Regulatory Division West Permits Branch Fort Myers Permits Section SAJ-1990-40367 (GP-EPL) Ehab Guirguis Lee County Facilities Construction and Management 1500 Monroe Street Fort Myers, FL 33901 Dear Mr. Guirguis: Your application for a Department of the Army permit received on 24 October 2019 has been assigned number SAJ-1990-40367. A review of the information and drawings provided shows the proposed work is the replacement of an existing 3020SF dilapidated public fishing pier which has been condemned for public safety. The existing pier will be completely removed and the proposed pier will be placed in the same footprint as the existing. The project will result in the installation of seventy-six 14square concrete pilings. The project would affect waters of the United States associated within Matlacha Pass and is located in Section 24, Township 44 South, Range 22 East, at 4577 Pine Island Road NW, Lee County, Florida Your project, as depicted on the enclosed drawings (Attachment I), is authorized by Nationwide Permit (NWP) 3. The authorization of NWP 3 is valid until March 18, 2022. Please access the Corps' Jacksonville District Regulatory Division Internet page to view the special and general conditions for NWP-3, which apply specifically to these authorizations. The Internet URL address is: http://www.saj.usace.army.mil/Missions/Regulatory.aspx Please be aware this Internet address is case sensitive; and, you will need to enter it exactly as it appears above. Once there you will need to click on “Source Book”; and, then click on “Nationwide Permits.” Then you will need to click on the specific NWP permits noted above. You must comply with all of the special and general conditions of the permit; and, any project-specific conditions noted below, or you may be subject to enforcement action. The following special conditions are included with these authorizations and are to ensure compliance with the federal permit and to minimize impacts to the aquatic environment: 1. Reporting Address: The Permittee shall submit all reports, notifications, documentation and correspondence required by the general and special conditions of this permit to either (not both) of the following addresses: DEPARTMENT OF THE ARMY JACKSONVILLE DISTRICT CORPS OF ENGINEERS 1520 Royal Palm Square Blvd, Suite 310 Fort Myers, FL 33919 December 5, 2019 REPLY TO ATTENTION OF

REPLY TO ATTENTION OF ATTACHMENT B Documents/Matlacha F… · Fort Myers Permits Section SAJ-1990-40367 (GP-EPL) Ehab Guirguis Lee County Facilities Construction and Management 1500

  • Upload
    others

  • View
    2

  • Download
    0

Embed Size (px)

Citation preview

Page 1: REPLY TO ATTENTION OF ATTACHMENT B Documents/Matlacha F… · Fort Myers Permits Section SAJ-1990-40367 (GP-EPL) Ehab Guirguis Lee County Facilities Construction and Management 1500

Regulatory Division West Permits Branch Fort Myers Permits Section SAJ-1990-40367 (GP-EPL) Ehab Guirguis Lee County Facilities Construction and Management 1500 Monroe Street Fort Myers, FL 33901 Dear Mr. Guirguis: Your application for a Department of the Army permit received on 24 October 2019 has been assigned number SAJ-1990-40367. A review of the information and drawings provided shows the proposed work is the replacement of an existing 3020SF dilapidated public fishing pier which has been condemned for public safety. The existing pier will be completely removed and the proposed pier will be placed in the same footprint as the existing. The project will result in the installation of seventy-six 14” square concrete pilings. The project would affect waters of the United States associated within Matlacha Pass and is located in Section 24, Township 44 South, Range 22 East, at 4577 Pine Island Road NW, Lee County, Florida

Your project, as depicted on the enclosed drawings (Attachment I), is authorized by Nationwide Permit (NWP) 3. The authorization of NWP 3 is valid until March 18, 2022.

Please access the Corps' Jacksonville District Regulatory Division Internet page to view the special and general conditions for NWP-3, which apply specifically to these authorizations. The Internet URL address is:

http://www.saj.usace.army.mil/Missions/Regulatory.aspx Please be aware this Internet address is case sensitive; and, you will need to enter it exactly as it appears above. Once there you will need to click on “Source Book”; and, then click on “Nationwide Permits.” Then you will need to click on the specific NWP permits noted above. You must comply with all of the special and general conditions of the permit; and, any project-specific conditions noted below, or you may be subject to enforcement action.

The following special conditions are included with these authorizations and are to ensure compliance with the federal permit and to minimize impacts to the aquatic environment: 1. Reporting Address: The Permittee shall submit all reports, notifications, documentation and correspondence required by the general and special conditions of this permit to either (not both) of the following addresses:

DEPARTMENT OF THE ARMY

JACKSONVILLE DISTRICT CORPS OF ENGINEERS

1520 Royal Palm Square Blvd, Suite 310

Fort Myers, FL 33919

December 5, 2019

REPLY TO

ATTENTION OF

jonesdw
Typewritten Text
ATTACHMENT B
Page 2: REPLY TO ATTENTION OF ATTACHMENT B Documents/Matlacha F… · Fort Myers Permits Section SAJ-1990-40367 (GP-EPL) Ehab Guirguis Lee County Facilities Construction and Management 1500

-2-

a. For electronic mail (preferred): [email protected] (not to exceed 15 MB). b. For standard mail: U.S. Army Corps of Engineers, Regulatory Division, Enforcement Section, P.O. Box 4970, Jacksonville, FL 32232-0019. The Permittee shall reference this permit number, SAJ-1990-40367 (NW-EPL), on all submittals. 2. Self-Certification: Within 60 days of completion of the work authorized by this permit, the Permittee shall complete the attached “Self-Certification Statement of Compliance” form and submit it to the Corps (Attachment II). In the event that the completed work deviates in any manner from the authorized work, the Permittee shall describe the deviations between the work authorized by this permit and the work as constructed on the “Self-Certification Statement of Compliance” form. The description of any deviations on the “Self-Certification Statement of Compliance” form does not constitute approval of any deviations by the Corps. 3. Commencement Notification: Within 10 days from the date of initiating the work authorized by this permit the Permittee shall submit a completed “Commencement Notification” Form (Attachment III). 4. Assurance of Navigation and Maintenance: The Permittee understands and agrees that, if future operations by the United States require the removal, relocation, or other alteration, of the structures or work herein authorized, or if in the opinion of the Secretary of the Army or his authorized representative, said structure or work shall cause unreasonable obstruction to the free navigation of the navigable waters, the Permittee will be required, upon due notice from the Corps of Engineers, to remove, relocate, or alter the structural work or obstructions caused thereby, without expense to the United States. No claim shall be made against the United States on account of any such removal or alteration. 5. Jacksonville District Programmatic Biological Opinion (JAXBO), November 2017, Project Design Criteria (PDCs): Structures authorized under this permit must comply with all applicable PDCs, based on the permitted activity, as required by JAXBO. Please note that failure to comply with the applicable PDCs, where a take of listed species occurs, would constitute an unauthorized take, and noncompliance with this permit. The NMFS is the appropriate authority to enforce the terms and conditions of JAXBO. The most current version of

Page 3: REPLY TO ATTENTION OF ATTACHMENT B Documents/Matlacha F… · Fort Myers Permits Section SAJ-1990-40367 (GP-EPL) Ehab Guirguis Lee County Facilities Construction and Management 1500

-3-

JAXBO can be accessed at the Jacksonville District Regulatory Division internet webpage in the Endangered Species section of the Sourcebook located at: http://www.saj.usace.army.mil/Missions/Regulatory/SourceBook.aspx Note - JAXBO may be subject to revision at any time. The most recent version

of these conditions must be utilized during the design and construction of the permitted work. In accordance with the Endangered Species Act, and for those projects which do not comply with JAXBO, the Corps will seek individual consultation with the NMFS. Note - some authorized activities may deviate from the PDCs. In cases, where

the activity (i.e., structure dimensions, length, etc.) deviates from the PDCs, the permit drawings shall supersede the PDCs. For each of the following authorized activities subject of this permit, the permittee shall adhere to the following PDCs, which are attached to, and made part of, this authorization/verification letter (Attachment IV): Activity 2 - Pile-supported Structures and Anchored Buoys: (AP.1-14; A2.1-16) 6. Manatee Conditions: The Permittee shall abide by the enclosed standard

construction conditions designed to protect the endangered West Indian manatee, 2011 (Attachment V). 7. Posting of Permit: The Permittee shall have available and maintain for review

a copy of this permit and approved plans at the construction site. 8. Daylight Hours: All activities must be completed during daylight hours. 9. Agency Changes/Approvals: Should any other agency require and/or approve changes to the work authorized or obligated by this permit, the Permittee is advised a modification to this permit instrument is required prior to initiation of those changes. It is the Permittee’s responsibility to request a modification of this permit from the Fort Myers Permits Section. The Corps reserves the right to fully evaluate, amend, and approve or deny the request for modification of this permit. 10. Educational Signs: signs must be posted in a visible location(s), alerting users of listed species in the area susceptible to vessel strikes and hook-and-line captures. The most current version of the signs that must be downloaded and sign installation guidance are available at:

Page 4: REPLY TO ATTENTION OF ATTACHMENT B Documents/Matlacha F… · Fort Myers Permits Section SAJ-1990-40367 (GP-EPL) Ehab Guirguis Lee County Facilities Construction and Management 1500

-4-

(http://sero.nmfs.noaa.gov/protected_resources/section_7/protected_species_educational_signs/index.html). The signs required to be posted by area are stated below:

All projects in Florida shall use the Save Sea Turtle, Sawfish, and Dolphin sign. These signs shall include contact information to the sea turtle and marine mammal stranding networks and smalltooth sawfish encounter database. 11. Monofilament Recycling Bins: All commercial and public boat ramps also must install and maintain for the life of the facility monofilament recycling bins to reduce the risk of turtle or sawfish entanglement in or ingestion of marine debris. Monofilament recycling bins must: a. Be constructed and labeled according to the instructions provided at http://mrrp.myfwc.com b. Be maintained for the life of the facility in working order and emptied frequently so that they do not overflow. 12: Turbidity Barriers: Prior to the initiation of any of the work authorized by

this permit, the Permittee shall install floating turbidity barriers with weighted skirts that extend to within 1 foot of the bottom around all work areas that are in, or adjacent to, surface waters. The turbidity barriers shall remain in place and be maintained until the authorized work has been completed and all suspended and erodible materials have been stabilized. Turbidity barriers shall be removed upon stabilization of the work area. 13. Historic Properties:

a. No structure or work shall adversely affect impact or disturb properties listed in the National Register of Historic Places (NRHP) or those eligible for inclusion in the NRHP. b. If during the ground disturbing activities and construction work within the permit area, there are archaeological/cultural materials encountered which were not the subject of a previous cultural resources assessment survey (and which shall include, but not be limited to: pottery, modified shell, flora, fauna, human remains, ceramics, stone tools or metal implements, dugout canoes, evidence of structures or any other physical remains that could be associated with Native American cultures or early colonial or American settlement), the Permittee shall immediately stop all work and ground-disturbing activities within a 100-meter diameter of the discovery and notify the Corps within the same business day (8 hours). The Corps shall then notify the Florida State Historic Preservation Officer

Page 5: REPLY TO ATTENTION OF ATTACHMENT B Documents/Matlacha F… · Fort Myers Permits Section SAJ-1990-40367 (GP-EPL) Ehab Guirguis Lee County Facilities Construction and Management 1500

-5-

(SHPO) and the appropriate Tribal Historic Preservation Officer(s) (THPO(s)) to assess the significance of the discovery and devise appropriate actions. c. Additional cultural resources assessments may be required of the permit area in the case of unanticipated discoveries as referenced in accordance with the above Special Condition ; and if deemed necessary by the SHPO, THPO(s), or Corps, in accordance with 36 CFR 800 or 33 CFR 325, Appendix C (5). Based, on the circumstances of the discovery, equity to all parties, and considerations of the public interest, the Corps may modify, suspend or revoke the permit in accordance with 33 CFR Part 325.7. Such activity shall not resume on non-federal lands without written authorization from the SHPO for finds under his or her jurisdiction, and from the Corps. d. In the unlikely event that unmarked human remains are identified on non-federal lands, they will be treated in accordance with Section 872.05 Florida Statutes. All work and ground disturbing activities within a 100-meter diameter of the unmarked human remains shall immediately cease and the Permittee shall immediately notify the medical examiner, Corps, and State Archeologist within the same business day (8-hours). The Corps shall then notify the appropriate SHPO and THPO(s). Based, on the circumstances of the discovery, equity to all parties, and considerations of the public interest, the Corps may modify, suspend or revoke the permit in accordance with 33 CFR Part 325.7. Such activity shall not resume without written authorization from the State Archeologist and from the Corps.

This authorization does not include conditions that would prevent the ‘take’ of a state-listed fish or wildlife species. These species are protected under sec. 379.411, Florida Statutes, and listed under Rule 68A-27, Florida Administrative Code. With regard to fish and wildlife species designated as species of special concern or threatened by the State of Florida, you are responsible for coordinating directly with the Florida Fish and Wildlife Conservation Commission (FWC). You can visit the FWC license and permitting webpage (http://www.myfwc.com/license/wildlife/) for more information, including a list of those fish and wildlife species designated as species of special concern or threatened. The Florida Natural Areas Inventory (http://www.fnai.org/) also maintains updated lists, by county, of documented occurrences of those species.

This authorization does not give absolute Federal authority to perform the work as specified on your application. The proposed work may be subject to local building restrictions mandated by the National Flood Insurance Program. You should contact your local office that issues building permits to determine if your site is located in a flood-prone area, and if you must comply with the local building requirements mandated by the National Flood Insurance Program.

Page 6: REPLY TO ATTENTION OF ATTACHMENT B Documents/Matlacha F… · Fort Myers Permits Section SAJ-1990-40367 (GP-EPL) Ehab Guirguis Lee County Facilities Construction and Management 1500

-6-

If you are unable to access the internet or require a hardcopy of any of the conditions, limitations, or expiration date for the above referenced NWP, please contact Eric Larrat by telephone at 239-334-1975. Thank you for your cooperation with our permit program. The Corps’ Jacksonville District Regulatory Division is committed to improving service to our customers. We strive to perform our duty in a friendly and timely manner while working to preserve our environment. We invite you to complete our automated Customer Service Survey at http://corpsmapu.usace.army.mil/cm_apex/f?p=regulatory_survey. Please be aware this Internet address is case sensitive; and, you will need to enter it exactly as it appears above. Your input is appreciated – favorable or otherwise. Sincerely,

Eric P. Larrat Project Manager

Enclosures Attachment I: Project Drawings Attachment II: Self-Certification Statement of Compliance Form Attachment III: Commencement Notification Form Attachment IV: Project Design Criteria (PDCs) for In-Water Activities Attachment V: Manatee In-Water Work Conditions

Page 7: REPLY TO ATTENTION OF ATTACHMENT B Documents/Matlacha F… · Fort Myers Permits Section SAJ-1990-40367 (GP-EPL) Ehab Guirguis Lee County Facilities Construction and Management 1500

GENERAL CONDITIONS 33 CFR PART 320-330

1. The time limit for completing the work authorized ends on the dates identified in the letter. 2. You must maintain the activity authorized by this permit in good condition and in conformance with the terms and conditions of this permit. You are not relieved of this requirement if you abandon the permitted activity, although you may make a good faith transfer to a third party in compliance with General Condition 4 below. Should you wish to cease to maintain the authorized activity or should you desire to abandon it without a good faith transfer, you must obtain a modification of this permit from this office, which may require restoration of the area. 3. If you discover any previously unknown historic or archeological remains while accomplishing the activity authorized by this permit, you must immediately notify this office of what you have found. We will initiate the Federal and state coordination required to determine if the remains warrant a recovery effort or if the site is eligible for listing in the National Register of Historic Places. 4. If you sell the property associated with this permit you must obtain the signature of the new owner in the space provided and forward a copy of the permit to this office to validate the transfer of this authorization. 5. If a conditioned water quality certification has been issued for your project, you must comply with the conditions specified in the certification as special conditions to this permit. For your convenience, a copy of the certification is attached if it contains such conditions. 6. You must allow a representative from this office to inspect the authorized activity at any time deemed necessary to ensure that it is being or has been accomplished in accordance with the terms and conditions of your permit.

