6
F47 FILTRATION Return Line Filter RF014-RF130 Technical Data Technical Data STAUFF RF 014-130 return line filters are designed as tank top filters. They are mounted directly on the tank top and when 100% of the system’s oil is filtered, they provide the optimum removal of contaminant from the system. This provides the pump with clean oil thus reducing contaminant generated wear. The filter bowl or funnel is designed to return the oil beneath the surface thus preventing the entrainment of air by the returning oil. By-pass valve Opening pressure (integrated in the 3 bar ± 0,3 bar filter element) (43.5 PSI ± 4.35 PSI) other pressures on request Clogging indicator Gauge type indicator 0…4 bar (0…58 PSI) colored segments; Electrical switch, setting 2.5 bar (36.25 PSI) Filter elements Specification see page F52 Media Mineral oils, other fluids on request Technical Specification Construction Tank Top flange mounting Filter head Aluminium Filter bowl Glass fiber reinforced polyamide Seals NBR (Buna-N ® ), FPM (Viton ® ) or EPDM (Ethylene-Propylene) Threaded connection BSP, NPT- and SAE-“O“-Ring thread as well as SAE-flange 3000 PSI Operating pressure max 16 bar (232 PSI) Proof pressure 24 bar (350 PSI) Temperature Range -10 to +100°C (14° to 212ºF) Clogging Indicator (optional) Housing Cover Filter Head Flange Seal Filter Element with integrated By-pass Valve Filter Bowl

Return Line Filter RF014-RF130 Technical DataReturn Line Filter RF014-RF130 Technical Data Technical Data STAUFF RF 014-130 return line filters are designed as tank top filters. They

  • Upload
    others

  • View
    12

  • Download
    0

Embed Size (px)

Citation preview

  • F47

    FILTR

    AT

    ION

    Return Line Filter RF014-RF130 Technical Data

    Technical Data

    STAUFF RF 014-130 return line filters

    are designed as tank top filters. They are

    mounted directly on the tank top and

    when 100% of the system’s oil is filtered,

    they provide the optimum removal of

    contaminant from the system. This

    provides the pump with clean oil thus

    reducing contaminant generated

    wear. The filter bowl or funnel is designed

    to return the oil beneath the surface

    thus preventing the entrainment of air

    by the returning oil.

    By-pass valve Opening pressure (integrated in the 3 bar ± 0,3 barfilter element) (43.5 PSI ± 4.35 PSI) other pressures on request

    Clogging indicator Gauge type indicator 0…4 bar (0…58 PSI) colored segments; Electrical switch, setting 2.5 bar (36.25 PSI)

    Filter elements Specification see page F52

    Media Mineral oils, other fluids on request

    Technical Specification

    Construction Tank Top flange mounting

    Filter head Aluminium

    Filter bowl Glass fiber reinforced polyamide Seals NBR (Buna-N®), FPM (Viton®) or EPDM (Ethylene-Propylene)

    Threaded connection BSP, NPT- and SAE-“O“-Ring thread as well as SAE-flange 3000 PSI

    Operating pressure max 16 bar (232 PSI)

    Proof pressure 24 bar (350 PSI)

    Temperature Range -10 to +100°C (14° to 212ºF)

    Clogging Indicator(optional)

    Housing Cover

    Filter Head

    Flange Seal

    Filter Element withintegrated By-pass Valve

    Filter Bowl

  • F48

    FILT

    RA

    TIO

    N

    Return Line Filter RF014-RF130 Dimensions

    Dimensions RF 014-130

    Dimensions Return Line Filters

    Flange Connection

    Mounting Detail

    Threaded Outlet

    Dimensions in mm (inch)

    (5.51)

    (8.27)

    (7.09)

    (9.45)

    (9.25)

    (6.2)

    (8.88)

    (8.11)

    (10.51)

    (10.77)

    (3.6)

    (6.3)

    (4.69)

    (7.09)

    (6.79)

    h5 h6 l1 G2 G3 G4

    23,5

    140 48

    G1

    M6

    (0.93) 210 (1.89) or 1 NPT

    24 180

    66

    G11/4 M8 (0.95) 240 (2.6) or 11/4"NPT

    27

    235 85

    G11/2

    1/2

    M10

    (1.06) 315 (3.35) or 11/2"NPT

    UNC

    (12.4)

    x15 (x0.59)

