RESIDENTIAL ROOFING www.metalcraftgroup.co.nz Architectural / Specification Enquiries Ph: 09 274 0408 Mobile: 027 603 1096 Email: [email protected] ThermoSpan EPS RREPS Metalcraft Insulated Panel Systems 00 / 25 COVER SHEET 01 / 25 ROOF RIDGE 02 / 25 ROOF RIDGE 2 03 / 25 SAWTOOTH RIDGE 04 / 25 SAWTOOTH EAVE 05 / 25 SAW TOOTH SOFFIT DETAIL 06 / 25 ROOF VALLEY 07 / 25 BARGE WITH PROFILED CLADDING 08 / 25 GUTTER DETAIL 09 / 25 CANTILEVER BARGE CAPPING DETAIL 10 / 25 PARAPET WITH TRANSVERSE APRON 11 / 25 TRANSVERSE APRON 12 / 25 PARALLEL APRON 13 / 25 MAX. 85mm DIAMETER PIPE PENETRATION 14 / 25 OVER 85mm DIAMETER PIPE PENETRATION 15 / 25 RESIDENTIAL STEP DETAIL 15A / 25 EXPANSION STEP DETAIL 16 / 25 CHIMNEY PENETRATION DETAIL 17 / 25 FASCIA AND BARGE FLASHING DIMENSIONS 18 / 25 3D RIDGE TO BARGE JUCTION 19 / 25 3D DUTCH GABLE 20 / 25 3D APRON 21 / 25 3D OVER 85mm DIAMETER PIPE PENETRATION 22 / 25 3D CHIMNEY PENETRATION 23 / 25 3D RIDGE/BARGE FLASHINGS 24 / 25 3D DUTCH GABLE FLASHINGS 25 / 25 PANEL PROFILE AND SIZE DETAIL LIST

S: 5 Metalcraft Roofing01 WIP01 BIM© 2013 Drawing …dvgdd8qyw67xs.cloudfront.net/1030/rreps_residential-roof-thermo... · pre-finished ridge cap 0.55 flashing stopends to roof cladding

Embed Size (px)

Citation preview

Page 1: S: 5 Metalcraft Roofing01 WIP01 BIM© 2013 Drawing …dvgdd8qyw67xs.cloudfront.net/1030/rreps_residential-roof-thermo... · pre-finished ridge cap 0.55 flashing stopends to roof cladding

RESIDENTIAL ROOFING

www.metalcraftgroup.co.nz

Architectural / Specification EnquiriesPh: 09 274 0408

Mobile: 027 603 1096Email: [email protected]

ThermoSpan EPS

RREPSMetalcraftInsulated Panel Systems

00 / 25 COVER SHEET01 / 25 ROOF RIDGE02 / 25 ROOF RIDGE 203 / 25 SAWTOOTH RIDGE04 / 25 SAWTOOTH EAVE05 / 25 SAW TOOTH SOFFIT DETAIL06 / 25 ROOF VALLEY07 / 25 BARGE WITH PROFILED CLADDING08 / 25 GUTTER DETAIL09 / 25 CANTILEVER BARGE CAPPING DETAIL10 / 25 PARAPET WITH TRANSVERSE APRON11 / 25 TRANSVERSE APRON12 / 25 PARALLEL APRON13 / 25 MAX. 85mm DIAMETER PIPE PENETRATION14 / 25 OVER 85mm DIAMETER PIPE PENETRATION15 / 25 RESIDENTIAL STEP DETAIL15A / 25 EXPANSION STEP DETAIL16 / 25 CHIMNEY PENETRATION DETAIL17 / 25 FASCIA AND BARGE FLASHING DIMENSIONS18 / 25 3D RIDGE TO BARGE JUCTION19 / 25 3D DUTCH GABLE20 / 25 3D APRON21 / 25 3D OVER 85mm DIAMETER PIPE PENETRATION22 / 25 3D CHIMNEY PENETRATION23 / 25 3D RIDGE/BARGE FLASHINGS24 / 25 3D DUTCH GABLE FLASHINGS25 / 25 PANEL PROFILE AND SIZE

DETAIL LIST

Page 2: S: 5 Metalcraft Roofing01 WIP01 BIM© 2013 Drawing …dvgdd8qyw67xs.cloudfront.net/1030/rreps_residential-roof-thermo... · pre-finished ridge cap 0.55 flashing stopends to roof cladding

PRE-FINISHED RIDGE CAP0.55 FLASHING

STOPENDS TO ROOF CLADDING

PURLIN

METALCRAFTTHERMOSPAN ROOFING

14G TEK SCREW WITH NEOPRENEWASHER 40mm MIN. EMBEDMENTIN EACH RIB

PROFILED EDGE DRESSEDOVER THERMOSPAN RIBS

TIMBER FRAMEBY OTHERS

0.55mm COLORSTEELFLASHING

DIMENSION VARIES DEPENDINGON PANEL THICKNESSES

5mm RIVETS

FOAM INFILL

5mm POP RIVETS OR PREFINISHEDSELF TAPPING SCREW WITHNEOPRENE WASHER

PROFILED FILLERSEALED TOP & BOTTOM

XX

BUTYL TAPE(OPTIONAL)

3° m

in.

5mm

GAP

SITUATION 1

1. LOW, MEDIUM, HIGH WIND ZONES,WHERE ROOF PITCH ≥ 10°

MIN. 130mm(EXCLUDDING ANY SOFT EDGE ORTURN-DOWN TO ROOFING)

SITUATION 2

1. ALL ROOF PITCHES IN VERY HIGHWIND ZONE2. LOW, MEDIUM, HIGH WIND ZONESWHERE ROOF PITCH ≤ 10°

MIN. 200mm(EXCLUDDING ANY SOFT EDGE ORTURN-DOWN TO ROOFING)

X

SITUATION 3

1. FOR ALL ROOF PITCHES INEXTRA HIGH WIND ZONES

CATEGORY A

1. NORMAL EXPOSURE2. ROOF PITCH >10°

MIN. 130mm

CATEGORY B

1. EXPOSED (HIGHER RISK) & WIND LOAD EXCEEDS 1.5 kPa.2. ROOF PITCH <10°

MIN. 200mmX

ALTERNATIVE SOLUTION AS PER MRM CODE OF PRACTICE

ACCEPTABLE SOLUTION AS PER E2/ASI

Reference

DISCLAIMER:All details are to be used for indicative purposes only and the designer should consult both the MRM code ofpractice version 2.2 /2012, E2 and all other relevant building codesDetails of the supporting mechanisms are indicative only. Compliance of the supporting mechanisms is theresponsibility of the designer.

RESIDENTIAL ROOFING

ScaleDate Sheet

ThermoSpan Residental

RRTSMetalcraftInsulated Panel Systems 1 : 5

ROOF RIDGE

01 / 2530.08.2016

Page 3: S: 5 Metalcraft Roofing01 WIP01 BIM© 2013 Drawing …dvgdd8qyw67xs.cloudfront.net/1030/rreps_residential-roof-thermo... · pre-finished ridge cap 0.55 flashing stopends to roof cladding

PRE-FINISHED RIDGE CAP0.55 FLASHING

STOPENDS TO ROOF CLADDING

METALCRAFTTHERMOSPAN ROOFING

14G TEK SCREW WITHNEOPRENE WASHER 40mm MIN.EMBEDMENT IN EACH RIB

PROFILED EDGE OVERTHERMOSPAN RIBS

TIMBER FRAME BY OTHERS

FOAM INFILL

5mm POP RIVET OR PRE-FINISHEDSELF-TAPPING TEK SCREW WITHNEOPRENE WASHER

PROFILED FILLER SEALEDTOP & BOTTOM

X X

3° m

in.