Page 8: REPLY TO ATTENTION OF ATTACHMENT B Documents/Matlacha F… · Fort Myers Permits Section SAJ-1990-40367 (GP-EPL) Ehab Guirguis Lee County Facilities Construction and Management 1500

ATTACHMENT I

Page 9: REPLY TO ATTENTION OF ATTACHMENT B Documents/Matlacha F… · Fort Myers Permits Section SAJ-1990-40367 (GP-EPL) Ehab Guirguis Lee County Facilities Construction and Management 1500

TH

E

OF

FI

CI

AL

RE

CO

RD

OF

THI

S

SH

EE

T I

S

TH

E

EL

EC

TR

ONI

C

FI

LE

DI

GI

TA

LL

Y

SI

GN

ED

AN

D

SE

AL

ED

UN

DE

R

RU

LE 61

G15-23.004,

F.

A.

C.

SDS 6/19

CLH 6/19

RMW 6/19

VAZ 6/19REGISTRY NO. 27559

FORT MYERS, FL 33901

SUITE 200

2121 MCGREGOR BOULEVARD

HIGHSPANS ENGINEERING, INC.

P.E. LICENSE NUMBER 60524

VINCENT ZALIAUSKAS, P.E.

40

Feet

0 10

REF. DWG. NO.

SHEET NO.

SHEET TITLE:

PROJECT NAME:

DRAWN BY:

CHECKED BY:

DESIGNED BY:

CHECKED BY:

ROAD NO. COUNTY PROJECT NO.

REVISIONS

DATE BY DESCRIPTION DATE BY DESCRIPTION

LEE

Sabrina 10/11/2019 12:32:25 PM H:\_Project18\1812_MatlachaPier\struct\AERIAL_11x17.DGN

CONSTRUCTION & MANAGEMENT

LEE COUNTY FACILITIES

AERIAL VIEW

73'-2"

23'-7"

39'-7"

10'-0"

SIDEWALK

CONCRETE

LEGEND

MANGROVE FRINGE

OPEN WATER

SAND & MUD

SAND & MUD

APPROXIMATE MHW = 1.14'

UPLANDS

UPLANDS

COVERAGE 5-10%

(Halodule wrightii)Shoalgrass

APPROXIMATE MEAN HIGH WATER (MHW)

MANGROVE FRINGE

& GRAVITY WALL

27'-6" RAMP

16'-0"183'-6"

(TOTAL PILES = 76)

14" SQ. CONCRETE PILES (TYP.)

TOTAL AREA = 103.4 SF

NO. PILES = 76

AREA 14" SQ. PILES = 1.36 SF

PROPOSED CONCRETE PILES:

TOTAL AREA = 44.0 SF

NO. PILES = 80

AREA 10" DIA. PILES = 0.55 SF

EXISTING TIMBER PILES:

TOTAL PROJECT AREA = 3020 SF

MATLACHA FISHING PIER REPLACEMENT

Page 10: REPLY TO ATTENTION OF ATTACHMENT B Documents/Matlacha F… · Fort Myers Permits Section SAJ-1990-40367 (GP-EPL) Ehab Guirguis Lee County Facilities Construction and Management 1500

25

36

PINELAND

Demere Ldg.

Underhill

Pt.

Thirsting

Lake

Tom Black

Lake

Buzzard

Bay

Demere Ldg.

Underhill

Pt.

Cr.

Rock

Cr.

Pine

Cr.

Island

Underhill

Cr.

TRANQUILITY BAY

AIRPORT

(PVT)

Chiquita

Boulevard

Cape

Maria Dr.

Burnt

McCARDLE IS.

INDIAN

FIELD

PUMPKIN

KEY

LITTLE

PINE

ISLAND

WEST

IS.

PORPOISE

POINT IS.

BEAR

KEY

DEER

KEY

LANIER KEY

BEN

COLEMAN

KEYS

DEER

STOP

KEYS

P I

N

E

MATLACHA

Lower 36

Bay

Upper 36

Bay

Pontoon

Bay

Pass

Matlacha

MATLACHA

PASS

AQUATIC

PRESERVE

Hole

Mud

The

234

9 11

21 22 23

26272829

32 3334

35

3

9

10

1516

WP

S

B

PINELAND

765

78

78

CP

78

8 9

1617

7

18

282930

3132

33

456

8 97

12

13

20 2119

R-2

3-E

R-2

2-E

R-2

3-E

R-2

2-E

TH

E

OF

FI

CI

AL

RE

CO

RD

OF

THI

S

SH

EE

T I

S

TH

E

EL

EC

TR

ONI

C

FI

LE

DI

GI

TA

LL

Y

SI

GN

ED

AN

D

SE

AL

ED

UN

DE

R

RU

LE 61

G15-23.004,

F.

A.

C.

T-44-S

T-45-S

T-44-S

T-45-S

CHARLOTTE COUNTY

ON ANY ELECTRONIC COPIES.

AND THE SIGNATURE MUST BE VERIFIED

NOT CONSIDERED SIGNED AND SEALED

PRINTED COPIES OF THIS DOCUMENT ARE

ON THE DATE ADJACENT TO THE SEAL

SIGNED AND SEALED BY

THIS ITEM HAS BEEN DIGITALLY

STATE OF

� � �

No 60524

SA

K

SUAILAZ TNEC

NIV

RE

ENI

GNE LANOISS

E

FO

RP

ADIROL

F

ESNECIL

SHEET DESCRIPTION

EXPRESSWAY

TU

RNPIK

E

10

PENSACOLA FORT WALTON

BEACH

PANAMACITY

CHIPLEY

TALLAHASSEE

75

10

295

95

JACKSONVILLE

ST AUGUSTINE

GAINESVILLE

OCALA DAYTONA BEACH

DELAND4

NEW PORT RICHEY

TAMPA

754

LAKELAND

MELBOURNE -COCOA

ORLANDO

BARTOWST PETERSBURG

275

SARASOTA -

BRADENTON

75

95

FT PIERCE

FT MYERS

WEST PALM

BEACH

FT LAUDERDALE

MIAMI

75

75

NAPLES

KEY WEST

CITY

LAKE

FLO

RID

A'S

BEACH LINE

NO.

SHEET

YEAR

FISCAL

12:26:59 PM H:\_Project18\1812_MatlachaPier\struct\KeySheet01.dgnSabrina 10/11/2019

STRUCTURE PLANS

http://www.dot.state.fl.us/programmanagement/Implemented/SpecBooks

for Road and Bridge Construction at the following website:

Florida Department of Transportation, January 2019 Standard Specifications

http://www.dot.state.fl.us/rddesign/DesignStandards/Standards.shtm

and applicable Design Standards Revisions (DSRs) at the following website:

Florida Department of Transportation, FY 2018-19 Design Standards eBook (DSeB)

LEE COUNTY

CONTRACT PLANS

SHEET NO.

ELAINE CAPPS, P.E.

CONTRACT NO.

CONSTRUCTION

1

LEE COUNTY PROJECT MANAGER:

FACILITIES CONSTRUCTION & MANAGEMENT

MATLACHA FISHING PIER REPLACEMENT

STANDARD PLANS FOR ROAD AND BRIDGE CONSTRUCTION

REGISTRY NO. 27559

FORT MYERS, FL 33901

SUITE 200

2121 MCGREGOR BLVD.

HIGHSPANS ENGINEERING, INC.

P.E. LICENSE NUMBER 60524

VINCENT ZALIAUSKAS, P.E.

LOCATION OF PROJECT

LOCATION OF PROJECT

GOVERNING DESIGN STANDARDS:

GOVERNING STANDARD SPECIFICATIONS:

INDEX OF STRUCTURE PLANS

ENGINEER OF RECORD:

STRUCTURE PLANS

18

515-062

515-061

400-011

PEDESTRIAN/BICYCLE RAILING (ALUMINUM)

BRIDGE PEDESTRIAN/BICYCLE RAILING (ALUMINUM)

GRAVITY WALL

REINFORCING BAR LIST

PIER DETAILS

CLEANING STATION DETAILS

PILE CAP DETAILS

TYPICAL SECTIONS

PLAN & ELEVATION

EXISTING CONDITIONS

GENERAL NOTES

KEY SHEET

15

14

13

11 - 12

8 - 10

5 - 7

4

2 - 3

1

Page 11: REPLY TO ATTENTION OF ATTACHMENT B Documents/Matlacha F… · Fort Myers Permits Section SAJ-1990-40367 (GP-EPL) Ehab Guirguis Lee County Facilities Construction and Management 1500

TH

E

OF

FI

CI

AL

RE

CO

RD

OF

THI

S

SH

EE

T I

S

TH

E

EL

EC

TR

ONI

C

FI

LE

DI

GI

TA

LL

Y

SI

GN

ED

AN

D

SE

AL

ED

UN

DE

R

RU

LE 61

G15-23.004,

F.

A.

C.

SDS 6/19

CLH 6/19

RMW 6/19

VAZ 6/19REGISTRY NO. 27559

FORT MYERS, FL 33901

SUITE 200

2121 MCGREGOR BOULEVARD

HIGHSPANS ENGINEERING, INC.

P.E. LICENSE NUMBER 60524

VINCENT ZALIAUSKAS, P.E. REF. DWG. NO.

SHEET NO.

SHEET TITLE:

PROJECT NAME:

DRAWN BY:

CHECKED BY:

DESIGNED BY:

CHECKED BY:

ROAD NO. COUNTY PROJECT NO.

REVISIONS

DATE BY DESCRIPTION DATE BY DESCRIPTION

LEE

Sabrina 10/11/2019 12:27:00 PM H:\_Project18\1812_MatlachaPier\struct\GeneralNotes01.dgn

CONSTRUCTION & MANAGEMENT

LEE COUNTY FACILITIES

GENERAL NOTES

CONCRETE CLASSCOMPRESSIVE STRENGTH (PSI)

MIN. 28-DAY

IN STRUCTURE

LOCATION OF CONCRETE

5500

3"

2

PRESTRESSED PILING

IS NOTED TO FACE OF CONCRETE.

OF REINFORCING STEEL ARE TO CENTERLINE OF BAR EXCEPT WHERE CLEAR DIMENSION

SECTION 415 FOR ALLOWABLE TOLERANCES. ALL DIMENSIONS PERTAINING TO THE LOCATION

FABRICATION TOLERANCES UNLESS SHOWN AS "MINIMUM COVER". SEE SPECIFICATIONS

CONCRETE COVER DIMENSIONS SHOWN IN THE PLANS DO NOT INCLUDE PLACEMENT AND

PRESTRESSED CONCRETE PILES6000

SUBSTRUCTURE

GENERAL CONSTRUCTION NOTES

CAST-IN-PLACE SUBSTRUCTURE 4"

V (SPECIAL) (W/ SILICA FUME & CALCIUM NITRITE)

IV (W/ SILICA FUME & CALCIUM NITRITE)

CONTRACT DOCUMENTS.

HEREIN, AND JANUARY 2019 STANDARD SPECIFICATIONS FOR ROAD AND BRIDGE CONSTRUCTION, AS AMENDED BY

FLORIDA DEPARTMENT OF TRANSPORTATION, 2019-20 STANDARD PLANS AND REVISED INDEX DRAWINGS AS APPENDED

B. GOVERNING STANDARDS AND CONSTRUCTION SPECIFICATIONS

VERTICAL DATUM USED IS NATIONAL GEODETIC VERTICAL DATUM OF 1929 (NGVD 29), UNLESS OTHERWISE NOTED.

C. VERTICAL DATUM

LOAD AND RESISTANCE FACTOR DESIGN (LRFD) METHOD USING STRENGTH AND SERVICE.

E. DESIGN METHODOLOGY

3. UTILITIES: NO ALLOWANCE FOR UTILITY LOADS HAS BEEN INCLUDED IN THE DESIGN.

PRESSURE TREATED WOOD: 41 PCF

REINFORCED CONCRETE: 150 PCF

2. DEAD LOADS:

WAVE LOAD: 1.088 KIPS APPLIED AT STILL WATER LEVEL

FBC PEDESTRIAN LOAD FOR RAILING: 200 LB + 50 PLF

PEDESTRIAN LIVE LOAD: 100 PSF

1. LIVE LOADS:

F. DESIGN LOADINGS

5. AMERICAN WOOD COUNCIL NATIONAL DESIGN SPECIFICATIONS FOR WOOD CONSTRUCTION, 2012.

4. FDOT DESIGN MANUAL DATED JANUARY, 2019 AND SUBSEQUENT ROADWAY DESIGN BULLETINS.

FACTOR (LRFD) BRIDGE DESIGN SPECIFICATIONS, 8TH EDITION AND ALL SUBSEQUENT INTERIMS.

3. AMERICAN ASSOCIATION OF STATE HIGHWAY AND TRANSPORTATION OFFICIALS (AASHTO) LOAD AND RESISTANCE

2. FDOT STRUCTURES MANUAL DATED JANUARY 2019 AND SUBSEQUENT STRUCTURES DESIGN BULLETINS.

1. FLORIDA BUILDING CODE, CURRENT EDITION

A. DESIGN SPECIFICATIONS

GENERAL NOTES (1 OF 2)

ALL COMPONENTS DESIGNED FOR EXTREMELY AGGRESSIVE ENVIRONMENT.

D. ENVIRONMENT

CLASS 1 OR CLASS 2, BARE CONCRETE WITH BUG HOLES FILLED AND RUBBED.

H. CONCRETE FINISH COATINGCONSTRUCTION WORK HOURS SHALL BE FROM 8:00AM TO 7:00PM SEVEN DAYS A WEEK.16.

ORIGINAL CONDITION AT THE CONTRACTOR’S EXPENSE.ANY PUBLIC OR PRIVATE PROPERTY DAMAGED BY THE CONTRACTOR OR ANY SUB-CONTRACTOR SHALL BE RESTORED TO15.

SUNLIGHT FOR MORE THAN TWO WEEKS. ANCHORING LOCATIONS SHALL BE APPROVED BY THE PROJECT ENGINEER.

ANCHORING BARGES AND OTHER STRUCTURES). THE CONTRACTOR SHALL NOT SHADE ANY BENTHIC COMMUNITY FROM DIRECT

CONTACT WITH THE SEABED IN THESE AREAS AND ANY DISTURBANCE OF BOTTOM SEDIMENT (E.G. FROM MOVING OR

SEAGRASS BEDS AND OTHER BENTHIC COMMUNITIES EXIST IN THE PROJECT AREA. THE CONTRACTOR SHALL PREVENT14.

PROJECT ENGINEER WITHIN 24 HOURS OF EACH ENCOUNTER.

LISTED SPECIES OF SPECIAL CONCERN. SHOULD THESE SPECIES BE ENCOUNTERED, THE CONTRACTOR SHALL CONTACT THE

COMPLY WITH ALL FEDERAL AND STATE REQUIREMENTS REGARDING ENDANGERED AND THREATENED SPECIES AND STATE

AREA: WEST INDIAN MANATEE, SMALLTOOTH SAWFISH, MARINE TURTLES, AND AMERICAN CROCODILE. THE CONTRACTOR SHALL

THE FOLLOWING FEDERALLY AND STATE LISTED ANIMAL SPECIES COULD INHABIT OR MIGRATE THROUGH THE CONSTRUCTION13.

CONSTRUCTION TO AVOID TURBID RUNOFF.

THE CONTRACTOR SHALL MAINTAIN CURRENT WATER QUALITY CONDITIONS AND PROVIDE TURBIDITY BARRIERS DURING12.

CONTROL DEVICES.

