10
ROOF TOP PACKAGE UNITS Inverter compressors, EC fans, double skin construction package units designed to suit your project requirements

ROOF TOP PACKAGE UNITS - Pacific Ventilation · type of commercial installation. This is achieved by the use of an inverter capacity scroll ... TENANCY FITOUTS, UNIVERSITY AND OFFICE

  • Upload
    others

  • View
    1

  • Download
    0

Embed Size (px)

Citation preview

Page 1: ROOF TOP PACKAGE UNITS - Pacific Ventilation · type of commercial installation. This is achieved by the use of an inverter capacity scroll ... TENANCY FITOUTS, UNIVERSITY AND OFFICE

ROOF TOP PACKAGE UNITSInverter compressors, EC fans, double skin construction package units designed to suit your project requirements

Page 2: ROOF TOP PACKAGE UNITS - Pacific Ventilation · type of commercial installation. This is achieved by the use of an inverter capacity scroll ... TENANCY FITOUTS, UNIVERSITY AND OFFICE

Delivering an extensive range, with capacities starting from 11kW up to 270kW and incorporating inverter technology throughout our roof top package units. Providing a genuine solution for a variety of projects, PacAir air-cooled SMART package units can be more economical and efficient than a chiller plant for a similar type of commercial installation.

This is achieved by the use of an inverter capacity scroll compressor, electronically commutated fans, free-cooling and reduced installation time. This means a SMARTPAC solution can form an integral part of a medium to long term sustainable energy strategy and help stores reduce their carbon footprint.

An evolution in design and custom engineered solutions for small, medium and large sized air conditioning applications, our SMART package units are technology and efficiency from tomorrow, delivered today.

Pacific HVAC Engineering are dedicated to providing market leading innovations and new technologies that are easy-to-use solutions with the goal to always offer our client reduced energy outlay whilst empowering complete control to customize the solution for their business.

High efficiency INVERTER scroll compressor technology combined with electronically commutated (EC) supply and condenser fans. A smart package unit capable of managing the strategy to deliver the most efficient cooling method on the market via inverter compressor, variable supply and condenser air, fresh air management and free cooling.

PacAir RTU’s are designed to operate from -15.0°C to 50.0°C ambient conditions. They are manufactured from double skin panels, ensuring thermal protection and longevity of equipment. Meeting MEPS regulations, AS3666 and AS3000 and incorporating an economizer as standard throughout, the entire range will ensure customer satisfaction.

The high level interface (HLI) controller will monitor space conditions and control air quality through an integrated CO2 probe, ambient conditions, humidity, free-cooling and complete variable capacity control, providing precise comfort and a reduced energy footprint.

Incorporating intelligent control technology with market leading inverter and EC components throughout the SMARTPAC range.

S H O P P I N G C E N T R E S , T E N A N C Y F I T O U T S , U N I V E R S I T Y A N D O F F I C E B U I L D I N G S

S M A RT PA C K A G E U N I T S

Page 3: ROOF TOP PACKAGE UNITS - Pacific Ventilation · type of commercial installation. This is achieved by the use of an inverter capacity scroll ... TENANCY FITOUTS, UNIVERSITY AND OFFICE

F I LT E R S A N D P L E N U MG4 pre-filter and F7 high filteration as standard. Optional F5/F6/F7 50 or 100mm panel filters available or H10 electronic filter systems.

H I G H L E V E L I N T E R FA C E C O N T R O L SPacAir RTU SMART controller can easily be integrated into Building Management Systems (BMS) that use BacNET IP as a communication protocol. Monitoring the SMARTPAC at high level, communicating to adjust set points, airflows, operating times, after hours and monitor any faults, alarms and the filter status. The serial connection port is built-in to the electronic board and is a standard feature throughout the range. SMARTPAC is also equipped with an IQ controller for the automatic control of all operating conditions, ambient temperature, humidity, CO2 and incorporates functions to maintain space conditions and optimize the running cost of the PacAir RTU all year round. With advanced maintenance and service functions scheduled, this package unit is setting a new level of expectations in the market.

