Regulatory Division West Permits Branch Fort Myers Permits Section SAJ-1990-40367 (GP-EPL) Ehab Guirguis Lee County Facilities Construction and Management 1500 Monroe Street Fort Myers, FL 33901 Dear Mr. Guirguis: Your application for a Department of the Army permit received on 24 October 2019 has been assigned number SAJ-1990-40367. A review of the information and drawings provided shows the proposed work is the replacement of an existing 3020SF dilapidated public fishing pier which has been condemned for public safety. The existing pier will be completely removed and the proposed pier will be placed in the same footprint as the existing. The project will result in the installation of seventy-six 14” square concrete pilings. The project would affect waters of the United States associated within Matlacha Pass and is located in Section 24, Township 44 South, Range 22 East, at 4577 Pine Island Road NW, Lee County, Florida
Your project, as depicted on the enclosed drawings (Attachment I), is authorized by Nationwide Permit (NWP) 3. The authorization of NWP 3 is valid until March 18, 2022.
Please access the Corps' Jacksonville District Regulatory Division Internet page to view the special and general conditions for NWP-3, which apply specifically to these authorizations. The Internet URL address is:
http://www.saj.usace.army.mil/Missions/Regulatory.aspx Please be aware this Internet address is case sensitive; and, you will need to enter it exactly as it appears above. Once there you will need to click on “Source Book”; and, then click on “Nationwide Permits.” Then you will need to click on the specific NWP permits noted above. You must comply with all of the special and general conditions of the permit; and, any project-specific conditions noted below, or you may be subject to enforcement action.
The following special conditions are included with these authorizations and are to ensure compliance with the federal permit and to minimize impacts to the aquatic environment: 1. Reporting Address: The Permittee shall submit all reports, notifications, documentation and correspondence required by the general and special conditions of this permit to either (not both) of the following addresses:
DEPARTMENT OF THE ARMY
JACKSONVILLE DISTRICT CORPS OF ENGINEERS
1520 Royal Palm Square Blvd, Suite 310
Fort Myers, FL 33919
December 5, 2019
REPLY TO
ATTENTION OF
-2-
a. For electronic mail (preferred): [email protected] (not to exceed 15 MB). b. For standard mail: U.S. Army Corps of Engineers, Regulatory Division, Enforcement Section, P.O. Box 4970, Jacksonville, FL 32232-0019. The Permittee shall reference this permit number, SAJ-1990-40367 (NW-EPL), on all submittals. 2. Self-Certification: Within 60 days of completion of the work authorized by this permit, the Permittee shall complete the attached “Self-Certification Statement of Compliance” form and submit it to the Corps (Attachment II). In the event that the completed work deviates in any manner from the authorized work, the Permittee shall describe the deviations between the work authorized by this permit and the work as constructed on the “Self-Certification Statement of Compliance” form. The description of any deviations on the “Self-Certification Statement of Compliance” form does not constitute approval of any deviations by the Corps. 3. Commencement Notification: Within 10 days from the date of initiating the work authorized by this permit the Permittee shall submit a completed “Commencement Notification” Form (Attachment III). 4. Assurance of Navigation and Maintenance: The Permittee understands and agrees that, if future operations by the United States require the removal, relocation, or other alteration, of the structures or work herein authorized, or if in the opinion of the Secretary of the Army or his authorized representative, said structure or work shall cause unreasonable obstruction to the free navigation of the navigable waters, the Permittee will be required, upon due notice from the Corps of Engineers, to remove, relocate, or alter the structural work or obstructions caused thereby, without expense to the United States. No claim shall be made against the United States on account of any such removal or alteration. 5. Jacksonville District Programmatic Biological Opinion (JAXBO), November 2017, Project Design Criteria (PDCs): Structures authorized under this permit must comply with all applicable PDCs, based on the permitted activity, as required by JAXBO. Please note that failure to comply with the applicable PDCs, where a take of listed species occurs, would constitute an unauthorized take, and noncompliance with this permit. The NMFS is the appropriate authority to enforce the terms and conditions of JAXBO. The most current version of
-3-
JAXBO can be accessed at the Jacksonville District Regulatory Division internet webpage in the Endangered Species section of the Sourcebook located at: http://www.saj.usace.army.mil/Missions/Regulatory/SourceBook.aspx Note - JAXBO may be subject to revision at any time. The most recent version
of these conditions must be utilized during the design and construction of the permitted work. In accordance with the Endangered Species Act, and for those projects which do not comply with JAXBO, the Corps will seek individual consultation with the NMFS. Note - some authorized activities may deviate from the PDCs. In cases, where
the activity (i.e., structure dimensions, length, etc.) deviates from the PDCs, the permit drawings shall supersede the PDCs. For each of the following authorized activities subject of this permit, the permittee shall adhere to the following PDCs, which are attached to, and made part of, this authorization/verification letter (Attachment IV): Activity 2 - Pile-supported Structures and Anchored Buoys: (AP.1-14; A2.1-16) 6. Manatee Conditions: The Permittee shall abide by the enclosed standard
construction conditions designed to protect the endangered West Indian manatee, 2011 (Attachment V). 7. Posting of Permit: The Permittee shall have available and maintain for review
a copy of this permit and approved plans at the construction site. 8. Daylight Hours: All activities must be completed during daylight hours. 9. Agency Changes/Approvals: Should any other agency require and/or approve changes to the work authorized or obligated by this permit, the Permittee is advised a modification to this permit instrument is required prior to initiation of those changes. It is the Permittee’s responsibility to request a modification of this permit from the Fort Myers Permits Section. The Corps reserves the right to fully evaluate, amend, and approve or deny the request for modification of this permit. 10. Educational Signs: signs must be posted in a visible location(s), alerting users of listed species in the area susceptible to vessel strikes and hook-and-line captures. The most current version of the signs that must be downloaded and sign installation guidance are available at:
-4-
(http://sero.nmfs.noaa.gov/protected_resources/section_7/protected_species_educational_signs/index.html). The signs required to be posted by area are stated below:
All projects in Florida shall use the Save Sea Turtle, Sawfish, and Dolphin sign. These signs shall include contact information to the sea turtle and marine mammal stranding networks and smalltooth sawfish encounter database. 11. Monofilament Recycling Bins: All commercial and public boat ramps also must install and maintain for the life of the facility monofilament recycling bins to reduce the risk of turtle or sawfish entanglement in or ingestion of marine debris. Monofilament recycling bins must: a. Be constructed and labeled according to the instructions provided at http://mrrp.myfwc.com b. Be maintained for the life of the facility in working order and emptied frequently so that they do not overflow. 12: Turbidity Barriers: Prior to the initiation of any of the work authorized by
this permit, the Permittee shall install floating turbidity barriers with weighted skirts that extend to within 1 foot of the bottom around all work areas that are in, or adjacent to, surface waters. The turbidity barriers shall remain in place and be maintained until the authorized work has been completed and all suspended and erodible materials have been stabilized. Turbidity barriers shall be removed upon stabilization of the work area. 13. Historic Properties:
a. No structure or work shall adversely affect impact or disturb properties listed in the National Register of Historic Places (NRHP) or those eligible for inclusion in the NRHP. b. If during the ground disturbing activities and construction work within the permit area, there are archaeological/cultural materials encountered which were not the subject of a previous cultural resources assessment survey (and which shall include, but not be limited to: pottery, modified shell, flora, fauna, human remains, ceramics, stone tools or metal implements, dugout canoes, evidence of structures or any other physical remains that could be associated with Native American cultures or early colonial or American settlement), the Permittee shall immediately stop all work and ground-disturbing activities within a 100-meter diameter of the discovery and notify the Corps within the same business day (8 hours). The Corps shall then notify the Florida State Historic Preservation Officer
-5-
(SHPO) and the appropriate Tribal Historic Preservation Officer(s) (THPO(s)) to assess the significance of the discovery and devise appropriate actions. c. Additional cultural resources assessments may be required of the permit area in the case of unanticipated discoveries as referenced in accordance with the above Special Condition ; and if deemed necessary by the SHPO, THPO(s), or Corps, in accordance with 36 CFR 800 or 33 CFR 325, Appendix C (5). Based, on the circumstances of the discovery, equity to all parties, and considerations of the public interest, the Corps may modify, suspend or revoke the permit in accordance with 33 CFR Part 325.7. Such activity shall not resume on non-federal lands without written authorization from the SHPO for finds under his or her jurisdiction, and from the Corps. d. In the unlikely event that unmarked human remains are identified on non-federal lands, they will be treated in accordance with Section 872.05 Florida Statutes. All work and ground disturbing activities within a 100-meter diameter of the unmarked human remains shall immediately cease and the Permittee shall immediately notify the medical examiner, Corps, and State Archeologist within the same business day (8-hours). The Corps shall then notify the appropriate SHPO and THPO(s). Based, on the circumstances of the discovery, equity to all parties, and considerations of the public interest, the Corps may modify, suspend or revoke the permit in accordance with 33 CFR Part 325.7. Such activity shall not resume without written authorization from the State Archeologist and from the Corps.
This authorization does not include conditions that would prevent the ‘take’ of a state-listed fish or wildlife species. These species are protected under sec. 379.411, Florida Statutes, and listed under Rule 68A-27, Florida Administrative Code. With regard to fish and wildlife species designated as species of special concern or threatened by the State of Florida, you are responsible for coordinating directly with the Florida Fish and Wildlife Conservation Commission (FWC). You can visit the FWC license and permitting webpage (http://www.myfwc.com/license/wildlife/) for more information, including a list of those fish and wildlife species designated as species of special concern or threatened. The Florida Natural Areas Inventory (http://www.fnai.org/) also maintains updated lists, by county, of documented occurrences of those species.
This authorization does not give absolute Federal authority to perform the work as specified on your application. The proposed work may be subject to local building restrictions mandated by the National Flood Insurance Program. You should contact your local office that issues building permits to determine if your site is located in a flood-prone area, and if you must comply with the local building requirements mandated by the National Flood Insurance Program.
-6-
If you are unable to access the internet or require a hardcopy of any of the conditions, limitations, or expiration date for the above referenced NWP, please contact Eric Larrat by telephone at 239-334-1975. Thank you for your cooperation with our permit program. The Corps’ Jacksonville District Regulatory Division is committed to improving service to our customers. We strive to perform our duty in a friendly and timely manner while working to preserve our environment. We invite you to complete our automated Customer Service Survey at http://corpsmapu.usace.army.mil/cm_apex/f?p=regulatory_survey. Please be aware this Internet address is case sensitive; and, you will need to enter it exactly as it appears above. Your input is appreciated – favorable or otherwise. Sincerely,
Eric P. Larrat Project Manager
Enclosures Attachment I: Project Drawings Attachment II: Self-Certification Statement of Compliance Form Attachment III: Commencement Notification Form Attachment IV: Project Design Criteria (PDCs) for In-Water Activities Attachment V: Manatee In-Water Work Conditions
GENERAL CONDITIONS 33 CFR PART 320-330
1. The time limit for completing the work authorized ends on the dates identified in the letter. 2. You must maintain the activity authorized by this permit in good condition and in conformance with the terms and conditions of this permit. You are not relieved of this requirement if you abandon the permitted activity, although you may make a good faith transfer to a third party in compliance with General Condition 4 below. Should you wish to cease to maintain the authorized activity or should you desire to abandon it without a good faith transfer, you must obtain a modification of this permit from this office, which may require restoration of the area. 3. If you discover any previously unknown historic or archeological remains while accomplishing the activity authorized by this permit, you must immediately notify this office of what you have found. We will initiate the Federal and state coordination required to determine if the remains warrant a recovery effort or if the site is eligible for listing in the National Register of Historic Places. 4. If you sell the property associated with this permit you must obtain the signature of the new owner in the space provided and forward a copy of the permit to this office to validate the transfer of this authorization. 5. If a conditioned water quality certification has been issued for your project, you must comply with the conditions specified in the certification as special conditions to this permit. For your convenience, a copy of the certification is attached if it contains such conditions. 6. You must allow a representative from this office to inspect the authorized activity at any time deemed necessary to ensure that it is being or has been accomplished in accordance with the terms and conditions of your permit.
ATTACHMENT I
TH
E
OF
FI
CI
AL
RE
CO
RD
OF
THI
S
SH
EE
T I
S
TH
E
EL
EC
TR
ONI
C
FI
LE
DI
GI
TA
LL
Y
SI
GN
ED
AN
D
SE
AL
ED
UN
DE
R
RU
LE 61
G15-23.004,
F.
A.
C.
SDS 6/19
CLH 6/19
RMW 6/19
VAZ 6/19REGISTRY NO. 27559
FORT MYERS, FL 33901
SUITE 200
2121 MCGREGOR BOULEVARD
HIGHSPANS ENGINEERING, INC.
P.E. LICENSE NUMBER 60524
VINCENT ZALIAUSKAS, P.E.
40
Feet
0 10
REF. DWG. NO.
SHEET NO.
SHEET TITLE:
PROJECT NAME:
DRAWN BY:
CHECKED BY:
DESIGNED BY:
CHECKED BY:
ROAD NO. COUNTY PROJECT NO.
REVISIONS
DATE BY DESCRIPTION DATE BY DESCRIPTION
LEE
Sabrina 10/11/2019 12:32:25 PM H:\_Project18\1812_MatlachaPier\struct\AERIAL_11x17.DGN
CONSTRUCTION & MANAGEMENT
LEE COUNTY FACILITIES
AERIAL VIEW
73'-2"
23'-7"
39'-7"
10'-0"
SIDEWALK
CONCRETE
LEGEND
MANGROVE FRINGE
OPEN WATER
SAND & MUD
SAND & MUD
APPROXIMATE MHW = 1.14'
UPLANDS
UPLANDS
COVERAGE 5-10%
(Halodule wrightii)Shoalgrass
APPROXIMATE MEAN HIGH WATER (MHW)
MANGROVE FRINGE
& GRAVITY WALL
27'-6" RAMP
16'-0"183'-6"
(TOTAL PILES = 76)
14" SQ. CONCRETE PILES (TYP.)
TOTAL AREA = 103.4 SF
NO. PILES = 76
AREA 14" SQ. PILES = 1.36 SF
PROPOSED CONCRETE PILES:
TOTAL AREA = 44.0 SF
NO. PILES = 80
AREA 10" DIA. PILES = 0.55 SF
EXISTING TIMBER PILES:
TOTAL PROJECT AREA = 3020 SF
MATLACHA FISHING PIER REPLACEMENT
25
36
PINELAND
Demere Ldg.
Underhill
Pt.
Thirsting
Lake
Tom Black
Lake
Buzzard
Bay
Demere Ldg.
Underhill
Pt.
Cr.
Rock
Cr.
Pine
Cr.
Island
Underhill
Cr.
TRANQUILITY BAY
AIRPORT
(PVT)
Chiquita
Boulevard
Cape
Maria Dr.
Burnt
McCARDLE IS.
INDIAN
FIELD
PUMPKIN
KEY
LITTLE
PINE
ISLAND
WEST
IS.
PORPOISE
POINT IS.
BEAR
KEY
DEER
KEY
LANIER KEY
BEN
COLEMAN
KEYS
DEER
STOP
KEYS
P I
N
E
MATLACHA
Lower 36
Bay
Upper 36
Bay
Pontoon
Bay
Pass
Matlacha
MATLACHA
PASS
AQUATIC
PRESERVE
Hole
Mud
The
234
9 11
21 22 23
26272829
32 3334
35
3
9
10
1516
WP
S
B
PINELAND
765
78
78
CP
78
8 9
1617
7
18
282930
3132
33
456
8 97
12
13
20 2119
R-2
3-E
R-2
2-E
R-2
3-E
R-2
2-E
TH
E
OF
FI
CI
AL
RE
CO
RD
OF
THI
S
SH
EE
T I
S
TH
E
EL
EC
TR
ONI
C
FI
LE
DI
GI
TA
LL
Y
SI
GN
ED
AN
D
SE
AL
ED
UN
DE
R
RU
LE 61
G15-23.004,
F.
A.
C.
T-44-S
T-45-S
T-44-S
T-45-S
CHARLOTTE COUNTY
ON ANY ELECTRONIC COPIES.
AND THE SIGNATURE MUST BE VERIFIED
NOT CONSIDERED SIGNED AND SEALED
PRINTED COPIES OF THIS DOCUMENT ARE
ON THE DATE ADJACENT TO THE SEAL
SIGNED AND SEALED BY
THIS ITEM HAS BEEN DIGITALLY
STATE OF
� � �
No 60524
SA
K
SUAILAZ TNEC
NIV
RE
ENI
GNE LANOISS
E
FO
RP
ADIROL
F
ESNECIL
SHEET DESCRIPTION
EXPRESSWAY
TU
RNPIK
E
10
PENSACOLA FORT WALTON
BEACH
PANAMACITY
CHIPLEY
TALLAHASSEE
75
10
295
95
JACKSONVILLE
ST AUGUSTINE
GAINESVILLE
OCALA DAYTONA BEACH
DELAND4
NEW PORT RICHEY
TAMPA
754
LAKELAND
MELBOURNE -COCOA
ORLANDO
BARTOWST PETERSBURG
275
SARASOTA -
BRADENTON
75
95
FT PIERCE
FT MYERS
WEST PALM
BEACH
FT LAUDERDALE
MIAMI
75
75
NAPLES
KEY WEST
CITY
LAKE
FLO
RID
A'S
BEACH LINE
NO.
SHEET
YEAR
FISCAL
12:26:59 PM H:\_Project18\1812_MatlachaPier\struct\KeySheet01.dgnSabrina 10/11/2019
STRUCTURE PLANS
http://www.dot.state.fl.us/programmanagement/Implemented/SpecBooks
for Road and Bridge Construction at the following website:
Florida Department of Transportation, January 2019 Standard Specifications
http://www.dot.state.fl.us/rddesign/DesignStandards/Standards.shtm
and applicable Design Standards Revisions (DSRs) at the following website:
Florida Department of Transportation, FY 2018-19 Design Standards eBook (DSeB)
LEE COUNTY
CONTRACT PLANS
SHEET NO.
ELAINE CAPPS, P.E.
CONTRACT NO.
CONSTRUCTION
1
LEE COUNTY PROJECT MANAGER:
FACILITIES CONSTRUCTION & MANAGEMENT
MATLACHA FISHING PIER REPLACEMENT
STANDARD PLANS FOR ROAD AND BRIDGE CONSTRUCTION
REGISTRY NO. 27559
FORT MYERS, FL 33901
SUITE 200
2121 MCGREGOR BLVD.
HIGHSPANS ENGINEERING, INC.
P.E. LICENSE NUMBER 60524
VINCENT ZALIAUSKAS, P.E.
LOCATION OF PROJECT
LOCATION OF PROJECT
GOVERNING DESIGN STANDARDS:
GOVERNING STANDARD SPECIFICATIONS:
INDEX OF STRUCTURE PLANS
ENGINEER OF RECORD:
STRUCTURE PLANS
18
515-062
515-061
400-011
PEDESTRIAN/BICYCLE RAILING (ALUMINUM)
BRIDGE PEDESTRIAN/BICYCLE RAILING (ALUMINUM)
GRAVITY WALL
REINFORCING BAR LIST
PIER DETAILS
CLEANING STATION DETAILS
PILE CAP DETAILS
TYPICAL SECTIONS
PLAN & ELEVATION
EXISTING CONDITIONS
GENERAL NOTES
KEY SHEET
15
14
13
11 - 12
8 - 10
5 - 7
4
2 - 3
1
TH
E
OF
FI
CI
AL
RE
CO
RD
OF
THI
S
SH
EE
T I
S
TH
E
EL
EC
TR
ONI
C
FI
LE
DI
GI
TA
LL
Y
SI
GN
ED
AN
D
SE
AL
ED
UN
DE
R
RU
LE 61
G15-23.004,
F.
A.
C.
SDS 6/19
CLH 6/19
RMW 6/19
VAZ 6/19REGISTRY NO. 27559
FORT MYERS, FL 33901
SUITE 200
2121 MCGREGOR BOULEVARD
HIGHSPANS ENGINEERING, INC.
P.E. LICENSE NUMBER 60524
VINCENT ZALIAUSKAS, P.E. REF. DWG. NO.
SHEET NO.
SHEET TITLE:
PROJECT NAME:
DRAWN BY:
CHECKED BY:
DESIGNED BY:
CHECKED BY:
ROAD NO. COUNTY PROJECT NO.
REVISIONS
DATE BY DESCRIPTION DATE BY DESCRIPTION
LEE
Sabrina 10/11/2019 12:27:00 PM H:\_Project18\1812_MatlachaPier\struct\GeneralNotes01.dgn
CONSTRUCTION & MANAGEMENT
LEE COUNTY FACILITIES
GENERAL NOTES
CONCRETE CLASSCOMPRESSIVE STRENGTH (PSI)
MIN. 28-DAY
IN STRUCTURE
LOCATION OF CONCRETE
5500
3"
2
PRESTRESSED PILING
IS NOTED TO FACE OF CONCRETE.
OF REINFORCING STEEL ARE TO CENTERLINE OF BAR EXCEPT WHERE CLEAR DIMENSION
SECTION 415 FOR ALLOWABLE TOLERANCES. ALL DIMENSIONS PERTAINING TO THE LOCATION
FABRICATION TOLERANCES UNLESS SHOWN AS "MINIMUM COVER". SEE SPECIFICATIONS
CONCRETE COVER DIMENSIONS SHOWN IN THE PLANS DO NOT INCLUDE PLACEMENT AND
PRESTRESSED CONCRETE PILES6000
SUBSTRUCTURE
GENERAL CONSTRUCTION NOTES
CAST-IN-PLACE SUBSTRUCTURE 4"
V (SPECIAL) (W/ SILICA FUME & CALCIUM NITRITE)
IV (W/ SILICA FUME & CALCIUM NITRITE)
CONTRACT DOCUMENTS.
HEREIN, AND JANUARY 2019 STANDARD SPECIFICATIONS FOR ROAD AND BRIDGE CONSTRUCTION, AS AMENDED BY
FLORIDA DEPARTMENT OF TRANSPORTATION, 2019-20 STANDARD PLANS AND REVISED INDEX DRAWINGS AS APPENDED
B. GOVERNING STANDARDS AND CONSTRUCTION SPECIFICATIONS
VERTICAL DATUM USED IS NATIONAL GEODETIC VERTICAL DATUM OF 1929 (NGVD 29), UNLESS OTHERWISE NOTED.
C. VERTICAL DATUM
LOAD AND RESISTANCE FACTOR DESIGN (LRFD) METHOD USING STRENGTH AND SERVICE.
E. DESIGN METHODOLOGY
3. UTILITIES: NO ALLOWANCE FOR UTILITY LOADS HAS BEEN INCLUDED IN THE DESIGN.
PRESSURE TREATED WOOD: 41 PCF
REINFORCED CONCRETE: 150 PCF
2. DEAD LOADS:
WAVE LOAD: 1.088 KIPS APPLIED AT STILL WATER LEVEL
FBC PEDESTRIAN LOAD FOR RAILING: 200 LB + 50 PLF
PEDESTRIAN LIVE LOAD: 100 PSF
1. LIVE LOADS:
F. DESIGN LOADINGS
5. AMERICAN WOOD COUNCIL NATIONAL DESIGN SPECIFICATIONS FOR WOOD CONSTRUCTION, 2012.
4. FDOT DESIGN MANUAL DATED JANUARY, 2019 AND SUBSEQUENT ROADWAY DESIGN BULLETINS.
FACTOR (LRFD) BRIDGE DESIGN SPECIFICATIONS, 8TH EDITION AND ALL SUBSEQUENT INTERIMS.
3. AMERICAN ASSOCIATION OF STATE HIGHWAY AND TRANSPORTATION OFFICIALS (AASHTO) LOAD AND RESISTANCE
2. FDOT STRUCTURES MANUAL DATED JANUARY 2019 AND SUBSEQUENT STRUCTURES DESIGN BULLETINS.
1. FLORIDA BUILDING CODE, CURRENT EDITION
A. DESIGN SPECIFICATIONS
GENERAL NOTES (1 OF 2)
ALL COMPONENTS DESIGNED FOR EXTREMELY AGGRESSIVE ENVIRONMENT.
D. ENVIRONMENT
CLASS 1 OR CLASS 2, BARE CONCRETE WITH BUG HOLES FILLED AND RUBBED.
H. CONCRETE FINISH COATINGCONSTRUCTION WORK HOURS SHALL BE FROM 8:00AM TO 7:00PM SEVEN DAYS A WEEK.16.
ORIGINAL CONDITION AT THE CONTRACTOR’S EXPENSE.ANY PUBLIC OR PRIVATE PROPERTY DAMAGED BY THE CONTRACTOR OR ANY SUB-CONTRACTOR SHALL BE RESTORED TO15.
SUNLIGHT FOR MORE THAN TWO WEEKS. ANCHORING LOCATIONS SHALL BE APPROVED BY THE PROJECT ENGINEER.
ANCHORING BARGES AND OTHER STRUCTURES). THE CONTRACTOR SHALL NOT SHADE ANY BENTHIC COMMUNITY FROM DIRECT
CONTACT WITH THE SEABED IN THESE AREAS AND ANY DISTURBANCE OF BOTTOM SEDIMENT (E.G. FROM MOVING OR
SEAGRASS BEDS AND OTHER BENTHIC COMMUNITIES EXIST IN THE PROJECT AREA. THE CONTRACTOR SHALL PREVENT14.
PROJECT ENGINEER WITHIN 24 HOURS OF EACH ENCOUNTER.
LISTED SPECIES OF SPECIAL CONCERN. SHOULD THESE SPECIES BE ENCOUNTERED, THE CONTRACTOR SHALL CONTACT THE
COMPLY WITH ALL FEDERAL AND STATE REQUIREMENTS REGARDING ENDANGERED AND THREATENED SPECIES AND STATE
AREA: WEST INDIAN MANATEE, SMALLTOOTH SAWFISH, MARINE TURTLES, AND AMERICAN CROCODILE. THE CONTRACTOR SHALL
THE FOLLOWING FEDERALLY AND STATE LISTED ANIMAL SPECIES COULD INHABIT OR MIGRATE THROUGH THE CONSTRUCTION13.
CONSTRUCTION TO AVOID TURBID RUNOFF.
THE CONTRACTOR SHALL MAINTAIN CURRENT WATER QUALITY CONDITIONS AND PROVIDE TURBIDITY BARRIERS DURING12.
CONTROL DEVICES.
ANY MATERIAL TO BE STOCKPILED FOR PERIODS GREATER THAN 24 HOURS SHALL BE PROTECTED BY APPROPRIATE EROSION11.
DEVICES INCLUDING MONITORING, REPORTING AND MAINTENANCE.
THE CONTRACTOR SHALL PROVIDE AN EROSION, SEDIMENTATION, AND POLLUTION PREVENTION PLAN, AND PROVIDE CONTROL10.
DISCHARGE OF ANY FOREIGN MATERIAL INTO THE WATER SHOULD BE PERMITTED.
THIS PROJECT IS LOCATED IN THE MATLACHA PASS AQUATIC PRESERVE. NO DEGRADATION OF WATER QUALITY, AND/OR THE9.
THE CONTRACTOR SHALL ACQUIRE AND MAINTAIN ALL FEDERAL, STATE, AND LOCAL PERMITS REQUIRED FOR CONSTRUCTION.8.
ISSUED OCTOBER 3, 2003: MHW=+1.14 FT, HIGH WATER = +1.43', LOW WATER = 0.0' FT USING NGVD29.
TIDAL ELEVATIONS WERE OBTAINED FROM DEPARTMENT OF ENVIRONMENTAL PROTECTION (DEP) PERMIT NO. 36-0213088-001,7.
PLAN APPROVED BY THE USCG.
RESTRICTING HORIZONTAL AND/OR VERTICAL CLEARANCES THE CONTRACTOR SHALL SUBMIT TO THE COUNTY A CONSTRUCTION
ADDRESS: [email protected], TELEPHONE NUMBER (305) 415-6946. IN ADVANCE OF ANY CONSTRUCTION ACTIVITY
TO NAVIGATION SHALL BE COORDINATED WITH THE UNITED STATES COAST GUARD (USCG), MR. EDDIE LAWRENCE. EMAIL
IN A TIMELY MANNER TO ALLOW BOATS AND OTHER VESSELS TO REASONABLY NAVIGATE THROUGH. ANY SHORT TERM IMPACTS
THE CONTRACTOR IS RESPONSIBLE FOR MAINTAINING NAVIGABLE WATERWAYS. THE CONTRACTOR SHALL MOVE EQUIPMENT6.
PARKING SPACES AND GREEN SPACE FOR STAGING AREA.
STAGING AREAS WITH THE PROJECT ENGINEER AT LEAST SEVENTY-TWO (72) HOURS PRIOR TO USE. CONTRACTOR CAN UTILIZE
ENVIRONMENTALLY SENSITIVE AREAS. THE CONTRACTOR SHALL REVIEW ENVIRONMENTAL REQUIREMENTS OF ANY PROPOSED
NO STAGING OR OTHER ACTIVITIES FOR THIS PROJECT WILL BE ALLOWED WITHIN OR ADJACENT TO THE WATERWAY OR OTHER5.
UTILITIES MUST BE ADJUSTED AT THE CONTRACTORS EXPENSE.
THE CONTRACTOR IS RESPONSIBLE FOR RESOLVING ANY UTILITY CONFLICTS BEFORE CONSTRUCTION BEGINS. ALL CONFLICTING4.
CONSTRUCTION AND NOTIFY THE ENGINEER OF ANY DISCREPANCIES.
IT IS THE CONTRACTOR'S RESPONSIBILITY TO VERIFY INFORMATION AND DATA IN THE PLANS BEFORE BEGINNING3.
REPAIRED AT THE CONTRACTOR'S EXPENSE.
IN THE AREA OF THE PROJECT PRIOR TO BEGINNING CONSTRUCTION ACTIVITIES. DAMAGE TO EXISTING UTILITIES SHALL BE
PRIOR TO BEGINNING CONSTRUCTION ACTIVITIES. THE CONTRACTOR SHALL NOTIFY ALL UTILITY COMPANIES WITH FACILITIES
IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO DETERMINE THE EXACT LOCATION AND OWNERSHIP OF ALL UTILITIES2.
SECTIONS TO ENSURE THAT THE CHANNEL WIDTH/DEPTH HAS NOT BEEN DECREASED.
DIRECTION OF A FLORIDA PROFESSIONAL SURVEYOR AND MAPPER (PSM). THE SURVEY IS TO INCLUDE PROFILE AND CROSS
IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO PERFORM A PRE- AND POST-CONSTRUCTION SURVEY UNDER THE1.
3. CONCRETE COVER:
2. CONCRETE CLASS:
1. REINFORCING STEEL: ALL REINFORCING STEEL SHALL BE ASTM A615 GRADE 60
G. MATERIALS
BULB: AMBER LED LIGHT BULB PART #: PAR38 MADE BY SYNERGY LIGHTING INC., OR APPROVED EQUAL.3.
LUMINAIRE: LIGHT FIXTURE PT40 PART#: 610012 MADE BY LIGHT INC., OR APPROVED EQUAL.2.
POLE: 12'-0" ALUMINUM POLE, PART#: H12A4RS125 MADE BY ENERGY LIGHT INC., OR APPROVED EQUAL.1.
L. LIGHTING
JOINTS OR ALTERATIONS TO THOSE SHOWN SHALL REQUIRE APPROVAL OF THE ENGINEER.
CONSTRUCTION JOINTS WILL BE PERMITTED ONLY AT THE LOCATIONS INDICATED IN THE PLANS. ADDITIONAL CONSTRUCTION
K. JOINTS IN CONCRETE
ALL ELECTRICAL WORK IS TO BE PERFORMED BY A LICENSED ELECTRICIAN.3.
CONTRACTOR IS TO FIELD LOCATE EXISTING UTILITIES.2.
LOCATIONS OF EXISTING UTILITIES SHOWN IN THE PLANS ARE APPROXIMATE.1.
J. UTILITIES
ALL DIMENSIONS IN THESE PLANS ARE MEASURED IN FEET EITHER HORIZONTALLY OR VERTICALLY UNLESS OTHERWISE NOTED.
I. PLAN DIMENSIONS
12. FLORIDA FISH AND WILDLIFE CONSERVATION COMMISSION MONOFILAMENT RECOVERY AND RECYCLE BIN.
APPROVED EQUAL.
11. HIGHLAND PRODUCTS GROUP, LLC 6' LONG, SURFACE MOUNTED TRAILSIDE RECYCLED PLASTIC BENCH, OR
" THICK CUSTOM CLEANING STATION TABLE, OR APPROVED EQUAL.43BOAT OUTFITTERS 4'-0"x2'-6"x10.
GIBSON STAINLESS & SPECIALTY INC. 2" STAINLESS STEEL CONDUIT TWO HOLE STRAP, OR APPROVED EQUAL.9.
GIBSON STAINLESS & SPECIALTY INC. 2" STAINLESS STEEL CONDUIT HANGERS, OR APPROVED EQUAL.8.
ALL HARDWARE IS STAINLESS STEEL 316, UNLESS NOTED OTHERWISE.a.
STEEL FASTENERS AND HARDWARE7.
THE WIDTH OF THE PIER TO ENSURE DECKING HAS A FIRM CONTACT WITH ALL STRINGERS.
" TO PROVIDE A FLAT SURFACE ACROSS83VARIATION IN DEPTH BETWEEN STRINGERS SHALL NOT EXCEED c.
BORING WITH PRESERVATIVE TREATMENT USED FOR PILES OR TIMBER.
DEPRESSIONS OR OPENINGS AROUND BOLT HOLES, JOINTS, OR GAPS INCLUDING RECESSES FORMED BY COUNTER
TIMBERS IN ACCORDANCE WITH AWPA; TRIM CUTS AND ABRASIONS BEFORE FIELD TREATMENT; PAINT
FIELD TREAT CUTS, BEVELS, NOTCHES, REFACING AND ABRASIONS MADE IN THE FIELD IN TREATED PILES ORb.
PRESSURE TREATED SOUTHERN YELLOW PINE #2 S4S 0.40 ACQa.
WOOD STRINGERS AND BLOCKING6.
" MAX. GAP BETWEEN DECK BOARDS.21PROVIDE b.
TANDECK ULTIMATE MARINE DOCK BOARD, OR APPROVED EQUAL.a.
WOOD DECKING AND HANDRAILS5.
LOAD STABILITY.
PILES DRIVEN TO CUTOFF ELEVATION WILL MEET THE MINIUMUM 2:1 EMBEDMENT REQUIRED FOR LATERALc.
T-HEAD PILE LENGTHS: 25 FTb.
MAIN PIER PILE LENGTHS: 20 FTa.
CONCRETE PILES4.
MATLACHA FISHING PIER REPLACEMENT
TH
E
OF
FI
CI
AL
RE
CO
RD
OF
THI
S
SH
EE
T I
S
TH
E
EL
EC
TR
ONI
C
FI
LE
DI
GI
TA
LL
Y
SI
GN
ED
AN
D
SE
AL
ED
UN
DE
R
RU
LE 61
G15-23.004,
F.
A.
C.
SDS 6/19
CLH 6/19
RMW 6/19
VAZ 6/19REGISTRY NO. 27559
FORT MYERS, FL 33901
SUITE 200
2121 MCGREGOR BOULEVARD
HIGHSPANS ENGINEERING, INC.
P.E. LICENSE NUMBER 60524
VINCENT ZALIAUSKAS, P.E. REF. DWG. NO.
SHEET NO.
SHEET TITLE:
PROJECT NAME:
DRAWN BY:
CHECKED BY:
DESIGNED BY:
CHECKED BY:
ROAD NO. COUNTY PROJECT NO.
REVISIONS
DATE BY DESCRIPTION DATE BY DESCRIPTION
LEE
Sabrina 10/11/2019 12:27:01 PM H:\_Project18\1812_MatlachaPier\struct\GeneralNotes01.dgn
CONSTRUCTION & MANAGEMENT
LEE COUNTY FACILITIES
NOISE BEST MANAGEMENT PRACTICES (BMPS) FOR PILING INSTALLATION
BALLAST TO COUNTERACT THE BUOYANCY OF THE AERATION PIPES IN OPERATION.
FACILITATES TRANSPORT AND PLACEMENT OF THE SYSTEM, KEEPS THE AERATION PIPES STABLE, AND PROVIDES
THE AIR, DISTRIBUTION MANIFOLDS OR HEADERS, PERFORATED AERATION PIPE, AND A FRAME. THE FRAME
GENERAL - AN UNCONFINED BUBBLE CURTAIN IS COMPOSED OF AN AIR COMPRESSOR(S), SUPPLY LINES TO DELIVERA.
DISTRIBUTE SMALL AIR BUBBLES AROUND 100% OF THE PILE PERIMETER FOR THE FULL DEPTH OF THE WATER COLUMN.
INSTALLATION PERIOD, SURROUND THE PILE BEING DRIVEN BY A CONFINED OR UNCONFINED BUBBLE CURTAIN THAT WILL
IF WATER VELOCITY IS EQUAL TO OR LESS THAN 1.6 ft PER SECOND (1.1 MILES PER HOUR) FOR THE ENTIRE1.
METHODS:
WHEN USING AN IMPACT HAMMER TO DRIVE OR PROOF CONCRETE PILES, USE ONE OF THE FOLLOWING SOUND ATTENUATION
BUBBLE CURTAIN SPECIFICATIONS FOR PILE DRIVING
INSTALLED BY VIBRATORY HAMMER INSTEAD, FOLLOWING BMP PLAN A).
A DIFFERENT METHOD USING THE APPROPRIATE NOISE BMPS DEFINED IN THIS DOCUMENT. (E.G., CONCRETE PILES MAY BE
IF THE REQUIRED NOISE ABATEMENT MEASURE DISCUSSED ABOVE CANNOT BE USED, THEN THE PILE MUST BE INSTALLED BY
CONTROL METHOD MUST RECEIVE PRIOR APPROVAL BY NMFS AND THE USACE.
BELOW, AND BE FOLLOWED AS DETAILED IN THE USACE PERMIT APPLICATION. THE USE OF ANY OTHER ALTERNATIVE NOISE
BUBBLE CURTAIN DESIGN MUST ADHERE TO THE GUIDELINES FOR UNCONFINED AND CONFINED BUBBLE CURTAINS DEFINED
BEING DRIVEN, AND EXTEND AT LEAST 3 ft ABOVE THE SURFACE OF THE WATER.
BETWEEN THE WALLS. THE TNAP MUST BE LONG ENOUGH TO BE SEATED FIRMLY ON THE SEA BOTTOM, FIT OVER THE PILE
LEAST A 5-in WIDE HOLLOW SPACE COMPLETELY FILLED WITH CLOSED-CELL FOAM OR OTHER NOISE DAMPENING MATERIAL
TNAP DESIGN MUST BE CONSTRUCTED OF A DOUBLE-WALLED TUBULAR CASING (A CASING WITHIN A LARGER CASING), WITH AT
BUBBLE CURTAINS.
NOISE ABATEMENT MEASURES: APPROVED NOISE ABATEMENT MEASURES INCLUDE NOISE ATTENUATION PILES (TNAP) AND/OR
REQUIRED FOR ALL OF THE CONCRETE PILES INSTALLED THAT DAY WITH A MAXIMUM OF 10 PILES INSTALLED PER DAY.
IF MORE THAN 5 PILES WILL BE INSTALLED PER DAY IN A CONFINED SPACE, NOISE ABATEMENT MEASURES (BELOW) ARE4.
BE INSTALLED PER DAY.
IF THE PROJECT IS LOCATED IN A CONFINED SPACE, UP TO 5 CONCRETE PILES MEASURING UP TO 24-in DIAMETER MAY3.
INSTALLED PER DAY.
IF THE PROJECT IS LOCATED IN OPEN WATER, UP TO 10 CONCRETE PILES MEASURING UP TO 24-in DIAMETER MAY BE2.
OR SIGNIFICANTLY REFLECT NOISE.
INCLUDE OBJECTS SUCH AS DOCKS OR OTHER PILE-SUPPORTED STRUCTURES THAT WOULD NOT STOP ANIMAL MOVEMENT
SERVE AS A BARRIER OR OTHERWISE PREVENT ANIMALS FROM MOVING PAST IT TO EXIT THE AREA. THIS DOES NOT
SEAWALL, JETTY) OR STRUCTURE WITHIN 150 FEET (ft) OF THE PILE INSTALLATION SITE THAT WOULD EFFECTIVELY
SOURCE TO ESCAPE IT. A CONFINED SPACE IS DEFINED AS ANY AREA THAT HAS A SOLID OBJECT (E.G., SHORELINE,
IMPORTANT BECAUSE IF A PROJECT OCCURS IN A CONFINED SPACE, AN ANIMAL MAY NOT MOVE THROUGH OR PAST A NOISE
IT MUST BE DETERMINED IF THE PROJECT OCCURS IN OPEN WATER OR A CONFINED SPACE. THIS DIFFERENTIATION IS1.
BELOW:
THE PERMITTEE SHALL FOLLOW ALL CONDITIONS DEFINED IN THE NOISE BMP PLAN A ABOVE PLUS THE CONDITIONS PROVIDED
NOISE BMP PLAN B (FOR IMPACT PILE-DRIVING INSTALLATION OF 6 OR MORE CONCRETE PILES PER DAY)
ALL WORK MUST OCCUR DURING DAYLIGHT HOURS.F.
STRANDING/RESCUE ORGANIZATION.
SERVICE’S PROTECTED RESOURCES DIVISION (727-824-5312) AND THE LOCAL AUTHORIZED SEA TURTLEANY INJURY TO A PROTECTED SPECIES SHALL BE REPORTED IMMEDIATELY TO THE NATIONAL MARINE FISHERIESE.
PROTECTED SPECIES HAS DEPARTED THE PROJECT AREA OF ITS OWN VOLITION.
PROTECTED SPECIES IS SEEN WITHIN A 50-ft RADIUS OF THE EQUIPMENT. ACTIVITIES MAY NOT RESUME UNTIL THE
PROTECTED SPECIES. OPERATION OF ANY MECHANICAL CONSTRUCTION EQUIPMENT SHALL CEASE IMMEDIATELY IF A
PRECAUTIONS SHALL INCLUDE CESSATION OF OPERATION OF ANY MOVING EQUIPMENT CLOSER THAN 50 ft OF A
VESSEL MOVEMENT, ALL APPROPRIATE PRECAUTIONS SHALL BE IMPLEMENTED TO ENSURE ITS PROTECTION. THESE
IF A PROTECTED SPECIES IS SEEN WITHIN 100 yd OF THE ACTIVE DAILY CONSTRUCTION/DREDGING OPERATION ORD.
