4
Edwards Protection Cannulae Retrograde Cardioplegia Catheters MAXIMIZE MYOCARDIAL PROTECTION A growing body of evidence points to combined retrograde and antegrade cardioplegia as the best approach for maximizing myocardial protection in patients undergoing arrested heart procedures. 1-5 Edwards retrograde cardioplegia catheters are specifically designed to help you protect your patients during on-pump cardiac surgery by maximizing myocardial protection. Edwards retrograde cardioplegia catheters offer a variety of features designed to meet various surgical needs and preferences. Proprietary ergonomic handle provides an anatomically precise path during placement

Retrograde Cardioplegia Catheters - Edwards Lifesciencesht.edwards.com/scin/edwards/eu/sitecollectionimages/products/cardiaccannulae/...smooth balloon configurations. accommodate a

  • Upload
    others

  • View
    4

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Retrograde Cardioplegia Catheters - Edwards Lifesciencesht.edwards.com/scin/edwards/eu/sitecollectionimages/products/cardiaccannulae/...smooth balloon configurations. accommodate a

Edwards Protection Cannulae

RetrogradeCardioplegia Catheters

MAXIMIZE MYOCARDIAL PROTECTIONA growing body of evidence points to combined retrogradeand antegrade cardioplegia as the best approach formaximizing myocardial protection in patients undergoingarrested heart procedures.1-5

Edwards retrograde cardioplegia catheters are specificallydesigned to help you protect your patients during on-pumpcardiac surgery by maximizing myocardial protection.

Edwards retrograde cardioplegia catheters offer a varietyof features designed to meet various surgical needs andpreferences.

Proprietary ergonomichandle provides an

anatomically precise pathduring placement

AR05171_EDW_Spec_Cardio_Retro_1.qxd:Layout 1 6/21/10 3:47 PM Page 2

Page 2: Retrograde Cardioplegia Catheters - Edwards Lifesciencesht.edwards.com/scin/edwards/eu/sitecollectionimages/products/cardiaccannulae/...smooth balloon configurations. accommodate a

SELF-INFLATING BALLOONEdwards retrograde cardioplegia catheters are available in a self-inflating balloon style, which offersthe convenience of automatic balloon inflation when retrograde cardioplegia is delivered.

Balloon Styles: Balloon Sizes:Available in textured and Multiple balloon sizes ranging from 9 mm to 20 mm tosmooth balloon configurations. accommodate a variety of patient sizes and surgical preferences.

RetrogradeCardioplegia Catheters

Multiple handle and styletoptions to accommodate a variety

of surgical preferences

* Shorter length† Female luer instead of stopcock

Smoothballoon

Texturedballoon

Pre-shapedstylet and

handle

Hourglasshandle andguidewire

styletGuidewirestylet

SPECIFICATIONSCATHETER SIZE 9 FR 12 FR 14 FRBALLOON STYLE Smooth Textured Textured SmoothBALLOON SIZE 9 mm 18 mm 14 mm 18 mm 20 mm 18 mm 20 mmRETENTION Conventional Retractaguard Conventional Retractaguard Conventional Retractaguard Conventional Conventional ConventionalTECHNOLOGY technology technology technologyPRE-SHAPED RC09 RC2012 RC014IT RC2014 RC014T RC2014LB NPC014T RC014 NPC014STYLET AND RC2014S* RC2014LBS*HANDLEGUIDEWIRE RC09M RC2012M - RC2014M RC014MT RC2014LBM - RC014M -STYLET ISP3031†

HOURGLASS - - - ISP3098 - - - - -HANDLE ANDGUIDEWIRESTYLETH

AN

DLE

CON

FIG

URA

TIO

NS

AR05171_EDW_Spec_Cardio_Retro_1.qxd:Layout 1 6/21/10 3:47 PM Page 3

Page 3: Retrograde Cardioplegia Catheters - Edwards Lifesciencesht.edwards.com/scin/edwards/eu/sitecollectionimages/products/cardiaccannulae/...smooth balloon configurations. accommodate a

MANUALLY INFLATING BALLOONEdwards retrograde cardioplegia catheters are available in a manually inflating balloon style,which offers surgeon control over inflating and deflating the balloon.

