Upload
others
View
1
Download
0
Embed Size (px)
Citation preview
INSTALL A
RHEEM DOMESTIC HOT WATER
GAS SOLAR WATER SAVINGELECTRIC
AUSTRALIA’S FAVOURITE NAME IN HOT WATER
INST
ALL
AC
OM
ES O
N S
TEA
DY
, HO
T A
ND
ST
RO
NG
23
CO
NTE
NTS
RH
EEM
IS
AU
STR
ALI
A’S
FA
VOU
RIT
E N
AM
EIN
HO
T W
ATER
AN
D T
HE
NA
ME
AU
STR
ALI
AN
S H
AV
E T
RU
STED
FO
R G
ENER
ATIO
NS
YO
U’L
L B
E R
IGH
T W
ITH
RH
EE
M
No.
1 w
ith
Au
stra
lian
fam
ilies
. R
hee
m i
s A
ust
ralia
’s f
avou
rite
hot
wat
er s
yste
m…
an
d it
’s b
een
th
at w
ay s
ince
19
39,
wh
en R
hee
m s
tart
ed m
akin
g w
ater
hea
ters
in A
ust
ralia
.
Gen
erat
ion
s of
Au
stra
lian
fam
ilies
hav
e re
lied
on
Rh
eem
for
wat
er t
hat
is s
tead
y, h
ot a
nd
str
ong
!
RH
EE
M IS
EV
ER
YW
HE
RE
Th
ere
is a
n u
neq
ual
led
net
wor
k of
exp
erie
nce
d R
hee
m
serv
ice
agen
ts a
cros
s th
e co
un
try.
No
mat
ter
wh
ere
you
are
in A
ust
ralia
th
ere
is e
xper
t ad
vice
ava
ilab
le t
o en
sure
th
at
you
get
th
e R
hee
m s
olu
tion
th
at is
rig
ht
for
you
.
WE
HAV
E T
HE
RIG
HT
RH
EE
M F
OR
YO
UR
hee
m h
as t
he
mos
t ex
ten
sive
ran
ge o
f h
ot w
ater
sys
tem
s
avai
lab
le in
Au
stra
lia.
Sol
ar,
gas
or e
lect
ric
stor
age.
Con
tinu
ous
flow
or
hea
t p
um
p.
En
ergy
eff
icie
nt.
Rh
eem
has
a ra
nge
of
cap
acit
ies
and
siz
es ju
st r
igh
t fo
r ev
ery
situ
atio
n.
Sol
ar,
gas
or e
lect
ric.
C
ontin
uou
s flo
w,
heat
pum
p or
sto
rage
. R
heem
has
a
rang
e of
hot
wat
er s
olu
tions
fo
r ev
ery
situ
atio
n.
CO
NC
ONN
CO
NC
ONNN
TETETENN
TEN
TEN
TENN
TTSTSTSTSC
ON
TEN
TS
4.
Rhe
em S
olar
Hot
Wat
er
6.
Rhe
em H
eat
Pum
p H
ot W
ater
8.
Rhe
em E
lect
ric
Sto
rage
Hot
Wat
er
10.
Rhe
em G
as S
tora
ge H
ot W
ater
12.
Rhe
em C
ontin
uou
s F
low
Gas
Hot
Wat
er
13.
Rhe
em W
ater
Sta
r W
ater
Sav
ing
Sys
tem
14.
Pro
duct
Dat
a
CH
OO
SIN
G T
HE
RIG
HT
CA
PA
CIT
Y R
HE
EM
FO
R Y
OU
R H
OM
E
You
r R
hee
m w
ill b
e se
rvin
g yo
u f
or m
any
year
s so
it’s
imp
orta
nt
to c
hoo
se t
he
righ
t ca
pac
ity
to m
eet
you
r n
eed
s
bot
h n
ow a
nd
as
you
r fa
mily
gro
ws.
Fact
ors
to c
onsi
der
in d
eter
min
ing
your
hot
wat
er n
eeds
:
at o
nce
.
mor
e h
ot w
ater
th
an y
oun
g ch
ildre
n).
hot
wat
er a
t th
e sa
me
time.
You
r h
ot w
ater
sys
tem
nee
ds
will
be
infl
uen
ced
by
the
wat
er c
ond
itio
ns,
clim
ate
and
wat
er p
ress
ure
in
you
r re
gion
.
INST
ALL
AC
OM
ES O
N S
TEA
DY
, HO
T A
ND
ST
RO
NG
45
59
62
70
/1S
2
5
27
2
5
20
59
62
70
/2S
3
5
38
3
5
29
59
02
70
/1S
-G
25
2
7
25
2
05
90
27
0/2
S-G
3
5
38
3
5
29
59
12
70
/2S
2
6
27
2
6
20
59
12
70
/3S
2
9
30
2
9
23
59
12
70
/2T
29
3
0
29
2
45
91
27
0/3
T 3
2
31
3
2
27
53
12
60
/2N
PT
26
2
6
26
2
15
11
27
0/2
NP
T-G
3
9
40
3
9
32
51
13
40
/2N
PT-
G
39
4
1
39
3
25
11
43
0/3
NP
T-G
4
5
45
4
5
39
51
12
70
/2N
PT
30
3
0
30
2
55
11
27
0/2
NP
T 3
0
30
3
0
25
51
14
30
/3N
PT
40
4
2
40
3
3
52
H1
80
K/1
S-G
2
4
24
2
4
20
52
H3
00
K/2
S-G
3
5
37
3
5
28
52
H1
80
K/1
S
16
1
7
16
1
25
2H
30
0K
/2S
2
7
28
2
7
22
52
S1
60
/1N
PT-
G
25
2
4
25
2
15
2S
30
0/2
NP
T-G
3
8
39
3
8
32
52
S1
60
/1N
PT
15
1
6
15
1
15
2S
30
0/2
NP
T 2
8
28
2
8
22
Prem
ier®
Lol
ine
Prem
ier®
Hil
ine
Hil
ine®
Loli
ne
MO
DE
L
Zone
1
Zone
2
Zone
3
Zone
4
SOLA
RPE
0PLE
YEAR
WAR
RANT
Y
5 & 6
160-
410
SAVI
NG
UP TO ENER
GY80%
CAPA
CITY
LITR
E2,
31
2-7
SOLA
RPE
0PLE
YEAR
WAR
RANT
Y
5 & 6
160-
410
SAVI
NG
UP TO ENER
GY80%
CAPA
CITY
LITR
E2,
31
2-7
SO
LAR
TH
AT S
AVE
S
WH
Y R
HE
EM
SO
LA
R
Ene
rgy
effi
cien
t –
use
s u
p t
o 8
0%
less
en
ergy
th
an a
n
elec
tric
wat
er h
eate
r, s
avin
g yo
u m
oney
.1
Red
uces
car
bon
em
issi
ons
– so
lar
syst
ems
save
up
to
3.3
ton
nes
of
gree
nh
ouse
gas
em
issi
ons
ever
y ye
ar.4
Min
imis
e re
lian
ce o
n fo
ssil
fue
ls a
nd p
rote
ct y
ours
elf
agai
nst
futu
re e
nerg
y co
st i
ncre
ases
– t
ake
adva
nta
ge o
f
Au
stra
lia’s
ab
un
dan
t su
pp
ly o
f su
nlig
ht,
an
d r
edu
ce y
our
5
Com
plet
e ra
nge
– th
e R
heem
sol
ar r
ange
incl
udes
bot
h
split
, gr
ound
mou
nted
sys
tem
s an
d co
mpl
ete
roof
mou
nted
mod
els
in a
var
iety
of
cap
acit
ies
from
16
0 –
410
Lit
res.
All
wea
ther
pro
tect
ion
– R
hee
m P
rem
ier®
Lol
ine
seri
es
pre
ven
ts t
he
sola
r sy
stem
fro
m f
reez
ing,
or
over
hea
ting
du
rin
g w
eath
er e
xtre
mes
.
Boo
ster
opt
ions
– R
hee
m s
olar
sys
tem
s ar
e av
aila
ble
wit
h
elec
tric
or
gas
boo
stin
g, p
rovi
din
g h
ot w
ater
du
rin
g cl
oud
y
wea
ther
, or
at
nig
ht.
Eli
gibl
e fo
r re
bat
es &
inc
enti
ves
– R
ECs
and
bot
h F
eder
al
& S
tate
Gov
ern
men
t re
bat
es a
re a
vaila
ble
for
inst
allin
g
sola
r w
ater
hea
ting.
6
Sol
ar w
ater
hea
ters
com
e in
bot
h r
oof
and
gro
un
d m
oun
ted
syst
ems
to s
uit
var
iou
s ap
plic
atio
ns
wit
h a
ch
oice
of
eith
er
shin
e. T
her
e ar
e ev
en m
odel
s su
ited
to
par
ticu
larl
y co
ld a
reas
,
wh
ich
mea
n e
very
fam
ily c
an e
njo
y th
e b
enef
its
a so
lar
wat
er
hea
ter
has
to
offe
r.
RE
NE
WA
BLE
EN
ER
GY C
ER
TIFIC
ATE
S
to e
nco
ura
ge t
he
inst
alla
tion
of
sola
r w
ater
hea
ters
pro
vid
ed
un
der
a F
eder
al G
over
nm
ent
oper
ated
sch
eme.