ANY MATERIAL TO BE STOCKPILED FOR PERIODS GREATER THAN 24 HOURS SHALL BE PROTECTED BY APPROPRIATE EROSION11.

DEVICES INCLUDING MONITORING, REPORTING AND MAINTENANCE.

THE CONTRACTOR SHALL PROVIDE AN EROSION, SEDIMENTATION, AND POLLUTION PREVENTION PLAN, AND PROVIDE CONTROL10.

DISCHARGE OF ANY FOREIGN MATERIAL INTO THE WATER SHOULD BE PERMITTED.

THIS PROJECT IS LOCATED IN THE MATLACHA PASS AQUATIC PRESERVE. NO DEGRADATION OF WATER QUALITY, AND/OR THE9.

THE CONTRACTOR SHALL ACQUIRE AND MAINTAIN ALL FEDERAL, STATE, AND LOCAL PERMITS REQUIRED FOR CONSTRUCTION.8.

ISSUED OCTOBER 3, 2003: MHW=+1.14 FT, HIGH WATER = +1.43', LOW WATER = 0.0' FT USING NGVD29.

TIDAL ELEVATIONS WERE OBTAINED FROM DEPARTMENT OF ENVIRONMENTAL PROTECTION (DEP) PERMIT NO. 36-0213088-001,7.

PLAN APPROVED BY THE USCG.

RESTRICTING HORIZONTAL AND/OR VERTICAL CLEARANCES THE CONTRACTOR SHALL SUBMIT TO THE COUNTY A CONSTRUCTION

ADDRESS: [email protected], TELEPHONE NUMBER (305) 415-6946. IN ADVANCE OF ANY CONSTRUCTION ACTIVITY

TO NAVIGATION SHALL BE COORDINATED WITH THE UNITED STATES COAST GUARD (USCG), MR. EDDIE LAWRENCE. EMAIL

IN A TIMELY MANNER TO ALLOW BOATS AND OTHER VESSELS TO REASONABLY NAVIGATE THROUGH. ANY SHORT TERM IMPACTS

THE CONTRACTOR IS RESPONSIBLE FOR MAINTAINING NAVIGABLE WATERWAYS. THE CONTRACTOR SHALL MOVE EQUIPMENT6.

PARKING SPACES AND GREEN SPACE FOR STAGING AREA.

STAGING AREAS WITH THE PROJECT ENGINEER AT LEAST SEVENTY-TWO (72) HOURS PRIOR TO USE. CONTRACTOR CAN UTILIZE

ENVIRONMENTALLY SENSITIVE AREAS. THE CONTRACTOR SHALL REVIEW ENVIRONMENTAL REQUIREMENTS OF ANY PROPOSED

NO STAGING OR OTHER ACTIVITIES FOR THIS PROJECT WILL BE ALLOWED WITHIN OR ADJACENT TO THE WATERWAY OR OTHER5.

UTILITIES MUST BE ADJUSTED AT THE CONTRACTORS EXPENSE.

THE CONTRACTOR IS RESPONSIBLE FOR RESOLVING ANY UTILITY CONFLICTS BEFORE CONSTRUCTION BEGINS. ALL CONFLICTING4.

CONSTRUCTION AND NOTIFY THE ENGINEER OF ANY DISCREPANCIES.

IT IS THE CONTRACTOR'S RESPONSIBILITY TO VERIFY INFORMATION AND DATA IN THE PLANS BEFORE BEGINNING3.

REPAIRED AT THE CONTRACTOR'S EXPENSE.

IN THE AREA OF THE PROJECT PRIOR TO BEGINNING CONSTRUCTION ACTIVITIES. DAMAGE TO EXISTING UTILITIES SHALL BE

PRIOR TO BEGINNING CONSTRUCTION ACTIVITIES. THE CONTRACTOR SHALL NOTIFY ALL UTILITY COMPANIES WITH FACILITIES

IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO DETERMINE THE EXACT LOCATION AND OWNERSHIP OF ALL UTILITIES2.

SECTIONS TO ENSURE THAT THE CHANNEL WIDTH/DEPTH HAS NOT BEEN DECREASED.

DIRECTION OF A FLORIDA PROFESSIONAL SURVEYOR AND MAPPER (PSM). THE SURVEY IS TO INCLUDE PROFILE AND CROSS

IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO PERFORM A PRE- AND POST-CONSTRUCTION SURVEY UNDER THE1.

3. CONCRETE COVER:

2. CONCRETE CLASS:

1. REINFORCING STEEL: ALL REINFORCING STEEL SHALL BE ASTM A615 GRADE 60

G. MATERIALS

BULB: AMBER LED LIGHT BULB PART #: PAR38 MADE BY SYNERGY LIGHTING INC., OR APPROVED EQUAL.3.

LUMINAIRE: LIGHT FIXTURE PT40 PART#: 610012 MADE BY LIGHT INC., OR APPROVED EQUAL.2.

POLE: 12'-0" ALUMINUM POLE, PART#: H12A4RS125 MADE BY ENERGY LIGHT INC., OR APPROVED EQUAL.1.

L. LIGHTING

JOINTS OR ALTERATIONS TO THOSE SHOWN SHALL REQUIRE APPROVAL OF THE ENGINEER.

CONSTRUCTION JOINTS WILL BE PERMITTED ONLY AT THE LOCATIONS INDICATED IN THE PLANS. ADDITIONAL CONSTRUCTION

K. JOINTS IN CONCRETE

ALL ELECTRICAL WORK IS TO BE PERFORMED BY A LICENSED ELECTRICIAN.3.

CONTRACTOR IS TO FIELD LOCATE EXISTING UTILITIES.2.

LOCATIONS OF EXISTING UTILITIES SHOWN IN THE PLANS ARE APPROXIMATE.1.

J. UTILITIES

ALL DIMENSIONS IN THESE PLANS ARE MEASURED IN FEET EITHER HORIZONTALLY OR VERTICALLY UNLESS OTHERWISE NOTED.

I. PLAN DIMENSIONS

12. FLORIDA FISH AND WILDLIFE CONSERVATION COMMISSION MONOFILAMENT RECOVERY AND RECYCLE BIN.

APPROVED EQUAL.

11. HIGHLAND PRODUCTS GROUP, LLC 6' LONG, SURFACE MOUNTED TRAILSIDE RECYCLED PLASTIC BENCH, OR

" THICK CUSTOM CLEANING STATION TABLE, OR APPROVED EQUAL.43BOAT OUTFITTERS 4'-0"x2'-6"x10.

GIBSON STAINLESS & SPECIALTY INC. 2" STAINLESS STEEL CONDUIT TWO HOLE STRAP, OR APPROVED EQUAL.9.

GIBSON STAINLESS & SPECIALTY INC. 2" STAINLESS STEEL CONDUIT HANGERS, OR APPROVED EQUAL.8.

ALL HARDWARE IS STAINLESS STEEL 316, UNLESS NOTED OTHERWISE.a.

STEEL FASTENERS AND HARDWARE7.

THE WIDTH OF THE PIER TO ENSURE DECKING HAS A FIRM CONTACT WITH ALL STRINGERS.

" TO PROVIDE A FLAT SURFACE ACROSS83VARIATION IN DEPTH BETWEEN STRINGERS SHALL NOT EXCEED c.

BORING WITH PRESERVATIVE TREATMENT USED FOR PILES OR TIMBER.

DEPRESSIONS OR OPENINGS AROUND BOLT HOLES, JOINTS, OR GAPS INCLUDING RECESSES FORMED BY COUNTER

TIMBERS IN ACCORDANCE WITH AWPA; TRIM CUTS AND ABRASIONS BEFORE FIELD TREATMENT; PAINT

FIELD TREAT CUTS, BEVELS, NOTCHES, REFACING AND ABRASIONS MADE IN THE FIELD IN TREATED PILES ORb.

PRESSURE TREATED SOUTHERN YELLOW PINE #2 S4S 0.40 ACQa.

WOOD STRINGERS AND BLOCKING6.

" MAX. GAP BETWEEN DECK BOARDS.21PROVIDE b.

TANDECK ULTIMATE MARINE DOCK BOARD, OR APPROVED EQUAL.a.

WOOD DECKING AND HANDRAILS5.

LOAD STABILITY.

PILES DRIVEN TO CUTOFF ELEVATION WILL MEET THE MINIUMUM 2:1 EMBEDMENT REQUIRED FOR LATERALc.

T-HEAD PILE LENGTHS: 25 FTb.

MAIN PIER PILE LENGTHS: 20 FTa.

CONCRETE PILES4.

MATLACHA FISHING PIER REPLACEMENT

Page 12: REPLY TO ATTENTION OF ATTACHMENT B Documents/Matlacha F… · Fort Myers Permits Section SAJ-1990-40367 (GP-EPL) Ehab Guirguis Lee County Facilities Construction and Management 1500

TH

E

OF

FI

CI

AL

RE

CO

RD

OF

THI

S

SH

EE

T I

S

TH

E

EL

EC

TR

ONI

C

FI

LE

DI

GI

TA

LL

Y

SI

GN

ED

AN

D

SE

AL

ED

UN

DE

R

RU

LE 61

G15-23.004,

F.

A.

C.

SDS 6/19

CLH 6/19

RMW 6/19

VAZ 6/19REGISTRY NO. 27559

FORT MYERS, FL 33901

SUITE 200

2121 MCGREGOR BOULEVARD

HIGHSPANS ENGINEERING, INC.

P.E. LICENSE NUMBER 60524

VINCENT ZALIAUSKAS, P.E. REF. DWG. NO.

SHEET NO.

SHEET TITLE:

PROJECT NAME:

DRAWN BY:

CHECKED BY:

DESIGNED BY:

CHECKED BY:

ROAD NO. COUNTY PROJECT NO.

REVISIONS

DATE BY DESCRIPTION DATE BY DESCRIPTION

LEE

Sabrina 10/11/2019 12:27:01 PM H:\_Project18\1812_MatlachaPier\struct\GeneralNotes01.dgn

CONSTRUCTION & MANAGEMENT

LEE COUNTY FACILITIES

NOISE BEST MANAGEMENT PRACTICES (BMPS) FOR PILING INSTALLATION

BALLAST TO COUNTERACT THE BUOYANCY OF THE AERATION PIPES IN OPERATION.

FACILITATES TRANSPORT AND PLACEMENT OF THE SYSTEM, KEEPS THE AERATION PIPES STABLE, AND PROVIDES

THE AIR, DISTRIBUTION MANIFOLDS OR HEADERS, PERFORATED AERATION PIPE, AND A FRAME. THE FRAME

GENERAL - AN UNCONFINED BUBBLE CURTAIN IS COMPOSED OF AN AIR COMPRESSOR(S), SUPPLY LINES TO DELIVERA.

DISTRIBUTE SMALL AIR BUBBLES AROUND 100% OF THE PILE PERIMETER FOR THE FULL DEPTH OF THE WATER COLUMN.

INSTALLATION PERIOD, SURROUND THE PILE BEING DRIVEN BY A CONFINED OR UNCONFINED BUBBLE CURTAIN THAT WILL

IF WATER VELOCITY IS EQUAL TO OR LESS THAN 1.6 ft PER SECOND (1.1 MILES PER HOUR) FOR THE ENTIRE1.

METHODS:

WHEN USING AN IMPACT HAMMER TO DRIVE OR PROOF CONCRETE PILES, USE ONE OF THE FOLLOWING SOUND ATTENUATION

BUBBLE CURTAIN SPECIFICATIONS FOR PILE DRIVING

INSTALLED BY VIBRATORY HAMMER INSTEAD, FOLLOWING BMP PLAN A).

A DIFFERENT METHOD USING THE APPROPRIATE NOISE BMPS DEFINED IN THIS DOCUMENT. (E.G., CONCRETE PILES MAY BE

IF THE REQUIRED NOISE ABATEMENT MEASURE DISCUSSED ABOVE CANNOT BE USED, THEN THE PILE MUST BE INSTALLED BY

CONTROL METHOD MUST RECEIVE PRIOR APPROVAL BY NMFS AND THE USACE.

BELOW, AND BE FOLLOWED AS DETAILED IN THE USACE PERMIT APPLICATION. THE USE OF ANY OTHER ALTERNATIVE NOISE

BUBBLE CURTAIN DESIGN MUST ADHERE TO THE GUIDELINES FOR UNCONFINED AND CONFINED BUBBLE CURTAINS DEFINED

BEING DRIVEN, AND EXTEND AT LEAST 3 ft ABOVE THE SURFACE OF THE WATER.

BETWEEN THE WALLS. THE TNAP MUST BE LONG ENOUGH TO BE SEATED FIRMLY ON THE SEA BOTTOM, FIT OVER THE PILE

LEAST A 5-in WIDE HOLLOW SPACE COMPLETELY FILLED WITH CLOSED-CELL FOAM OR OTHER NOISE DAMPENING MATERIAL

TNAP DESIGN MUST BE CONSTRUCTED OF A DOUBLE-WALLED TUBULAR CASING (A CASING WITHIN A LARGER CASING), WITH AT

BUBBLE CURTAINS.

NOISE ABATEMENT MEASURES: APPROVED NOISE ABATEMENT MEASURES INCLUDE NOISE ATTENUATION PILES (TNAP) AND/OR

REQUIRED FOR ALL OF THE CONCRETE PILES INSTALLED THAT DAY WITH A MAXIMUM OF 10 PILES INSTALLED PER DAY.

IF MORE THAN 5 PILES WILL BE INSTALLED PER DAY IN A CONFINED SPACE, NOISE ABATEMENT MEASURES (BELOW) ARE4.

BE INSTALLED PER DAY.

IF THE PROJECT IS LOCATED IN A CONFINED SPACE, UP TO 5 CONCRETE PILES MEASURING UP TO 24-in DIAMETER MAY3.

INSTALLED PER DAY.

IF THE PROJECT IS LOCATED IN OPEN WATER, UP TO 10 CONCRETE PILES MEASURING UP TO 24-in DIAMETER MAY BE2.

OR SIGNIFICANTLY REFLECT NOISE.

INCLUDE OBJECTS SUCH AS DOCKS OR OTHER PILE-SUPPORTED STRUCTURES THAT WOULD NOT STOP ANIMAL MOVEMENT

SERVE AS A BARRIER OR OTHERWISE PREVENT ANIMALS FROM MOVING PAST IT TO EXIT THE AREA. THIS DOES NOT

SEAWALL, JETTY) OR STRUCTURE WITHIN 150 FEET (ft) OF THE PILE INSTALLATION SITE THAT WOULD EFFECTIVELY

SOURCE TO ESCAPE IT. A CONFINED SPACE IS DEFINED AS ANY AREA THAT HAS A SOLID OBJECT (E.G., SHORELINE,

IMPORTANT BECAUSE IF A PROJECT OCCURS IN A CONFINED SPACE, AN ANIMAL MAY NOT MOVE THROUGH OR PAST A NOISE

IT MUST BE DETERMINED IF THE PROJECT OCCURS IN OPEN WATER OR A CONFINED SPACE. THIS DIFFERENTIATION IS1.

BELOW:

THE PERMITTEE SHALL FOLLOW ALL CONDITIONS DEFINED IN THE NOISE BMP PLAN A ABOVE PLUS THE CONDITIONS PROVIDED

NOISE BMP PLAN B (FOR IMPACT PILE-DRIVING INSTALLATION OF 6 OR MORE CONCRETE PILES PER DAY)

ALL WORK MUST OCCUR DURING DAYLIGHT HOURS.F.

STRANDING/RESCUE ORGANIZATION.

SERVICE’S PROTECTED RESOURCES DIVISION (727-824-5312) AND THE LOCAL AUTHORIZED SEA TURTLEANY INJURY TO A PROTECTED SPECIES SHALL BE REPORTED IMMEDIATELY TO THE NATIONAL MARINE FISHERIESE.

PROTECTED SPECIES HAS DEPARTED THE PROJECT AREA OF ITS OWN VOLITION.

