12
www.vdw-dental.com RECIPROC ® Results of scientific studies Endo Easy Efficient ® one file endo

Results of scientific studies...Canal shaping Resistance to fracture one reason for instrument fracture is cyclic fatigue which is caused by the repeated tension and compression of

  • Upload
    others

  • View
    2

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Results of scientific studies...Canal shaping Resistance to fracture one reason for instrument fracture is cyclic fatigue which is caused by the repeated tension and compression of

www.vdw-dental.com

RECIPROC® Results of scientific studies

Endo Easy Efficient®

one file endo

Page 2: Results of scientific studies...Canal shaping Resistance to fracture one reason for instrument fracture is cyclic fatigue which is caused by the repeated tension and compression of

Preparation with RECIPROC®

3-year outcome 4

How safe is RECIPROC®?

Canal shaping 5Resistance to fracture 5Microcracks 6 Extrusion 7

How efficient is RECIPROC®? Cleaning efficiency in the apical region 8 in oval canals 8 during retreatment 9

Is RECIPROC® time saving? Preparation time 10 Preparation without hand filing 11 Retreatment time 11

Content

Page 3: Results of scientific studies...Canal shaping Resistance to fracture one reason for instrument fracture is cyclic fatigue which is caused by the repeated tension and compression of

PREPaRation with RECiPRoC® Tried and tested – Millions of treatments have been performed with RECiPRoC® since its introduction in 2011. one file endo, the innovative concept for root canal preparation is growing worldwide. Renowned scientists have put the RECiPRoC® system to the test and have come to the following conclusion:

RECiPRoC® is safe, efficient and time saving.

RECIPROCaTE and smIlE

Try it out

and see!

Dr. Bjørn Besserman-svendsen, Frederiksberg Copenhagen, Denmark

“My experience with RECiPRoC® has been nothing short of amazing. this presents a paradigm shift in the way mechanical root canal preparation can be achieved to provide every practitioner a markedly better opportunity to produce consistent, predic- table results. RECiPRoC® provides the safest and easiest method for shaping the canals compared to any system. if this doesn’t get you more excited about endodontics nothing will!“

Page 4: Results of scientific studies...Canal shaping Resistance to fracture one reason for instrument fracture is cyclic fatigue which is caused by the repeated tension and compression of

PREPaRatIOn wItH RECIPROC®

3-year outcome of endodontically treated teeth*

1 Yared G. a 3-year outcome of endodontic treatments done with the RECiPRoC® single file canal preparation system. Published by VDw. august 13, 2012.

RECiPRoC® enables successful endo-treatments.1

4

successfully healed not healed

*All treatments were performed by one endodontist in a private practice.

80%

90%

100%

60%

70%

40%

50%

30%

20%

10%

0% Init

ial t

reat

men

t

wit

hout

ap

ical

dis

ease

(n

=17

7)

97.18%

Init

ial t

reat

men

tw

ith

apic

al d

isea

se

(n=

202)

93.07%

Ret

reat

men

t (n

=10

7)

91.59%

Page 5: Results of scientific studies...Canal shaping Resistance to fracture one reason for instrument fracture is cyclic fatigue which is caused by the repeated tension and compression of

Compared to another single file system, the RECiPRoC® instrument showed a significantly higher resistance to cyclic fatigue (time period until fracture: RECiPRoC® 130.8 seconds versus single file system 97.8 seconds).4

HOw saFE Is RECIPROC®?

Canal shaping

Resistance to fracture

one reason for instrument fracture is cyclic fatigue which is caused by the repeated tension and compression of the instrument, for example in a canal curvature.

Furthermore!

2 Bürklein S, hinschitza K, Dammaschke t, Schäfer E. Shaping ability and cleaning effectiveness of two single-file systems in severely curved root canals of extracted teeth: RECiPRoC and waveone versus Mtwo and Protaper. iEJ 2012, 45: 449-461, doi: 10.1111/j. 1365-2591.2011.01996.x. 3 Gavini G, Caldeira CL, akisue E, de Miranda Candeiro Gt, Sacaguti Kawakami Da. Resistance to flexural fatigue of RECiPRoC R25 files under continuous rotation and reciprocating movement. JoE 2012, 38 (5): 684-687.4 Plotino G, Grande nM, testarelli L, Gambarini G. Cyclic fatigue of RECiPRoC and waveone reciprocating instruments. iEJ 2012, 45 (7): 614-618, doi: 10.1111/j.1365-2591.2012.02015.x.

sec.

