 SA#: 05-037 REVISION: Release REVISION DATE: N/A ISSUE DATE: 6/3/05 AUTHOR:  M. Zink Customer Engineering  Electro-Motive Diesel, Inc.  9301 W. 55th Street  LaGrange, IL 60525 SERVICE ADVISORY - Undesired Emergency and Penalty Brake Applications due to Blanking ICE Screen Form CEF-001 Rev A. 4/5//05 Page 1 Copyright  Electro-Motive Diesel, In c.. All rights reserved. Neither this document, nor any par t thereof, may be reproduced or reprinted without the prior written consent of the Electro-Motive Diesel, Inc. . Contact EMD SDO office. Locomotive(s) Affected: Union Pacific 8000 – 8308 Union Pacific 8500 – 8521 Purpose: The purpose of this Service Advisory is to direct Field personnel in gathering information that will further an investigation into why units go int o an undesired penalty or emergency brake applications. This  problem has also been reported in conjunction with the Integrated Cab Electronics (ICE) Consolidated Cab Computer (CCC) shutting down for four (4) to six (6) minutes and may also be linked to the ICE screens going blank. Action Required: In the event of an ICE equipped locomotive having undesired penalty and emergency air brake applications and is also reported as having its screens going blank, please perform the following actions while the unit is running. A worksheet has been provided on the next page for your convenience, please fax this to Mike Zink at (708) 387-5795. 1. Check to see if the Rockwell Train Power Supply (TPS) circuit breaker (located on the front of the TPS) has tripped, shown in Figure 1. 2. Check the connections on the TPS to ensure a good connection. 3. Ensure that the TPS is secured in its location and tight in the Train Equipment Unit (TEU) cabinet. 4. Measure and record the ICE Blower current with a clamp-on amp meter. This can best be accomplished by measuring the wire tagged “BLMP” connected on TB3 #3 terminal, shown in Figure 1, inside the Rockwell TEU cabinet. 5. If ICE Blower filters are dirty, remove and return the filter elements (EMD #: 40041374) in a  plastic bag so that any captured debris is not lost to Mike Zink in LaGrange. This filter is located on the backside of the Engineer’s console in the vestibule area, as shown in Figure 2. 6. With t he ICE blower filt er removed, inspect the ICE Blower for correct blower wheel rotation. The  blower wheel should rotate clockwise, as shown in Figure 3. 7. Inspect the ICE Blower ducting to ensure that there are no restrictions. The ducting runs along the  bottom and left hand side of the TEU. 8. Move the TPS from its location and feel for cooling air coming from the air manifold, shown in Figure 4. 9. Download the event recorder and EM2000 archives. Send the event recorder download to Mike Zink at [email protected]. 10. Contact the local Wabtec representative for download of the Consolidated Cab Computer (CCC). Send this archive to [email protected] as well. 11. If no other defects are found, replace the TPS (EMD New #: 40068673, UTEX 40103589) and ICE Blower assembly (EMD New #: 40041319, UTEX 40064469) and call Bob Farar at (402)544-2397.

SA-05-037 Undesired Emergency and Penalty Brake Applications Due to Blanking ICE Screen

Embed Size (px)

Citation preview

8/10/2019 SA-05-037 Undesired Emergency and Penalty Brake Applications Due to Blanking ICE Screen

http://slidepdf.com/reader/full/sa-05-037-undesired-emergency-and-penalty-brake-applications-due-to-blanking 1/4

 

SA#: 05-037

REVISION: Release

REVISION DATE: N/A 

ISSUE DATE: 6/3/05

AUTHOR:  M. Zink

Customer Engineering •  Electro-Motive Diesel, Inc. •  9301 W. 55th Street •  LaGrange, IL 60525 

SERVICE ADVISORY -

Undesired Emergency and Penalty Brake Applications due to

Blanking ICE ScreenForm CEF-001 Rev A. 4/5//0

Page 1 

Copyright  Electro-Motive Diesel, Inc.. All rights reserved. Neither this document, nor any part thereof, may be reproduced or reprinted without the prior written

consent of the Electro-Motive Diesel, Inc.. Contact EMD SDO office.