THE NATIONAL MARINE FISHERIES SERVICE’S PROTECTED RESOURCES DIVISION, ST. PETERSBURG, FLORIDA.BLOCK PROTECTED SPECIES ENTRY TO OR EXIT FROM DESIGNATED CRITICAL HABITAT WITHOUT PRIOR AGREEMENT FROM
PROPERLY SECURED, AND BE REGULARLY MONITORED TO AVOID PROTECTED SPECIES’ ENTRAPMENT. BARRIERS MAY NOTSILTATION BARRIERS SHALL BE MADE OF MATERIAL IN WHICH PROTECTED SPECIES CANNOT BECOME ENTANGLED, BEC.
HARMING, HARASSING, OR KILLING SPECIES PROTECTED UNDER THE ENDANGERED SPECIES ACT OF 1973.
THE PERMITTEE SHALL ADVISE ALL CONSTRUCTION PERSONNEL THAT THERE ARE CIVIL AND CRIMINAL PENALTIES FORB.
PRESENCE OF THESE SPECIES.
ALL CONSTRUCTION PERSONNEL ARE RESPONSIBLE FOR OBSERVING WATER-RELATED ACTIVITIES TO DETECT THEA.
THE PERMITTEE SHALL COMPLY WITH THE FOLLOWING PROTECTED SPECIES CONSTRUCTION CONDITIONS:
NOISE BMP PLAN A (FOR ALL PROJECTS): SEA TURTLE, SMALLTOOTH SAWFISH, AND STURGEON CONSTRUCTION CONDITIONS.
DOCK AND SEAWALL CONSTRUCTION ACTIVITIES.
SAWFISH, AND STURGEON TO POTENTIAL HARMFUL DAILY NOISE EXPOSURE LEVELS ASSOCIATED WITH PILE DRIVING DURING
THE FOLLOWING BEST MANAGEMENT PRACTICES ARE DESIGNED TO REDUCE THE EXPOSURE TO SEA TURTLES, SMALLTOOTH
2
NO. OF LAYERSWATER DEPTH (m)
0 TO LESS THAN 5
4
7
10
13
5 TO LESS THAN 10
10 TO LESS THAN 15
15 TO LESS THAN 20
20 TO LESS THAN 25
EITHER LAMINAR FLOW OR NON-LAMINAR FLOW.
FLOW METERS SHALL BE INSTALLED ACCORDING TO THE MANUFACTURER’S RECOMMENDATION BASED ONIII.
CAN BE ELIMINATED.
CONTINUOUS FROM THE COMPRESSOR TO THE AERATION PIPE INLET, THE FLOW METER AT THE COMPRESSOR
AERATION PIPELINES AT EACH INLET. IN APPLICATIONS WHERE THE FEED LINE FROM THE COMPRESSOR IS
FLOW METERS SHALL BE INSTALLED IN THE MAIN LINE AT EACH COMPRESSOR AND AT EACH BRANCH OF THEII.
PRESSURE IN EACH BRANCH OF THE AERATION PIPELINE.
PRESSURE METERS SHALL BE INSTALLED AT ALL INLETS TO AERATION PIPELINES AND AT POINTS OF LOWEST
FLOW METERS SHALL BE PROVIDED AS FOLLOWS:H.
Vt = 21.53 ft�/min/ft * CIRCUMFERENCE OF THE AERATION RING IN ftOR
Vt = 2.0 m�/min/m * CIRCUMFERENCE OF THE AERATION RING IN mOF THE BUBBLE FLUX AND THE CIRCUMFERENCE OF THE RING:
(21.53 ft³ PER MINUTE PER LIN FT OF PIPE IN EACH LAYER). THE TOTAL VOLUME OF AIR PER LAYER IS THE PRODUCT
THE SYSTEM SHALL PROVIDE A BUBBLE FLUX OF 2.0 m³ PER MINUTE PER LINEAR METER OF PIPE IN EACH LAYERG.
UNIFORM BUBBLE FLUX.
AIR HOLES WITH THIS SIZE AND SPACING SHALL BE PLACED IN 4 ADJACENT ROWS ALONG THE PIPE TO PROVIDE
AIR HOLES SHALL BE 1.6 mm (1/16-in) IN DIAMETER AND SHALL BE SPACED APPROXIMATELY 20 mm (3/4 in) APART.F.
SUBSTRATE WITHOUT SINKING INTO THE SUBSTRATE AND SHALL ACCOMMODATE FOR SLOPED CONDITIONS.
THE LOWEST LAYER OF PERFORATED AERATION PIPE SHALL BE DESIGNED TO ENSURE CONTACT WITH THEE.
AND THE OTHER AT MID-DEPTH.
IN-WATERS GREATER THAN 15 m DEEP, THE SYSTEM SHALL HAVE AT LEAST 2 RINGS: 1 AT THE SUBSTRATE LEVEL
IN-WATER LESS THAN 15 m DEEP, THE SYSTEM SHALL HAVE A SINGLE AERATION RING AT THE SUBSTRATE LEVEL.D.
INTO THE WATER COLUMN (E.G., RUBBER SPACERS, AIR-FILLED CUSHIONS).
COMING INTO CONTACT WITH EACH OTHER AND DO NOT TRANSMIT VIBRATIONS TO THE CONFINEMENT SLEEVE AND
THE CONFINEMENT SHALL CONTAIN RESILIENT PILE GUIDES THAT PREVENT THE PILE AND THE CONFINEMENT FROMC.
TOP OF THE CONFINEMENT SYSTEM).
THE BUBBLE CURTAIN DOES NOT ACT AS A WATER PUMP (I.E., LITTLE OR NO WATER SHOULD BE PUMPED OUT OF THE
LEVEL EXPECTED DURING PILE INSTALLATION SUCH THAT WHEN THE AIR DELIVERY SYSTEM IS ADJUSTED PROPERLY,
THE CONFINEMENT SHALL EXTEND FROM THE SUBSTRATE TO A SUFFICIENT ELEVATION ABOVE THE MAXIMUM WATERB.
BUBBLES.
AIR, DISTRIBUTION MANIFOLDS OR HEADERS, PERFORATED AERATION PIPE(S), AND A MEANS OF CONFINING THE
GENERAL - A CONFINED BUBBLE CURTAIN IS COMPOSED OF AN AIR COMPRESSOR(S), SUPPLY LINES TO DELIVER THEA.
SPECIFICATIONS BELOW.
AIR BUBBLES AROUND 100% OF THE PILE PERIMETER FOR THE FULL DEPTH OF THE WATER COLUMN, ACCORDING TO
BUBBLE RING SURROUNDED BY A FABRIC OR NON-METALLIC SLEEVE). THE CONFINED BUBBLE CURTAIN WILL DISTRIBUTE
OR IF CONSTRUCTING A SEAWALL, SURROUND THE PILE OR AREA BEING DRIVEN BY A CONFINED BUBBLE CURTAIN (E.G., A
IF WATER VELOCITY IS GREATER THAN 1.6 ft PER SECOND (1.1 MILES PER HOUR) AT ANY POINT DURING INSTALLATION2.
EITHER LAMINAR FLOW OR NON-LAMINAR FLOW.
FLOW METERS SHALL BE INSTALLED ACCORDING TO THE MANUFACTURER’S RECOMMENDATION BASED ON•AT THE COMPRESSOR CAN BE ELIMINATED.
COMPRESSOR IS CONTINUOUS FROM THE COMPRESSOR TO THE AERATION PIPE INLET, THE FLOW METER
THE AERATION PIPELINES AT EACH INLET. IN APPLICATIONS WHERE THE FEED LINE FROM THE
FLOW METERS SHALL BE INSTALLED IN THE MAIN LINE AT EACH COMPRESSOR AND AT EACH BRANCH OF•LOWEST PRESSURE IN EACH BRANCH OF THE AERATION PIPELINE.
PRESSURE METERS SHALL BE INSTALLED AT ALL INLETS TO AERATION PIPELINES AND AT POINTS OF•METERS SHALL BE PROVIDED AS FOLLOWS:IV.
Vt = 32.91 ft³/min/ft * CIRCUMFERENCE OF THE AERATION RING IN ft
OR
Vt = 3.0 m³/min/m * CIRCUMFERENCE OF THE AERATION RING IN m
PRODUCT OF THE BUBBLE FLUX AND THE CIRCUMFERENCE OF THE RING:
(32.91 ft³ PER MINUTE PER LIN FT OF PIPE IN EACH LAYER). THE TOTAL VOLUME OF AIR PER LAYER IS THE
THE SYSTEM SHALL PROVIDE A BUBBLE FLUX 3.0 m³ PER MINUTE PER LINEAR METER OF PIPE IN EACH LAYERIII.
ALONG THE PIPE TO PROVIDE UNIFORM BUBBLE FLUX.
20 mm (3/4 in) APART. AIR HOLES WITH THIS SIZE AND SPACING SHALL BE PLACED IN 4 ADJACENT ROWS
AIR HOLES SHALL BE 1.6 MILLIMETER (mm) (1/16-in) IN DIAMETER AND SHALL BE SPACED APPROXIMATELYII.
SUBSTRATE WITHOUT BURIAL AND SHALL ACCOMMODATE SLOPED CONDITIONS.
THE LOWEST LAYER OF PERFORATED AERATION PIPE SHALL BE DESIGNED TO ENSURE CONTACT WITH THEI.
A RADIAL DIMENSION SUCH THAT THE RINGS ARE NO MORE THAN 0.5 m FROM THE OUTSIDE SURFACE OF THE PILE.
BEING DRIVEN TO BE COMPLETELY ENCLOSED BY BUBBLES FOR THE FULL DEPTH OF THE WATER COLUMN AND WITH
THE PIPES IN ALL LAYERS SHALL BE ARRANGED IN A GEOMETRIC PATTERN WHICH SHALL ALLOW FOR THE PILEC.
VERTICALLY IN ACCORDANCE WITH THE FOLLOWING:
THE AERATION PIPE SYSTEM SHALL CONSIST OF MULTIPLE LAYERS OF PERFORATED PIPE RINGS, STACKEDB.
3
GENERAL NOTES (2 OF 2)
MATLACHA FISHING PIER REPLACEMENT
5.67
5.64
4.04
7
-0.13
-0.14
3.43
2
-0.95
5.11
2
-0.99
-1.86
-0.99
-0.55
-0.42
-0.94
-1.52
-2.30
-3.20
-1.51
-1.55
-1.51
-1.60
-1.70
-1.53
-2.13
-2.42
-3.03
-0.53
-0.77
-0.74
-0.66
-0.79
-1.26
-0.95
-1.05
-1.16
-1.02
-0.90
-0.63
-0.97
-0.32
-0.69
-0.47
-0.28
-0.35
-0.52
-0.24
-0.43
-1.09
-1.18
-1.42
-1.04
-1.39
-1.54
-1.36
-1.16
-0.72
-0.91
-0.85
-0.65
-0.54
-0.46
-0.28
-0.12
0.06
0.33
0.68
1.69
2.49
2.69 2.
39 1.58 0.
49 0.39
2.91
3.08
2.98
2.96
4.99
4.84
5.05
4.76
5.06
5.09
5.06
5.25
5.27
5.44
5.12
5.115.12
5.25
4.985.24
5.28
5.28
5.34
5.11
5.30
5.40
4.81
4.12
4.88
4.79
4.81
4.64
4.704.
59
3.04
4.53
4.86
4.07
2.63
3.182.
92
2.75
4.37
4.96
4.50
4.48
3.532.
52
3.62
2.75
2.87
3.76
4.36
4.90
5.34
5.45
5.49
5.48
5.56
5.36
5.34
5.37
5.16
5.42
4.99
5.19
5.22
5.31
5.25
5.28
5.23
5.24
5.08
5.18
2.87
4.14
2.74
4.09
2.88
3.76
4.14
4.09
4.30
4.09
3.43
4.63
2.60
4.03
4.56
4.60
3.91
4.69
4.66
4.52
4.71
3.02
4.24
3.14
3.31 3.
122.71
3.89
4.89
4.02
0.53
2.50
2.89
2.85
3.57 2.
80
2.71
0.18
PIE
R
OFF
NE
TTIN
G
CAS
T
NO
PIE
R
OFF
NE
TTIN
G
CAS
T
NO
XX.XX
5.89
X.XX
6.05
5.60
5.96 5.
84
5.81
5.80
5.75
5.80
5.76
6.00
5.81P
IER
OFF
NE
TTIN
G
CAS
T
NO
TOTAL AREA = 44.0 SF
APPROXIMATE NO. PILES = 80
AREA 10" DIA. PILES = 0.55 SF
EXISTING TIMBER PILES:2.
APPROXIMATE EXISTING TIMBER DECK AREA = 3020 SF1.
WOOD
TH
E
OF
FI
CI
AL
RE
CO
RD
OF
THI
S
SH
EE
T I
S
TH
E
EL
EC
TR
ONI
C
FI
LE
DI
GI
TA
LL
Y
SI
GN
ED
AN
D
SE
AL
ED
UN
DE
R
RU
LE 61
G15-23.004,
F.
A.
C.
SDS 6/19
CLH 6/19
RMW 6/19
VAZ 6/19REGISTRY NO. 27559
FORT MYERS, FL 33901
SUITE 200
2121 MCGREGOR BOULEVARD
HIGHSPANS ENGINEERING, INC.
P.E. LICENSE NUMBER 60524
VINCENT ZALIAUSKAS, P.E.
EXISTING CONDITIONS
EXISTING CONCRETE PATH
EXISTING SAND PATH
TREE & ROCK LINE
TREE LINE
±10'-
0"
±70'-
6"
±230'-0"
±16'-0"±184'-0"±30'-0" RAMP
±22'-
0"
±38'-
6"
LEGEND
EXISTING ASPHALT PATH
EXISTING GROUND ELEVATION
EXISTING DECK ELEVATION
TO REMAIN
EXISTING SIGN
TO REMAIN
TRASH CAN
EXISTING
RAMP
±16'-0"
TO BE REPLACED
EXISTING BENCH
TO BE REPLACED
EXISTING BENCH
TO BE REPLACED
EXISTING CLEANING STATION
TO BE REPLACED
EXISTING SIGN
TO BE REPLACED
EXISTING SIGN
EXISTING DRIVEWAY
AND PILINGS TO BE REMOVED
EXISTING TIMBER PIER
4
TO BE REPLACED
EXISTING LIGHT POLE
TO BE REPLACED
EXISTING LIGHT POLE
TO BE REPLACED
EXISTING LIGHT POLE
TO BE REPLACED
EXISTING LIGHT POLE
TO BE REPLACED
EXISTING TRASH CAN
AND TIMBER PILE CAP (TYP.)