C O M P R E S S O R ( S )Maximum electrical power is only required for certain periods of operation, maximum efficiency when operating at part load operation is essential. Continuous modulating control is obtained by using a compressor with inverter technolgy, which adapts to the actual requirements of the building load and space served.

E L E C T R O N I C E X PA N S I O N VA LV EOptimum control of superheat at varying operating conditions, providing outstanding comfort with indoor air temperature and humidity control. EXV increased efficiencies by lowering head pressure and optimum refrigerant supply to the heat exchanger coils.

D I S P L AYUser friendly wall mounted touch screen display pad, easy to understand menu, adjustable temperature set-point and display of current space temperature and humidity through its built-in sensors, 365/weekly/daily programming with after-hours control and fault status.

C O I L T R E AT M E N TCondenser coils are treated as standard with Aeris Coil Treatment. The evaporator coil can be treated as required and is optional based on project requirements.

FA N ( S )The selection of electronically commutated (EC) brushless motors reduces acoustics, heat and wasted energy. Allowing the EC fans to adjust speed by means of the condensing pressure or supply air temperature. Modulating the speed based on the actual requirements, maximizing the energy efficiency of the cooling circuit and simultaneously reducing the electrical load. The decreased air volume also has a significant effect on the reduced acoustic levels. With seasonal and night time functions continually controlled by the intelligent controller, allowing the unit to operate when maximum cooling or heating capacity is not required, saving power and reducing operating costs.

F R E E - C O O L I N GAs external ambient conditions change, the opportunity to provide free-cooling is incorporated into our high level interface controller. The unit is capable of automatically activating the free-cooling mode when conditions meet the controls internal algorithm and space conditions. Keeping the compressors off and drawing in suitably filtered fresh air allows to cool the space. This operating mode is especially useful during cooler periods and night time operation when high ambient conditions are reduced. It allows substantial reduction of the unit energy consumption.

R E F R I G E R A N TECO friendly R410a or R32a refrigerant is available. Package units are pre-charged.

R 4 1 0 A

Page 4: ROOF TOP PACKAGE UNITS - Pacific Ventilation · type of commercial installation. This is achieved by the use of an inverter capacity scroll ... TENANCY FITOUTS, UNIVERSITY AND OFFICE

R A D I A LFA N S

5 05 25 45 65 86 06 26 46 66 8d B ( A )

E C I N V E R T E RP L U G - FA N S

U P T O

d B ( A )R E D U C T I O N

11

E A S Y M A I N T E N A N C EPlug and play style package units with power and control wiring are easy to connect to the roof top unit. With a small, compact footprint, easy access to all components an easy replacement solution for old units. Reduced maintenance costs with dirty or fouled-filter detection through the controller interfacing with the BMS. Commissioning, service and maintenance contracts, as the Pacific HVAC Engineering Service Division is at your disposal.

L I F E C Y C L E I N C R E A S E DThe external rotor electric motor is driven by the continuous magnetic switching of the stator. The advantages are the lack of brushes and the particular power supply increase efficiency by 70%. The lifecycle increases, thanks to the elimination of the brushes’ natural abrasive erosion effect. The electronic control also includes a “soft start” solution, which drastically reduces the starting current of the fan and limits even more the system’s electrical commitment.

R E D U C E D O P E R AT I N G C O S T S A N D A C O U S T I C SThe SMARTPAC’s controller, cooling circuit, EC fans and high capacity filter sections provide the most efficient operating costs on the market. It is possible to achieve seasonal efficiencies by selecting and purchasing the best units the market has to offer. Reduced electrical consumption of up to 60% in comparison to traditional DOL solutions. As a result, this also reduces operating costs and the environmental impact of the system, achieved by reducing the amount of energy required for normal operation. The reduction in wear and tear by brushless fans not only improves energy but also reduces the acoustic levels and improves environmental standards.

