SOLUTION

    -

    HEMA-TEK (WRIGHT-GIEMSA) STAIN SOLUTION -

    Additional information

    Environmental hazards

    UN number

    UN proper shipping name

    Transport hazard class(es)

    Packing group

    Additional information

    Environmental hazards

    HEMA-TEK (WRIGHT-GIEMSA) BUFFER SOLUTION

    Not regulated.

    HEMA-TEK (WRIGHT-GIEMSA) RINSE SOLUTION

    Not regulated.

    HEMA-TEK (WRIGHT-GIEMSA) STAIN SOLUTION UN1230

    IMDG

    UN number

    Date of issue/Date of revision : 4/1/2020 Date of previous issue : 12/13/2018 Version : 1.08 19/23

  • HEMA-TEK (WRIGHT-GIEMSA) STAIN PAK

    Section 14. Transport information

    HEMA-TEK (WRIGHT-GIEMSA) BUFFER SOLUTION

    -

    HEMA-TEK (WRIGHT-GIEMSA) RINSE SOLUTION

    -

    HEMA-TEK (WRIGHT-GIEMSA) STAIN SOLUTION

    Methanol

    HEMA-TEK (WRIGHT-GIEMSA) BUFFER SOLUTION

    Not regulated.

    HEMA-TEK (WRIGHT-GIEMSA) RINSE SOLUTION

    Not regulated.

    HEMA-TEK (WRIGHT-GIEMSA) STAIN SOLUTION

    UN1230

    HEMA-TEK (WRIGHT-GIEMSA) BUFFER SOLUTION

    -

    HEMA-TEK (WRIGHT-GIEMSA) RINSE SOLUTION

    -

    HEMA-TEK (WRIGHT-GIEMSA) STAIN SOLUTION

    3 (6.1)

    HEMA-TEK (WRIGHT-GIEMSA) BUFFER SOLUTION

    -

    HEMA-TEK (WRIGHT-GIEMSA) RINSE SOLUTION

    -

    HEMA-TEK (WRIGHT-GIEMSA) STAIN SOLUTION

    II

    IATA

    HEMA-TEK (WRIGHT-GIEMSA) BUFFER SOLUTION

    -

    HEMA-TEK (WRIGHT-GIEMSA) RINSE SOLUTION

    -

    HEMA-TEK (WRIGHT-GIEMSA) STAIN SOLUTION Methanol

    HEMA-TEK (WRIGHT-GIEMSA) BUFFER SOLUTION

    -

    HEMA-TEK (WRIGHT-GIEMSA) RINSE SOLUTION

    -

    HEMA-TEK (WRIGHT-GIEMSA) STAIN SOLUTION 3 (6.1)

    HEMA-TEK (WRIGHT-GIEMSA) BUFFER SOLUTION

    -

    HEMA-TEK (WRIGHT-GIEMSA) RINSE SOLUTION

    -

    HEMA-TEK (WRIGHT-GIEMSA) STAIN SOLUTION

    II

    HEMA-TEK (WRIGHT-GIEMSA) BUFFER SOLUTION

    -

    HEMA-TEK (WRIGHT-GIEMSA) RINSE SOLUTION

    -

    HEMA-TEK (WRIGHT-GIEMSA) STAIN SOLUTION -

    HEMA-TEK (WRIGHT-GIEMSA) BUFFER SOLUTION

    No.

    HEMA-TEK (WRIGHT-GIEMSA) RINSE SOLUTION

    No.

    HEMA-TEK (WRIGHT-GIEMSA) STAIN SOLUTION No.