EXISTING 10" DIA. TIMBER PILES
NOTES
REF. DWG. NO.
SHEET NO.
SHEET TITLE:
PROJECT NAME:
DRAWN BY:
CHECKED BY:
DESIGNED BY:
CHECKED BY:
ROAD NO. COUNTY PROJECT NO.
REVISIONS
DATE BY DESCRIPTION DATE BY DESCRIPTION
LEE
Sabrina 10/11/2019 12:27:02 PM H:\_Project18\1812_MatlachaPier\struct\ExistingConditions.DGN
CONSTRUCTION & MANAGEMENT
LEE COUNTY FACILITIES
MATLACHA FISHING PIER REPLACEMENT
MA
TC
HLIN
EM
AT
CH
LIN
E
SIDEWALK
LEVEL PAD
8'-6"
WATER
TH
E
OF
FI
CI
AL
RE
CO
RD
OF
THI
S
SH
EE
T I
S
TH
E
EL
EC
TR
ONI
C
FI
LE
DI
GI
TA
LL
Y
SI
GN
ED
AN
D
SE
AL
ED
UN
DE
R
RU
LE 61
G15-23.004,
F.
A.
C.
SDS 6/19
CLH 6/19
RMW 6/19
VAZ 6/19REGISTRY NO. 27559
FORT MYERS, FL 33901
SUITE 200
2121 MCGREGOR BOULEVARD
HIGHSPANS ENGINEERING, INC.
P.E. LICENSE NUMBER 60524
VINCENT ZALIAUSKAS, P.E.
MAIN PIER PLAN VIEW
2"x10" PT STRINGER
2"x6" DECK
0
-5
5
10
15
-10
10'-
0"
MAIN PIER ELEVATION VIEW
0
-5
5
10
15
-10
PLAN AND ELEVATION (1 OF 3)
EL. = 7.1'
FINISHED DECK
GROUND
EXISTING
8'-0" PILE
SPACING (TYP.)
SPACING (TYP.)
8'-0" PILE14" CONCRETE PILE (TYP.)
EL. = ±5.8'
EXISTING DECK
CONCRETE SIDEWALK
MATCH EXISTING
EL. = ±4.5'
EXISTING
EL. = ±4.7'
EXISTING
EL. = ±4.7'
EXISTING
4'-
0"
4'-
0"
CONNECT TO EXISTING WATERLINE
27'-6" RAMP @ 1:12 SLOPE MAX. 183'-6" MAIN PIER
WATERLINE
2" PVC, SCHEDULE 80INSTALL WATER VALVE
EXISTING CONCRETE PATH
EXISTING SAND PATH
LEGEND
EXISTING ASPHALT PATH
183'-6" MAIN PIER27'-6" RAMP @ 1:12 SLOPE MAX.
PROPOSED CONCRETE PATH
EL. = ±5.1'
EXISTING
SIDEWALK
CONCRETE
EL. = 4.8'
END RAMP
8'-6" CONC.
6'-0" MIN. 5'-2" O.C. RAMP
(INDEX 400-011)
GRAVITY WALL
(INDEX 400-011)
PROPOSED GRAVITY WALL
5'-0"
MIN.
ELECTRIC
2" PVC, SCHEDULE 80
CONNECT TO EXISTING ELECTRIC
6'-0" MAIN PIER
SPACING (TYP.)
RAILING POSTS
SPACING (TYP.)
RAILING POST
6'-0" MAIN PIER
SPACING (TYP.)
RAILING POSTS
5'-2"
5'-2" O.C. RAMP
SPACING (TYP.)
RAILING POST
RAILING, TYPE 2 (INDEX 515-062)
ALUMINUM PEDESTRIAN/BICYCLE
CONCRETE PILE CAP (TYP.)
PROPOSED LIGHT POLE
2'-0"
1'-6"
3'-2"
SUBMIT SHOP DRAWING FOR APPROVAL
PROPOSED BOLLARD (TYP.)
5
PROPOSED LIGHT POLE
MHW= 1.14
14"x14" CONCRETE PILE (TYP.)
REF. DWG. NO.
SHEET NO.
SHEET TITLE:
PROJECT NAME:
DRAWN BY:
CHECKED BY:
DESIGNED BY:
CHECKED BY:
ROAD NO. COUNTY PROJECT NO.
REVISIONS
DATE BY DESCRIPTION DATE BY DESCRIPTION
LEE
Sabrina 10/11/2019 12:27:03 PM H:\_Project18\1812_MatlachaPier\struct\B1PlanElev01.DGN
CONSTRUCTION & MANAGEMENT
LEE COUNTY FACILITIES
MATLACHA FISHING PIER REPLACEMENT
TH
E
OF
FI
CI
AL
RE
CO
RD
OF
THI
S
SH
EE
T I
S
TH
E
EL
EC
TR
ONI
C
FI
LE
DI
GI
TA
LL
Y
SI
GN
ED
AN
D
SE
AL
ED
UN
DE
R
RU
LE 61
G15-23.004,
F.
A.
C.
SDS 6/19
CLH 6/19
RMW 6/19
VAZ 6/19REGISTRY NO. 27559
FORT MYERS, FL 33901
SUITE 200
2121 MCGREGOR BOULEVARD
HIGHSPANS ENGINEERING, INC.
P.E. LICENSE NUMBER 60524
VINCENT ZALIAUSKAS, P.E.
PIE
R
OFF
NE
TTIN
G
CAS
T
NO
PIE
R
OFF
NE
TTIN
G
CAS
T
NO
REF. DWG. NO.
SHEET NO.
SHEET TITLE:
PROJECT NAME:
DRAWN BY:
CHECKED BY:
DESIGNED BY:
CHECKED BY:
ROAD NO. COUNTY PROJECT NO.
REVISIONS
DATE BY DESCRIPTION DATE BY DESCRIPTION
LEE
Sabrina 10/11/2019 12:27:04 PM H:\_Project18\1812_MatlachaPier\struct\B1PlanElev02.DGN
CONSTRUCTION & MANAGEMENT
LEE COUNTY FACILITIES
MAIN PIER PLAN VIEW
2"x10" PT STRINGER
2"x6" DECK
0
-5
5
10
15
-10
10'-
0"
MAIN PIER ELEVATION VIEW
0
-5
5
10
15
-10
PLAN AND ELEVATION (2 OF 3)
T-HEAD PIER
EXISTING GROUND
EL. = 7.1'
FINISHED DECK
14" CONCRETE PILE (TYP.)
8'-0" PILE
SPACING (TYP.)
SPACING (TYP.)
8'-0" PILE
MA
TC
HLIN
EM
AT
CH
LIN
E
EL. = ±5.8'
EXISTING DECK
BIN
RECYCLE
CAN &
TRASH
ATTACH TO RAILING
18"x24"
183'-6" MAIN PIER 16'-0"
CONCRETE PILE CAP (TYP.)
WATERLINE
2" PVC, SCHEDULE 80
ELECTRIC
2" PVC, SCHEDULE 80
PROPOSED LIGHT POLE
6'-0" MAIN PIER
SPACING (TYP.)
RAILING POSTS
RAILING, TYPE 2 (INDEX 515-062)
ALUMINUM PEDESTRIAN/BICYCLE
SPACING (TYP.)
RAILING POSTS
6'-0" MAIN PIER
BENCH
6
CLEANING STATION
ADA COMPLIANT FISH
FISH CLEANING STATION
183'-6" MAIN PIER
T-HEAD PIER
16'-0"
PROPOSED LIGHT POLE
MO
ORIN
G
NO
OUTSIDE RAILING
ATTACH TO THE
18"x24"
INSIDE RAILING
ATTACH TO THE
18"x24"
MHW= 1.14
14"x14" CONCRETE PILE (TYP.)
MATLACHA FISHING PIER REPLACEMENT
TH
E
OF
FI
CI
AL
RE
CO
RD
OF
THI
S
SH
EE
T I
S
TH
E
EL
EC
TR
ONI
C
FI
LE
DI
GI
TA
LL
Y
SI
GN
ED
AN
D
SE
AL
ED
UN
DE
R
RU
LE 61
G15-23.004,
F.
A.
C.
SDS 6/19
CLH 6/19
RMW 6/19
VAZ 6/19REGISTRY NO. 27559
FORT MYERS, FL 33901
SUITE 200
2121 MCGREGOR BOULEVARD
HIGHSPANS ENGINEERING, INC.
P.E. LICENSE NUMBER 60524
VINCENT ZALIAUSKAS, P.E.
PIER
OFF
NETTING
CAST
NO
REF. DWG. NO.
SHEET NO.
SHEET TITLE:
PROJECT NAME:
DRAWN BY:
CHECKED BY:
DESIGNED BY:
CHECKED BY:
ROAD NO. COUNTY PROJECT NO.
REVISIONS
DATE BY DESCRIPTION DATE BY DESCRIPTION
LEE
Sabrina 10/11/2019 12:27:06 PM H:\_Project18\1812_MatlachaPier\struct\B1PlanElev03.DGN
CONSTRUCTION & MANAGEMENT
LEE COUNTY FACILITIES
T-HEAD PIER PLAN VIEW
T-HEAD PIER ELEVATION VIEW
16'-
0"
73'-2" T-HEAD PIER
73'-2" T-HEAD PIER
39'-7"10'-0" MAIN PIER23'-7"
1'-
2"
GROUND
EXISTING
PLAN AND ELEVATION (3 OF 3)
-10
-5
0
5
10
15
-10
-5
0
5
10
15
STRINGER
2"x10" PT
EL. = 7.1'
FINISHED DECK
SPACING (TYP.)
8'-0" PILE
8'-0" PILE
SPACING (TYP.)
7'-0"
7'-0"
EL. = ±5.8'
EXISTING DECK
2'-
6"
9"
BIN
RECYCLE
CAN &
TRASH
CAP (TYP.)
CONCRETE PILE
WATERLINE
2" PVC, SCHEDULE 80
BENCHBENCH
"215'-4"2
15'-4"215'-4"2
15'-4 6'-3"6'-3"6'-3"6'-3"6'-3"6'-3"
7'-
0"
7'-
0"
5'-11"5'-11"5'-11"5'-11"5'-11"5'-11"5'-11"5'-11"5'-11"5'-11"5'-11"5'-11"
(TYP.)
PILE
CONRETE
14"x14"
1'-1" 1'-1"
1'-
0"
1'-
0"
1'-0" 1'-0"
7'-
0"
7'-
0"
1'-
0"
1'-1"
SP
ACIN
G
RAILIN
G P
OS
T
SPACING
RAILING POST
LIGHT POLE
PROPOSED
1'-
0"
SP
ACIN
G
RAILIN
G P
OS
T
1'-1"
SPACING
RAILING POST
LIGHT POLE
PROPOSED
RAILING, TYPE 2 (INDEX 515-062)
ALUMINUM PEDESTRIAN/BICYCLE5'-2"
3'-
6"
SPACING
RAILING POST
5'-2"
RAILING
ATTACH TO
18"x24"
7
(TYP.)
CONCRETE PILE
14"x14"
FISH CLEANING STATION
CLEANING STATION
ADA COMPLIANT FISH
LIGHT POLE
PROPOSEDLIGHT POLE
PROPOSED
MO
ORIN
GNO
OUTSIDE RAILING
ATTACH TO THE
18"x24"
MO
ORIN
G
NO
OUTSIDE RAILING
ATTACH TO THE
18"x24"
ELECTRIC
SCHEDULE 80
2" PVC,ELECTRIC
SCHEDULE 80
2" PVC,
MHW= 1.14
2"x6" DECK
MATLACHA FISHING PIER REPLACEMENT
TH
E
OF
FI
CI
AL
RE
CO
RD
OF
THI
S
SH
EE
T I
S
TH
E
EL
EC
TR
ONI
C
FI
LE
DI
GI
TA
LL
Y
SI
GN
ED
AN
D
SE
AL
ED
UN
DE
R
RU
LE 61
G15-23.004,
F.
A.
C.
SDS 6/19
CLH 6/19
RMW 6/19
VAZ 6/19REGISTRY NO. 27559
FORT MYERS, FL 33901
SUITE 200
2121 MCGREGOR BOULEVARD
HIGHSPANS ENGINEERING, INC.
P.E. LICENSE NUMBER 60524
VINCENT ZALIAUSKAS, P.E.
16'-0"
1'-
0"
2'-
0"
1'-
0"
10'-0"
1'-6"3'-6"3'-6"1'-6" 1'-6"6'-6"6'-6"1'-6"
8'-0"8'-0"5'-0"5'-0"
3'-
6"
"2
13'-
0
2'-
0"
3'-
6"
"2
13'-
0
"2
16'-
6
"4
12'-
7
3"
CL
R.
"2
16'-
6
"4
12'-
7"
43
10
3"
CL
R.
ATTACHED TO STRINGER
2" PVC WATERLINE
(INDEX 515-062)
PED./BICYCLE RAILING
"4
310
6"x1/4" ALUMINUM PLATE
2"x6" HANDRAIL
ATTACHED TO STRINGER
2" PVC ELECTRIC
6"x1/4" ALUMINUM PLATE
2"x6" HANDRAIL
2"x2" POST,TYPE B 2"x2" POST,TYPE B
ATTACHED TO STRINGER
2" PVC ELECTRIC
(INDEX 515-062)
PED./BICYCLE RAILING
REF. DWG. NO.
SHEET NO.
SHEET TITLE:
PROJECT NAME:
DRAWN BY:
CHECKED BY:
DESIGNED BY:
CHECKED BY:
ROAD NO. COUNTY PROJECT NO.
REVISIONS
DATE BY DESCRIPTION DATE BY DESCRIPTION
LEE
Sabrina 10/11/2019 12:27:06 PM H:\_Project18\1812_MatlachaPier\struct\B1TypicalSection01.DGN
CONSTRUCTION & MANAGEMENT
LEE COUNTY FACILITIES
T-HEAD TYPICAL SECTIONMAIN PIER TYPICAL SECTION
16'-0"
2"x10" PT STRINGERS
STRINGERS
2"x10" PT
10'-0"
PILES (TYP.)
14"x14" CONCRETE
(MA
X.)
RAILING
INSIDE FACE OF
FABRIC TIED TO
CHAIN-LINK FENCE
2"x2" BOTTOM RAIL
3" CONT. TOP RAIL
RAILING
INSIDE FACE OF
FABRIC TIED TO
CHAIN-LINK FENCE
2"x2" BOTTOM RAIL
(MA
X.)