Th
e ta
ble
on
the
righ
t sh
ows
the
nu
mb
er o
f R
ECs
that
th
e so
lar
mod
els
are
elig
ible
for
in e
ach
of
the
fou
r zo
nes
acr
oss
Au
stra
lia.
To c
laim
you
r R
EC e
ntit
lem
ent,
sim
ply
com
ple
te t
he
REC
Ass
ign
men
t fo
rm t
hat
can
be
dow
nlo
aded
fro
m t
he
Rh
eem
Sol
arS
aver
s w
ebsi
te w
ww
.rh
eem
sola
rsav
ers.
com
.au
.
Oth
er F
eder
al a
nd
Sta
te G
over
nm
ent
reb
ates
may
als
o ap
ply
.F
or m
odel
des
crip
tion
s se
e p
rod
uct
dat
a on
pag
e 14
.
RH
EEM
SO
LA
R
HO
T W
ATER
THE
RIG
HT
RH
EE
M F
OR
YO
U
GR
OU
ND
MO
UN
TED
SYS
TEM
S
RO
OF
MO
UN
TED
SYS
TEM
S
3. A
s th
e w
ater
ris
es
it
hea
ts u
p.
2. W
ater
en
ters
th
e
colle
ctor
her
e.
1. W
ater
is p
um
ped
u
p t
o th
e so
lar
co
llect
or.
5. H
eate
d w
ater
ente
rs t
he
tan
k
4. H
eate
d w
ater
ex
its t
he
co
llect
or
h
ere.
HO
W S
OL
AR
WO
RK
S
Sol
ar w
ater
hea
ters
wor
k b
y ab
sorb
ing
ener
gy f
rom
the
sun
’s r
ays
in t
he
roof
mou
nte
d s
olar
col
lect
ors
and
tran
sfer
rin
g th
is t
o h
eat
wat
er s
tore
d in
th
e ta
nk.
Gro
un
d
mou
nte
d s
yste
ms
rely
on
inb
uilt
pu
mp
s to
pu
sh t
he
wat
er
thro
ugh
th
e sy
stem
, w
her
eas
roof
mou
nte
d s
yste
ms
rely
on a
nat
ura
l ‘th
erm
osip
hon
’ eff
ect.
Typ
ical
ly w
ater
pas
ses
thro
ugh
ch
ann
els
in t
he
sola
r co
llect
or w
her
e th
e w
ater
is
hea
ted.
As
the
wat
er m
oves
ou
t of
th
e co
llect
or a
nd
into
the
tan
k, t
he
tan
k gr
adu
ally
get
s h
otte
r u
ntil
th
e w
ater
reac
hes
its
max
imu
m s
tore
d t
emp
erat
ure
.
Pre
mie
r® L
olin
e
the
cold
est
of c
limat
es.
exch
ange
tec
hn
olog
y, a
ssu
rin
g yo
u o
f re
liab
le s
olar
per
form
ance
in
an
y w
eath
er e
xtre
me.
or r
emot
e G
as b
oost
mod
els
avai
lab
le.
stru
ctu
ral l
oad
on
you
r ro
of.
Loline
effi
cien
tly a
bso
rb e
ner
gy f
rom
th
e su
n.
max
imis
e so
lar
gain
.
Pre
mie
r® H
ilin
e
exch
ange
des
ign
, en
suri
ng
relia
ble
op
erat
ion
in a
ny
clim
ate.
stee
l tan
k cy
lind
er.
inst
alla
tion
.
qu
alit
y ty
pes
.
Hilin
e®
con
trol
lers
.
the
sola
r co
llect
ors
and
into
th
e ta
nk
usi
ng
ener
gy a
bso
rbed
fro
m
the
sun
.
Mod
el N
um
ber
:5
912
70
/2S
Mod
el N
um
ber
: 51
13
40
/2N
PT
Mod
el N
um
ber
: 5
2H
30
0K
/2S
Mod
el N
um
ber
: 5
2S
30
0/2
NP
T
1. w
arm
air
ente
rs
2. co
oler a
ir ex
its
4. h
eat i
s tra
nsfe
rred
to
the w
ater
in th
e
hea
t pum
p m
odul
e
5. h
eate
d wa
ter
re
turn
s to
th
e tan
k
3. co
ol wa
ter
en
ters
from
th
e tan
k
INST
ALL
AC
OM
ES O
N S
TEA
DY
, HO
T A
ND
ST
RO
NG
67
SOLA
RRA
TING
8EF
FICI
ENCY
PEOP
LECA
PACI
TYLI
TRE
YEAR
WAR
RANT
Y9
531
0-32
530
0%2-
6R
HEEM
HEAT P
UM
PH
OT W
ATER
NE
XT
GE
NE
RAT
ION
SO
LAR
Trad
ition
ally
sol
ar w
ater
hea
ters
hav
e p
rove
n t
hem
selv
es
to b
e an
en
ergy
eff
icie
nt
ren
ewab
le w
ater
hea
ting
alte
rnat
ive
to g
as a
nd
ele
ctri
c sy
stem
s, a
nd
wh
ile s
olar
syst
ems
are
still
an
eff
icie
nt
way
to
hea
t w
ater
, h
eat
pu
mp
s sa
ve e
qu
ival
ent
amou
nts
of
ener
gy a
nd
gre
en
hou
se g
as e
mis
sion
s to
ele
ctri
c b
oost
ed s
olar
sys
tem
s.
HO
W A
HE
AT
PU
MP
WO
RK
S
Rh
eem
Hea
t P
um
ps
del
iver
hot
wat
er b
y ef
fici
ently
util
isin
g a
free
an
d a
bu
nd
ant
sou
rce
of e
ner
gy –
th
e
hea
t th
at is
in t
he
air
arou
nd
us.
Ref
rige
ran
t va
pou
r
com
pre
ssio
n t
ech
nol
ogy
enab
les
the
hea
t p
um
p t
o
inte
nsi
fy t
his
hea
t, w
hic
h is
use
d t
o p
rod
uce
hot
wat
er.
Rh
eem
Hea
t P
um
ps
are
mor
e ef
fici
ent
du
rin
g w
arm
er
mon
ths,
an
d w
ill o
per
ate
for
less
hou
rs d
uri
ng
the
day
than
in c
old
er m
onth
s of
th
e ye
ar.
See
illu
stra
tion
bel
ow.
THE
RIG
HT
RH
EE
M F
OR
YO
U
HD
i-31
0
60
ºC h
ot w
ater
in a
lmos
t
an in
stan
t.
reco
very
to
pro
vid
e al
l th
e h
ot
wat
er y
ou’ll
nee
d.
a st
and
ard
ou
tdoo
r el
ectr
ic
wat
er h
eate
r fo
otp
rin
t.
MP
i-S
erie
s
wel
l bel
ow t
he
fen
ce li
ne,
w
hic
h k
eep
s n
oise
aw
ay
from
win
dow
s.
qu
iete
r op
erat
ion
.
des
ign
allo
ws
for
easy
b
uy
and
inst
all.
stor
age
wat
er h
eate
r, f
eatu
rin
g co
mm
on c
onn
ecti
ons.
®
50
ºC t
emp
erat
ure
mod
els.
tr
opic
al c
limat
es.
MP
s-S
erie
s
sep
arat
ed b
y u
p t
o 4
met
res,
al
low
ing
you
to
inst
all t
he
ta
nk
insi
de
a ga
rage
or
la
un
dry
sp
ace.
wal
l or
slab
mou
ntin
g to
mak
e th
e b
est
use
of
avai
lab
le s
pac
e.
envi
ron
men
tally
res
pon
sib
le,
as t
her
e is
no
risk
of
refr
iger
ant
esca
pin
g fr
om t
hem
.
tr
opic
al c
limat
es.
Wor
ks d
ay a
nd
nig
ht,
as t
hey
don
’t re
ly o
n
day
ligh
t to
op
erat
e.
Mod
el N
um
ber
: 5
5131
0
Mod
el N
um
ber
: 5
513
25
Mod
el N
um
ber
: 5
61
32
5
HD
i-3
10
2
8
24
2
8
27
MP
i-3
25
2
7
21
2
7
27
MP
s-3
25
2
8
23
2
8
28
MO
DE
L
Zone
1
Zone
2
Zone
3
Zone
4
Wh
en p
ower
is a
vaila
ble
, th
e H
eat
Pu
mp
hea
ting
cycl
e w
ill
con
tinu
e u
ntil
th
e ta
nk
is f
ull
of h
ot w
ater
.
WH
Y R
HE
EM
HE
AT
PU
MP
?
Ene
rgy
effi
cien
t –
cuts
en
ergy
use
an
d g
reen
hou
se g
as
emis
sion
s b
y u
p t
o 6
5%
.10
No
sola
r co
llec
tors
– r
edu
ces
stru
ctu
ral l
oad
on
you
r ro
of,
can
be
use
d w
her
e ro
of c
olle
ctor
s ar
en’t
su
itab
le.
Rep
lace
men
t fo
r el
ectr
ic w
ater
hea
ters
– u
ses
the
sam
e
plu
mb
ing
and
ele
ctri
cal c
onn
ecti
ons
as a
n e
lect
ric
wat
er
hea
ter,
mak
ing
it an
idea
l up
grad
e fr
om a
sta
nd
ard
ele
ctri
c
wat
er h
eate
r.