    Thread Connection G Dimensions

    Filter SAE- “O” SAE Size

    BSP

    NPT Ring Flange b1 b2 b3 b4 b5 b6 d1 d2 d3 d4 d5 h1 h2 h3 h4

    Thread 3000 PSI

    RF014 G 3/4 3/4" 11/16-12 UN -

    89 80 73 57,5 36 100 78 33 66

    91,5 157,5

    RF030 G 1 1" 15/16-12 UN (3.5) (3.15) (2.87) (2.26) (1.42) (3.94) (3.07) (1.3) (2.6) 159,5 225,5

    RF045 G 11/4 11/4" 15/8-12 UN -

    120 110 100 84 48 135 105 41 86 119 206

    RF070 G 11/2 11/2" 17/8-12 UN (4.72) (4.33) (3.94) (3.31) (1.89) (5.14) (4.13) (1.61) (3.39) 180 267

    RF090 G 2 2" 17/8-12 UN

    150 135 88 102 42,9 77,8 126 112,5 54,5 170 131 47 98 172,5 273,5

    RF130 G 2 2" 17/8-12 UN

    2" (5.91) (5.14) (3.47) (4.02) (1.69) (3.06) (4.96) (4.43) (2.15) (6.69) (5.16) (1.85) (3.86) 252,5 353,5

    (9.49) (13.92)

    Standard position for clogging indicator

    Position 1

    Position 2

    h4

    h2

    h1h3

    h5

    G

    d1d2d3

    h6R

    emov

    al C

    lear

    ance

    b1

    squa

    re

    b2

    squa

    re

    l1

    G4

    d5

    d4

    G2

    h5

    G3

    b3

    b5

    b4

    b6

    or 1/4"UNC

    or 5/16"UNC

    or 3/8"UNC

  • F49

    FILTR

    AT

    ION

    Return Line Filter RF014-RF130 Options

    ø D L Thread SW G

    SRV-114-B16 RF 014/030 60 (2.36) 139 (5.47) G 1 or 1" NPT 46 (1.81)

    SRV-200-B20 RF 045/070 82 (3.23) 139 (5.47) G 11/4 or 11/4" NPT 60 (2.36)

    SRV-227-B24 RF 090/130 82 (3.23) 200 (7.87) G 11/2 or 11/4" NPT 60 (2.36)

    Options RF 014-130

    1. Visual clogging indicator HI-M The gauge visually displays the degree of contamination of the element. The colored segments allow quick visual checking.

    green 0...2.5 bar (0…36.25 PSI) Element has service life left yellow 2.5...3.0 bar (36,25 ...43.5 PSI) Element is contaminated and should be changed red >3.0 bar (>43.5 PSI) By-pass valve open, unfiltered oil passing to tank

    Visual clogging indicator

    2. Electrical clogging switch HI-G The switch is used where an electrical signal is needed to indicate when the element needs changing. The switch can turn on a light, or shut the machine down, or any further function controlled by an electric signal. The switching pressure is 2,5 bar (36,25 PSI) and this allows the element to be changed before the by-pass setting of 3 bar (43,5 PSI) is reached.

    Maximum Voltage Switch Type 42 V HI-G 42 110 V HI-G 110 220 V HI-G 220

    Electrical Clogging Switch

    3. Leakage oil connection Seal or case drain lines can be connected to the filter through either of the clogging indicator ports providing that the leakage oil can accept a pressure of 3 bar (43.5 PSI). It ensures that no un-filtered oil can return to the reservoir. It may save the cost of a manifold.

    Leakage oil connection

    4. Filter bowl with threaded connection

    Under some circumstances such as a tall reservoir or one with oil levels which vary greatly during operation, it is necessary to extend the filter bowl so that the returning oil returns beneath the surface and does not entrain air in the process. The optional bowl with a female thread allows an extension to be fitted quite simply.

    Threaded outlet

    5. Filter bowl with threaded connection and diffuser

    Diffusers mounted to the filter bowl minimize foaming and reduce noise of high return line flows. For further details on STAUFF diffusers please refer to the “Hydraulic Accessories” section of this catalog.

    SizeSRV

    for Return Line

    Filter Size

    Dimensions

    Threaded outlet with SRV

    Dimensions in mm (inch)

    M10x1 keg.

    G

    SW

    øD

    L

    SW 24

    G 1/4 or1/4" NPT

    reducedto ø 26(ø1.02)

    9

    ˜72,

    5

    (SW 0.95)

    (0.3

    5)

    (2.8

    5)Dimension G2 see table page F48

    ø40

    vkt.14

    M10x1 or1/8” NPT

    (1.58)

    (0,3

    9)(0

    .69)

    (1.7

    5)

    (vkt.0,51)

    1017

    ,544

    ,5

    0

    12

    3

    bar

    G2

  • F50

    FILT

    RA

    TIO

    N

    Return Line Filter RF014-RF130 Ordering Code

    Ordering Code Filter Housings

    RE-014 G 10 V /X

    Clogging indicator Pos.*(see page F49)

    M Pressure gaugeG42 Electrical switch 42 V

    1 2G110 Electrical switch 110 VG220 Electrical switch 220 V* Position of clogging indicator see page F48without any code: assembly in the middle of the filter cover