I N V E R T E R S C R O L L C O M P R E S S O R S A N D E C I N V E R T E R P L U G - FA N S

A B S O R B E DP O W E R

FA N SC O M P R E S S O R

M I N

M A X

U P T O

P O W E RM O D U L AT I O N

88%

Page 5: ROOF TOP PACKAGE UNITS - Pacific Ventilation · type of commercial installation. This is achieved by the use of an inverter capacity scroll ... TENANCY FITOUTS, UNIVERSITY AND OFFICE

T Y P I C A L U N I T C O N F I G U R AT I O N

PA C A I R RT U 1 2 1 - 5 3 1 I N V

PA C A I R RT U 7 1 2 - 2 6 4 6 I N V

Page 6: ROOF TOP PACKAGE UNITS - Pacific Ventilation · type of commercial installation. This is achieved by the use of an inverter capacity scroll ... TENANCY FITOUTS, UNIVERSITY AND OFFICE

S U P P LY & R E T U R N A I R C O N N E C T I O N S

Page 7: ROOF TOP PACKAGE UNITS - Pacific Ventilation · type of commercial installation. This is achieved by the use of an inverter capacity scroll ... TENANCY FITOUTS, UNIVERSITY AND OFFICE

F E AT U R E S

R E T U R N A I R A N D E C O N O M Y

D A M P E R S

H I G H L E V E L I N T E R FA C E C O N T R O L S

H A I L G U A R DE C P L U G FA N

I N V E RT E R S C R O L L

C O M P R E S S O R

FA C T O RY C O I L T R E AT M E N T

C A R E L P G D T O U C H D I S P L AY

0 - 1 0 V M O T O R I S E D C O N T R O L F O R V C D S

P R E F I LT E R S A N D D E E P B E D F I LT E R S

Page 8: ROOF TOP PACKAGE UNITS - Pacific Ventilation · type of commercial installation. This is achieved by the use of an inverter capacity scroll ... TENANCY FITOUTS, UNIVERSITY AND OFFICE

T E C H N I C A L D ATA

MODEL RTU # 121 INV 151 INV 181 INV 241 INV 301 INV 361 INV 441 INV 531 INV 712 INV 882 INV 1062 INV 1242 INV 1414 INV 1764 INV 2114 INV 2646 INV

COOLING CAPACITY kWr 11.7 14.6 17.6 23.4 29.3 35.2 43.9 52.7 70.3 87.9 105.5 123.1 140.6 175.8 211.0 263.7

HEATING CAPACITY kWr 12.9 16.1 19.3 25.8 32.2 38.7 48.3 58.0 77.4 96.7 116.0 135.4 154.7 193.4 232.1 290.1

AIRFLOW (NOMINAL) l/s 630 790 950 1250 1575 1890 2360 2840 3780 4730 5670 6620 7560 9170 10840 13620

STATIC (TSP) Pa 600 700 750 750 750 750 750 750 1000 1000 1000 1000 1000 1000 1000 1000

PRE FILTER Type G4 G4 G4 G4 G4 G4 G4 G4 G4 G4 G4 G4 G4 G4 G4 G4

MEDIUM FILTER Type F7 F7 F7 F7 F7 F7 F7 F7 F7 F7 F7 F7 F7 F7 F7 F7

EER 3.8 3.7 3.4 3.2 3.5 3.6 3.3 3.6 3.5 3.3 3.5 3.5 3.5 3.3 3.5 3.3

COP 4.7 4.6 4.1 3.9 4.3 4.3 4.1 4.4 4.3 4.1 4.3 4.3 4.3 4.0 4.2 4.0

POWER SUPPLY V/Ph/Hz <---------------------------------------------------------------------------------------------------------- 380-435 / 3 / 50 ------------------------------------------------------------------------------------------------------->