5mm

GAP

SITUATION 1

1. LOW, MEDIUM, HIGH WIND ZONES,WHERE ROOF PITCH ≥ 10°

MIN. 130mm(EXCLUDDING ANY SOFT EDGE ORTURN-DOWN TO ROOFING)

SITUATION 2

1. ALL ROOF PITCHES IN VERY HIGHWIND ZONE2. LOW, MEDIUM, HIGH WIND ZONESWHERE ROOF PITCH ≤ 10°

MIN. 200mm(EXCLUDDING ANY SOFT EDGE ORTURN-DOWN TO ROOFING)

X

SITUATION 3

1. FOR ALL ROOF PITCHES INEXTRA HIGH WIND ZONES

CATEGORY A

1. NORMAL EXPOSURE2. ROOF PITCH >10°

MIN. 130mm

CATEGORY B

1. EXPOSED (HIGHER RISK) & WIND LOAD EXCEEDS 1.5 kPa.2. ROOF PITCH <10°

MIN. 200mmX

ALTERNATIVE SOLUTION AS PER MRM CODE OF PRACTICE

ACCEPTABLE SOLUTION AS PER E2/ASI

Reference

DISCLAIMER:All details are to be used for indicative purposes only and the designer should consult both the MRM code ofpractice version 2.2 /2012, E2 and all other relevant building codesDetails of the supporting mechanisms are indicative only. Compliance of the supporting mechanisms is theresponsibility of the designer.

RESIDENTIAL ROOFING

ScaleDate Sheet

ThermoSpan Residental

RRTSMetalcraftInsulated Panel Systems 1 : 5

ROOF RIDGE 2

02 / 2530.08.2016

Page 4: S: 5 Metalcraft Roofing01 WIP01 BIM© 2013 Drawing …dvgdd8qyw67xs.cloudfront.net/1030/rreps_residential-roof-thermo... · pre-finished ridge cap 0.55 flashing stopends to roof cladding

PROFILED EDGE OVERTHERMOSPAN RIBS

STOPENDS TO PANEL ROOFING

TIMBER FRAMING BY OTHERS

WEATHERBOARDS ON CAVITY

PERMEABLE WALL UNDERLAY,SHOWN DASHED

5mm POP RIVET OR PRE-FINISHEDSELF-TAPPING TEK SCREW WITHNEOPRENE WASHER

METALCRAFT THERMOSPANROOFING

PRE-FINISHED SAWTOOTHRIDGE CAP 0.55 FLASHING

14G TEK SCREW WITHNEOPRENE WASHER 40mmMIN. EMBEDMENT IN EACH RIB

PRE-FINISHED SAWTOOTHSOFFIT FLASHING

X

5mm

GAP

FOAM INFILL

PRE-FINISHED POP RIVET BEDDEDIN SILICONE OR PRE-FINISHED 8gWAFER-TEK SCREW

BUTYL TAPE (OPTIONAL)

3° m

in.

SITUATION 1

1. LOW, MEDIUM, HIGH WIND ZONES,WHERE ROOF PITCH ≥ 10°

MIN. 130mm(EXCLUDDING ANY SOFT EDGE ORTURN-DOWN TO ROOFING)

SITUATION 2

1. ALL ROOF PITCHES IN VERY HIGHWIND ZONE2. LOW, MEDIUM, HIGH WIND ZONESWHERE ROOF PITCH ≤ 10°

MIN. 200mm(EXCLUDDING ANY SOFT EDGE ORTURN-DOWN TO ROOFING)

X

SITUATION 3

1. FOR ALL ROOF PITCHES INEXTRA HIGH WIND ZONES

CATEGORY A

1. NORMAL EXPOSURE2. ROOF PITCH >10°

MIN. 130mm

CATEGORY B

1. EXPOSED (HIGHER RISK) & WIND LOAD EXCEEDS 1.5 kPa.2. ROOF PITCH <10°

MIN. 200mmX

ALTERNATIVE SOLUTION AS PER MRM CODE OF PRACTICE

ACCEPTABLE SOLUTION AS PER E2/ASI

Reference

DISCLAIMER:All details are to be used for indicative purposes only and the designer should consult both the MRM code ofpractice version 2.2 /2012, E2 and all other relevant building codesDetails of the supporting mechanisms are indicative only. Compliance of the supporting mechanisms is theresponsibility of the designer.

RESIDENTIAL ROOFING

ScaleDate Sheet

ThermoSpan Residental

RRTSMetalcraftInsulated Panel Systems 1 : 5

SAWTOOTH RIDGE

03 / 2530.08.2016

Page 5: S: 5 Metalcraft Roofing01 WIP01 BIM© 2013 Drawing …dvgdd8qyw67xs.cloudfront.net/1030/rreps_residential-roof-thermo... · pre-finished ridge cap 0.55 flashing stopends to roof cladding

TIMBER/FIBRE CEMENTSOFFIT

METALCRAFT THERMOSPANROOFING

PRE-FINISHED SAWTOOTHRIDGE CAP FLASHING

STOPENDS TO ROOFCLADDING

PROFILED EDGE OVERTHERMOSPAN RIBS

5mm POP RIVET OR PRE-FINISHEDSELF-TAPPING TEK SCREW WITHNEOPRENE WASHER

X

5mm

GAP

BUTYL TAPE (OPTIONAL)

PRE-FINISHED SELFTAPPING TEK SCREWWITH NEOPRENE WASHER

3° m

in.

SITUATION 1

1. LOW, MEDIUM, HIGH WIND ZONES,WHERE ROOF PITCH ≥ 10°

MIN. 130mm(EXCLUDDING ANY SOFT EDGE ORTURN-DOWN TO ROOFING)

SITUATION 2

1. ALL ROOF PITCHES IN VERY HIGHWIND ZONE2. LOW, MEDIUM, HIGH WIND ZONESWHERE ROOF PITCH ≤ 10°

MIN. 200mm(EXCLUDDING ANY SOFT EDGE ORTURN-DOWN TO ROOFING)

X

SITUATION 3

1. FOR ALL ROOF PITCHES INEXTRA HIGH WIND ZONES

CATEGORY A

1. NORMAL EXPOSURE2. ROOF PITCH >10°

MIN. 130mm

CATEGORY B

1. EXPOSED (HIGHER RISK) & WIND LOAD EXCEEDS 1.5 kPa.2. ROOF PITCH <10°

MIN. 200mmX

ALTERNATIVE SOLUTION AS PER MRM CODE OF PRACTICE

ACCEPTABLE SOLUTION AS PER E2/ASI

Reference

DISCLAIMER:All details are to be used for indicative purposes only and the designer should consult both the MRM code ofpractice version 2.2 /2012, E2 and all other relevant building codesDetails of the supporting mechanisms are indicative only. Compliance of the supporting mechanisms is theresponsibility of the designer.

RESIDENTIAL ROOFING

ScaleDate Sheet

ThermoSpan Residental

RRTSMetalcraftInsulated Panel Systems 1 : 5

SAWTOOTH EAVE

04 / 2530.08.2016

Page 6: S: 5 Metalcraft Roofing01 WIP01 BIM© 2013 Drawing …dvgdd8qyw67xs.cloudfront.net/1030/rreps_residential-roof-thermo... · pre-finished ridge cap 0.55 flashing stopends to roof cladding

METALCRAFT THERMOSPANROOFING

TIMBER FRAMING BY OTHERS

THERMOSPAN HEAD BARGE 0.55FLASHING

4.5mm SOFFIT BOARD

14G TEK SCREW WITHNEOPRENE WASHER 40mm MIN.EMBEDMENT IN EACH RIB

5mm POP RIVET OR PRE-FINISHEDSELF-TAPPING TEK SCREW WITHNEOPRENE WASHER

0.55 FLASHING OR 50x50 ANGLE

WEATHERBOARD

FOAM INFILL

STOPEND TO ROOF CLADDING

PERMEABLE WALL UNDERLAY,SHOWN DASHED

THERMAL CUT STEEL SKIN

X

5mm

GAP

BUTYL TAPE OPTIONAL

PRE-FINISHED SELF TAPPING TEKSCREW WITH NEOPRENEWASHER

3° min.

