Contents
I. Instrument List for Domestic
1. Building Materials(Construction Products) 2. Wire & Electric Cables3. Transportation(Railway) 4. UN Hazard Test 5. Petroleum Products6. New Renewable Energy(IEC 61730-1&2) 7. Fire Protection
II. Instrument List for International
1. Industrial Section 1.1 European CPD(Construction Products Directive) 1.2 European Railway1.3 European Roofing Products 1.4 US Transportation 1.5 Plastics1.6 Aviation
2. FTP Code, Fire Test Procedure3. IEC Standards : International Electro-technical Commission4. UL : Underwriter’s Laboratories
III. Instrument List by Parameter
1. Oxygen Consumption Calorimeter 2. Heat Release Rate 3. Smoke Production4. Ignitability 5. Flame Spread 6. Toxicity / Corrosivity 7. Mass Loss8. Fire Resistance
IV. Test Parameters
FIRE ENGINEERING & SCIENCE TECHNOLOGY
I. Instrument List for Domestic (Korea)
I. Instrument List for Domestic (Korea)
1. Building Materials (Construction Products)
No. Test Specifications(Test Regulation) Picture Name Starndard Test Overview Evaluation Criteria
1
Retardant Standardfor
building aninterior/finishingmaterials
* MLTM(Ministry ofLand,
Transport and Maritime
Affairs) notices article2006�476
Mouse Tester,Noxious Gas Tester
by MouseMT-503, MT-P03
KS F 2271
Measures experimentalwhite rat’s action for acertain time by test sam-ple from noxious gas(HCN, HCL) test by heat-ing test sample when ex-perimental white rats areexposed to test sample.
Classes: Non�Combustible/Semi noncom-bustible/Incombustible materials*KS F ISO 1182 (Non�combustible Test)� The highest temperature in furnace afterstarting to heat for 20 minutes will not ex-cess more than average temperature 20k
� the mass reduction rate of specimen atthe end of the heating test shall be lessthan 30%*KS F 2271 (Noxious Gas Test Method)� the average action stops hour of labora-tory rats shall be more than 9 minutes*KS F ISO 5660 (Cone Calorimeter TestMethod)
� Mass Heat Release Rate shall not exceed8MJ/㎡ for 10 minutes after heating
� after heating the specimen, 10 minutes(Seminoncombustible), 5 minutes(Incombustible),the specimen should not be shown"cracks", "holes", and "melt"(in case ofconfound materials, include melting thewhole reality and destroyed)*Attachment 1. see Flame retardant Stan-dard table for building internal finishingmaterials
Non-CombustibilityTester
NC-502, NC-P02
ISO 1182,KS F ISO1182
JIS A 1321,KS F 2271
Non�Combustibility Testermeasures incombustibilityand combustibility of uni-form building material andnonuniform building ma-terial of actual element.
Cone CalorimeterCC-105, CC-P05
ISO 5660,ASTM E1354,
NFPA 264,BS 476 pt15
Cone Calorimeter meas-ures heat release rate,smoke release, ignitiontime, oxygen consump-tion, carbon monoxideand carbon dioxide gen-eration and mass loss ratehen test sample is eposed to resource of con-ical heater.
Instrument List by Class
No. Test Specifications(Test Regulation) Picture Name Starndard Test Overview Evaluation Criteria
2
Building regulations forInterior decorativematerials
(Fire Service Law. Ar-ticle 20)
Smoke Box,Smoke DensityChamber
SB-501, SB-P01
ASTM E 662,BSI 6401,ISO 5659-2,NES 711,NFPA 258
Smoke Box measures opticaldensity of smoke generatedfrom test sample when testsample of certain thickness isexposed to heat source or firein a chamber.
*Building requlations for Inte-rior decorative materials
� Fire Fighting Regulation Arti-cle 20.(Standard for retardantitems and performance) Sec-tion 5 : maximum smoke realeasrate is up to below 400.
3
A fire�resistance testmethod for a fire
door(F�2268)
Vertical FurnaceCritical Heat Flux
Tester,V.F Heat Flux TesterVFH-V25, VFH-H25
KS F 2268,FTP Code 1
It is a heat (radiant heat) fluxtester of limited window orfire�retardant door to preventspread of fire and to secureexit path near the window orfire�retardant door.
*FTP Code I/ Annex 1/3/ Ap-pendix 1. A grade, B gradeand F class : heat emissiontest for window
4
ISO 834:Fire Resistance
Tests�Elements of build-
ingconstruction
Building Construc-tion Fire Resistance
TesterISO 834, BS 476�20,
21, 22, 23,BS EN 1363�1, 2, BS
EN 1364�1,2, BS EN 1366�1, 2,3, KS F 2275�
1, KS F 2268�1, KS F2846, KS B6951
ISO 834-1, ISO834-4~9,KS F 2275-1,KS F 2268-1
BS 476, BS EN1363, BS EN 1364, BS EN1365, BS EN 1366, BSEN 1634-1, ASTM E119, ASTM E 814, UL10, UL 263, UL 1709,UL 1479, ISO 3008,
ISO 3009
It measures the performanceof construction material againststandard fire conditions, andsatisfies the general require-ments, vertical history sectionmaterial, vertical non�historysection material and thefire�proof door’s fire proof test-ing.
-After applying a certain amount ofhead within the fireproof door (ISOCurve) and measure the degree oftwist (disposition) and any dam-ages due to heat, and additionallymeasure any flow of heat towardsthe exterior.-Measure the pressure (Pa) in Fur-nace during test and print asGraph.-Measure temperature (℃) in Fur-nace during test and print asGraph.-Available to record for character-istic and damage on specimenduring the test.
2
3/FIRE ENGINEERING & SCIENCE TECHNOLOGY
I. Instrument List for Domestic (Korea)Instrument List by Class
No. Criteria TestingType Picture Name Starndard Test Overview Evaluation Criteria
1
KEPCOStan-dardforCablePur-chase(KS IEC60502�1&2)
CableType(HFCO)
Bunched Cable Ver-tical Flame Spread
TesterVFT-716
KS C IEC60332-3-24
It measures to test for flame spread, propaga-tion characteristics for a single vertical insu-lated wire or cable and define of verticalarrangement fire spread by electric or opticalwhen cable is arrange vertically.(If added as option, Heat Release Rate (HRR)and Smoke Production Rate (SPR) could bemeasured)
*KEPCO_Standard for cablePurchasing (KS IEC 60502�1):Do not combustion more than2.5m of distance from burner.
3 Meter Cube SmokeDensity Tester
CSD-S14, CSD-W14IEC 61034
Measuring the smoke generated when the cable oroptical cable is placed horizontally and burn underdefinite fire resource in the specified condition (3㎥chamber required by IEC 61034).
*KEPCO_Standard for CablePurchasing (KS IEC 60502�2):More than 60% of light tran-sitivity
Test on Gas Evolvedduring combustion ofelectric cables tester,Cable Halogen, PH &Conductivity Tester
HCT-717
IEC 60754-1&2, KS CIEC
60754-1&2
Measures gas volume of Halogen Acid(IEC 60754�1), pH concentration(PHMeter, Hydrogen ions, IEC 60754�2),Conductivity(IEC 60754�2) and etc froma wire (cable) by radiant heat in theTube Furnace (IEC 60754�1: 800°c, IEC60754�2: 950°c)
*KEPCO_ Standard for cable pur-chasing (KS IEC 60502�1): (Hydro-gen chloride gas production rate)less than 0.5% of HCI gas produc-tion/ (Hydrogen Ion concentrationand conductivity) more tha PH 4.3,and less than Conductivity 10μs/mm
Fire Resistance TesterCFR-818, CFR-P18
IEC 60331-11&21
FESTEC’s IEC 60331�11 tester is usedin test conditions where the basicflame temperature is at least 750℃and tests the cable exposed to theflame that needs to maintain the circuitintegrity.
*KEPCO-Standard for cablepurchasing (KS IEC 60502�2):Endure for 15min in Test volt-age 21kV (KS C 3341, Graph 1)*Minimum maintenance time� IEC 60331�11: 90 min. (After re-moval flame +15min.)
Fire Mechanical ShockTester
CFM-819, CFM-P19
IEC 60331-12&31
This tester is used in test conditions wherethe basic flame temperature is at least 830℃and tests the cable exposed to flame andmechanical shock that needs to maintain thecircuit integrity.
*KEPCO_Standard for cable pur-chasing (KS IEC 60502�2): Endure10 times in ±75kV*Minimum maintenance time- IEC 60331�12: 120 min
2. Wire & Electric Cables
4
5/FIRE ENGINEERING & SCIENCE TECHNOLOGY
No. Criteria TestingType Picture Name Starndard Test Overview Evaluation Criteria
1
KEPCOStan-dardforCablePur-chase(KS IEC60502�1&2)
CableType(FR�CNCO�W)
Smoke Box,Smoke DensityChamber
SB-501, SB-P01
ASTM E 662,BSI 6401,ISO 5659,NES 711,NFPA 258
Smoke Box measures optical density ofsmoke generated from test samplewhen test sample of certain thicknessis exposed to heat source or fire in achamber.
*KEPCO Standard criteria(ES�6145�0019, Graph.7)*Lower than 150 of Dm (Den-sity max, Smoke Densitymaximum value)
Oxygen Index TesterLimited Oxygen Index
TesterLOI-404, LOI-P04
ASTM D2863,
ISO 4589-2,NES 714
LOI(Limited Oxygen Index tester) meas-ures minimum oxygen concentration asnecessary when test sample combus-tion in the normal temperature.
*KEPCO Standard criteria(ES�6145�0019, Graph.7)*More than 30 of OI value(Oxygen Index, OxygenIndex value)
Bunched Cable VerticalFlame SpreadTesterVFT-716
KS C IEC60332-3-24
It measures to test for flame spread,propagation characteristics for a singlevertical insulated wire or cable and de-fine of vertical arrangement fire spreadby electric or optical when cable isarrange vertically.(If added as option, Heat Release Rate(HRR) and Smoke Production Rate (SPR)could be measured)
*KEPCO_Standard for cablePurchasing (KS IEC 60502�1):Do not combustion more than2.5m of distance from burner.