FULL LOAD CURRENT AMP 12.7 13.9 19.8 26.7 27.6 27.3 37.2 39.1 54.6 74.4 86.2 89.4 109.2 139.8 163.4 205.2

RUNNING CURRENT (maximum TSP) AMP 7.8 10.6 15.6 20.1 21.3 22.9 27.8 33.3 46.2 55.6 67.2 78.1 92.4 112.2 135.5 168.2

POWER CONSUMPTION (maximum TSP)

kW 3.1 3.9 5.2 7.4 8.4 9.9 13.2 14.8 20.2 26.4 30.0 35.1 40.4 53.7 61.1 80.4

REFRIGERANT <--------------------------------------------------------------------------------------------------------------- R410a ------------------------------------------------------------------------------------------------------------>

CIRCUITS QTY 1 1 1 1 1 1 1 1 2 2 2 2 4 4 4 6

COMPRESSORS QTY 1 1 1 1 1 1 1 1 2 2 2 2 4 4 4 6

CAPACITY STEPS <--------------------------------------------------------------------------------------------------------------- 25 -- 100 ------------------------------------------------------------------------------------------------------------>

SPL (ISO 3744) dBA 50 52 54 55 55 59 60 61 61 62 62 65 66 67 70 70

DIMENSIONS

WIDTH mm 1650 1650 1650 1650 1800 1800 1800 1800 2200 2200 2200 2200 2200 2200 2200 2200

LENGTH mm 2000 2000 2200 2200 2250 2350 2950 2950 2200 2820 3150 4400 4900 5150 5300 7000

HEIGHT mm 1200 1200 1200 1550 1550 1600 1600 1800 2280 2280 2280 2280 2280 2280 2280 2280

WEIGHT kg 390 420 490 550 650 750 950 1250 1520 1560 2130 2240 2500 2930 3190 3890

M O D E L R E F E R E N C E C O D E E X A M P L E

RT U 1 2 4 2 I N V

Roof top air cooled package unit

R410a series 400-415V/3PH/50Hz

Full inverter series

NOMINAL KW

NO OF INDEPENDENT

SYSTEM(S)

12 1

15 1

18 1

24 1

30 1

36 1

44 1

53 1

71 2

88 2

106 2

124 2

141 4

176 4

211 4

264 6

MODEL

121

151

181

241

301

361

441

531

712

882

1062

1242

1414

1764

2114

2646

Page 9: ROOF TOP PACKAGE UNITS - Pacific Ventilation · type of commercial installation. This is achieved by the use of an inverter capacity scroll ... TENANCY FITOUTS, UNIVERSITY AND OFFICE

N O T E S

Page 10: ROOF TOP PACKAGE UNITS - Pacific Ventilation · type of commercial installation. This is achieved by the use of an inverter capacity scroll ... TENANCY FITOUTS, UNIVERSITY AND OFFICE

Pacific HVAC Engineering Brisbane197 Murarrie Road Murarrie Queensland 4172 Australia

Pacific HVAC Engineering Melbourne63 Wells Road Chelsea Heights Victoria 3196 Australia

Pacific HVAC Engineering Sydney42 Plasser Cresent North St Marys New South Wales 2760 Australia

Pacific HVAC Engineering Auckland52 Arrenway Drive Rosedale Auckland 0632 New Zealand

pacifichvac.com

AU29681

Service and Warranty

Turner Engineering Perth102 Discovery Drive Bibra Lake Western Australia 6163 Australia

Pacific HVAC Engineering Adelaide601 Anzac Highway Glenelg North South Australia 5045 Australia

[email protected]

1300 733 833 (AU)0800 100 326 (NZ)

1300 664 506 (AU)0800 100 326 (NZ)[email protected]

For more information on our latest projects, visit www.pacifichvac.com

Please refer to our website for our terms and

conditions

Grafton Correctional Centre New South Wales

Woolworths Stirling Western Australia

Amazon Warehouse Victoria

Toombul Shopping Centre Queensland

R E C E N T P R O J E C T S

Yamanto Shopping Centre Queensland

The Nook Studios Victoria