Request for Lighting Calculation Killark is proud to offer Lighting Layouts to better assist customers with their lighting upgrades. The lighting request sheet assists lighting designers with speed and accuracy for the layout. Please complete the Lighting Request sheet as accurately as possible (the accuracy of the request sheet will ensure that the layout meets expectations).

Request for Lighting Calculation - hubbellcdn.com for Lighting Calculation. Killark is proud to offer Lighting Layouts to better assist customers with their lighting upgrades. The

Embed Size (px)

Citation preview

Page 1: Request for Lighting Calculation - hubbellcdn.com for Lighting Calculation. Killark is proud to offer Lighting Layouts to better assist customers with their lighting upgrades. The

Request for Lighting Calculation

Killark is proud to offer Lighting Layouts to better assist customers

with their lighting upgrades. The lighting request sheet assists lighting

designers with speed and accuracy for the layout. Please complete

the Lighting Request sheet as accurately as possible (the accuracy of

the request sheet will ensure that the layout meets expectations).

Page 2: Request for Lighting Calculation - hubbellcdn.com for Lighting Calculation. Killark is proud to offer Lighting Layouts to better assist customers with their lighting upgrades. The

Request for Lighting Calculation

FITTINGS • ENCLOSURES • DISTRIBUTION EQUIPMENT • PLUGS & RECEPTACLES • CONTROLS • LIGHTING FIXTURESHKFRM-LITCALC 03-17 © Killark, 2017

Hubbell KillarkHubbell Incorporated (Delaware)

3940 Dr. Martin Luther King Dr. • St. Louis, MO 63113Phone: (314) 531-0460 • Fax: (314) 531-7164

www.hubbell-killark.com

To: Killark ApplicationsPlease provide the following information:

Date:

City:

Location:

Hazardous Location Rating:

Light Source:

Wattage:

From:

Requested By:

Company:

Distributor:

Address:

City:

State: Zip:

Contact:

Fixture Catalog Number:

Room Dimensions: feet metersLength:

Width:

Height:(floor to ceiling)

Work Plane Height:(use 2.5 feet if not specified)

Mounting Height:(floor to fixture)

Additional Requirements:

Sent With Drawings: None Cad PDFDrawings are required to be marked up to show the location of the lighting layout

Reflectances:Ceiling:

Walls:

Floor:

Illumination Required:

Light Loss Factor:(maintenance factor)

Note:

1.Reflectancesmaybeestimatedasfollowsifnotprovidedbythecustomer.Anextremelylightcoloredceilingcanbeassumedtohaveareflectanceof80%,mediumrangecoloringwoulduse50%,andextremelydarkceilingwouldusea10%value.Inthecaseofwallreflectances,use50%forbrightwalls,30%formediumwalls,and10%fordarkwalls.

2.ForinitialilluminationuseaLightLossFactorof1.00;formaintainedilluminationsthefollowingLightLossFactorsmaybeused:

Metal Halide Pulse .80Metal Halide .75High Pressure Sodium .80Mercury Vapor .75Fluorescent .75LED .90