BASE PLATE, TYPE A
2"x2" INTERMEDIATE RAIL
BASE PLATE, TYPE A
3" TOP RAIL
2"x2" INTERMEDIATE RAIL
TYPICAL SECTIONS (1 OF 3)
8
SS DECK SCREWS
ATTACHED W/ (2) #10x3" (MIN.)
GAP BETWEEN BOARDS AND
" (MAX.)212"x6" DECK BOARDS W/
SS DECK SCREWS
ATTACHED W/ (2) #10x3" (MIN.)
GAP BETWEEN BOARDS AND
" (MAX.)212"x6" DECK BOARDS W/
PILES (TYP.)
14"x14" CONCRETE
MATLACHA FISHING PIER REPLACEMENT
WATER
TH
E
OF
FI
CI
AL
RE
CO
RD
OF
THI
S
SH
EE
T I
S
TH
E
EL
EC
TR
ONI
C
FI
LE
DI
GI
TA
LL
Y
SI
GN
ED
AN
D
SE
AL
ED
UN
DE
R
RU
LE 61
G15-23.004,
F.
A.
C.
SDS 6/19
CLH 6/19
RMW 6/19
VAZ 6/19REGISTRY NO. 27559
FORT MYERS, FL 33901
SUITE 200
2121 MCGREGOR BOULEVARD
HIGHSPANS ENGINEERING, INC.
P.E. LICENSE NUMBER 60524
VINCENT ZALIAUSKAS, P.E.
TYPICAL SECTIONS (2 OF 3)
@ HANDRAIL POSTS
DOUBLE PT BLOCKING
6'-0" O.C. (TYP.)
"8
51'-
5"
85
1'-
7"
85
1'-
7"
85
1'-
7"
85
1'-
7"
85
1'-
5
STRINGER
2"x10" PT
1'-5"1'-7"1'-7"1'-7"1'-7"1'-7"1'-7"1'-7"1'-7"1'-5"
STRINGER
2"x10" PT
2"x10" PT FASCIA
@ HANDRAIL POSTS
DOUBLE PT BLOCKING
1'-0"
HANDRAIL POST
PT BLOCKING @
8'-
0"
O.C. (T
YP.)
CONNECTION DETAIL
SEE STRINGER
CONNECTION DETAIL
SEE STRINGER
2'-2"
CONNECTION DETAIL
SEE STRINGER
PILE
CONCRETE
14"x14"
8'-0" O.C. (TYP.)
1'-
0"2'-
0"
MAIN PIER PLAN VIEW TYPICAL SECTION DETAILT-HEAD PIER PLAN VIEW TYPICAL SECTION DETAIL
TYPICAL SECTION ELEVATION VIEW DETAIL
"2
16'-
6
3'-
6"
"2
13'-
0
"4
12'-
0"
43
7
3"
CL
R.
(MA
X.)
2"x2" BOTTOM RAIL
2"x6" DECKING
WALL
8" GRAVITY
2"
3"
2'-2"
CONNECTION DETAIL
SEE STRINGER
2"x10" PT STRINGER
PILE
CONCRETE
14"x14"
8'-0" O.C. (TYP.)
1'-
0"2'-
0"
"2
16'-
6
3' -
6"
"2
13'-
0
"4
12'-
0"
43
72"
CL
R.
(MA
X.)
2"x2" BOTTOM RAILS
2"x6" DECKING
ADA COMPLIANT TYPICAL SECTION ELEVATION VIEW DETAIL
NOTCH (TYP.)
IN GRAVITY WALL
SET STRINGERS
2"x2" INTERMEDIATE RAIL
2"x2" INTERMEDIATE RAILS
16'-8"
10'-
8"
@ HANDRAIL POST
PT BLOCKING
OF INTERIOR STRINGERS
SS SCREWS AT EACH END
(3) #10x 3" (MIN.)
RAIL POST, TYPE B (TYP.)
OF EXTERIOR STRINGERS
SS SCREWS AT EACH END
(3) #12x 5" (MIN.)
PILE, CAP POST SPACING
RAIL POST, TYPE B (TYP.)RAIL POST, TYPE B (TYP.)
SHOWN FOR CLARITY
3" TOP RAIL NOT
SHOWN FOR CLARITY
3" TOP RAIL NOT
PILE, CAP POST SPACING
2"X2" POST, TYPE B (TYP.)
OF EXTERIOR STRINGERS
SS SCREWS AT EACH END
(3) #12x 5" (MIN.)
OF INTERIOR STRINGERS
SS SCREWS AT EACH END
(3) #10x 3" (MIN.)
STRINGER
2"x10" PT
NOT SHOWN FOR CLARITY)
3" TOP RAIL (HANDRAIL
CONNECTION DETAIL
SEE RAIL POST
9
REF. DWG. NO.
SHEET NO.
SHEET TITLE:
PROJECT NAME:
DRAWN BY:
CHECKED BY:
DESIGNED BY:
CHECKED BY:
ROAD NO. COUNTY PROJECT NO.
REVISIONS
DATE BY DESCRIPTION DATE BY DESCRIPTION
LEE
Sabrina 10/11/2019 12:27:08 PM H:\_Project18\1812_MatlachaPier\struct\B1TypicalSection02.DGN
CONSTRUCTION & MANAGEMENT
LEE COUNTY FACILITIES
MATLACHA FISHING PIER REPLACEMENT
TH
E
OF
FI
CI
AL
RE
CO
RD
OF
THI
S
SH
EE
T I
S
TH
E
EL
EC
TR
ONI
C
FI
LE
DI
GI
TA
LL
Y
SI
GN
ED
AN
D
SE
AL
ED
UN
DE
R
RU
LE 61
G15-23.004,
F.
A.
C.
SDS 6/19
CLH 6/19
RMW 6/19
VAZ 6/19REGISTRY NO. 27559
FORT MYERS, FL 33901
SUITE 200
2121 MCGREGOR BOULEVARD
HIGHSPANS ENGINEERING, INC.
P.E. LICENSE NUMBER 60524
VINCENT ZALIAUSKAS, P.E.
(INDEX 515-062)
PED./BICYCLE RAILING
2"x2" POST, TYPE B
REF. DWG. NO.
SHEET NO.
SHEET TITLE:
PROJECT NAME:
DRAWN BY:
CHECKED BY:
DESIGNED BY:
CHECKED BY:
ROAD NO. COUNTY PROJECT NO.
REVISIONS
DATE BY DESCRIPTION DATE BY DESCRIPTION
LEE
Sabrina 10/11/2019 12:27:09 PM H:\_Project18\1812_MatlachaPier\struct\B1TypicalSection03.DGN
CONSTRUCTION & MANAGEMENT
LEE COUNTY FACILITIES
TYPICAL SECTIONS (3 OF 3)
4'-2"
1" 1"
1'-6"6'-0"
1'-
0"
1'-
0"
RAMP TYPICAL SECTION
MAIN PIER AND T-HEAD CONNECTION DETAIL
T-HEAD
1'-
0"
T-HEAD1'-6"6'-0"
1'-
0"
4'-2"
1" 1"
RAILING
POST (TYP.)
RAILING
RAILING
POST (TYP.)
RAILING
2'-
2"
PILE C
AP
2'-2" PILE CAP 2'-2" PILE CAP
2'-
2"
PILE C
AP
HANDRAIL POST
PT BLOCKING @
CONNECTION DETAIL
SEE INTERIOR STRINGER
CONNECTION DETAIL
SEE EXTERIOR STRINGER
STRINGER
2"x10" PT
2" GAP
5"
4'-
10"
5"
@ HANDRAIL POST
DOUBLE PT BLOCKING
ATTACHED TO RAILING
MONOFILAMENT BIN
4'-0" CLEANING STATION
2'-
0"
CLE
ANIN
G
ST
ATIO
N
ST
ATIO
N
2'-
0"
CLE
ANIN
G
4'-0" CLEANING STATION
ATTACHED TO RAILING
MONOFILAMENT BIN
(INDEX 400-011)
GRAVITY WALL
SEE CONNECTION DETAIL
8" 8"
"4
12'-
7"
43
10
OF INTERIOR STRINGERS
SS SCREWS AT EACH END
(3) #10x 3" (MIN.)
OF INTERIOR STRINGERS
SS SCREWS AT EACH END
(3) #12x 5" (MIN.)
ATTACHED TO RAILING
FISH DISPOSAL TUBE
ATTACHED TO RAILING
FISH DISPOSAL TUBE
2"x2" INTERMEDIATE RAIL
RAILING
INSIDE FACE OF
FABRIC TIED TO
CHAIN-LINK FENCE
3'-
6"
2'-
3"
2'-
0" (M
IN.)
"214'-11"2
14'-11
CONCRETE SIDEWALK
4" THICK
3" TOP RAIL
2"x2" BOTTOM RAIL
BASE PLATE, TYPE A
10 MATLACHA FISHING PIER REPLACEMENT
TH
E
OF
FI
CI
AL
RE
CO
RD
OF
THI
S
SH
EE
T I
S
TH
E
EL
EC
TR
ONI
C
FI
LE
DI
GI
TA
LL
Y
SI
GN
ED
AN
D
SE
AL
ED
UN
DE
R
RU
LE 61
G15-23.004,
F.
A.
C.
SDS 6/19
CLH 6/19
RMW 6/19
VAZ 6/19REGISTRY NO. 27559
FORT MYERS, FL 33901
SUITE 200
2121 MCGREGOR BOULEVARD
HIGHSPANS ENGINEERING, INC.
P.E. LICENSE NUMBER 60524
VINCENT ZALIAUSKAS, P.E.
EACH PILE
2-4MC01 @
@ 6" O.C.
4MC02
4MC03
4MC03
4MC03
4MC03
4MC03
4MC04
4MC04
4MC04
4MC04
3-4MC05
3-4MC05
4MC06 @ 6" O.C.
4MC06 @ 6" O.C.
PILE DOWELS
2-8MC10
EACH PILE
2-4MC01 @ 3" O.C.
12-4MC02 @ 6" O.C.
12-4MC02 @ 6" O.C.
EACH PILE
2-4MC01 @ 3" O.C.
PILE DOWELS
2-8MC0. @ 7" O.C.
PILE DOWELS
2-8MC07 @ 7" O.C.
@ 5" O.C.2-4MC02
@ 5" O.C.2-4MC02
REF. DWG. NO.
SHEET NO.
SHEET TITLE:
PROJECT NAME:
DRAWN BY:
CHECKED BY:
DESIGNED BY:
CHECKED BY:
ROAD NO. COUNTY PROJECT NO.
REVISIONS
DATE BY DESCRIPTION DATE BY DESCRIPTION
LEE
Sabrina 10/11/2019 12:27:09 PM H:\_Project18\1812_MatlachaPier\struct\B1TypicalSection04.DGN
CONSTRUCTION & MANAGEMENT
LEE COUNTY FACILITIES
PILES
¡ CAP &
4" CLR.
(TYP.)
2'-
0"
PILES
¡ CAP &
14"x14" CONCRETE PILE
10'-0"
2'-
2"
10'-0"
2'-
0"
PILE CAP DETAILS (1 OF 2)
14"x14" CONCRETE PILE14"x14" CONCRETE PILE
2'-2"
1'-1"1'-1"(TYP.)
" CHAMFER43
2'-2"
1'-1"1'-1"(TYP.)
" CHAMFER43
2'-
0"
4" CLR.
(TYP.)
MAIN PIER PILE CAP PLAN VIEW
MAIN PIER PILE CAP ELEVATION VIEW
CAP DETAIL BETWEEN PILES
CAP DETAIL AT PILES
11 MATLACHA FISHING PIER REPLACEMENT
TH
E
OF
FI
CI
AL
RE
CO
RD
OF
THI
S
SH
EE
T I
S
TH
E
EL
EC
TR
ONI
C
FI
LE
DI
GI
TA
LL
Y
SI
GN
ED
AN
D
SE
AL
ED
UN
DE
R
RU
LE 61
G15-23.004,
F.
A.
C.
SDS 6/19
CLH 6/19
RMW 6/19
VAZ 6/19REGISTRY NO. 27559
FORT MYERS, FL 33901
SUITE 200
2121 MCGREGOR BOULEVARD
HIGHSPANS ENGINEERING, INC.
P.E. LICENSE NUMBER 60524
VINCENT ZALIAUSKAS, P.E.
EACH PILE
2-4TC01 @
EACH PILE
2-4TC01 @
2-4TC02
2-4TC022-4TC02
4TC03 4TC04
4TC044TC06 @ 6" O.C. PILE DOWELS
2-8TC07
PILE DOWELS
2-8TC074TC06 @ 6" O.C.
8-4CC02 2-4CC026-4CC02
4CC03PILE DOWELS
2-8CC074CC06 @ 6" O.C.
EACH PILE
2-4CC01 @
@ 6" O.C.
4TC02/4CC02
4TC03/4CC03
4TC03/4CC03
4TC03/4CC03
4CC04
4TC04/4CC04
4TC04/4CC04
3-4CC05 3-4CC053-4CC08
PILE DOWELS
2-8TC07/8CC07
@ EACH PILE
2-4TC01/4CC01
3-4TC05/4CC05/4CC08
11-4TC02
11-4TC02@ 5" O.C.2-4TC02
ANCHOR BOLTS
17x3x3/4" GS
@ 6" O.C.
4MEC06/4TEC06
@ 5" O.C.
6-4MEC02/4TEC02
EACH PILE
@ 3" O.C.
2-4MEC01/4TEC01
4MEC04/4TEC04
4TC05
4MEC05/4TEC05
6-4TC03/4CC03
11-4TC02 @ 6" O.C.
11-4TC02 @ 6" O.C.
8-4CC02 @ 6" O.C.
REF. DWG. NO.
SHEET NO.
SHEET TITLE:
PROJECT NAME:
DRAWN BY:
CHECKED BY:
DESIGNED BY:
CHECKED BY:
ROAD NO. COUNTY PROJECT NO.
REVISIONS
DATE BY DESCRIPTION DATE BY DESCRIPTION
LEE
Sabrina 10/11/2019 12:27:10 PM H:\_Project18\1812_MatlachaPier\struct\B1TypicalSection05.DGN
CONSTRUCTION & MANAGEMENT
LEE COUNTY FACILITIES
2'-
0"
14"x14" CONCRETE PILE
2'-
2"
2'-
0"
T-HEAD PILE CAP PLAN VIEW
CAP DETAIL AT PILES
(TYP.)