400

300

350

163 sec.

357 sec.

200

250

150

100

50

0

R25, time until instrument fractures

in r

ecip

roca

tio

n

in c

ont

inuo

usro

tatio

n

5

the RECiPRoC® instrument maintains the original root canal curvature well.2

the RECiPRoC® R25 in reciprocation has a signi- ficantly higher resistance to cyclic fatigue than in continuous rotation.3

Page 6: Results of scientific studies...Canal shaping Resistance to fracture one reason for instrument fracture is cyclic fatigue which is caused by the repeated tension and compression of

the RECiPRoC® instrument causes significantly less microcracks compared to another single and multiple file system.6

microcracks

numerous tests show that endodontic procedures may cause undesirable mechanical damages in dentine.5

5 Rödig t. Mechanische Schädigung des wurzelkanaldentins durch endodontische Maßnahmen. Literatur-Rundschau 2012, 21 (1): 1-7. 6 Liu R, hou XB, wesselink PR, wu MK, Shemesh h. the incidence of root microcracks caused by 3 different single-file systems versus the Protaper system. JoE 2013, 39 (8): 1054-1056.

80%

90%

100%

60%

70%

40%

50%

30%

20%

10%

0% mul

tip

le fi

le

syst

em

50%

sing

le fi

le

syst

em

65%

RE

CIP

RO

95%

Microcracks

in the apical surface and horizontal section

only in the horizontal section

no microcracks

only in the apical surface

6

Page 7: Results of scientific studies...Canal shaping Resistance to fracture one reason for instrument fracture is cyclic fatigue which is caused by the repeated tension and compression of

Extrusion

after preparation with RECiPRoC®, the degree of inflammation (e.g. Substance P values) in the perio- dontal ligament is almost identical to that of a healthy, untreated tooth.7

no significant inflammatory reaction in the apical region due to the extrusion of debris during preparation with RECiPRoC®.8

7,8 Caviedes-Bucheli J, Moreno Jo, Carreño CP, Delgado R, Garcia DJ, Solano J, Diaz E, Munoz hR. the effect of single-file reciprocating systems on substance P and calcitonin gene-related peptide expression in human periodontal ligament. iEJ 2013, 46: 419-426, doi: 10.1111/iej.12005.

7

0.8

0.9

0.6

1.2

0.7

1.3

0.5

1.1

0.4

0.3

0.1

1.0

0.2

0

Concentration of Substance P (SP)

*   periodontal ligament (PL)

pmol

SP

per m

g of

PL*

RE

CIP

RO

heal

thy

toot

h

0.511

1.220

0.453

sing

le fi

le s

yste

m

0.908

hand

inst

rum

ents

Page 8: Results of scientific studies...Canal shaping Resistance to fracture one reason for instrument fracture is cyclic fatigue which is caused by the repeated tension and compression of

RECiPRoC® cleans the root canal system significantly more thoroughly, especially in the apical region, com- pared with other systems.9

RECiPRoC®’s ability to signi- ficantly reduce the amount of bacteria in oval canals is equivalent to that of a multiple file system.10

9 Bürklein S, hinschitza K, Dammaschke t, Schäfer E. Shaping ability and cleaning effectiveness of two single-file systems in severely curved root canals of extracted teeth: RECiPRoC and waveone versus Mtwo and Protaper. iEJ 2012, 45: 449-461, doi: 10.1111/j. 1365-2591.2011.01996.x. 10 alves FRF, Rôças in, almeida BM, neves MaS, Zoffoli J, Siqueira JF. Quantitative molecular and culture analyses of bacterial elimination in oval-shaped root canals by a single-file instrumentation technique. iEJ 2012, 45 (9): 871-877, doi: 10.1111/iej.12085.