PROTECTED SPECIES IS SEEN WITHIN A 50-ft RADIUS OF THE EQUIPMENT. ACTIVITIES MAY NOT RESUME UNTIL THE

PROTECTED SPECIES. OPERATION OF ANY MECHANICAL CONSTRUCTION EQUIPMENT SHALL CEASE IMMEDIATELY IF A

PRECAUTIONS SHALL INCLUDE CESSATION OF OPERATION OF ANY MOVING EQUIPMENT CLOSER THAN 50 ft OF A

VESSEL MOVEMENT, ALL APPROPRIATE PRECAUTIONS SHALL BE IMPLEMENTED TO ENSURE ITS PROTECTION. THESE

IF A PROTECTED SPECIES IS SEEN WITHIN 100 yd OF THE ACTIVE DAILY CONSTRUCTION/DREDGING OPERATION ORD.

THE NATIONAL MARINE FISHERIES SERVICE’S PROTECTED RESOURCES DIVISION, ST. PETERSBURG, FLORIDA.BLOCK PROTECTED SPECIES ENTRY TO OR EXIT FROM DESIGNATED CRITICAL HABITAT WITHOUT PRIOR AGREEMENT FROM

PROPERLY SECURED, AND BE REGULARLY MONITORED TO AVOID PROTECTED SPECIES’ ENTRAPMENT. BARRIERS MAY NOTSILTATION BARRIERS SHALL BE MADE OF MATERIAL IN WHICH PROTECTED SPECIES CANNOT BECOME ENTANGLED, BEC.

HARMING, HARASSING, OR KILLING SPECIES PROTECTED UNDER THE ENDANGERED SPECIES ACT OF 1973.

THE PERMITTEE SHALL ADVISE ALL CONSTRUCTION PERSONNEL THAT THERE ARE CIVIL AND CRIMINAL PENALTIES FORB.

PRESENCE OF THESE SPECIES.

ALL CONSTRUCTION PERSONNEL ARE RESPONSIBLE FOR OBSERVING WATER-RELATED ACTIVITIES TO DETECT THEA.

THE PERMITTEE SHALL COMPLY WITH THE FOLLOWING PROTECTED SPECIES CONSTRUCTION CONDITIONS:

NOISE BMP PLAN A (FOR ALL PROJECTS): SEA TURTLE, SMALLTOOTH SAWFISH, AND STURGEON CONSTRUCTION CONDITIONS.

DOCK AND SEAWALL CONSTRUCTION ACTIVITIES.

SAWFISH, AND STURGEON TO POTENTIAL HARMFUL DAILY NOISE EXPOSURE LEVELS ASSOCIATED WITH PILE DRIVING DURING

THE FOLLOWING BEST MANAGEMENT PRACTICES ARE DESIGNED TO REDUCE THE EXPOSURE TO SEA TURTLES, SMALLTOOTH

2

NO. OF LAYERSWATER DEPTH (m)

0 TO LESS THAN 5

4

7

10

13

5 TO LESS THAN 10

10 TO LESS THAN 15

15 TO LESS THAN 20

20 TO LESS THAN 25

EITHER LAMINAR FLOW OR NON-LAMINAR FLOW.

FLOW METERS SHALL BE INSTALLED ACCORDING TO THE MANUFACTURER’S RECOMMENDATION BASED ONIII.

CAN BE ELIMINATED.

CONTINUOUS FROM THE COMPRESSOR TO THE AERATION PIPE INLET, THE FLOW METER AT THE COMPRESSOR

AERATION PIPELINES AT EACH INLET. IN APPLICATIONS WHERE THE FEED LINE FROM THE COMPRESSOR IS

FLOW METERS SHALL BE INSTALLED IN THE MAIN LINE AT EACH COMPRESSOR AND AT EACH BRANCH OF THEII.

PRESSURE IN EACH BRANCH OF THE AERATION PIPELINE.

PRESSURE METERS SHALL BE INSTALLED AT ALL INLETS TO AERATION PIPELINES AND AT POINTS OF LOWEST

FLOW METERS SHALL BE PROVIDED AS FOLLOWS:H.

Vt = 21.53 ft�/min/ft * CIRCUMFERENCE OF THE AERATION RING IN ftOR

Vt = 2.0 m�/min/m * CIRCUMFERENCE OF THE AERATION RING IN mOF THE BUBBLE FLUX AND THE CIRCUMFERENCE OF THE RING:

(21.53 ft³ PER MINUTE PER LIN FT OF PIPE IN EACH LAYER). THE TOTAL VOLUME OF AIR PER LAYER IS THE PRODUCT

THE SYSTEM SHALL PROVIDE A BUBBLE FLUX OF 2.0 m³ PER MINUTE PER LINEAR METER OF PIPE IN EACH LAYERG.

UNIFORM BUBBLE FLUX.

AIR HOLES WITH THIS SIZE AND SPACING SHALL BE PLACED IN 4 ADJACENT ROWS ALONG THE PIPE TO PROVIDE

AIR HOLES SHALL BE 1.6 mm (1/16-in) IN DIAMETER AND SHALL BE SPACED APPROXIMATELY 20 mm (3/4 in) APART.F.

SUBSTRATE WITHOUT SINKING INTO THE SUBSTRATE AND SHALL ACCOMMODATE FOR SLOPED CONDITIONS.

THE LOWEST LAYER OF PERFORATED AERATION PIPE SHALL BE DESIGNED TO ENSURE CONTACT WITH THEE.

AND THE OTHER AT MID-DEPTH.

IN-WATERS GREATER THAN 15 m DEEP, THE SYSTEM SHALL HAVE AT LEAST 2 RINGS: 1 AT THE SUBSTRATE LEVEL

IN-WATER LESS THAN 15 m DEEP, THE SYSTEM SHALL HAVE A SINGLE AERATION RING AT THE SUBSTRATE LEVEL.D.

INTO THE WATER COLUMN (E.G., RUBBER SPACERS, AIR-FILLED CUSHIONS).

COMING INTO CONTACT WITH EACH OTHER AND DO NOT TRANSMIT VIBRATIONS TO THE CONFINEMENT SLEEVE AND

THE CONFINEMENT SHALL CONTAIN RESILIENT PILE GUIDES THAT PREVENT THE PILE AND THE CONFINEMENT FROMC.

TOP OF THE CONFINEMENT SYSTEM).

THE BUBBLE CURTAIN DOES NOT ACT AS A WATER PUMP (I.E., LITTLE OR NO WATER SHOULD BE PUMPED OUT OF THE

LEVEL EXPECTED DURING PILE INSTALLATION SUCH THAT WHEN THE AIR DELIVERY SYSTEM IS ADJUSTED PROPERLY,

THE CONFINEMENT SHALL EXTEND FROM THE SUBSTRATE TO A SUFFICIENT ELEVATION ABOVE THE MAXIMUM WATERB.

BUBBLES.

AIR, DISTRIBUTION MANIFOLDS OR HEADERS, PERFORATED AERATION PIPE(S), AND A MEANS OF CONFINING THE

GENERAL - A CONFINED BUBBLE CURTAIN IS COMPOSED OF AN AIR COMPRESSOR(S), SUPPLY LINES TO DELIVER THEA.

SPECIFICATIONS BELOW.

AIR BUBBLES AROUND 100% OF THE PILE PERIMETER FOR THE FULL DEPTH OF THE WATER COLUMN, ACCORDING TO

BUBBLE RING SURROUNDED BY A FABRIC OR NON-METALLIC SLEEVE). THE CONFINED BUBBLE CURTAIN WILL DISTRIBUTE

OR IF CONSTRUCTING A SEAWALL, SURROUND THE PILE OR AREA BEING DRIVEN BY A CONFINED BUBBLE CURTAIN (E.G., A

IF WATER VELOCITY IS GREATER THAN 1.6 ft PER SECOND (1.1 MILES PER HOUR) AT ANY POINT DURING INSTALLATION2.

EITHER LAMINAR FLOW OR NON-LAMINAR FLOW.

FLOW METERS SHALL BE INSTALLED ACCORDING TO THE MANUFACTURER’S RECOMMENDATION BASED ON•AT THE COMPRESSOR CAN BE ELIMINATED.

COMPRESSOR IS CONTINUOUS FROM THE COMPRESSOR TO THE AERATION PIPE INLET, THE FLOW METER

THE AERATION PIPELINES AT EACH INLET. IN APPLICATIONS WHERE THE FEED LINE FROM THE

FLOW METERS SHALL BE INSTALLED IN THE MAIN LINE AT EACH COMPRESSOR AND AT EACH BRANCH OF•LOWEST PRESSURE IN EACH BRANCH OF THE AERATION PIPELINE.

PRESSURE METERS SHALL BE INSTALLED AT ALL INLETS TO AERATION PIPELINES AND AT POINTS OF•METERS SHALL BE PROVIDED AS FOLLOWS:IV.

Vt = 32.91 ft³/min/ft * CIRCUMFERENCE OF THE AERATION RING IN ft

OR

Vt = 3.0 m³/min/m * CIRCUMFERENCE OF THE AERATION RING IN m

PRODUCT OF THE BUBBLE FLUX AND THE CIRCUMFERENCE OF THE RING:

(32.91 ft³ PER MINUTE PER LIN FT OF PIPE IN EACH LAYER). THE TOTAL VOLUME OF AIR PER LAYER IS THE

THE SYSTEM SHALL PROVIDE A BUBBLE FLUX 3.0 m³ PER MINUTE PER LINEAR METER OF PIPE IN EACH LAYERIII.

ALONG THE PIPE TO PROVIDE UNIFORM BUBBLE FLUX.

20 mm (3/4 in) APART. AIR HOLES WITH THIS SIZE AND SPACING SHALL BE PLACED IN 4 ADJACENT ROWS

AIR HOLES SHALL BE 1.6 MILLIMETER (mm) (1/16-in) IN DIAMETER AND SHALL BE SPACED APPROXIMATELYII.

SUBSTRATE WITHOUT BURIAL AND SHALL ACCOMMODATE SLOPED CONDITIONS.

THE LOWEST LAYER OF PERFORATED AERATION PIPE SHALL BE DESIGNED TO ENSURE CONTACT WITH THEI.

A RADIAL DIMENSION SUCH THAT THE RINGS ARE NO MORE THAN 0.5 m FROM THE OUTSIDE SURFACE OF THE PILE.

BEING DRIVEN TO BE COMPLETELY ENCLOSED BY BUBBLES FOR THE FULL DEPTH OF THE WATER COLUMN AND WITH

THE PIPES IN ALL LAYERS SHALL BE ARRANGED IN A GEOMETRIC PATTERN WHICH SHALL ALLOW FOR THE PILEC.

VERTICALLY IN ACCORDANCE WITH THE FOLLOWING:

THE AERATION PIPE SYSTEM SHALL CONSIST OF MULTIPLE LAYERS OF PERFORATED PIPE RINGS, STACKEDB.

3

GENERAL NOTES (2 OF 2)

MATLACHA FISHING PIER REPLACEMENT

Page 13: REPLY TO ATTENTION OF ATTACHMENT B Documents/Matlacha F… · Fort Myers Permits Section SAJ-1990-40367 (GP-EPL) Ehab Guirguis Lee County Facilities Construction and Management 1500

5.67

5.64

4.04

7

-0.13

-0.14

3.43

2

-0.95

5.11

2

-0.99

-1.86

-0.99

-0.55

-0.42

-0.94

-1.52

-2.30

-3.20

-1.51

-1.55

-1.51

-1.60

-1.70

-1.53

-2.13

-2.42

-3.03

-0.53

-0.77

-0.74

-0.66

-0.79

-1.26

-0.95

-1.05

-1.16

-1.02

-0.90

-0.63

-0.97

-0.32

-0.69

-0.47

-0.28

-0.35

-0.52

-0.24

-0.43

-1.09

-1.18

-1.42

-1.04

-1.39

-1.54

-1.36

-1.16

-0.72

-0.91

-0.85

-0.65

-0.54

-0.46

-0.28

-0.12

0.06

0.33

0.68

1.69

2.49

2.69 2.

39 1.58 0.

49 0.39

2.91

3.08

2.98

2.96

4.99

4.84

5.05

4.76

5.06

5.09

5.06

5.25

5.27

5.44

5.12

5.115.12

5.25

4.985.24

5.28

5.28

5.34

5.11

5.30

5.40

4.81

4.12

4.88

4.79

4.81

4.64

4.704.

59

3.04

4.53

4.86

4.07

2.63

3.182.

92

2.75

4.37

4.96

4.50

4.48

3.532.

52

3.62

2.75

2.87

3.76

4.36

4.90

5.34

5.45

5.49

5.48

5.56

5.36

5.34

5.37

5.16

5.42

4.99

5.19

5.22

5.31

5.25

5.28

5.23

5.24

5.08

5.18

2.87

4.14

2.74

4.09

2.88

3.76

4.14

4.09

4.30

4.09

3.43

4.63

2.60

4.03

4.56

4.60

3.91

4.69

4.66

4.52

4.71

3.02

4.24

3.14

3.31 3.

122.71

3.89

4.89

4.02

0.53

2.50

2.89

2.85

3.57 2.

80

2.71

0.18

PIE

R

OFF

NE

TTIN

G

CAS

T

NO

PIE

R

OFF

NE

TTIN

G

CAS

T

NO

XX.XX

5.89

X.XX

6.05

5.60

5.96 5.

84

5.81

5.80

5.75

5.80

5.76

6.00

5.81P

IER

OFF

NE

TTIN

G

CAS

T

NO

TOTAL AREA = 44.0 SF

APPROXIMATE NO. PILES = 80

AREA 10" DIA. PILES = 0.55 SF

EXISTING TIMBER PILES:2.

APPROXIMATE EXISTING TIMBER DECK AREA = 3020 SF1.

WOOD

TH

E

OF

FI

CI

AL

RE

CO

RD

OF

THI

S

SH

EE

T I

S

TH

E

EL

EC

TR

ONI

C

FI

LE

DI

GI

TA

LL

Y

SI

GN

ED

AN

D

SE

AL

ED

UN

DE

R

RU

LE 61

G15-23.004,

F.

A.

C.

SDS 6/19

CLH 6/19

RMW 6/19

VAZ 6/19REGISTRY NO. 27559

FORT MYERS, FL 33901

SUITE 200

2121 MCGREGOR BOULEVARD

HIGHSPANS ENGINEERING, INC.

P.E. LICENSE NUMBER 60524

VINCENT ZALIAUSKAS, P.E.

EXISTING CONDITIONS

EXISTING CONCRETE PATH

EXISTING SAND PATH

TREE & ROCK LINE

TREE LINE

±10'-

0"

±70'-

6"

±230'-0"

±16'-0"±184'-0"±30'-0" RAMP

±22'-

0"

±38'-

6"

LEGEND

EXISTING ASPHALT PATH

EXISTING GROUND ELEVATION

EXISTING DECK ELEVATION

TO REMAIN

EXISTING SIGN

TO REMAIN

TRASH CAN

EXISTING

RAMP

±16'-0"

TO BE REPLACED

EXISTING BENCH

TO BE REPLACED

EXISTING BENCH

TO BE REPLACED

EXISTING CLEANING STATION

TO BE REPLACED

EXISTING SIGN

TO BE REPLACED

EXISTING SIGN

EXISTING DRIVEWAY

AND PILINGS TO BE REMOVED

EXISTING TIMBER PIER

4

TO BE REPLACED

EXISTING LIGHT POLE

TO BE REPLACED

EXISTING LIGHT POLE

TO BE REPLACED

EXISTING LIGHT POLE

TO BE REPLACED

EXISTING LIGHT POLE

TO BE REPLACED

EXISTING TRASH CAN

AND TIMBER PILE CAP (TYP.)

EXISTING 10" DIA. TIMBER PILES

NOTES

REF. DWG. NO.

SHEET NO.