" CHAMFER43
(TYP.)
" CHAMFER43
16'-0"
T-HEAD PILE CAP ELEVATION VIEW
1'-6"6'-6"6'-6"1'-6"
1'-6"6'-6"6'-6"1'-6"
2'-2"
4" CLR. (TYP.)
T-HEAD PILE CAP @ MAIN PIER CONNECTION SIMILAR
14'-11"
14"x14" CONCRETE PILE
1'-6"5'-0"5'-0"3'-5"
14"x14" CONCRETE PILE
T-HEAD PILE CAP @ MAIN PIER CONNECTION ELEVATION VIEW
PILES
¡ CAP &
4" CLR. (TYP.)
1'-1"1'-1"
2'-2"
1'-1"1'-1"
PILE CAP DETAILS (2 OF 2)
¡ CAP
LIGHT POLE DETAIL
2'-
0"
3'-6"
11"
12
(SIMILAR TO T-HEAD)
SHOWN FOR MAIN PIER
CAP EXTENSION DETAILS
LIGHT POLE
12'x4"x1/8" ALUMINUM
CAP DETAIL BETWEEN PILES
MATLACHA FISHING PIER REPLACEMENT
MAIN PIER LOOKING SOUTH
MAIN PIER LOOKING NORTH
MAIN PIER LOOKING EAST
TH
E
OF
FI
CI
AL
RE
CO
RD
OF
THI
S
SH
EE
T I
S
TH
E
EL
EC
TR
ONI
C
FI
LE
DI
GI
TA
LL
Y
SI
GN
ED
AN
D
SE
AL
ED
UN
DE
R
RU
LE 61
G15-23.004,
F.
A.
C.
SDS 6/19
CLH 6/19
RMW 6/19
VAZ 6/19REGISTRY NO. 27559
FORT MYERS, FL 33901
SUITE 200
2121 MCGREGOR BOULEVARD
HIGHSPANS ENGINEERING, INC.
P.E. LICENSE NUMBER 60524
VINCENT ZALIAUSKAS, P.E.
2'-2"
2'-
0"
STRINGER
2"x10" PT
CLEANING STATION ELEVATION VIEW
ADA COMPLIANT CLEANING STATION ELEVATION VIEW
3'-
6"
PILE & CAP
CONCRETE
EXISTING GROUND
(INDEX 515-062)
RAILING, TYPE 2
1'-4"4'-0"8"
"212 "2
12
DECKING
2"x6"
WATERLINE
SCHEDULE 80
2" PVC,
3"
3"
TO RAIL
WATERLINE
ATTACH
TABLE POST
2"x2" ALUMINUM
CLEANING STATION TABLE
FAUCET
DISPOSAL TUBE
8" PVC FISH
2'-
0"
2'-2"
2'-
0"
3'-
6"
EXISTING GROUND
1'-4" 4'-0" 8"
"212"2
12
3"
3"
CLEANING STATION TABLE
FAUCET
2'-
0"
(INDEX 515-062)
RAILING, TYPE 2
TO RAIL
WATERLINE
ATTACH
TALBE POST
2"x2" ALUMINUM
9"
1'-
4"
2'-
5"
EXISTING GROUND
DISPOSAL TUBE
8" PVC FISH
WATERLINE
SCHEDULE 80
2" PVC,
PILE & CAP
CONCRETE
STRINGER
2"x10" PT
DECKING
2"x6"
2'-0"
2" 1'-3"10"
7"
1" 1"
"2
1"
21
"2
12'-
5
1"
4"3"
9"
2'-
5"
7"
1'-0"
2"
POST
ALUMINUM
2"x2"
TO RAIL
WATERLINE
ATTACH
RAIL
2"x2"
RAIL
2"x2"
WATERLINE
SCHEDULE 80
2" PVC,STRINGER
2"x10" PT
DECKING
2"x6"
2'-0"
2"
1"1"
"2
1"
21
"2
13'-
6
1"
4" 3"
3"
3'-
6"
7"
1'-0"
TO RAIL
WATERLINE
ATTACH
POST
ALUMINUM
2"x2"
RAIL
2"x2"
"211
"217
"211'-2 10"
WATERLINE
SCHEDULE 80
2" PVC,
RAIL
2"x2"DECKING
2"x6"
RAIL
3" DIA.
CLEANING STATION TYPICAL SECTION
TO RAIL
WATERLINE
ATTACH
TO RAIL
WATERLINE
ATTACH
TO RAIL POST
ATTACH TUBE
TO RAIL POST
ATTACH TUBE
FISH DISPOSAL TUBE DETAIL
RAILING OUTLINE
DECKING
2"x6"
STRINGER
2"x10" PT
DISPOSAL TUBE
8" PVC FISH
CLEANING STATION DETAILS
13
FILLET WELD.
"41WELDED WITH
" ALUMINUM PLATE 41
REF. DWG. NO.
SHEET NO.
SHEET TITLE:
PROJECT NAME:
DRAWN BY:
CHECKED BY:
DESIGNED BY:
CHECKED BY:
ROAD NO. COUNTY PROJECT NO.
REVISIONS
DATE BY DESCRIPTION DATE BY DESCRIPTION
LEE
Sabrina 10/11/2019 12:27:11 PM H:\_Project18\1812_MatlachaPier\struct\B1TypicalSection06.DGN
CONSTRUCTION & MANAGEMENT
LEE COUNTY FACILITIES
MATLACHA FISHING PIER REPLACEMENT
TH
E
OF
FI
CI
AL
RE
CO
RD
OF
THI
S
SH
EE
T I
S
TH
E
EL
EC
TR
ONI
C
FI
LE
DI
GI
TA
LL
Y
SI
GN
ED
AN
D
SE
AL
ED
UN
DE
R
RU
LE 61
G15-23.004,
F.
A.
C.
SDS 6/19
CLH 6/19
RMW 6/19
VAZ 6/19REGISTRY NO. 27559
FORT MYERS, FL 33901
SUITE 200
2121 MCGREGOR BOULEVARD
HIGHSPANS ENGINEERING, INC.
P.E. LICENSE NUMBER 60524
VINCENT ZALIAUSKAS, P.E. REF. DWG. NO.
SHEET NO.
SHEET TITLE:
PROJECT NAME:
DRAWN BY:
CHECKED BY:
DESIGNED BY:
CHECKED BY:
ROAD NO. COUNTY PROJECT NO.
REVISIONS
DATE BY DESCRIPTION DATE BY DESCRIPTION
LEE
Sabrina 10/11/2019 12:27:12 PM H:\_Project18\1812_MatlachaPier\struct\B1TypicalSection07.DGN
CONSTRUCTION & MANAGEMENT
LEE COUNTY FACILITIES
STRINGER
(2) 2"x10" PT
EXTERIOR STRINGER CONNECTION DETAIL
2"x6" DECK
PILE CAP
CONCRETE
2"x6" DECK
PILE CAP
CONCRETE
"41
"4
1
"41"4
1
"4
1
INTERIOR STRINGER CONNECTION DETAIL
STRINGER
2"x10" PT
FILL
SIDEWALK
CONCRETE
4" THICK
POST CONNECTION TO GRAVITY WALL DETAIL
EPOXY BONDED TO CAP
"x8" LONG SS BOLT83
" HOLE167
SS BOLT
" LONG21"x38
3(2)
" HOLE167
5" LONG SS ANGLE
" THICK413"x4"x
" SS DECK SCREW21(2) #10x3
2"x6" DECKING ATTACHED W/
5" LONG SS ANGLE
" THICK413"x4"x
SS PLATE
" THICK41"x5"x2
18
5" LONG SS ANGLE
" THICK854"x8"x
" SS DECK SCREW21(2) #10x3
2"x6" DECKING ATTACHED W/
EPOXY BONDED TO CAP
"x8" LONG SS BOLT83
" HOLE167
SS PLATE
" THICK418"x5"x
SS BOLT
"x6" LONG43
" HOLE87(2)
PIER DETAILS
AND HANGER ASSEMBLY
2" PVC WATERLINE CONDUIT
¡ BOLT & POST
Ɓ" ℅ Stiffener
2"x6" DECKING
STRINGER
2"x10" PT
1"
1"
SS BOLT
"x6" LONG43
(INDEX 400-011)
GRAVITY WALL
(INDEX 515-062)
RAILING
(INDEX 515-062)
RAILING
HANDRAIL AND ROD HOLDER CONNECTION DETAIL
POST CONNECTION TO STRINGER DETAIL
(INDEX 515-061)
SUPPORT BRACKET, SCHEME 3
(INDEX 515-062)
RAILING
HANDRAIL
2"x6" TANDECK
WELDED TO 3" DIA. TOP RAIL
" ALUMINUM PLATE416"x
3" DIA. TOP RAIL
BOLTS @ 18" O.C.
" SS MUSHROOM41
8"
(INDEX 515-062)
CASE IIb
RAILING CONNECTION,
14
TERMINATION (TYP.)
" (MAX.) WELD21
AND EAST SIDE OF THE T-HEAD PIER
EACH ALUMINUM POST ON THE NORTH, SOUTH
ALUMINUM ROD HOLDER WELDED TO
MATLACHA FISHING PIER REPLACEMENT
TH
E
OF
FI
CI
AL
RE
CO
RD
OF
THI
S
SH
EE
T I
S
TH
E
EL
EC
TR
ONI
C
FI
LE
DI
GI
TA
LL
Y
SI
GN
ED
AN
D
SE
AL
ED
UN
DE
R
RU
LE 61
G15-23.004,
F.
A.
C.
SDS 6/19
CLH 6/19
RMW 6/19
VAZ 6/19REGISTRY NO. 27559
FORT MYERS, FL 33901
SUITE 200
2121 MCGREGOR BOULEVARD
HIGHSPANS ENGINEERING, INC.
P.E. LICENSE NUMBER 60524
VINCENT ZALIAUSKAS, P.E. REF. DWG. NO.
SHEET NO.
SHEET TITLE:
PROJECT NAME:
DRAWN BY:
CHECKED BY:
DESIGNED BY:
CHECKED BY:
ROAD NO. COUNTY PROJECT NO.
REVISIONS
DATE BY DESCRIPTION DATE BY DESCRIPTION
LEE
Sabrina 10/11/2019 12:27:12 PM H:\_Project18\1812_MatlachaPier\struct\B1RebarList01.dgn
CONSTRUCTION & MANAGEMENT
LEE COUNTY FACILITIES
REINFORCING BAR LIST
15 MATLACHA FISHING PIER REPLACEMENT
ATTACHMENT II
Dated 9/18/2019
SELF-CERTIFICATION STATEMENT OF COMPLIANCE Within sixty (60) days of completion of the authorized work, submit this form via electronic mail to [email protected] (preferred, not to exceed 15MB) or by standard mail to U.S. Army Corps of Engineers, Enforcement Section, P.O. Box 4970, Jacksonville, FL 32232-0019.
1. Department of the Army Permit Number: SAJ-______-______ (_____-____)
2. Permittee Information: Name: ____________________________________________
Email: ____________________________________________
Address: __________________________________________
__________________________________________
Phone: ___________________________________________
3. Date Authorized Work Started: _________________ Completed: _______________
4. Contact to Schedule Inspection: Name: ____________________________________
Email: ____________________________________
Phone: ___________________________________
5. Description of Authorized Work (e.g. bank stabilization, fill placed within wetlands, docks, dredging, etc.): ________________________________________________________
____________________________________________________________________________
____________________________________________________________________________
6. Acreage or Square Feet of Impacts to Waters of the United States: _________________
7. Describe Mitigation completed (if applicable): __________________________________
____________________________________________________________________________
____________________________________________________________________________
8. Describe any Deviations from Permit (attach drawing(s) depicting the deviations):
____________________________________________________________________________
____________________________________________________________________________ ********************
I certify that all work and mitigation (if applicable) was done in accordance with the limitations and conditions as described in the permit. Any deviations as described above are depicted on the attached drawing(s).
______________________________ Signature of Permittee ______________________________ Printed Name of Permittee
______________________________ Date
ATTACHMENT III
Dated 9/18/2019
COMMENCEMENT NOTIFICATION
Within ten (10) days of initiating the authorized work, submit this form via electronic mail to [email protected] (preferred, not to exceed 15 MB) or by standard mail to U.S. Army Corps of Engineers, Enforcement Section, P.O. Box 4970, Jacksonville, FL 32232-0019. 1. Department of the Army Permit Number: SAJ-_____-______(_____-____) 2. Permittee Information: Name: __________________________________________ Email: __________________________________________ Address: __________________________________________ __________________________________________ Phone: __________________________________________ 3. Construction Start Date: ______________________ 4. Contact to Schedule Inspection:
Name: __________________________________________ Email: __________________________________________ Phone: __________________________________________
______________________________ Signature of Permittee ______________________________ Printed Name of Permittee
______________________________ Date
ATTACHMENT IV
U.S. Army Corps of Engineers Jacksonville District's Programmatic Biological Opinion (JaxBO) Project Design Criteria (PDCs) for In-Water Activities
November 20, 2017
1) (AP.7.) Education and Observation: The permittee must ensure that all personnel
associated with the project are instructed about the potential presence of species protected under the ESA and the Marine Mammal Protection Act (MMPA). All on-site project personnel are responsible for observing water-related activities for the presence of protected species. All personnel shall be advised that there are civil and criminal penalties for harming, harassing, or killing ESA-listed species or marine mammals. To determine which species may be found in the project area, please review the relevant Protected Species List at: http://sero.nmfs.noaa.gov/protected_resources/section_7/threatened_endangered/index.html
2) (AP.8.) Reporting of interactions with protected species: a) Any collision(s) with and/or injury to any sea turtle, sawfish, whale, or sturgeon
occurring during the construction of a project, shall be reported immediately to NMFS’s Protected Resources Division (PRD) at (1-727-824-5312) or by email to [email protected] and [email protected].
b) Smalltooth sawfish: Report sightings to 1-844-SAWFISH or email [email protected]
c) Sturgeon: Report dead sturgeon to 1-844-STURG 911 (1-844-788-7491) or email [email protected]
d) Sea turtles and marine mammals: Report stranded, injured, or dead animals to 1-877-WHALE HELP (1-877-942-5343).
e) North Atlantic right whale: Report injured, dead, or entangled right whales to the USCG via VHF Channel 16.