SITUATION 1

1. LOW, MEDIUM, HIGH WIND ZONES,WHERE ROOF PITCH ≥ 10°

MIN. 130mm(EXCLUDDING ANY SOFT EDGE ORTURN-DOWN TO ROOFING)

SITUATION 2

1. ALL ROOF PITCHES IN VERY HIGHWIND ZONE2. LOW, MEDIUM, HIGH WIND ZONESWHERE ROOF PITCH ≤ 10°

MIN. 200mm(EXCLUDDING ANY SOFT EDGE ORTURN-DOWN TO ROOFING)

X

SITUATION 3

1. FOR ALL ROOF PITCHES INEXTRA HIGH WIND ZONES

CATEGORY A

1. NORMAL EXPOSURE2. ROOF PITCH >10°

MIN. 130mm

CATEGORY B

1. EXPOSED (HIGHER RISK) & WIND LOAD EXCEEDS 1.5 kPa.2. ROOF PITCH <10°

MIN. 200mmX

ALTERNATIVE SOLUTION AS PER MRM CODE OF PRACTICE

ACCEPTABLE SOLUTION AS PER E2/ASI

Reference

DISCLAIMER:All details are to be used for indicative purposes only and the designer should consult both the MRM code ofpractice version 2.2 /2012, E2 and all other relevant building codesDetails of the supporting mechanisms are indicative only. Compliance of the supporting mechanisms is theresponsibility of the designer.

RESIDENTIAL ROOFING

ScaleDate Sheet

ThermoSpan Residental

RRTSMetalcraftInsulated Panel Systems 1 : 5

SAW TOOTH SOFFIT DETAIL

05 / 2530.08.2016

Page 7: S: 5 Metalcraft Roofing01 WIP01 BIM© 2013 Drawing …dvgdd8qyw67xs.cloudfront.net/1030/rreps_residential-roof-thermo... · pre-finished ridge cap 0.55 flashing stopends to roof cladding

TIMBER BEAMSTRUCTURE BY OTHERS

PURLIN

METALCRAFT THERMOSPANROOFING

14G TEK SCREW WITHNEOPRENE WASHER 40mmMIN. EMBEDMENT IN EACH RIB

PREFINISHED 0.55 VALLEY GUTTER

80mm MIN

50m

m M

IN

MIN

. 20mm

80mm MIN

B: CLEARANCE BETWEEN ROOFING

250mm MIN

SITUATION 1

MAX. CATCHMENT 25m²MIN. ROOF PITCH 8°

MIN. 250mm

MIN. 50mm

MIN. 80mm

SITUATION 2

MAX. CATCHMENT 16m²MIN. ROOF PITCH 12.5°

160mm - 249mm

MIN. 40mm

MIN. 60mm

A

B

C

ACCEPTABLE SOLUTION AS PER E2/ASI

* ROOF PITCH FOR VALLEYS AS PER E2.

Reference

DISCLAIMER:All details are to be used for indicative purposes only and the designer should consult both the MRM code ofpractice version 2.2 /2012, E2 and all other relevant building codesDetails of the supporting mechanisms are indicative only. Compliance of the supporting mechanisms is theresponsibility of the designer.

RESIDENTIAL ROOFING

ScaleDate Sheet

ThermoSpan Residental

RRTSMetalcraftInsulated Panel Systems As indicated

ROOF VALLEY

06 / 2530.08.2016

Page 8: S: 5 Metalcraft Roofing01 WIP01 BIM© 2013 Drawing …dvgdd8qyw67xs.cloudfront.net/1030/rreps_residential-roof-thermo... · pre-finished ridge cap 0.55 flashing stopends to roof cladding

PRE-FINISHED 0.55BARGE FLASHING

METALCRAFT THERMOSPANROOFING

WEATHERBOARDS ONCAVITY

PERMEABLE WALLUNDERLAY, SHOWN DASHED

TIMBER FRAMING BYOTHERS

14G TEK SCREW WITHNEOPRENE WASHER 40mmMIN. EMBEDMENT

Y

5mm RIVETS @ 250CRS.

Z PROFILE (NOT REQUIREDWHEN OVER 2 RIBS)

THERMAL CUT STEEL SKIN

Z

SITUATION 1

1. LOW, MEDIUM, HIGH WIND ZONES,WHERE ROOF PITCH ≥ 10°

AT LEAST TWO CRESTS

MIN. 50mm

SITUATION 2

1. VERY HIGH WIND ZONE2. LOW, MEDIUM & HIGH WINDZONES WHERE ROOF PITCH ≤ 10°AT LEAST TWO CRESTS

MIN. 70mm

Y

Z

SITUATION 3

1.ALL ROOF PITCHES IN EXTRAHIGH WIND ZONE

AT LEAST TWO CRESTS

MIN. 90mm

CATEGORY A

1. NORMAL EXPOSURE2. ROOF PITCH >10°

ONE RIB (TRAPEZOIDAL & TRAY)2 CORRUGATIONS

MIN. 50mm (VERTICALLY DOWN FACE - SMOOTH)MIN. 75mm (VERTICALLY DOWN FACE - PROFILED)

CATEGORY B

1. EXPOSED (HIGHER RISK) & WIND LOAD EXCEEDS 1.5 kPa.2. ROOF PITCH <10°

ONE RIB, TWO RIBS (<20mm) (TRAPEZOIDAL & TRAY)3 CORRUGATIONS

MIN. 75mm (VERTICALLY DOWN FACE - SMOOTH)MIN. 100mm (VERTICALLY DOWN FACE - PROFILED)

Y

Z

ALTERNATIVE SOLUTION AS PER MRM CODE OF PRACTICE

ACCEPTABLE SOLUTION AS PER E2/ASI

Reference

DISCLAIMER:All details are to be used for indicative purposes only and the designer should consult both the MRM code ofpractice version 2.2 /2012, E2 and all other relevant building codesDetails of the supporting mechanisms are indicative only. Compliance of the supporting mechanisms is theresponsibility of the designer.

RESIDENTIAL ROOFING

ScaleDate Sheet

ThermoSpan Residental

RRTSMetalcraftInsulated Panel Systems 1 : 5

BARGE WITH PROFILED CLADDING

07 / 2530.08.2016

Page 9: S: 5 Metalcraft Roofing01 WIP01 BIM© 2013 Drawing …dvgdd8qyw67xs.cloudfront.net/1030/rreps_residential-roof-thermo... · pre-finished ridge cap 0.55 flashing stopends to roof cladding

WEATHERBOARD

125x125x75 BOX GUTTER

FIBRE CEMENT SOFFIT LINING

TIMBER FRAMING BYOTHERS

METALCRAFTTHERMOSPAN ROOING

TIMBER PACKER

PERMEABLE WALLUNDERLAY, SHOWN DASHED

THERMOSPAN FASCIAFLASHING

0.55 FLASHING OR 50x50ANGLE

5mm RIVETS @ 250CRS.

14G TEK SCREW WITHNEOPRENE WASHER 40mm MIN.EMBEDMENT IN EACH RIDGE

PRE-FINISHED SELF-TAPPINGTEK SCREW WITH NEOPRENEWASHER

3° m

in.

75mm MIN

Reference

DISCLAIMER:All details are to be used for indicative purposes only and the designer should consult both the MRM code ofpractice version 2.2 /2012, E2 and all other relevant building codesDetails of the supporting mechanisms are indicative only. Compliance of the supporting mechanisms is theresponsibility of the designer.

