25
1 ROADSIDE SAFETY & GUARDRAIL DESIGN

ROADSIDE SAFETY GUARDRAIL DESIGN - IN.gov SAFETY & GUARDRAIL DESIGN. 2 PRESENTATION ... Flare Ends Outside of Const. CZ

Embed Size (px)

Citation preview

1

ROADSIDE SAFETY &

GUARDRAIL DESIGN

2

PRESENTATION

ROADSIDE SAFETYClear Zone & Obstruction Free ZoneTreatment of Obstructions Construction CZ

GUARDRAIL DESIGNGR PlacementGR Design for 3R ProjectsGR at Large Structures

Design Exceptions Common Mistakes & OmissionsPractice Pointers

3

Clear Zone Concept

Space for Vehicles Run-off-the-Road to Gain ControlAmount of Obstruction-Free Area for Vehicle RecoveryLike “Airport Runway” - Free of ObstructionsPlace Roadside Hazards Away from Pavement

4

Clear Zone Applicability

New Construction & Reconstruction3R/Partial 4R on InterstatesDesirable for 3RCost Effectiveness of Corrective MeasuresClear Zone values are not absoluteCZ Outside R/W – Use R/WEngineering Judgment Provide Consistent CZLevel 2 Design Exception

5Figure 49-2A

Clear Zone Distances

Total ADT on 2-Lane RdwysDirectional ADT on Divided Highways.Compare CZ for Aux. Lane vs MainlineShow CZ on Typicals

6Figure 49-2C

Horizontal Curve Adjustments

CZ = K * CZtc cz

K = Fig. 49-2BCZ

7

Obstruction Free Zone Concept

3R ProjectsAmount of Obstruction-Free Area next to RdwyNot the same as CZ Provide CZ, if practicalOFZ Width Varies

Des Speed, Arterial/ Collector, ADT Provide Traversable DitchesLevel 2 Design Exception

8

Typical Obstructions

TreesRevetment Riprap Ditches Non-Traversable Culvert EndsNon-Traversable DitchesConcrete HeadwallsUtility poles Bodies of water, permanent water depth>2’

Non traversable castings

9

1) Remove or Redesign2) Relocate Outside of CZ3) Make Breakaway to Reduce Impact Severity4) Shield with Traffic Barrier5) Delineate if other Treatments not Practical

Treatment of Obstructions

10

Construction Roadside Safety

IDM 82-4.0 Traffic Control Roadside Safety Reduce Motorist’s Exposure to Potential HazardsMaximize SeparationMinimize Positive Protection Devices

Applies to all Project TypesAnalysis & Review required for each MOT Phase

Construction CZFig. 82-4B

11

Construction Roadside Safety

Temporary Traffic BarrierFlare Ends Outside of Const. CZAvoid Openings in BarriersAvoid using in Tapers. Provide Shy Line OffsetCheck Horizontal SSD thru Tapers/Transitions

Plan DetailsShow CZ on Typical MOT SectionsShow CZ Design SpeedAllowable Flare & Taper RatesSummarize Quantities for each Phase

Pavement Drop-offsPrefer to Close Lane3” Max Drop-off at End of DayTemp Wedge at 1:1 next to Lane

12

GR Lateral PlacementPlace as Far Away from EP as PossibleShy Line Offset - Fig 49-5F Evaluate Alternatives

Additional CostReduced Barrier length, MaintenanceAccident History

INDOT Std Revisions Under Review8’ posts Backfill Material - Cohesive soils not CAB

Pave Shldr to Face of GR if offset 2’ or lessIf GR offset > 2’, Addt’l 2’ Paved not req’d

Varies

13

GR at Curb Locations

Avoid using GR behind curbs Best to use Mountable CurbOffset GR to Shy Line OffsetGR at Face of Curb

Shy Line Offset

E.P

.

14

Barrier Deflection

Clearance Face of GR to Fixed ObjectBased on Dynamic Deflection of Barrier/GR INDOT Std Revisions 8’ posts & BackfillCheck for Fixed Objects and Drop-offs

15

GR Need Horizontal Curves

GRAPHICAL SOLUTION REQUIREDINVESTIGATE BOTH ALTERNATIVESUSE SHORTEST LENGTH OF NEED

16

GR Alternate Offset

Tapered GR Example

17

Non-Recoverable Slopes

Non-Recoverable Fill Slope

No Obstructions in Non-Recoverable Slope

Point of Hazard*

18

GR Design Non-Recoverable Slopes

Traversable Ditch Cross Section Preferred

Example GR Design with 3:1 Slopes

19

GR Design Non Recoverable Slopes

Example GR Design with 3:1 Slopes

20

GR at Large Structures

New Construction 70 MPH Des SpeedNew Alignment – Divided HwyPerpetuate CZ thru Structure

21

Drainage Structures

1’ to 5’ Cross PipesUse Safety Metal ESSkew > 10 Deg Use GBES

5.5’ and Larger – End Inside CZIf Cost Effective, provide Traversable ESDesirable Place GR at 12’ from EPUse Nested GR if Low Fill

5.5’ and Larger – End Outside CZDesirable Place GR on slope away from EP Desirable Place GR at 12’ from EP

Ditch InletsE-7 and F-7 Not Within CZ Use Pipe Catch BasinOther Type with less than 4” Protrusion

0

0

0

22

Level 2 DECZ and OFZProvide Brief RationaleAlternates Considered

Document to FileSubmit to Project ManagerDiscuss at Field Check Local Projects need LPA Sign-off

Design Exceptions

23

Incorrect CZ DistanceIncorrect CZ AdjustmentCZ Not Shown on Typical SectionsObstructions within OFZ or CZObstructions not Shielded or TraversableNon-Traversable DitchesDesign Exceptions Not Documented Using less than 100’ of Nested GR

Common Mistakes & Omissions

24

Perform CZ reviewPlot CZ/OFZ on Plans Provide Consistent CZDetermine if any obstructions within CZDetermine/Verify Corrective ActionDiscuss CZ/OFZ at Field ChecksDocument DeficienciesCheck MOT Plan and CZ

Practice Pointers

25

ROADSIDE SAFETY &

GUARDRAIL DESIGN