2 p
iece
des
ign
– re
sult
s in
a r
edu
ced
han
dlin
g w
eigh
t, m
akin
g
it ea
sy t
o d
eliv
er a
nd
inst
all o
n s
ite.
Eas
y to
ins
tall
– c
an b
e fu
lly in
stal
led
by
plu
mb
ing
trad
es.
Bac
k up
ele
men
t fi
tted
in
ever
y m
odel
– d
eliv
ers
hot
wat
er
even
on
th
e co
ldes
t of
win
ter
nig
hts
.
Eli
gibl
e fo
r re
bate
s an
d in
cent
ives
– R
hee
m H
eat
Pu
mp
s ar
e
Fed
eral
an
d S
tate
Gov
ern
men
t R
ebat
es.11
Whe
n su
itab
le,
prod
uct
can
be
conn
ecte
d to
low
er c
ost
tari
ff –
wh
ich h
elp
s re
du
ce r
un
nin
g co
sts.
8,
12
5 y
ear
war
rant
y.9
RE
NE
WA
BLE
EN
ER
GY C
ER
TIFIC
ATE
S
to e
nco
ura
ge t
he
inst
alla
tion
of
sola
r w
ater
hea
ters
pro
vid
ed
un
der
a F
eder
al G
over
nm
ent
oper
ated
sch
eme.
Th
e ta
ble
bel
ow s
how
s th
e n
um
ber
of
REC
s th
at t
he
sola
r m
odel
s ar
e
elig
ible
for
in e
ach
of
the
fou
r zo
nes
acr
oss
Au
stra
lia.
To c
laim
you
r R
EC e
ntit
lem
ent,
sim
ply
com
ple
te t
he
REC
Ass
ign
men
t fo
rm t
hat
can
be
dow
nlo
aded
fro
m t
he
Rh
eem
Sol
arS
aver
s w
ebsi
te w
ww
.rh
eem
sola
rsav
ers.
com
.au
.
Oth
er F
eder
al a
nd
Sta
te G
over
nm
ent
reb
ates
may
als
o ap
ply
.
INST
ALL
AC
OM
ES O
N S
TEA
DY
, HO
T A
ND
ST
RO
NG
89
RHEE
M O
PTIM
A®
2550
125
--
-
-1
2-3
80 - 1-2
160
250
400
5-9
315
4-6
3-5
2-4
4-6
2-4
1-3
-
Mod
el (L
itres
)16
025
040
0
PPH*
– O
ff-pe
ak ta
riff
5-9
315
4-6
3-5
2-4
4-7
3-4
2-3
1-3
PPH*
– C
ontin
uous
tarif
f
* Pe
ople
per
hou
seho
ld
PPH*
– O
ff-pe
ak ta
riff
PPH*
– C
ontin
uous
tarif
f
PPH*
– O
ff-pe
ak ta
riff
PPH*
– C
ontin
uous
tarif
f
Twin
ele
men
t
Mod
el (L
itres
)Si
ngle
ele
men
t
Mod
el (L
itres
)Si
ngle
ele
men
t
Mod
el (L
itres
)25
031
540
0
PPH*
– O
ff pe
ak ta
riff
Sing
le /
Twin
ele
men
t1-
3 / 2
-32-
4 / 3
-44-
6 / 4
-7
3-5
4-6
5-9
PPH*
– C
ontin
uous
tarif
fSi
ngle
/ Tw
in e
lem
ent
RHEE
MGL
AS® A
ND R
HEEM
PLUS
®
YEAR
WAR
RANT
YPE
OPLE
LITR
ECA
PACI
TY
25- 4
005
or 10
1-9
ELEC
TRIC
13, 1
4
RH
EEM
ELEC
TR
IC S
TO
RA
GE
HO
T W
ATER
MA
INS
PR
ES
SU
RE
HO
T W
ATE
R
Ele
ctri
c st
orag
e sy
stem
s
are
a re
lativ
ely
inex
pen
sive
solu
tion
to
you
r h
ot
wat
er n
eed
s.
RH
EE
M O
PTI
MA
® E
LEC
TRIC
14
cap
acit
ies
ener
gy t
arif
fs
mod
els
avai
lab
le
RH
EE
MG
LA
S® E
LEC
TRIC
13
160
L, 2
50
L, 3
15L
& 4
00
L
cap
acit
ies
mod
els
avai
lab
le
RH
EE
MP
LUS
® E
LEC
TRIC
13
tem
per
atu
re d
eliv
ery15
315
L ca
pac
itie
s
THE
RIG
HT
RH
EE
M F
OR
YO
U
Rh
eem
Ele
ctri
c S
tora
ge W
ater
Hea
ters
are
idea
l for
avai
lab
le in
a r
ange
of
cap
acit
ies
to s
uit
mos
t n
eed
s.
Bes
t of
all,
Rh
eem
Ele
ctri
c S
tora
ge W
ater
Hea
ters
com
e
wit
h t
he
Rh
eem
Mai
ns
Pre
ssu
re A
dva
nta
ge b
uilt
in.
Rh
eem
Mai
ns
Pre
ssu
re w
ater
hea
ters
hea
t w
ater
an
d s
tore
it so
th
at it
’s r
ead
y as
soo
n a
s yo
u n
eed
it.
Th
is e
nsu
res
full
pre
ssu
re t
o m
ulti
ple
ou
tlets
all
at t
he
sam
e tim
e.
WH
Y R
HE
EM
ELE
CTR
IC S
TOR
AG
E?
Des
igne
d fo
r A
ustr
alia
’s t
ough
con
diti
ons,
usi
ng
over
70
yea
rs o
f ex
per
ien
ce in
Au
stra
lia.
Idea
l fo
r us
e w
ith
econ
omic
al o
ff-p
eak
ener
gy t
arif
fs.
5 o
r 10
yea
r w
arra
nty
mod
els
avai
lab
le.1
3,1
4
Siz
es t
o su
it e
very
fam
ily
size
an
d h
ot w
ater
req
uir
emen
t
star
ting
from
25
L.
Mai
ns P
ress
ure
wat
er d
eliv
ery
for
stea
dy,
hot
an
d s
tron
g
hot
wat
er.
Indo
or m
odel
s av
aila
ble.
Full
tec
hnic
al s
uppor
t th
rou
gh R
hee
m’s
Nat
ion
al
Ser
vice
Net
wor
k.
OFF
-PE
AK
OR
CO
NTI
NU
OU
S E
LEC
TRIC
ITY?
Rh
eem
ele
ctri
c st
orag
e h
ot w
ater
sys
tem
s ar
e su
itab
le f
or
opp
osit
e fo
r co
mp
aris
on).
avai
lab
le t
o yo
u a
nd
use
s el
ectr
icit
y to
hea
t yo
ur
wat
er
over
nig
ht
du
rin
g lo
w d
eman
d, ‘o
ff p
eak’
tim
es.
On
ce h
eate
d,
the
wat
er is
th
en s
tore
d in
you
r in
sula
ted
tan
k fo
r u
se d
uri
ng
wat
er s
yste
ms
wit
h a
16
0 L
itre
cap
acit
y or
gre
ater
, d
epen
din
g
Sou
th A
ust
ralia
).
Con
tinu
ous
elec
tric
ity
is w
her
e p
ower
is a
vaila
ble
to
hea
t th
e
wat
er 2
4 h
ours
per
day
. A
sm
alle
r ta
nk
can
oft
en b
e u
sed
bu
t
the
run
nin
g co
sts
will
be
hig
her
.
Con
sult
you
r en
ergy
pro
vid
er f
or m
ore
info
rmat
ion
on
tar
iff
arra
nge
men
ts a
nd
cos
t co
mp
aris
ons.
CH
OO
SIN
G T
HE
RIG
HT
CA
PA
CIT
Y R
HE
EM
FO
R Y
OU
R H
OM
E
You
r R
hee
m w
ill b
e se
rvin
g yo
u f
or m
any
year
s so
it’s
imp
orta
nt
to c
hoo
se t
he
righ
t ca
pac
ity
to m
eet
you
r n
eed
s
bot
h n
ow a
nd
as
you
r fa
mily
gro
ws.
Fact
ors
to c
onsi
der
in d
eter
min
ing
your
hot
wat
er n
eeds
:
at o
nce
.
mor
e h
ot w
ater
th
an y
oun
g ch
ildre
n).
hot
wat
er a
t th
e sa
me
time.
You
r n
eed
s m
ay a
lso
dep
end
on
th
e cl
imat
e an
d
wat
er p
ress
ure
.