RESIDENTIAL ROOFING

ScaleDate Sheet

ThermoSpan Residental

RRTSMetalcraftInsulated Panel Systems 1 : 5

GUTTER DETAIL

08 / 2530.08.2016

Page 10: S: 5 Metalcraft Roofing01 WIP01 BIM© 2013 Drawing …dvgdd8qyw67xs.cloudfront.net/1030/rreps_residential-roof-thermo... · pre-finished ridge cap 0.55 flashing stopends to roof cladding

METALCRAFT THERMOSPAN ROOFING

PERMEABLE WALL UNDERLAY,SHOWN DASHED

14G TEK SCREW WITH NEOPRENEWASHER 40mm MIN. EMBEDMENT INEACH RIB

WEATHERBOARDS ON CAVITY

TIMBER FRAME BY OTHERS0.55 FLASHING OR 50x50 ANGLE

THERMOSPAN HEAD 0.55 BARGEFLASHING

THERMAL CUT STEEL SKIN

0.55 FLASHING OR 50x50 ANGLE14G SELF TAPPING TEK SCREW WITHNEOPRENE WASHER

0.55 Z PROFILE FLASHING (NOTREQUIRED WHEN SPANNING 2 RIBS)

X

BUTYL TAPE (OPTIONAL)

SITUATION 1

1. LOW, MEDIUM, HIGH WIND ZONES,WHERE ROOF PITCH ≥ 10°

MIN. 130mm(EXCLUDDING ANY SOFT EDGE ORTURN-DOWN TO ROOFING)

SITUATION 2

1. ALL ROOF PITCHES IN VERY HIGHWIND ZONE2. LOW, MEDIUM, HIGH WIND ZONESWHERE ROOF PITCH ≤ 10°

MIN. 200mm(EXCLUDDING ANY SOFT EDGE ORTURN-DOWN TO ROOFING)

X

SITUATION 3

1. FOR ALL ROOF PITCHES INEXTRA HIGH WIND ZONES

CATEGORY A

1. NORMAL EXPOSURE2. ROOF PITCH >10°

MIN. 130mm

CATEGORY B

1. EXPOSED (HIGHER RISK) & WIND LOAD EXCEEDS 1.5 kPa.2. ROOF PITCH <10°

MIN. 200mmX

ALTERNATIVE SOLUTION AS PER MRM CODE OF PRACTICE

ACCEPTABLE SOLUTION AS PER E2/ASI

Reference

DISCLAIMER:All details are to be used for indicative purposes only and the designer should consult both the MRM code ofpractice version 2.2 /2012, E2 and all other relevant building codesDetails of the supporting mechanisms are indicative only. Compliance of the supporting mechanisms is theresponsibility of the designer.

RESIDENTIAL ROOFING

- BUILDING PAPER IS THE COMMON GENERIC NAME FOR PERMEABLEROOF AND WALL UNDERLAYS. PLEASE REFER TO NZBC E2/AS1 ANDMRM CODE OF PRACTICE VERSION 2.2 /2012.

ScaleDate Sheet

ThermoSpan Residental

RRTSMetalcraftInsulated Panel Systems 1 : 5

CANTILEVER BARGE CAPPING DETAIL

09 / 2530.08.2016

Page 11: S: 5 Metalcraft Roofing01 WIP01 BIM© 2013 Drawing …dvgdd8qyw67xs.cloudfront.net/1030/rreps_residential-roof-thermo... · pre-finished ridge cap 0.55 flashing stopends to roof cladding

SELF TAPPING TEK SCREW WITH NEOPRENEWASHER

BARGE BOARD

WEATHERBOARDS ON CAVITY

PERMEABLE WALL UNDERLAY,SHOWN DASHED

PRE-FINISHED 0.55 PARAPET CAPFLASHING

TIMBER PACKER

PERMEABLE WALL UNDERLAY TOPROVIDE SEPARATION OF METALCAPPING AND TIMBER, SHOWN DASHED

FOAM FILLWALL FRAMING

ALUM. ANGLE ENGINEERED BY OTHERS

PRE-FINISHED APRON FLASHING

TIMBER NOG FOR FIXING APRON FLASHING

CONTINUOUS TIMBER PACKING

STST OR GALV. FLAT HEAD NAIL FOR FLASHING

PRE-FINISHED SELF TAPPING WAFER-TEK SCREW WITH NEOPRENE WASHER

STOPENDS TO ROOF CLADDING

5mm POP RIVET OR PRE-FINISHED SELF-TAPPING TEK SCREW WITH NEOPRENE WASHER

Z

NG

L

3° m

in.

SITUATION 1

1. LOW, MEDIUM, HIGH WIND ZONES,WHERE ROOF PITCH ≥ 10°

MIN. 35mm

MIN. 75mm

MIN. 130mm(EXCLUDING ANY SOFT EDGE ORTURN-DOWN TO ROOFING)

MIN. 50mm

SITUATION 2

1. ALL ROOF PITCHES IN VERY HIGHWIND ZONE2. LOW, MEDIUM, & HIGH WINDZONES WHERE ROOF PITCH ≤ 10°

MIN. 35mm

MIN. 75mm

MIN. 200mm(EXCLUDING ANY SOFT EDGE ORTURN-DOWN TO ROOFING)

MIN. 70mm

G

N

L

Z

SITUATION 3

1. ALL ROOF PITCHES IN EXTRAHIGH WIND ZONE

MIN. 35mm

MIN. 75mm

MIN. 200mm(EXCLUDING ANY SOFT EDGE ORTURN-DOWN TO ROOFING)

MIN. 90mm

CATEGORY A

1. NORMAL EXPOSURE2. ROOF PITCH >10°

25mm

MIN. 50mm + HEM OR 75mm(VERTICALLY UP FACE - SMOOTH)MIN. 75mm + HEM OR 100mm(VERTICALLY UP FACE - PROFILED)

MIN. 150mm

MIN. 50mm (VERTICALLY DOWN FACE - SMOOTH)MIN. 75mm (VERTICALLY DOWN FACE - PROFILED)

CATEGORY B

1. EXPOSED (HIGHER RISK) & WIND LOAD EXCEEDS 1.5 kPa.2. ROOF PITCH <10°

25mm

MIN. 75mm + HEM OR 100mm(VERTICALLY UP FACE - SMOOTH)MIN. 100mm + HEM OR 125mm(VERTICALLY UP FACE - PROFILED)

MIN. 200mm

MIN. 75mm (VERTICALLY DOWN FACE - SMOOTH)MIN. 100mm(VERTICALLY DOWN FACE - PROFILED)

G

N

L

Z

ALTERNATIVE SOLUTION AS PER MRM CODE OF PRACTICE

ACCEPTABLE SOLUTION AS PER E2/ASI

Reference

DISCLAIMER:All details are to be used for indicative purposes only and the designer should consult both the MRM code ofpractice version 2.2 /2012, E2 and all other relevant building codesDetails of the supporting mechanisms are indicative only. Compliance of the supporting mechanisms is theresponsibility of the designer.

RESIDENTIAL ROOFING

ScaleDate Sheet

ThermoSpan Residental

RRTSMetalcraftInsulated Panel Systems 1 : 5

PARAPET WITH TRANSVERSE APRON

10 / 2530.08.2016

Page 12: S: 5 Metalcraft Roofing01 WIP01 BIM© 2013 Drawing …dvgdd8qyw67xs.cloudfront.net/1030/rreps_residential-roof-thermo... · pre-finished ridge cap 0.55 flashing stopends to roof cladding

STOPENDS TO ROOF CLADDING

FOAM FILL

WALL FRAMING

PVC CAVITY CLOSER

WEATHERBOARDS ON CAVITY

NOG FOR FIXING APRON FLASHING

STST OR GALV. FLAT HEAD NAIL FORFLASHING

5mm POP RIVET OR PRE-FINISHED SELF-TAPPING TEK SCREW WITH NEOPRENEWASHER

METALCRAFT THERMOSPANROOFINGPRE-FINISHED 0.55 APRON FLASHING

PERMEABLE WALL UNDERLAY OVERFLASHING SHOWN DASHED

PERMEABLE WALL UNDERLAY,SHOWN DASHED

50x50x5mm ALUMINIUM ANGLEENGINEERED BY OTHERS

PREFINISHED SELF-TAPPING TEK SCREWSWITH NEOPRENE WASHER

FOAM FILL

3° m

in.

