REPLACEMENT PARTS 2020

REPLACEMENT PARTS 2020 · 8 NOTE: 1.- All electric defrost units (E) use 4 coil heaters and 2 drain pan heaters. All gas defrost units (G, H) use 2 drain pan heaters. 2.- LSE with

  • Upload
    others

  • View
    2

  • Download
    0

Embed Size (px)

Citation preview

Page 1: REPLACEMENT PARTS 2020 · 8 NOTE: 1.- All electric defrost units (E) use 4 coil heaters and 2 drain pan heaters. All gas defrost units (G, H) use 2 drain pan heaters. 2.- LSE with

REPLACEMENTPARTS 2020

Page 2: REPLACEMENT PARTS 2020 · 8 NOTE: 1.- All electric defrost units (E) use 4 coil heaters and 2 drain pan heaters. All gas defrost units (G, H) use 2 drain pan heaters. 2.- LSE with

REACH-IN COOLERSEC, ED, ES, EW .......................................................................................................................................................................... 3

REACH-IN EUROLINEUS, UD ....................................................................................................................................................................................... 4

COMMERCIAL WALK-IN COOLERSEL, EV, EP ................................................................................................................................................................................. 5LS, LP, LA .................................................................................................................................................................................. 6-8LV .............................................................................................................................................................................................. 9-10

INDUSTRIAL WALK-IN COOLERSEK, EM, EH, EI, EB, EJ, EQ, EX ................................................................................................................................................ 11-12

CONDENSER, FLUID COOLER AND GAS COOLERALL SERIES .............................................................................................................................................................................. 13-16

CONDENSING UNITIC, OC, OV, SC, WC...................................................................................................................................................................... 17-18IL, OL ......................................................................................................................................................................................... 19IE, OE ........................................................................................................................................................................................ 20

GUARDIAN + KE2 DEFROST CONTROLLERS ......................................................................................................................... 21-22

PART DESCRIPTIONMOTORS/FANS .......................................................................................................................................................................... 23MOTORS .................................................................................................................................................................................... 24FAN BLADES ............................................................................................................................................................................. 25FAN DELAYS AND DEFROST TERMINATION THERMOSTATS ................................................................................................ 25TERMINAL BOARDS ................................................................................................................................................................. 25WIRING HARNESS ................................................................................................................................................................... 25FAN GUARDS AND MOTOR MOUNTS ....................................................................................................................................... 26DEFROST HEATERS ................................................................................................................................................................. 26CONDENSER AND CONDENSING UNIT CONTROLS ................................................................................................................ 27TRANSFORMERS ...................................................................................................................................................................... 27TIMERS ..................................................................................................................................................................................... 27CONTACTORS ............................................................................................................................................................................ 28DISCONNECTS .......................................................................................................................................................................... 28CAPACITORS ............................................................................................................................................................................. 28LOCK NUT ................................................................................................................................................................................. 28DRAIN FITTINGS ...................................................................................................................................................................... 28

NOTES ....................................................................................................................................................................................... 29

Table of contents RP-RPLPARTS-2019-00

Page 3: REPLACEMENT PARTS 2020 · 8 NOTE: 1.- All electric defrost units (E) use 4 coil heaters and 2 drain pan heaters. All gas defrost units (G, H) use 2 drain pan heaters. 2.- LSE with

3

SUFFIX -1

120/1/60

SUFFIX -2

240/1/60

NOTE : 1.- Motors are mounted in sheet metal base.2.- Fan guards were changed from black round shape mounted at 45º to grey square guard mounted at 90º.

We recommend replacing all fan guards for uniformity and best performance

MODEL

NOTE : 1.- These heaters are obsolete and must be replaced by current models (serial # 96090001 to NOW).2.- Available for 120/1/60 models only.

NOTE : 1.- Fan delay is obsolete and must be replaced by RTH-0002. When replacing RTH-0001 with RTH-0002, interchange black and brown wire to defrost termination, black to common

NOTE : 1.- DFK-1 includes RHW-4008, RHW-4009, RHW-2010.

