RW DATA LOG RETRIEVAL GUIDE ARMSTRONG ULTRASONIC PORTABLE FLOW METER TOOLS: ARM-TB terminal box 12VDC wall charger USB-A to USB-mini cable (terminal box to computer) 15 pin communication cable (terminal box to AUP) RW Software Connect the AUP to the computer through the terminal box AUP using the cables as described above. Power the terminal box with the wall charger. Turn on the AUP. Certain operations in this program will take longer to execute than others, and may be interrupted with repeated actuation. On the computer, open the RW.exe program. Identify the com port that connects the USB cable to the terminal box (Control Panel, Device Manager, COM and LPT, silicon labs CP210x USB to UART bridge, com _). Set the COM port to match, and set the Baud rate to match the Baud rate of the AUP(Menu, 5, 3, ENT, select BAUD from menu. 9600 or higher recommended). Parity should be set to “NONE”. Move the cursor to the OPEN tab and open the com port. VERIS Flow Measurement Group 5820 Glacier Way, Frederick, CO 80516 303-652-8550

RW DATA LOG RETRIEVAL GUIDE ARMSTRONG ULTRASONIC …€¦ · RW DATA LOG RETRIEVAL GUIDE ARMSTRONG ULTRASONIC PORTABLE FLOW METER TOOLS: ARM-TB terminal box 12VDC wall charger USB-A

  • Upload
    others

  • View
    20

  • Download
    0

Embed Size (px)

Citation preview

Page 1: RW DATA LOG RETRIEVAL GUIDE ARMSTRONG ULTRASONIC …€¦ · RW DATA LOG RETRIEVAL GUIDE ARMSTRONG ULTRASONIC PORTABLE FLOW METER TOOLS: ARM-TB terminal box 12VDC wall charger USB-A

RW DATA LOG RETRIEVAL GUIDE ARMSTRONG ULTRASONIC PORTABLE FLOW METER

TOOLS: ARM-TB terminal box 12VDC wall charger USB-A to USB-mini cable (terminal box to computer) 15 pin communication cable (terminal box to AUP) RW Software

Connect the AUP to the computer through the terminal box AUP using the cables as described above. Power the terminal box with the wall charger. Turn on the AUP.

Certain operations in this program will take longer to execute than others, and may be interrupted with repeated actuation.

On the computer, open the RW.exe program. Identify the com port that connects the USB cable to the terminal box (Control Panel, Device Manager, COM and LPT, silicon labs CP210x USB to UART bridge, com _). Set the COM port to match, and set the Baud rate to match the Baud rate of the AUP(Menu, 5, 3, ENT, select BAUD from menu. 9600 or higher recommended). Parity should be set to “NONE”.

Move the cursor to the OPEN tab and open the com port.

VERIS Flow Measurement Group 5820 Glacier Way, Frederick, CO 80516 303-652-8550

Page 2: RW DATA LOG RETRIEVAL GUIDE ARMSTRONG ULTRASONIC …€¦ · RW DATA LOG RETRIEVAL GUIDE ARMSTRONG ULTRASONIC PORTABLE FLOW METER TOOLS: ARM-TB terminal box 12VDC wall charger USB-A

RW DATA LOG RETRIEVAL GUIDE ARMSTRONG ULTRASONIC PORTABLE FLOW METER

Open tab label will change to Close, and the screen confirms that the com port is open.

Move the cursor to the File Controller tab and open the data reading interface.

VERIS Flow Measurement Group 5820 Glacier Way, Frederick, CO 80516 303-652-8550

Page 3: RW DATA LOG RETRIEVAL GUIDE ARMSTRONG ULTRASONIC …€¦ · RW DATA LOG RETRIEVAL GUIDE ARMSTRONG ULTRASONIC PORTABLE FLOW METER TOOLS: ARM-TB terminal box 12VDC wall charger USB-A

RW DATA LOG RETRIEVAL GUIDE ARMSTRONG ULTRASONIC PORTABLE FLOW METER

Move the cursor to the Read SN tab and access the data logs stored on the AUP.

Position the cursor above the data log you wish to transfer. Click once to select this log (brackets appear).

Move the cursor to the white field below and click once. The Option Box appears.

Select “read file”.

VERIS Flow Measurement Group 5820 Glacier Way, Frederick, CO 80516 303-652-8550

Page 4: RW DATA LOG RETRIEVAL GUIDE ARMSTRONG ULTRASONIC …€¦ · RW DATA LOG RETRIEVAL GUIDE ARMSTRONG ULTRASONIC PORTABLE FLOW METER TOOLS: ARM-TB terminal box 12VDC wall charger USB-A

RW DATA LOG RETRIEVAL GUIDE ARMSTRONG ULTRASONIC PORTABLE FLOW METER

The selected log data populates the center field on the screen. Depending on log size, this may take several minutes. The data will move continually on the screen as it transfers from the AUP. When the data stops moving, transfer is complete.

Move the cursor to the “EXP Excel” tab and transfer the data to your computer.

NAME THE FILE WITH THE EXTENSION “csv”. This will ensure properly formatted data.

VERIS Flow Measurement Group 5820 Glacier Way, Frederick, CO 80516 303-652-8550

Page 5: RW DATA LOG RETRIEVAL GUIDE ARMSTRONG ULTRASONIC …€¦ · RW DATA LOG RETRIEVAL GUIDE ARMSTRONG ULTRASONIC PORTABLE FLOW METER TOOLS: ARM-TB terminal box 12VDC wall charger USB-A

RW DATA LOG RETRIEVAL GUIDE ARMSTRONG ULTRASONIC PORTABLE FLOW METER

The program will confirm the successful data transfer.

Select “OK” tab, then “Clear” and “Return” tabs to return to the previous screen, and exit the program.