NG L

SITUATION 1

1. LOW, MEDIUM, HIGH WIND ZONES,WHERE ROOF PITCH ≥ 10°

MIN. 35mm

MIN. 75mm

MIN. 130mm(EXCLUDING ANY SOFT EDGE ORTURN-DOWN TO ROOFING)

SITUATION 2

1. ALL ROOF PITCHES IN VERY HIGHWIND ZONES2. LOW, MEDIUM, AND HIGH WINDZONES WHERE ROOF PITCH ≤ 10°

MIN. 35mm

MIN. 75mm

MIN. 200mm(EXCLUDING ANY SOFT EDGE ORTURN-DOWN TO ROOFING)

G

N

L

SITUATION 3

1. ALL ROOF PITCHES IN EXTRA HIGHWIND ZONE

MIN. 35mm

MIN. 200mm(EXCLUDING ANY SOFT EDGE OR TURN-DOWN TO ROOFING)

CATEGORY A

1. NORMAL EXPOSURE2. ROOF PITCH >10°

25mm

MIN. 50mm + HEM OR 75mm(VERTICALLY UP FACE - SMOOTH)MIN. 75mm + HEM OR 100mm(VERTICALLY UP FACE - PROFILED)

MIN. 150mm

CATEGORY B

1. EXPOSED (HIGHER RISK) & WIND LOAD EXCEEDS 1.5 kPa.2. ROOF PITCH <10°

25mm

MIN. 75mm + HEM OR 100mm(VERTICALLY UP FACE - SMOOTH)MIN. 100mm + HEM OR 125mm(VERTICALLY UP FACE - PROFILED)

MIN. 200mm

G

N

L

ALTERNATIVE SOLUTION AS PER MRM CODE OF PRACTICE

ACCEPTABLE SOLUTION AS PER E2/ASI

Reference

DISCLAIMER:All details are to be used for indicative purposes only and the designer should consult both the MRM code ofpractice version 2.2 /2012, E2 and all other relevant building codesDetails of the supporting mechanisms are indicative only. Compliance of the supporting mechanisms is theresponsibility of the designer.

RESIDENTIAL ROOFING

ScaleDate Sheet

ThermoSpan Residental

RRTSMetalcraftInsulated Panel Systems 1 : 5

TRANSVERSE APRON

11 / 2530.08.2016

Page 13: S: 5 Metalcraft Roofing01 WIP01 BIM© 2013 Drawing …dvgdd8qyw67xs.cloudfront.net/1030/rreps_residential-roof-thermo... · pre-finished ridge cap 0.55 flashing stopends to roof cladding

PRE-FINISHED 0.55 APRONFLASHING

WEATHERBOARDS ON CAVITY

PERMEABLE WALL UNDERLAYOVER FLASHING, SHOWN DASHED

STST OR GALV. FLAT HEADNAIL FOR FIXING

NOG FOR FIXING APRONFLASHING

PVC CAVITY CLOSER

METALCRAFT THERMOSPANROOFING

5mm POP RIVET OR PRE-FINISHED SELF-TAPPING TEK SCREW WITH NEOPRENEWASHER

WALL FRAMING

PERMEABLE WALL UNDERLAY,SHOWN DASHED

FOAM FILL

50x50x5mm ALUMINIUM ANGLEENGINEERED BY OTHERS

GN

5mm

GAP

PRE-FILLED SELF-TAPPING TEKSCREW WITH NEOPRENE WASHER

M

SITUATION 1

1. LOW, MEDIUM, HIGH WIND ZONES,WHERE ROOF PITCH ≥ 10°

MIN. 35mm

MIN. 75mm

AT LEAST TWO CRESTS

SITUATION 2

1. ALL ROOF PITCHES INVERY HIGHWIND ZONE2. LOW, MEDIUM, AND HIGH WINDZONES WHERE ROOF PITCH ≤ 10°

MIN. 35mm

MIN. 75mm

AT LEAST TWO CRESTS

G

N

M

SITUATION 3

1. ALL ROOF PITCHES IN EXTRAHIGH WIND ZONE

MIN. 35mm

MIN. 75mm

AT LEAST TWO CRESTS

CATEGORY A

1. NORMAL EXPOSURE2. ROOF PITCH >10°

25mm

MIN. 50mm + HEM OR 75mm(VERTICALLY UP FACE - SMOOTH)MIN. 75mm + HEM OR 100mm(VERTICALLY UP FACE - PROFILED)

ONE RIB (TRAPEZOIDAL & TRAY)2 CORRUGATIONS (CORRUGATE)

CATEGORY B

1. EXPOSED (HIGHER RISK) & WIND LOAD EXCEEDS 1.5 kPa.2. ROOF PITCH <10°

25mm

MIN. 75mm + HEM OR 100mm(VERTICALLY UP FACE - SMOOTH)MIN. 100mm + HEM OR 125mm(VERTICALLY UP FACE - PROFILED)

TWO RIBS (<20mm) (TRAPEZOIDAL & TRAY)3 CORRUGATIONS (CORRUGATE)

G

N

M

ALTERNATIVE SOLUTION AS PER MRM CODE OF PRACTICE

ACCEPTABLE SOLUTION AS PER E2/ASI

Reference

DISCLAIMER:All details are to be used for indicative purposes only and the designer should consult both the MRM code ofpractice version 2.2 /2012, E2 and all other relevant building codesDetails of the supporting mechanisms are indicative only. Compliance of the supporting mechanisms is theresponsibility of the designer.

RESIDENTIAL ROOFING

ScaleDate Sheet

ThermoSpan Residental

RRTSMetalcraftInsulated Panel Systems 1 : 5

PARALLEL APRON

12 / 2530.08.2016

Page 14: S: 5 Metalcraft Roofing01 WIP01 BIM© 2013 Drawing …dvgdd8qyw67xs.cloudfront.net/1030/rreps_residential-roof-thermo... · pre-finished ridge cap 0.55 flashing stopends to roof cladding

METALCRAFT THERMOSPAN ROOFING

PIPE (PIPEDIAMETER MIX.85mm)

EPDM FLEXIBLE CONE SLEEVE

MALLEABLE FLANGE, SCREW ORRIVET FIXED, AND SEALED TOPANEL PROFILE. FIT NEOPRENEWASHERS TO ALL SCREW FIXINGS.FITTED ON 45° ANGLE IN PLAN.REFER TO MRM CODE OF PRACTICEVERSION 2 2/2012.

TIMBER PURLIN

14G TEK SCREW WITH NEOPRENEWASHER 40mm MIN. EMBEDMENTIN EACH RIB

90mm FRAMING BY OTHERS

FOAM INFILL

0.55mm FLASHING

3° min.

Reference

DISCLAIMER:All details are to be used for indicative purposes only and the designer should consult both the MRM code ofpractice version 2.2 /2012, E2 and all other relevant building codesDetails of the supporting mechanisms are indicative only. Compliance of the supporting mechanisms is theresponsibility of the designer.

