7
CONSTRUCTION GUIDE LAZY RIVER PUMP SYSTEM PRELIMINARY SYSTEM LAYOUT 1 1 2 3 3 PUMP LOCATION PUMP LOCATION LAZY RIVER 1 DETERMINE CURRENT RETURN LOCATION AND ANGLE (AS PER PLAN) PRELIMINARY SITE LAYOUT AND PUMP LOCATION 2 DETERMINE PIPE ROUTING AND ANGLE FROM RETURN TO PUMP LOCATION. ANGLES ARE TO BE %$6(' 21 )$&725< ),77,1*6 68&+ $6 (/%2:6 21/< 527$7( 3803 TEE TO MEET RETURN PIPE ANGLE. 3 DETERMINE SUCTION DRAIN LOCATION AND PIPE ROUTING AND ANGLE FROM SUCTION OUTLETS TO PUMP LOCATION. ANGLES ARE TO BE BASED ON FACTORY FITTINGS SUCH AS (/%2:6 21/<527$7( 68&7,21 (/%2: $6 1(('(' 72 0((7 SUCTION PIPING ANGLE. NOTE: RETURN PIPING PLANNING DETERMINES PUMP LOCATION BASED ON ANGLES OF PIPING REQUIRED TO MEET PROPER INSTALLATION OF RETURN FITTING TO PRODUCE CURRENT IN DIRECTION OF JUST OFF CENTER OF STREAM CENTERLINE. PLACEMENT OF RETURN FITTING AND SET ANGLE OF FLOW IS FIRST PRIORITY IN DETERMINING SYSTEM LAYOUT. 4 DIG 4' WIDE X 4' DEEP TRENCH FOR PIPE ROUTING AND PUMP PLACEMENT 4 4 4 4 12" TEE WITH (3) 4" RETURN NOZZLE 4'-0" 4'-0" PAGE 1 OF 7 10" OR 12" SCH 40 PVC PIPE RETURN WITH ACCELERATOR NOZZLE 2 10" OR 12" SCH 40 PVC PIPE RETURN WITH ACCELERATOR NOZZLE 12" TEE WITH (3) 4" RETURN NOZZLE REFER TO IMAGE 2 & 4 ON PG. 4 1

RETURN WITH ACCELERATOR NOZZLE LAZY RIVER 3 LAZY RIVER CON DOC.pdf · 3determine suction drain location and pipe routing and angle from suction ... lazy river pump system page 7 of

Embed Size (px)

Citation preview

Page 1: RETURN WITH ACCELERATOR NOZZLE LAZY RIVER 3 LAZY RIVER CON DOC.pdf · 3determine suction drain location and pipe routing and angle from suction ... lazy river pump system page 7 of

33.0°

1

4

7

.0

°

4

5

.

0

°

CONSTRUCTION GUIDE

LAZY RIVER PUMP SYSTEM

PRELIMINARY SYSTEM LAYOUT

33.0°

1

1

2

3

3

PUMP LOCATION

PUMP LOCATION

LAZY RIVER

1 DETERMINE CURRENT RETURN LOCATION AND ANGLE (AS PER PLAN)

PRELIMINARY SITE LAYOUT AND PUMP LOCATION

2 DETERMINE PIPE ROUTING AND ANGLE FROM RETURN TO PUMP LOCATION. ANGLES ARE TO BE

BASED ON FACTORY FITTINGS SUCH AS 11.25°, 22.5°, 45°, 90° ELBOWS ONLY. ROTATE PUMP

TEE TO MEET RETURN PIPE ANGLE.

3 DETERMINE SUCTION DRAIN LOCATION AND PIPE ROUTING AND ANGLE FROM SUCTION

OUTLETS TO PUMP LOCATION. ANGLES ARE TO BE BASED ON FACTORY FITTINGS SUCH AS

11.25°, 22.5°, 45°, 90° ELBOWS ONLY.ROTATE 12" SUCTION 90° ELBOW AS NEEDED TO MEET

SUCTION PIPING ANGLE.

NOTE: RETURN PIPING PLANNING DETERMINES PUMP LOCATION BASED ON ANGLES OF PIPING

REQUIRED TO MEET PROPER INSTALLATION OF RETURN FITTING TO PRODUCE CURRENT

IN DIRECTION OF JUST OFF CENTER OF STREAM CENTERLINE.

PLACEMENT OF RETURN FITTING AND SET ANGLE OF FLOW IS FIRST PRIORITY IN DETERMINING

SYSTEM LAYOUT.

4

5

.