    UN number

    UN proper shipping name

    Transport hazard class(es)

    Packing group

    UN proper shipping name

    Transport hazard class(es)

    Packing group

    Additional information

    Environmental hazards

    Date of issue/Date of revision : 4/1/2020 Date of previous issue : 12/13/2018 Version : 1.08 20/23

  • HEMA-TEK (WRIGHT-GIEMSA) STAIN PAK

    Section 14. Transport information

    HEMA-TEK (WRIGHT-GIEMSA) BUFFER SOLUTION

    -

    HEMA-TEK (WRIGHT-GIEMSA) RINSE SOLUTION

    -

    HEMA-TEK (WRIGHT-GIEMSA) STAIN SOLUTION

    -

    HEMA-TEK (WRIGHT-GIEMSA) BUFFER SOLUTION

    No.

    HEMA-TEK (WRIGHT-GIEMSA) RINSE SOLUTION

    No.

    HEMA-TEK (WRIGHT-GIEMSA) STAIN SOLUTION

    No.

    Special precautions for user

    Transport in bulk according to Annex II of MARPOL and the IBC Code

    HEMA-TEK (WRIGHT-GIEMSA) BUFFER SOLUTION

    Transport within user’s premises:always transport in closed containers that are upright and secure. Ensure that persons transporting the product know what to do in the event of an accident or spillage.

    HEMA-TEK (WRIGHT-GIEMSA) RINSE SOLUTION

    Transport within user’s premises:always transport in closed containers that are upright and secure. Ensure that persons transporting the product know what to do in the event of an accident or spillage.

    HEMA-TEK (WRIGHT-GIEMSA) STAIN SOLUTION

    Transport within user’s premises:always transport in closed containers that are upright and secure. Ensure that persons transporting the product know what to do in the event of an accident or spillage.

    :

    Additional information

    Environmental hazards

    Not applicable.

    Section 15. Regulatory informationU.S. Federal regulations TSCA 4(a) proposed test rules: Quaternary ammonium compounds, benzyl-

    C12-16-alkyldimethyl, chlorides

    Clean Water Act (CWA) 311: disodium hydrogenorthophosphate

    :

    Clean Air Act Section 112(b) Hazardous Air Pollutants (HAPs)

    : Listed

    Clean Air Act Section 602 Class I Substances

    : Not listed

    Clean Air Act Section 602 Class II Substances

    : Not listed

    DEA List I Chemicals (Precursor Chemicals)

    : Not listed

    DEA List II Chemicals (Essential Chemicals)

    : Not listed

    TSCA 8(a) PAIR: 1,1'-oxydipropan-2-ol; Poly(oxy-1,2-ethanediyl), α-[4-(1,1,3,3-tetramethylbutyl)phenyl]-ω-hydroxy-

    TSCA 8(a) CDR Exempt/Partial exemption: Not determined

    Commerce control list precursor: dimethylammonium chloride

    United States inventory (TSCA 8b): Not determined.

    SARA 302/304

    Date of issue/Date of revision : 4/1/2020 Date of previous issue : 12/13/2018 Version : 1.08 21/23

  • HEMA-TEK (WRIGHT-GIEMSA) STAIN PAK

    Section 15. Regulatory information

    The following components are listed: METHANOL

    WARNING: This product contains a chemical known to the State of California to cause birth defects or other reproductive harm.

    Massachusetts :

    SARA 313

    Product name CAS number %

    SARA 313 notifications must not be detached from the SDS and any copying and redistribution of the SDS shall include copying and redistribution of the notice attached to copies of the SDS subsequently redistributed.

    HEMA-TEK (WRIGHT-GIEMSA) RINSE SOLUTIONmethanol 67-56-1 7.845

    HEMA-TEK (WRIGHT-GIEMSA) STAIN SOLUTIONmethanol 67-56-1 97.792

    HEMA-TEK (WRIGHT-GIEMSA) RINSE SOLUTIONmethanol 67-56-1 7.845

    HEMA-TEK (WRIGHT-GIEMSA) STAIN SOLUTIONmethanol 67-56-1 97.792

    Form R - Reporting requirements

    Supplier notification

    California Prop. 65

    New York : The following components are listed: Methanol

    New Jersey : The following components are listed: METHYL ALCOHOL; METHANOL

    Pennsylvania : The following components are listed: METHANOL

    State regulations

    SARA 304 RQ : Not applicable.