RESIDENTIAL ROOFING

ScaleDate Sheet

ThermoSpan Residental

RRTSMetalcraftInsulated Panel Systems 1 : 5

MAX. 85mm DIAMETER PIPE PENETRATION

13 / 2530.08.2016

Page 15: S: 5 Metalcraft Roofing01 WIP01 BIM© 2013 Drawing …dvgdd8qyw67xs.cloudfront.net/1030/rreps_residential-roof-thermo... · pre-finished ridge cap 0.55 flashing stopends to roof cladding

PRE-FINISHED SOAKERFLASHING UNDER PRE-FINISHEDROOF RIDGE CAP FLASHING

PIPE (PIPE DIAMETER OVER85mm AND MAX. 500mm)

EPDM FLEXIBLE CONE SLEEVE

METALCRAFT THERMOSPANROOFING

MALLEABLE FLANGE, SCREW ORRIVET FIXED, AND SEALED TO ROOFINGPROFILE. FIT NEOPRENE WASHERS TOALL SCREW FIXINGS. FITTED ON 45°ANGLE IN PLAN. REFER TO MRM CODEOF PRACTICE VERSION 2 2/2012. PRE-FINISHED SOAKER FLASHING

WITH PRE-FINISHED POP RIVETBEDDED IN SILICONE OR PRE-FINISHED 8g WAFER-TEK SCREW

METALCRAFT THERMOSPANROOFING

PRE-FINISHEDROOF RIDGECAP FLASHING

PRE-FINISHED SELF TAPPING TEK SCREWWITH NEOPRENE WASHER

EPDM FLEXIBLE CONE SLEEVE

TIMBER FRAMING BY OTHERS

X

M

FOAM INFILL

0.55mm FLASHING

PURLIN

L

5mm

GAP

REFER TO SHEET NO. 11/25 TRANSVERSE APRON

REFER TO SHEET NO. 12/25 PARALLEL APRON

REFER TO SHEET NO. 01/25 ROOF RIDGE

L

M

X

Reference

DISCLAIMER:All details are to be used for indicative purposes only and the designer should consult both the MRM code ofpractice version 2.2 /2012, E2 and all other relevant building codesDetails of the supporting mechanisms are indicative only. Compliance of the supporting mechanisms is theresponsibility of the designer.

RESIDENTIAL ROOFING

ScaleDate Sheet

ThermoSpan Residental

RRTSMetalcraftInsulated Panel Systems 1 : 5

OVER 85mm DIAMETER PIPE PENETRATION

14 / 2530.08.2016

Page 16: S: 5 Metalcraft Roofing01 WIP01 BIM© 2013 Drawing …dvgdd8qyw67xs.cloudfront.net/1030/rreps_residential-roof-thermo... · pre-finished ridge cap 0.55 flashing stopends to roof cladding

METALCRAFT THERMOSPAN ROOFING

14g TEK SCREW WITH NEOPRENE WASHERAT EACH RIB WITH 40mm MIN. EMBEDMENT

TIMBER FRAMING BY OTHERS

100

0.55mm BMT COLORSTEEL ANGLE

PRE-FINISHED 0.55BMTSTEPPED COLORSTEELFLASHING

PROFILLED FOAM CLOURESTRIP SEALED TOP &BOTTOM

5mm POP RIVET OR PRE-FINISHED SELF-TAPPINGTEK SCREW WITHNEOPRENE WASHER

3° m

in.

5mm

GAP

TURN UP PAN TO FULLRIB HEIGHT(SPECIAL TOOLAVAILABLE)

PACKER TO SUIT ROOFANGLE

X

SITUATION 1

1. LOW, MEDIUM, HIGH WIND ZONES,WHERE ROOF PITCH ≥ 10°

MIN. 130mm(EXCLUDDING ANY SOFT EDGE ORTURN-DOWN TO ROOFING)

SITUATION 2

1. ALL ROOF PITCHES IN VERY HIGHWIND ZONE2. LOW, MEDIUM, HIGH WIND ZONESWHERE ROOF PITCH ≤ 10°

MIN. 200mm(EXCLUDDING ANY SOFT EDGE ORTURN-DOWN TO ROOFING)

X

SITUATION 3

1. FOR ALL ROOF PITCHES INEXTRA HIGH WIND ZONES

CATEGORY A

1. NORMAL EXPOSURE2. ROOF PITCH >10°

MIN. 130mm

CATEGORY B

1. EXPOSED (HIGHER RISK) & WIND LOAD EXCEEDS 1.5 kPa.2. ROOF PITCH <10°

MIN. 200mmX

ALTERNATIVE SOLUTION AS PER MRM CODE OF PRACTICE

ACCEPTABLE SOLUTION AS PER E2/ASI

Reference

DISCLAIMER:All details are to be used for indicative purposes only and the designer should consult both the MRM code ofpractice version 2.2 /2012, E2 and all other relevant building codesDetails of the supporting mechanisms are indicative only. Compliance of the supporting mechanisms is theresponsibility of the designer.

RESIDENTIAL ROOFING

ScaleDate Sheet

ThermoSpan Residental

RRTSMetalcraftInsulated Panel Systems 1 : 5

RESIDENTIAL STEP DETAIL

15 / 2530.08.2016

Page 17: S: 5 Metalcraft Roofing01 WIP01 BIM© 2013 Drawing …dvgdd8qyw67xs.cloudfront.net/1030/rreps_residential-roof-thermo... · pre-finished ridge cap 0.55 flashing stopends to roof cladding

FOAM INFILL

TURN DOWN PAN APRROX20° (SPECIAL TOOLAVAILABLE)

4mm Ø STEEL RIVET

0.55mm BMT COLORSTEELFLASHING

PRE-FINISHED SELF-TAPPING 14g TEK SCREWWITH NEOPRENE WASHERTO EVERY RIB (TYPICAL)

PROFILLED FOAM CLOURESTRIP SEALED TOP &BOTTOM

BUTYL TAPE

TURN UP PAN TO FULL RIBHEIGHT(SPECIAL TOOL AVAILABLE)

0.55mm BMT COLORSTEELFLASHING

50mm ROOF STEP

DETAIL RECOMMENDEDWHERE ROOF RUNSEXCEED 16m

3° min.

STEP

50mm

RO

OF

5mm

GAP

METALCRAFT THERMOSPANPANEL

300 min. LAPX

SITUATION 1

1. LOW, MEDIUM, HIGH WIND ZONES,WHERE ROOF PITCH ≥ 10°

MIN. 130mm(EXCLUDDING ANY SOFT EDGE ORTURN-DOWN TO ROOFING)

SITUATION 2

1. ALL ROOF PITCHES IN VERY HIGHWIND ZONE2. LOW, MEDIUM, HIGH WIND ZONESWHERE ROOF PITCH ≤ 10°

MIN. 200mm(EXCLUDDING ANY SOFT EDGE ORTURN-DOWN TO ROOFING)

X

SITUATION 3

1. FOR ALL ROOF PITCHES INEXTRA HIGH WIND ZONES

CATEGORY A

1. NORMAL EXPOSURE2. ROOF PITCH >10°

MIN. 130mm

CATEGORY B

1. EXPOSED (HIGHER RISK) & WIND LOAD EXCEEDS 1.5 kPa.2. ROOF PITCH <10°

MIN. 200mmX

ALTERNATIVE SOLUTION AS PER MRM CODE OF PRACTICE

ACCEPTABLE SOLUTION AS PER E2/ASI

Reference

DISCLAIMER:All details are to be used for indicative purposes only and the designer should consult both the MRM code ofpractice version 2.2 /2012, E2 and all other relevant building codesDetails of the supporting mechanisms are indicative only. Compliance of the supporting mechanisms is theresponsibility of the designer.

RESIDENTIAL ROOFING

- BUILDING PAPER IS THE COMMON GENERIC NAME FOR PERMEABLEROOF AND WALL UNDERLAYS. PLEASE REFER TO NZBC E2/AS1 ANDMRM CODE OF PRACTICE VERSION 2.2 /2012.

* - PLEASE REFER TO MRM CODE OF PRACTICE VERSION 2.2 /2012 AS MINIMUM PITCH WILL INCREASE DEPENDING ON SHEET LENGTH.