3) (AP.9.) Vessel Traffic and Construction Equipment: All vessel operators must
watch for and avoid collision with species protected under the ESA and MMPA. Vessel operators must avoid potential interactions with protected species and operate in accordance with the following protective measures: a) Construction Equipment:
i) All vessels associated with the construction project shall operate at “Idle Speed/No Wake” at all times while operating in water depths where the draft of the vessel provides less than a 4-foot (ft) clearance from the bottom, and in all depths after a protected species has been observed in and has departed the area.
ii) All vessels will follow marked channels and/or routes using the maximum water depth whenever possible.
iii) Operation of any mechanical construction equipment, including vessels, shall cease immediately if a listed species is observed within a 50-ft radius of
construction equipment and shall not resume until the species has departed the area of its own volition.
iv) If the detection of species is not possible during certain weather conditions (e.g., fog, rain, wind), then in-water operations will cease until weather conditions improve and detection is again feasible.
b) All Vessels: i) Sea turtles: Maintain a minimum distance of 150 ft. ii) North Atlantic right whale: Maintain a minimum 1,500-ft distance (500 yards). iii) Vessels 65 ft in length or longer must comply with the Right Whale Ship Strike
Reduction Rule (50 CFR 224.105) which includes reducing speeds to 10 knots or less in Seasonal Management Areas (http://www.fisheries.noaa.gov/pr/shipstrike/).
iv) Mariners shall check various communication media for general information regarding avoiding ship strikes and specific information regarding right whale sightings in the area. These include NOAA weather radio, USCG NAVTEX broadcasts, and Notices to Mariners.
v) Marine mammals (i.e., dolphins, whales [other than North Atlantic right whales], and porpoises): Maintain a minimum distance of 300 ft.
vi) When these animals are sighted while the vessel is underway (e.g., bow-riding), attempt to remain parallel to the animal’s course. Avoid excessive speed or abrupt changes in direction until they have left the area.
vii) Reduce speed to 10 knots or less when mother/calf pairs or groups of marine mammals are observed, when safety permits.
4) (AP.10.) Turbidity Control Measures during Construction: Turbidity must be
monitored and controlled. Prior to initiating any of the work covered under this Opinion, the Permittee shall install turbidity curtains as described below. In some instances, the use of turbidity curtains may be waived by the USACE project manager if the project is deemed too minimal to generate turbidity (e.g., certain ATON installation, scientific survey device placement, marine debris removal) or if the current is too strong for the curtains to stay in place. Turbidity curtains specifications: a) Install floating turbidity barriers with weighted skirts that extend to within 1 ft of
the bottom around all work areas that are in, or adjacent to, surface waters. b) Use these turbidity barriers throughout construction to control erosion and
siltation and ensure that turbidity levels within the project area do not exceed background conditions.
c) Position turbidity barriers in a way that does not block species’ entry to or exit from designated critical habitat.
d) Monitor and maintain turbidity barriers in place until the authorized work has been completed and the water quality in the project area has returned to background conditions.
e) In the range of ESA-listed corals (St. Lucie Inlet, Martin County south to the Dry Tortugas and the U.S. Caribbean) and Johnson’s seagrass (Turkey Creek/Palm
Bay south to central Biscayne Bay in the lagoon systems on the east coast of Florida): i) Projects that include upland earth moving (e.g., grading to install a building or
parking lot associated with a dock and seawall project), must install sediment control barriers to prevent any upland sediments from reaching estuarine or marine waters.
ii) The turbidity curtain requirement cannot be waived for any project that moves or removes sediment (e.g., dredging, auger to create a pile, trenching to install a cableline). If turbidity curtains are not feasible in an area based on site conditions such as water current, high wave action, or stormy conditions, the project must undergo individual Section 7 consultation and is not covered under this Programmatic Opinion.
5) (AP.11.) Entanglement: All turbidity curtains and other in-water equipment must be
properly secured with materials that reduce the risk of entanglement of marine species (described below). Turbidity curtains likewise must be made of materials that reduce the risk of entanglement of marine species. a) In-water lines (rope, chain, and cable, including the lines to secure turbidity
curtains) must be stiff, taut, and non-looping. Examples of such lines are heavy metal chains or heavy cables that do not readily loop and tangle. Flexible in-water lines, such as nylon rope or any lines that could loop or tangle, must be enclosed in a plastic or rubber sleeve/tube to add rigidity and prevent the line from looping and tangling. In all instances, no excess line is allowed in the water.
b) Turbidity curtains and other in-water equipment must be placed in a manner that does not entrap species within the construction area or block access for them to navigate around the construction area.
Project Design Criteria (PDCs) Specific to Activity 2 for Pile-Supported Structures and Anchored Buoys
A2.1. Activities covered by this Opinion include the installation, repair, replacement, and
removal of structures as described below: A2.1.1. The pile-supported and anchored structures included in this Opinion are:
docks and piers, boatlifts, mooring piles and dolphin piles associated with docks/piers; ATONs and PATONs; floating docks; pile-supported chickees (i.e., small, back-country, over-water, pile-supported, primitive camping shelters); boardwalks (as long as they are designed and clearly marked to prohibit fishing and vessel mooring); mooring fields and buoys; and other minor pile-supported structures. This does not include structures that support large commercial vessels including ferries, tankers, and cargo ships such as ferry terminals and large ports.
A2.1.2. Pile-supported docks/piers for a single-family residential lot are limited to 4 slips for motorized vessels. Slips for non-motorized vessels (e.g., kayak, canoe, and paddleboard) and associated launching areas do not count toward the total slip number.
A2.1.3. Pile-supported structures for marinas, multi-family facilities (e.g., condo complexes, trailer parks, subdivisions when the homeowners association owns and controls the in-water structures). Docks and piers for multi-family residential properties (e.g., condos, trailer parks, apartment complexes), and marinas are limited to a maximum of 50 total slips (i.e., combination of wet and dry slips for existing plus proposed slips).
A2.1.4. Anchored buoys and temporary pile-supported structures associated with marine events. Upon completion of the event, these structures must be removed and, to the maximum extent practical, the site must be restored to pre-construction elevations. Water depths in the area of marine events must be deep enough to support at least 5 ft of water depth under the keel of a vessel and between the keel of a vessel and ESA-listed coral colonies when transiting to the mooring areas. There is no limit on the number of vessel slips allowed for temporary structures associated marine events such as boat shows.
A2.1.5. Mooring fields are limited to a maximum of 50 motorized vessels (there is no limit on the number of non-motorized vessels).
A2.1.6. All pile-supported structures constructed must comply with PDC 2.17 for Docks or Other Minor Structures Constructed in Florida Under this Opinion (see below).
The following PDCs apply to all the activities described in PDC A2.1 above: A2.2. For commercial, multi-family, or public facilities, and marine events, signs must be
posted in a visible location(s), alerting users of listed species in the area susceptible to vessel strikes and hook-and-line captures. The most current version of the signs that must be downloaded and sign installation guidance are available at: (http://sero.nmfs.noaa.gov/protected_resources/section_7/protected_species_educational_signs/index.html). The signs required to be posted by area are stated below:
A2.2.1. All projects in Florida shall use the Save Sea Turtle, Sawfish, and Dolphin sign. These signs shall include contact information to the sea turtle and marine
mammal stranding networks and smalltooth sawfish encounter database. A2.2.2. Projects within the North Atlantic right whale educational sign zone (as
defined in Section 2.1.1.4) shall post the Help Protect North Atlantic Right Whales sign.
A2.2.3. On the east coast of Florida, projects located within the St. John’s River and those occurring north of the St. Johns River to the Florida-Georgia line shall post the Report Sturgeon sign. On the west coast of Florida, projects occurring from the Cedar Key, Florida north to the Florida-Alabama line.
A2.2.4. We are still developing the signs to be used in the U.S. Caribbean. Once developed, those signs will be included at the website above.
A2.3. For commercial, multi-family, or public facilities, monofilament recycling bins must be
provided at the docking facility to reduce the risk of turtle or sawfish entanglement in, or ingestion of, marine debris. Monofilament recycling bins must: A2.3.1. Be constructed and labeled according to the instructions
provided at http://mrrp.myfwc.com. A2.3.2. Be maintained in working order and emptied frequently (according to
http://mrrp.myfwc.com standards) so that they do not overflow.
A2.4. For any dock project (new construction, repair, or replacement) at a private residence located within 11 nautical miles of North Atlantic right whale critical habitat (as measured in a radius from the center of the nearest inlet to open ocean and described in Section 2.1.1.4), the property owner will be provided a handout with their USACE permit describing the presence of North Atlantic right whales in the area and the Federal regulations governing the approach to North Atlantic right whales (Appendix C).
A2.5. ATONs and PATONs must be approved by and installed in accordance with the
requirements of the USCG (see 33 CFR, chapter I, subchapter C, part 66 and RHA Section 10 and any other pertinent requirements).
A2.6. Chickees must be less than 500 ft² and support no more than 2 slips.
A2.7. No activities associated with municipal or commercial fishing piers are covered
under this Opinion.
A2.8. Docks installed within visible distance of ocean beaches are required to comply with turtle-friendly lighting, if lighting is necessary to the project. Turtle-friendly lighting is explained and examples are provided on the Florida Fish and Wildlife Conservation Commission website: http://myfwc.com/wildlifehabitats/managed/sea-turtles/lighting/
A2.9. Project construction will take place from uplands or from floating equipment (e.g.,
barge); prop or wheel-washing is prohibited.
Additional PDCs for Activity 2 applicable in Critical Habitat
A2.10. Acropora critical habitat and the U.S. Caribbean: This Opinion does not cover new and expanded pile-supported structures in Acropora critical habitat where the essential features are present. The distance from ATONs to ESA-listed corals and Acropora critical habitat shall ensure there are no impacts to the corals or the essential feature of Acropora critical habitat from the movement of buoys and tackle. The appropriate distance shall be based on the size of the anchor chain or other tackle to be installed to secure the buoy to its anchor, particularly when the design of the ATON does not prohibit contact of tackle with the marine bottom. In all cases, buoy tackle will include flotation to ensure there is no contact between the anchor chain or line and the marine bottom.
A2.11. Gulf sturgeon critical habitat: Additional noise restrictions are required for pile and sheet
pile installation in the Gulf sturgeon critical habitat migratory restriction zones defined in Section 2.1.1.2. The noise restrictions are described in that section.
A2.12. Smalltooth sawfish critical habitat: This Opinion does not cover activities occurring in areas
identified as smalltooth sawfish limited exclusion zones defined in Section 2.1.1.1.
A2.13. North Atlantic right whale critical habitat: This Opinion does not cover installation of anchored ATONs and permanent buoys in North Atlantic right whale critical habitat; temporary buoys for marine events are allowed in North Atlantic right whale critical habitat.
A2.14. Johnson’s seagrass critical habitat: This Opinion does not cover new marinas or multi-
family facilities in Johnson’s seagrass critical habitat. Repair, replacement, and reconfiguration of existing marinas or multi-family facilities may be covered if it (1) occurs within same overall footprint (out to the perimeter of the facility, including the outer limits of the structure and permitted mooring locations), (2) does not increase the total aerial extent (i.e., area of coverage from the dock structures) of the existing facility, and (3) does not affect Johnson’s seagrass. Mooring fields are allowed in Johnson’s seagrass critical habitat and within the range of Johnson’s seagrass so long as they occur in waters deeper than -13 ft (-4 m).
A2.15. NWA DPS of loggerhead sea turtle critical habitat: ATONs (pile-supported and anchored
buoys) are allowed in nearshore reproductive habitat of the NWA DPS of loggerhead sea turtles under this Opinion. No other pile-supported structures are allowed in nearshore reproductive habitat under this Opinion.
A2.16. U.S. Caribbean sea turtle critical habitat (hawksbill, leatherback, and the NA DPS of green
sea turtle critical habitat): ATONs (pile-supported and anchored buoys) are allowed near sea turtle nesting beaches under this Opinion. No other pile-supported structures are allowed near sea turtle nesting beaches under this Opinion.
ATTACHMENT V
STANDARD MANATEE CONDITIONS FOR IN-WATER WORK 2011
The permittee shall comply with the following conditions intended to protect manatees from direct project effects:
a. All personnel associated with the project shall be instructed about the presence of manatees and manatee speed zones, and the need to avoid collisions with and injury to manatees. The permittee shall advise all construction personnel that there are civil and criminal penalties for harming, harassing, or killing manatees which are protected under the Marine Mammal Protection Act, the Endangered Species Act, and the Florida Manatee Sanctuary Act.
b. All vessels associated with the construction project shall operate at "Idle Speed/No Wake” at all times while in the immediate area and while in water where the draft of the vessel provides less than a four-foot clearance from the bottom. All vessels will follow routes of deep water whenever possible.
c. Siltation or turbidity barriers shall be made of material in which manatees cannot become entangled, shall be properly secured, and shall be regularly monitored to avoid manatee entanglement or entrapment. Barriers must not impede manatee movement.
d. All on-site project personnel are responsible for observing water-related activities for the presence of manatee(s). All in-water operations, including vessels, must be shutdown if a manatee(s) comes within 50 feet of the operation. Activities will not resume until the manatee(s) has moved beyond the 50-foot radius of the project operation, or until 30 minutes elapses if the manatee(s) has not reappeared within 50 feet of the operation. Animals must not be herded away or harassed into leaving.
e. Any collision with or injury to a manatee shall be reported immediately to the Florida Fish and Wildlife Conservation Commission (FWC) Hotline at 1-888-404-3922. Collision and/or injury should also be reported to the U.S. Fish and Wildlife Service in Jacksonville (1-904-731-3336) for north Florida or Vero Beach (1-772-562-3909) for south Florida, and to FWC at [email protected]
f. Temporary signs concerning manatees shall be posted prior to and during all in-water project activities. All signs are to be removed by the permittee upon completion of the project. Temporary signs that have already been approved for this use by the FWC must be used. One sign which reads Caution: Boaters must be posted. A second sign measuring at least 8 ½” by 11" explaining the requirements for “Idle Speed/No Wake” and the shut down of in-water operations must be posted in a location prominently visible to all personnel engaged in water-related activities. These signs can be viewed at MyFWC.com/manatee. Questions concerning these signs can be sent to the email address listed above.
CAUTION: MANATEE HABITAT
All project vessels
IDLE SPEED / NO WAKE
When a manatee is within 50 feet of work all in-water activities must
SHUT DOWN
Report any collision with or injury to a manatee:
Wildlife Alert: 1-888-404-FWCC (3922)
cell * FWC or #FWC