Upload
vutruc
View
218
Download
4
Embed Size (px)
Citation preview
K.500.V03.GB
ROBATIC®
ROBA®-quickROBA®-takt
Electromagnetic Clutches and Brakes,Clutch Brake Units
● High torque capacity● Low wear● Easy assembly and maintenance● Compact construction
Reliable couplingand brakingReliable coupling and braking
System constructionPackaging machinesConveyor beltsDoor drivesIndexing tables
ww
w.
.de
your reliable partner
powertransmission
®
�
Your advantages when using Electromagnetic
ROBATIC®-Clutches, ROBA®-quick Brakes and
ROBA®-takt Clutch Brake Units• Easy integration into your machine:
The optimised magnetic circuit minimises the magnetic stray flux. The high power density and torque security based on it allow compact dimensions and an easy integration in your construction.
• High reliability and operational security:The switching behaviour is constant during the whole service life. Therefore, the positioning accuracy and reliability of the clutches or brakes respectively and herewith operational security of your machine are increased.
• Less operating expenses and maintenance charges:The large friction surface and the smooth switching behaviour increase the wear resistance, therefore, the clutches and brakes are maintenance-free until the friction faces are worn down.
• Increase of the productivity:Short switching times allow high switching frequency and increase the productivity of your machine.
All products are subject to comprehensive inspections and tests regarding loads. Only after having passed the strongest long-time tests and when they fully meet all the technical requirements and proof their reliability they are included in our delivery programme.
Please Observe:According to German notation, decimal points in this document are represented with a comma(e.g. 0,5 instead of 0.5).
Product quality
No delivery leaves our company without first being subjected to a careful quality inspection, so that customers are able to rely 100 % on mayr products. If requested, we adjust your clutches and brakes to the exact values required, and confirm the product characteristics using an inspection form.
Quality management
The term "quality" refers at mayr® to products and service performance. The certification of our quality management confirms the quality-consciousness of our colleagues at all levels within the company. Our management system is certified according to DIN EN ISO 9001:2000 (quality) and DIN EN ISO 14001 (the environment), and complies with the OHSAS 18001/OHRIS (employment protection) requirements.
Total Quality Management
powertransmission
®
�
Electromagnetic Clutches and Brakes
Description and Operational Conditions
1. The catalogue values, in particular the values for the nominal torque, are reference values and may deviate in individual cases.
�. During dimensioning, please contact the manufacturers for consultation on installation conditions, torque fluctuations, permitted friction work, run-in behaviour, wear and ambient conditions.
�. The clutches and brakes are designed for dry running. If the friction surfaces come into contact with oil, grease or similar substances, there may be a severe decrease in torque.
4. When the devices are switched off, voltage peaks may occur due to the counter-induction on the magnetic coils, causing in extreme cases damage to the magnetic coil and therefore to the components. For this reason, excess voltage must be damped using a suitable “protective circuit” (e.g. using a varistor).
5. The surfaces on the clutches and the brakes are corrosion-protected except for the friction surfaces. However, in operation in extreme ambient conditions or in outdoor conditions with direct weather influences, additional protective measures are necessary.
6. The connection cable or connection strands on the clutches and brakes have a surface coating which is not resistant against all influences. After contact with chemical substances, please check compatibility.
7. The clutches and brakes are designed for a relative duty cycle of 100 %.
Torque Characteristics
In new condition, c. 50 % of the catalogue nominal torque (M2) is transmitted.
The components reach the catalogue nominal torque when the friction surfaces are run in. As a rough guideline value, c. 100 – �00 switchings in dynamic operation, a typical speed (c. 50 to 1000 rpm) and a medium friction work (see Table 1) can be given.Longer slipping of the clutch or brake is to be avoided, especially at low speeds, as this can cause scoring formation and therefore damage to the friction surfaces.Clutches or brakes used in static or virtually static operation do not reach the nominal torque (M�) given in the Technical Data.
If requested, the clutches or brakes can also be run in at the place of manufacture. This is most expedient for the Type 540.140 with complete bearing.However, the Types 500.1_ _ and 5�0.1_ _ can also be run in under certain conditions. For this, please ensure exact installation customer-side according to the regulations in order to reproduce the friction conditions as exactly as possible. At the same time, the “friction carbon” produced must not be rubbed off.If the clutch is run in to the nominal torque at the place of manufacture and then operated in static or virtually static mode, please allow for a drop to c. 60 – 70 % of the nominal torque. This is the case if the clutch or brake falls below the speed or friction work (Qa) given in Table 1.For static and virtually static applications, we therefore recommend our, „double-cut designs“, construction series 500.�_ _.0 (available on demand).
Run-in Conditions
For running in, different procedures can be used according to the Type design. The respective application should also be individually taken into account.An “artificial” run-in is to be carried out if a run-in procedure is not possible in the machine due to the type of application (see section “Torque Characteristics”), e.g. due to insufficient friction work, speed or switching frequencies.
Clutch and brake Type
Run-in Possibility 1 Run-in Possibility �
ROBATIC®:
500.20_.0500.21_.0
ROBA-quick®:
520.20_.0520.21_.0
– Voltage c. ½ to 1/� of Unom– Speed c. �00 – 500 rpm– Synchronising against blocked output – Cycle c. 50 – 100 ms (acc. size); slipping should take no longer; break c. �00 ms synchronise c. �-� minutes (100 – �00 cycles)Observe: carry out torque inspection only in static mode – no slipping (danger of scoring formation)
– Synchronising against unblocked output while a larger rotating mass is produced, and / or
– Synchronising at a higher speed (values should lie above the minimum values in Table 1)– Allow to synchronise for c. � – � minutes
Observe: carry out torque inspection only in static mode – no slipping (danger of scoring formation)
ROBATIC®:
500.10_500.11_580.1_0540.1_ _540.14_
ROBA-quick®:
520.1_0
– Voltage c. 1/� of Unom (do not apply nominal voltage)! – Speed Sizes � - 6: c. 50 rpm Sizes 7 - 9: c. �0 rpm– c. � – � minutes Slipping against blocked output
– Synchronising against unblocked output while a larger rotating mass is produced, and/or – Synchronising at a higher speed (values should lie above the minimum values in Table 1)– allow to synchronise for c. � – � minutes
Table �
Explanation of Terms Used
The torque (nominal)(= switching torque) is the torque having an effect on the drive line on a slipping clutch or brake.
The transmittable torqueIs the largest torque with which the closed clutch or brake can be loaded without slipping occurrence.
The relative duty cycleIs the relationship of the duty cycle to the duration of backlash in
Size Friction work QaClutch or brake speed nmin [rpm]
� 16 �00
4 �9 �50
5 55 �00
6 105 160
7 �00 1�0
8 �80 1�0
9 600 100
Table 1
Manufacturer’s declarationmayr®-clutches and mayr®-brakes are to be seen as an option or component for installation into machines or equipment according to the machinery directive.The machinery must not be put into service until the machinery into which it is to be incorporated has been declared in conformity with the provisions of the applicable EC-directives.The product corresponds to the low-voltage directive �006/95/EC.
powertransmission
®
4
ROBATIC®
ElectromagneticEnergise to engagePole face clutches
Pages 5 to 18
ROBA®-quickElectromagneticEnergise to engagePole face brakes
Pages 19 to 27
ROBA®-takt Clutch Brake ModuleClutch Brake Units
Pages 28 to 36
Table of contents
powertransmission
®
5
Constant switching performancethroughout the total service life
High torque securitydue to an optimised magnetic field and the new design of the ROBATIC®-clutch. Therefore, higher capacities due to few magnetic field losses.
Half the weardue to large friction surfaces and smooth switching behaviour the ROBATIC®-clutch has a higher wear resistance (approx. 100 %).
Low noise
Short switching times/high switching frequencies
Correct function until end of wear
Large permissible shaft diameters due to large internal diameters of the magnetic coil bodies.
ROBATIC® Electromagnetic Clutch
powertransmission
®
6
FunctionROBATIC®-clutches are „energise to engage“, electromagnetic pole face units.
If a DC voltage is applied to the magnetic coil (1) a magnetic field is formed, the armature disc (�) is attracted to the rotor (�) and friction lining (4). The torque is transmitted via a friction connection.
The torque is transmitted from the drive element (6) via the armature disc (�) and the rotor (�) to the output shaft (7).
After having de-energised the coil, the membrane spring (5) draws back the armature disc (�) to the drive element (e.g. belt pulley), and the torque transmission is then disconnected.
7 1 2 4 6
3 5
ROBATIC® Electromagnetic Clutch
powertransmission
®
7
ROBATIC® -standard
Page 8
ROBATIC® – small mounting diameter
Page 11
ROBATIC® – with bearing supported coil carrier
Page 13
ROBATIC® – with bearing supported output flange
Page 14
Technical explanations
Page 15
Electrical accessories
Page 37
ROBATIC® summary of components
powertransmission
®
8
Standard Sizes 3 – 7 Type 500.20_.0
Technical data and dimensions Nominal Max. Electrical Mass moment of inertia Iown [10-4 kgm2] Weight G [kg] torque *) Speed Power M2 n P20 Rotor 2) Armature Flange hub 2) Without With Size [Nm] [rpm] [W] disc +armature disc accessories flange hub
� 10 8600 18 � 0,76 1,0� 0,68 0,75 4 �0 7000 �6 5,14 1,9� �,75 1 1,�1 5 45 6100 �7 1�,�5 6,86 8,6� �,15 �,�5 6 80 5800 5� �9,85 17,56 �4,66 �,48 4,0� 7 160 4500 79 86,75 5�,86 70,6� 6,6 7,5
Preferred Preferred Permissible bores bores shaft misalignment Size a b D D1 D2 dmin dmax dH7 d1min d1max d1
H7 G g V V1
� 0,� 4,5 7�,5 80 70 9 �5 10, 15 9 �0 17, �0 �6 �9,5 0,05 0,1 4 0,� 4 9� 100 88 11 �5 17, �0 1� �0 �0, �5 49 44 0,05 0,15 5 0,� 5,5 115 1�5 110 1� 4� �0, �5, �0 15 �5 1) �5, �0 57,5 47 0,05 0,15 6 0,� 5,5 140 150 140 1� 55 �5, �0, �5 �0 45 �0, 40 74 66 0,05 0,15 7 0,� 7,5 177 190 170 �0 65 �0, 40, 50 �� 60 40, 50 95 84 0,1 0,�
Size Hh9 K k L L1 L2 I I1 I2 M M1 O s s1 t t1 W ZH8 z
� 80 � x 4,6 1,7 �8,1 �4 �0 �0,5 �,5 16 60 7� 48,1 4 x 4,8 � x M4 �,9 5 5 4� �,5 4 100 � x 6,4 1,7 �1,� �6,5 �� �� 4,� 17 76 90 5�,� 4 x 5,7 � x M5 4,5 6,9 5 5� 4,5 5 1�5 � x 7,0 �,5 �6,1 �0 �8 �5 5,� �� 95 11� 64,1 4 x 6,8 � x M6 5,9 8,7 6 6� 5 6 150 � x 10,4 �,8 40,9 ��,5 �� �7,5 6 �5 1�0 1�7 7�,9 4 x 6,8 � x M8 7,1 8,5 8 80 6 7 190 � x 10,� �,7 46,� �7,5 �6 �1,5 7 �7 150 175 8�,� 4 x 9,� � x M8 8,� 10,1 8 100 6
1) Up to Ø �� keyway to DIN 6885/1, above Ø �� keyway to DIN 6885/� Standard voltages �4 VDC; 104 VDC.�) With max. bore Permissible voltage tolerances to IEC �8 +/-10 %.*) Please observe run-in regulations or minimum speed (see page �). We reserve the right to make dimensional and design alterations.