Locomotive(s) Affected:

Union Pacific 8000 – 8308

Union Pacific 8500 – 8521

Purpose:

The purpose of this Service Advisory is to direct Field personnel in gathering information that will further

an investigation into why units go into an undesired penalty or emergency brake applications. This

 problem has also been reported in conjunction with the Integrated Cab Electronics (ICE) Consolidated Cab

Computer (CCC) shutting down for four (4) to six (6) minutes and may also be linked to the ICE screens

going blank.

Action Required:

In the event of an ICE equipped locomotive having undesired penalty and emergency air brake applications

and is also reported as having its screens going blank, please perform the following actions while the unit

is running. A worksheet has been provided on the next page for your convenience, please fax this to Mike

Zink at (708) 387-5795.

1. Check to see if the Rockwell Train Power Supply (TPS) circuit breaker (located on the front of the

TPS) has tripped, shown in Figure 1.

2. Check the connections on the TPS to ensure a good connection.

3. Ensure that the TPS is secured in its location and tight in the Train Equipment Unit (TEU) cabinet.

4. Measure and record the ICE Blower current with a clamp-on amp meter. This can best be

accomplished by measuring the wire tagged “BLMP” connected on TB3 #3 terminal, shown in

Figure 1, inside the Rockwell TEU cabinet.

5. If ICE Blower filters are dirty, remove and return the filter elements (EMD #: 40041374) in a

 plastic bag so that any captured debris is not lost to Mike Zink in LaGrange. This filter is located

on the backside of the Engineer’s console in the vestibule area, as shown in Figure 2.

6. With the ICE blower filter removed, inspect the ICE Blower for correct blower wheel rotation. The

 blower wheel should rotate clockwise, as shown in Figure 3.

7. Inspect the ICE Blower ducting to ensure that there are no restrictions. The ducting runs along the

 bottom and left hand side of the TEU.

8. Move the TPS from its location and feel for cooling air coming from the air manifold, shown in

Figure 4.

9. Download the event recorder and EM2000 archives. Send the event recorder download to Mike

Zink at [email protected].

10. Contact the local Wabtec representative for download of the Consolidated Cab Computer (CCC).

Send this archive to [email protected] as well.

11. If no other defects are found, replace the TPS (EMD New #: 40068673, UTEX 40103589) and ICE

Blower assembly (EMD New #: 40041319, UTEX 40064469) and call Bob Farar at (402)544-2397.

8/10/2019 SA-05-037 Undesired Emergency and Penalty Brake Applications Due to Blanking ICE Screen

http://slidepdf.com/reader/full/sa-05-037-undesired-emergency-and-penalty-brake-applications-due-to-blanking 2/4

 

SA#: 05-037

REVISION: Release

REVISION DATE: N/A 

ISSUE DATE: 6/3/05

AUTHOR:  M. Zink

Customer Engineering •  Electro-Motive Diesel, Inc. •  9301 W. 55th Street •  LaGrange, IL 60525 

SERVICE ADVISORY -

Undesired Emergency and Penalty Brake Applications due to

Blanking ICE ScreenForm CEF-001 Rev A. 4/5//0

Page 2 

Copyright  Electro-Motive Diesel, Inc.. All rights reserved. Neither this document, nor any part thereof, may be reproduced or reprinted without the prior written

consent of the Electro-Motive Diesel, Inc.. Contact EMD SDO office.

Background:

There have been several reports from the Union Pacific of instances where units have gone into either

 penalty brake applications (if lead unit in conventional mode or distributed power lead consist) or

emergency brake applications (if in lead unit of distributed power remote consist). Event recorder

downloads of these events show that the event recorder had lost power and then later shows the CCC

 powering back up. For these reasons and the reported screen blanking mentioned earlier, the investigation

has focused on the TPS and environmental factors that may affect its performance.