Mod
el N
um
ber
: 4
62
Ser
ies
Mod
el N
um
ber
: 11
1 S
erie
s
Mod
el N
um
ber
: 1
21
Ser
ies
10
11
INST
ALL
AC
OM
ES O
N S
TEA
DY
, HO
T A
ND
ST
RO
NG
GAS
RATI
NGEN
ERGY
PEOP
LEYE
ARW
ARRA
NTY
5, 7 o
r 10
2-6
4 or 5
PRES
SURE
MAIN
S17
, 18,
19
RH
EEM
GA
S S
TO
RA
GE
HO
T W
ATER
MA
INS
PR
ES
SU
RE
HO
T W
ATE
RW
HE
N Y
OU
NE
ED
IT
Mai
ns
pre
ssu
re g
as s
tora
ge w
ater
hea
ters
del
iver
hot
wat
er in
stan
tly,
as t
hey
kee
p a
gen
erou
s q
uan
tity
stor
ed
hot
an
d r
ead
y fo
r yo
ur
use
. A
s th
ey a
re a
t m
ain
s p
ress
ure
,
you
can
be
sure
of
a st
ron
g fl
ow o
f h
ot w
ater
, an
d t
he
abili
ty t
o se
rvic
e m
ult
iple
sh
ower
s or
hot
wat
er n
eed
s
at o
nce
. A
ch
oice
of
4 a
nd
5 S
tar
mod
els,
in a
ran
ge o
f
cap
acit
ies
mea
ns
ther
e is
a m
odel
for
eve
ry b
ud
get
and
fam
ily.
An
d s
hou
ld y
ou e
ver
run
sh
ort,
Rh
eem
’s h
igh
reco
very
mod
els
will
hav
e yo
u b
ack
in h
ot w
ater
fas
t.
FAC
TOR
S T
O C
ON
SID
ER
:
Pur
chas
e, I
nsta
llat
ion
and
Run
ning
cos
ts:
solu
tion
to
you
r h
ot w
ater
nee
ds.
Th
ere
is a
Rh
eem
mod
el t
o su
it ju
st a
bou
t ev
ery
bu
dge
t. I
f re
pla
cin
g an
exis
ting
gas
un
it,
ther
e is
pro
bab
ly a
Rh
eem
mod
el
wh
ich
can
sim
ply
be
inst
alle
d in
th
e sa
me
spac
e.
rep
rese
nts
ap
pro
x 7%
less
gas
usa
ge,
wh
ich
mea
ns
savi
ngs
in e
ner
gy b
ills.
16
Cap
acit
y:
can
be
fully
reh
eate
d in
on
e h
our;
th
e h
igh
er t
his
rat
e
the
fast
er y
ou c
an b
e b
ack
in h
ot w
ater
.
THE
RIG
HT
SIZ
E F
OR
YO
UR
NE
ED
S:
You
r R
hee
m s
yste
m w
ill b
e se
rvin
g yo
u f
or m
any
year
s
so c
hoo
se t
he
righ
t sy
stem
to
mee
t yo
ur
hot
wat
er n
eed
s
bot
h n
ow a
nd
in t
he
futu
re:
You
r n
eed
s m
ay a
lso
dep
end
on
th
e cl
imat
e an
d
wat
er p
ress
ure
.
WH
Y R
HE
EM
GA
S S
TOR
AG
E?
5 S
tar
ener
gy r
atin
g m
odel
s sa
ve y
ou m
oney
an
d a
re g
ood
for
the
envi
ron
men
t.
Des
igne
d fo
r A
ustr
alia
’s t
ough
con
diti
ons,
usi
ng
70
yea
rs
of e
xper
ien
ce in
Au
stra
lia.
5,
7 o
r 10
yea
r w
arra
nty
mod
els
avai
lab
le.17
, 1
8,
19
.
Cap
acit
ies
to s
uit
mos
t fa
mil
y si
zes
and
hot
wat
er
req
uir
emen
t, s
tart
ing
from
90
Lit
res.
Fast
hot
wat
er r
ecov
ery
of u
p t
o 2
00
Lit
res
per
hou
r av
aila
ble
.16
Hig
h re
cove
ry R
heem
Ste
llar
mod
els
inst
alla
tion
s.
Mai
ns p
ress
ure
wat
er d
eliv
ery
for
stea
dy,
hot
an
d s
tron
g
hot
wat
er.
Indo
or m
odel
s
The
abili
ty t
o se
rvic
e m
ulti
ple
uses
at
once
wit
hou
t
losi
ng
hot
wat
er p
ress
ure
.
Full
tec
hnic
al s
uppor
t th
rou
gh R
hee
m’s
Nat
ion
al
Ser
vice
Net
wor
k.
Ava
ilab
le t
o su
it N
atur
al G
as o
r P
ropan
e.
THE
RIG
HT
RH
EE
M F
OR
YO
U
RH
EE
M 5
STA
R
h
ot w
ater
16
17
RH
EE
MP
LUS
®
Ava
ilab
le in
Rh
eem
Plu
s® 5
0ºC
te
mp
erat
ure
mod
els
No
tem
per
ing
valv
e re
qu
ired
RH
EE
M 4
STA
R+ 1
8
+ O
nly
ava
ilab
le in
NS
W
RH
EE
M 3
STA
R#
17
#N
ot a
vaila
ble
in N
SW
RH
EE
M S
TELL
AR
®
16
h
ot w
ater
16
19
an
y h
ome
5 S
tar
ener
gy e
ffic
ien
t
Rh
eem
Gas
Sto
rage
wat
er
hea
ters
are
goo
d f
or t
he
envi
ron
men
t.
Mod
el N
um
ber
: 8
50
36
0
Mod
el N
um
ber
: 3
50
29
5
Mod
el N
um
ber
: 3
4717
0
Mod
el N
um
ber
: 31
117
0
INST
ALL
AC
OM
ES O
N S
TEA
DY
, HO
T A
ND
ST
RO
NG
12
13
GAS
RATI
NGEN
ERGY
PEOP
LECA
PACI
TYL/
MIN
YEAR
WAR
RANT
Y
1012
- 54
522
1-6
RH
EEM
CO
NTIN
UO
US
FLO
W G
AS
H
OT W
ATER
CO
NT
INU
OU
S H
OT
WAT
ER
WH
EN
YO
U N
EE
D I
T
Con
tinu
ous
Flo
w g
as w
ater
hea
ters
del
iver
hot
wat
er t
hat
will
nev
er r
un
ou
t b
ecau
se t
hey
hea
t w
ater
wh
en y
ou
nee
d it
, fo
r as
lon
g as
you
nee
d it
. C
ontin
uou
s F
low
wat
er
hea
ters
wor
k d
iffe
ren
tly f
rom
sto
rage
wat
er h
eate
rs,
only
hea
ting
on d
eman
d r
ath
er t
han
hea
ting
and
sto
rin
g w
ater
un
til n
eed
ed.
5 S
tar
ener
gy e
ffic
ien
t R
hee
m C
ontin
uou
s
Flo
w h
eate
rs a
re g
ood
for
th
e en
viro
nm
ent.
Mou
nte
d t
o
the
wal
l an
d t
akin
g u
p le
ss s
pac
e, t
hey
are
idea
l for
a
com
pac
t h
ome
site
or
apar
tmen
t.
WIT
H R
HE
EM
YO
U’R
E IN
CO
NTR
OL
Rh
eem
del
iver
s ad
ded
saf
ety
by
pu
ttin
g yo
u in
con
trol
of
the
hot
wat
er in
you
r h
ome.
Rhe
em S
tand
ard
and
Del
uxe
Elec
tron
ic T
empe
ratu
re
Con
trol
lers
are
op
tion
al o
n a
ll m
odel
s, a
llow
ing
you
to
choo
se t
he
exac
t te
mp
erat
ure
you
nee
d a
nd
to
guar
d
agai
nst
sca
ldin
g. R
hee
m B
ath
room
Con
trol
lers
can
be
mod
e, t
o tu
rn o
ff t
he
wat
er f
low
on
ce t
he
bat
h is
fill
ed.
RH
EE
M W
ATE
R S
TAR
®
WA
TER
SAV
ING
SYS
TEM
wit
h a
ll b
ran
ds
of c
ontin
uou
s fl
ow w
ater
hea
ters
. It
is a
n
easy
way
to
hav
e fa
ster
hot
wat
er,
min
imis
e w
ater
was
tage
and
red
uce
en
ergy
usa
ge in
th
e h
ome.
Con
tinu
ous
Flo
w w
ater
hea
ters
can
was
te w
ater
wai
ting
for
the
hea
ting
mec
han
ism
to
reac
h f
ull
tem
per
atu
re.
Ind
epen
den
t re
sear
ch s
how
s a
Con
tinu
ous
Flo
w w
ater
hea
ter
in a
typ
ical
hom
e ca
n o
n a
vera
ge w
aste
bet
wee
n
1.2
an
d 2
.5L
of w
ater
wh
en t
he
hot
wat
er t
ap is
tu
rned
on
wh
ich
eq
uat
es t
o 13
5L
per
day
.24
Sta
r en
sure
s h
ot w
ater
flo
ws
imm
edia
tely
, sa
vin
g w
ater
and
en
ergy
.
Rh
eem
Wat
er S
tar
is e
asily
inst
alle
d a
nd
com
es w
ith
a
5 y
ear
war
ran
ty.2
3 T
her
e is
no
extr
a el
ectr
ical
wir
ing,
it h
as
size
as
a C
ontin
uou
s fl
ow w
ater
hea
ter.
Rh
eem
Wat
er S
tar
can
not
be
inst
alle
d w
ith
a 5
0°C
Con
tinu
ous
Flo
w W
ater
Hea
ter
or w
ith
rem
ote
tem
per
atu
re c
ontr
olle
rs.
A t
emp
erin
g va
lve
may
be
req
uir
ed t
o b
e fi
tted
in
acco
rdan
ce w
ith
AS
/NZ
S 3
50
0:4
.
5 S
tar
ener
gy e
ffic
ien
t
Rh
eem
Con
tinu
ous
Flo
w
hea
ters
are
goo
d f
or t
he
envi
ron
men
t.
Mod
el N
um
ber
: 8
740
27
WH
Y R
HE
EM
CO
NTI
NU
OU
S F
LO
W?
Siz
es t
o su
it e
very
hom
e, a
par
tmen
t or
fam
ily
–
12
L,
16L,
18
L,
20
L,
24
L an
d 2
7L
/min
ute
capac
itie
s.2
0
5 S
tar
ener
gy r
atin
g to
sav
e m
oney
an
d t
he
envi
ron
men
t.
Des
igne
d fo
r A
ustr
alia
’s t
ough
con
diti
ons,
com
bin
ing
inte
rnat
ion
al e
xper
tise
wit
h o
ver
70
yea
rs o
f ex
per
ien
ce
in A
ust
ralia
.
10 y
ear
war
rant
y.2
2
Flam
esaf
e® o
verh
eat
prot
ecti
on,
wh
ich
au
tom
atic
ally
shu
ts d
own
you
r h
eate
r sh
ould
it o
verh
eat.
Rhe
em E
Z LI
NK
® d
eliv
ers
up
to
54
L/m
inu
te b
y lin
kin
g
2 R
hee
m u
nit
s to
act
as
one,
th
ereb
y d
oub
ling
cap
acit
y.2
0
Rhe
em Q
Fac
torTM
for
rap
id h
ot w
ater
eve
ry t
ime,
wit
hou
t
the
flu
ctu
atio
n w
hen
mu
ltip
le t
aps
dem
and
hot
wat
er,
wh
ich
can
occ
ur
wit
h s
ome
Con
tinu
ous
Flo
w u
nit
s.
Fam
ily
safe
ty w
ith
ele
ctro
nic
con
trol
for
acc
ura
te a
nd
relia
ble
wat
er t
emp
erat
ure
, re
du
cin
g th
e ri
sk o
f sc
ald
ing.
Ele
ctro
nic
Rem
ote
Tem
per
atur
e C
ontr
olle
rs f
or a
ccu
rate
sett
ing
of t
he
idea
l an
d s
afes
t te
mp
erat
ure
.
Sol
ar r
eady
Rh
eem
70
ºC c
apab
le m
odel
s ar
e co
mp
atib
le
wit
h s
olar
sys
tem
s w
ith
out
the
nee
d f
or s
pec
ial f
ittin
gs.2
5
Indo
or m
odel
s w
ith
mat
ched
Rh
eem
cer
tifi
ed f
lue
syst
em
Fact
ory
pre-
set
50
ºC m
odel
s av
aila
ble,
req
uir
ing
no
tem
per
ing
valv
e.2
1
Full
tec
hnic
al s
uppor
t th
rou
gh R
hee
m’s
Nat
ion
al
Ser
vice
Net
wor
k.
Com
pac
t si
ze f
or f
lexi
bili
ty in
des
ign
to
suit
ever
y
inst
alla
tion
.
Ava
ilab
le t
o su
it e
ithe
r N
atur
al G
as o
r P
ropan
e
Indo
or 2
7L
mod
el a
vail
able
, w
ith
mat
ched
flu
e sy
stem
.
DE
SIG
NE
D T
O D
ISA
PP
EA
R
You
r R
hee
m C
ontin
uou
s F
low
wat
er h
eate
r ca
n b
e n
eatly
hid
den
aw
ay t
o sa
ve e
ven
mor
e sp
ace:
Pip
e co
vers
in m
atch
ing
colo
ur
will
con
ceal
all
pip
ewor
k.
Rec
ess
box
es w
ill s
et y
our
Rh
eem
into
th
e w
all.
INST
ALL
AC
OM
ES O
N S
TEA
DY
, HO
T A
ND
ST
RO
NG
14
15
SOLA
R C
OLL
EC
TO
R M
OD
EL
S20
0 &
T2
00
Dim
en
sio
ns
an
d S
pe
cifi
cati
on
s W
idth
(F)
mm
1
02
2H
eig
ht
(G)
mm
1
93
7D
ep
th (
H)
mm
7
0
SOLA
R C
OLL
EC
TO
R M
OD
EL
NP
T 2
00
Dim
en
sio
ns
an
d S
pe
cifi
cati
on
s W
idth
(F)
mm
1
02
2H
eig
ht
(G)
mm
1
93
7D
ep
th (
H)
mm
7
0
RH
EEM
PR
EM
IER
® H
ILIN
E S
OLA
R H
OT
WA
TER
HEA
TER
RH
EEM
LO
LIN
E S
OLA
R H
OT
WA
TER
HEA
TER
RH
EEM
HIL
INE
® S
OLA
R H
OT
WA
TER
HEA
TER
War
rant
y, te
rms a
nd c
ondi
tions
1. E
nerg
y red
uctio
n of
up
to 8
0% b
ased
on A
ustra
lian
Gove
rnm
ent A
ppro
ved
TRNS
YS si
mul
ation
mod
ellin
g an
d ap
ply w
hen
repl
acin
g an
elec
tric w
ater
he
ater
with
a R
heem
Sola
r wat
er h
eate
r in
Zone
3.
2. R
heem
Pre
mie
r® Lo
line
/ Lol
ine
/ Hili
ne®
5 ye
ar cy
linde
r, he
at ex
chan
ger a
nd so
lar p
anels
, 3 ye
ar la
bour
on cy
linde
r and
hea
t exc
hang
er, 1
year
pa
rts in
cludi
ng la
bour
. App
lies t
o dom
estic
inst
alla
tions
only.
3. R
heem
Pre
mie
r® H
iline
6 ye
ar cy
linde
r, 5
year
sola
r pan
els, 1
year
labo
ur on
cylin
der,
1 ye
ar p
arts
inclu
ding
labo
ur.
4. G
reen
hous
e gas
emiss
ion sa
vings
bas
ed u
pon
inst
allin
g a
5113
40/2
NPT S
olar H
ot W
ater
hea
ter,
when
repl
acin
g an
elec
tric w
ater
hea
ter.
5. A
ny fi
nanc
ial s
avin
gs w
ill va
ry de
pend
ing
upon
type
of R
heem
Sola
r sys
tem
inst
alled
, orie
ntat
ion a
nd in
clina
tion
of th
e sola
r coll
ecto
rs, t
ype o
f wat
er
heat
er b
eing
repl
aced
, hot
wat
er co
nsum
ption
and
fuel
tarif
f. M
axim
um fi
nanc
ial s
avin
gs of
f you
r hot
wat
er b
ill a
re a
chiev
able
when
repl
acin
gan
elec
tric w
ater
hea
ter o
n co
ntin
uous
tarif
f.6.
Elig
ibili
ty cr
iteria
app
ly.
7. 5
9127
0 sh
ould
be u
sed
with
T200
sola
r pan
els in
Vict
oria
and
Sou
th A
ustra
lia.
AS
349
8W
NK
A00
153
Certified Product
Qua
lity
ISO
900
1
Certified System Aus
tral
ian
Sta
ndar
dA
S 2
712
Lic
757
SA
I Glo
bal
RH
EEM
PR
EM
IER
® L
OLIN
E S
OLA
R H
OT
WA
TER
HEA
TER
RH
EEM
SO
LA
RH
OT W
ATER
PR
OD
UC
T D
ATA
Dim
en
sio
ns
& S
pe
cifi
cati
on
s
RH
EEM
PR
EM
IER
® H
ILIN
E S
OLA
R H
OT
WA
TER
HEA
TER
GAS
BOOS
TED
ELEC
TRIC
BOO
STED
GAS
BOOS
TED
ELEC
TRIC
BOO
STED
GAS
BOOS
TED
ELEC
TRIC
BOO
STED
GAS
BOOS
TED
ELEC
TRIC
BOO
STED
RH
EEM
PR
EM
IER
® L
OLIN
E S
OLA
R H
OT
WA
TER
HEA
TER
RH
EEM
LO
LIN
E S
OLA
R H
OT
WA
TER
HEA
TER
Dim
en
sio
ns
& S
pe
cifi
cati
on
s
Dim
en
sio
ns
& S
pe
cifi
cati
on
s
RH
EEM
HIL
INE
® S
OLA
R H
OT
WA
TER
HEA
TER
Dim
en
sio
ns
& S
pe
cifi
cati
on
s
RH
EEM
PR
EM
IER
® H
ILIN
E S
OLA
R H
OT
WA
TER
HEA
TER
GAS
BOOS
TED
ELEC
TRIC
BOO
STED
GAS
BOOS
TED
ELEC
TRIC
BOO
STED
GAS
BOOS
TED
ELEC
TRIC
BOO
STED
GAS
BOOS
TED
ELEC
TRIC
BOO
STED
RH
EEM
PR
EM
IER
® L
OLIN
E S
OLA
R H
OT
WA
TER
HEA
TER
RH
EEM
LO
LIN
E S
OLA
R H
OT
WA
TER
HEA
TER
Dim
en
sio
ns
& S
pe
cifi
cati
on
s
Dim
en
sio
ns
& S
pe
cifi
cati
on
s
RH
EEM
HIL
INE
® S
OLA
R H
OT
WA
TER
HEA
TER
INST
ALL
AC
OM
ES O
N S
TEA
DY
, HO
T A
ND
ST
RO
NG
16
17
H
Di-
310
M
Pi-
325
M
Ps-
325
Pro
duct
Cod
e 5
5131
0
551
325
5
61325
Num
ber
of P
eopl
e (M
oder
ate
Clim
ate)
3
-6
2-5
2-4
Dim
ensi
ons
Hei
ght
(mm
)
Mod
ule:
N
/A
1018
10
34
Tank
: 18
70
1631
16
30
Wid
th (
mm
)
Mod
ule:
N
/A
N/A
575
Tank
: 670
6
38
64
0
Dep
th (
mm
)
Mod
ule:
N
/A
N/A
3
32
Tank
: 679
86
3
676
Wei
ght
Hea
t P
ump
mod
ule
(kg)
4
8
48
5
0
Tank
(kg
) 87
8
8
88
Tech
nica
l
Cap
acit
y (L
) 31
0
325
325
Pow
er in
put
(Wat
ts)
130
0
80
0
80
0
Ref
rige
rant
R
134
a R
134
a R
134
a
Ele
men
t Siz
es (
kW)
2.4
or
3.6
1.