Order example:
To be included when ordering, size type voltage bore bore please state: [V DC] Ø dH7 Ø d1
H7
order number: 500.�0_.0� – 7 without accessories . . . . 0 flange hub. . . . . . . . . . . . 1
Example: Order number 6/500.�01.0/�4/�5/40
according to size(only with flange hub)
according to size
�4; 104 V-coils
Type 500.�00.0 Standard Type 500.�01.0
Standard with flange hub
➤➤➤
➤ ➤ ➤➤ ➤
➤
➤
➤
cable length: 400 mmdisplacedto bores by 45°
rectifier
mains ~
ROBATIC® Electromagnetic Clutch
powertransmission
®
9
Preferred Permissible bores shaft misalignment Size a b D D1 dmin dmax dH7 F3) G V V1
8 0,5 8 19� �00 �4 70 40, 50, 60 - 91 0,1 0,� 9 0,5 9 �51 �51 �4 80 50, 60, 70 - 111 0,1 0,�5
Nominal Max. Electrical Mass moment of inertia Iown [10-4 kgm2] Weight G [kg] torque *) speed power M2 n P20 Rotor 2) Armature Flange hub 2) Without Size [Nm] [rpm] [W] disc +armature disc accessories
8 ��0 �000 61 165 81 107 10,1 9 640 ��00 8� 450 �15 �81 �0,5
Standard Sizes 8 – 9 Type 500.100 500.102
Size Hh9 K k L I I1 I4 i M M1 N s s1 t t1 ZH8 z
8 ��0 � x 11 � 55,1 44 40 5 8 158 �15 9�,9 4 x 9 � x M10 10,6 8,5 100 4 9 �90 4 x �0 4,� 6�,9 51 47 6 9,5 �10 �70 116,8 4 x 11 4 x M1� 1�,4 11,8 1�5 4
�) With max. bore Standard voltage �4 VDC.�) Turning for RS-ball bearing according to order regulations – Permissible voltage tolerances to IEC �8 +/-10 %.
no turning is allowed for in the standard range. We reserve the right to make dimensional and design alterations.*) Please observe run-in regulations or minimum speed (see page �).
Technical data and dimensions
Type 500.10�Standard with connecting terminal
Type 500.100Standard
Order example:
To be included when ordering, size type voltage bore please state: [V DC] Ø dH7 �)
order number: 500.10_8 – 9 power cable ............0 terminal....................�
Example: Order number 8/500.100/�4/40
according to size
�4 V-coil
➤
➤➤
➤ ➤ ➤ ➤
➤
➤
ROBATIC® Electromagnetic Clutch
powertransmission
®
10
Size Hh9 K k L2 I I1 I2 I4 M1 N O s W ZH8 z
8 ��0 � x 11 � 45,� 44 40 �6,� 5 �15 9�,9 100,4 4 x 9 15 100 4 9 �90 4 x �0 4,� 5�,9 51 47 4�,9 6 �70 116,8 117,8 4 x 11 �0 1�5 4
Standard Sizes 8 – 9 Type 500.11_
Technical data and dimensions Nominal Max. Electrical Mass moment of inertia Iown [10-4 kgm2] Weight G [kg] torque *) speed power M2 n Typ P20 Rotor 2) Flange hub 2) Without With Size [Nm] [rpm] 500 [W] +armature disc accessories flange hub
8 ��0 �000 61 165 107 10,1 1� 9 640 ��00 8� 450 �81 �0,5 �5
Preferred Preferred Permissible bores bores shaft misalignment Size a b D D1 D2 dmin dmax dH7 d1min d1max d1
H7 F3) g V V1
8 0,5 8 19� �00 185 �4 70 40, 50, 60 �4 60 40, 50 - 84 0,1 0,� 9 0,5 9 �51 �51 �4� �4 80 50, 60, 70 �7 80 50, 60 - 104 0,1 0,�5
�) With max. bore Standard voltage �4 VDC.�) Turning for RS-ball bearing according to order regulations – Permissible voltage tolerances to IEC �8 +/-10 %.
no turning is allowed for in the standard range. We reserve the right to make dimensional and design alterations.*) Please observe run-in regulations or minimum speed (see page �).
Type 500.110Standard with flange hub
Order example:
To be included when ordering, size type voltage bore bore please state: [V DC] Ø dH7 Ø d1
H7
order number: 500.11_8 – 9 power cable ............0 terminal ...................�
Example: Order number 8/500.110/�4/40/40
according to size
according to size
�4 V-coil
➤
➤➤
➤ ➤ ➤➤ ➤
➤
➤
➤
ROBATIC® Electromagnetic Clutch
powertransmission
®
11
Small mounting diameter Sizes 3 – 7 Type 500.21_.0
Technical data and dimensions Nominal Max. Electrical Mass moment of inertia Iown [10-4 kgm2] Weight G [kg] torque *) speed power M2 n P20 Rotor 2) Armature Flange hub 2) Without With Size [Nm] [rpm] [W] disc +armature disc accessories flange hub
� 10 8600 18 �,� 0,7 0,8 0,65 0,7 4 �0 7000 �6 5,� 1,79 1,97 1,1 1,16 5 45 6100 �7 1�,47 6,�8 7,19 �,1 �,�5 6 80 5800 5� ��,�1 15,77 17,45 �,4 �,6 7 160 4500 79 90,1� 48,1 55,� 6,4 6,95
Preferred Preferred Permissible bores bores shaft misalignment Size a b D D1 D2 dmin dmax dH7 d1min d1max d1
H7 G g V V1
� 0,� 4,5 7�,5 80 54 9 �0 10, 15 8 17 10, 15 �6 �7 0,05 0,1 4 0,� 4 9� 100 70 11 �8 17, �0 9 �0 17, �0 49 �9,5 0,05 0,15 5 0,� 5,5 115 1�5 88 1� �5 �0, �5, �0 1� �0 �0, �5 57,5 44 0,05 0,15 6 0,� 5,5 140 150 110 1� 4� �5, �0, �5 15 �5 1) �5, �0 74 47 0,05 0,15 7 0,� 7,5 177 190 140 �0 55 �0, 40, 50 �0 45 �0, 40 95 66 0,1 0,�
Size Hh9 K k L L1 L2 I I1 I2 M M1 O s s1 t t1 W ZH8 z
� 80 � x 4,� 1,5 �8,1 �4 15 �� �,5 11,5 46 7� 4�,1 4 x 4,5 � x M� �,9 4,0 5 �5 � 4 100 � x 4,6 1,7 �1,1 �6,5 �0 �4 4,� 16 60 90 51,1 4 x 5,7 � x M4 4,4 5,0 5 4� �,5 5 1�5 � x 6,4 1,5 �6,1 �0 �� �7 5,� 17 76 11� 58,1 4 x 6,8 � x M5 5,9 6,8 6 5� � 6 150 � x 7 �,� 40,8 ��,5 �8 �0 6 �� 95 1�7 68,8 4 x 6,8 � x M6 7,0 8,5 8 6� �,5 7 190 � x 10,4 �,7 45,9 �7,5 �� �4 7 �5 1�0 175 77,9 4 x 9,� � x M8 8,1 8,4 8 80 �,5
1) Up to Ø �� keyway to DIN 6885/1, above Ø �� keyway to DIN 6885/� Standard voltages �4 VDC; 104 VDC.�) With max. bore Permissible voltage tolerances to IEC �8 +/-10 %.*) Please observe run-in regulations or minimum speed (see page �). We reserve the right to make dimensional and design alterations.
Order example:
To be included when ordering, size type voltage bore bore please state: [V DC] Ø dH7 Ø d1
H7
order number: 500.�1_.0� – 7 without accessories .......0 flange hub ......................1
Example: Order number 6/500.�11.0/�4/40/�0
according to size(only with flange hub)
according to size
�4; 104 V-coils
Type 500.�10.0Small mounting diameter Type 500.�11.0
Small mounting diameter with flange hub
➤➤➤
➤ ➤ ➤➤ ➤
➤
➤
➤
cable length:400 mm displacedto bores by 45°
rectifier
mains ~
ROBATIC® Electromagnetic Clutch
powertransmission
®
1�
To be included when ordering, size type voltage bore bore please state: [V DC] Ø dH7 Ø d1
H7
Small mounting diameter Sizes 8 – 9 Type 580.1_0
Technical data and dimensions Nominal Max. Electrical Mass moment of inertia Iown [10-4 kgm2] Weight G [kg] torque *) speed power M2 n P20 Rotor 1) Armature Flange hub 1) Without With Size [Nm] [rpm] [W] disc +armature disc accessories flange hub
8 ��0 �000 74 165 81 107 10,1 1� 9 640 ��00 77 450 �15 �81 �0,5 ��,5
Preferred Preferred Permissible bores bores shaft misalignment Size a b D D1 D2 dmin dmax dH7 d1min d1max d1
H7 G g V V1
8 0,5 � 19� �00 185 �4 70 40, 50, 60 �4 60 40, 50 91 84 0,1 0,� 9 0,5 � �51 �51 �4� �4 80 50, 60, 70 �7 80 50, 60 111 104 0,1 0,�5
Size K k L L2 I I1 I2 M M2
8 � x 11 � 55,1 45,� 44 40 �6,� 158 184 9 4 x �0 4,� 6�,9 5�,9 51 47 4�,9 �10 ��5
1) With max. bore Standard voltage �4 VDC.�) Turning for RS-ball bearing according to order regulations – Permissible voltage tolerances to IEC �8 +/-10 %.
no turning is allowed for in the standard range. We reserve the right to make dimensional and design alterations.*) Please observe run-in regulations or minimum speed (see page �).