MOTOR (1) FAN BLADE FAN GUARD (2)

ALL MODELS ALL MODELS EC, ED, ES

RMT-0001 RFN-0010 RGR-0040

RMT-0002

EDEOBSOLETE 100, 130, 150, 180 (2) REH-0021 (1)

ELECTRIC DEFROST HEATERCURRENT OLD SERIAL # 94010001 to 96089999 SERIAL #96090001 to NOW

(2) REH-0022 (1) (2)

(2) REH-0041OBSOLETE 230, 280, 330 (2) REH-0031 (1) (2) REH-0051

182 180, 181 (2) REH-0042 (1)

(1) REH-0051 (2)

152 150, 151 (2) REH-0032 (1) (2) (1) REH-0061 (2)102, 132 100, 101, 130, 131

SERIAL #04010001 to NOW

ESE

452, 552 450, 451, 550, 551 (2) REH-0062 (1)

(2) REH-0041232, 282, 332 230, 231, 280, 281, 330, 331 (2) REH-0052 (1) (2) REH-0051

RTH-0001 (1) RTH-0002 RTH-0004

DRAIN FITTING KIT TERMINAL BOARD

(2) REH-0061

FAN DELAY DEFROST TERMINATION THERMOSTAT HEATER SAFETYSERIAL # 94010001 to 99010000 SER.# 99010001 to 03129999

ALL MODELS ES(E)DFK-1 (1) REM-0004

REACH-IN COOLERS EC,ED,ES,EW

Page 4: REPLACEMENT PARTS 2020 · 8 NOTE: 1.- All electric defrost units (E) use 4 coil heaters and 2 drain pan heaters. All gas defrost units (G, H) use 2 drain pan heaters. 2.- LSE with

4

REACH-IN EUROLINE US,UD

NOTES : 1.- DFK-1 includes RHW-4008, RHW-4009, RHW-2010. 2.- Motor for UD includes RHW-1999 (2) 3.- SEK-1 includes RMT-5005,RMT-5009,RMT-5010 (to use with Elco brand motors RMT-0100,0101,0102,0103,0107,0108)

SEK-1A includes RMT-5003, RMT-5005, RMT-5009 (to use with EBM brand motors RMT-0100, 0101, 0102, 0103).4.- Since january 2016 supersedes RMT-0103 (RMT-0103 was CE approved only)5.- Since july 2010 supersedes RMT-01006.- Since july 2010 supersedes RMT-01027.- Since january 2014 supersedes RFN-0032

USFAN BLADE

UD330

120/1/50-60SUFFIX -2 RMT-0108 (6)

AND RMT-0104AND RMT-0104

RFN-0015 (7)

DFK-1 (1)

RFN-0033 RFN-0034 RFN-0031

RGR-0079

FAN GUARD

UD230 to 330

UD130 to 180 UD230, 280

US

AND RMT-0104RMT-0107 (5)

AND RMT-0104RMT-0101

RMT-0108 (4)

SHAFT END KITUD

US

RGR-0040

UD230 to 330UD090 to 180

RGR-0078

DRAIN FITTING KITALL MODELS

SEK-1 and SEK-1A (3)

MOTOR

RFN-0010

240/1/50-60

UD090 to 180 (2)

RMT-0001

RMT-0002

UD090, 110

MODELSUFFIX -1

Page 5: REPLACEMENT PARTS 2020 · 8 NOTE: 1.- All electric defrost units (E) use 4 coil heaters and 2 drain pan heaters. All gas defrost units (G, H) use 2 drain pan heaters. 2.- LSE with

5

COMMERCIAL WALK-IN COOLERS EL,EP,EV

NOTE : 1.- Motors are mounted in sheet metal base.2.- Fan guards were changed from black to grey. We recommend replacing all fan guards for uniformity and best performance.3.- When replacing the fan blade of the old models, the fan guard must be changed also.

NOTE : 1.- All electric defrost units (E) use 4 coil heaters and 2 drain pan heaters. All gas defrost units (G) (H) use 2 drain pan heaters.