0

°

4 DIG 4' WIDE X 4' DEEP TRENCH FOR PIPE ROUTING AND PUMP PLACEMENT

4

4

4

4

12" TEE WITH

(3) 4" RETURN NOZZLE

4

'

-

0

"

4

'

-

0

"

PAGE

1 OF 7

10" OR 12" SCH 40 PVC PIPE

RETURN WITH ACCELERATOR NOZZLE

2

10" OR 12" SCH 40 PVC PIPE

RETURN WITH ACCELERATOR NOZZLE

12" TEE WITH

(3) 4" RETURN NOZZLE

REFER TO IMAGE 2 & 4 ON PG. 4

1

Page 2: RETURN WITH ACCELERATOR NOZZLE LAZY RIVER 3 LAZY RIVER CON DOC.pdf · 3determine suction drain location and pipe routing and angle from suction ... lazy river pump system page 7 of

10

"

3'-0

" T

O 4

'-0

"

1'-3

"

2"

4"

1'-3

1

2

"

2"

4"

1'-3

1

2

"

PIPING INSTALLATION

4

5

.

0

°

4

5

.

0

°

10

"

3'-6

" T

O 4

'-0

"

2"

4"

10

1

2

"

22.5°

22.5°

2"

4"

10

1

2

"

1 12" TEE WITH (3) 4" RETURN NOZZLES TO BE SET 10" BELOW WATER LINE TO TOP RETURN

1

2

2

ROTATE PUMP RETURN TEE AS NEEDED TO MEET RETURN PIPING ANGLE

STRAIGHT RETURN PIPE WITH ACCELERATOR NOZZLE IS TO BE SET 10" BELOW WATER LINE TO

TOP OF PIPE

3

PLACE PUMP AND 90° SUCTION FITTING AT APPROPRIATE HEIGHT TO MEET RETURN PIPING

ELEVATION. DRY FIT ALL PIPING FOR PROPER FIT AND ALIGNMENT BEFORE GLUEING IN PLACE.

SUCTION PIPING TO 90° ELBOW IS TO BE PIPED USING ONLY FACTORY FITTINGS SUCH AS 11.25°,

22.5°, 45°, 90° ELBOWS AS NEEDED.

4

DRY FIT ALL PIPING FROM RETURN TO PUMP & FROM PUMP TO SUCTION BOXES BEFORE

GLUEING IN PLACE.

5

6

6

33.0°

1

4

7

.0

°

4

5

.

0

°

4

'

-

0

"

4

'

-

0

"

1

12" TEE WITH

(3) 4" RETURN NOZZLE

2

44

3 3

7

7

7

POUR 3' X 3' X 4" THICK SLAB 2" BELOW BOTTOM FLANGE FOR PUMP SUPPORT PAD.6

7

7

3'-0

" T

O 4

'-0

"

3'-6

" T

O 4

'-0

"

5

5

55

5

5

55

3" DRAIN LINE

TO FRENCH DRAIN

OR DRAINFIELD

3" DRAIN LINE

TO FRENCH DRAIN

OR DRAINFIELD

3" DRAIN LINE

TO FRENCH DRAIN

OR DRAINFIELD

3" DRAIN LINE

TO FRENCH DRAIN

OR DRAINFIELD

4

4

12" TEE WITH

(3) 4" RETURN NOZZLE

10" OR 12" PIPE RETURN WITH

ACCELERATOR NOZZLE

NOTE: BOLTS AND NUTS

MUST NOT PROTRUDE

INTO CONCRETE. ALLOW

CLEARANCE FOR REMOVAL

NOTE: BOLTS AND NUTS

MUST NOT PROTRUDE

INTO CONCRETE. ALLOW

CLEARANCE FOR REMOVAL

NOTE: BOLTS AND NUTS

MUST NOT PROTRUDE

INTO CONCRETE. ALLOW

CLEARANCE FOR REMOVAL

NOTE: BOLTS AND NUTS

MUST NOT PROTRUDE

INTO CONCRETE. ALLOW

CLEARANCE FOR REMOVAL

CONSTRUCTION GUIDE

LAZY RIVER PUMP SYSTEM

PAGE

2 OF 7

REFER TO IMAGE 5 ON PG. 4

REFER TO IMAGE 2 & 4 ON PG. 4

REFER TO IMAGE

2 & 4 ON PG. 4

REFER TO IMAGE

3 ON PG. 4

REFER TO IMAGE

3 ON PG. 4

10" OR 12" SCH 40 PVC PIPE

RETURN WITH ACCELERATOR NOZZLE

10" OR 12" SCH 40 PVC

PIPE RETURN

12" SCH 40 PVC PIPE

SUCTION LINE

12" SCH 40 PVC PIPE

SUCTION LINE

12" SCH 40 PVC

PIPE RETURN

Page 3: RETURN WITH ACCELERATOR NOZZLE LAZY RIVER 3 LAZY RIVER CON DOC.pdf · 3determine suction drain location and pipe routing and angle from suction ... lazy river pump system page 7 of

TYPICAL COMPONENTS

CONSTRUCTION GUIDE

LAZY RIVER PUMP SYSTEM

PAGE

TOP

FRONT SIDE

DUAL SUCTION

GUNITE

APPLICATION

FRONT SIDE

TOP

12 X 5

ACCLERATOR

NOZZLE

10 X 4

ACCLERATOR

NOZZLE

FRONT BACK

TOP

12" TEE

WITH (3) 4"