Order example:
8 – 9 without accessories .......0 with flange hub ...............1
Example: Order number 8/580.110/�4/40/40
according to size(only with flange hub)
according to size
�4 V-coil
Size N O S S1 s1 t1 W ZH8 z
8 9�,9 100,4 1�,5 � x 8,4 � x M10 8,5 15 100 4 9 116,8 117,8 1�,5 � x 8,4 4 x M1� 11,8 �0 1�5 4
Type 580.100Coil carrier with small hole circle
Type 580.110Coil carrier with small hole circle and flange hub
➤
➤➤
➤ ➤ ➤➤ ➤
➤
➤
➤
bore forscrew DIN 6912, 7984with spring ring DIN 7980
2)
ROBATIC® Electromagnetic Clutch
order number: 580.1_0
powertransmission
®
1�
With coil carrier in bearing Sizes 3 – 9 Type 540.100 540.102
Technical data and dimensions Nominal Max. Electrical Mass moment of inertia Weight torque *) speed power Iown [10-4 kgm2] G [kg] Armature Rotor 2) Without With Pilot Preferred disc accessories flange bores bores M2 n P20 hub Size [Nm] [rpm] [W] a D D1 d2 d2 max d2
H7
� 10 8000 18 0,�5 1,�7 0,7�� 0,78� 0,� 64,5 70 7 �01) 10, 15 4 �0 6000 19 1,05 �,�5 1,�� 1,�9 0,� 81,5 87 8 �51) 17, �0 5 45 5000 �8 �,97 9,�6 1,85 �,01 0,� 99 106 1� �0 �0, �5, �0 6 80 4�00 �8 7,04 �0,8 �,16 �,�8 0,� 118 1�5 1� 40 �0, �5, �0 7 160 �600 46 14 54,4 5,54 6,11 0,� 151 157 19 50 �5, �0, 40 8 ��0 �000 61 81 178,0 11,6 1�,86 0,5 19� �00 �� 60 40, 45, 50 9 640 ��00 8� �15 46�,0 ��,� ��,9� 0,5 �51 �51 �0 65 40, 50, 60
Size G K k L I6 M n1 O1 P p s1 t t1 UP9 u V Y Y1
� �9,5 � x 4,� 0,8 �8 40 46 9 44 70 64 � x M� �,8 4,1 6 � 0,05 45° �0° 4 �0,5 � x 4,6 1,7 �1 4�,5 60 9 48 79,7 7� � x M4 4,� 5,0 8 �,5 0,05 45° �0° 5 45,5 � x 5,8 1,0 �5,9 49 76 10 54,9 98,� 85 � x M5 5,7 6,9 8 �,5 0,05 �0° ��,5° 6 48 � x 7 1,0 40,5 55 95 10,5 6�,0 115,4 105 � x M6 6,7 6,7 10 �,5 0,05 �0° ��,5° 7 69 � x 9,4 �,0 46,5 61,5 1�0 1� 70,5 150,4 1�0 � x M8 8,7 8,� 1� � 0,1 �0° 15° 8 91 � x 11,5 �,0 55,4 74 158 1� 85,1 189,4 145 � x M10 10,6 8,5 14 4,5 0,1 �0° 15° 9 111 4 x �0 4,� 6�,9 81 �10 15,5 9�,9 ��5,8 150 4 x M1� 1�,4 11,8 14 6 0,1 �0° 15°
1) With max. bore keyway to DIN 6885/� Standard voltage �4 VDC.�) With max. bore Permissible voltage tolerances to IEC �8 +/-10 %.�) Connection dimensions for flange hub, see pages 10 and 11 We reserve the right to make dimensional and design alterations.*) Please observe run-in regulations or minimum speed (see page �).
Order example: To be included when ordering, size type voltage bore please state: [V DC] Ø d�
H7
order number: 540.1_ _� – 9 without accessories ........... 0 flange hub ......................... 1�) power cable ...................... 0terminal ............................. �
according to size
�4 V-coil
Type 540.100With coil carrier in bearing
Type 540.10�With coil carrier in bearing and terminal
➤
➤➤
➤➤
➤ ➤ ➤ ➤➤
➤
➤
Example: Order number 5/540.100/�4/�0
permissibleshaft misalignment
groove for
friction support
ROBATIC® Electromagnetic Clutch
powertransmission
®
14
With flange in bearing3) Sizes 3 – 9 Type 540.14_
Technical data and dimensions Nominal Max. Electrical Max. Max. Mass moment of inertia Weight torque speed power admissible admissible Iown[10-4 kgm2] with max. M2 P20 friction friction Rotor Armature bore work with PRperm with max. disc + Type **) an unique bore driving 540.140 switching WRperm Type flange Size [Nm] [rpm] [W] [J] [ J
sec] 540.140 [kg] a D1 D3 d3 d4max
� 10 8000 18 �,8x10� 67 1,59 1,97 1,� 0,� 70 71 16 15 4 �0 6000 19 6,�x10� 89 �,8� 4,06 1,85 0,� 87 8� �0 191)
5 45 5000 �8 9x10� 110 10,�4 9,95 �,95 0,� 106 10� �6 �4 6 80 4�00 �8 15x10� 1�5 ��,�� ��,9� 4,7 0,� 1�5 1�� �66)/�77) �� 7 160 �600 46 �5x10� 167 6�,05 50,5� 8,�5 0,� 157 156 �78)/479)_11) 46 8 ��0 �000 61 4�x10� ��� 197,66 174,8� 16,6 0,5 �00 199 �78)/479)/5911) 58 9 640 ��00 8� 65x10� �80 497 5��,7 �9,� 0,5 �51 �50 4710)/6711)/_1�) 65
Order example:
To be included when ordering, size type voltage bore *counterbore please state: [V DC] Ø d4 by choice
order number: 540.14 _ AS or AÜ
� – 9 power cable ............... 0terminal ....................... �
Example: Order number 5/540.140/�4/�4/AS
AS ... counterbore at coil carrier side
AÜ ...counterbore at transmission flange side
according to size
�4 V-coil
Type 540.140With flange in bearing
Key Size eh6 L L7 I3 I8 M3 n1 n3 O5 P p s2 UP9 u W1 X x Y1 Y2
� 56 �8 �5,8 �5 �1,5 66 9 16 70 70 64 �xM4 6 � 17,5 6x6x16 �,5 75° 90° 4 64 �1 �9,7 454)/�55) �4 75 9 17 78 79,7 7� �xM5 8 �,5 19 6x6x18 �,5 75° 90° 5 75 �5,9 �8,7 506)/407) �0 94 10 19 94 98,� 85 �xM5 8 �,5 �4,5 8x7x�� 4 5�,5° 90° 6 90 40,5 4�,5 606)/407)/�09) �4 11� 10,5 �1,5 106 115,4 105 �xM6 10 �,5 �8 10x8x�5 5 5�,5° 90° 7 110 45,5 48,9 558)/�59)/_11) �9 145 1� �4 1�0 150,4 1�0 �xM6 1� � �1 10x8x�8 5 45° 90° 8 1�5 55,4 5�,9 758)/559)/�511) 44 184 1� �0 140 189,4 145 �xM8 14 4,5 �6 14x9x�� 5,5 45° 90° 9 160 6�,9 57,1 7010)/4011)/_1�) 46 ��5 15,5 �0 15� ��5,8 150 �xM8 14 6 �8 16x10x�6 6 45° 1�5°1) Above Ø 18 keyway to DIN 6885/� with 4) Above Ø d4 to 14 9) Above Ø d4 over �8 Standard voltage �4 VDC. d4max - depth of hub keyway 1,�+0,1 5) Above Ø d4 over 14 10) Above Ø d4 to �8 Permissible voltage tolerances to�) �-shaft connection on request 6) Above Ø d4 to 19 11) Above Ø d4 over �8 IEC �8 +/- 10 %.**) Please observe run-in regulations or 7) Above Ø d4 over 19 1�) Above Ø d4 over 55 We reserve the right to make dimensional minimum speed (see page �). 8) Above Ø d4 to �8 and design alterations.
➤➤➤
➤ ➤ ➤➤ ➤
➤
➤
➤
➤
groove for key „x“
groove for
friction support
ROBATIC® Electromagnetic Clutch
powertransmission
®
15
Size 3 4 5 6 7 8 9
a 0,� +0,1 0,�+0,15 0,�+0,15 0,�+0,15 0,�+0,15 0,5+0,15 0,5+0,15 -0,05 -0,05 -0,05 -0,05 -0,05 -0,1 -0,1
e 0,�5 0,� 0,� 0,�5 0,5 0,55 0,6
Table for the adjustment of the air gaps Table concerning the admissible shaft displacement
Fig. 1 Fig. �
Size 3 4 5 6 7 8 9
V 0,05 0,05 0,05 0,05 0,1 0,1 0,1
Table 1
The dimension „a“ (Fig. 1) is to be adjusted according to the table 1. Care must be taken to ensure that the shaft is fastened axially, since, otherwise the dimension „a“ will change and cause the rotor to brush against the armature disc or the coil carrier. The air gap „e“ is chosen, that a banding of the rotor at the coil carrier is not possible when keeping the permissible center deviations V and V1 (see table technical data).
Construction:ROBATIC®-Electromagnetic clutches are manufactured to IP 54 specification and the insulation class F to 155 °C for coil, moulding compound and power cable as well as insulation class B 1�0 °C for the magnet coil plastic-extrusion-coated. The friction linings are asbestos free, the surface of coil carrier, rotor and flange hub are phosphated. The armature disc is nitrited and the transmitting spring is made of stainless steel. The drive elements should be made of magnetically poor transmitting material to avoid magnetic field losses and subsequent power reduction.
ROBATIC® clutches are used for dry running. The torque is transmitted by connection of the armature disc on the iron poles and friction lining of the rotor.
When coupling two shafts the eccentricity „V“ of the shafts according to table � must not be exceeded. The larger the displacement „V“ the greater the friction surface becomes. In the case of this arrangement care must be taken that both shafts have no axial play since, otherwise, a brushing of the rotor would also be possible. The flange hub is kept axially by means of a set screw (set at 90 ° to the key). The „V“-values are indicated again in the technical data of the individual clutches.
Table �
Please note:The running-in instructions or min. speed are to be observed (see page �, Section „Torque Characteristics“ and „Run-in Conditions").
The friction surfaces have to be absolutely free of oil and grease, otherwise, the torque drops significantly. The air gap „a“ (Fig. 1) has to be checked periodically. The clutch does not function correctly, if the max. working air gap is exceeded (see table 1, page 18).
Assembly and maintenance should be made by well trained specialists.
Technical Explanations
powertransmission
®
16
Designation
PA [kW] = drive power
MA [Nm] = drive torque
Ma [Nm] = acceleration torque of the clutch
Mreq. [Nm] = required torque
ML [Nm] = load torque (+ = drop load) (- = lift load)
MS [Nm] = switchable torque of the clutch (acc. to fig. 1, page 17)
n [rpm] = drive speed
K = safety factor >= �
I [kgm�] = mass moment of inertia
Iown. [kgm�] = mass moment of inertia (acc. to table of dimension)
Iadd. [kgm�] = additional mass moment of inertia
ta [sec] = acceleration time
tvM [sec] = braking time of the machine
t1 cl [sec] = switch-on time of the clutch } acc. to table 1,
t� cl [sec] = switch-off time of the clutch page 18
Sh max [h-1] = max. switching frequency per hour
(dependent on time)
Qtot. [J] = total friction work (acc. to table 1, page 18)
Qa [J] = total friction work per acceleration
QE [J] = perm. friction work with an unique switching }acc. to table 1,
Q1 [J/max] = friction work until 1 mm wear page 18
Zn = number of switchings until re-adjustment
Z = number of switchings until end of wear
a [mm] = nominal air gap } acc. to table 1,
an [mm] = max. working air gap page 18
Clutch size calculation
Formulae:
1. Drive torque
MA = 9550 · PA [Nm] n
�. Required torque
Mreq. ≥ K · MA [Nm]
�. Switchable torque of the clutch (acc. to fig. 1, page 17)
MS ≥ Mreq. [Nm]
4. Mass moment of inertia
I = Iown + Iadd. [kgm�]
5. Acceleration torque of the clutch
Ma = MS –(+) ML [Nm]
6. Acceleration time
ta = I · n + t1 cl [sec] 9,55 · Ma
7. Max. switching frequency per hour (dependent on time)
Sh max = 1 · �600 [h-1] tvM + (ta + t� cl) · 1,�
8. Friction work per acceleration
Qa = I · n� · Ms [J]
18�,4 Ma
9. Examination of the selected clutch size in fig. � (page 17, friction power diagram). Intersection friction work ÷ switching frequency must be below the friction power curve! If it is above, the next size has to be selected and re-calculated from point � on.