    No products were found.

    Composition/information on ingredients

    SARA 311/312

    Classification : Immediate (acute) health hazard

    HEMA-TEK (WRIGHT-GIEMSA)RINSE SOLUTIONmethanol 7.845 Yes. No. No. Yes. No.reaction mass of: 5-chloro-2-methyl-4-isothiazolin-3-one [EC no.247-500-7] and 2-methyl-2H-isothiazol-3-one [EC no. 220-239-6] (3:1)

    0.003708 No. No. No. Yes. No.

    HEMA-TEK (WRIGHT-GIEMSA)STAIN SOLUTIONmethanol 97.792 Yes. No. No. Yes. No.Poly(oxy-1,2-ethanediyl), α-[4-(1,1,3,3-tetramethylbutyl)phenyl]-ω-hydroxy-

    1.339 No. No. No. Yes. No.

    Name % Fire hazard

    Sudden release of pressure

    Reactive Immediate (acute)health hazard

    Delayed (chronic)health hazard

    Composition/information on ingredients

    Date of issue/Date of revision : 4/1/2020 Date of previous issue : 12/13/2018 Version : 1.08 22/23

  • HEMA-TEK (WRIGHT-GIEMSA) STAIN PAK

    Section 15. Regulatory information

    HEMA-TEK (WRIGHT-GIEMSA)RINSE SOLUTIONMethanol No. Yes. No. 23000 µg/day

    (ingestion)47000 µg/day (inhalation)

    HEMA-TEK (WRIGHT-GIEMSA)STAIN SOLUTIONMethanol No. Yes. No. 23000 µg/day

    (ingestion)47000 µg/day (inhalation)

    Ingredient name Cancer Reproductive No significant risk level

    Maximum acceptable dosage level

    International regulations

    Chemical Weapons Convention List Schedule I Chemicals

    : HEMA-TEK (WRIGHT-GIEMSA) BUFFER SOLUTION

    Not listed

    HEMA-TEK (WRIGHT-GIEMSA) RINSE SOLUTION

    Not listed

    HEMA-TEK (WRIGHT-GIEMSA) STAIN SOLUTION

    Not listed

    Chemical Weapons Convention List Schedule II Chemicals

    : HEMA-TEK (WRIGHT-GIEMSA) BUFFER SOLUTION

    Not listed

    HEMA-TEK (WRIGHT-GIEMSA) RINSE SOLUTION

    Not listed

    HEMA-TEK (WRIGHT-GIEMSA) STAIN SOLUTION

    Not listed

    Chemical Weapons Convention List Schedule III Chemicals

    : HEMA-TEK (WRIGHT-GIEMSA) BUFFER SOLUTION

    Not listed

    HEMA-TEK (WRIGHT-GIEMSA) RINSE SOLUTION

    Not listed

    HEMA-TEK (WRIGHT-GIEMSA) STAIN SOLUTION

    Not listed

    Section 16. Other informationHistory

    Date of issue/Date of revision

    Version :

    :

    Indicates information that has changed from previously issued version.

    Key to abbreviations : ATE = Acute Toxicity EstimateBCF = Bioconcentration FactorGHS = Globally Harmonized System of Classification and Labelling of ChemicalsIATA = International Air Transport AssociationIBC = Intermediate Bulk ContainerIMDG = International Maritime Dangerous GoodsLogPow = logarithm of the octanol/water partition coefficientMARPOL = International Convention for the Prevention of Pollution From Ships, 1973 as modified by the Protocol of 1978. ("Marpol" = marine pollution)UN = United Nations

    4/1/2020

    1.08

    Date of issue/Date of revision : 4/1/2020 Date of previous issue : 12/13/2018 Version : 1.08 23/23