Safety and Standard Protection Code Questions 1. One who is instructed or delegated to perform specified operation at an unattended station is known as ____________. a. Operator b. Local Manager c. Agent d. Qualified Staff 2. DO NOT OPERATE tag (DNO) for station guarantee is ______________ in color. a. Black b. Yellow c. Green d. White 3. Which of the following DOES NOT fall under formal protection guarantee? a. Work Permit b. Work and Test Permit c. Station Guarantee d. Self Protection 4. Safety Rule 200 Series is for ___________________________________. a. General rules for all employees engaged in construction, operation and maintenance b. Apparatus to be treated as alive c. Authority for work d. Orders and Messages 5. The minimum distance that an unqualified personnel should keep between himself and live 33kV apparatus is ______ a. 1m b. 0.85m c. 1.2m d. 3m 6. The insulation of conductors operating at voltage levels in excess of 750V phase to phase should not be depended upon for protection unless: a. Enclosed in a grounded metal sheath b. Enclosed in a shielded conductor with the shield grounded c. Specially insulated for a specific application such as ‘Air Break Switch’ d. All of the above 7. Safety Rule _____________ states - “All workers except the crane operator shall keep clear of the ladder and crane while it is in motion”. a. 200: Apparatus to be treated as alive b. 201: Authority for work

Safety and Standard Protection Code Questions

Embed Size (px)

DESCRIPTION

QUESTIONS

Citation preview

Page 1: Safety and Standard Protection Code Questions

Safety and Standard Protection Code Questions1. One who is instructed or delegated to perform specified operation at an unattended station is

known as ____________.a. Operatorb. Local Managerc. Agent d. Qualified Staff

2. DO NOT OPERATE tag (DNO) for station guarantee is ______________ in color.a. Blackb. Yellowc. Greend. White

3. Which of the following DOES NOT fall under formal protection guarantee?a. Work Permitb. Work and Test Permitc. Station Guaranteed. Self Protection

4. Safety Rule 200 Series is for ___________________________________.a. General rules for all employees engaged in construction, operation and maintenance b. Apparatus to be treated as alivec. Authority for workd. Orders and Messages

5. The minimum distance that an unqualified personnel should keep between himself and live 33kV apparatus is ______

a. 1mb. 0.85mc. 1.2m d. 3m

6. The insulation of conductors operating at voltage levels in excess of 750V phase to phase should not be depended upon for protection unless:

a. Enclosed in a grounded metal sheathb. Enclosed in a shielded conductor with the shield groundedc. Specially insulated for a specific application such as ‘Air Break Switch’d. All of the above

7. Safety Rule _____________ states - “All workers except the crane operator shall keep clear of the ladder and crane while it is in motion”.

a. 200: Apparatus to be treated as aliveb. 201: Authority for workc. 202: Order and messagesd. 204: Un-insulated boom type equipment

8. The standard protection code for ‘Order to Operate’ form is ________.a. O.F. 100b. O.F. 10c. O.F. 17 d. O.F. 19

9. Types of protection must be established based on the following, except________.a. The apparatusb. Voltages involvedc. Work Permit d. Nature of work

Page 2: Safety and Standard Protection Code Questions

10. ___________ is a the tag for operational warningsa. Hold off tagb. Work Permitc. Work and Test permitd. Caution Tag

11. Standard Protection Code can be separated into three sections namely:a. Hold off, Self Protection & Station Guaranteeb. Hold off, Caution & Protection Guaranteec. Hold off, Self Protection & Protection Guarantee d. Hold off, Self Protection & Work permit

12. All of the following must be submitted by the applicant when applying for protection guarantee, except

a. Applicant’s identityb. Name and contact information of customer affected by faulty equipment c. Time and date schedule for work to begin and endd. The equipment/apparatus to be worked on

13. The guarantee which carried with it the assurance that specified isolating or de-energizing devices are in a specified guaranteed position and that they will remain in that position until the holder surrenders it is:

a. Protection guaranteeb. Caution guaranteec. Station guarantee d. Work and test guarantee

14. Hold off tag is used to _____________a. Start substation maintenance workb. Stop substation maintenance workc. De-energize electrical apparatusd. Prevent re-energizing of electrical apparatus till confirmation is received from

workmen15. Protection guarantee includes:

a. Work permitsb. Work and test permitsc. Station guaranteed. All of the above

16. ‘Hold Off’ tag code is______________a. O.F. 16b. O.F. 1c. O.F. 12 d. O.F. 56

17. From the electrical safety point of view, an ‘agent’ is generally regarded as:a. An unqualified operator b. A qualified operatorc. A distribution station operatord. A senior electrical operator

18. In the standard protection code, the term ‘QUALIFIED’ refers to:a. The holder of the protection guarantee certificateb. Personnel with prescribed standards of procedure and conductc. Personnel with experience, education, physical fitness and familiarity with rules,

procedure, apparatus and dangers involved in work and operationd. All personnel described in the Standard protection code

Page 3: Safety and Standard Protection Code Questions

19. A form of protection guarantee issued by a master station to a qualified person, under which specific work is authorized on specified apparatus is known as:

a. O.F. 1b. O.F. 2 c. O.F. 3d. O.F. 4

20. The name of the protection guarantee in ‘Question 19’ above isa. Self Protectionb. Cautionc. Work Permit d. Application for protection guarantee