Qa < QE [J]
10. Number of switchings until adjustment
Zn = Q1 · (an - a) [-] Qa
11. Number of switchings until end of wear
Z = Qtot [-] Qa
Technical Explanations
powertransmission
®
17
Technical Explanations
Calculation example:Data
Input power PA = � kW
Input speed n = 1400 rpm
Load torque output ML = 15 Nm
Additional mass moment of inertia Iadd. = 0,15 kgm�
Braking time of the machine tv M = 1,5 [sec]
180 switchings per hour
Input torque
MA = 9550 · PA = 9550 · � = �0,5 [Nm] n 1400
Required torque
Mreq. = K · MA = � · �0,5 = 41 [Nm]
Determined clutch size (acc. to fig. 1) = size 6
MS ≥ Mreq. = 47 [Nm]
Selected clutch = size 6 type 500.�00.0
Mass moment of inertia
I = Iown + Iadd. = 0,001756 + 0,15 = 0,151756 [kgm�]
Acceleration torque of the clutch
Ma = MS – ML = 47 - 15 = �� [Nm]
Acceleration time of the clutch
ta = I · n + t1*Cl = 0,151756 · 1400
+ 0,15 = 0,845 [sec] 9,55 · Ma 9,55 · ��
* Switching times t1 Cl and t� Cl from table 1, page 18 = without overexcitation
Max. switching frequency per hour
Sh max = 1 · �600 tvM + (ta + t�*Cl) · 1,�
Sh max = 1 · �600 = 1�9� [h-1] 1,5 + (0,845 + 0,060) · 1,�
Friction work per acceleration
Qa = I · n� · Ms = 0,151756 · 1400�
· 47 = ��95 [J] < = QE 18�,4 Ma 18�,4 ��
Switching frequency acc. to fig. � = 180 switchings per hour = permissible
(The point of intersection determined in fig. � must be located in or under the characteristic of the selected clutch)
Number of switchings until adjustment
Zn = Q1 · (an - a) = 57 · 107
· (1,� - 0,�) = �14196 switchings Qa ��95
Number of switchings until wear limit
Z = Qtot = 100 · 107
= 4175�6 switchings Qa ��95
Fig. 1
Fig. �
Friction power diagramvalid for speed = 1500 rpm
Switching frequency Sh [h-1]
Qa
Sw
itch
ing
wo
rk [
J]*)
Sw
itch
able
to
rque
MS [N
m]
Switchable torque
Speed n [rpm]ca
lcul
atio
n ex
amp
le
calc
ulat
ion
exam
ple
Size 9
Size 8
Size 3
Size 4
Size 5Size 6
Size 7
Size 9
Size 8
Size 3
Size 4
Size 5
Size 6
Size 7
*) Friction surfaces have been run in
powertransmission
®
18
Clutch size 3 4 5 6 7 8 9
Without t11 cl 0,010 0,015 0,0�0 0,0�0 0,045 0,050 0,060 over- t1 cl 0,045 0,065 0,080 0,150 0,�00 0,�50 0,400
Switching Type excitation t� cl 0,01� 0,0�0 0,045 0,060 0,090 0,095 0,1�0
times
500.___._ With over- t11 cl 0,00� 0,005 0,007 0,010 0,015 0,0�0 0,0�5
[sec]
excitation t1 cl 0,0�5 0,0�5 0,040 0,075 0,100 0,170 0,��5
Without t11 cl 0,010 0,01� 0,01� 0,0�0 0,0�5 0,050 0,060 over- t1 cl 0,050 0,07� 0,11� 0,160 0,�00 0,�50 0,460
Switching Type excitation t� cl 0,014 0,0�0 0,0�0 0,050 0,075 0,095 0,1�0
times
540.___._
With over- t11 cl 0,004 0,005 0,006 0,010 0,01� 0,0�0 0,0�5
[sec] excitation t1 cl 0,0�4 0,0�5 0,056 0,080 0,100 0,170 0,��5
Permissible friction work with a single switching QE [J] �,8 · 10� 6,� · 10� 9 · 10� 15 · 10� �5 · 10� 4� · 10� 65 · 10�
Friction Type work up to 500.___._
1�,5 · 107 �0 · 107 �� · 107 57 · 107 100 · 107 105 · 107 170 · 107
1 mm wear Type Q1 [J/mm] 540.___
8,8 · 107 1�,4 · 107 �4 · 107 �6 · 107 60 · 107 105 · 107 170 · 107
Total friction
Type work 500.___._
1�,5 · 107 �5 · 107 50 · 107 100 · 107 �00 · 107 185 · 107 �40 · 107
Qtot [J] Type 540.___._
8 · 107 16 · 107 �5 · 107 68 · 107 1�5 · 107 185 · 107 �40 · 107
Nominal air gap a [mm] 0,� 0,� 0,� 0,� 0,� 0,5 0,5
Max. working air gap an [mm] 0,6 0,8 1,0 1,� 1,5 1,8 �,0
Switching times:The switching times given in table 1 have been determined by comprehensive series of tests. They are valid for switching on the D.C. side with nominal air gap and warm coil.
Deviations depend on the corresponding overall situation, environmental temperatures, release path and the type of rectification with which the corresponding clutch is operated.
Table 1
M� = nominal torque of the clutch ta = acceleration time t1 = connection time t� = slipping time ML = load torque of the drive t11 = deceleration time for connection t� = disconnection time
Fig. �
Wear values NoteWear values can only be recommended values due to the operating parameters as for example: sliding speed, pressure or temperature.
2
2
time
time
Exc
itat
ion
(vo
ltag
e)
Off
On
Technical Explanations
powertransmission
®
19
The positioning accuracyfor the whole service life
Exact positioning until limit of wearideal for positioning operations.
Large internal diameters of the magnetic coil bodiesTherefore large permissible shaft diameters and few magnetic field losses.
High torque securitydue to an optimised magnetic field and new design of the ROBA®-quick. Therefore higher capacities due to few magnetic field losses.
Short switching times/high switching frequency
Low noise
ROBA®-quick Electromagnetic Brakes
powertransmission
®
�0
FunctionROBA®-quick are „energise to engage“, electromagnetic pole face brakes. If a DC voltage is applied to the magnetic coil (1) a magnetic field is formed, and the armature disc (�) is attracted to the coil carrier with friction lining (4). The brake torque runs from the coil carrier (�) via friction lining (4), armature disc (�) and membrane transmitting spring (5) to the flange and the shaft.
If the magnetic coil is de-energised the membrane transmitting spring (5) draws the armature disc (�) back to the flange (6). The brake is released and the shaft (7) can run freely.
ROBA®-quickStandard Page 21
ROBA®-quickSmall mounting diameter Page 23
Technical explanations Page 24
Electrical accessories Page 37
wear, air gapmax.
wear, air gapmax.
previous electro-magneticbrakes
adjusting interval
adjusting intervalnumber of switchings
number of switchings
ROBA®-quick Electromagnetic Brakes
powertransmission
®
�1
Standard Sizes 3 – 7 Type 520.200.0 520.201.0 520.202.0
Technical data and dimensions Nominal Max. Electrical Mass moment of Weight Preferred torque Speed power inertia G [kg] bores *) Iown [10-4 kgm2] Flange Without With M2 n P20 Armature hub 2)+ accesso- flange Size [Nm] [rpm] [W] disc armature disc ries hub a b D D2 d1min d1max d1
H7
� 8,5 8600 1� 0,76 1,0� 0,�8 0,4� 0,� 4,5 7�,5 70 9 �0 17, �0 4 17 7000 �0 1,9� �,75 0,55 0,86 0,� 4 9� 88 1� �0 �0, �5 5 45 6100 �1 6,86 8,6� 1,�5 1,40 0,� 5,5 115 110 15 �5 1) �5, �0 6 80 5800 47 17,56 �4,66 1,88 �,�5 0,� 5,5 140 140 �0 45 �0, 40 7 160 4500 71 5�,86 70,6� �,5 7,5 0,� 7,5 177 170 �� 60 40, 50
Order example:
To be included when ordering, size type voltage bore please state: [V DC] Ø d1
H7 �)
order number: 5�0.�0 _.0� – 7 without accessories......0 flange hub ....................1 internal hub .................� �) indication only with flange hub design or internal hub.
Example: Order number 5/5�0.�0�.0/�4/�0
according to size
�4; 104 V-coils
Size G g Hh9 K k L1 L2 I1 I2 M M1 n2 O1 O2 s s1 t t1 V
� �6 �9,5 80 �x4,5 1,6 ��,1 �0 �,5 16 60 7� �,6 4�,1 �6,1 4 x 4,8 � x M4 �,9 5,� 0,05 4 49 44 100 �x5,5 1,7 �4,7 �� 4,� 17 76 90 �,� 46,7 �9,7 4 x 5,7 � x M5 4,5 7,� 0,05 5 57,5 47 1�5 �x6,6 1,7 �8,1 �8 5,� �� 95 11� 1,1 56,1 �4,1 4 x 6,8 � x M6 5,8 8,7 0,05 6 74 66 150 �x8,7 �,� �1,4 �� 6 �5 1�0 1�7 0,4 6�,4 �8,4 4 x 6,8 � x M8 7,1 8,0 0,05 7 95 84 190 �x8,8 �,7 �4,7 �6 7 �7 150 175 1,7 70,7 4�,7 4 x 9,� � x M8 8,� 9,7 0,10
1) Up to Ø �� keyway to DIN 6885/1, over Ø �� keyway to DIN 6885/� Standard voltages �4 VDC; 104 VDC.�) With max. bore Permissible voltage tolerances to IEC �8 +/-10 %.*) Please observe run-in regulations or minimum speed (see page �). We reserve the right to make dimensional and design alterations.
V1 W ZH8 z
0,1 5 4� �,5 0,15 5 5� 4,5 0,15 6 6� 5 0,15 8 80 6 0,�0 8 100 6
Type 5�0.�00.0Standard
Type 5�0.�01.0Standard with flange hub
Type 5�0.�0�.0Standard with internal hub
➤
➤➤➤
➤ ➤ ➤➤
➤
➤
cable length: 400 mmdisplacedto bores by 45°
rectifier
mains ~
ROBA®-quick Electromagnetic Brakes
powertransmission
®
��
Standard Sizes 8 – 9 Type 520.100 520.110 520.120
Technical data and dimensions Nominal Max. Electrical Mass moment of Weight torque speed power inertia G [kg] Preferred *) Iown [10-4 kgm2] bores Flange Without With M2 n P20 Armature hub 2)+ accesso- flange Size [Nm] [rpm] [W] disc armature disc ries hub a b D D2 d1 min d1 max d1
H7 f
8 ��0 �000 40 81 107 5,64 1�,9 0,5 16 19� 185 �4 60 40, 50 9� 9 640 ��00 77 �15 �81 6,90 15,6� 0,5 16 �51 �4� �7 80 50, 60 11�
Order example:
To be included when ordering, size type voltage bore please state: [V DC] Ø d1
H7 �)
order number: 5�0.1 _08 – 9 without accessories.....0flange hub ...................1 internal hub ................� �) indication only with flange hub design or internal hub.
Example: Order number 8/5�0.110/�4/40
according to size
�4 V-coil
�) With max. bore Standard voltage �4 VDC.*) Please observe run-in regulations or minimum speed (see page �). Permissible voltage tolerances to IEC �8 +/-10 %. We reserve the right to make dimensional and design alterations.
Size G g Hh9 K k L2 L6 I2 I4 I7 M M1 n2 O2 O3 s s1 t1 V
8 91 84 ��0 �x11,5 � 45,� 40,1 �6,� 5 �0 158 �15 0,8 86,4 50,1 4x9 �xM10 8,5 0,1 9 111 104 �90 4x�0 4,� 5�,9 47,9 4�,9 6 �5 �10 �70 1,0 101,8 58,9 4x11 4xM1� 11,8 0,1
V1 W ZH8 z
0,� 15 100 4 0,�5 �0 1�5 4
➤
➤➤➤
➤ ➤ ➤➤
➤
➤
Type 5�0.100Standard brake
Type 5�0.110Standard with flange hub
Type 5�0.1�0Standard with internal hub
Cable length
shaft misalignment
*) observe run-in instructions or minimum speed (see page �).