    Ordering Code Filter Elements

    Series RE

    Group

    according to filter housing

    Connection style Group

    Code Connection style 014 030 045 070 090 130

    B BSP G3/4 G1 G11/4 G11/2 G2 G2

    B 1 BSP G1/2 G

    1/2 G11/2 G1

    1/4 G11/4 G1

    1/4

    B 2 BSP G1 G3/4 – – G1

    1/2 G11/2

    N NPT 3/4" 1" 1

    1/4" 11/2" 2" 2"

    N 1 NPT 1" 3/4" 1

    1/2" 11/4" 1

    1/2" 11/2"

    U SAE-“O“-Ring thread 11/16 15/16 15/8 17/8 1

    7/8 17/8

    U 1 SAE-“O“-Ring thread 15/16 11/16 17/8 15/8 1

    5/8 15/8

    F SAE-flange – – – – 2" 2" (3000 PSI) Flanges are not supplied.

    Group

    Size Flow

    l/min GPM 014 60 14 030 110 30 045 160 45 070 240 70 090 330 90 130 500 130

    For Complete Filters:

    identification filter material+ micron rating code(see ordering code filter elements below)

    Design Code

    only for information

    Seal Material

    B NBR (Buna-N®) V FPM (Viton®) E EPDMother seal material on request

    Micron Rating

    03 3 µm 05 5 µm 10 10 µm 20 20 µm 25 25 µm 50 50 µm 100 100 µm 200 200 µmother micron ratings on request

    Seal Material

    B NBR (Buna-N®) V FPM (Viton®) E EPDMother seal materials on request

    RF 070 ... B / B / M / G / L1 /X

    Outlet Style

    O Standard outlet (without thread) G Filter bowl with threaded outlet* Note Exact flow will depend on filter

    element selected. Consult technical data on page F51 & F52

    Design Code

    only for information

    Filter Material

    Code Material max ∆p*collapse A Stainless fiber 30 bar (435 PSI) N Filter paper 16 bar (232 PSI) G Inorganic glass fiber 30 bar (435 PSI) S, B Stainless mesh 30 bar (435 PSI)

    *collapse / burst resistance as per ISO 2941

    Micron ratingsavailable

    03, 05, 10, 20

    25, 50, 100, 200

    Bold type identifies preferred material, other filter materi-als or micron ratings on request

    Filter Type RF

    Additional Features Pos.*

    L Leakage oil connection 1 2

    * Position of leakage oil connection see page F48without any code: assembly in the middle of the filter cover

  • F51

    FILTR

    AT

    ION

    Return Line Filter RF014-RF130 Flow Characteristics

    0.1

    0.08

    0.06

    0.04

    0.02

    0.0

    1.5

    1.2

    0.9

    0.6

    0.3

    0

    Flow Characteristics of Return Line Filters RF 014-130The following characteristics are valid for mineral oils with a density of 0,85 kg/dm3 and the kinematic viscosity of 30 mm2/s. The characteristics have been determined in accordance to ISO 3968. Multipass filter ratings have been obtained in accordance to ISO 16889. Consult factory for details.