8, 2.4
or
3.6
2.4
or
3.6
Boo
st C
apac
ity
(L)
22
0
180
18
0
Wat
er C
onne
ctio
ns &
Set
tings
Inle
t (R
P)
¾ /
20
¾
/ 2
0
¾ /
20
Out
let
(RP
) ¾
/ 2
0
¾ /
20
¾
/ 2
0
Tank
Rel
ief
Valv
e S
ettin
g (k
Pa)
10
00
10
00
10
00
EC
V S
ettin
g (k
Pa)
8
50
8
50
8
50
Max
imum
Mai
ns P
ress
ure
Wit
h EC
V (k
Pa)
6
80
6
80
6
80
Wit
hout
EC
V (k
Pa)
8
00
8
00
8
00
Min
. Wat
er S
uppl
y Pr
essu
re (
kPa)
2
00
2
00
2
00
MPi-3
25M
Ps-
325
HD
i-31
0
War
rant
y, te
rms a
nd c
ondi
tions
8.
The i
mpa
ct on
an
elect
ricity
acc
ount
will
dep
end
on th
e tar
iff a
rrang
emen
t of t
he w
ater
hea
ter b
eing
repl
aced
and
whe
re yo
u liv
e. Th
ese R
heem
Hea
t
Pum
p wa
ter h
eate
rs (m
odel
depe
ndan
t) ar
e rec
omm
ende
d fo
r con
nect
ion to
eith
er 2
4 ho
ur co
ntin
uous
tarif
f or e
xtend
ed of
f pea
k (m
in 1
6 ho
urs/
day).
Be
fore
pur
chas
e con
sult
your
ener
gy p
rovid
er fo
r mor
e inf
orm
ation
on co
st co
mpa
rison
s.9.
He
at P
ump
warra
nty c
ondi
tions
. 5 ye
ar cy
linde
r war
rant
y, 3
year
labo
ur on
cylin
der,
2 ye
ar on
seal
ed sy
stem
inclu
ding
labo
ur, 1
year
on a
ll ot
her
pa
rts a
nd la
bour
. App
lies t
o dom
estic
inst
alla
tions
only.
Am
ende
d wa
rrant
y may
app
ly wh
ere a
gov
ernm
ent r
ebat
e has
bee
n re
ceive
d fo
r the
sola
r wat
er
he
ater
. Pho
ne 1
31 0
31 fo
r det
ails.
10. E
nerg
y and
gre
enho
use g
as em
ission
s red
uctio
n of
up
to 6
5% b
ased
on A
ustra
lian
Gove
rnm
ent A
ppro
ved
TRNS
YS si
mul
ation
mod
ellin
g an
d ap
ply w
hen
re
plac
ing
an el
ectri
c wat
er h
eate
r with
a R
heem
Hea
t Pum
p wa
ter h
eate
r in
Zone
3.
11. A
ssum
es co
nsum
er el
igib
ility
for r
ebat
es. E
ligib
ility
crite
ria a
pply.
12
. Any
fina
ncia
l sav
ings
will
vary
depe
ndin
g up
on ty
pe of
Rhe
em H
eat P
ump
inst
alled
, typ
e of w
ater
hea
ter b
eing
repl
aced
, hot
wat
er co
nsum
ption
an
d fu
el ta
riff.
M
axim
um fi
nanc
ial s
avin
gs of
f you
r hot
wat
er b
ill a
re a
chiev
able
when
repl
acin
g an
elec
tric w
ater
hea
ter o
n co
ntin
uous
tarif
f.
AS
349
8 W
NK
A00
153
Certified Product
Qua
lity
ISO
900
1
Certified System Aus
tral
ian
Sta
ndar
dA
S 2
712
Lic
757
SA
I Glo
bal
RH
EEM
HEAT P
UM
PH
OT W
ATER
PR
OD
UC
T D
ATA
25
50
80
125
160
250
315
400
Rhe
emgl
as® S
ingl
e E
lem
ent
5 y
ears
1
11
02
5
19
10
50
1
11
08
0
11
11
25
1
11
16
0
11
12
50
1
11
31
5
11
14
00
Rhe
emgl
as® T
win
Ele
men
t 5
yea
rs
– –
– –
16
21
60
1
62
25
0
16
23
15
1
62
40
0R
heem
Opt
ima®
Sin
gle
Ele
men
t 1
0 y
ears
–
– –
– –
41
12
50
4
11
31
5
41
14
00
Rhe
em O
ptim
a® T
win
Ele
men
t 1
0 y
ears
–
– –
– –
46
22
50
4
62
31
5
46
24
00
Rhe
emP
lus®
Sin
gle
Ele
men
t 5
yea
rs
– –
– 1
21
12
5
12
11
60
1
21
25
0
12
13
15
Hot
Wat
er D
eliv
ery
Litr
es
20
5
0
80
1
25
1
60
2
50
3
15
4
00
Sto
rage
Cap
acit
y Li
tres
2
5
53
9
0
13
5
16
5
27
0
32
4
41
2B
oost
Cap
acit
y Tw
in E
lem
ent
–
– –
– –
45
5
0
50
9
0
Dim
en
sio
ns
App
rox.
Wei
ght
Em
pty
11
1,
41
1,
16
2,
46
2 a
nd 1
21
mod
els
have
lef
t ha
nd c
onne
ctio
ns.
19
1 m
odel
s ha
ve l
eft
and
righ
t ha
nd c
onne
ctio
ns a
nd a
re a
vail
able
in
05
0 L
itre
del
iver
y ca
paci
ty o
nly.
Rhe
emgl
as s
ingl
e el
emen
t m
odel
s w
ith
righ
t ha
nd c
onne
ctio
ns o
nly
are
avai
labl
e in
80
and
12
5 L
itre
del
iver
y ca
paci
ties
and
hav
e a
17
1 p
refi
x.Te
chni
cal
data
is
subj
ect
to c
hang
e.
LEFT
HAN
D CO
NNEC
TIONS
RHEE
MGL
AS A
ND O
PTIM
ARH
EEM
OPT
IMA®
RHEE
MGL
AS®
AND
RHEE
MPLU
S®
RHEE
MPL
US
INLE
T
OUTL
ETRE
LIEF V
ALVE
AD
AD
G
E
B
CC
L
JºJº
Jº
Jº
Hº
HºHº
HºC
BBK
EF
FCA
BLE
ENTR
Y
CABL
E EN
TRY
HOT
WAT
ER
OUTL
ET
COLD
WAT
ER
OUTL
ET
DUAL
HAN
DED
CONN
ECTIO
NSWar
rant
yM
odel
A
mm
3
90
6
95
9
40
1
34
0
16
10
1
39
5
16
40
1
84
0B
m
m
38
5
39
3
48
0
48
0
48
0
64
0
64
0
69
0C
m
m
42
0
42
9
51
5
51
5
51
5
70
0
70
0
75
5D
m
m
13
0
39
7
70
2
11
02
1
33
2
11
17
1
31
7
14
79
E
mm
1
16
1
42
6
4
64
1
04
7
3
11
3
12
1F
mm
7
5
80
8
4
84
8
4
12
8
12
8
12
9G
m
m
– –
– –
10
85
1
00
5
12
55
1
34
6H
de
g 2
6
26
2
3
23
2
3
32
3
2
30
J de
g 6
5
59
5
8
58
5
8
88
8
8
83
K
mm
–
– –
54
5
54
5
70
5
70
5
–L
mm
–
– –
18
3
18
3
26
2
26
2
–
Kg
18
2
3
34
4
9
57
7
4
89
1
12
War
rant
y, te
rms
and
cond
ition
s13
. War
rant
y: 5
year
cylin
der w
arra
nty,
3 ye
ar la
bour
war
rant
y on
the c
ylind
er, 1
year
par
ts a
nd
labo
ur w
arra
nty o
n al
l oth
er co
mpo
nent
s for
dom
estic
(non
-com
mer
cial)
inst
alla
tions
. See
Ow
ner’s
Gui
de fo
r con
ditio
ns.