Test on Gas Evolvedduring combustion ofelectric cables tester,Cable Halogen, PH &Conductivity Tester
HCT-717
IEC 60754-1&2,
KS C IEC60754-1&2
Measures gas volume of Halogen Acid(IEC 60754�1), pH concentration(PHMeter, Hydrogen ions, IEC 60754�2),Conductivity(IEC 60754�2) and etc froma wire (cable) by radiant heat in theTube Furnace (IEC 60754�1: 800°c, IEC60754�2: 950°c)
*KEPCO_ Standard for cablepurchasing (KS IEC 60502�1):(Hydrogen chloride gas pro-duction rate) less than 0.5%of HCI gas production/ (Hy-drogen Ion concentration andconductivity) more than PH4.3, and less than Conduc-tivity10μs/mm
I. Instrument List for Domestic (Korea)Instrument List by Class
No. Criteria TestingType Picture Name Starndard Test Overview Evaluation Criteria
2
KEPCOES6145�0019
Bunched Cable VerticalFlame
Spread TesterVFT�716
KS C IEC60332-3-24
It measures to test for flame spread,propagation characteristics for a singlevertical insulated wire or cable and de-fine of vertical arrangement fire spreadby electric or optical when cable isarrange vertically. (If added as option,Heat Release Rate (HRR) and SmokeProduction Rate (SPR) could be meas-ured)
*The cable purchasing stan-dard of Korea Electric PowerCorporation (KS IEC 60502�1):Shall not exceed to burn 2.5mfrom burner.
OygenIndexTest
Oxygen Index TesterLimited Oxgen Index
TesterLOI�404, LOI�P04
ASTM D2863,
ISO 4589�2,NES 714
LOI (Limited Oxygen Index tester)measures minimum oxygen concentra-tion as necessary when test samplecombustion in the normal temperature.
‐ KEPCO(Korea Electric PowerCorporation) Standard(ES�6145�0019, Graph 7)
‐ OI (Oxygen Index Rate) shallbe more than 30.
Test on Gas Evolvedduring
combustion of electriccablestester
Cable Halogen, PH &Conductivity Tester
HCT�717
Measures gas volume of Halogen Acid(IEC 60754�1), pH concentration(PHMeter, Hydrogen ions, IEC 60754�2),Conductivity(IEC 60754�2) and etc froma wire (cable) by radiant heat in theTube Furnace (IEC 60754�1: 800°c, IEC60754�2 : 950°c)
‐ KEPCO Purchasing standard(KS IEC 60502�1): (HydrogenChloride Gas Release Rate)HCI Gas release rate: lessthan 0.5% / (Hydrogen IonConcentration and Conduc-tivity) more than PH 4.3, andless than 10μs/mm
IEC 60754-1
IEC 60754-2
Non�ToxicityTest
CombustionGas
CorrosivenessTest
67/FIRE ENGINEERING & SCIENCE TECHNOLOGY
No. Criteria TestingType Picture Name Starndard Test Overview Evaluation Criteria
2
KEPCOES6145�0019
Smoke BoxSmoke Density Cham-
ber,SB�501, SB�P01
ASTM E662
(flamingmode)
Measures optical density of smokegenerated from test sample when testsample of certain thickness is exposedto heat source or fire in a chamber.
‐ KEPCO(Korea Electric PowerCorporation) Standard(ES�6145�0019, Graph 7)
‐ Dm (Density max, maximumvalue of Smoke density): lessthan 150
3KEPCOES6145�0034
OygenIndexTest
Oxygen Index TesterLimited Oxgen Index
TesterLOI�404, LOI�P04
ASTM D2863, ISO4589�2,NES 714
LOI(Limited Oxygen Index tester)measures minimum oxygen concentra-tion as necessary when test samplecombustion in the normal temperature.
‐ KEPCO (Korea ElectricPower Coporation) Standard(ES�6145�0019, Graph 7)
‐ OI (Oxygen Index, OxygenIndex value) is more than 30.
I. Instrument List for Domestic (Korea)Instrument List by Class
No. Criteria TestingType Picture Name Starndard Test Overview Evaluation Criteria
4KS CIEC
60502�1
Fire Re-sistanceTest
Single Vertical FlameSpread TesterSVF�938
KS C IEC60332�1
FESTEC’s Single Vertical Flame Spread Testeris included in IEC 60332�1, IEC 60695�2�4�0 & 1standards. This test use for method requires aset volume Chamber in standardized for sourceof ignition in electrical or optical, make standstraight of wires or cables vertically for thevertical arrange flame spread of the equipment.
When between bottom of upperholder and burning start pointdistance is over 50mm, it is pass.But, when it spread down over540mm from bottom of upperholder, it is fail.
5KS CIEC
60502�1
FireResist-anceTest
Bunched CableVertical FlameSpread TesterVFT-716
KS C IEC60332-3-24
It measures to test for flame spread,propagation characteristics for a singlevertical insulated wire or cable and de-fine of vertical arrangement fire spreadby electric or optical when cable isarrange vertically.(If added as option, Heat Release Rate(HRR) and Smoke Production Rate (SPR)could be measured)
*The cable purchasing stan-dard of Korea Electric PowerCorporation (KS IEC 60502�1):Shall not exceed to burn 2.5mfrom burner.
SmokeDensityTest
3 Meter CubeSmoke Density
TesterCSD-S14, CSD-W14
IEC61034
FESTEC’s 3Meter Smoke Density Tester is thetesting equipment measuring thesmoke gen-erated when the cable or optical cable isplaced horizontally and burn under definite fireresource in the specified condition (3㎥ cham-ber required by IEC 61034).
*The Cable Purchasing Stan-dard of Korea Electric PowerCorporation (KS IEC 60502�2):light transmittance is morethan 60%.
Test on GasEvolved duringcombustion ofelectric cables
tester,Cable Halogen,PH & Conductivity
TesterHCT-717
IEC 60754�1&2 Tester measures gasvolume of Halogen Acid (IEC 60754�1),pH concentration (PH Meter, Hydrogenions, IEC 60754�2), Conductivity(IEC60754�2) and etc from a wire (cable) byradiant heat in the Tube Furnace (IEC60754�1: 800°c, IEC 60754�2: 950°c)
*The Cable Purchasing Stan-dard of Korea Electric PowerCorporation (KS IEC 60502�1):(Hydrogen chloride gas gen-eration rate) Hydrogen chlo-ride (HCI) 0.5% or less of gasgeneration rate/ (Hydrogenion concentration and con-ductivity) PH 4.3 or higher,conductivity 10μs/ mm or less)
IEC 60754-1
IEC60754-2
KS C IEC60684-2
AcidicGasContentTest
Hydrogen IonConcentration(pH) andConductivityTest
FluorineContentTest
No. Criteria TestingType Picture Name Starndard Test Overview Evaluation Criteria
6KS CIEC60840
Single Vertical FlameSpreadTester,SVF�938
KS C IEC60332-1
FESTEC’s Single Vertical Flame SpreadTester is included in IEC 60332�1, IEC60695�2�4�0 & 1 standards. This test usefor method requires a set volumeCham-ber in standardized for source ofignition in electrical or optical, makestand straight of wires or cables verti-cally for the vertical arrange flamespread of the equipment.
When between bottom of upperholder and burning start pointdistance is over 50mm, it ispass.But, when it spread down over540mm from bottom of upperholder, it is fail.
7 IEC62067
Testunderfirecondi-tions
IEC 60332-1
8
Performance TestTechnology Stan-
dard ofFire Resistance
Cable(1998)
Smoke BoxSmoke DensityChamber,
SB 2005, SmokeDensity TesterSB�501, SB�P01
ASTM E662,
BSI 6401,ISO 5659,NES 711,NFPA 258
Smoke Box measures optical density ofsmoke generated from test samplewhen test sample of certain thicknessis exposed to heat source or fire in achamber.
Performance Test TechnologyStandard of Fire ResistanceCable (1998): Korea Fire Institute of Indus-try & Technology(KFI)
� Smoke Density Test: Accordingto Section 5, during test smokedensity should be less than150Dm.
� Oxygen Index Test: Accordingto Section 7, during test Oxy-gen Index should be morethan 25%.
� Combustion Gas CorrosionTest: According to Section 6,when test voltage is put onSpecimen after 12 hours fromTest, Fuse should not beshort�cut.
Limited OxygenIndex Tester
LOI-404, LOI-P04
KS M ISO4589�2
LOI(Limited Oxygen Index tester)measures minimum oxygen concentra-tion as necessary when test samplecombustion in the normal temperature.
89/FIRE ENGINEERING & SCIENCE TECHNOLOGY
No. Criteria Picture Name Starndard Test Overview Evaluation Criteria
9
Performance TestTechnology Stan-
dard ofFire Resistance
Cable(1998)
Test on Gas Evolvedduring
combustion of elec-tric cables tester,Cable Halogen,PH & Conductivity
TesterHCT�717
IEC 60754�1&2, KS CIEC 60754�1&2
IEC 60754�1&2 Tester measures gasvolume of Halogen Acid (IEC 60754�1),pH concentration (PH Meter, Hydrogenions, IEC 60754�2), Conductivity(IEC60754�2) and etc from a wire (cable) byradiant heat in the Tube Furnace (IEC60754�1: 800°c, IEC 60754�2: 950°c)
The Cable Purchasing Standardof Korea ElectricㅡPower Cor-poration (KS IEC 60502�1): (Hy-drogen chloride gas generationrate) Hydrogen chloride (HCI)0.5% or less of gas generationrate/ (Hydrogen ion concentra-tion and conductivity) PH 4.3 orhigher, and less than conduc-tivity 10μs/ mm
10
Cable and insu-lated wire
for low�toxicityFire
resistance poly-olefin
voltage control(KS C 3341)
Smoke BoxSmoke DensityChamber
SB�501, SB�P01
ASTM E662,
BSI 6401,ISO 5659,NES 711,NFPA 258
Smoke Box measures optical density ofsmoke generated from test samplewhen test sample of certain thicknessis exposed to heat source or fire in achamber. Cable and insulated wire for
low�toxicity fire resistance poly-olefin voltage control� Application Scope: This stan-dard is provide to cable forcross�linkage polyethylene low�toxicfire resistance polyolefinsis�voltage control and insu-lated wire for low�toxicity fireresistance polyolefin.
Test on GasEvolved during
combustion of elec-tric cables tester,Cable Halogen,
PH &Conductivity Tester
HCT�717
IEC 60754�1&2, KS CIEC 60754�1&2
IEC 60754-1&2 Tester measures gasvolume of Halogen Acid (IEC 60754-1),pH concentration (PH Meter, HydrogenIons, IEC 60754-2), Conductivity (IEC60754-2) and etc from a wire (cable) byradiant heat in the Tube Furnace (IEC60754-1: 800°c, IEC 60754-2: 950°c)
I. Instrument List for Domestic (Korea)Instrument List by Class
No. Test Specifications(Test Regulation) Picture Name Starndard Test Overview Evaluation Criteria
1
MLTM(Ministry ofLand,
Transport and Mar-itime Affairs) CityRail/Vehicle
Safety Standard(Article 10 Section 2)
Smoke BoxSmoke DensityChamber
SB�501, SB�P01
ASTM E 662,BSI 6401,ISO 5659-2,NES 711,NFPA 258
Smoke Density Testermeasures optical densityof smoke generated fromtest sample when testsample of certain thick-ness is exposed to heatsource(2.5W/c㎡, 25㎾/㎡)or fire in a chamber.