Balloon Styles: Body Styles:Available in textured and smooth Available in polyurethane or wire-reinforcedballoon configurations silicone configurations

RETRACTAGUARDTECHNOLOGYThis proprietary technology is designed to help thecannula retain its shape after deployment in thepatient and to help prevent balloon slippage,particularly during posterior graftingprocedures.

† Female luer instead of stopcock

Retractaguardtechnology

HA

ND

LECO

NFI

GU

RATI

ON

S

SPECIFICATIONSCATHETER SIZE 12 FR 14 FRBALLOON STYLE Textured Textured SmoothBODY STYLE Polyurethane Polyurethane Wire-reinforced silicone Wire-reinforced siliconeRETENTION Retractaguard Retractaguard Conventional ConventionalTECHNOLOGY technology technologyPRE-SHAPED RC2012MIBB RC2014MIBB SRT014MIBB RC014MIBBSTYLET ANDHANDLEGUIDEWIRE RC2012MIB RC2014MIB SRT014MIB RC014MIBSTYLET PLD014MIBH†

HOURGLASS - - - ISP3039HANDLE ANDGUIDEWIRESTYLET

Smoothballoon

AR05171_EDW_Spec_Cardio_Retro_1.qxd:Layout 1 6/21/10 3:48 PM Page 4

Page 4: Retrograde Cardioplegia Catheters - Edwards Lifesciencesht.edwards.com/scin/edwards/eu/sitecollectionimages/products/cardiaccannulae/...smooth balloon configurations. accommodate a

Edwards Lifesciences LLC | www.edwards.com

Irvine, USA | Nyon, Switzerland | Tokyo, Japan | Singapore, Singapore | Sao Paulo, Brazil |

References:1. Buckberg Gd. Antegrade/Retrograde Blood Cardioplegia to Ensure Cardioplegic Distribution: Operative Techniques

and Objectives. J Card Surg 1989;4(3):216-238.2. Loope Fd, Higgens Tl, Panda R, et al. Myocardial Protection During Cardiac Operations. J Thorac Cardiovasc Surg

1992;104:608-618.3. Buckberg Gd. Myocardial Protection: An Overview. Semin In Thorac Cardiovasc Surg 1993;5(2):98-106.4. Borger MA, Rao V, Weisel RD, et al. Reoperative coronary bypass surgery: Effect of patent grafts and retrograde

cardioplegia. J Thorac Cardiovasc Surg 2001;121:83-90.5. RangarajAT, et al. Real-time visualization and quantification of retrograde cardioplegia delivery using near infrared

fluorescent imaging. J Card Surg 2008;23(6):701-8.

CAUTION: Federal (USA) law restricts this device to sale by or on the order of a physician.See instructions for use for full prescribing information.

Edwards, Edwards Protection Cannulae and Retractaguard are trademarks of Edwards Lifesciences Corporation. EdwardsLifesciences and the stylized E logo are trademarks of Edwards Lifesciences Corporation and are registered in theUnited States Patent and Trademark Office. © 2010 Edwards Lifesciences LLC. All rights reserved. AR05171

0

10

20

30

40

50

60

0 50 100 150 200 250 300

Pres

sure

Dro

p(m

mH

g)

Flow Rate (ml/min), H2O at Room Temperature

Retrograde Cardioplegia CatheterPressure Drop vs. Flow

14 Fr. Self-Inflating,Retractaguard technology

9 Fr. Self-Inflating,Conventional

12 Fr. Self-Inflating,Retractaguard technology

14 Fr. Self-Inflating,Conventional

14 Fr. Manually Inflating,Conventional

12 Fr. Manually Inflating,Retractaguard technology

14 Fr. Manually Inflating,Retractaguard technology

RetrogradeCardioplegia Catheters

AR05171_EDW_Spec_Cardio_Retro_1.qxd:Layout 1 6/21/10 3:46 PM Page 1