ROBA®-quick Electromagnetic Brakes
powertransmission
®
��
Small mounting diameter Sizes 3 – 7 Type 520.210.0 520.211.0 520.212.0
Technical data and dimensions Nominal Max. Electrical Mass moment of Weight torque speed power inertia G [kg] Preferred *) Iown [10-4 kgm2] bores Flange Without With M2 n P20 Armature hub 2)+ accesso- flange Size [Nm] [rpm] [W] disc armature disc ries hub a b D D2 d1 min d1 max d1
H7
� 8,5 8600 1� 0,7 0,8 0,�5 0,40 0,� 4,5 7�,5 55 9 17 10, 15 4 17 7000 �0 1,79 1,97 0,58 0,65 0,� 4 9� 70 10 �0 17, �0 5 45 6100 �1 6,�8 7,19 1,� 1,�5 0,� 5,5 115 88 1� �0 �0, �5 6 80 5800 47 15,77 17,54 1,80 �,0 0,� 5,5 140 110 15 �5 1) �5, �0 7 160 4500 71 48,1 55,� �,� �,85 0,� 7,5 177 140 �0 45 �0, 40
Size G g Hh9 K k L1 L2 I1 I2 M M1 n2 O1 O2 s s1 t t1 V
� �6 �7 80 �x�,5 1,6 ��,1 15 �,5 11,5 46 7� 8,5 �7,1 �5,6 4x4,8 �xM� �,9 4,0 0,05 4 49 �9,5 100 �x4,5 1,7 �4,6 �0 4,� 16 60 90 6,1 44,6 �8,6 4x5,7 �xM4 4,4 5,� 0,05 5 57,5 44 1�5 �x5,5 �,� �8,1 �� 5,� 17 76 11� 7,9 50,1 ��,1 4x6,8 �xM5 5,9 6,7 0,05 6 74 47 150 �x6,6 �,7 �0,9 �8 6 �� 95 1�7 5,5 58,9 �6,9 4x6,8 �xM6 6,6 8,7 0,05 7 95 66 190 �x8,8 �,7 �4,4 �� 7 �5 1�0 175 5,7 66,5 41,4 4x9,� �xM8 8,1 8,� 0,101) Up to Ø �� keyway to DIN 6885/1, above Ø �� keyway to DIN 6885/� Standard voltages �4 VDC; 104 VDC.�) With max. bore Permissible voltage tolerances to IEC �8 +/-10 %.*) Please observe run-in regulations or minimum speed (see page �). We reserve the right to make dimensional and design alterations.
V1 W ZH8 z
0,1 5 �5 � 0,15 5 4� �,5 0,15 6 5� � 0,15 8 6� �,5 0,�0 8 80 �,5
Order example:
To be included when ordering, size type voltage bore please state: [V DC] Ø d1
H7 �)
order number: 5�0.�1 _.0� – 7 without accessories...0 flange hub .................1 internal hub ..............� �) indication only with flange hub design or internal hub.
Example: Order number 5/5�0.�1�.0/�4/�5
according to size
�4; 104 V-coils
Type 5�0.�10.0Small mounting diameter
Type 5�0.�11.0Small mounting diameter and flange hub
Type 5�0.�1�.0Small mounting diameter and internal hub
➤
➤➤➤
➤ ➤ ➤➤
➤
➤
permissible shaft misalignment
cable length: 400 mmdisplacedto bores by 45° rectifier
mains ~
ROBA®-quick Electromagnetic Brakes
ROBATIC® Elektromagnetkupplungpowertransmission
®
�4
Mounting tolerances
Table for the adjustment of the air gaps Allowable shaft displacement
Fig. 1 Fig. �
Size 3 4 5 6 7 8 9
a 0,�+0,1 0,�+0,15 0,�+0,15 0,�+0,15 0,�+0,15 0,5+0,15 0,5+0,15 -0,05 -0,05 -0,05 -0,05 -0,05 -0,1 -0,1
Size 3 4 5 6 7 8 9
V 0,05 0,05 0,05 0,05 0,1 0,1 0,1
Table 1
The dimension „a“ (Fig. 1) is to be adjusted according to the table 1. Care must be taken to ensure that the shaft is fastened axially, since otherwise the dimension „a“ will change and cause the armature disc to band against coil carrier.
Construction:ROBA®-quick Electromagnetic brakes are manufactured to IP 54 specification and the insulation class F to 155 °C for coil, moulding compound and power cables as well as insulation class B 1�0 °C for the magnetic coil plastic extrusion-coated. The friction linings are asbestos free, the surface of coil carrier and flange hub are phosphated. The armature disc is nitrated and the membrane spring is made of stainless steel.
ROBA®-quick brakes are used for dry running. The torque is transmitted by friction between armature disc and the iron poles and friction lining surface of the coil carrier.
When braking the eccentricity „V“ according to table � must not be exceeded. The larger the displacement „V“ the more the torque decreases and the hotter the friction surface becomes. In the case of arrangement according to table � care must be taken that the coil carrier and shaft have no axial play, since otherwise a brushing of the coil carrier would be possible. The flange hub is kept axially by means of a set screw (set at 90° to the key). The „V“-values are indicated again in the technical data of the individual brakes.
Table �
Please note:The running-in instructions or min. speed are to be obser-ved (see page �, Section „Torque Characteristics“ and „Run-in Conditions").
The friction surfaces have to be absolutely free of oil and grease as otherwise the torque drops significantly. The air gap „a“ (Fig. 1) has to be checked periodically. The brake does not function correctly if the max. working air gap (see table 1, page �7) is exceeded.
Assembly and maintenance have to be made by well-trained specialists.
powertransmission
®
�5
Designation
PA [kW] = drive power
MA [Nm] = drive torque
Mreq. [Nm] = required torque
ML [Nm] = load torque (+ = drop load) (- = lift load)
MS [Nm] = switchable torque of the brake (acc. to fig. 1, page �7)
Mv [Nm] = deceleration torque of the brake
n [rpm] = drive speed
K = safety factor clutch >= �
I [kgm�] = mass moment of inertia
Iown [kgm�] = own mass moment of inertia (acc. to table of dimensions)
Iadd. [kgm�] = additional mass moment of inertia
tv [sec] = deceleration time
taM [sec] = acceleration time of the machine
t1 Br [sec] = switch-on time of the brake } acc. to table 1
t� Br [sec] = switch-off time of the brake page �7
Sh max [h-1] = max. switching frequency per hour (dependent on time)
Qtot. [J] = total friction work (acc. to table 1, page �7)
Qv [J] = friction work per deceleration
QE [J] = perm. friction work with an unique switching}acc. to table 1
Q1 [J/max] = friction work until 1 mm wear page �7
Zn = number of switchings until re-adjustment
Z = number of switchings until end of wear
a [mm] = nominal air gap }acc. to table 1
an [mm] = max. working air gap page �7
Brake size calculation
Formulae:
1. Drive torque
MA = 9550 · PA [Nm] n
�. Required torque
Mreq. ≥ K · MA [Nm]
�. Switchable torque of the brake (acc. to fig. 1, page �6)
MS ≥ Mreq. [Nm]
4. Mass moment of inertia
I = Iown. + Iadd. [kgm�]
5. Deceleration torque of the brake
Mv = MS –(+) ML [Nm]
6. Deceleration time
tv = I · n + t1 Br [sec] 9,55 · Mv
7. Max. switching frequency per hour (dependent on time)
Sh max = 1 · �600 [h-1] taM + (tv + t� Br) · 1,�
8. Friction work per deceleration
Qv = I · n� · Ms [J]
18�,4 Mv
9. Examination of the selected brake size in fig. � (page �6, friction power diagram). Intersection friction work ÷ switching frequency must be below the friction power curve! If it is above, the next size has to be selected and re-calculated from point � on.
Qv < QE [J]
10. Number of switchings until adjustment.
Zn = Q1 · (an - a) [-] Qa
11. Number of switchings until end of wear.
Z = Qtot [-] Qv
Technical Explanations
powertransmission
®
�6
Calculation example:Data
Input power PA = � kW
Input speed n = 1400 rpm
Load torque output ML = 15 Nm
Additional mass moment of inertia Iadd. = 0,15 kgm�
Acceleration time of the machine ta M = 1,5 [sec]
�50 switchings per hour
Input torque
MA = 9550 · PA = 9550 · � = �0,5 [Nm] n 1400
Required torque
Mreq. = K · MA = � · �0,5 = 41 [Nm]
Determined brake size (acc. to fig. 1) = size 6
MS ≥ Mreq. = 47 [Nm]
Selected brake = size 6 type 500.�00.0
Mass moment of inertia
I = Iown + Iadd. = 0,001756 + 0,15 = 0,151756 [kgm�]
Deceleration torque of the brake
Mv = MS + ML = 47 + 15 = 6� [Nm]
Deceleration time of the brake
tv = I · n + t1* Br = 0,151756 · 1400
+ 0,10 = 0,46 [sec] 9,55 · Mv 9,55 · 6�
* Switching times t1 Br and t� Br from table 1, page �7 = without overexcitation
Max. switching frequency per hour
Sh max = 1 · �600 taM + (tv + t�*Br) · 1,�
Sh max = 1 · �600 = 1695 [h-1] 1,5 + (0,46 + 0,060) · 1,�
Friction work per deceleration
Qv = I · n� · Ms = 0,151756 · 1400�
· 47 = 1��6 [J] < = QE 18�,4 Mv 18�,4 6�
* Switching frequency acc. to fig. � = �50 switchings per hour = permissible
(The point of intersection determined in fig. � must be located in or under the characteristic of the selected brake)
Number of switchings until adjustment
Zn = Q1 · (an - a) = 57 · 107
· (1,� - 0,�) = 415 048 switchings Qv 1��6
Number of switchings until wear limit
Z = Qtot = 100 · 107
= 809 061 switchings Qv 1��6
Friction power diagramvalid for speed = 1500 rpm
*Friction surfaces have been run in Fig. 1
Fig. �
*) S
wit
chab
le t
orq
ue M
S [
Nm
]
Switchable torque
Speed n [rpm]
Size 9
Size 8
Size 7
Size 6
Size 5
Size 4
Size 3
QV S
wit
chin
g w
ork
[J]
Switching frequency Sh [h-1]
Size 9
Size 8
Size 7
Size 6
Size 5
Size 4
Size 3
calc
ulat
ion
exam
ple
calc
ulat
ion
exam
ple
Technical Explanations
powertransmission
®
�7
Brake size 3 4 5 6 7 8 9
Without t11 Br 0,006 0,008 0,010 0,015 0,0�5 0,0�7 0,0�0 over- t1 Br 0,0�5 0,040 0,055 0,100 0,150 0,�45 0,��0
Switching Type excitation t� Br 0,010 0,018 0,0�0 0,060 0,090 0,100 0,140
times
5�0.___._ With over- t11 Br 0,00� 0,00� 0,004 0,006 0,008 0,010 0,015
[sec]
excitation t1 Br 0,0�0 0,0�� 0,0�0 0,050 0,075 0,1�0 0,165
Permissible friction work with a single switching QE [J] �,8 · 10� 6,� · 10� 9 · 10� 15 · 10� �5 · 10� 4� · 10� 65 · 10�
Friction work up to Type 1�,5 · 107 �0 · 107 �� · 107 57 · 107 100 · 107 105 · 107 170 · 107
1mm wear 5�0.___._
Q1 [J/mm]
Total friction Type work
5�0.___._ 1�,5 · 107 �5 · 107 50 · 107 100 · 107 �00 · 107 185 · 107 �40 · 107
Qtot [J]
Nominal air gap a [mm] 0,� 0,� 0,� 0,� 0,� 0,5 0,5
Max. working air gap an [mm] 0,6 0,8 1,0 1,� 1,5 1,8 �,0
Switching times:The switching times given in table 1 have been determined by comprehensive series of tests. They are valid for switching on the D.C. side with nominal air gap and warm coil.