*MLTM(Ministry of Land, Transport andMaritime Affairs) City Rail Car safetyStandard
� Fire safety testing standard and Stan-dard for vehicle's interior and facili-ties(Article 10 Section 2)
� Test Standard : Oxygen index(TestStandard on International Organizationfor Standardization), Flame Propaga-tion(Test Standard on InternationalOrganization for Standardization),Smoke Density(Test Standard onAmerican Society for Testing Materials),Smoke Toxic(BIS)
� Test Contents: Interial Panel, Chair(Cover, Cushion, Body), Tunnel Con-nection, Insulator*Refer to 2 of Fire Safety testing methodand Standard for Vehicle interior
Oxygen Index TesterLimited Oxygen Index
TesterLOI�404, LOI�P04
ASTM D 2863,ISO 4589-2,NES 714
LOI(Limited Oxygen Indextester) measures minimumoxygen concentration asnecessary when testsample combustion in thenormal temperature.
Spread of FlameTesterIMO�609
ISO 5658,ASTM E 1317,IMO Resolution
A. 653
It is used to evaluatecombustion characteristicsof building materials andship materials, and meas-ures spread rate of flame,heat for ignition by dis-tances and CFE (CriticalFlux at Extinguishmen),and total heat release.
1011/FIRE ENGINEERING & SCIENCE TECHNOLOGY
3. Transportation, Railway
I. Instrument List for Domestic (Korea)Instrument List by Class
4. UN Hazard Test
No. Test Specifications(Test Regulation) Picture Name Starndard Test Overview Evaluation Criteria
1 UN HAZARD TEST
Time & PressureTesterTP-823
UN HazardTest,
EU REACH
It measures ignition effectsof hazardous materials(explosive materials) underairtight conditions by UNHazard Control. *UN Hazard Test(UN Transportation reg-
ulatory requirements)� UN Transportation standards: safety�re-lated standards for shipment or luggage
Flame DurabilityTesterFDT-824
KS M ISO9038,
EU REACH
It measures to evaluatecontinuous combustion ofliquid hazardous materialif the material is heated at60.5℃ and 75℃ and isexposed to flame.
5. Petroleum Products
No. Test Specifications(Test Regulation) Picture Name Starndard Test Overview Evaluation Criteria
1Flashpoint
characterization ofpetroleum products
Cleveland Open CupAuto FlashPoint Tester
Cleveland OpenTesterCOC�621
KS M 2010,ISO 2592
It automatically measuresflash point and ignitionpoint of petroleum prod-ucts, whose flash point isover 80℃, except for crudeoil and oil fuel. *Korea Industrial Standard: crude oil
and petroleum products to flash pointtesting (KS M 2010)
Tag Closed Cup AutoFlash Point Tester
TAG�621KS M 2010,ASTM D 56
It automatically measuresflash point and ignitionpoint of crude oil and pe-troleum products whoseflash point is below 93℃.
No. Test Specifications(Test Regulation) Picture Name Starndard Test Overview Evaluation Criteria
1
New RenewableEnergy _
Detail judging crite-ria for Facility
UL 94- AVH Chamber,
Plastic CombustibilityTester
UL-511, UL-P11
UL 94,ASTM D 5048,KS M 3015, KS M 3305, KS M 3809, KS MISO 9772
UL 94 measures the combustionproperties (after flame, after glow) byburner (H�5025 UL tirrill burner) whentest sample combusts in cham-ber's internal volume of 0.864㎥and is installed internal light to ob-serve the specimen's propertiesand has ventilating opening withemission fan to remove the com-bustion gas.
*New Energy and Renewable EnergyDevelopment Use Act: Judging criteriaof facility certificate Section 2 from En-forcement Regulations Article 7 andSection 1 [Annex 2]
Erosion TrackingIndex Tester
ETT-S33, ETT-033
KS C IEC60587,ASTM D 2303,IEC 60587
Erosion Tracking Testermeasures the resistance totracking and erosion by usingliquid pollutants and inclinedplane specimens.
Hot Wire Coil IgnitionTesterHWC-038
KS C IEC60695-2-20
Hot wire coil ignition testermeasures the specimen’signition time during hotcoil is heated electrically.
Radiant Panel FlameSpread TesterRFS-929
ASTM E 162,ASTM D 3675
The Radiant Panel Flame SpreadTester is an equipment usinggas ignited Radiant heat panelto test the surface combustibilityof Building product (ASTM E 162)and cellular plastics (ASTM E3675), Radiant Panel Index (Is) ismeasured by the flameradio�waves, Critical HeatFlux,(CHF) and Heat ReleaseRate(kW/㎡).
Solar Cell & RoofSpread of Flame &Burning Brand
TesterSCF-930
UL 790, UL 1730,IEC 61730-2Annex.A,
ASTM E 108-04, KS C IEC61730-2
This equipment virtuallysimulates an external fireto evaluate the resistanceof the roof and otherphysical elements of fire.
1213/FIRE ENGINEERING & SCIENCE TECHNOLOGY
6. New Renewable Energy (IEC 61730-1&2)
I. Instrument List for Domestic (Korea)Instrument List by Class
7. Fire Protection
No. Test Specifications(Test Regulation) Picture Name Starndard Test Overview Evaluation Criteria
1
Legislation aboutbuilding
interior decorativematerials
(Fire Services Act.Section 20)
Smoke BoxSB�501, SB�P01
ASTM E 662,BSI 6401,ISO 5659-2,NES 711,NFPA 258
Smoke Box measures op-tical density of smokegenerated from test sam-ple when test sample ofcertain thickness is ex-posed to heat source orfire in a chamber.
*Fire Service Act. 20 (Criteria fire re-sistance material and performance offire resistance) section 5: 400 of Max-imum smoke production
2
Qualification Ceri-teria of selfrespi-
ratoryfor Fire evacuation(Chapter2, Section
7~9)
Respiratory Protec-tive Device TesterOperation perform-ance TesterRPD-826
EN 13794,EN 400,EN 1146,EN 145
The operation performancetester is a system to compre-hensively perform the EU stan-dard test of the respiratoryprotective apparatus. It system-izes the actual process ofhuman breathing to check thevalid operating time of respira-tory protective device bymeasuring oxygen consumptionand carbon dioxide eliminationcapacity using a certain amountof air intake and exhaust. It canalso help assessing whetherthe apparatus can ensuresafety from toxic gas in case offire.
*Qualification Criteria of self�respiratory for Fireevacuation
� Chapter. 2 Section.7, Operation PerformanceTest: during inhalation, less than 3% of CO2concentration and 1.75l of inhalation and ex-piration per 20 min.When inhalation, relative humidity should be85%.
� Chapter2 Section 8, Inhalation resistance: in-halation resistance�750pa, 2l of inhalation andexhalation 25time as per 1 min.
� Chapter2, Section 9, exhalation resistance:exhalation resistance� 750Pa, 2l of inhalationand exhalation 25 times as per 1 min.
3
Notification fromNEMA(NationalEmergencyManangementAgency)
Ceriteria for per-formance offire retardancy
45 Degree Flammability Tester, 45 Degree Tester, Fire Retardant
Performance TesterKS F 2819
KS F 2819,ASTM D1230, NFPA702, CA TB117, KS F2621, KS F8081, KOFIS1001, JIS
L1091 A-1, A-2, B, D
It measures combustioncharacteristics such asAfter Glow and AfterFlame of test specimeninstalled at a 45�degreeangle.
*Notification from NEMA Section2005�65, Fire retardancy performancestandard (KOFIS 1001): measurementfire retardancy performance of Ply-wood, Carpet, Thin sheet, thick sheetand etc.After combustion for 1�2 minutes withconnectburner flame to specimen, itmeasures char area, char length, afterflame time, after glow time and etc.
1415/FIRE ENGINEERING & SCIENCE TECHNOLOGY
II. Instrument List for International
II. Instrument List for International
1. Industrial Section1.1 European CPD : Construction Products Directive1.1.1. Wall, Ceiling, Flooring and Linear Pipe Thermal Insulation Products
No. Standard Picture Product Name Descriptions
1 EN 13823 Single Burning ItemsSBI-606
European’s the evaluation of fire�resistance performance ofbuilding materials, measures Fire Growth Rate (FIGRA),Smoke Growth Rate(SMOGRA), oxygen consumption, CO,CO2 production, mass loss rate and so on.
2 EN ISO 1182 Non-Combustibility TesterNC-502, NC-P02
Non�Combustibility Tester measures incombustibility andcombustibility of uniform building material and non�uniformbuilding material of actual element.
3 EN ISO 11925 Ignitability test Reaction to fire test_Ignitability of building products subjectedto direct impingement of flame
4 EN ISO 9239 Flooring Radiant Panel TesterFRP-827
Flooring Radiant Panel Tester can measure critical heat flux(CHF) which observed flame spread length transformersKw/㎡ using by heat streamline velocity. And if specimentakes more than 30 minute testing time, it could be recorda flame extinction time and the farthest of flame spread, thentransforms it’s into CHF.
Instrument List by Class
1617/FIRE ENGINEERING & SCIENCE TECHNOLOGY
1.1.2 Electric Cables
No. Standard Picture Product Name Descriptions
1 EN 50399 Vertical Flame Spread Tester withFIPPEC project
This is based on IEC 60332�3 with the heat release facilities(measuring station) and Heat Release Facilities (MeasuringStation) is added.
2 EN 60332-1-2 Single Vertical Flame Spread TesterSVF-938
Single Vertical Flame Spread Tester included IEC 60332�1and IEC 60695�2�4�0 &1 is used for method requires a setvolume Chamber in standardized for source of ignition inelectrical or optical, make stand straight of wires or cablesvertically for the vertical arrange flame spread of the equip-ment.
3 EN 61034 3 Meter Cube Smoke Density TesterCSD-S14, CSD-W14
FESTEC’s 3 Meter Smoke Density Tester is the testingequipment measuring the smoke generated when the cableor optical cable is placed horizontally and burn under def-inite fire resource in the specified condition (3㎥ chamberrequired by IEC 61034).
II. Instrument List for InternationalInstrument List by Class
1.2 European Railway1.2.1. Structural Products, incl. Flooring
No. Standard Picture Product Name Descriptions
1 ISO 5658-2 Spread of Flame TesterIMO-609
IMO is used to evaluate combustion characteristics of building materialsand ship materials and measures spread rate of flame, flame for ig-nition by distances, CFE (Critical Flux at Extinguishment) and total heatrelease. This test method is originated from ISO 5658�2 (Reaction tofire tests– Spread of flame� Part 2 Lateral spread on building productsin vertical configuration) and measures combustion characteristics ofvertical specimen (155㎜X800㎜).
2 ISO 5660-1 Cone CalorimeterCC-105, CC-P05
Cone Calorimeter measures heat release rate(H.R.R), smokerelease, ignition time, oxygen consumption, carbon monoxideand carbon dioxide generation and mass loss rate whenspecimen is exposed to resource of conical heater.