SHEET TITLE:

PROJECT NAME:

DRAWN BY:

CHECKED BY:

DESIGNED BY:

CHECKED BY:

ROAD NO. COUNTY PROJECT NO.

REVISIONS

DATE BY DESCRIPTION DATE BY DESCRIPTION

LEE

Sabrina 10/11/2019 12:27:02 PM H:\_Project18\1812_MatlachaPier\struct\ExistingConditions.DGN

CONSTRUCTION & MANAGEMENT

LEE COUNTY FACILITIES

MATLACHA FISHING PIER REPLACEMENT

Page 14: REPLY TO ATTENTION OF ATTACHMENT B Documents/Matlacha F… · Fort Myers Permits Section SAJ-1990-40367 (GP-EPL) Ehab Guirguis Lee County Facilities Construction and Management 1500

MA

TC

HLIN

EM

AT

CH

LIN

E

SIDEWALK

LEVEL PAD

8'-6"

WATER

TH

E

OF

FI

CI

AL

RE

CO

RD

OF

THI

S

SH

EE

T I

S

TH

E

EL

EC

TR

ONI

C

FI

LE

DI

GI

TA

LL

Y

SI

GN

ED

AN

D

SE

AL

ED

UN

DE

R

RU

LE 61

G15-23.004,

F.

A.

C.

SDS 6/19

CLH 6/19

RMW 6/19

VAZ 6/19REGISTRY NO. 27559

FORT MYERS, FL 33901

SUITE 200

2121 MCGREGOR BOULEVARD

HIGHSPANS ENGINEERING, INC.

P.E. LICENSE NUMBER 60524

VINCENT ZALIAUSKAS, P.E.

MAIN PIER PLAN VIEW

2"x10" PT STRINGER

2"x6" DECK

0

-5

5

10

15

-10

10'-

0"

MAIN PIER ELEVATION VIEW

0

-5

5

10

15

-10

PLAN AND ELEVATION (1 OF 3)

EL. = 7.1'

FINISHED DECK

GROUND

EXISTING

8'-0" PILE

SPACING (TYP.)

SPACING (TYP.)

8'-0" PILE14" CONCRETE PILE (TYP.)

EL. = ±5.8'

EXISTING DECK

CONCRETE SIDEWALK

MATCH EXISTING

EL. = ±4.5'

EXISTING

EL. = ±4.7'

EXISTING

EL. = ±4.7'

EXISTING

4'-

0"

4'-

0"

CONNECT TO EXISTING WATERLINE

27'-6" RAMP @ 1:12 SLOPE MAX. 183'-6" MAIN PIER

WATERLINE

2" PVC, SCHEDULE 80INSTALL WATER VALVE

EXISTING CONCRETE PATH

EXISTING SAND PATH

LEGEND

EXISTING ASPHALT PATH

183'-6" MAIN PIER27'-6" RAMP @ 1:12 SLOPE MAX.

PROPOSED CONCRETE PATH

EL. = ±5.1'

EXISTING

SIDEWALK

CONCRETE

EL. = 4.8'

END RAMP

8'-6" CONC.

6'-0" MIN. 5'-2" O.C. RAMP

(INDEX 400-011)

GRAVITY WALL

(INDEX 400-011)

PROPOSED GRAVITY WALL

5'-0"

MIN.

ELECTRIC

2" PVC, SCHEDULE 80

CONNECT TO EXISTING ELECTRIC

6'-0" MAIN PIER

SPACING (TYP.)

RAILING POSTS

SPACING (TYP.)

RAILING POST

6'-0" MAIN PIER

SPACING (TYP.)

RAILING POSTS

5'-2"

5'-2" O.C. RAMP

SPACING (TYP.)

RAILING POST

RAILING, TYPE 2 (INDEX 515-062)

ALUMINUM PEDESTRIAN/BICYCLE

CONCRETE PILE CAP (TYP.)

PROPOSED LIGHT POLE

2'-0"

1'-6"

3'-2"

SUBMIT SHOP DRAWING FOR APPROVAL

PROPOSED BOLLARD (TYP.)

5

PROPOSED LIGHT POLE

MHW= 1.14

14"x14" CONCRETE PILE (TYP.)

REF. DWG. NO.

SHEET NO.

SHEET TITLE:

PROJECT NAME:

DRAWN BY:

CHECKED BY:

DESIGNED BY:

CHECKED BY:

ROAD NO. COUNTY PROJECT NO.

REVISIONS

DATE BY DESCRIPTION DATE BY DESCRIPTION

LEE

Sabrina 10/11/2019 12:27:03 PM H:\_Project18\1812_MatlachaPier\struct\B1PlanElev01.DGN

CONSTRUCTION & MANAGEMENT

LEE COUNTY FACILITIES

MATLACHA FISHING PIER REPLACEMENT

Page 15: REPLY TO ATTENTION OF ATTACHMENT B Documents/Matlacha F… · Fort Myers Permits Section SAJ-1990-40367 (GP-EPL) Ehab Guirguis Lee County Facilities Construction and Management 1500

TH

E

OF

FI

CI

AL

RE

CO

RD

OF

THI

S

SH

EE

T I

S

TH

E

EL

EC

TR

ONI

C

FI

LE

DI

GI

TA

LL

Y

SI

GN

ED

AN

D

SE

AL

ED

UN

DE

R

RU

LE 61

G15-23.004,

F.

A.

C.

SDS 6/19

CLH 6/19

RMW 6/19

VAZ 6/19REGISTRY NO. 27559

FORT MYERS, FL 33901

SUITE 200

2121 MCGREGOR BOULEVARD

HIGHSPANS ENGINEERING, INC.

P.E. LICENSE NUMBER 60524

VINCENT ZALIAUSKAS, P.E.

PIE

R

OFF

NE

TTIN

G

CAS

T

NO

PIE

R

OFF

NE

TTIN

G

CAS

T

NO

REF. DWG. NO.

SHEET NO.

SHEET TITLE:

PROJECT NAME:

DRAWN BY:

CHECKED BY:

DESIGNED BY:

CHECKED BY:

ROAD NO. COUNTY PROJECT NO.

REVISIONS

DATE BY DESCRIPTION DATE BY DESCRIPTION

LEE

Sabrina 10/11/2019 12:27:04 PM H:\_Project18\1812_MatlachaPier\struct\B1PlanElev02.DGN

CONSTRUCTION & MANAGEMENT

LEE COUNTY FACILITIES

MAIN PIER PLAN VIEW

2"x10" PT STRINGER

2"x6" DECK

0

-5

5

10

15

-10

10'-

0"

MAIN PIER ELEVATION VIEW

0

-5

5

10

15

-10

PLAN AND ELEVATION (2 OF 3)

T-HEAD PIER

EXISTING GROUND

EL. = 7.1'

FINISHED DECK

14" CONCRETE PILE (TYP.)

8'-0" PILE

SPACING (TYP.)

SPACING (TYP.)

8'-0" PILE

MA

TC

HLIN

EM

AT

CH

LIN

E

EL. = ±5.8'

EXISTING DECK

BIN

RECYCLE

CAN &

TRASH

ATTACH TO RAILING

18"x24"

183'-6" MAIN PIER 16'-0"

CONCRETE PILE CAP (TYP.)

WATERLINE

2" PVC, SCHEDULE 80

ELECTRIC

2" PVC, SCHEDULE 80

PROPOSED LIGHT POLE

6'-0" MAIN PIER

SPACING (TYP.)

RAILING POSTS

RAILING, TYPE 2 (INDEX 515-062)

ALUMINUM PEDESTRIAN/BICYCLE

SPACING (TYP.)

RAILING POSTS

6'-0" MAIN PIER

BENCH

6

CLEANING STATION

ADA COMPLIANT FISH

FISH CLEANING STATION

183'-6" MAIN PIER

T-HEAD PIER

16'-0"

PROPOSED LIGHT POLE

MO

ORIN

G

NO

OUTSIDE RAILING

ATTACH TO THE

18"x24"

INSIDE RAILING

ATTACH TO THE

18"x24"

MHW= 1.14

14"x14" CONCRETE PILE (TYP.)

MATLACHA FISHING PIER REPLACEMENT

Page 16: REPLY TO ATTENTION OF ATTACHMENT B Documents/Matlacha F… · Fort Myers Permits Section SAJ-1990-40367 (GP-EPL) Ehab Guirguis Lee County Facilities Construction and Management 1500

TH

E

OF

FI

CI

AL

RE

CO

RD

OF

THI

S

SH

EE

T I

S

TH

E

EL

EC

TR

ONI

C

FI

LE

DI

GI

TA

LL

Y

SI

GN

ED

AN

D

SE

AL

ED

UN

DE

R

RU

LE 61

G15-23.004,

F.

A.

C.

SDS 6/19

CLH 6/19

RMW 6/19

VAZ 6/19REGISTRY NO. 27559

FORT MYERS, FL 33901

SUITE 200

2121 MCGREGOR BOULEVARD

HIGHSPANS ENGINEERING, INC.

P.E. LICENSE NUMBER 60524

VINCENT ZALIAUSKAS, P.E.

PIER

OFF

NETTING

CAST

NO

REF. DWG. NO.

SHEET NO.

SHEET TITLE:

PROJECT NAME:

DRAWN BY:

CHECKED BY:

DESIGNED BY:

CHECKED BY:

ROAD NO. COUNTY PROJECT NO.

REVISIONS

DATE BY DESCRIPTION DATE BY DESCRIPTION

LEE

Sabrina 10/11/2019 12:27:06 PM H:\_Project18\1812_MatlachaPier\struct\B1PlanElev03.DGN

CONSTRUCTION & MANAGEMENT

LEE COUNTY FACILITIES

T-HEAD PIER PLAN VIEW

T-HEAD PIER ELEVATION VIEW

16'-

0"

73'-2" T-HEAD PIER

73'-2" T-HEAD PIER

39'-7"10'-0" MAIN PIER23'-7"

1'-

2"

GROUND

EXISTING

PLAN AND ELEVATION (3 OF 3)

-10

-5

0

5

10

15

-10

-5

0

5

10

15

STRINGER

2"x10" PT

EL. = 7.1'

FINISHED DECK

SPACING (TYP.)

8'-0" PILE

8'-0" PILE

SPACING (TYP.)

7'-0"

7'-0"

EL. = ±5.8'

EXISTING DECK

2'-

6"

9"

BIN

RECYCLE

CAN &

TRASH

CAP (TYP.)

CONCRETE PILE

WATERLINE

2" PVC, SCHEDULE 80

BENCHBENCH

"215'-4"2

15'-4"215'-4"2

15'-4 6'-3"6'-3"6'-3"6'-3"6'-3"6'-3"

7'-

0"

7'-

0"

5'-11"5'-11"5'-11"5'-11"5'-11"5'-11"5'-11"5'-11"5'-11"5'-11"5'-11"5'-11"

(TYP.)

PILE

CONRETE

14"x14"

1'-1" 1'-1"

1'-

0"

1'-

0"

1'-0" 1'-0"

7'-

0"

7'-

0"

1'-

0"

1'-1"

SP

ACIN

G

RAILIN

G P

OS

T

SPACING

RAILING POST

LIGHT POLE

PROPOSED

1'-

0"

SP

ACIN

G

RAILIN

G P

OS

T

1'-1"

SPACING

RAILING POST

LIGHT POLE

PROPOSED

RAILING, TYPE 2 (INDEX 515-062)

ALUMINUM PEDESTRIAN/BICYCLE5'-2"

3'-

6"

SPACING

RAILING POST

5'-2"

RAILING

ATTACH TO

18"x24"

7

(TYP.)

CONCRETE PILE

14"x14"

FISH CLEANING STATION

CLEANING STATION

ADA COMPLIANT FISH

LIGHT POLE

PROPOSEDLIGHT POLE

PROPOSED

MO

ORIN

GNO

OUTSIDE RAILING

ATTACH TO THE

18"x24"

MO

ORIN

G

NO

OUTSIDE RAILING

ATTACH TO THE

18"x24"

ELECTRIC

SCHEDULE 80

2" PVC,ELECTRIC

SCHEDULE 80

2" PVC,

MHW= 1.14

2"x6" DECK

MATLACHA FISHING PIER REPLACEMENT

Page 17: REPLY TO ATTENTION OF ATTACHMENT B Documents/Matlacha F… · Fort Myers Permits Section SAJ-1990-40367 (GP-EPL) Ehab Guirguis Lee County Facilities Construction and Management 1500

TH

E

OF

FI

CI

AL

RE

CO

RD

OF

THI

S

SH

EE

T I

S

TH

E

EL

EC

TR

ONI

C

FI

LE

DI

GI

TA

LL

Y

SI

GN

ED

AN

D

SE

AL

ED

UN

DE

R

RU

LE 61

G15-23.004,

F.

A.

C.

SDS 6/19

CLH 6/19

RMW 6/19

VAZ 6/19REGISTRY NO. 27559

FORT MYERS, FL 33901

SUITE 200

2121 MCGREGOR BOULEVARD

HIGHSPANS ENGINEERING, INC.

P.E. LICENSE NUMBER 60524

VINCENT ZALIAUSKAS, P.E.

16'-0"

1'-

0"

2'-

0"

1'-

0"

10'-0"

1'-6"3'-6"3'-6"1'-6" 1'-6"6'-6"6'-6"1'-6"

8'-0"8'-0"5'-0"5'-0"

3'-

6"

"2

13'-

0

2'-

0"

3'-

6"

"2

13'-

0

"2

16'-

6

"4

12'-

7

3"

CL

R.

"2

16'-

6

"4

12'-

7"

43

10

3"

CL

R.

ATTACHED TO STRINGER

2" PVC WATERLINE

(INDEX 515-062)

PED./BICYCLE RAILING

"4

310

6"x1/4" ALUMINUM PLATE

2"x6" HANDRAIL

ATTACHED TO STRINGER

2" PVC ELECTRIC

6"x1/4" ALUMINUM PLATE

2"x6" HANDRAIL

2"x2" POST,TYPE B 2"x2" POST,TYPE B

ATTACHED TO STRINGER

2" PVC ELECTRIC

(INDEX 515-062)

PED./BICYCLE RAILING

REF. DWG. NO.

SHEET NO.

SHEET TITLE:

PROJECT NAME:

DRAWN BY:

CHECKED BY:

DESIGNED BY:

CHECKED BY:

ROAD NO. COUNTY PROJECT NO.

REVISIONS

DATE BY DESCRIPTION DATE BY DESCRIPTION

LEE

Sabrina 10/11/2019 12:27:06 PM H:\_Project18\1812_MatlachaPier\struct\B1TypicalSection01.DGN

CONSTRUCTION & MANAGEMENT

LEE COUNTY FACILITIES

T-HEAD TYPICAL SECTIONMAIN PIER TYPICAL SECTION

16'-0"

2"x10" PT STRINGERS

STRINGERS

2"x10" PT

10'-0"

PILES (TYP.)

14"x14" CONCRETE

(MA

X.)

RAILING

INSIDE FACE OF

FABRIC TIED TO

CHAIN-LINK FENCE

2"x2" BOTTOM RAIL

3" CONT. TOP RAIL

RAILING

INSIDE FACE OF

FABRIC TIED TO

CHAIN-LINK FENCE

2"x2" BOTTOM RAIL

(MA

X.)

BASE PLATE, TYPE A

2"x2" INTERMEDIATE RAIL

BASE PLATE, TYPE A

3" TOP RAIL

2"x2" INTERMEDIATE RAIL

TYPICAL SECTIONS (1 OF 3)

8

SS DECK SCREWS

ATTACHED W/ (2) #10x3" (MIN.)

GAP BETWEEN BOARDS AND

" (MAX.)212"x6" DECK BOARDS W/

SS DECK SCREWS

ATTACHED W/ (2) #10x3" (MIN.)

GAP BETWEEN BOARDS AND

" (MAX.)212"x6" DECK BOARDS W/

PILES (TYP.)

