Resumen API 650_spa
Citation preview
TITULO
Standard cubic feet per hourDensidad del acero
Process Piping: piping typically found in petroleum refineries; chemical, pharmaceutical, textile, paper, semiconductor, and cryogenic plants; and related processing plants and terminals
Pipeline Transportation Systems for Liquid Hydrocarbons and Other Liquids: piping transporting products that are predominately liquid between plants and terminals and within terminals, pumping, regulating, and metering stations
Gas Transportation and Distribution Piping Systems: piping transporting products that are predominately gas between sources and terminals, including compressor, regulating, and metering stations; and gas gathering pipelines
PUNTOS A TENER EN CUENTA DURANTE LA INSPECCIÓN BAJO ASME 650 12th 2013Shell Casco - Espesores de casco sección 5 - Shell design, párrafo 5.6.1.1
Bottom Fondo
Roof Techo
Frangile Roof Techo fágil / Techo de unión débil
Shell Attachments and Tank Appurtenances
General General
Roof Manhole Manhole de techo
Flanged roof nozzles Conexiones bridadas de techo
Threaded roof nozzles Conexiones roscadas de techo
Rectangular Roof Openings Manhole rectangular en el techo
Water Drawoff Sumps SumideroScaffold-Cable Support Soporte de línea de vida Figure 5.22
Threaded Connections Conexiones roscadas
Grounding lugs Platinas de aterramiento
Platforms, Walkways, and StairwaysRoof venting Venteo de techo API2000
- Espesores de fondo sección 5 – bottom plates, párrafo 5.4.1 "All bottom plates shall have a corroded thickness of not less than 6 mm"
- Espesores de techo sección 5 – roofs, párrafo 5.10.2.2 "Roof plates shall have a nominal thickness of not less than 5 mm (3/16 in.) or 7-gauge sheet"
El borde de las soldadura de los accesorios permanentes deberán ser al menos a 75 mm (3") de las juntas horizontales del casco y al menos a 15 mm (6") de las juntas verticales.
Figure 5.16 and Table 5.13a and Table 5.13bFigure 5.19 and Table 5.14a and Table 5.14bFigure 5.20 and Table 5.15a and Table 5.15bFigure 5.17 and Figure 5.18 and/or this sectionFigure 5.21 and Table 5.16a and Table 5.16b
Conexiones de tuberías roscadas deberán ser hembras y cónicas. Rosca según ASME B1.20.1.
- Mínimo 4 unidades,- El espaciamiento lug máximo sugerido es de 30 m (100 pies).- De acero inoxidable austenítico.- No debe pintarse.Figure 5.23
Table 5.17, Table 5.18, Table 5.19a, and Table 5.19b