3 EN ISO 9239-1 Flooring Radiant Panel TesterFRP-827
This surface of the material spread flame tester (ISO 9239,Flooring Radiant Panel Tester) is test method that formalreflected spread of flame on flooring material back�draftcondition when fire on building happened flame at com-partment or room adjacent, or high temperature gas radiatedto flooring surface a hot radiation heat accumulated at upperof midway during a fire at an early growing step.
4 ISO 5659-2
ISO 5659 Assembly TesterModified apparatus by ISO 5660 &ASTM E 662, High-TemperatureSimulation Tester,ISO 5659-1 ,
ISO 5659-2
FESTEC’s ISO 5659 is to measure and observe shape oftest specimen by radiation heat of Conical Heater, andmeasures ignition time and mass loss rate.
5 EN ISO 11925-2 Ignitability test Reaction to fire tests - Ignitability of building products subjected to direct impingement of flame
1819/FIRE ENGINEERING & SCIENCE TECHNOLOGY
1.2.2 Seats
No. Standard Picture Product Name Descriptions
1 ISO 9705
Room Corner Tester,Medium scale calorimeter : Avg,
max 3㎿,Furniture Calorimeter
RCT-607
Room Corner Tester (RCT), as ISO’s the evaluation of fir-eresistance performance of building materials, measuresheat release rate (H.R.R), smoke generation rage, oxygenconsumption, CO, CO2 production and so on.
2 ISO 5660-1 Cone CalorimeterCC-105, CC-P05
Cone Calorimeter measures heat release rate(H.R.R), smokerelease, ignition time, oxygen consumption, carbon monoxideand carbon dioxide generation and mass loss rate whenspecimen is exposed to resource of conical heater.
3 ISO 5659-2 Smoke Box,SB-501, SB-P01
Smoke Box (Smoke Density Chamber) measures opticaldensity of smoke generated from test sample when testsample of certain thickness is exposed to heat source orfire in a chamber.
1.2.3. Cables
No. Standard Picture Product Name Descriptions
1 EN 60332-1-2 Single Vertical Flame Spread TesterSVF-938
Single Vertical Flame Spread Tester included IEC 60332�1and IEC 60695�2�4�0 & 1 is used for method requires a setvolume Chamber in standardized for source of ignition inelectrical or optical, make stand straight of wires or cablesvertically for the vertical arrange flame spread of theequipment.
II. Instrument List for InternationalInstrument List by Class
1.2.4. Non-Listed Items
No. Standard Picture Product Name Descriptions
1
ASTM D 2863, ISO4589-2,NES 714,
ASTM D 2863, ISO 4589-3, NES 715
Limited & Temperature OxygenIndex Tester
LOI-404, LOI-P04,TOI-504, TOI-P04
FESTEC’s LOI(Limited Oxygen Index tester) measuresminimum oxygen concentration as necessary whenspecimen combustion. TOI (Temperature Oxygen IndexTester) measures temperature index of specimen by heatedmixing gases on temperature up to 400℃ in the atmosphereoxygen concentration.
2
ASTM E 662,BSI 6401,ISO 5659-2,NES 711,NFPA 258
Smoke Box,Smoke Density Chamber
SB-501, SB-P01
Smoke Box (Smoke Density Chamber) measures opticaldensity of smoke generated from test sample when testsample of certain thickness is exposed to heat source orfire in a chamber.
3 NF X 70-100 NF X 70-100
NF X 70�100 is the test method to analysis for gas with atube type combustion chamber and furnace method. In thespecific condition of heat damage as expose to air bymaterial or mixture procedure of material, materials isanalyzed at the same time to occurred and exhausted.
2021/FIRE ENGINEERING & SCIENCE TECHNOLOGY
1.3 European Roofing Products
No. Standard Picture Product Name Descriptions
1 ENV 1187 Test 1 With burning brands
The method for external fire exposure to roofs_with burningbrands, with burning brans and wind, with burning brandsand supplementary radiant heat.
2 ENV 1187 Test 2 With burning brands and wind
3 ENV 1187 Test 3 With burning brands, wind andsupplemetary radiant heat
4 ENV 1187 Test 4With 2 stages incorporating burningbrands, wind and supplementary
radiant heat
II. Instrument List for InternationalInstrument List by Class
1.4. U.S. Transportation1.4.1 Test Methods
No. Standard Picture Product Name Descriptions
1 Large Scale MattressFire Test
Room Corner Tester,Medium scale calorimeter : Avg,
max 3㎿,Furniture Calorimeter
RCT-607
Room Corner Tester (RCT), as ISO’s the evaluation of fir-eresistance performance of building materials, measuresheat release rate (H.R.R), smoke generation rage, oxygenconsumption, CO, CO2 production and so on.
2 ASTM E 662 Smoke Box, Smoke Density ChamberSB-501, SB-P01
Smoke Box (Smoke Density Chamber) measures opticaldensity of smoke generated from test sample when testsample of certain thickness is exposed to heat source orfire in a chamber.
3 ASTM E 162 Radiant Panel Flame Spread TesterRFS-929
The Radiant Panel Flame Spread Tester is an equipmentusing gas ignited Radiant heat panel to test the surfacecombustibility of Building product (ASTM E 162) and cellularplastics (ASTM E 3675), Radiant Panel Index (Is) is measuredby the flame radio�waves, Critical Heat Flux,(CHF) and HeatRelease Rate(kW/㎡).
1.4.2 Motor Vehicles
No. Standard Picture Product Name Descriptions
1 ASTM E 1537
Room Corner Tester,Medium scale calorimeter : Avg,max 3㎿, Furniture Calorimeter
RCT-607
Room Corner Tester (RCT), as ISO’s the evaluation of fir-eresistance performance of building materials, measuresheat release rate (H.R.R), smoke generation rage, oxygenconsumption, CO, CO2 production and so on.
2223/FIRE ENGINEERING & SCIENCE TECHNOLOGY
1.4.3 Shipping
No. Standard Picture Product Name Descriptions
1 ASTM E 1317 Spread of Flame TesterIMO-609
IMO is used to evaluate combustion characteristics ofbuilding materials and ship materials and measures spreadrate of flame, flame for ignition by distances, CFE (CriticalFlux at Extinguishment) and total heat release. This testmethod is originated from ISO 5658�2 (Reaction to fire tests–Spread of flame� Part 2 Lateral spread on building productsin vertical configuration) and measures combustioncharacteristics of vertical specimen (155㎜X800㎜).
2 ISO 1182 Non-Combustibility TesterNC-502, NC-P02
Non�Combustibility Tester measures incombustibility andcombustibility of uniform building material and non�uniformbuilding material of actual element.
3 ISO 5659-2Smoke Box,
Smoke Density ChamberSB-501, SB-P01
Smoke Box (Smoke Density Chamber) measures opticaldensity of smoke generated from test sample when testsample of certain thickness is exposed to heat source orfire in a chamber.
4 UL 1685Fire Resistance Assemblies TesterIEEE 1202, IEEE 383, UL1685
FRA-815, FRA-P15
FESTEC’s Fire Resistance Assemblies Tester is included inboth the IEEE 1202 and IEEE 383 standards. This test methodis proceed in a chamber with a set volume for 20minutes.During the 20 minutes, a sample cable is ignited withtheoretically 20㎾(70,000Btu/hr) flame using an ignitionsource fixed in a vertical position. This equipment evaluatesa spread of flame of single core cable or multi core cable.
II. Instrument List for InternationalInstrument List by Class
1.5. Plastics
No. Standard Picture Product Name Descriptions
1 ISO 5660,ASTM E 1354
Cone CalorimeterCC-105, CC-P05
Cone Calorimeter measures heat release rate(H.R.R), smokerelease, ignition time, oxygen consumption, carbon monoxideand carbon dioxide generation and mass loss rate whenspecimen is exposed to resource of conical heater.
2
BS 6401ASTM E 662ISO5659NES711
Smoke Box,Smoke Density Chamber
SB-501, SB-P01
Smoke Box (Smoke Density Chamber) measures opticaldensity of smoke generated from test sample when testsample of certain thickness is exposed to heat source orfire in a chamber.
3 ISO 4589-2ASTM D 2863
Limited & Temperature OxygenIndex Tester
LOI-404, LOI-P04,TOI-504, TOI-P04
FESTEC’s LOI(Limited Oxygen Index tester) measuresminimum oxygen concentration as necessary whenspecimen combustion. TOI (Temperature Oxygen IndexTester) measures temperature index of specimen by heatedmixing gases on temperature up to 400℃ in the atmosphereoxygen concentration.
4 ISO 4589-3
5 UL 94UL 94- AVH Chamber,
Plastic Combustibility TesterUL-511, UL-P11
UL 94 measures the combustion properties (after flame,after glow) by burner (H�5025 UL tirrill burner) when testsample combusts in chamber's internal volume of 0.864㎥and is installed internal light to observe the specimen'sproperties and has ventilating opening with emission fan toremove the combustion gas.
2425/FIRE ENGINEERING & SCIENCE TECHNOLOGY
No. Standard Picture Product Name Descriptions
6 UL 1581 UL 1581Vertical Wire Flame Chamber
FESTEC’s VW�1(Vertical�Specimen) Flame Tester is appliedstandard flame to specimen as 5 times for 15 sec. and itaccordance with UL 1581 perfectly.
7 ASTM E 162 Radiant Panel Flame Spread TesterRFS-929
The Radiant Panel Flame Spread Tester is an equipmentusing gas ignited Radiant heat panel to test the surfacecombustibility of Building product (ASTM E 162) and cellularplastics (ASTM E 3675), Radiant Panel Index (Is) is measuredby the flame radio�waves, Critical Heat Flux,(CHF) and HeatRelease Rate(kW/㎡).
8 IEC 60587ASTM D 2303
Erosion Tracking TesterETT-S33, ETT-033
Erosion Tracking Tester measures the resistance to trackingand erosion by using liquid pollutants and inclined planespecimens. This tester can be evaluated resistance to track-ing and erosion of electrical insulation materials used undersevere ambient conditions and has two kinds type test waywhich are constant tracking voltage and stepwise trackingvoltage is enable.
1.6. Aviation
No. Standard Picture Product Name Descriptions
1 BS 6401
Smoke Box,Smoke Density Chamber
SB-501, SB-P01
Smoke Box (Smoke Density Chamber) measures opticaldensity of smoke generated from test sample when testsample of certain thickness is exposed to heat source orfire in a chamber.
2 ASTM E 662
3 ISO 5659
4 NES 711
II. Instrument List for InternationalInstrument List by Class
2. FTP Code, Fire Test Procedure
No. Standard Picture Product Name Descriptions
1
Part 1: Non-com-bustibilitytest-ISO 1182
(Non-combustibilityTester)
Non-Combustibility TesterNC-502, NC-P02
Non�Combustibility Tester measures incombustibility andcombustibility of uniform building material and non�uniformbuilding material of actual element.
