RH-Cube 18 HH
High Humidity Dehumidifier
Legal: Copyright© 2019—DewAir™ Corporation. All rights reserved. Specifications and benefits believed correct at the time of release and may vary de-
pending on specific conditions and other circumstances. This brochure is subject to change without advanced notice. Product images may vary slightly. No
warranties expressed or implied other than our product warranty. No DIY—must be installed by a certified HVAC contractor. Version release - Dec. 2019
www.DewAirCorp.com
HVAC contractors and wholesalers in your area
(attach business card here)
DewAir™ products supplied by:
Compared to other brands, RH-Cube™ has:
• Raw capacity — our 2.0 ton system can remove more moisture than a 10 ton air conditioner
• More capacity than our CZ model for non-corrosive applications of high humidity & temp.
• Minimal ducting for simpler installation
• Less constrained electrical supply requirements
• Very low energy usage, very low cost of operation
Optimized to pull more moisture where needed For applications such as greenhouses and industrial processing plants where temperatures and humidity levels are high, the RH-Cube 18 HH model is the ideal choice. In some cases, there can be a deployment of both the HH and CZ models to span a wider range of humidity and temperature where the CZ is only used at lower RH and temperatures by means of automation.
The HH model may have it’s condenser outdoors to reduce heat such as industrial processing plants applications, or indoors to recover heat such as greenhouses for 25,000 BTUs of reheat.
RH-Cube 18 HH application selection
Compact | Capacity | Cost effective
High humidity dehumidifier for select applications
The higher capacity of the HH model needs to be
aligned to applications where the range of indoor
air temperature and range of humidity is within the
recommended region for the HH model. Not ob-
serving this will cause cycling that will reduce effi-
ciency. Please refer to the capacity tables on our
website for guidance or request technical support.
Application example -
Greenhouses
Application example -
Industrial Processing
80°F 80%RH→398 US pints/day
75°F 80%RH→425 US pints/day
70°F 80%RH→444 US pints/day(condenser is placed inside for greenhouses)
Legal: Copyright© 2019—DewAir™ Corporation. All rights reserved. Specifications and benefits believed correct at the time of release and may vary de-
pending on specific conditions and other circumstances. This brochure is subject to change without advanced notice. Product images may vary slightly. No
warranties expressed or implied other than our product warranty. No DIY—must be installed by a certified HVAC contractor. Version release - Dec. 2019
www.DewAirCorp.com
Patents: CA2861757, US2016265805.
Other patents pending.
RH-Cube 18 HH is sold as a
system of two components -
the indoor dehumidifier unit
and the outdoor condenser
unit. Indoor unit should be
installed in a noise tolerant
area as like other HVAC
equipment with blowers.
See online installation
manuals section.
38.2” (97 cm)
44.0” (112 cm)
26.0” (66 cm)
26.0” (66 cm)
27.5” (70 cm)
Dehumdifier unit (indoor) Part number: DA-900-0001
Typical Power Consumption 340 Watts @ 80°F and 60% RH
Blower power, STP performance
336W (0.44 HP), 610 CFM @ 0" WG, 545 CFM@ 0.2"
WG (50 Pascals), 500 CFM@ 0.35 WG (87 Pascals)
Supply Voltage, Cord 120 V - 1 phase, 60 Hz, 6 foot cord (grounded)
Power Circuit (Max Current Draw) 15 A breaker (Max draw 3.2A)
Refrigerant / Liquid & Suction Lines R410A / Liquid 3/8" (9.5 mm) & Suction 3/4" (19 mm)
Drain connection 3/4" (19 mm) NTP threaded female
Refrigerant Maximum Length 82 feet (25m) distance
Refrigerant Maximum Elevation 50 feet (15m) elevation
Control Device (not included) dehumidistat
Output Control Power 24 VAC up to 30 VA to power dehumidistat control
Blower Switch Auto or always on
Return Duct (air into RH-Cube)
Minimum 3 foot duct (MANDATORY). Opening on
top is 12" ( 30.5 cm) x 18" (46 cm)
Supply Duct (air out of RH-Cube)
Duct optional but recommended. Cutout choice on left,
right, top, and back. 8" (20.5 cm) x 14" (35.6 cm)
Other blower duct system connect Refer to installation manual for several options
Service Access Left Side connection pipes, electrical control, blower switch
Service Access Front evaporator coil, four heat exchangers, filter cover
Service Access Top electrical components box
Air Filter (standard recommended) Camfil 24x16x2 30/30 MERV 8 Part # 049880-016
Filter Maintenance
Inspect every 1-2 months, replace every 3-4 months or
as needed
Alternative Air Filter (premium) Camfil 24x16x2 30/30 Dual 9 Part # 0406331-016
Equipment Weight, Ship Weight Equipment 260 lbs (117 Kg), Ship 300 lbs (136 Kg)
Minimum maneuvering weight
Approx 180 lbs (81 Kg) If needed, two front panel doors are easily opened so the 4 heat exchangers weighing 20 lbs each can be removed at client site to
reduce final positioning weight, then reinserted.
Equipment Dimensions (incl. pipes) 44.0"H (112 cm) x 28.4"W (72 cm) x 38.2"L (97 cm)
Shipping Dimensions 47.0"H (120 cm) x 32.0"W (82 cm) x 44.0"L (112 cm)
Dehumidification Performance Outdoor 80°F, total power usage = 1.86 kW
Efficiency Capacity Capacity Sens. Cool.
Indoor
conditions
US Pints /
kWh
US Pints /
Day
US Gal. /
Day
BTUs /
Hour
80F/60RH 7.5 319 39.9 3754
75F/60RH 6.7 285 35.6 3970
75F/50RH N/A N/A N/A N/A
Outdoor 95°F, total power usage = 2.0 kW
Efficiency Capacity Capacity Sens. Cool.
Indoor
conditions
US Pints /
kWh
US Pints /
Day
US Gal. /
Day
BTUs /
Hour
80F/60RH 6.5 310 38.8 3376
75F/60RH 5.6 268 33.5 3564
75F/50RH N/A N/A N/A N/A
Condenser unit (outdoor 2 ton) DewAir™ Part Number: DA-911-0002
Typical Power Consumption 1526 Watts @ 80°F and 60% RH
Supply Voltage (Max/Min V) 208/230 V - 1 phase, 60 Hz, (Min 193V/Max 255V)
Power Circuit (Max Current Draw) 15 A breaker (Max draw 10.3A)
Electrical Conduit 1/2" (12.7 mm) or 3/4" (19 mm)
Refrigerant / Liquid & Suction Lines R410A / Liquid 3/8" (9.5 mm) & Suction 3/4" (19 mm)
Operating Temperature Range 55°F (13°C) - 115°F (46°C) without add-ons
Protection from Low Temperature add outdoor thermostat bimetal sensor
Full Possible Operating
Temperature Range with Add-ons
10°F (-12°C) - 115°F (46°C), add condenser fan
Equipment Weight, Ship Weight Equipment 126 lbs (57 Kg), Ship 141 lbs (64 Kg)
Equipment Dimensions 27.5"H (70 cm) x 26.0"W (66 cm) x 26.0"L (66 cm)
RH-Cube 18 HH Technical and Performance Data Performance measurements simulated and North American safety
certification performed by Intertek in the USA.
28.4” (72 cm)