Deviations depend on the corresponding overall situation, environmental temperatures, release path and the type of rectification with which the corresponding clutch is operated.
Table 1
M� = nominal torque of the brake tv = deceleration time t1 = connection time t� = slipping time ML = load torque of the drive t11 = deceleration time for connection t� = disconnection time
Fig. �
time t
time t
On
OffExc
itat
ion
(vo
ltag
e)
Wear values NoteWear values can only be recommended values due to the operating parameters as for example: sliding speed, pressure or temperature.
Technical Explanations
powertransmission
®
�8
Sealed
High radial shaft end loadsOversized bearings high radial loads of the
input and output shafts permissible.
The new clutch-brake module for positioning and cyclic operations Positioning accuracy for the
whole service life High switching frequency Maintenance-free during the
whole service life Less energy necessary and
environment-friendly
Accurate positioning Precise switching function until
the end of service life.Maintenance-free/no manual adjustment Constant switching behaviour, i.e. high
positioning accuracy and maintenance-free until the end of service life.
No downtime because of re-adjustment.
Low field los-ses high friction capacitiesLarger magnetic and friction surfaces (asbestos free) with the same dimensions due to the new technology of the clutch and brake.
Optimised electromagnetic effect, i.e. low field losses, faster switching behaviour, less heat build up and, therefore, constant stopping accuracy.
Quiet operation
Individual variations Without flange
With integral cast IEC-flange
With hollow shaft
Heat dissipationOptimized heat dissipation and large cooling ribs provide for:
Optimum operation temperature due to dissipation of the frictional heat.
Constant characteristic operation values.
Sturdy housingConsists of en bloc cast two part ribbed housing, in a flanged design with integral flanges.
Large housing rigidity guarantees dimensionally stability, even with loads not caused under regular conditions (for example weight load by persons).
ROBA®-takt Clutch-Brake Module
FunctionThe ROBAOBA®-takt clutch-brake module is an electro-magnetic clutch-brake aggregate. As the drive machine continuously runs through, the device produces cycle operation via alternating coupling and braking.
The ROBAOBA®-takt clutch-brake module guarantees high cycle numbers. Due to the completely enclosed construction Protection IP 55, conceived acc. VDE/IEC directives, the ROBA ROBAOBA®-takt clutch-brake module aggregate is ideal for all standardized motors and gearboxes. This means that many different installation locations are possible.
Due to the self-adjusting patented principle, the ROBAOBA®-takt clutch-brake module can be accurately positioned and is maintenance-free.
powertransmission
®
�9
ROBA®-takt Clutch-Brake Module
Structural Components
Further structural components are available on request
Technical explanations Page 34
Electronic accessories Page 37
OUTPUT INPUT BRAKE CLUTCH OUTPUT INPUT
without flange/ without flange/ Type-No.: 674.0_4.0
shaft shaft Page 30
without flange/ IEC-flange/ Type-No.: 674.0_5.0
shaft hollow shaft Page 31
IEC-flange/ without flange/ Type-No.: 675.0_4.0
shaft shaft Page 32
IEC-flange/ IEC-flange/ Type-No.: 675.0_5.0
shaft hollow shaft Page 33
6
6
66
powertransmission
®
�0
Type 674.0_4.0
Size A B B1 B2 c c1 dk6 f H H1 i k L L1 I r u
� 1�6 75 9� 114 19 �7 14 1 86 6� M5 1�,5 �00 1�8 �0 6,6 �
4 146 95 115 1�7 �� 46,5 19 1 94 80 M6 16 ��9 157 40 9 �
5 165 110 1�6 156 �8 57 �4 1 106 90 M8 19 �79 177 50 11 4
6 189 1�0 15� 179 �8 67 �8 1 1�1 100 M10 �� ��� �01 60 11 4
7 ��� 145 175 ��0 �� 89 �8 1 14� 1�� M1� �8 408 �46 80 14 5
Standard voltages �4 VDC; 104 VDC. Permissible voltage tolerances to IEC �8 +/-10 %. We reserve the right to make dimensional and design alterations.
Technical data and dimensions Nominal torque Electrical power Speed Weight Inertia I Clutch Brake Clutch Brake max. kg output [10-4 kgm2] M2 P20 P20 n Type Type Size [Nm] [W] [W] [rpm] 674.014.0 674.014.0
� 10 8,5 17 1� �600 �,9 �,5
4 �0 17 �5 �� �600 6,8 6,�7
5 45 45 �0 �0 �600 9,9 �1,5
6 80 80 44 45 �600 15,� 60,5
7 160 160 79 70 �600 �7,7 1�8
Order example: To be included when ordering, output input please state: size type voltage shaft shaft with
[V DC] Ø dk6 Ø dk6 switch gear
order number: 674.0_4.0 W W see pages �7-�8
� – 7 without feet ..............0 with feet....................1
according to table (special dimension on request)
�4; 104 V-coils
Example: Order number 5/674.014.0/�4V/W�4/W�4
➤
➤➤
➤ ➤ ➤ ➤➤
➤
➤
output brake side
input clutch side
ROBA®-takt
powertransmission
®
�1
Type 674.0_ _.0
Order example: To be included when ordering, output input please state: size type voltage shaft shaft with
[V DC] Ø dk6 Ø d1F8
switch gear
order number: 674.0__.0 W B see pages �7-�8
� – 7
without feet ............0 with feet .................1
according to table (special dimension on request)
�4; 104 V-coilsclutch side:
5 IEC-flange small6 IEC-flange largeExample: Order number 4/674.015.0/�4V/W19/B�4
Technical data and dimensions Nominal torque Electrical power Speed Weight Inertia Small or IEC-dimensions Clutch Brake Clutch Brake max. [kg] I large output IEC-flange [10-4 kgm2] to choice M2 P20 P20 n Type Type Size [Nm] [W] [W] [rpm] 674.014.0 674.014.0 D d1
F8 b+03+05
e1 f1
� 10 8,5 17 1� �600 �,9 �,5
IEC-small 140 11 95 115 �,5 IEC-large 160 14 110 1�0 4
4 �0 17 �5 �� �600 6,8 6,�7
IEC-small 160 14 110 1�0 4 IEC-large �00 19 1�0 165 4
5 45 45 �0 �0 �600 9,9 �1,5
IEC-small �00 19 1�0 165 4 IEC-large �00 �4 1�0 165 4
6 80 80 44 45 �600 15,� 60,5
IEC-small �00 �4 1�0 165 4 IEC-large �50 �8 180 �15 4,5
7 160 160 79 70 �600 �7,7 1�8
IEC-small �50 �8 180 �15 4,5 IEC-large �00 �8 ��0 �65 4,5
Small or IEC- large dimensions IEC-flange Size to choice H1
1) I1 s1 A B B1 c c1 dk6 f H H21) i k L L1 l p
�
IEC-small 70 �5 9 110 75 9� 19 11 14 1 86 6� M5 1�,5 170 1�9 �0 1�
IEC-large 80 �� 9
4
IEC-small 80 �� 9 1�6 95 115 �� 1�,5 19 1 94 80 M6 16 199 158 40 1�
IEC-large 100 4� 11
5
IEC-small 100 4� 11 140 110 1�6 �8 18 �4 1 106 90 M8 19 ��9 178 50 14
IEC-large 100 55 11
6
IEC-small 100 55 11 164 1�0 15� �8 18 �8 1 1�1 100 M10 �� �6� �0� 60 14
IEC-large 1�5 65 14
7
IEC-small 1�5 65 14 198 145 175 �� �1 �8 1 14� 1�� M1� �8 ��8 �47 80 �0
IEC-large 150 90 14
➤ ➤ ➤ ➤ ➤➤
➤
➤
➤➤
➤➤
➤
1) Note difference in height of feet on driver and driven sides Standard voltages �4 VDC; 104 VDC. Permissible voltage tolerances to IEC �8 +/-10 %. We reserve the right to make dimensional and design alterations.