Figure 1: TPS and TB3 in TEU

Figure 2: ICE Blower Filter Location 

Figure 3: ICE Blower Squirrel Cage  Figure 4: TPS Air Manifold Outlet 

TPS

Circuit

Breaker

Terminal

Board #3

Rotation

Air Flow

8/10/2019 SA-05-037 Undesired Emergency and Penalty Brake Applications Due to Blanking ICE Screen

http://slidepdf.com/reader/full/sa-05-037-undesired-emergency-and-penalty-brake-applications-due-to-blanking 3/4

 

SA#: 05-037

REVISION: Release

REVISION DATE: N/A 

ISSUE DATE: 6/3/05

AUTHOR:  M. Zink

Customer Engineering •  Electro-Motive Diesel, Inc. •  9301 W. 55th Street •  LaGrange, IL 60525 

SERVICE ADVISORY -

Undesired Emergency and Penalty Brake Applications due to

Blanking ICE ScreenForm CEF-001 Rev A. 4/5//0

Page 3 

Copyright  Electro-Motive Diesel, Inc.. All rights reserved. Neither this document, nor any part thereof, may be reproduced or reprinted without the prior written

consent of the Electro-Motive Diesel, Inc.. Contact EMD SDO office.

Unit: _______________ Inspected By: ________________________________ 

Location: __________________________________ Date: ____________  

Initials Item

Did the TPS circuit breaker trip? Yes No

TPS connections good? Yes No

TPS secured in correct location? Yes No

Measured ICE Blower current. Amps

ICE Blower filters removed? (EMD #: 40041374) Yes No

ICE Blower has correct rotation? Blower rotates clockwise. Yes No

 Any ICE Blower duct restrictions? Yes No

Good air flow from TPS air manifold? Yes No

Event recorder downloads sent? Yes No

EM2000 downloads sent? Yes No

CCC download sent? Yes No

TPS replaced? (EMD New #: 40068673, UTEX 40103589) Yes No

ICE Blower replaced? (EMD New #: 40041319, UTEX 40064469) Yes No

Comments:

Please fax sheet to Mike Zink at (708)387-5795

(Please circle)

Train Power Supply (TPS) and Intergrated

Cab Electronics (ICE) Inspection Sheet

 

8/10/2019 SA-05-037 Undesired Emergency and Penalty Brake Applications Due to Blanking ICE Screen

http://slidepdf.com/reader/full/sa-05-037-undesired-emergency-and-penalty-brake-applications-due-to-blanking 4/4

 

SA#: 05-037

REVISION: Release

REVISION DATE: N/A 

ISSUE DATE: 6/3/05

AUTHOR:  M. Zink

Customer Engineering •  Electro-Motive Diesel, Inc. •  9301 W. 55th Street •  LaGrange, IL 60525 

SERVICE ADVISORY -

Undesired Emergency and Penalty Brake Applications due to

Blanking ICE ScreenForm CEF-001 Rev A. 4/5//0

Page 4 

Copyright  Electro-Motive Diesel, Inc.. All rights reserved. Neither this document, nor any part thereof, may be reproduced or reprinted without the prior written

consent of the Electro-Motive Diesel, Inc.. Contact EMD SDO office.

(For EMD Office Use Only)

Approvals (Required):

Approval

Needed

Y N

Approver Approved

Y N N/A

Approved By Date

CES/CEM Chris Harkness 6/3/05Warranty

Marketing

Service Advisory – General Classification (Select All that Apply):

GENERAL INFORMATION: This document is being issued to provide general information to the Customer Care Field Organization.

REQUEST FOR FIELD SUPPORT: This document is being issued to request Customer Care Field resources for the purpose of information/data

collection in support of a current field issue investigation.

PRELIMINARY: This document is being issued to provide notable preliminary findings with regard to a current field issue. It will be followed by the

issuance of an appropriate revision, or revisions, as the investigation progresses through closure, or more information becomes available.

FINAL: This document is being issued to provide final findings and recommendations on the proper handling of a current field issue. This document is

intended to provide official closure of the subject field issue.