ScaleDate Sheet

ThermoSpan Residental

RRTSMetalcraftInsulated Panel Systems 1 : 5

EXPANSION STEP DETAIL

15A / 2530.08.2016

Page 18: S: 5 Metalcraft Roofing01 WIP01 BIM© 2013 Drawing …dvgdd8qyw67xs.cloudfront.net/1030/rreps_residential-roof-thermo... · pre-finished ridge cap 0.55 flashing stopends to roof cladding

100mm MIN

150m

m M

IN

CHIMNEY

PRE-FINSHEDSOAKER FLASHINGNOTCHED OVER RIBS

METALCRAFT THERMOSPANRESIDENTIAL ROOFINGTURN DOWN INTO GUTTER

MIN 150mm UPSTAND PRE-FINISHED1.6mm ALUMINIUM WELDEDSOAKER FLASHING

A MIN. OF 100mm CLEARANCE MUSTBE PROVIDED BETWEEN THESHEETING UPSIDE OF THEPENETRATION AND THE BACK CURBUPSTAND, TO PROVIDE FOR ANDTEMPORARY OBSTRUCTION ORABNORMAL RUNOFF. THE BACKCURB MUST BE SUFFICENT INDEPTH TO PROVIDE 150mm ROOFINGCOVER AND ROOFING FASTNERSMUST NOT PENETRATE THISFLASHING.

ROOF UNDERLAY WITH MIN.5mm LAP INTO BACK CURB

SIDE CURB AND BACKCURB 50mm HIGHER THANTHE CLADDING PROFILE

FLASHING SOFT EDGEDRESSED INTO PROFILE

PRIMARY FIXINGFASTENING TO THESTRUCTURE

Reference

DISCLAIMER:All details are to be used for indicative purposes only and the designer should consult both the MRM code ofpractice version 2.2 /2012, E2 and all other relevant building codesDetails of the supporting mechanisms are indicative only. Compliance of the supporting mechanisms is theresponsibility of the designer.

RESIDENTIAL ROOFING

- BUILDING PAPER IS THE COMMON GENERIC NAME FOR PERMEABLEROOF AND WALL UNDERLAYS. PLEASE REFER TO NZBC E2/AS1 ANDMRM CODE OF PRACTICE VERSION 2.2 /2012.

* - PLEASE REFER TO MRM CODE OF PRACTICE VERSION 2.2 /2012 AS MINIMUM PITCH WILL INCREASE DEPENDING ON SHEET LENGTH.

ScaleDate Sheet

ThermoSpan Residental

RRTSMetalcraftInsulated Panel Systems 1 : 5

CHIMNEY PENETRATION DETAIL

16 / 2530.08.2016

Page 19: S: 5 Metalcraft Roofing01 WIP01 BIM© 2013 Drawing …dvgdd8qyw67xs.cloudfront.net/1030/rreps_residential-roof-thermo... · pre-finished ridge cap 0.55 flashing stopends to roof cladding

METALCRAFTTHERMOSPAN EPSROOFING

GUTTER

FASCIA FLASHINGØ5mm STEEL RIVETS @300mm CRS

HEAD BARGE FLASHING

TURN UP WEATHERPROOF

150

40

30

VAR

AIES

DEP

END

ENT

ON

RO

OF

PITC

H

5010

TO SUIT ROOF PITCH (90° - ROOF PITCH)

TO SUIT ROOF PITCH (90° + ROOF PITCH)

20

20

30

VAR

IES

DEP

END

ENT

ON

RO

OF

PITC

H

TO SUIT ROOF PITCH(90° - ROOF PITCH)

TO SUIT ROOF PITCH(90° + ROOF PITCH)

THERMOSPAN HEAD BARGE FLASHING THERMOSPAN FASCIA FLASHING

Reference

DISCLAIMER:All details are to be used for indicative purposes only and the designer should consult both the MRM code ofpractice version 2.2 /2012, E2 and all other relevant building codesDetails of the supporting mechanisms are indicative only. Compliance of the supporting mechanisms is theresponsibility of the designer.

RESIDENTIAL ROOFING

- BUILDING PAPER IS THE COMMON GENERIC NAME FOR PERMEABLEROOF AND WALL UNDERLAYS. PLEASE REFER TO NZBC E2/AS1 ANDMRM CODE OF PRACTICE VERSION 2.2 /2012.

* - PLEASE REFER TO MRM CODE OF PRACTICE VERSION 2.2 /2012 AS MINIMUM PITCH WILL INCREASE DEPENDING ON SHEET LENGTH.

ScaleDate Sheet

ThermoSpan Residental

RRTSMetalcraftInsulated Panel Systems 1 : 2

FASCIA AND BARGE FLASHING DIMENSIONS

17 / 2530.08.2016

Page 20: S: 5 Metalcraft Roofing01 WIP01 BIM© 2013 Drawing …dvgdd8qyw67xs.cloudfront.net/1030/rreps_residential-roof-thermo... · pre-finished ridge cap 0.55 flashing stopends to roof cladding

PRE-FINISHED RIDGE CAPFLASHING

METALCRAFT THERMOSPANTHERMOSPAN

PRE-FINISHED BARGE FLASHING

PURLIN

ROOF FRAMING

FASCIA BOARD

WALL CLADDING ON CAVITY

WALL FRAMING

* PLEASE REFER TO MRM CODEOF PRACTICE VERSION 2.2/2012AND RANZ HOW TO ON-SITEGUIDE METAL ROOF FLASHINGSFOR FURTHER INFORMATION ONFLASHING COVER WIDTHS.

Reference

DISCLAIMER:All details are to be used for indicative purposes only and the designer should consult both the MRM code ofpractice version 2.2 /2012, E2 and all other relevant building codesDetails of the supporting mechanisms are indicative only. Compliance of the supporting mechanisms is theresponsibility of the designer.

RESIDENTIAL ROOFING

ScaleDate Sheet

ThermoSpan Residental

RRTSMetalcraftInsulated Panel Systems

3D RIDGE TO BARGE JUCTION

18 / 2530.08.2016

Page 21: S: 5 Metalcraft Roofing01 WIP01 BIM© 2013 Drawing …dvgdd8qyw67xs.cloudfront.net/1030/rreps_residential-roof-thermo... · pre-finished ridge cap 0.55 flashing stopends to roof cladding

PRE-FINISHED RIDGE FLASHING

METALCRAFT THERMOSPAN PANELSTURN DOWN INTO GUTTERREFER TO EAVE DETAILS FORMINIMUM ROOF OVERHANG

PRE-FINISHED BARGE FLASHING

PRE-FINISHED APRONFLASHING

PRE-FINISHED HIP FLASHING

GUTTER

FASCIA BOARD

* PLEASE REFER TO MRM CODE OFPRACTICE VERSION 2.2/2012 AND RANZHOW TO ON-SITE GUIDE METAL ROOFFLASHINGS FOR FURTHER INFORMATIONON FLASHING COVER WIDTHS.

WALL CLADDING ON CAVITY

Reference

DISCLAIMER:All details are to be used for indicative purposes only and the designer should consult both the MRM code ofpractice version 2.2 /2012, E2 and all other relevant building codesDetails of the supporting mechanisms are indicative only. Compliance of the supporting mechanisms is theresponsibility of the designer.

RESIDENTIAL ROOFING

ScaleDate Sheet

ThermoSpan Residental

RRTSMetalcraftInsulated Panel Systems

3D DUTCH GABLE

19 / 2530.08.2016

Page 22: S: 5 Metalcraft Roofing01 WIP01 BIM© 2013 Drawing …dvgdd8qyw67xs.cloudfront.net/1030/rreps_residential-roof-thermo... · pre-finished ridge cap 0.55 flashing stopends to roof cladding

GUTTER

METALCRAFT THERMOSPANPANELSTURN DOWN INTO GUTTERREFER TO EAVE DETAILS FORMINIMUM ROOF OVERHANG

WALL CLADDING ON CAVITY

PRE-FINISHED APRON FLASHINGWITH HEMMED EDGE

PRE-FINISHED APRON DIVERTER

* PLEASE REFER TO MRM CODE OFPRACTICE VERSION 2.2/2012 ANDRANZ HOW TO ON-SITE GUIDE METALROOF FLASHINGS FOR FURTHERINFORMATION ON FLASHING COVERWIDTHS.

