8
RS3-FIM series Migration Don't let wiring costs prevent you from upgrading an RS3 FIM series system to a DeltaV system This document is the property of Firelec. No copy, even partial, allowed without prior writen authorization.

RS3-FIM series Migration

  • Upload
    dewei

  • View
    75

  • Download
    0

Embed Size (px)

DESCRIPTION

RS3-FIM series Migration. Don't let wiring costs prevent you from upgrading an RS3 FIM series system to a DeltaV system. This document is the property of Firelec. No copy, even partial, allowed without prior writen authorization. RS3-FIM series Migration. Using RIAs (RS3 Interface Adapters) : - PowerPoint PPT Presentation

Citation preview

Page 1: RS3-FIM series Migration

RS3-FIM series Migration

Don't let wiring costs prevent you from upgrading an RS3 FIM series system to a DeltaV system

This document is the property of Firelec. No copy, even partial, allowed without prior writen authorization.

Page 2: RS3-FIM series Migration

RS3-FIM series Migration

Using RIAs (RS3 Interface Adapters) : • Keeping existing I/O panels• Keeping I/O termination panels and associated process I/Os• Installing RIAs (RS3 Interface Adapters) on existing FIM series termination panels

This document is the property of Firelec. No copy, even partial, allowed without prior writen authorization.

Page 3: RS3-FIM series Migration

This document is the property of Firelec. No copy, even partial, allowed without prior writen

authorization.

RS3-FIM series Migration

FIM electronic module to be removed RIA to be plugged in place of existing FIM module

Using RIAs

Page 4: RS3-FIM series Migration

This document is the property of Firelec. No copy, even partial, allowed without prior writen

authorization.

RS3-FIM series Migration

RS3 ControlFile

Primary PeerWay

Secondary PeerWay

Using RIAs

Communication Termination Panel

Process I/OsFIM

Process I/OsFIM

Existing RS3 architecture

Page 5: RS3-FIM series Migration

This document is the property of Firelec. No copy, even partial, allowed without prior writen

authorization.

RS3-FIM series Migration

RS3 ControlFile

Primary PeerWay

Secondary PeerWay

PeerWay to be removed

Using RIAs

Communication Termination Panel

To be removed

To be removed

Process I/OsFIM

FIM to be replaced by the RIA

Process I/OsFIM

FIM to be replaced by the RIA

Devices to be removed

Page 6: RS3-FIM series Migration

This document is the property of Firelec. No copy, even partial, allowed without prior writen

authorization.

RS3-FIM series Migration

Using RIAs

I/O termination panels and associated I/Os are kept in place in the existing cabinets

Process I/Os

Process I/Os

Devices to be kept

Page 7: RS3-FIM series Migration

This document is the property of Firelec. No copy, even partial, allowed without prior writen

authorization.

RS3-FIM series Migration

Using RIAs

Process I/Os

Process I/Os

New DeltaV architecture

Secondary DeltaV Highway

Cnt

rl

PS

I/O

1

I/O

2

I/O

3

I/O

4

I/O

5

I/O

6I/

O7

I/O

8

Primary DeltaV Highway

Page 8: RS3-FIM series Migration

RS3-FIM series Migration

The End