r u
6,6 �
9 �
11 4
11 4
14 5
output brake side
input clutch side
ROBA®-takt
powertransmission
®
��
Type 67_.0_4.0
Technical data and dimensions
1) Note difference in height of feet on driver and driven sides Standard voltages �4 VDC; 104 VDC. Permissible voltage tolerances to IEC �8 +/-10 %. We reserve the right to make dimensional and design alterations.Order example: To be included when ordering, output input please state: size type voltage shaft shaft with
[V DC] Ø dk6 Ø d1 k6 switch gear
order number: 67_.0_4.0 W W see pages �7-�8
� – 7 brake side:IEC-flange small .......5 IEC-flange large........6 without feet ..............0 with feet ...................1
according to table (special dimension on request)
�4; 104 V-coils
Example: Order number 4/675.014.0/�4V/W14/W19
Small or IEC- large dimensions IEC-flange Size to choice k L I m s A B B1 c c1 d1 k6 f1 H H2
1) i1 k1 L1 l1
� IEC-small 10 19� �� � 9
110 75 9� 19 11 14 1 86 6� M5 1�,5 1�9 �0 IEC-large 1�,5 �00 �0 �,5 9
4 IEC-small 1�,5 ��9 �0 �,5 9
1�6 95 115 �� 1�,5 19 1 94 80 M6 16 158 40 IEC-large 16 ��9 40 �,5 11
5 IEC-small 16 �69 40 �,5 11
140 110 1�6 �8 18 �4 1 106 90 M8 19 178 50 IEC-large 19 �79 50 �,5 11
6 IEC-small 19 �1� 50 �,5 11
164 1�0 15� �8 18 �8 1 1�1 100 M10 �� �0� 60 IEC-large �� ��� 60 4 14
7 IEC-small �� �88 60 4 14
198 145 175 �� �1 �8 1 14� 1�� M1� �8 �47 80
IEC-large �8 408 80 4 14
➤
➤➤
➤ ➤
➤➤
➤ ➤ ➤➤
➤
➤
p r u
1� 6,6 �,5
1� 9 �
14 11 �
14 11 �
�0 14 4
Nominal torque Electrical power Speed Weight Inertia Small or IEC-dimensions Clutch Brake Clutch Brake max. [kg] I large output: IEC-flange [10-4 kgm2] to M2 P20 P20 n Type Type choice Size [Nm] [W] [W] [rpm] 674.014.0 674.014.0 D dk6 bj6 e f H1
1) i
� 10 8,5 17 1� �600 �,9 �,5
IEC-small 140 11 95 115 � 70 M4 IEC-large 160 14 110 1�0 �,5 80 M5
4 �0 17 �5 �� �600 6,8 6,�7
IEC-small 160 14 110 1�0 �,5 80 M5 IEC-large �00 19 1�0 165 �,5 100 M6
5 45 45 �0 �0 �600 9,9 �1,5
IEC-small �00 19 1�0 165 �,5 100 M6 IEC-large �00 �4 1�0 165 �,5 100 M8
6 80 80 44 45 �600 15,� 60,5
IEC-small �00 �4 1�0 165 �,5 100 M8 IEC-large �50 �8 180 �15 4 1�5 M10
7 160 160 79 70 �600 �7,7 1�8
IEC-small �50 �8 180 �15 4 1�5 M10 IEC-large �00 �8 ��0 �65 4 150 M1�
output brake side
input clutch side
ROBA®-takt
powertransmission
®
��
Type 67_.0__.0
1) Difference in height of feet depends on flange diameter Standard voltages �4 VDC; 104 VDC. Permissible voltage tolerances to IEC �8 +/-10 %. We reserve the right to make dimensional and design alterations.Order example:
To be included when ordering, output input please state: size type voltage shaft shaft with
[V DC] Ø dk6 Ø d1 F8
switch gear
order number: 67_.0__.0 W B see pages �7-�8
� – 7 brake side:IEC-flange small .......5 IEC-flange large........6 without feet ..............0 with feet ...................1
according to table (special dimension on request)
�4; 104 V-coilsclutch side:
5 IEC-flange small6 IEC-flange largeExample: Order number 7/675.015.0/�4V/W�8/B�8
Nominal torque Electrical power Speed Weight Inertia Small or IEC-dimensions Clutch Brake Clutch Brake max. [kg] I large output IEC-flange [10-4 kgm2] to M2 P20 P20 n Type Type choice Size [Nm] [W] [W] [rpm] 674.014.0 674.014.0 D dk6 d1
F8 bj6 b+0,3+0,5
e
� 10 8,5 17 1� �600 �,9 �,5
IEC-small 140 11 11 95 95 115 IEC-large 160 14 14 110 110 1�0
4 �0 17 �5 �� �600 6,8 6,�7
IEC-small 160 14 14 110 110 1�0 IEC-large �00 19 19 1�0 1�0 165
5 45 45 �0 �0 �600 9,9 �1,5
IEC-small �00 19 19 1�0 1�0 165 IEC-large �00 �4 �4 1�0 1�0 165
6 80 80 44 45 �600 15,� 60,5
IEC-small �00 �4 �4 1�0 1�0 165 IEC-large �50 �8 �8 180 180 �15
7 160 160 79 70 �600 �7,7 1�8
IEC-small �50 �8 �8 180 180 �15 IEC-large �00 �8 �8 ��0 ��0 �65
Technical data and dimensions
Small or IEC- large dimensions IEC-flange Size to choice f f1 H1
1) i k L I I1 m s A B B1 c c1 H L1
�
IEC-small � �,5 70 M4 10 16� �� �5 � 9 94 75 9� 19 11 86 140
IEC-large �,5 4 80 M5 1�,5 170 �0 �� �,5 9
4
IEC-small �,5 4 80 M5 1�,5 189 �0 �� �,5 9 106 95 115 �� 1�,5 94 159
IEC-large �,5 4 100 M6 16 199 40 4� �,5 11
5
IEC-small �,5 4 100 M6 16 �19 40 4� �,5 11 115 110 1�6 �8 18 106 179
IEC-large �,5 4 100 M8 19 ��9 50 55 �,5 11
6
IEC-small �,5 4 100 M8 19 �5� 50 55 �,5 11 1�9 1�0 15� �8 18 1�1 �0�
IEC-large 4 4,5 1�5 M10 �� �6� 60 65 4 14
7
IEC-small 4 4,5 1�5 M10 �� �08 60 65 4 14 166 145 175 �� �1 14� �48
IEC-large 4 4,5 150 M1� �8 ��8 80 90 4 14
p r u
1� 6,6 �
1� 9 �
14 11 4
14 11 4
�0 14 5
➤
➤➤
➤ ➤
➤➤
➤ ➤ ➤➤
➤
➤
➤
➤➤
output brake side
input clutch side
powertransmission
®
�4
Technical Explanations
AssemblyClutch Brake Unit with flange:The shafts, locating spigots and shoulders, bolt holes, PCD’s and flanges are to IEC standards.Input and output sides can be fitted with the corresponding flanges of motor, gear reducer or other transmission elements as shown in Fig. 1 without problems.
Fig. 1
Fitting of transmission elements:The drive elements are pushed onto the respective shafts and secured axially via an axial securing screw and washer, the shafts being drilled and tapped accordingly, as shown in Fig. �.
For the combination motor shaft - ROBA®-takt hollow shaft the motor shaft must slightly be greased to prevent frictional corrosion.
Extensive force or hammer blows can damage the bearings.
Radial loads acting on the shaft via the drive elements must not exceed the maximum allowable values (see heading „permissible shaft load“).
Should both radial and axial loads be present on the shaft, the permissible loads must be determined - please contact our engineers.
Permissible shaft loads
Fig. 4
The drive elements located on the shafts exert a radial load during operation which has to be absorbed by the bearings of the unit. The load is limited by the required life of the bearings and strength of the shaft, Table 1.
Table-1 max. permissible radial load Fmax limited due to the strength of the shaft, application of load midway along shaft.
The application of load is assumed to be midway along the shaft, determining the acceptable radial load. In case there are additional axial loads, an extensive calculation is necessary (please contact our sales offices).
The acceptable radial loads mentioned in Table � refer to a speed n = 1500 rpm and a bearing service life Lh = 10 000 hours.
ROBA®-takt size 3 4 5 6 7
Input shaft ��� 995 �150 �705 5�55 without IEC-flange
Output shaft ��� 1105 ���1 �950 6�11 without IEC-flange
Output shaft - - - - - small IEC-flange
Output shaft ��� 1105 ���1 �950 6�11 large IEC-flangemax
. per
mis
sib
le
rad
ial l
oad
Fm
ax [
N]
ROBA®-takt size 3 4 5 6 7
Input shaft 4�6 547 681 819 1149 without IEC-flange
Output shaft 788 105� 1484 1685 �861 without IEC-flange
Output shaft 840 11�4 1586 1785 �115 small IEC-flange
Output shaft 788 105� 1484 1685 �861 large IEC-flangeRad
ial l
oad
FN [
N]
Table � acceptable radial load FN with speed n = 1500 rpm, bearing service life Lh = 10 000 hours assuming load applied midway along shaft.
The permissible load F can be calculated with factor k for other speeds or bearing life. The factor k is determined from Fig. �.
Fig. �
F = k · FN <= Fmax [N]
F in N = Permissible radial load
k = Correction factor (Fig. �)
FN in N = Acceptable radial load at n = 1500 rpm and bearing service life Lh = 10 000 hours (Table �)
Fmax in N = Max. acceptable radial load, limited due to shaft strength (Table 1)Fig. �
corr
ectio
n fa
ctor
k [
– ]
speed n [rpm]
bearing servicelife in hours
powertransmission
®
�5
Technical Explanations
9. Examination of the selected unit size in Fig. 6 page �6 (friction power diagram). Counter friction work ÷ cycling frequency must be below the friction power curve! If it is above, the next size has to be selected and re-calculated from point � on.
10. Number of cycles until end of wear
Z = Qtot [-] Qa* (Qv) · �
*(Qa / Qv put in higher value)
Wear value Note Wear values can only be recommended values due to the operating parameters as for example: sliding speed, pressure or temperature.
DesignationPA [kW] = drive powerMA [Nm] = input torque (input side)Mreq. [Nm] = required torque
ML [Nm] = load torque (In case of a load reduce the value in the bracket)
MS [Nm] = switchable torque (acc. to Fig. 5, page �6)n [rpm] = input speed (input side)K = safety factor >= �I [kgm�] = mass moment of inertiaIown [kgm�] = own mass of inertia (acc. to table of dimensions)Iadd. [kgm�] = additional mass moment of inertia ta [sec] = acceleration time (input side)tv [sec] = braking time (output side)t1 Cl [sec] = switching time of the clutch } acc. to table �t1 Br [sec] = switching time of the brake page �6Sh max [h-1] = max. cycling frequency per hour (dependent on time) Qtot. [J] = total friction work (acc. to table �, page �6)Qa [J] = friction work per accelerationQE [J] = perm. friction work with one engagement}acc. to table �Qv [J] = friction work per delay page �6ts [s] = delay timesZ = number of cycles until end of service life
ROBA®-takt size calculation
Formulae:ML = constantMS = constant
1. Required torque
MA = 9550 · PA [Nm] n
Mreq. ≥ K · MA [Nm]
�. Pre-selection of the unit size acc. to Fig. 5 page �6
MS ≥ Mreq. [Nm]
�. Mass moment of inertia
I = Iown + Iadd. [kgm�]
4. Acceleration time (input side) (MA ≥ MS)
ta = I · n + t1 Cl [sec] 9,55 · (MS
– (+)ML)
5. Braking time (output side)
tv = I · n + t1 Br [sec] 9,55 · (MS
+(–)ML)
6. Max. cycling frequency per hour (dependent on time)
Sh max = 1 · �600 [h-1] (tv + ta) · 1,�
7. Friction work per acceleration
Qa = I · n� · MS [J]
18�,4 MS – (+)ML
Qa < QE [J]
8. Friction work per delay
Qv = I · n� · MS [J]
18�,4 MS +(–)ML
Qv < QE [J]
Calculation example:Data:
Drive motor PA = 0,75 kW
Drive speed n = 1400 rpm
Load torque output ML = �,0 Nm
Additional mass moment of inertia Iadd. = 0,004� kgm�
�000 cycles per hour
Mass moment of inertia
I = Iown + Iadd. = 6,�7 · 10-4 + 0,004� = 0,00484 [kgm�]
Acceleration time (input side) (MA ≥ MS)
ta = I · n + *t1 9,55 · (Ms (+–)ML)
ta = 0,00484 · 1400 + 0,065 = 0,15� sec 9,55 · (11 - �)
Drive torque
MA = 9550 · PA = 9550 · 0,75 = 5,1 [Nm] n 1400
Required torqueMreq. = K · MA = � · 5,1 = 10,� [Nm]
Determined unit size (acc. to Fig. 5) = size 4MS ≥ Mreq. = 11 [Nm]
Braking time (output side)
tv = I · n + *t1 9,55 · (MS (+–)ML)
tv = 0,00484 · 1400 + 0,040 = 0,091 sec 9,55 · (11 + �)
* switching times t1 Cl and t1 Br from Table � page �6 = without overexcitation
Max. cycling frequency per hour
Sh max = 1 · �600 = (tv + ta) · 1,�
Sh max = 1 · �600 = 1��00 h-1
(0,091 + 0,15�) · 1,�
Friction work per acceleration
Qa = I · n� · MS = 0,00484 · 1400�
· 11 = 71,5 J ⇒QE* 18�,4 MS – ML 18�,4 11 - �
Friction work per delay
Qv = I · n� · MS = 0,00484 · 1400�
· 11 = 40,9 J ⇒QE* 18�,4 MS + ML 18�,4 11 + �
Checking of the selected unit size in the friction power diagram (make up centre Qa or Qv to Sh).
* The point of intersection determined in Fig. 6 must be located in or under the characteristic of the selected unit.