14"x14" CONCRETE

MATLACHA FISHING PIER REPLACEMENT

Page 18: REPLY TO ATTENTION OF ATTACHMENT B Documents/Matlacha F… · Fort Myers Permits Section SAJ-1990-40367 (GP-EPL) Ehab Guirguis Lee County Facilities Construction and Management 1500

WATER

TH

E

OF

FI

CI

AL

RE

CO

RD

OF

THI

S

SH

EE

T I

S

TH

E

EL

EC

TR

ONI

C

FI

LE

DI

GI

TA

LL

Y

SI

GN

ED

AN

D

SE

AL

ED

UN

DE

R

RU

LE 61

G15-23.004,

F.

A.

C.

SDS 6/19

CLH 6/19

RMW 6/19

VAZ 6/19REGISTRY NO. 27559

FORT MYERS, FL 33901

SUITE 200

2121 MCGREGOR BOULEVARD

HIGHSPANS ENGINEERING, INC.

P.E. LICENSE NUMBER 60524

VINCENT ZALIAUSKAS, P.E.

TYPICAL SECTIONS (2 OF 3)

@ HANDRAIL POSTS

DOUBLE PT BLOCKING

6'-0" O.C. (TYP.)

"8

51'-

5"

85

1'-

7"

85

1'-

7"

85

1'-

7"

85

1'-

7"

85

1'-

5

STRINGER

2"x10" PT

1'-5"1'-7"1'-7"1'-7"1'-7"1'-7"1'-7"1'-7"1'-7"1'-5"

STRINGER

2"x10" PT

2"x10" PT FASCIA

@ HANDRAIL POSTS

DOUBLE PT BLOCKING

1'-0"

HANDRAIL POST

PT BLOCKING @

8'-

0"

O.C. (T

YP.)

CONNECTION DETAIL

SEE STRINGER

CONNECTION DETAIL

SEE STRINGER

2'-2"

CONNECTION DETAIL

SEE STRINGER

PILE

CONCRETE

14"x14"

8'-0" O.C. (TYP.)

1'-

0"2'-

0"

MAIN PIER PLAN VIEW TYPICAL SECTION DETAILT-HEAD PIER PLAN VIEW TYPICAL SECTION DETAIL

TYPICAL SECTION ELEVATION VIEW DETAIL

"2

16'-

6

3'-

6"

"2

13'-

0

"4

12'-

0"

43

7

3"

CL

R.

(MA

X.)

2"x2" BOTTOM RAIL

2"x6" DECKING

WALL

8" GRAVITY

2"

3"

2'-2"

CONNECTION DETAIL

SEE STRINGER

2"x10" PT STRINGER

PILE

CONCRETE

14"x14"

8'-0" O.C. (TYP.)

1'-

0"2'-

0"

"2

16'-

6

3' -

6"

"2

13'-

0

"4

12'-

0"

43

72"

CL

R.

(MA

X.)

2"x2" BOTTOM RAILS

2"x6" DECKING

ADA COMPLIANT TYPICAL SECTION ELEVATION VIEW DETAIL

NOTCH (TYP.)

IN GRAVITY WALL

SET STRINGERS

2"x2" INTERMEDIATE RAIL

2"x2" INTERMEDIATE RAILS

16'-8"

10'-

8"

@ HANDRAIL POST

PT BLOCKING

OF INTERIOR STRINGERS

SS SCREWS AT EACH END

(3) #10x 3" (MIN.)

RAIL POST, TYPE B (TYP.)

OF EXTERIOR STRINGERS

SS SCREWS AT EACH END

(3) #12x 5" (MIN.)

PILE, CAP POST SPACING

RAIL POST, TYPE B (TYP.)RAIL POST, TYPE B (TYP.)

SHOWN FOR CLARITY

3" TOP RAIL NOT

SHOWN FOR CLARITY

3" TOP RAIL NOT

PILE, CAP POST SPACING

2"X2" POST, TYPE B (TYP.)

OF EXTERIOR STRINGERS

SS SCREWS AT EACH END

(3) #12x 5" (MIN.)

OF INTERIOR STRINGERS

SS SCREWS AT EACH END

(3) #10x 3" (MIN.)

STRINGER

2"x10" PT

NOT SHOWN FOR CLARITY)

3" TOP RAIL (HANDRAIL

CONNECTION DETAIL

SEE RAIL POST

9

REF. DWG. NO.

SHEET NO.

SHEET TITLE:

PROJECT NAME:

DRAWN BY:

CHECKED BY:

DESIGNED BY:

CHECKED BY:

ROAD NO. COUNTY PROJECT NO.

REVISIONS

DATE BY DESCRIPTION DATE BY DESCRIPTION

LEE

Sabrina 10/11/2019 12:27:08 PM H:\_Project18\1812_MatlachaPier\struct\B1TypicalSection02.DGN

CONSTRUCTION & MANAGEMENT

LEE COUNTY FACILITIES

MATLACHA FISHING PIER REPLACEMENT

Page 19: REPLY TO ATTENTION OF ATTACHMENT B Documents/Matlacha F… · Fort Myers Permits Section SAJ-1990-40367 (GP-EPL) Ehab Guirguis Lee County Facilities Construction and Management 1500

TH

E

OF

FI

CI

AL

RE

CO

RD

OF

THI

S

SH

EE

T I

S

TH

E

EL

EC

TR

ONI

C

FI

LE

DI

GI

TA

LL

Y

SI

GN

ED

AN

D

SE

AL

ED

UN

DE

R

RU

LE 61

G15-23.004,

F.

A.

C.

SDS 6/19

CLH 6/19

RMW 6/19

VAZ 6/19REGISTRY NO. 27559

FORT MYERS, FL 33901

SUITE 200

2121 MCGREGOR BOULEVARD

HIGHSPANS ENGINEERING, INC.

P.E. LICENSE NUMBER 60524

VINCENT ZALIAUSKAS, P.E.

(INDEX 515-062)

PED./BICYCLE RAILING

2"x2" POST, TYPE B

REF. DWG. NO.

SHEET NO.

SHEET TITLE:

PROJECT NAME:

DRAWN BY:

CHECKED BY:

DESIGNED BY:

CHECKED BY:

ROAD NO. COUNTY PROJECT NO.

REVISIONS

DATE BY DESCRIPTION DATE BY DESCRIPTION

LEE

Sabrina 10/11/2019 12:27:09 PM H:\_Project18\1812_MatlachaPier\struct\B1TypicalSection03.DGN

CONSTRUCTION & MANAGEMENT

LEE COUNTY FACILITIES

TYPICAL SECTIONS (3 OF 3)

4'-2"

1" 1"

1'-6"6'-0"

1'-

0"

1'-

0"

RAMP TYPICAL SECTION

MAIN PIER AND T-HEAD CONNECTION DETAIL

T-HEAD

1'-

0"

T-HEAD1'-6"6'-0"

1'-

0"

4'-2"

1" 1"

RAILING

POST (TYP.)

RAILING

RAILING

POST (TYP.)

RAILING

2'-

2"

PILE C

AP

2'-2" PILE CAP 2'-2" PILE CAP

2'-

2"

PILE C

AP

HANDRAIL POST

PT BLOCKING @

CONNECTION DETAIL

SEE INTERIOR STRINGER

CONNECTION DETAIL

SEE EXTERIOR STRINGER

STRINGER

2"x10" PT

2" GAP

5"

4'-

10"

5"

@ HANDRAIL POST

DOUBLE PT BLOCKING

ATTACHED TO RAILING

MONOFILAMENT BIN

4'-0" CLEANING STATION

2'-

0"

CLE

ANIN

G

ST

ATIO

N

ST

ATIO

N

2'-

0"

CLE

ANIN

G

4'-0" CLEANING STATION

ATTACHED TO RAILING

MONOFILAMENT BIN

(INDEX 400-011)

GRAVITY WALL

SEE CONNECTION DETAIL

8" 8"

"4

12'-

7"

43

10

OF INTERIOR STRINGERS

SS SCREWS AT EACH END

(3) #10x 3" (MIN.)

OF INTERIOR STRINGERS

SS SCREWS AT EACH END

(3) #12x 5" (MIN.)

ATTACHED TO RAILING

FISH DISPOSAL TUBE

ATTACHED TO RAILING

FISH DISPOSAL TUBE

2"x2" INTERMEDIATE RAIL

RAILING

INSIDE FACE OF

FABRIC TIED TO

CHAIN-LINK FENCE

3'-

6"

2'-

3"

2'-

0" (M

IN.)

"214'-11"2

14'-11

CONCRETE SIDEWALK

4" THICK

3" TOP RAIL

2"x2" BOTTOM RAIL

BASE PLATE, TYPE A

10 MATLACHA FISHING PIER REPLACEMENT

Page 20: REPLY TO ATTENTION OF ATTACHMENT B Documents/Matlacha F… · Fort Myers Permits Section SAJ-1990-40367 (GP-EPL) Ehab Guirguis Lee County Facilities Construction and Management 1500

TH

E

OF

FI

CI

AL

RE

CO

RD

OF

THI

S

SH

EE

T I

S

TH

E

EL

EC

TR

ONI

C

FI

LE

DI

GI

TA

LL

Y

SI

GN

ED

AN

D

SE

AL

ED

UN

DE

R

RU

LE 61

G15-23.004,

F.

A.

C.

SDS 6/19

CLH 6/19

RMW 6/19

VAZ 6/19REGISTRY NO. 27559

FORT MYERS, FL 33901

SUITE 200

2121 MCGREGOR BOULEVARD

HIGHSPANS ENGINEERING, INC.

P.E. LICENSE NUMBER 60524

VINCENT ZALIAUSKAS, P.E.

EACH PILE

2-4MC01 @

@ 6" O.C.

4MC02

4MC03

4MC03

4MC03

4MC03

4MC03

4MC04

4MC04

4MC04

4MC04

3-4MC05

3-4MC05

4MC06 @ 6" O.C.

4MC06 @ 6" O.C.

PILE DOWELS

2-8MC10

EACH PILE

2-4MC01 @ 3" O.C.

12-4MC02 @ 6" O.C.

12-4MC02 @ 6" O.C.

EACH PILE

2-4MC01 @ 3" O.C.

PILE DOWELS

2-8MC0. @ 7" O.C.

PILE DOWELS

2-8MC07 @ 7" O.C.

@ 5" O.C.2-4MC02

@ 5" O.C.2-4MC02

REF. DWG. NO.

SHEET NO.

SHEET TITLE:

PROJECT NAME:

DRAWN BY:

CHECKED BY:

DESIGNED BY:

CHECKED BY:

ROAD NO. COUNTY PROJECT NO.

REVISIONS

DATE BY DESCRIPTION DATE BY DESCRIPTION

LEE

Sabrina 10/11/2019 12:27:09 PM H:\_Project18\1812_MatlachaPier\struct\B1TypicalSection04.DGN

CONSTRUCTION & MANAGEMENT

LEE COUNTY FACILITIES

PILES

¡ CAP &

4" CLR.

(TYP.)

2'-

0"

PILES

¡ CAP &

14"x14" CONCRETE PILE

10'-0"

2'-

2"

10'-0"

2'-

0"

PILE CAP DETAILS (1 OF 2)

14"x14" CONCRETE PILE14"x14" CONCRETE PILE

2'-2"

1'-1"1'-1"(TYP.)

" CHAMFER43

2'-2"

1'-1"1'-1"(TYP.)

" CHAMFER43

2'-

0"

4" CLR.

(TYP.)

MAIN PIER PILE CAP PLAN VIEW

MAIN PIER PILE CAP ELEVATION VIEW

CAP DETAIL BETWEEN PILES

CAP DETAIL AT PILES

11 MATLACHA FISHING PIER REPLACEMENT

Page 21: REPLY TO ATTENTION OF ATTACHMENT B Documents/Matlacha F… · Fort Myers Permits Section SAJ-1990-40367 (GP-EPL) Ehab Guirguis Lee County Facilities Construction and Management 1500

TH

E

OF

FI

CI

AL

RE

CO

RD

OF

THI

S

SH

EE

T I

S

TH

E

EL

EC

TR

ONI

C

FI

LE

DI

GI

TA

LL

Y

SI

GN

ED

AN

D

SE

AL

ED

UN

DE

R

RU

LE 61

G15-23.004,

F.

A.

C.

SDS 6/19

CLH 6/19

RMW 6/19

VAZ 6/19REGISTRY NO. 27559

FORT MYERS, FL 33901

SUITE 200

2121 MCGREGOR BOULEVARD

HIGHSPANS ENGINEERING, INC.

P.E. LICENSE NUMBER 60524

VINCENT ZALIAUSKAS, P.E.

EACH PILE

2-4TC01 @

EACH PILE

2-4TC01 @

2-4TC02

2-4TC022-4TC02

4TC03 4TC04

4TC044TC06 @ 6" O.C. PILE DOWELS

2-8TC07

PILE DOWELS

2-8TC074TC06 @ 6" O.C.

8-4CC02 2-4CC026-4CC02

4CC03PILE DOWELS

2-8CC074CC06 @ 6" O.C.

EACH PILE

2-4CC01 @

@ 6" O.C.

4TC02/4CC02

4TC03/4CC03

4TC03/4CC03

4TC03/4CC03

4CC04

4TC04/4CC04

4TC04/4CC04

3-4CC05 3-4CC053-4CC08

PILE DOWELS

2-8TC07/8CC07

@ EACH PILE

2-4TC01/4CC01

3-4TC05/4CC05/4CC08

11-4TC02

11-4TC02@ 5" O.C.2-4TC02

ANCHOR BOLTS

17x3x3/4" GS

@ 6" O.C.

4MEC06/4TEC06

@ 5" O.C.

6-4MEC02/4TEC02

EACH PILE

@ 3" O.C.

2-4MEC01/4TEC01

4MEC04/4TEC04

4TC05

4MEC05/4TEC05

6-4TC03/4CC03

11-4TC02 @ 6" O.C.

11-4TC02 @ 6" O.C.

8-4CC02 @ 6" O.C.

REF. DWG. NO.

SHEET NO.

SHEET TITLE:

PROJECT NAME:

DRAWN BY:

CHECKED BY:

DESIGNED BY:

CHECKED BY:

ROAD NO. COUNTY PROJECT NO.

REVISIONS

DATE BY DESCRIPTION DATE BY DESCRIPTION

LEE

Sabrina 10/11/2019 12:27:10 PM H:\_Project18\1812_MatlachaPier\struct\B1TypicalSection05.DGN

CONSTRUCTION & MANAGEMENT

LEE COUNTY FACILITIES

2'-

0"

14"x14" CONCRETE PILE

2'-

2"

2'-

0"

T-HEAD PILE CAP PLAN VIEW

CAP DETAIL AT PILES

(TYP.)

" CHAMFER43

(TYP.)

" CHAMFER43

16'-0"

T-HEAD PILE CAP ELEVATION VIEW

1'-6"6'-6"6'-6"1'-6"

1'-6"6'-6"6'-6"1'-6"

2'-2"

4" CLR. (TYP.)

T-HEAD PILE CAP @ MAIN PIER CONNECTION SIMILAR

14'-11"

14"x14" CONCRETE PILE

1'-6"5'-0"5'-0"3'-5"

14"x14" CONCRETE PILE

T-HEAD PILE CAP @ MAIN PIER CONNECTION ELEVATION VIEW

PILES

¡ CAP &

4" CLR. (TYP.)