RETURNS

TOP

FRONT SIDE

VARIABLE SPEED

DRIVE

TOP

FRONT SIDE

VARIABLE SPEED

DRIVE COVER

IN PIPE

IN PIPE

OF 73

RIVERFLOW PUMP

REFER TO IMAGE

1,3,5 ON PG. 4

REFER TO IMAGE

3 ON PG. 4

REFER TO IMAGE

2,4,5 ON PG. 4

Page 4: RETURN WITH ACCELERATOR NOZZLE LAZY RIVER 3 LAZY RIVER CON DOC.pdf · 3determine suction drain location and pipe routing and angle from suction ... lazy river pump system page 7 of

TYPICAL COMPONENTS

CONSTRUCTION GUIDE

LAZY RIVER PUMP SYSTEM

PAGE

OF 74

1 2

34

5

5

Page 5: RETURN WITH ACCELERATOR NOZZLE LAZY RIVER 3 LAZY RIVER CON DOC.pdf · 3determine suction drain location and pipe routing and angle from suction ... lazy river pump system page 7 of

TYPICAL COMPONENTS

CONSTRUCTION GUIDE

LAZY RIVER PUMP SYSTEM

PAGE

OF 75

1 2

4

5

3

Page 6: RETURN WITH ACCELERATOR NOZZLE LAZY RIVER 3 LAZY RIVER CON DOC.pdf · 3determine suction drain location and pipe routing and angle from suction ... lazy river pump system page 7 of

WATER LINE

VERTICAL PUMP INSTALLATION

SCALE N.T.S.

CRITICAL NOTE:

THIS SYSTEM IS A FLOODED SUCTION SYSTEM. TO MAINTAIN FLOODED SUCTION

PUMP INSTALLATION MUST ADHERE TO MAXIMUM HEIGHT IN RELATION TO

WATER LINE.

VERTICAL INSTALLATION:

PUMP FLANGE GASKET MUST MEET MAXIMUM HEIGHT AT WATER LINE OR

LOWER. PIPE FITTINGS ARE REQUIRED TO MAINTAIN RETURN @ 10" BELOW

WATER LEVEL. REFER TO SECTIONS AND PLANS FOR PUMP ELEVATION AND

REQUIRED FITTINGS AS PER PROJECT APPLICATION.

12" SCH 40

SUCTION PIPE

FROM MAIN

DRAIN BOXES

RIVER

BEAM

10" OR 12" SCH 40

RETURN PIPE

TYPICAL COMPONENTS

CONSTRUCTION GUIDE

LAZY RIVER PUMP SYSTEM

PAGE

OF 76

MAXIMUM PUMP

HEIGHT WITH TOP

OF BOTTOM

FLANGE AT OR

BELOW WATER

LINE

Page 7: RETURN WITH ACCELERATOR NOZZLE LAZY RIVER 3 LAZY RIVER CON DOC.pdf · 3determine suction drain location and pipe routing and angle from suction ... lazy river pump system page 7 of

CONCRETE PUMP BASE

CONSTRUCTION GUIDE

LAZY RIVER PUMP SYSTEM

PAGE

OF 77

CRITICAL DIMENSION TOP OF PIPE BELOW WATER LINE

PATIO OR DECK PATIO OR DECK

2"

4"

T.B

.D

.2

"

1'-0" 1'-0"

2'-0"

4" 4"

CRITICAL DIMENSION TOP OF PIPE BELOW WATER LINE

2"

4"

T.B

.D

.2

"

SWIM POOL 5" BELOW WATER LINE

LAZY RIVER 10" BELOW WATER LINE

PUMP IS TO BE SET PER TOP OF PIPE

REQUIREMENTS. NOTE: PUMP MAY

BE BELOW WATER LINE USING

FITTINGS TO ELEVATE RETURN PIPE

TO PIPE DEPTH REQUIREMENTS.

1'-0" 1'-0"

2'-0"

4"

4"

CAP / COPING STONES

2" ABOVE GRADE

3" DRAIN LINE TO WASTE

MAXIMUM PUMP HEIGHT (WATER LINE AT TOP OF BOTTOM FLANGE)

CAST IN PLACE

CONCRETE PUMP BASE

ALLOW 2" CLEARANCE BETWEEN

BOTTOM FOR FLANGE BOLT

ACCESS.

12" 90° ELBOW

12" X 10" REDUCING

BUSHING

BUSHING

12" 90° ELBOW

12" X 10" REDUCING

3" DRAIN LINE TO APPROVED

SEWER OR FRENCH DRAIN

SWIM POOL 5" BELOW WATER LINE

LAZY RIVER 10" BELOW WATER LINE

PUMP IS TO BE SET PER TOP OF PIPE

REQUIREMENTS. NOTE: PUMP MAY

BE BELOW WATER LINE USING

FITTINGS TO ELEVATE RETURN PIPE

TO PIPE DEPTH REQUIREMENTS.

10" or 12" SCH 40 PVC

RETURN PIPE

12" SCH 40 PVC

SUCTION PIPE

10" or 12" SCH 40 PVC

RETURN PIPE

12" SCH 40 PVC

SUCTION PIPE