2
Part 2: Smoke andtoxicitytest_
ISO 5659-2(Smoke DensityChamber)
Smoke Box,Smoke Density Chamber
SB-501, SB-P01
Smoke Box (Smoke Density Chamber) measures opticaldensity of smoke generated from test sample when testsample of certain thickness is exposed to heat source orfire in a chamber.
3
Part 3: Test for"A","B" and "F"
Class divisions_ISO 834(Building Construc-tion VerticalFire Resistance
Tester)
Building Construction(Fire Door and others)Fire Resistance
Tester,Vertical Furnace,Horizontal Furnace,BRF�125, BRF�225
Reaction according to Fire test� it measures reaction ofbuilding construction from direct flame to building material.
4
Part 4: Test for firedoor
control systems_ISO834 and
additional fire doorset
equipment
It evaluate to durability with exposed product and materials to hightemperature of vertical (or horizontal) directions.It measures for performance of building construction in standard fireconditions.It follows for standard requirements, performance condition of vertical(or horizontal) resistance structure, vertical (or horizontal) non�resis-tance structure and fire protection door for building construction testmethod.
2627/FIRE ENGINEERING & SCIENCE TECHNOLOGY
No. Standard Picture Product Name Descriptions
5Part 5: Test for surfaceflammability_ISO 5658(Spread of Flame Tester)
Spread of Flame TesterIMO-609
IMO is used to evaluate combustion characteristicsof building materials and ship materials and meas-ures spread rate of flame, flame for ignition by dis-tances, CFE (Critical Flux at Extinguishment) and totalheat release. This test method is originated from ISO5658�2 (Reaction to fire tests–Spread of flame� Part2 Lateral spread on building products in verticalconfiguration) and measures combustion character-istics of vertical specimen (155㎜X800㎜).
6 Part 9: Test for beddingcomponents
Room Corner Tester,Medium scale calorimeter :
Avg,max 3㎿,
Furniture CalorimeterRCT-607
Room Corner Tester (RCT), as ISO’s the evaluationof fireresistance performance of building materials,measures heat release rate (H.R.R), smoke genera-tion rage, oxygen consumption, CO, CO2 productionand so on.
7
Part 10: Testfor firere-stricting
materials forhigh sppedcraft
Appendix 1: Fire tests sur-face materials on bulkheads,wall and ceiling linings, including their supportingstructure, of high-speed
craft
Appendix 2: Reaction to firetests heat release, smokeproduction and mass loss
rate for materialsused for furniture andOther components ofhigh-speed craft
Cone CalorimeterCC-105, CC-P05
Cone Calorimeter measures heat release rate(H.R.R),smoke release, ignition time, oxygen consumption,carbon monoxide and carbon dioxide generationand mass loss rate when specimen is exposed toresource of conical heater.
II. Instrument List for InternationalInstrument List by Class
3. IEC Standards : International Electro-technical Commission
No. Standard Picture Product Name Descriptions
1 IEC60502-1
Fireretar-dantTest
Single Vertical FlameSpread TesterSVF�938
Single Vertical Flame Spread Tester is used for methodrequires a set volume Chamber in standardized for source ofignition in electrical or optical, make stand straight of wiresor cables vertically for the vertical arrange flame spread ofthe equipment.
Vertical Flame SpreadTester
Bunched Cable VerticalFlame Spread Tester, IEC60332�3, KS C IEC 60332�
3�10, 21~25
Bunched Cable Vertical Flame Spread Tester is a series conformingto IEC 60332�3�10, KS C IEC 60332�3�21~25 (Category A~D) stan-dards. The test measures the expansion of vertical flame to theelectronically or optically vertical cable or wire using the standardignition source while supplying a certain amount of air to a chamberof a defined volume.
SmokeDensityTest
3M Cube Smoke DensityTester
CSD-S14, CSD-W14
3 meter cube smoke density tester measures smoke densityand transmission of cable when test sample is put horizontally andexposed to heat in the 3 meter cube chamber by IEC 61034.
Test on Gas Evolved duringcombustion of electric cables
tester,Cable Halogen, PH & Conduc-
tivity TesterHCT-717
IEC 60754�1&2 Tester measures gas volume of Halogen Acid(IEC 60754�1), pH concentration(PH Meter, Hydrogen ions,IEC 60754�2), Conductivity(IEC 60754�2) and etc from a wire(cable) by radiant heat in the Tube Furnace (IEC 60754�1:800°c, IEC 60754�2: 950°c)
AcidicGasContentTest
Hydrogen IonConcentration(pH) and
Conductivity Test
FluorineContentTest
2829/FIRE ENGINEERING & SCIENCE TECHNOLOGY
No. Standard Picture Product Name Descriptions
2 IEC 60840
IEC 60332-1Single Vertical Flame Spread Tester
Single Vertical Flame Spread Tester included IEC 60332�1and IEC 60695�2�4�0 & 1 is used for method requires a setvolume Chamber in standardized for source of ignition inelectrical or optical, make stand straight of wires or cablesvertically for the vertical arrange flame spread of theequipment.
3 IEC 62067
4 IEC 60331-11&21 Fire Resistance TesterCFR-818, CFR-P18
FESTEC’s IEC 60331�11 tester is used in test conditionswhere the basic flame temperature is at least 750℃ and teststhe cable exposed to the flame that needs to maintain thecircuit integrity.
5 IEC 60331-12&31 Fire Mechanical Shock TesterCFM-819, CFM-P19
This tester is used in test conditions where the basic flametemperature is at least 830℃ and tests the cable exposedto flame and mechanical shock that needs to maintain thecircuit integrity.
6 IEC 60587ASTM D 2303
Erosion Tracking TesterETT-S33, ETT-033
Erosion Tracking Tester measures the resistance to trackingand erosion by using liquid pollutants and inclined planespecimens. This tester can be evaluated resistance totracking and erosion of electrical insulation materials usedunder severe ambient conditions and has two kinds typetest way which are constant tracking voltage and stepwisetracking voltage is enable.
II. Instrument List for InternationalInstrument List by Class
No. Standard Picture Product Name Descriptions
7 IEC 60695-2-20 Hot Wire Coil Ignition TesterHWC-038
Hot wire coil ignition tester measures the specimen’s ignitiontime during hot coil is heated electrically.
8 BS 6387 Fire Resistance Water Spray Tester,CFW-820
It is a testing device that checks for the standard level ofcurrent in the cable, and also checks the cable’s resistancefor heat and water of the cable.
3031/FIRE ENGINEERING & SCIENCE TECHNOLOGY
4. UL ; Underwriter’s Laboratories
No. Standard Picture Product Name Descriptions
1 UL 94UL 94- AVH Chamber,
Plastic Combustibility TesterUL-511, UL-P11
UL 94 measures the combustion properties (after flame,after glow) by burner (H�5025 UL tirrill burner) when testsample combusts in chamber's internal volume of 0.864㎥and is installed internal light to observe the specimen'sproperties and has ventilating opening with emission fan toremove the combustion gas.
2 UL 790Solar Cell & Roof Spread of Flame &
Burning Brand TesterSCF-930
This equipment virtually simulates an external fire toevaluate the resistance of the roof and other physicalelements of fire, in order to qualify for the flame spreadexperiments (A~C class), in case of A 1.82m, B 2.4m and C3.9m. It is equipment to displacement of the testing materialand the exposure and falling of the roof structure.
3
UL 1685,UL 1581_1160, 1164,UL 2556 _ 9.6Method 2
Fire Resistance Assemblies TesterIEEE 1202, IEEE 383, UL1685
FRA-815, FRA-P15
FESTEC’s Fire Resistance Assemblies Tester is included inboth the IEEE 1202 and IEEE 383 standards. This test methodis proceed in a chamber with a set volume for 20 minutes.During the 20 minutes, a sample cable is ignited withtheoretically 20kW(70,000Btu/hr) flame using an ignitionsource fixed in a vertical position. This equipment evaluatesa spread of flame of single core cable or multi core cable.
4 UL 1581
UL 1581Section 1060 FT1/
Section1061 (Cable Flame) / Section 1080 (VW-1)
The cable is fixed vertically and fitted with a paper indicatorflag (p, 10×20mm). A Bunsen burner, fixed at an angle of20 ̊to the vertical, is used to apply the flame.
UL1581Section 1090 (H) / Section 1100 (FT2)
The cable is fixed horizontally with the Bunsen burner flameapplied vertically. The burner is angled 20 ̊from the ver-tical.The cotton wool (B) is lid out nest to the burner.
II. Instrument List for InternationalInstrument List by Class
No. Standard Picture Product Name Descriptions
5 UL 1685
UL1685Vertical Tray
One layer of cable is fixed to a ladder (quantity depends onthe cable diameter). The length of each sample is 2.44m.
Fire Resistance Assemblies TesterIEEE 1202, IEEE 383, UL1685
FRA-815, FRA-P15
This test method is proceed in a chamber with a set volumefor 20 minutes. During the 20 minutes, a sample cable isignited with theoretically 20kW(70,000Btu/hr) flame using anignition source fixed in a vertical position. This equipmentevaluates a spread of flame of single core cable or multicore cable. If user wants to measure H.R.R (Heat Release Rate), Smokedensity and so on, Heat Release Facility (additional part) isadoptable to this equipment.
6 UL 1666Bunched Cable Vertical Flame
Spread TesterVFT-716
The test measures the expansion of vertical flame to theelectronically or optically vertical cable or wire using thestandard ignition source while supplying a certain amountof air to a chamber of a defined volume.
3233/FIRE ENGINEERING & SCIENCE TECHNOLOGY
III. Instrument List by Param
eter
III. Instrument List by Parameter
No. Parameter Picture Product Name Standard Detail Description Evaluation Criteria
1Oxygen
consumptioncalorimeter
Cone CalorimeterCC-105, CC-P05
ISO 5660,ASTM E 1354,NFPA 264,BS 476 pt15
Cone Calorimeter measures heatrelease rate, smoke release, ignitiontime, oxygen consumption, carbonmonoxide and carbon dioxide gen-eration and mass loss rate whentest sample is exposed to resourceof conical heater.
� Radition to Specimen� Combustion Gas release rate/ Orifice constance� Ignition time and extinguishing time� Total oxygen consumsion rate/ Total Com-bustion Gas production rate
� Mass loss value and Mass loss rate� Heat release rate / Effective burning Heat� CO production rate/ CO2 production rate
Thermal Characteris-tic Analyser,
Modified apparatusby ISO 5660
TCA-205, TCA-P05,TCA-305, TCA-405,
ISO 5660-1,KS
F ISO 5660-1
Thermal Characteristic Analysermeasures ignition time, mass lossrate and specimen surface, middleand lower of radiant thermal whentest sample is exposed to resourceof conical heater by using0~100kW/㎡ of radiant heat.