    Housings RF014/030

    0 25 50 75 100 125

    0 5 10 15 20 25 30

    0.5

    0.4

    0.3

    0.2

    0.1

    0.0

    7.5

    6

    4.5

    3

    1.5

    0

    ∆p in

    bar

    ∆p in

    PSI

    ∆p in

    bar

    ∆p in

    PSI

    ∆p in

    bar

    ∆p in

    PSI

    ∆p in

    bar

    ∆p in

    PSI

    ∆p in

    bar

    ∆p in

    PSI

    ∆p in

    bar

    ∆p in

    PSI

    ∆p in

    bar

    ∆p in

    PSI

    ∆p in

    bar

    ∆p in

    PSI

    ∆p in

    bar

    ∆p in

    PSI

    ∆p in

    bar

    ∆p in

    PSI

    ∆p in

    bar

    ∆p in

    PSI

    Housings RF045/070

    0 50 100 150 200 250

    0 12.5 25 37.5 50 62.5

    0.5

    0.4

    0.3

    0.2

    0.1

    0.0

    7.5

    6

    4.5

    3

    1.5

    0

    Filter ElementsRE...S

    0% 20% 40% 60% 80% 100% 120%

    Filter ElementsRE...N

    0% 20% 40% 60% 80% 100% 120%

    0.1

    0.08

    0.06

    0.04

    0.02

    0.0

    1.5

    1.2

    0.9

    0.6

    0.3

    0

    Housings RF090/130

    0 100 200 300 400 500

    0 25 50 75 100 125

    0.5

    0.4

    0.3

    0.2

    0.1

    0.0

    7.5

    6

    4.5

    3

    1.5

    0

    Filter Elements RE014A

    0 10 20 30 40 50 60

    0 2.5 5 7.5 10 12.5 15

    0.5

    0.4

    0.3

    0.2

    0.1

    0.0

    A10

    A20

    A03 A057.5

    6

    4.5

    3

    1.5

    0

    Filter Elements RE070A

    0 40 80 120 160 200 240

    0 10 20 30 40 50 60

    0.5

    0.4

    0.3

    0.2

    0.1

    0.0

    A10

    A20

    N10

    N20S25

    S50

    S100

    Q as a percentage of the nominal flow

    Q in l/min

    Q in US GPM

    Q in l/min

    Q in US GPM

    Q in l/min

    Q in US GPM

    Q in l/min

    Q in US GPM

    Q in l/min

    Q in US GPM

    Q in l/min

    Q in US GPM

    Q in l/min

    Q in US GPM

    Q in l/min

    Q in US GPM

    Q in l/min

    Q in US GPM

    Q as a percentage of the nominal flow

    A03 A057.5

    6

    4.5

    3

    1.5

    0

    Filter Elements RE030A

    0 20 40 60 80 100 120

    0 5 10 15 20 25 30

    0.5

    0.4

    0.3

    0.2

    0.1

    0.0

    A10

    A20

    A03 A057.5

    6

    4.5

    3

    1.5

    0

    Filter Elements RE130A

    0 100 200 300 400 500

    0 25 50 75 100 125

    0.5

    0.4

    0.3

    0.2

    0.1

    0.0

    A10

    A20

    A03

    A057.5

    6

    4.5

    3

    1.5

    0

    Filter Elements RE090A

    0 110 220 330

    0 30 60 90

    0.5

    0.4

    0.3

    0.2

    0.1

    0.0

    A10

    A20

    A03

    A057.5

    6

    4.5

    3

    1.5

    0

    Filter Elements RE045A

    0 40 80 120 160

    0 10 20 30 40

    0.5

    0.4

    0.3

    0.2

    0.1

    0.0

    A10A20

    A03 A057.5

    6

    4.5

    3

    1.5

    0

  • F52

    Return Line Filter RF014-RF130 Flow Characteristics

    FILT

    RA

    TIO

    N

    37.5

    30

    22.5

    15

    7.5

    0

    37.5

    30

    22.5

    15

    7.5

    0

    Flow Characteristics of Return Line Filters RF014-130The following characteristics are valid for mineral oils with a density of 0,85 kg/dm3 and the kinematic viscosity of 30mm2/s. The characteristics have been determined in accordance to ISO 3968. Multipass filter ratings have been obtained in accordance to ISO 16889. Consult factory for details.

    Filter Elements RE014G

    0 10 20 30 40 50 60

    0 2.5 5 7.5 10 12.5 15

    2.5

    2.0

    1.5

    1.0

    0.5

    0.0

    G10

    G20

    G03

    G05

    37.5

    30

    22.5

    15

    7.5

    0

    37.5

    30

    22.5

    15

    7.5

    0

    37.5

    30

    22.5

    15

    7.5

    0

    37.5

    30

    22.5

    15

    7.5

    0

    Q in l/min

    Q in US GPM

    Q in l/min

    Q in US GPM

    Q in l/min

    Q in US GPM

    Filter Elements RE030G

    0 20 40 60 80 100 120

    0 5 10 15 20 25 30

    2.5

    2.0

    1.5

    1.0

    0.5

    0.0

    G10

    G20

    G03

    G05

    Filter Elements RE045G

    0 40 80 120 160

    0 10 20 30 40

    2.5

    2.0

    1.5

    1.0

    0.5

    0.0

    G10

    G20

    G03

    G05

    Filter Elements RE070G

    0 40 80 120 160 200 240

    0 10 20 30 40 50 60

    2.5

    2.0

    1.5

    1.0

    0.5

    0.0

    G10

    G20

    Q in l/min

    Q in US GPM

    Q in l/min

    Q in US GPM

    Q in l/min

    Q in US GPM

    G03 G05

    Filter Elements RE130G

    0 100 200 300 400 500

    0 25 50 75 100 125

    2.5

    2.0

    1.5

    1.0

    0.5

    0.0

    G05

    G10

    G20

    G03

    Filter Elements RE090G

    0 110 220 330

    0 30 60 90

    2.5

    2.0

    1.5

    1.0

    0.5

    0.0

    G03

    G05

    G10

    G20

    ∆p in

    bar

    ∆p in

    PSI

    ∆p in

    bar

    ∆p in

    PSI

    ∆p in

    bar

    ∆p in

    PSI

    ∆p in

    bar

    ∆p in

    PSI

    ∆p in

    bar

    ∆p in

    PSI

    ∆p in

    bar

    ∆p in

    PSI

    YellowBack: YellowNext: