    The KOTA SUPER THERMEL POWER STATION isideally located on the left bank of Chambal River at theupstream of KOTA BARRAGE

    Total Generation Capacity 1240 MW

    Stage I (Two units each of 110 MW)Stage II (Two units each of 210 MW)

    Stage III (One unit of 210 MW)Stage IV (One unit of 195 MW)Stage V (One unit of 195 MW)

  • 8/6/2019 ROHIT VIJAY

    3/22

    Water availabilityin large amount.

    Concentration of load in region.

    Continue power supply.

    Coal availability.

    Central grid location.

  • 8/6/2019 ROHIT VIJAY

    4/22

  • 8/6/2019 ROHIT VIJAY

    5/22

    Generator

    Transformer

    Motor

    Coal Handling PlantAsh Handling Plant

    Water Treatment Plant

    Switch Gear

    Switch YardSwitch Yard

    ProtectionProtection

    Auxiliary SupplyAuxiliary Supply

    Control RoomControl Room

    TurbineTurbine

    BoilerBoiler

    ElectroElectro--StaticStatic

    PrecipitatorPrecipitator

  • 8/6/2019 ROHIT VIJAY

    6/22

  • 8/6/2019 ROHIT VIJAY

    7/22

  • 8/6/2019 ROHIT VIJAY

    8/22

  • 8/6/2019 ROHIT VIJAY

    9/22

    Switchgear Employed for the protection of Inductionmotor.

    Generally two basic protectionviz short circuitprotection and overload protection are provided foreach motor.

    The Switchgear used for protection includes

    contractors with H.R.C. fuse and thermal overloadrelays along with CB.

  • 8/6/2019 ROHIT VIJAY

    10/22

    1) PHASE TO PHASE FAULT

    2) EARTH FAULT

    3) INTER-TURN FAULT

    1) CONDUCTOR TO EARTH FAULT

    2) BEARING FAILURE

    3) FAULT IN STARTER & ASSOCIATED CIRCUITS

  • 8/6/2019 ROHIT VIJAY

    11/22

    y OVERLOADING

    y STALLINGy UNBALANCE SUPPLY VOLTAGES

    y SINGLE PHASING

    y

    UNDER VOLTAGEy REVERSE PHASE

  • 8/6/2019 ROHIT VIJAY

    12/22

    Earth leakage Core balance CT and

    Relay

    Earth fault Earth Return CT

    Unbalance 3Phase CT and Relay

    Overload Thermal overload relay

    Over current IDMT Relay

    Stalling Motor protection relay

    Short circuit Instantaneous relays

    Fuses

    Differential Basically for earth fault

    within a particular zone.

    CT on both sides

    Under Voltage UV Relay

    Over Voltage Over Voltage Relay

    Unbalance Single Phase Preventers

    Single Phasing

  • 8/6/2019 ROHIT VIJAY

    13/22

  • 8/6/2019 ROHIT VIJAY

    14/22

    y It is used below 1000v.

    y Three phase supplyis given to the motor throughvarious elementssuch as fuse, Switch,contactor &thermal overload relay.

    y

    Magnetic contactor

    starter con

    sist of a

    set of

    start an

    dstop push buttons with associated contacts.

  • 8/6/2019 ROHIT VIJAY

    15/22

  • 8/6/2019 ROHIT VIJAY

    16/22

  • 8/6/2019 ROHIT VIJAY

    17/22

  • 8/6/2019 ROHIT VIJAY

    18/22

    This method to provide earth fault protection is calledcore balance type protection.

    It is also calledzero sequence current transformer.

    It is preferred the system with neutral earthed wiresystem.

  • 8/6/2019 ROHIT VIJAY

    19/22

  • 8/6/2019 ROHIT VIJAY

    20/22

    It is based on the electromagnetic principle.

    Rev

    erse pha

    se protect

    ion mu

    st be pro

    vide

    dinElevators , cranes, trams etc.

    Now a dayssolidstate phase reversal relaysensing thephase reversal is used.