� Ignition time and extingushing time� Mass loss value and Mass loss rate� Radiation temperature on specimen surface(infrared light temperauture sensor)
� temperature of specimen surface, middle andbottom
� Ignition time and combustion time accordingto oxygen concentration variation
Conical Heater 5Step Temperature
ControllerConical Heater 5Step TemperatureController, T/C5Step_CC, 5 StepTemperature Con-troller, ISO5660
ISO 5660Optionalpart-1
It measures behavior of combustionof specimen by change in conicalheater’s 5 heat flux, temperatureand temperature increasing timethough three stages by simulatingthe actual fire for the modified testmethods of ISO 5660 Test Method
� Measurement of Temperature variation(Display on screen as graph)
� It assists to Cone Calorimeter to meas-ure of calories according to 5 steps oftemperature
Single Burning ItemsSBI-606
EN 13823,BS
EN 13823
Single Burning Items measures heatrelease rate(FIGRA), smoke growthrate index (SMOGRA), oxygen con-sumption, CO and CO2 production,and mass loss rate per test meth-ods for European building materi-als.
� Average Heat Release Rate, Total Heat Re-lease Rate [THR (t)]
� Fire Growth Rate (FIGRA)� Fire Growth to side� RSPav (t)� Total Smoke Production Rate [TSP(t)]� Smoke Growth Rate [SMOGRA]� Total Smoke Production Rate [TSP600s]
Instrument List by Class
3435/FIRE ENGINEERING & SCIENCE TECHNOLOGY
No. Parameter Picture Product Name Standard Detail Description Evaluation Criteria
1Oxygen
consumptioncalorimeter
Room Corner Tester,Medium scalecalorimeter : Avg,
max 3,Furniture Calorimeter
RCT-607
ISO 9705, ISO13784, KS FISO 13784,ASTM E 1537,prEN 14390,ASTM E 603
Room Corner Tester measure heat re-lease rate, smoke growth rate index, oxy-gen consumption, and carbon monoxideand carbon dioxide production on thebasis of ISO standard test methods forconstruction materials, and is alsoconvertible into Furniture Calorimeter fortesting furniture.
� Heat Release Rate / Effective burning Heat� CO Production Rate / CO2 Production Rate� Total Oxygen consumption rate / Total Combus-tion Gas production rate
� Radiant heat to measure Flash Over� Ignition time and extinguishing time� Mass loss value and mass loss rate� Measurement for temperature variation to Roomentrance
Large ScaleCalorimeter,Industrial & realscale calorimeter :
Avg,Max. 10㎿LSC-608
ISO 9705, EN13823, ISO13784, NFPA286, NIST SP1007, IEC60332-3, EN45545, EN50399
Large Scale Calorimeter measuresfire (for example, fire from a ware-house, the whole office, furnitureand a car) likely to occur in theactual situation and its measurerange is up to 10㎿.
� Heat Release Rate� Smoke production rate� Soot mass� Consumption of O2, CO and CO2 yield� Other Toxic Gas by FT�IR
2HeatReleaseRate
Non-CombustibilityTester
NC-502, NC-P02
ISO 1182, KS FISO 1182, KS F 2271
Non�Combustibility Tester measuresincombustibility and combustibilityof uniform building material andnon�uniform building material of ac-tual element.
It measures for incombustibility andcombustibility of uniform building mate-rial and non�uniform building material ofactual element.
Spread of FlameTesterIMO-609
ISO 5658,ASTM E1317,IMO
ResolutionA.653
IMO is used to evaluate combustion char-acteristics of building materials and shipmaterials and measures spread rate offlame, flame for ignition by distances, CFE(Critical Flux at Extinguishment) and totalheat release. This test method is origi-nated from ISO 5658�2 (Reaction to firetests–Spread of flame� Part2 Lateralspread on building products in verticalconfiguration) and measures combustioncharacteristics of vertical specimen(155mmX800mm).
� Combustion Continued Heat� Average Combustion Continued Heat� Ignition Heat� During extinguishing, critical heat flux� Total heat release� Maximum Heat release
III. Instrument List by Param
eterInstrument List by Class
No. Parameter Picture Product Name Standard Detail Description Evaluation Criteria
2HeatReleaseRate
Large ScaleCalorimeter,
Industrial & real scalecalorimeter : Avg,Max. 10㎿LSC-608
ISO 9705, EN13823, ISO13784, NFPA
286,NIST SP1007, IEC60332-3, EN45545, EN50399
Large Scale Calorimeter measuresfire (for example, fire from a ware-house, the whole office, furnitureand a car) likely to occur in theactual situation and its measurerange is up to 10㎿.
� Heat Release Rate� Smoke production rate� Soot mass� Consumption of O2, CO and CO2 yield� Other Toxic Gas by FT�IR
Room Corner Tester,Medium scalecalorimeter : Avg,
max 3㎿,Furniture Calorimeter
RCT-607
ISO 9705, ISO13784, KS FISO 13784,ASTM E 1537,prEN 14390,ASTM E 603
Room Corner Tester measure heatrelease rate, smoke growth rateindex, oxygen consumption, andcarbon monoxide and carbon diox-ide production on the basis of ISOstandard test methods for con-struction materials, and is alsoconvertible into Furniture Calorime-ter for testing furniture.
� Heat Release Rate / Effective burning Heat� CO Production Rate / CO2 Production Rate� Total Oxygen consumption rate / TotalCombustion Gas production rate
� Radiant heat to measure Flash Over� Ignition time and extinguishing time� Mass loss value and Mass loss rate� Measurement for temperature variationto Room entrance
Cone CalorimeterCC-105, CC-P05
ISO 5660,ASTM E1354,
NFPA 264,BS 476 pt15
Cone Calorimeter measures heatrelease rate, smoke release, ignitiontime, oxygen consumption, carbonmonoxide and carbon dioxide gen-eration and mass loss rate whentest sample is exposed to resourceof conical heater.
� Radition to Specimen� Combustion Gas release rate/ Orifice con-stance
� Ignition time and extinguishing time� Total oxygen consumsion rate/ Total Com-bustion Gas production rate
� Mass loss value and Mass loss rate� Heat release rate / Effective burning Heat� CO production rate/ CO2 production rate
Single Burning ItemsSBI-606
EN 13823,BS
EN 13823
Single Burning Items measures heatrelease rate (FIGRA), smoke growthrate index (SMOGRA), oxygen con-sumption, CO and CO2 production,and mass loss rate per test meth-ods for European building materi-als.
� Average Heat Release Rate, Total HeatRelease Rate [THR (t)]
� Fire Growth Rate ( FIGRA)� Fire Growth to side� RSPav (t)� Total Smoke Production Rate [TSP(t)]� Smoke Growth Rate [SMOGRA]� Total Smoke Production Rate [TSP600s]
3637/FIRE ENGINEERING & SCIENCE TECHNOLOGY
No. Parameter Picture Product Name Standard Detail Description Evaluation Criteria
2HeatReleaseRate
Bunched Cable Vertical Flame SpreadTesterVFT-716
IEC 60332-3
Bunched Cable Vertical FlameSpread Tester is a series conform-ing to IEC 60332�3�10, KS C IEC60332�3�21~25 (Category A~D)standards. The test measures theexpansion of vertical flame to theelectronically or optically verticalcable or wire using the standardignition source while supplying acertain amount of air to a chamberof a defined volume
� Do not combustion from Burner morethan 2.5m.
EN 50399
3 SmokeProduction
Smoke Box,Smoke Density Cham-
berSB-501, SB-P01
ASTM E 662,BS 6401, ISO 5659,NES 711
Smoke Box (Smoke Density Chamber)measures optical density of smoke gen-erated from test sample when test sampleof certain thickness is exposed to heatsource(2.5W/c㎡, 25㎾/㎡ using by E 662furnace) or fire in a chamber. This testmethod is increasingly used in interiormaterial of rolling stock, low power in-combustible cable and interior film, etc.
Fire Service Act. 20 (Criteria fire resist-ance material and performance of fireresistance) section 5: 400 of Maximumsmoke production
Large ScaleCalorimeter,Industrial & realscale calorimeter :
Avg,Max. 10㎿LSC-608
ISO 9705,EN13823,ISO13784,NFPA286,NIST SP1007, IEC60332-3, EN 45545,EN 50399
Large Scale Calorimeter measuresfire (for example, fire from a ware-house, the whole office, furnitureand a car) likely to occur in theactual situation and its measurerange is up to 10㎿.
� Heat Release Rate� Smoke production rate� Soot mass� Consumption of O2, CO and CO2 yield� Other Toxic Gas by FT�IR
III. Instrument List by Param
eterInstrument List by Class
No. Parameter Picture Product Name Standard Detail Description Evaluation Criteria
3 SmokeProduction
Room Corner Tester,Medium scalecalorimeter : Avg,
max 3㎿,Furniture Calorimeter
RCT-607
ISO 9705, ISO13784, KS FISO 13784,ASTM E 1537,prEN 14390,ASTM E 603
Room Corner Tester measure heatrelease rate, smoke growth rateindex, oxygen consumption, andcarbon monoxide and carbon diox-ide production on the basis of ISOstandard test methods for con-struction materials, and is also con-vertible into Furniture Calorimeterfor testing furniture.
� Heat Release Rate / Effective burning Heat� CO Production Rate / CO2 ProductionRate
� Total Oxygen consumption Rate / TotalCombustion Gas Production Rate
� Radiant Heat to measure Flash Over� Ignition time and extinguishing time� Mass loss value and Mass loss Rate� Measurement for temperature variationto Room entrance
Cone CalorimeterLab' scale calorimeter :Avg, 10~500 KW/㎡,
CC2006, Cone Calorimeter
ISO 5660,ASTM E1354,
NFPA 264,BS 476 pt15
Cone Calorimeter measures heatrelease rate, smoke release, ignitiontime, oxygen consumption, carbonmonoxide and carbon dioxide gen-eration and mass loss rate whentest sample is exposed to resourceof conical heater.
� Radition to Specimen� Combustion Gas Release Rate/ Orificeconstance
� Ignition time and extinguishing time� Total Oxygen consumsion Rate/TotalCombustion Gas Production Rate
� Mass loss value and Mass loss Rate� Heat Release Rate / Effective burning Heat� CO Production Rate/ CO2 Production Rate
Flooring RadiantPanelTester
ISO 9239-1&2,ASTM E648,
ASTM E 970,NFPA 253,KS F
ISO 9239-1&2
Flooring Radiant Panel Tester canmeasure critical heat flux (CHF)which observed flame spreadlength transformers Kw/㎡ using byheat streamline velocity. And ifspecimen takes more than 30minute testing time, it could berecord a flame extinction time andthe farthest of flame spread, thentransforms it’s into CHF.
� Flame Spread Distance is changed tokW/㎡ to use Heat flux and measureCitical Heat Flux (CHF).
