13
Residential Solutions New Square D QO ‘All-in- one’ & ‘Stand-alone’ Generator Panels Offer - 2011

Residential Solutions New Square D QO ‘All-in-one’ & ‘Stand-alone’ Generator Panels Offer - 2011

Embed Size (px)

Citation preview

Page 1: Residential Solutions New Square D QO ‘All-in-one’ & ‘Stand-alone’ Generator Panels Offer - 2011

Residential Solutions

New Square D QO ‘All-in-one’ & ‘Stand-alone’ Generator Panels

Offer - 2011

Page 2: Residential Solutions New Square D QO ‘All-in-one’ & ‘Stand-alone’ Generator Panels Offer - 2011

QO ‘all-in-one’ Generator Panel Launch

Product Offer

Page 3: Residential Solutions New Square D QO ‘All-in-one’ & ‘Stand-alone’ Generator Panels Offer - 2011

Schneider Electric 3- Canadian Residential Solutions – 2011

Residential Strategy

Schneider Electric’s new QO Service Entrance ‘All-in-one’ Generator Panel combines a service entrance loadcentre with emergency power switching capabilities

60A 3-pole utility/generator circuit breakers switch both line & neutral conductors in accordance with the Canadian Electrical Code

Ideally suited for residential, rural, commercial and light industrial applications requiring a quick and easy switchover from utility power to standby generator power

Page 4: Residential Solutions New Square D QO ‘All-in-one’ & ‘Stand-alone’ Generator Panels Offer - 2011

Schneider Electric 4- Canadian Residential Solutions – 2011

Customer Benefits

Features Benefits

Single enclosure with pre-wired loadcentre and generator circuit breakers

‘All-in-One’

Factory installed 200A Main Breaker, 22kAIC

Provides enhanced fault current protection

Accepts up to 40 standard or 80 QO tandem circuits in total

Ample wiring provision for the average application

Accepts up to 18 standard or 36 QO tandem circuits to feed critical loads

Improved critical load circuit capacity

Backed-out neutral and ground screws

Reduced installation time

Page 5: Residential Solutions New Square D QO ‘All-in-one’ & ‘Stand-alone’ Generator Panels Offer - 2011

Schneider Electric 5- Canadian Residential Solutions – 2011

Residential Strategy

Schneider Electric’s new QO ‘Stand-alone’ Generator Panels are designed for use with bonded or un-bonded generators

30 & 60A 3-pole utility/generator circuit breakers switch both line & neutral conductors in accordance with the Canadian Electrical Code

Ideally suited for residential, rural, commercial applications requiring a quick and easy switchover from utility power to standby generator power

Page 6: Residential Solutions New Square D QO ‘All-in-one’ & ‘Stand-alone’ Generator Panels Offer - 2011

Schneider Electric 6- Canadian Residential Solutions – 2011

Features Benefits

Ample wiring provision for the average application

Accepts up to 18 standard or 36 QO tandem circuits to feed

critical loads

rotating interlock bracket Patented design that ensures only one power source is available

Factory installed for use with bonded generators

Provides for the most common generator grounding connection

Easily converts for use with un-bonded generators

Accommodates ungrounded generator connections

All Generator panel components factory installed

Reduced installation time

Customer Benefits

Page 7: Residential Solutions New Square D QO ‘All-in-one’ & ‘Stand-alone’ Generator Panels Offer - 2011

Schneider Electric 7- Canadian Residential Solutions – 2011

Key Selling Features

●Installation Speed●Backed out slot/robbie neutral & ground bars

●Safety●Shielded bus design minimizes exposed bus

●Quality●Qwik-open ‘visi-trip’ branch circuit breakers●22kAIC Main Breakers provide fault current protection

●Innovation●Patented rotating interlock bracket

Page 8: Residential Solutions New Square D QO ‘All-in-one’ & ‘Stand-alone’ Generator Panels Offer - 2011

Schneider Electric 8- Canadian Residential Solutions – 2011

Canadian QO Generator Panels

Safety

Shielded bus

provide protection

against accidental live contact

Page 9: Residential Solutions New Square D QO ‘All-in-one’ & ‘Stand-alone’ Generator Panels Offer - 2011

Schneider Electric 9- Canadian Residential Solutions – 2011

Canadian QO Generator Panels

Innovation

Patented rotating interlock bracket

Page 10: Residential Solutions New Square D QO ‘All-in-one’ & ‘Stand-alone’ Generator Panels Offer - 2011

Schneider Electric 10- Canadian Residential Solutions – 2011

Canadian QO Generator Panels

Installation SpeedBacked out slot/Robertson neutral and ground bars

Page 11: Residential Solutions New Square D QO ‘All-in-one’ & ‘Stand-alone’ Generator Panels Offer - 2011

Schneider Electric 11- Canadian Residential Solutions – 2011

Canadian QO Generator Panels

Quality

Qwik-open ‘visi-trip’ branch circuit breakers

22kAIC Main Breakers provide fault current protection

Page 12: Residential Solutions New Square D QO ‘All-in-one’ & ‘Stand-alone’ Generator Panels Offer - 2011

Canadian QO Generator Panels

Catalogue

Number

Product

Code

UPC

Code

Line

Code

PD Cat

PD Sched

QOGP3P604436200 94839 785901948391 C123 37551 SLC

QOGP3P3036 91493 785901914938 C123 37553 SLC

QOGP3P6036 37725 785901377252 C123 37553 SLC

D1130SM1101EP R0

Page 13: Residential Solutions New Square D QO ‘All-in-one’ & ‘Stand-alone’ Generator Panels Offer - 2011

Schneider Electric 13- Canadian Residential Solutions – 2011

Building Your Sales Argument