1'-1"1'-1"

2'-2"

1'-1"1'-1"

PILE CAP DETAILS (2 OF 2)

¡ CAP

LIGHT POLE DETAIL

2'-

0"

3'-6"

11"

12

(SIMILAR TO T-HEAD)

SHOWN FOR MAIN PIER

CAP EXTENSION DETAILS

LIGHT POLE

12'x4"x1/8" ALUMINUM

CAP DETAIL BETWEEN PILES

MATLACHA FISHING PIER REPLACEMENT

Page 22: REPLY TO ATTENTION OF ATTACHMENT B Documents/Matlacha F… · Fort Myers Permits Section SAJ-1990-40367 (GP-EPL) Ehab Guirguis Lee County Facilities Construction and Management 1500

MAIN PIER LOOKING SOUTH

MAIN PIER LOOKING NORTH

MAIN PIER LOOKING EAST

TH

E

OF

FI

CI

AL

RE

CO

RD

OF

THI

S

SH

EE

T I

S

TH

E

EL

EC

TR

ONI

C

FI

LE

DI

GI

TA

LL

Y

SI

GN

ED

AN

D

SE

AL

ED

UN

DE

R

RU

LE 61

G15-23.004,

F.

A.

C.

SDS 6/19

CLH 6/19

RMW 6/19

VAZ 6/19REGISTRY NO. 27559

FORT MYERS, FL 33901

SUITE 200

2121 MCGREGOR BOULEVARD

HIGHSPANS ENGINEERING, INC.

P.E. LICENSE NUMBER 60524

VINCENT ZALIAUSKAS, P.E.

2'-2"

2'-

0"

STRINGER

2"x10" PT

CLEANING STATION ELEVATION VIEW

ADA COMPLIANT CLEANING STATION ELEVATION VIEW

3'-

6"

PILE & CAP

CONCRETE

EXISTING GROUND

(INDEX 515-062)

RAILING, TYPE 2

1'-4"4'-0"8"

"212 "2

12

DECKING

2"x6"

WATERLINE

SCHEDULE 80

2" PVC,

3"

3"

TO RAIL

WATERLINE

ATTACH

TABLE POST

2"x2" ALUMINUM

CLEANING STATION TABLE

FAUCET

DISPOSAL TUBE

8" PVC FISH

2'-

0"

2'-2"

2'-

0"

3'-

6"

EXISTING GROUND

1'-4" 4'-0" 8"

"212"2

12

3"

3"

CLEANING STATION TABLE

FAUCET

2'-

0"

(INDEX 515-062)

RAILING, TYPE 2

TO RAIL

WATERLINE

ATTACH

TALBE POST

2"x2" ALUMINUM

9"

1'-

4"

2'-

5"

EXISTING GROUND

DISPOSAL TUBE

8" PVC FISH

WATERLINE

SCHEDULE 80

2" PVC,

PILE & CAP

CONCRETE

STRINGER

2"x10" PT

DECKING

2"x6"

2'-0"

2" 1'-3"10"

7"

1" 1"

"2

1"

21

"2

12'-

5

1"

4"3"

9"

2'-

5"

7"

1'-0"

2"

POST

ALUMINUM

2"x2"

TO RAIL

WATERLINE

ATTACH

RAIL

2"x2"

RAIL

2"x2"

WATERLINE

SCHEDULE 80

2" PVC,STRINGER

2"x10" PT

DECKING

2"x6"

2'-0"

2"

1"1"

"2

1"

21

"2

13'-

6

1"

4" 3"

3"

3'-

6"

7"

1'-0"

TO RAIL

WATERLINE

ATTACH

POST

ALUMINUM

2"x2"

RAIL

2"x2"

"211

"217

"211'-2 10"

WATERLINE

SCHEDULE 80

2" PVC,

RAIL

2"x2"DECKING

2"x6"

RAIL

3" DIA.

CLEANING STATION TYPICAL SECTION

TO RAIL

WATERLINE

ATTACH

TO RAIL

WATERLINE

ATTACH

TO RAIL POST

ATTACH TUBE

TO RAIL POST

ATTACH TUBE

FISH DISPOSAL TUBE DETAIL

RAILING OUTLINE

DECKING

2"x6"

STRINGER

2"x10" PT

DISPOSAL TUBE

8" PVC FISH

CLEANING STATION DETAILS

13

FILLET WELD.

"41WELDED WITH

" ALUMINUM PLATE 41

REF. DWG. NO.

SHEET NO.

SHEET TITLE:

PROJECT NAME:

DRAWN BY:

CHECKED BY:

DESIGNED BY:

CHECKED BY:

ROAD NO. COUNTY PROJECT NO.

REVISIONS

DATE BY DESCRIPTION DATE BY DESCRIPTION

LEE

Sabrina 10/11/2019 12:27:11 PM H:\_Project18\1812_MatlachaPier\struct\B1TypicalSection06.DGN

CONSTRUCTION & MANAGEMENT

LEE COUNTY FACILITIES

MATLACHA FISHING PIER REPLACEMENT

Page 23: REPLY TO ATTENTION OF ATTACHMENT B Documents/Matlacha F… · Fort Myers Permits Section SAJ-1990-40367 (GP-EPL) Ehab Guirguis Lee County Facilities Construction and Management 1500

TH

E

OF

FI

CI

AL

RE

CO

RD

OF

THI

S

SH

EE

T I

S

TH

E

EL

EC

TR

ONI

C

FI

LE

DI

GI

TA

LL

Y

SI

GN

ED

AN

D

SE

AL

ED

UN

DE

R

RU

LE 61

G15-23.004,

F.

A.

C.

SDS 6/19

CLH 6/19

RMW 6/19

VAZ 6/19REGISTRY NO. 27559

FORT MYERS, FL 33901

SUITE 200

2121 MCGREGOR BOULEVARD

HIGHSPANS ENGINEERING, INC.

P.E. LICENSE NUMBER 60524

VINCENT ZALIAUSKAS, P.E. REF. DWG. NO.

SHEET NO.

SHEET TITLE:

PROJECT NAME:

DRAWN BY:

CHECKED BY:

DESIGNED BY:

CHECKED BY:

ROAD NO. COUNTY PROJECT NO.

REVISIONS

DATE BY DESCRIPTION DATE BY DESCRIPTION

LEE

Sabrina 10/11/2019 12:27:12 PM H:\_Project18\1812_MatlachaPier\struct\B1TypicalSection07.DGN

CONSTRUCTION & MANAGEMENT

LEE COUNTY FACILITIES

STRINGER

(2) 2"x10" PT

EXTERIOR STRINGER CONNECTION DETAIL

2"x6" DECK

PILE CAP

CONCRETE

2"x6" DECK

PILE CAP

CONCRETE

"41

"4

1

"41"4

1

"4

1

INTERIOR STRINGER CONNECTION DETAIL

STRINGER

2"x10" PT

FILL

SIDEWALK

CONCRETE

4" THICK

POST CONNECTION TO GRAVITY WALL DETAIL

EPOXY BONDED TO CAP

"x8" LONG SS BOLT83

" HOLE167

SS BOLT

" LONG21"x38

3(2)

" HOLE167

5" LONG SS ANGLE

" THICK413"x4"x

" SS DECK SCREW21(2) #10x3

2"x6" DECKING ATTACHED W/

5" LONG SS ANGLE

" THICK413"x4"x

SS PLATE

" THICK41"x5"x2

18

5" LONG SS ANGLE

" THICK854"x8"x

" SS DECK SCREW21(2) #10x3

2"x6" DECKING ATTACHED W/

EPOXY BONDED TO CAP

"x8" LONG SS BOLT83

" HOLE167

SS PLATE

" THICK418"x5"x

SS BOLT

"x6" LONG43

" HOLE87(2)

PIER DETAILS

AND HANGER ASSEMBLY

2" PVC WATERLINE CONDUIT

¡ BOLT & POST

Ɓ" ℅ Stiffener

2"x6" DECKING

STRINGER

2"x10" PT

1"

1"

SS BOLT

"x6" LONG43

(INDEX 400-011)

GRAVITY WALL

(INDEX 515-062)

RAILING

(INDEX 515-062)

RAILING

HANDRAIL AND ROD HOLDER CONNECTION DETAIL

POST CONNECTION TO STRINGER DETAIL

(INDEX 515-061)

SUPPORT BRACKET, SCHEME 3

(INDEX 515-062)

RAILING

HANDRAIL

2"x6" TANDECK

WELDED TO 3" DIA. TOP RAIL

" ALUMINUM PLATE416"x

3" DIA. TOP RAIL

BOLTS @ 18" O.C.

" SS MUSHROOM41

8"

(INDEX 515-062)

CASE IIb

RAILING CONNECTION,

14

TERMINATION (TYP.)

" (MAX.) WELD21

AND EAST SIDE OF THE T-HEAD PIER

EACH ALUMINUM POST ON THE NORTH, SOUTH

ALUMINUM ROD HOLDER WELDED TO

MATLACHA FISHING PIER REPLACEMENT

Page 24: REPLY TO ATTENTION OF ATTACHMENT B Documents/Matlacha F… · Fort Myers Permits Section SAJ-1990-40367 (GP-EPL) Ehab Guirguis Lee County Facilities Construction and Management 1500

TH

E

OF

FI

CI

AL

RE

CO

RD

OF

THI

S

SH

EE

T I

S

TH

E

EL

EC

TR

ONI

C

FI

LE

DI

GI

TA

LL

Y

SI

GN

ED

AN

D

SE

AL

ED

UN

DE

R

RU

LE 61

G15-23.004,

F.

A.

C.

SDS 6/19

CLH 6/19

RMW 6/19

VAZ 6/19REGISTRY NO. 27559

FORT MYERS, FL 33901

SUITE 200

2121 MCGREGOR BOULEVARD

HIGHSPANS ENGINEERING, INC.

P.E. LICENSE NUMBER 60524

VINCENT ZALIAUSKAS, P.E. REF. DWG. NO.

SHEET NO.

SHEET TITLE:

PROJECT NAME:

DRAWN BY:

CHECKED BY:

DESIGNED BY:

CHECKED BY:

ROAD NO. COUNTY PROJECT NO.

REVISIONS

DATE BY DESCRIPTION DATE BY DESCRIPTION

LEE

Sabrina 10/11/2019 12:27:12 PM H:\_Project18\1812_MatlachaPier\struct\B1RebarList01.dgn

CONSTRUCTION & MANAGEMENT

LEE COUNTY FACILITIES

REINFORCING BAR LIST

15 MATLACHA FISHING PIER REPLACEMENT

Page 25: REPLY TO ATTENTION OF ATTACHMENT B Documents/Matlacha F… · Fort Myers Permits Section SAJ-1990-40367 (GP-EPL) Ehab Guirguis Lee County Facilities Construction and Management 1500

ATTACHMENT II

Page 26: REPLY TO ATTENTION OF ATTACHMENT B Documents/Matlacha F… · Fort Myers Permits Section SAJ-1990-40367 (GP-EPL) Ehab Guirguis Lee County Facilities Construction and Management 1500

Dated 9/18/2019

SELF-CERTIFICATION STATEMENT OF COMPLIANCE Within sixty (60) days of completion of the authorized work, submit this form via electronic mail to [email protected] (preferred, not to exceed 15MB) or by standard mail to U.S. Army Corps of Engineers, Enforcement Section, P.O. Box 4970, Jacksonville, FL 32232-0019.

1. Department of the Army Permit Number: SAJ-______-______ (_____-____)

2. Permittee Information: Name: ____________________________________________

Email: ____________________________________________

Address: __________________________________________

__________________________________________

Phone: ___________________________________________

3. Date Authorized Work Started: _________________ Completed: _______________

4. Contact to Schedule Inspection: Name: ____________________________________

Email: ____________________________________

Phone: ___________________________________

5. Description of Authorized Work (e.g. bank stabilization, fill placed within wetlands, docks, dredging, etc.): ________________________________________________________

____________________________________________________________________________

____________________________________________________________________________

6. Acreage or Square Feet of Impacts to Waters of the United States: _________________

7. Describe Mitigation completed (if applicable): __________________________________

____________________________________________________________________________

____________________________________________________________________________

8. Describe any Deviations from Permit (attach drawing(s) depicting the deviations):

____________________________________________________________________________

____________________________________________________________________________ ********************

I certify that all work and mitigation (if applicable) was done in accordance with the limitations and conditions as described in the permit. Any deviations as described above are depicted on the attached drawing(s).

______________________________ Signature of Permittee ______________________________ Printed Name of Permittee

______________________________ Date

Page 27: REPLY TO ATTENTION OF ATTACHMENT B Documents/Matlacha F… · Fort Myers Permits Section SAJ-1990-40367 (GP-EPL) Ehab Guirguis Lee County Facilities Construction and Management 1500

ATTACHMENT III

Page 28: REPLY TO ATTENTION OF ATTACHMENT B Documents/Matlacha F… · Fort Myers Permits Section SAJ-1990-40367 (GP-EPL) Ehab Guirguis Lee County Facilities Construction and Management 1500

Dated 9/18/2019

COMMENCEMENT NOTIFICATION

Within ten (10) days of initiating the authorized work, submit this form via electronic mail to [email protected] (preferred, not to exceed 15 MB) or by standard mail to U.S. Army Corps of Engineers, Enforcement Section, P.O. Box 4970, Jacksonville, FL 32232-0019. 1. Department of the Army Permit Number: SAJ-_____-______(_____-____) 2. Permittee Information: Name: __________________________________________ Email: __________________________________________ Address: __________________________________________ __________________________________________ Phone: __________________________________________ 3. Construction Start Date: ______________________ 4. Contact to Schedule Inspection:

Name: __________________________________________ Email: __________________________________________ Phone: __________________________________________

______________________________ Signature of Permittee ______________________________ Printed Name of Permittee

______________________________ Date

Page 29: REPLY TO ATTENTION OF ATTACHMENT B Documents/Matlacha F… · Fort Myers Permits Section SAJ-1990-40367 (GP-EPL) Ehab Guirguis Lee County Facilities Construction and Management 1500

ATTACHMENT IV

Page 30: REPLY TO ATTENTION OF ATTACHMENT B Documents/Matlacha F… · Fort Myers Permits Section SAJ-1990-40367 (GP-EPL) Ehab Guirguis Lee County Facilities Construction and Management 1500

U.S. Army Corps of Engineers Jacksonville District's Programmatic Biological Opinion (JaxBO) Project Design Criteria (PDCs) for In-Water Activities

November 20, 2017

1) (AP.7.) Education and Observation: The permittee must ensure that all personnel

associated with the project are instructed about the potential presence of species protected under the ESA and the Marine Mammal Protection Act (MMPA). All on-site project personnel are responsible for observing water-related activities for the presence of protected species. All personnel shall be advised that there are civil and criminal penalties for harming, harassing, or killing ESA-listed species or marine mammals. To determine which species may be found in the project area, please review the relevant Protected Species List at: http://sero.nmfs.noaa.gov/protected_resources/section_7/threatened_endangered/index.html

2) (AP.8.) Reporting of interactions with protected species: a) Any collision(s) with and/or injury to any sea turtle, sawfish, whale, or sturgeon

occurring during the construction of a project, shall be reported immediately to NMFS’s Protected Resources Division (PRD) at (1-727-824-5312) or by email to [email protected] and [email protected].

b) Smalltooth sawfish: Report sightings to 1-844-SAWFISH or email [email protected]

c) Sturgeon: Report dead sturgeon to 1-844-STURG 911 (1-844-788-7491) or email [email protected]

d) Sea turtles and marine mammals: Report stranded, injured, or dead animals to 1-877-WHALE HELP (1-877-942-5343).

e) North Atlantic right whale: Report injured, dead, or entangled right whales to the USCG via VHF Channel 16.