Number of cycles until end of service life
Z = Qtot = 44 · 107
= �,08 · 106 cycles Qa· � 71,5 · �
powertransmission
®
�6
Technical Explanations
ROBA®-takt size 3 4 5 6 7
Switching Without t11 Cl 0,010 0,015 0,0�0 0,0�0 0,045
times over- t1 Cl 0,045 0,065 0,080 0,150 0,�00
[s] excitation t11 Br 0,006 0,008 0,010 0,015 0,0�5
t1 Br 0,0�5 0,040 0,055 0,100 0,150
t� Cl 0,01� 0,0�0 0,045 0,060 0,090
t� Br 0,010 0,018 0,0�0 0,060 0,090
With over- t11 Cl 0,00� 0,005 0,007 0,010 0,015
excitation t1 Cl 0,0�5 0,0�5 0,040 0,075 0,100
(only switch-on t11 Br 0,00� 0,00� 0,004 0,006 0,008
time) t1 Br 0,0�0 0,0�� 0,0�0 0,050 0,075
Recommended duration of overexcitation [ms] 0,010* 0,010* 0,010 0,015 0,0�0
Min. necessary With overexc. 0,0�0 0,0�5 0,0�0 0,080 0,1�0
delay time [ts] Without overexc. 0 0 0,015 0,050 0,080
Height of the overexcitation = approx. 10 x nominal voltage (current limited)
Permissible friction work with an unique cycling QE [J] �,8·10� 6,�·10� 9·10� 15·10� �5·10�
Total friction work Qtot. [J] ��,5·107 44·107 87·107 171·107 �40·107
Fig. 5*) Friction surfaces have been run in
Fig. 6
Friction power diagramThe point of intersection determined in Fig. 6 must be located in or under the characteristic of the selected unit.
Valid for speed≥ 1500 rpm
Switching times:The switching times given in table � have been determined by comprehensive series of tests. They are valid for switching on the D.C. side with warm coil.
Deviations depend on the corresponding overall situation, environmental temperatures and on the type of rectification with which the corresponding unit is operated.
M� = Characteristic torque of the clutch or brake
ML = Load torque of the driveta = Acceleration timetv = Deceleration timet1 = Connection timet11 = Delay time for connectiont� = Disconnection timet� = Slipping time
Table �
Fig. 7
Switchable torque
Speed N [rpm] Cycling frequency [h-1]
calc
ulat
ion
exam
ple
calculation example
Clutch
Clutch
Brake
Brake
Size 3
Size 4
Size 5
Size 6
Size 7
Size 7
* In case of operation with overexcitation and high switching frequency (80-100 % of the diagram value), the recommended period of the overexcitation acc. to table � must not be exceeded.
*) S
wit
chab
le t
orq
ue M
S [
Nm
]
Sw
itch
able
wo
rk [
L]
Switching delay time Br
Clutch
OFF
ON
ON
BrakeVolta
ge
Size 6Size 5
Size 4Size 3
Clutch Brake
Switching delay time Cl
time t
powertransmission
®
�7
Dimension (mm)
Order example:
To be stated on order: Size Type
Order number _ 0 1 4 . 000 . � ROBA®-takt control unitSizes �-7
▲
ROBA®-takt Control unit Type 014.000.2
Application
This unit is used to start, stop and to position by switching and controlling the mayr®-clutch-brake units.
Function
The ROBA®-takt control unit operates according to the principle of a clocked switching controller with a frequency of 18 kHz. Its coil is energised by actuating the sensor for clutch and brake. A temperature monitor protects the unit from overheating. Should the temperature exceed >80 °C, the coil voltage is switched off. The LED “excess temperature unit” lights up red.A slope separation avoids simultaneous occurrence of clutch and brake torques.On overexcitation, the coil attraction time is reduced, allowing exact switching and positioning.
Electrical Connection
PE, L1, N Connection input voltage+1�V / Ku/ Gnd1 Sensor connection for clutch+1�V / Br / Gnd� Sensor connection for brakeBr1 / Br� Coil connection for brakeKu1 / Ku� Coil connection for clutch
Technical Data
Input voltage ��0 VAC ±10 %, 50-60 HzCurrent consumption Max. 4 Amp./100 % duty cycleNo-load supply power < 7 WattCoilNOM-voltage �4 VDCCoilNOM-power Max. 96 WattCoilNOM-current Manufacturer-side setting to mayr®-ROBA®-takt-sizeCoil overexcitation Max. ��5 VDC current limitation is adapted to the respective coil sizeOverexcitation time �-50 ms (–�0 % up to +60 %), externally adjustable (only applicable with coding „overexcitation ON“)Slope separation �-150 ms (–�5 % to +�0 %),
externally adjustable Protection IP �0Ambient temperature 0 °C up to +50 °CStorage temperature -�0 °C up to +70 °CClamping conductor 0,14-�,5 mm� / AWG �6-14cross section Weight 1,5 kg / �,�1 lbProtection fuse Input-side G-microfuse F1/F�, 4 A (M), IEC 5x�0mmCoil-side G- microfuse F�, the current is adapted to the
ROBA®-takt sizes. Always use the same replacement fuses
Overvoltage category two; one for connection to PELV/SELV (control wires)
Overvoltage protection For installation in overvoltage categroy III, a suitable overvoltage protection unit is required between the incoming voltage and the ROBA®-takt control unit.
Control unit temperature monitoringA fitted temperature switch prevents the control unit fromoverheating.
powertransmission
®
�8
ROBA®-takt Control unit Type 014.000.2
Functional sequence
Connection Example
Control elements / control functionControl sensor for start and stop
Brake = (Br)Clutch = (Ku)
Application Function Function (condition-controlled) (slope-controlled)
Close contact Clutch ON Close contact Clutch ON clutch or Open contact Brake ON Close contact Brake ON brake
+�4 VDC signal Clutch ON +�4 VDC signal Clutch ON to clutch or 0 VDC signal Brake ON +�4 VDC signal Brake ON to brake
+10-�0 VDC signal Clutch ON +10-�0 VDC signal Clutch ON to clutch or 0 VDC signal Brake ON +10-�0 VDC signal Brake ON to brake
Sensor undamped Clutch ON Sensor clutch Clutch ON undamped or Sensor damped Brake ON Sensor brake Brake ON undamped
Sensor undamped Clutch ON Sensor clutch Clutch ON undamped or Sensor damped Brake ON Sensor brake Brake ON undamped
Connection example1-sensor operation
Connection example2-sensor operation
Contact potential-free(NO contact)
SPS control(10 up to 30 VDC)
External voltage(10 up to 30 VDC)
NAMURProximity switch (10 up to 30 VDC)
PNP – NC contactProximity switch(10 up to 30 VDC)
powertransmission
®
�9
Order example:
To be stated on order: Size Type
Order number _ 0 0 4 . 000 . _ 0 = only printed board without frame1 = printed board with mounting frame
▲
ROBA®-takt Circuit Module Type 004.000._
Application
This device is used to start and stop mayr® ROBA®-takt circuit modules and mayr®-clutch brake combinations.It can be used for alternating �4 VDC coil switching, if a �4 VDC power supply is available.
Function
1-sensor operation: – activated – clutch is energised – deactivated – brake is energised
The respective control of the clutch or brake is indicated via LED. The ROBA®-takt circuit module has no over-excitation function.
The brake has priority: The brake is energised independently of the sensor position when the �4 VDC power supply is switched on.The coil is energised with the �4 VDC power supply.
Slope separation: To avoid simultaneous clutch and braking torques, a slope separation of 0 - 100 ms between clutch and brake can be set, which acts according to the respective rise time and drop-out time of the coils (see switching time table). This adjustment is carried out via the potentiometers Ku = clutch (P�) and Br = brake (P1). The factory default setting is 0 ms.
Technical Data
Input voltage �4 VDC SELV/PELV ripple content ≤5%
Recommended fuse T 4AOutput voltage �4 VDCOutput power max. 79 WSlope separation 0 - 100 ms (factory default setting is 0 ms)Ambient temperature 0 °C - +70 °CStorage temperature -�0 °C - +85 °CConductor cross section 0,14 - 1,5 mm² / AWG �6-14Protection IP 00Design printed board with screw-on
attachment part or a mounting frame for �5 mm standard mounting rails.
Max. cycle frequencies: 45 °C 70 °Cup to 1 A / sizes � + 4 600 600 cycles / minapprox. � A / sizes 5 + 6 �40 180 cycles / minapprox. � A / size 7 1�0 75 cycles / min
Please Observe:Higher cycle frequencies will lead to ROBA®-takt circuit module overload and failure.
Electrical Connection (Terminals)
1 �4 VDC input voltage� GND input voltage�+4 brake5+6 clutch7 1� VDC control voltage for switches or sensors8+9 control inputs
Dimensions with Mounting Frame (mm)
18/0
4/20
07 IM
Worldwide representation powertransmission
®
your reliable partner
TaiwanGerman Tech Auto Co. Ltd.No. 58, Wu Chuan RoadWu-Ku Industrial ParkTaipei Hsien, TaiwanTel.: 02/22990237Fax: 02/[email protected]
IndiaNational EngineeringCompany (NENCO)J-225, M.I.D.C. BhosariPune 411026Tel.: 0202/7474529Fax: 0202/[email protected]
AustraliaTransmission Australia Pty. Ltd.22 Corporate Ave,3178 Rowville, VictoriaAustralienTel.: 039/755 4444Fax: 039/755 [email protected]
South AfricaTorque TransferPrivate Bag 9Elandsfontein 1406Tel.: 011/3458000Fax: 011/[email protected]
Machine Tool Applications in ChinaDTC. Co.Ltd., Block 5th, No. 1699, East Zhulu Road,201700 Shanghai, ChinaTel.: 021/59883978Fax: 021/[email protected]
Great BritainMayr Transmissions Ltd.Valley Road, Business ParkKeighley, BD21 4LZWest YorkshireTel.: 0 15 35/66 39 00Fax: 0 15 35/66 32 [email protected]
ItalyMayr Italia S.r.l.Viale Veneto, 335020 Saonara (PD)Tel.: 0 49/8 79 10 20Fax: 0 49/8 79 10 [email protected]
FranceMayr France S.A.Z.A.L. du MinopoleBP 1662160 Bully-Les-MinesTel.: 03.21.72.91.91Fax: [email protected]
USAMayr Corporation4 North StreetWaldwickNJ 07463Tel.: 2 01/4 45-72 10Fax: 2 01/4 45-80 [email protected]
SingaporeMayr Transmission (S)No. 8 Boon Lay Way Unit 03-06, TradeHub 21Singapore 609964 Tel.: 0065/65601230Fax: 0065/[email protected]
ChinaMayr Shanghai Room 608, No. 1277 West Zhongshan Road, Conch Building,200051 Shanghai, ChinaTel.: 021/62953138Fax: 021/[email protected]
KoreaMayr Korea60-11, Woongnam-DongROK ChangwonRep. of KoreaTel.: 055/262-4024Fax: 055/[email protected]
Headquarters Chr. MayrGmbH + Co. KGEichenstraße 187665 MauerstettenTel.: 49-83 41/8 04-241Fax: 49-83 41/[email protected]://www.mayr.de
SwitzerlandMayr Kupplungen AGTobeläckerstrasse 118212 Neuhausen am RheinfallTel.: 0 52/6 74 08 70Fax: 0 52/6 74 08 [email protected]
JapanSumitomo HI-PTC Sales Co., Ltd.3-5-8, Kandakaji-Cho, Chiyoda-KuTokyo J101-0045Tel.: 03/52563091Fax: 03/[email protected]
AustriaBenelux StatesBrazilCanadaCzech RepublicDenmarkFinlandGreece
HongkongHungaryIndonesiaIsraelMalaysiaNew ZealandNorwayPhilippines
PolandRomaniaRussiaSlovakiaSloveniaSpainSwedenThailand
Note: If a country is not shown, please refer to headquarters or our web site to be advised of the nearest responsible agent.
Turkey