� For the product to have test time morethan 30min, flame extinugishing timeand flame spread is recorded to fardistance and change to Critical HearFlux (CHF)
� In case of required to smoke meas-urement, smoke density is measuredby penetration ratio of photometricsystem.
3839/FIRE ENGINEERING & SCIENCE TECHNOLOGY
No. Parameter Picture Product Name Standard Detail Description Evaluation Criteria
3 SmokeProduction
Large ScaleCalorimeter,
Industrial & real scalecalorimeter : Avg,Max. 10㎿LSC-608
ISO 9705, EN13823, ISO13784, NFPA286, NIST SP1007, IEC60332-3, EN 45545, EN 50399
Large Scale Calorimeter measuresfire (for example, fire from a ware-house, the whole office, furnitureand a car) likely to occur in theactual situation and its measurerange is up to 10㎿.
� Heat Release Rate� Smoke Production Rate� Soot Mass� consumption of O2, CO and CO2 yield� Other Toxic Gas by FT�IR
3 Meter Cube SmokeDensity Tester
CSD-S14, CSD-W14
IEC 61034-1&2
BS 6853
FESTEC’s 3 Meter Smoke Density Testeris the testing equipment measuring thesmoke generated when the cable or op-tical cable is placed horizontally and burnunder definite fire resource in the speci-fied condition (3m3 chamber required byIEC 61034).
Korea Electric Power Coporation(KEPCO) purchase standard (KS IEC605002�2): more than 60% of lightpenetration ratio
Single Burning ItemsSBI-606
EN 13823,BS
EN 13823
Single Burning Items measures heatrelease rate (FIGRA), smoke growthrate index (SMOGRA), oxygen con-sumption, CO and CO2 production,and mass loss rate per test meth-ods for European building materi-als.
� Average Heat Release Rate, Total HeatRelease Rate [THR (t)]
� Fire Growth Rate (FIGRA)� Fire Growth to side� RSPav (t)� Total Smoke Production Rate [TSP(t)]� Smoke Growth Rate [SMOGRA]� Total Smoke Production Rate [TSP600s]
Bunched Cable Ver-tical Flame Spread
TesterVFT-716
IEC 60332-3-10, KS C IEC60332-3-21~25
Bunched Cable Vertical FlameSpread Tester is a series conform-ing to IEC 60332�3�10, KS C IEC60332�3�21~25 (Category A~D)standards. The test measures theexpansion of vertical flame to theelectronically or optically verticalcable or wire using the standardignition source while supplying acertain amount of air to a chamberof a defined volume
Do not combustion from Burner morethan 2.5m.
III. Instrument List by Param
eterInstrument List by Class
No. Parameter Picture Product Name Standard Detail Description Evaluation Criteria
4 Ignitability
Spread of FlameTester
ISO 5658,ASTM E 1317,
IMOResolution A.
653
IMO is used to evaluate combustioncharacteristics of building materialsand ship materials and measuresspread rate of flame, flame for ig-nition by distances, CFE (CriticalFlux at Extinguishment) and totalheat release.
� Combustion Continued Heat� Average Combustion Continued Heat� Ignition Heat� During extinguishing, critical Heat flux� Total Heat Release� Maximum Heat Release
Cone CalorimeterLab' scale calorimeter :
Avg, 10~500 KW/㎡,CC
2006, ConeCalorimeter
ISO 5660,ASTM E1354,
NFPA 264,BS 476 pt15
Cone Calorimeter measures heatrelease rate, smoke release, ignitiontime, oxygen consumption, carbonmonoxide and carbon dioxide gen-eration and mass loss rate whentest sample is exposed to resourceof conical heater.
� Radition to Specimen� Combustion Gas Release Rate/ Orifice con-stance
� Ignition time and extinguishing time� Total Oxygen consumsion Rate/ Total Com-bustion Gas Production Rate
� Mass loss value and Mass loss Rate� Heat Release Rate / Effective burnin
Limited Oxygen IndexTester
ASTM D 2863, ISO4589�2,NES 714,
ASTM D2863,
ISO 4589-2,NES 714
FESTEC’s LOI(Limited Oxygen Indextester) measures minimum oxygen con-centration as necessary when specimencombustion. This equipment’s the oxy-gen analyser is adapted ParamagneticType which has a precise, long life, lesserror rate and high reliability.
More than 25% of Oxygen Index
Temperature OxygenIndex TesterASTM D 2863, ISO 4589�3, NES 715
ASTM D2863,
ISO 4589-3,NES 715
TOI(Temperature Oxygen Index Tester)measures temperature index of spec-imen by heated mixing gases on tem-perature up to 400℃ in theatmosphere oxygen concentration.According to ISO 4589�3, high temper-ature is best factor to assess com-bustibility of materials better thanOxygen Index.
Tests under the mixed gases tempera-ture condition to increase up to 400℃
4041/FIRE ENGINEERING & SCIENCE TECHNOLOGY
No. Parameter Picture Product Name Standard Detail Description Evaluation Criteria
4 Ignitability
UL 94�AVH ChamberPlastic CombustibilityTester, UL 94, ASTMD 5048, ASTM D3801, ASTM
D 4804, ASTM D4986, ISO
10351,ISO 1210, ISO9772,3, IEC 707
UL 94, ASTM D5048, ASTM D3801, ASTM D4804, ASTM D
4986, ISO 10351,ISO 1210, ISO 9772,3, IEC 707
UL 94 measures the combustionproperties (after flame, after glow)by burner (H�5025 UL tirrill burner)when test sample combusts inchamber's internal volume of 0.864㎥and is installed internal light to ob-serve the specimen's propertiesand has ventilating opening withemission fan to remove the com-bustion gas.
� After flame: Continued flame withoutfire sources
� After flame Time: Continued time toflame under standard
� After glow: Continued glow after applyheat sources and flame
� Aftrer glow time: Continued glow timeafter apply heat sources and flame
� Damaged length(Damaged length oftest specimen, mm)
� Ignited the cotton indicator by dripflaming
UL 1581Vertical Wire Flame
Chamber
UL 1581,VW-1
FT-1, FV-1,FT-
2, UL 2556
FESTEC’s VW�1(Vertical�Specimen)Flame Tester is applied standardflame to specimen as 5 times for 15sec. and it accordance with UL1581perfectly.
*Where any specimen shows more than 25percent of the indicator flag burned away orcharred (soot that can be removed with acloth or the fingers, and brown scorching,are to be ignored) after any of the five ap-plications of flame, the wire, cable, or cord isto be judged capable of conveying flamealong its length.
Fire Resistance WaterSpray Tester BS 6387
BS 6386 standard is belong to British,is a testing device that checks for thestandard level of current in the cable,and also checks the cable’s resistancefor heat and water of the cable.
Confirm any damage to the cable dueto high temperature and water or thecurrent status of approved power.
Bunched Cable Ver-tical Flame Spread
TesterVFT-716
IEC 60332-3,KS C IEC60332-3-21~25
Bunched Cable Vertical Flame SpreadTester is a series conforming to IEC60332�3�10, KS C IEC 60332�3�21~25(Category A~D) standards. The testmeasures the expansion of verticalflame to the electronically or opticallyvertical cable or wire using the stan-dard ignition source while supplying acertain amount of air to a chamber of adefined volume
Do not combustion from Burner morethan 2.5m.
III. Instrument List by Param
eterInstrument List by Class
No. Parameter Picture Product Name Standard Detail Description Evaluation Criteria
5 FlameSpread
Spread of FlameTester
ISO 5658,ASTM E 1317,IMO
Resolution A.653
IMO is used to evaluate combustioncharacteristics of building materialsand ship materials and measuresspread rate of flame, flame for ig-nition by distances, CFE (CriticalFlux at Extinguishment) and totalheat release.
� Combustion Continued Heat� Average Combustion Continued Heat� Ignition Heat� During extinguishing, critical heat flux� Total heat release� Maximum Heat release
Radiant Panel FlameSpread Tester
ASTM E 162, ASTMD3675
ASTM E 162,ASTM D3675
The Radiant Panel Flame Spread Testeris an equipment using gas ignited Radiantheat panel to test the surface com-bustibility of Building product (ASTM E162) and cellular plastics (ASTM E 3675),Radiant Panel Index (Is) is measured bythe flame radio�waves, Critical HeatFlux,(CHF) and Heat Release Rate(kW/㎡).
� Measure to Flame Spread, Critical HeatFlux (CHF) and Heat Release Rate (kW/㎡)
Flooring Radiant PanelTester
EN ISO9239-1
& 2, ASTM E648, ASTM
E970, NFPA253, KS FISO
9239-1 & 2
Flooring Radiant Panel Tester canmeasure critical heat flux (CHF) whichobserved flame spread length trans-formers Kw/㎡ using by heat stream-line velocity. And if specimen takesmore than 30 minute testing time, itcould be record a flame extinction timeand the farthest of flame spread, thentransforms it’s into CHF.
� Flame Spread Distance is changed to kW/㎡ to use Heat flux and measure CiticalHeat Flux (CHF).
� For the product to have test time morethan 30 min, flame extinugishing time andflame spread is recorded to far distanceand change to Critical Hear Flux (CHF)
� In case of required to smoke measure-ment, smoke density is measured bypenetration ratio of photometric system.
Single Burning ItemsMedium scale calorimeter :Avg, max 3 MW/㎡, SBI2006, prEN 13823, BS EN13823, Test Methods of In-ternal Finished Materials for
European Buildings
EN 13823,BS
EN 13823
Single Burning Items measures heatrelease rate (FIGRA), smoke growthrate index SMOGRA),oxygen con-sumption, CO and CO2 production,and mass loss rate per test meth-ods for European building materials.
� Average Heat Release Rate, Total HeatRelease Rate [THR (t)]
� Fire Growth Rate (FIGRA) Fire Growth to side� RSPav (t)� Total Smoke Production Rate [TSP(t)]� Smoke Growth Rate [SMOGRA]� Total Smoke Production Rate [TSP600s]
4243/FIRE ENGINEERING & SCIENCE TECHNOLOGY
No. Parameter Picture Product Name Standard Detail Description Evaluation Criteria
5 FlameSpread
Bunched Cable Verti-cal Flame Spread
TesterVFT-716
IEC 60332�3
Bunched Cable Vertical Flame SpreadTester is a series conforming to IEC60332�3�10, KS C IEC 60332�3�21~25(Category A~D) standards. The testmeasures the expansion of verticalflame to the electronically or opticallyvertical cable or wire using the stan-dard ignition source while supplying acertain amount of air to a chamber of adefined volume
Do not combustion from Burner morethan 2.5m.