Cleaning efficiency in the apical region

Cleaning efficiency in oval canals

HOw EFFICIEnT Is RECIPROC®?

8

4

3

2

low

am

ount

of d

ebris

resi

due

in c

anal

h

igh

amou

nt o

f deb

ris re

sidu

e in

can

al

1

RE

CIP

RO

C® R

25

2.45

mtw

o® 3

0/.0

5

2.50

sing

le fi

le s

yste

m

3.05

mul

tip

le fi

le s

yste

m

3.35

0

Page 9: Results of scientific studies...Canal shaping Resistance to fracture one reason for instrument fracture is cyclic fatigue which is caused by the repeated tension and compression of

During retreatment, RECiPRoC® removes gutta-percha and sealer the most effectively.11

9

Cleaning efficiency during retreatment

10%

12%

14%

6%

8%

4%

2%

0%

Gutta­‐percha­and­sealer­residue

RE

CIP

RO

4.57%

7.19%

12.17%

hand

inst

rum

ents

and

Gat

esG

lidd

en

Ret

reat

men

t in

stru

men

tsw

11 Zuolo aS, Mello Jr JE, Cunha RS, Zuolo ML, Bueno CES. Efficacy of reciprocating and rotary techniques for removing filling material during root canal retreatment. iEJ 2013, first published online: 18 march 2013, doi: 10.1111/iej.12085.

Page 10: Results of scientific studies...Canal shaping Resistance to fracture one reason for instrument fracture is cyclic fatigue which is caused by the repeated tension and compression of

RECiPRoC® prepares a root canal up to 60% faster than multiple file systems.12

Is RECIPROC® TImE savInG?

Preparation time

12 Bürklein S, hinschitza K, Dammaschke t, Schäfer E. Shaping ability and cleaning effectiveness of two single-file systems in severely curved root canals of extracted teeth: RECiPRoC and waveone versus Mtwo and Protaper. iEJ 2012, 45: 449-461, doi: 10.1111/j.1365-2591.2011.01996.x.

10

Preparation timesec.

160

180

200

120

140

80

100

60

40

50

0 RE

CIP

RO

73.1 sec.

mul

tip

le fi

le s

yste

ms

185.2 sec.

Page 11: Results of scientific studies...Canal shaping Resistance to fracture one reason for instrument fracture is cyclic fatigue which is caused by the repeated tension and compression of

without having to create an initial glide path, RECiPRoC® reached full working length of more than 93% of the examined cases.13

in comparison to other systems, the RECiPRoC®

instrument removes gutta-percha and sealer the most quickly.15

Preparation without hand filing

Retreatment time

13,14 De-Deus G, arruda tEP, Souza EM, neves a, Magalhães K, thuanne E, Fidel RaS. the ability of the Reciproc R25 instrument to reach the full root canal working length without a glide path. iEJ 2013, first published online: 6 april 2013, doi: 10.1111/iej.12091. 15 Zuolo aS, Mello Jr JE, Cunha RS, Zuolo ML, Bueno CES. Efficacy of reciprocating and rotary techniques for removing filling material during root canal retreatment. iEJ 2013, first published online: 18 march 2013, doi: 10.1111/iej.12085.

11

Cases in which working length was achievedwith RECIPROC®

reached working length

80%

100%

60%

40%

20%

0%

96.44%

stra

ight

ro

ot

cana

ls (n

=25

3)90.66%

slig

htly

cur

ved

ro

ot

cana

ls (n

=24

9)

in cases in which the iSo size 10 hand file did not reach the full working length (after preparing to 2/3 of the estimated working length), the R25 was able to reach full working length in 67.3% of the cases!14

Furthermore!

did not reach working length

Page 12: Results of scientific studies...Canal shaping Resistance to fracture one reason for instrument fracture is cyclic fatigue which is caused by the repeated tension and compression of

www.RECiPRoC.com

vDW GmbH Bayerwaldstr. 15 • 81737 Munich • Germany Tel. +49 89 62734-0 • Fax +49 89 62734-304 www.vdw-dental.com • [email protected]

one file endo

Vw

0003

48

R

ev. 0

/05.

09.1

3