3) (AP.9.) Vessel Traffic and Construction Equipment: All vessel operators must

watch for and avoid collision with species protected under the ESA and MMPA. Vessel operators must avoid potential interactions with protected species and operate in accordance with the following protective measures: a) Construction Equipment:

i) All vessels associated with the construction project shall operate at “Idle Speed/No Wake” at all times while operating in water depths where the draft of the vessel provides less than a 4-foot (ft) clearance from the bottom, and in all depths after a protected species has been observed in and has departed the area.

ii) All vessels will follow marked channels and/or routes using the maximum water depth whenever possible.

iii) Operation of any mechanical construction equipment, including vessels, shall cease immediately if a listed species is observed within a 50-ft radius of

Page 31: REPLY TO ATTENTION OF ATTACHMENT B Documents/Matlacha F… · Fort Myers Permits Section SAJ-1990-40367 (GP-EPL) Ehab Guirguis Lee County Facilities Construction and Management 1500

construction equipment and shall not resume until the species has departed the area of its own volition.

iv) If the detection of species is not possible during certain weather conditions (e.g., fog, rain, wind), then in-water operations will cease until weather conditions improve and detection is again feasible.

b) All Vessels: i) Sea turtles: Maintain a minimum distance of 150 ft. ii) North Atlantic right whale: Maintain a minimum 1,500-ft distance (500 yards). iii) Vessels 65 ft in length or longer must comply with the Right Whale Ship Strike

Reduction Rule (50 CFR 224.105) which includes reducing speeds to 10 knots or less in Seasonal Management Areas (http://www.fisheries.noaa.gov/pr/shipstrike/).

iv) Mariners shall check various communication media for general information regarding avoiding ship strikes and specific information regarding right whale sightings in the area. These include NOAA weather radio, USCG NAVTEX broadcasts, and Notices to Mariners.

v) Marine mammals (i.e., dolphins, whales [other than North Atlantic right whales], and porpoises): Maintain a minimum distance of 300 ft.

vi) When these animals are sighted while the vessel is underway (e.g., bow-riding), attempt to remain parallel to the animal’s course. Avoid excessive speed or abrupt changes in direction until they have left the area.

vii) Reduce speed to 10 knots or less when mother/calf pairs or groups of marine mammals are observed, when safety permits.

4) (AP.10.) Turbidity Control Measures during Construction: Turbidity must be

monitored and controlled. Prior to initiating any of the work covered under this Opinion, the Permittee shall install turbidity curtains as described below. In some instances, the use of turbidity curtains may be waived by the USACE project manager if the project is deemed too minimal to generate turbidity (e.g., certain ATON installation, scientific survey device placement, marine debris removal) or if the current is too strong for the curtains to stay in place. Turbidity curtains specifications: a) Install floating turbidity barriers with weighted skirts that extend to within 1 ft of

the bottom around all work areas that are in, or adjacent to, surface waters. b) Use these turbidity barriers throughout construction to control erosion and

siltation and ensure that turbidity levels within the project area do not exceed background conditions.

c) Position turbidity barriers in a way that does not block species’ entry to or exit from designated critical habitat.

d) Monitor and maintain turbidity barriers in place until the authorized work has been completed and the water quality in the project area has returned to background conditions.

e) In the range of ESA-listed corals (St. Lucie Inlet, Martin County south to the Dry Tortugas and the U.S. Caribbean) and Johnson’s seagrass (Turkey Creek/Palm

Page 32: REPLY TO ATTENTION OF ATTACHMENT B Documents/Matlacha F… · Fort Myers Permits Section SAJ-1990-40367 (GP-EPL) Ehab Guirguis Lee County Facilities Construction and Management 1500

Bay south to central Biscayne Bay in the lagoon systems on the east coast of Florida): i) Projects that include upland earth moving (e.g., grading to install a building or

parking lot associated with a dock and seawall project), must install sediment control barriers to prevent any upland sediments from reaching estuarine or marine waters.

ii) The turbidity curtain requirement cannot be waived for any project that moves or removes sediment (e.g., dredging, auger to create a pile, trenching to install a cableline). If turbidity curtains are not feasible in an area based on site conditions such as water current, high wave action, or stormy conditions, the project must undergo individual Section 7 consultation and is not covered under this Programmatic Opinion.

5) (AP.11.) Entanglement: All turbidity curtains and other in-water equipment must be

properly secured with materials that reduce the risk of entanglement of marine species (described below). Turbidity curtains likewise must be made of materials that reduce the risk of entanglement of marine species. a) In-water lines (rope, chain, and cable, including the lines to secure turbidity

curtains) must be stiff, taut, and non-looping. Examples of such lines are heavy metal chains or heavy cables that do not readily loop and tangle. Flexible in-water lines, such as nylon rope or any lines that could loop or tangle, must be enclosed in a plastic or rubber sleeve/tube to add rigidity and prevent the line from looping and tangling. In all instances, no excess line is allowed in the water.

b) Turbidity curtains and other in-water equipment must be placed in a manner that does not entrap species within the construction area or block access for them to navigate around the construction area.

Page 33: REPLY TO ATTENTION OF ATTACHMENT B Documents/Matlacha F… · Fort Myers Permits Section SAJ-1990-40367 (GP-EPL) Ehab Guirguis Lee County Facilities Construction and Management 1500

Project Design Criteria (PDCs) Specific to Activity 2 for Pile-Supported Structures and Anchored Buoys

A2.1. Activities covered by this Opinion include the installation, repair, replacement, and

removal of structures as described below: A2.1.1. The pile-supported and anchored structures included in this Opinion are:

docks and piers, boatlifts, mooring piles and dolphin piles associated with docks/piers; ATONs and PATONs; floating docks; pile-supported chickees (i.e., small, back-country, over-water, pile-supported, primitive camping shelters); boardwalks (as long as they are designed and clearly marked to prohibit fishing and vessel mooring); mooring fields and buoys; and other minor pile-supported structures. This does not include structures that support large commercial vessels including ferries, tankers, and cargo ships such as ferry terminals and large ports.

A2.1.2. Pile-supported docks/piers for a single-family residential lot are limited to 4 slips for motorized vessels. Slips for non-motorized vessels (e.g., kayak, canoe, and paddleboard) and associated launching areas do not count toward the total slip number.

A2.1.3. Pile-supported structures for marinas, multi-family facilities (e.g., condo complexes, trailer parks, subdivisions when the homeowners association owns and controls the in-water structures). Docks and piers for multi-family residential properties (e.g., condos, trailer parks, apartment complexes), and marinas are limited to a maximum of 50 total slips (i.e., combination of wet and dry slips for existing plus proposed slips).

A2.1.4. Anchored buoys and temporary pile-supported structures associated with marine events. Upon completion of the event, these structures must be removed and, to the maximum extent practical, the site must be restored to pre-construction elevations. Water depths in the area of marine events must be deep enough to support at least 5 ft of water depth under the keel of a vessel and between the keel of a vessel and ESA-listed coral colonies when transiting to the mooring areas. There is no limit on the number of vessel slips allowed for temporary structures associated marine events such as boat shows.

A2.1.5. Mooring fields are limited to a maximum of 50 motorized vessels (there is no limit on the number of non-motorized vessels).

A2.1.6. All pile-supported structures constructed must comply with PDC 2.17 for Docks or Other Minor Structures Constructed in Florida Under this Opinion (see below).

The following PDCs apply to all the activities described in PDC A2.1 above: A2.2. For commercial, multi-family, or public facilities, and marine events, signs must be

posted in a visible location(s), alerting users of listed species in the area susceptible to vessel strikes and hook-and-line captures. The most current version of the signs that must be downloaded and sign installation guidance are available at: (http://sero.nmfs.noaa.gov/protected_resources/section_7/protected_species_educational_signs/index.html). The signs required to be posted by area are stated below:

A2.2.1. All projects in Florida shall use the Save Sea Turtle, Sawfish, and Dolphin sign. These signs shall include contact information to the sea turtle and marine

Page 34: REPLY TO ATTENTION OF ATTACHMENT B Documents/Matlacha F… · Fort Myers Permits Section SAJ-1990-40367 (GP-EPL) Ehab Guirguis Lee County Facilities Construction and Management 1500

mammal stranding networks and smalltooth sawfish encounter database. A2.2.2. Projects within the North Atlantic right whale educational sign zone (as

defined in Section 2.1.1.4) shall post the Help Protect North Atlantic Right Whales sign.

A2.2.3. On the east coast of Florida, projects located within the St. John’s River and those occurring north of the St. Johns River to the Florida-Georgia line shall post the Report Sturgeon sign. On the west coast of Florida, projects occurring from the Cedar Key, Florida north to the Florida-Alabama line.

A2.2.4. We are still developing the signs to be used in the U.S. Caribbean. Once developed, those signs will be included at the website above.

A2.3. For commercial, multi-family, or public facilities, monofilament recycling bins must be

provided at the docking facility to reduce the risk of turtle or sawfish entanglement in, or ingestion of, marine debris. Monofilament recycling bins must: A2.3.1. Be constructed and labeled according to the instructions

provided at http://mrrp.myfwc.com. A2.3.2. Be maintained in working order and emptied frequently (according to

http://mrrp.myfwc.com standards) so that they do not overflow.

A2.4. For any dock project (new construction, repair, or replacement) at a private residence located within 11 nautical miles of North Atlantic right whale critical habitat (as measured in a radius from the center of the nearest inlet to open ocean and described in Section 2.1.1.4), the property owner will be provided a handout with their USACE permit describing the presence of North Atlantic right whales in the area and the Federal regulations governing the approach to North Atlantic right whales (Appendix C).

A2.5. ATONs and PATONs must be approved by and installed in accordance with the

requirements of the USCG (see 33 CFR, chapter I, subchapter C, part 66 and RHA Section 10 and any other pertinent requirements).

A2.6. Chickees must be less than 500 ft² and support no more than 2 slips.

A2.7. No activities associated with municipal or commercial fishing piers are covered

under this Opinion.

A2.8. Docks installed within visible distance of ocean beaches are required to comply with turtle-friendly lighting, if lighting is necessary to the project. Turtle-friendly lighting is explained and examples are provided on the Florida Fish and Wildlife Conservation Commission website: http://myfwc.com/wildlifehabitats/managed/sea-turtles/lighting/

A2.9. Project construction will take place from uplands or from floating equipment (e.g.,

barge); prop or wheel-washing is prohibited.

Page 35: REPLY TO ATTENTION OF ATTACHMENT B Documents/Matlacha F… · Fort Myers Permits Section SAJ-1990-40367 (GP-EPL) Ehab Guirguis Lee County Facilities Construction and Management 1500

Additional PDCs for Activity 2 applicable in Critical Habitat

A2.10. Acropora critical habitat and the U.S. Caribbean: This Opinion does not cover new and expanded pile-supported structures in Acropora critical habitat where the essential features are present. The distance from ATONs to ESA-listed corals and Acropora critical habitat shall ensure there are no impacts to the corals or the essential feature of Acropora critical habitat from the movement of buoys and tackle. The appropriate distance shall be based on the size of the anchor chain or other tackle to be installed to secure the buoy to its anchor, particularly when the design of the ATON does not prohibit contact of tackle with the marine bottom. In all cases, buoy tackle will include flotation to ensure there is no contact between the anchor chain or line and the marine bottom.

A2.11. Gulf sturgeon critical habitat: Additional noise restrictions are required for pile and sheet

pile installation in the Gulf sturgeon critical habitat migratory restriction zones defined in Section 2.1.1.2. The noise restrictions are described in that section.

A2.12. Smalltooth sawfish critical habitat: This Opinion does not cover activities occurring in areas

identified as smalltooth sawfish limited exclusion zones defined in Section 2.1.1.1.

A2.13. North Atlantic right whale critical habitat: This Opinion does not cover installation of anchored ATONs and permanent buoys in North Atlantic right whale critical habitat; temporary buoys for marine events are allowed in North Atlantic right whale critical habitat.

A2.14. Johnson’s seagrass critical habitat: This Opinion does not cover new marinas or multi-

family facilities in Johnson’s seagrass critical habitat. Repair, replacement, and reconfiguration of existing marinas or multi-family facilities may be covered if it (1) occurs within same overall footprint (out to the perimeter of the facility, including the outer limits of the structure and permitted mooring locations), (2) does not increase the total aerial extent (i.e., area of coverage from the dock structures) of the existing facility, and (3) does not affect Johnson’s seagrass. Mooring fields are allowed in Johnson’s seagrass critical habitat and within the range of Johnson’s seagrass so long as they occur in waters deeper than -13 ft (-4 m).

A2.15. NWA DPS of loggerhead sea turtle critical habitat: ATONs (pile-supported and anchored

buoys) are allowed in nearshore reproductive habitat of the NWA DPS of loggerhead sea turtles under this Opinion. No other pile-supported structures are allowed in nearshore reproductive habitat under this Opinion.

A2.16. U.S. Caribbean sea turtle critical habitat (hawksbill, leatherback, and the NA DPS of green

sea turtle critical habitat): ATONs (pile-supported and anchored buoys) are allowed near sea turtle nesting beaches under this Opinion. No other pile-supported structures are allowed near sea turtle nesting beaches under this Opinion.

Page 36: REPLY TO ATTENTION OF ATTACHMENT B Documents/Matlacha F… · Fort Myers Permits Section SAJ-1990-40367 (GP-EPL) Ehab Guirguis Lee County Facilities Construction and Management 1500

ATTACHMENT V

Page 37: REPLY TO ATTENTION OF ATTACHMENT B Documents/Matlacha F… · Fort Myers Permits Section SAJ-1990-40367 (GP-EPL) Ehab Guirguis Lee County Facilities Construction and Management 1500

STANDARD MANATEE CONDITIONS FOR IN-WATER WORK 2011

The permittee shall comply with the following conditions intended to protect manatees from direct project effects:

a. All personnel associated with the project shall be instructed about the presence of manatees and manatee speed zones, and the need to avoid collisions with and injury to manatees. The permittee shall advise all construction personnel that there are civil and criminal penalties for harming, harassing, or killing manatees which are protected under the Marine Mammal Protection Act, the Endangered Species Act, and the Florida Manatee Sanctuary Act.

b. All vessels associated with the construction project shall operate at "Idle Speed/No Wake” at all times while in the immediate area and while in water where the draft of the vessel provides less than a four-foot clearance from the bottom. All vessels will follow routes of deep water whenever possible.

c. Siltation or turbidity barriers shall be made of material in which manatees cannot become entangled, shall be properly secured, and shall be regularly monitored to avoid manatee entanglement or entrapment. Barriers must not impede manatee movement.

d. All on-site project personnel are responsible for observing water-related activities for the presence of manatee(s). All in-water operations, including vessels, must be shutdown if a manatee(s) comes within 50 feet of the operation. Activities will not resume until the manatee(s) has moved beyond the 50-foot radius of the project operation, or until 30 minutes elapses if the manatee(s) has not reappeared within 50 feet of the operation. Animals must not be herded away or harassed into leaving.

e. Any collision with or injury to a manatee shall be reported immediately to the Florida Fish and Wildlife Conservation Commission (FWC) Hotline at 1-888-404-3922. Collision and/or injury should also be reported to the U.S. Fish and Wildlife Service in Jacksonville (1-904-731-3336) for north Florida or Vero Beach (1-772-562-3909) for south Florida, and to FWC at [email protected]

f. Temporary signs concerning manatees shall be posted prior to and during all in-water project activities. All signs are to be removed by the permittee upon completion of the project. Temporary signs that have already been approved for this use by the FWC must be used. One sign which reads Caution: Boaters must be posted. A second sign measuring at least 8 ½” by 11" explaining the requirements for “Idle Speed/No Wake” and the shut down of in-water operations must be posted in a location prominently visible to all personnel engaged in water-related activities. These signs can be viewed at MyFWC.com/manatee. Questions concerning these signs can be sent to the email address listed above.

Page 38: REPLY TO ATTENTION OF ATTACHMENT B Documents/Matlacha F… · Fort Myers Permits Section SAJ-1990-40367 (GP-EPL) Ehab Guirguis Lee County Facilities Construction and Management 1500

CAUTION: MANATEE HABITAT

All project vessels

IDLE SPEED / NO WAKE

When a manatee is within 50 feet of work all in-water activities must

SHUT DOWN

Report any collision with or injury to a manatee:

Wildlife Alert: 1-888-404-FWCC (3922)

cell * FWC or #FWC