WALL CLADDING ON CAVITY

FASCIA BOARD

Reference

DISCLAIMER:All details are to be used for indicative purposes only and the designer should consult both the MRM code ofpractice version 2.2 /2012, E2 and all other relevant building codesDetails of the supporting mechanisms are indicative only. Compliance of the supporting mechanisms is theresponsibility of the designer.

RESIDENTIAL ROOFING

ScaleDate Sheet

ThermoSpan Residental

RRTSMetalcraftInsulated Panel Systems

3D APRON

20 / 2530.08.2016

Page 23: S: 5 Metalcraft Roofing01 WIP01 BIM© 2013 Drawing …dvgdd8qyw67xs.cloudfront.net/1030/rreps_residential-roof-thermo... · pre-finished ridge cap 0.55 flashing stopends to roof cladding

PRE-FINISHED SOAKERFLASHING

EPDM FLEXIBLE CONE SLEEVE

MALLEABLE FLANGE, SCREWOR RIVET FIXED, AND SEALEDTO ROOFING PROFILE. FITNEOPRENE WASHERS TO ALLSCREW FIXINGS. FITTED ON45° ANGLE IN PLAN. REFER TOMRM CODE OF PRACTICEVERSION 2 2/2012.

PRE-FINISHED ROOF RIDGEFLASHING

PIPE(DIAMETER OVER 85mmDIAMETER)

METALCRAFT THERMOSPANPANELS

PRE-FINISHED ROOF BARGEFLASHING

PRE-FINISHED SOAKERFLASHING LINE UNDER PRE-FINISHED ROOF RIDGE FLASHING

* PLEASE REFER TO MRM CODE OFPRACTICE VERSION 2.2/2012 ANDRANZ HOW TO ON-SITE GUIDEMETAL ROOF FLASHINGS FORFURTHER INFORMATION ONFLASHING COVER WIDTHS.

Reference

DISCLAIMER:All details are to be used for indicative purposes only and the designer should consult both the MRM code ofpractice version 2.2 /2012, E2 and all other relevant building codesDetails of the supporting mechanisms are indicative only. Compliance of the supporting mechanisms is theresponsibility of the designer.

RESIDENTIAL ROOFING

ScaleDate Sheet

ThermoSpan Residental

RRTSMetalcraftInsulated Panel Systems

3D OVER 85mm DIAMETER PIPE PENETRATION

21 / 2530.08.2016

Page 24: S: 5 Metalcraft Roofing01 WIP01 BIM© 2013 Drawing …dvgdd8qyw67xs.cloudfront.net/1030/rreps_residential-roof-thermo... · pre-finished ridge cap 0.55 flashing stopends to roof cladding

METALCRAFT THERMOSPANPANELS TURN DOWN INTOGUTTER

PRE-FINISHED APRONFLASHING

WALL CLADDING ON CAVITY

PREFINISHED VALLEY GUTTERPURLIN

PRE-FINISHED SOAKERFLASHING

VALLEY BOARD

ROOF FRAMING

MIN

. 110

mm

UPS

TAN

D

MIN. 110mm UPSTANDPRE-FINISHED 1.6mmALUMINIUM WELDEDSOAKER FLASHING

* PLEASE REFER TO MRM CODEOF PRACTICE VERSION 2.2/2012AND RANZ HOW TO ON-SITEGUIDE METAL ROOF FLASHINGSFOR FURTHER INFORMATION ONFLASHING COVER WIDTHS.

DIVERTER FLASHING ONUPPER SIDE OF CHIMNEY

Reference

DISCLAIMER:All details are to be used for indicative purposes only and the designer should consult both the MRM code ofpractice version 2.2 /2012, E2 and all other relevant building codesDetails of the supporting mechanisms are indicative only. Compliance of the supporting mechanisms is theresponsibility of the designer.

RESIDENTIAL ROOFING

ScaleDate Sheet

ThermoSpan Residental

RRTSMetalcraftInsulated Panel Systems

3D CHIMNEY PENETRATION

22 / 2530.08.2016

Page 25: S: 5 Metalcraft Roofing01 WIP01 BIM© 2013 Drawing …dvgdd8qyw67xs.cloudfront.net/1030/rreps_residential-roof-thermo... · pre-finished ridge cap 0.55 flashing stopends to roof cladding

Reference

DISCLAIMER:All details are to be used for indicative purposes only and the designer should consult both the MRM code ofpractice version 2.2 /2012, E2 and all other relevant building codesDetails of the supporting mechanisms are indicative only. Compliance of the supporting mechanisms is theresponsibility of the designer.

RESIDENTIAL ROOFING

ScaleDate Sheet

ThermoSpan Residental

RRTSMetalcraftInsulated Panel Systems

3D RIDGE/BARGE FLASHINGS

23 / 2530.08.2016

OPTION 1

RIDGE CAPFLASHING

ADDITIONALSADDLEFLASHING

BARGEFLASHING

RIDGE CAPFLASHING

ADDITIONALSADDLEFLASHING

BARGEFLASHING

OPTION 2

* PLEASE REFER TO MRM CODEOF PRACTICE VERSION 2.2/2012AND RANZ HOW TO ON-SITEGUIDE METAL ROOF FLASHINGSFOR FURTHER INFORMATIONON FLASHING COVER WIDTHS.

Page 26: S: 5 Metalcraft Roofing01 WIP01 BIM© 2013 Drawing …dvgdd8qyw67xs.cloudfront.net/1030/rreps_residential-roof-thermo... · pre-finished ridge cap 0.55 flashing stopends to roof cladding

(3) PRE-FINISHED 3DSADDLE FLASHING

(4) PRE-FINISHEDBARGE FLASHING

(2) PRE-FINISHEDAPRON FLASHING

(1) PRE-FINISHED HIP FLASHING

Reference

DISCLAIMER:All details are to be used for indicative purposes only and the designer should consult both the MRM code ofpractice version 2.2 /2012, E2 and all other relevant building codesDetails of the supporting mechanisms are indicative only. Compliance of the supporting mechanisms is theresponsibility of the designer.

RESIDENTIAL ROOFING

ScaleDate Sheet

ThermoSpan Residental

RRTSMetalcraftInsulated Panel Systems

3D DUTCH GABLE FLASHINGS

24 / 2530.08.2016

* PLEASE REFER TO MRM CODE OFPRACTICE VERSION 2.2/2012 AND RANZHOW TO ON-SITE GUIDE METAL ROOFFLASHINGS FOR FURTHERINFORMATION ON FLASHING COVERWIDTHS.

Page 27: S: 5 Metalcraft Roofing01 WIP01 BIM© 2013 Drawing …dvgdd8qyw67xs.cloudfront.net/1030/rreps_residential-roof-thermo... · pre-finished ridge cap 0.55 flashing stopends to roof cladding

THERMOSPAN EPS

A = 50, 75, 100, 125,150, 200, 250

A

1000

SCALE @ 1:5

SCALE @ 1:2

FLAT FINISH

32

- PLEASE NOTE FOR RESIDENTIAL ROOFING A MINIMUM THICKNESS OF150mm IS RECOMMENDED - CONTACT METALCRAFT

INTERNAL LINER FINISHES

SILKLINE FINISH

MESA FINISH

RIBBED FINISH

15 30

589 40 9

12

12 4 107

1

Reference

DISCLAIMER:All details are to be used for indicative purposes only and the designer should consult both the MRM code ofpractice version 2.2 /2012, E2 and all other relevant building codesDetails of the supporting mechanisms are indicative only. Compliance of the supporting mechanisms is theresponsibility of the designer.

RESIDENTIAL ROOFING

ScaleDate Sheet

ThermoSpan Residental

RRTSMetalcraftInsulated Panel Systems As indicated

PANEL PROFILE AND SIZE

25 / 2530.08.2016