14. W
arra
nty:
10 ye
ar cy
linde
r war
rant
y, 5
year
labo
ur w
arra
nty o
n th
e cyli
nder
, 1 ye
ar p
arts
and
la
bour
war
rant
y on
all o
ther
com
pone
nts f
or d
omes
tic (n
on-c
omm
ercia
l) in
stal
latio
ns. S
ee
Owne
r’s G
uide
for c
ondi
tions
.15
. 50º
C fa
ctor
y pre
-set
mod
els su
pply
hot w
ater
at a
max
imum
50º
C at
all
outle
ts in
acc
orda
nce
with
AS
3498
. Som
e app
licat
ions m
ay re
quire
tem
perin
g, re
fer t
o AS
3500
:4.
2550
125
--
-
-1
2-3
80 - 1-2
160
250
400
5-9
315
4-6
3-5
2-4
4-6
2-4
1-3
-
Mod
el (L
itres
)16
025
040
0
PPH*
– O
ff-pe
ak ta
riff
5-9
315
4-6
3-5
2-4
4-7
3-4
2-3
1-3
PPH*
– C
ontin
uous
tarif
f
PPH*
– O
ff-pe
ak ta
riff
PPH*
– C
ontin
uous
tarif
f
PPH*
– O
ff-pe
ak ta
riff
PPH*
– C
ontin
uous
tarif
f
Mod
el (L
itres
)16
025
040
0
PPH*
– O
ff-pe
ak ta
riff
5-9
315
4-6
3-5
2-4
4-7
3-4
2-3
1-3
PPH*
– C
ontin
uous
tarif
f
*Peo
ple
per h
ouse
hold
.
PPH*
– O
ff-pe
ak ta
riff
PPH*
– C
ontin
uous
tarif
f
PPH*
– O
ff-pe
ak ta
riff
PPH*
– C
ontin
uous
tarif
f
twin
ele
men
t
Mod
el (L
itres
)sin
gle
elem
ent
Mod
el (L
itres
)sin
gle
elem
ent
Mod
el (L
itres
)25
031
540
0
PPH*
– O
ff pe
ak ta
riff
Sing
le /
Twin
1-3/
2-3
2-4/
3-4
4-6/
4-7
3-5
4-6
5-9
PPH*
– C
ontin
uous
tarif
fSi
ngle
/ Tw
in
RH
EEM
ELEC
TR
IC S
TO
RA
GE
HO
T W
ATER
PR
OD
UC
T D
ATA
INST
ALL
AC
OM
ES O
N S
TEA
DY
, HO
T A
ND
ST
RO
NG
18
19
Rhee
m 1
2/16
/18/
20
HOT W
ATER
OUTL
ETCO
LD W
ATER
INLE
TGA
SIN
LET
Rhee
m 2
4
HOT W
ATER
OUTL
ETCO
LD W
ATER
INLE
TGA
SIN
LET
BC
A
Rh
eem
12
Rhee
m 16
Rh
eem
18
Rhee
m 20
Rh
eem
24
Rhee
m 27
Rh
eem
Wate
r Sta
r
Mode
l Num
ber
8760
12NF
/PF
8740
12NF
/PF
876M
16NF
/PF
874M
16NF
/PF
8760
18NF
/PF
8740
18NF
/PF
8760
20NF
/PF
8740
20NF
/PF
8750
24NF
/PF
8710
24NF
/PF
8760
27NF
/PF
8740
27NF
/PF
W810
0401
87
5M24
NF/P
F 87
1M24
NF/P
F Ma
ximum
Tem
pera
ture
°C
50
60
50
60
50
60
50
60
50
60
50
60
70
Num
ber o
f Bat
hroo
ms
1 –
1.5
1 –
1.5
1 –
1.5
1.5
– 2
2 –
2.5
2.5
– 3
– Ga
s Typ
e Na
tura
l Gas
/Pro
pane
Na
tura
l Gas
/Pro
pane
Na
tura
l Gas
/Pro
pane
Na
tura
l Gas
/Pro
pane
Na
tura
l Gas
/Pro
pane
Na
tura
l Gas
/Pro
pane
–
GAS
Ener
gy R
atin
g
5.9
Star
s 5.
3 St
ars
5.3
Star
s 5.
0 St
ars
5.1
Star
s 5.
8 St
ars
–Flo
w Ra
te L/
Min
at 2
5°C
Rise
12
/Min
16
L/Mi
n 18
L/Mi
n 20
L/Mi
n 24
L/Mi
n 27
L/Mi
n –
Mini
mum
Ope
ratin
g Flo
w Ra
te
2.7L
/Min
2.
7L/M
in
2.7L
/Min
2.
7L/M
in
2.7L
/Min
2.
0L/M
in
–No
min
al G
as C
onsu
mpt
ion
94 M
J/Hr
126
MJ/H
r 14
0 MJ
/Hr
153
MJ/H
r 18
8 MJ
/Hr
205
MJ/H
r –
Dim
ensio
nsA
- H
eight
mm
52
0 52
0 52
0 52
0 56
5 60
0 56
5 B
- W
idth
mm
35
0 35
0 35
0 35
0 35
0 35
0 35
0 C
- D
epth
mm
16
0 16
0 16
0 16
0 20
5 21
5 19
0De
pth
– fro
m w
all t
o Hot
Wat
er O
utlet
51
51
51
51
12
7 84
_
Dept
h –
from
wal
l to C
old W
ater
Inlet
43
43
43
43
53
64
_
De
pth
– fro
m w
all t
o Gas
Inlet
45
45
45
45
10
3 97
_
Weig
ht (e
mpt
y) 18
kg
18kg
18
kg
18kg
21
kg
23kg
12
.5Kg
Max.
Wate
r Sup
ply P
ress
ure
1000
kPa
1000
kPa
1000
kPa
1000
kPa
1000
kPa
1000
kPa
1000
kPa
Min.
Wat
er S
uppl
y Pre
ssur
e 14
0kPa
14
0kPa
14
0kPa
14
0kPa
14
0kPa
14
0kPa
–
Cold
Wat
er C
onne
ction
R
¾ /
20
R ¾
/ 20
R
¾ /
20
R ¾
/ 20
R
¾ /
20
R ¾
/ 20
R
¾ /
20Ho
t Wat
er C
onne
ction
R
¾ /
20
R ¾
/ 20
R
¾ /
20
R ¾
/ 20
R
¾ /
20
R ¾
/ 20
R
¾ /
20Ga
s Con
nect
ion
R ¾
/ 20
R
¾ /
20
R ¾
/ 20
R
¾ /
20
R ¾
/ 20
R
¾ /
20
–
Tem
pera
ture
Con
trolle
rs
Kitc
hen
2998
50
2998
50
2998
50
2998
50
2998
50
2998
50
–Ba
thro
om 1
29
9851
29
9851
29
9851
29
9851
29
9851
29
9851
–
Bath
room
2
2998
52
2998
52
2998
52
2998
52
2998
52
2998
52
–
Delu
xe Te
mpe
ratu
re
Cont
rolle
rsKi
tche
n 29
9 58
29
9858
29
9858
29
9858
29
9858
29
9858
–
Bath
room
1
2998
59
2998
59
2998
59
2998
59
2998
59
2998
59
–Ba
thro
om 2
29
9860
29
9860
29
9860
29
9860
29
9860
29
9860
–
Acce
ssor
ies
Pipe
Cov
er
2998
41
2998
41
2998
41
2998
41
2998
48
2998
30
– Re
cess
Box
29
9842
29
9842
29
9842
29
9842
29
9842
29
9831
–
Rhee
m E
Z Lin
k Kit
2901
41
2901
41
2901
41
2901
41
N/A
2901
41
– Wa
ll Mo
unt S
ecur
ity K
it
2998
68
2998
68
2998
68
2998
68
2998
68
2998
68
– Se
curit
y Cag
e 29
9867
29
9867
29
9867
29
9867
29
9867
29
9867
–
Powe
r –
– –
– –
– 24
0V A
C
War
rant
y, te
rms a
nd c
ondi
tions
20. G
uide
only,
subj
ect t
o am
bien
t wat
er te
mpe
ratu
re a
nd p
ress
ure,
corre
ct p
ipe s
izing
and
app
lianc
e flow
rate
s.21
. 50º
C fa
ctor
y pre
-set
mod
els su
pply
hot w
ater
at a
max
imum
50º
C at
all
outle
ts in
acc
orda
nce w
ith A
S349
8. S
ome
ap
plica
tions
may
requ
ire te
mpe
ring,
refe
r to A
S 35
00:4
. 60º
C m
odels
mus
t hav
e a te
mpe
ring
valve
inst
alled
in
acco
rdan
ce w
ith A
S 35
00:4
. 22
. War
rant
y Con
ditio
ns: 1
0 Ye
ars p
arts
and
3 Y
ears
labo
ur on
Hea
t Exc
hang
er, 3
Yea
rs p
arts
& la
bour
on ot
her
com
pone
nts,
when
inst
alled
in a
dom
estic
dwe
lling
. For
all
othe
r ins
talla
tions
, the
war
rant
y per
iod is
1
Year
par
ts a
nd la
bour
on H
eat E
xcha
nger
and
othe
r com
pone
nts.