6 Toxicity /Corrosivity
Cone CalorimeterLab' scale calorimeter :
Avg, 10~500 KW/㎡,CC
2006, ConeCalorimeter
ISO 5660,ASTM E1354,
NFPA 264,BS 476 pt15
Cone Calorimeter measures heatrelease rate, smoke release, ignitiontime, oxygen consumption, carbonmonoxide and carbon dioxide gen-eration and mass loss rate whentest sample is exposed to resourceof conical heater.
� Radition to Specimen� Combustion Gas release rate/ Orificeconstance
� Ignition time and extinguishing time� Total oxygen consumsion rate/ TotalCombustion Gas production rate
� Mass loss value and Mass loss rate� Heat release rate / Effective burnin
Naval EngineeringStandard 713 Toxic
ChamberNES 713
This tester measures the ToxicityIndex by ppm in Naval EngineeringStandard chamber when completecombustion occurs by burner.
When 100g of material is burned andthe material is diluted in the air ofchamber, concentration of each gener-ated gas is given by the equation.
Test on Gas Evolvedduring combustion ofelectric cables testerCable Halogen, PH &Conductivity Tester,HCT�717, IEC 60754�1,IEC 60754�2, KS C IEC
60754�1,KS C IEC 60754�2, KWS
409(5.12)
IEC 60754-1&2 , KS CIEC
60754-1&2,KWS 409
IEC 60754�1&2 Tester measures gasvolume of Halogen Acid (IEC 60754�1),pH concentration(PH Meter, Hydrogenions, IEC 60754�2), Conductivity(IEC60754�2) and etc from a wire (cable)by radiant heat in the Tube Furnace(IEC 60754�1: 800°c, IEC 60754�2: 950°c)Especially, FESTEC’s IEC 60754�1&2 isenable to test both IEC 60754�1 andIEC 60754�2 standards by one equip-ment and mode select function.
less than 0.5% of HCI gas production,more than PH 4.3, less than Conductivity10μs/mm
III. Instrument List by Param
eterInstrument List by Class
No. Parameter Picture Product Name Standard Detail Description Evaluation Criteria
7 Mass Loss
Smoke Box Smoke Density Tester,ASTM E 662, F 814, BS6401, ISO 5659, NES
711
ASTM E 662,BS 6401, ISO5659, NES 711
Smoke Box (Smoke Density Chamber)measures optical density of smoke gen-erated from test sample when test sampleof certain thickness is exposed to heatsource(2.5W/c㎡, 25㎾/㎡ using by E 662furnace) or fire in a chamber. This testmethod is increasingly used in interiormaterial of rolling stock, low power in-combustible cable and interior film, etc.
Fire Service Act. 20 (Criteria fire resist-ance material and performance of fireresistance) section 5: 400 of Maximumsmoke production
Cone CalorimeterLab' scale calorimeter :Avg, 10~500 KW/m2,
CC2006, ConeCalorimeter
ISO 5660,ASTM E1354,
NFPA 264,BS 476 pt15
Cone Calorimeter measures heatrelease rate, smoke release, ignitiontime, oxygen consumption, carbonmonoxide and carbon dioxide gen-eration and mass loss rate whentest sample is exposed to resourceof conical heater.
� Radition to Specimen� Combustion Gas release rate/ Orifice con-stance
� Ignition time and extinguishing time� Total oxygen consumsion rate/ Total Com-bustion Gas production rate
� Mass loss value and Mass loss rate� Heat release rate / Effective burnin
8 Fire Resist-ance
Building ConstructionFire ResistanceTester
ISO 834-1,ISO834-4~9,KS F 2275-1,KS F 2268-1,BS 476, BS EN1363,1364,1365, 1366 &1634-1, ASTME 119, ASTM E814, UL 10, UL263, UL1709,UL1479, UL2079, ISO3008, ISO3009
FESTEC’s Building ConstructionFire Resistance Tester measuresthe performance of constructionmaterial against standard fireconditions, and satisfies the generalrequirements, vertical history sec-tion material, vertical non�historysection material and the fireproofdoor’s fire proof testing. Thisequipment tests about the walls,doors, dampers, connections,through type sealing material, etc.such as the product of test for fireresistance.
After applying a certain amount of headwithin the fireproof door (ISO Curve) andmeasure the degree of twist (disposition)and any damages due to heat, andadditionally measure any flow of heattowards the exterior.
Fire ResistanceWater Spray Tester BS 6387
BS 6386 standard is belong to British,is a testing device that checks for thestandard level of current in the cable,and also checks the cable’s resist-ance for heat and water of the cable.
Confirm any damage to the cable dueto high temperature and water or thecurrent status of approved power.
4445/FIRE ENGINEERING & SCIENCE TECHNOLOGY
관련 산업 분야
IV. Test Parameters & Industry Sectors
장비명
열방출율Heat ReleaseRate
연기발생SmokeProduction
착화성Ignitability
화염전파FlameSpread
독성/부식성Toxity/Corrosivity
질량감소Mass Loss
내화Fire
Resistance
유럽 건축물EuropeanConstructionProducts
케이블ElectricCables
운송 수단Railway &
Transportaion
항공Aviation
플라스틱Plastics
건축 재료BuildingMaterial
운송물UN
Hazard
유류 제품PetroleumProducts
IEC 기준IEC
Standard
FTP 코드FTPCode
UL 기준UL
Standard
불연재료 난연성능 시험기
(ISO 1182:2002)● ● ● ●
연기밀도 시험기(ISO 5659-2:2006)
● ● ● ● ● ● ● ●
건축 부재(방화문 등)내화 성능 시험기, 수직가열로
(ISO 834-1: 1999)● ●
화염전파 시험기(ISO 5658-2:2006)
● ● ● ● ●
라지스케일칼로리미터(ISO 9705:1993) ● ● ● ● ● ●
룸코너테스터(ISO 9705:1993) ● ● ● ● ●
콘칼로리미터(ISO 5660-1:2002)
● ● ● ● ● ● ● ●
산소지수 시험기(ASTM D 2863,ISO 4589-2, NES
714)
● ● ● ●
온도지수 시험기(ASTM D 2863,ISO 4589-3,NES715)
● ● ●
플라스틱 연소성 시험기UL 94 AVH Chamber ● ● ● ●
측정 요소
IV. Test Parameters & Industry Sectors
Industry Sectors
InstrumentHeat ReleaseRate
SmokeProduction Ignitability
FlameSpread
Toxity/Corrosivity
Mass Loss
FireResistance
EuropeanConstructionProducts
ElectricCables
Railway &Transportaion Aviation Plastics
BuildingMaterial
UNHazard
PetroleumProducts
IECStandard
FTPCode
ULStandard
Non-Com-bustibility Tester(ISO 1182:2002)
● ● ● ●
Smoke Box(ISO5659-2: 2006) ● ● ● ● ● ● ● ●
Building Construc-tion Fire ResistanceTester(ISO 834-1:
1999)
● ●
Spread of FlameTester
(ISO 5658-2:2006)
● ● ● ● ●
Large ScaleCalorimeter(ISO 9705:1993)
● ● ● ● ● ●
Room CornerTetser(ISO9705:1993)
● ● ● ● ●
Cone Calorime-ter(ISO 5660-1:
2002)● ● ● ● ● ● ● ●
Limited Oxygen IndexTester (ASTM D2863, ISO 4589-2,
NES 714)
● ● ● ●
Temperature Oxy-gen Index Tester(ASTM D 2863, ISO4589-3, NES715)
● ● ●
UL 94 AVH Chamber ● ● ● ●
Test Parameters
Instrument List by Class
관련 산업 분야측정 요소 Industry SectorsTest Parameters
4647/FIRE ENGINEERING & SCIENCE TECHNOLOGY
InstrumentHeat ReleaseRate
SmokeProduction Ignitability
FlameSpread
Toxity/Corrosivity
Mass Loss
FireResistance
EuropeanConstructionProducts
ElectricCables
Railway &Transportaion Aviation Plastics
BuildingMaterial
UNHazard
PetroleumProducts
IECStandard
FTPCode
ULStandard
UL 1581 VerticalFlame Chamber ● ● ● ●
EN ISO 11925Single FlameSource Test
● ● ●
Radiant PanelFlame SpreadTester
(ASTM E 162,ASTM D 3675)
● ● ●
Flooring RadiantPanel Tester(ISO 9239-1)
● ● ● ●
3 Meter Cube SmokeDensity Tester
(IEC 61034, BS 6853)● ● ● ●
Naval EngineeringStandard 713 ToxicChamber (NES 713)
● ●
IEC 60754 - 1 & 2(Halogen, PH &ConductivityTester)
● ● ● ●
Single BurningItem (EN 13823) ● ● ● ● ●
Fire ResistanceWater Spray Tester
(BS 6387)● ● ● ●
관련 산업 분야측정 요소 Industry SectorsTest Parameters IV. Test Parameters & Industry SectorsInstrument List by Class
InstrumentHeat ReleaseRate
SmokeProduction Ignitability
FlameSpread
Toxity/Corrosivity
Mass Loss
FireResistance
EuropeanConstructionProducts
ElectricCables
Railway &Transportaion Aviation Plastics
BuildingMaterial
UNHazard
PetroleumProducts
IECStandard
FTPCode
ULStandard
Bunched Cable Ver-tical Flame SpreadTester (IEC 60332-3)
● ● ● ● ● ● ● ● ●
Glow Wire TestIEC 60695-2-10,
UL 746A● ●
Mouse Tester _Noxious GasTester byMouse
●
Vertical Furnace Criti-cal Heat Flux Tester_ KS F 2268, FTP Code 1
● ●
Thermal Character-istic Analyser _ ISO5660-1, KS F ISO
5660-1
●
Conical Heater 3Step TemperatureController _ ISO5660Optional Part 1
●
Time & PressureTester ●
Flame DurabilityTester
KS M 2010, ISO2592
● ●
Tag Closed Cup AutoFlash Point Tester
KS M 2010, ASTM D 56●
Fire ResistanceTester
IEC60331-11&21● ●
관련 산업 분야측정 요소 Industry SectorsTest Parameters
4849/FIRE ENGINEERING & SCIENCE TECHNOLOGY
InstrumentHeat ReleaseRate
SmokeProduction Ignitability
FlameSpread
Toxity/Corrosivity
Mass Loss
FireResistance
EuropeanConstructionProducts
ElectricCables
Railway &Transportaion Aviation Plastics
BuildingMaterial
UNHazard
PetroleumProducts
IECStandard
FTPCode
ULStandard
Fire MechanicalShock TesterIEC60331-12&31
● ●
EN50399 ●
Single VerticalFlame SpreadTester
IEC 60332-1● ● ●
NF X 70-100 ●
Solar Cell & RoofSpread of Flame &Burning Brand
Tester_ IEC61730-2
● ●
Erosion TrackingTester
IEC60587, ASTMD 2303
●
Hot Wire Coil Ig-nition TesterIEC 60695-2-20
●
Fire Resistance As-semblies TesterIEEE1202, IEEE383,
UL1685
●