GLOS
SARY
OF
TERM
SFl
ames
afe®
– a
uni
que
Rhee
m s
afet
y pro
tect
ion
feat
ure
that
aut
omat
ical
ly sh
uts
down
the
cont
inuo
us fl
ow w
ater
hea
ter s
houl
d a
faul
t dev
elop
.Q
Fact
orTM
– a
uni
que
Rhee
m fe
atur
e th
at k
eeps
the
heat
er in
read
ines
s so
hot
wat
er
deliv
ery i
s as
fast
as
poss
ible
, and
at c
onsi
sten
t tem
pera
ture
.
Rhee
m 2
7
GAS
INLE
TCO
LD W
ATER
INLE
THO
T WAT
EROU
TLET
23. R
heem
Wat
er S
tar w
arra
nty:
5 ye
ar su
pply
on cy
linde
r, 3
year
supp
ly &
labo
ur on
cylin
der,
1 ye
ar fu
ll
parts
& la
bour
.24
. Ave
rage
was
tage
incu
rred
at w
ater
hea
ter o
utlet
per
dem
and
until
wat
er re
ache
s with
in 5
ºC of
60º
C se
t
tem
pera
ture
, bas
ed on
19
dem
ands
per
day
, with
the w
ater
hea
ter c
old ea
ch ti
me t
ap is
turn
ed on
and
20
0L/d
ay a
vera
ge h
ot w
ater
cons
umpt
ion. S
ourc
e: W
ELS
Wat
er W
asta
ge of
Inst
anta
neou
s Gas
Wat
er
Heat
ers –
200
8. ©
Com
mon
weal
th of
Aus
tralia
200
8.25
. App
lies t
o 70º
C ca
pabl
e mod
els w
hen
set t
o 70º
C.
RH
EEM
CO
NTIN
UO
US
FLO
WH
OT W
ATER
PR
OD
UC
T D
ATA
Reco
very
rate
– th
e vo
lum
e of
wat
er a
hea
ter c
an re
heat
in o
ne h
our.
Mea
sure
d as
the
volu
me
of
com
plet
ely c
old
wate
r (sh
ould
the
wate
r hea
ter b
e ru
n co
mpl
etel
y out
) tha
t can
be
heat
ed to
45º
C ov
er
the
cold
wat
er te
mpe
ratu
re.
Firs
t Hou
r Cap
acity
– a
mea
sure
of w
ater
hea
ter c
apac
ity th
at c
ombi
nes
both
the
stor
ed h
ot w
ater
vo
lum
e &
the
hour
ly re
cove
ry ra
te (e
g: if
a w
ater
hea
ter h
as s
tora
ge c
apac
ity o
f 130
L an
d a
reco
very
ra
te o
f 200
L/ho
ur, i
ts F
irst H
our C
apac
ity is
330
L).
War
rant
y, te
rms a
nd c
ondi
tions
16. G
uide
only,
subj
ect t
o am
bien
t wat
er te
mpe
ratu
re a
nd p
ress
ure a
nd co
rrect
pip
e sizi
ng.
17. 5
year
cylin
der w
arra
nty,
3 ye
ar la
bour
on cy
linde
r, 1
year
par
ts a
nd la
bour
war
rant
y on
all o
ther
com
pone
nts f
or d
omes
tic (n
on-c
omm
ercia
l) in
stal
latio
ns.
18. 7
year
cylin
der w
arra
nty,
3 ye
ar la
bour
on cy
linde
r, 1
year
par
ts a
nd la
bour
on a
ll ot
her c
ompo
nent
s fo
r dom
estic
(non
-com
mer
cial)
inst
alla
tions
.19
. 10
year
cylin
der a
nd S
uper
Flue w
arra
nty,
5 ye
ar la
bour
on cy
linde
r and
Sup
erFlu
e, 1
year
par
ts a
nd la
bour
wa
rrant
y on
all o
ther
com
pone
nts f
or d
omes
tic (n
on-c
omm
ercia
l) in
stal
latio
ns.
So
me a
pplic
ation
s req
uire
a te
mpe
ring
valve
in a
ccor
danc
e with
AS/
NZS
3500
:4.
# No
t ava
ilabl
e in
NSW
+ Onl
y ava
ilabl
e in
NSW
Numb
er of
Peo
ple:
Mode
rate
Clim
ate
1-3
2-4
3-5
1-3
2-4
3-5
2-4
3-5
2-5
3-6
2-4
3-5
Cool
Clim
ate
1-2
2-3
3-4
1-2
2-3
3-4
2-3
3-4
2-4
3-5
2-3
3-4
Warra
nty (
year
s)15,16
,17
5 5
5 7
7 7
5 5
10
10
5 5
Gas T
ype
Natu
ral G
as/P
ropan
e Na
tura
l Gas
/Prop
ane
Natu
ral G
as/P
ropan
e Na
tura
l Gas
/Prop
ane
Natu
ral G
as/P
ropan
eGA
S Ene
rgy R
ating
3.4
3.2
3.2
4.1
4.3
4.0
5.3
5.3
5.2
5.0
3.4
3.2
Stora
ge C
apac
ity (L
itres
) 85
13
0 16
0 90
13
5 17
0 13
0 16
0 13
0 16
0 13
5 17
0Re
cove
ry Ra
te (L/
Hour
@45
ºC) N
atur
al Ga
s 12
5 15
0 17
0 10
0 11
7 11
7 14
2 14
2 20
0 20
0 12
0 12
6Fir
st Ho
ur C
apac
ity (L
itres
) 21
0 28
0 33
0 19
0 25
2 28
7 27
2 30
2 33
0 36
0 25
5 29
6 Ho
urly
Gas C
onsu
mptio
n (MJ
/Hr)N
at/P
rop
30/3
0 35
/35
40/4
0 25
/25
27/2
6 27
/26
30/3
0 30
/30
42/4
2 42
/42
30/3
0 30
/30
Dime
nsion
s mm
A
1198
15
98
1898
11
58
1558
18
58
1622
19
22
1600
19
00
1615
19
15
B 42
2 42
2 42
2 42
2 42
2 42
2 48
5 48
5 48
5 48
5 42
5 42
5
C
502
502
502
502
502
502
556
556
558
558
500
500
D
58
8 98
8 12
13
588
988
1213
98
8 12
13
988
1213
98
8 12
13
E 32
8 32
8 40
3 32
8 32
8 40
3 32
8 40
9 32
8 40
9 32
8 40
3
F 29
8 29
8 29
8 29
8 29
8 29
8 29
8 29
8 29
8 29
8 29
7 29
7
G 10
78
1478
17
78
1078
14
78
1778
60
0 60
0 77
0 77
0 14
90
1790
H
(Rhe
emPlu
s® O
nly)
545
545
J
(Rhe
emPlu
s® O
nly)
182
182
K
473
473
473
473
473
473
520
520
520
520
490
490
L
208
208
208
208
208
208
240
240
252
252
213
213
M
297
297
299
299
75
75
N
97
97
93
93
Weigh
t Emp
ty (kg
) 52
68
79
48
59
69
75
85
70
80
54
63
Relie
f Valv
e Sett
ing (k
Pa)
1400
14
00
1400
14
00
1400
Expa
nsion
Con
trol V
alve S
etting
(kPa
) 12
00
1200
12
00
1200
12
00Ma
x Wat
er Su
pply
Pres
sure
:wi
th EC
V (kP
a)
960
960
960
960
960
with
out E
CV (k
Pa)
1120
11
20
1120
11
20
1120
Water
Con
necti
ons
RP ¾
/20
RP ¾
/20
RP ¾
/20
RP ¾
/20
RP ¾
/20
Water
Con
necti
ons (
Rhee
mPlus
)
G¾
BGa
s Con
necti
on
RP ½
/15
RP ½
/15
RP ½
/15
RP ½
/15
90
13
5 17
0 90
13
5 17
0 26
5 29
5 33
0 36
0 13
5 17
0
Mode
l Num
ber
3110
90N0
/P0
3111
35N0
/P0
3111
70N0
/P0
3470
90N0
/P0
3471
35N0
/P0
3471
70N0
/P0
3502
65N0
/P0
3502
95N0
/P0
8503
30N0
/P0
8503
60N0
/P0
3001
35N0
/P0
3001
70N0
/P0
Rhee
mPlus
®
– –
– –
– –
3542
65N0
/P0
3542
95N0
/P0
– –
– –
Rh
eem
3 S
tar#
Rhee
m 4
Sta
r+ Rh
eem
5 S
tar
Rhee
m S
tella
r®
Rhee
m In
door
*
*Flu
e Dia
met
er 7
5mm
HOT O
UTLE
TRE
LIEF V
ALVE
RELIE
F VAL
VE
COLD
INLE
T GAS
INLE
T
BH
LJ
CK
MN
AD E
F
G
GLOS
SARY
OF
TERM
S
RH
EEM
GA
S S
TO
RA
GE
HO
T W
ATER
PR
OD
UC
T D
ATA
INSTALL A
Rheem Australia Pty LtdABN 21 098 823 511
Head Office1 Alan Street, Rydalmere NSW 2116Australia
PO Box 6,Rydalmere NSW 2116Australia
National Sales Phone: 132 552
National Service Phone: 131 031
www.rheem.com.au
® Registered Trademark of Rheem Australia Pty LtdTM Trademark of Rheem Australia Pty Ltd
CONTACT US