2.- Since june 2015, heaters series REH-1XXX supersedes heaters series REH-0XXX

NOTE : 1.- Since january 2004, supersedes RTH 0002.2.- New component since january 2004.3.- Since september 2017, supersedes RTH-0008

NOTE : 1.- DFK-2 includes RHW-4007, RHW-2011, RFT-5135.

REH-1070

N/A

N/A

REH-1080

REH-1085

REH-1090

REH-1097

REH-1100

REH-1010

REH-1020

REH-1040

REH-1050

3001

1501

1001

REH-1060

0801

24011801

EP, EVRFN-0021

UPFLOW

RTH-0002

N/A

EDEFROST CONTROL

DEFROST TERMINATION

FAN DELAY RTH-0003

MOTOR (1)

G & HR & T

ALL MODELSREM-0004

FAN GUARD (2)

ALL MODELS

RGR-0080

FAN BLADE (3)

EL

DFK-2 (1)

DRAIN FITTING KITALL MODELS

N/A

HEATER SAFETY

PAN HEATER SAFETY

TERMINAL BOARD

RTH-0002

RTH-0004 (1)

(EL) RTH-0002(EP,EV) RTH-0060 (3)

N/A N/A

3501 3601

2601 2601

3121 3121

1321

ALL MODELS

12011561 1561

3501

2081 2081

0781 0781

1041 1041

0901 0901

1321

ALL MODELS

RMT-0011SUFFIX-1120/1/60

MODEL (1)

EVE(G)(H)

RFN-0020SUFFIX-2240/1/60

RMT-0012

0521 0521

ELE(G)(H)0441

EPE(G)(H)

ELECTRIC DEFROST HEATER (2)

RFN-0020DOWN FLOW

0601

SUFFIX 8 & 9SUFFIX 1, 2 & 5

REH-1030

REW-0040REW-0030REW-0020

ALL MODELSWIRING HARNESS

RTH-0004 (2)

Page 6: REPLACEMENT PARTS 2020 · 8 NOTE: 1.- All electric defrost units (E) use 4 coil heaters and 2 drain pan heaters. All gas defrost units (G, H) use 2 drain pan heaters. 2.- LSE with

6

COMMERCIAL WALK-IN COOLERS LS,LP,LA

LSMODELS BEFORE

APRIL 2009MODELS SINCE

APRIL 2009

STANDARD MOTOR

OPT. ECM MOTOR (9) RGR-0085 (1) RGR-0086

RGR-0084 (2)

NOTE: 1. Standard plastic guard

2.- Optional steel wire guard

1 OR 2 SPEEDS

RMT-0073 (3)

VARIABLE SPEED

RMT-0073 (3)

AND RMT-0074

STANDARD MOTOR

VARIABLE SPEED

RMT-0109

RMT-0105

1 OR 2 SPEEDS

RMT-0072 (2) (9)

VARIABLE SPEED (9)

RMT-0072 (2)

AND RMT-0074

VARIABLE SPEED

RMT-0110

RMT-0106

1 OR 2 SPEEDS

RMT-0073 (3) (9)

VARIABLE SPEED (9)

RMT-0073 (3)

AND RMT-0074

NOTE: 1.- Motors included four RHW 1999

2.- Since january 2015, supersedes RMT-0070

3.- Since january 2015, supersedes RMT-0071

4.- LP99996-1 (standard up flow) includes RMT-0105, RFN-0082 and sheet metal base.

LP99996-2 (standard up flow) includes RMT-0106, RFN-0082 and sheet metal base.

LP99996-1R (optional down flow) includes RMT-0105, RFN-0083 and sheet metal base.

LP99996-2R (optional down flow) includes RMT-0106, RFN-0083 and sheet metal base.

5.- Since april 2009, supersedes RMT-0004

6.- Since april 2009, supersedes RMT-0005

7.- Since july 2010, supersedes RMT-0100

8.- Since july 2010, supersedes RMT-0102

9.- These motors must be programmed at the factory.

FAN GUARDLP, LA

MOTORLS

RMT-0106

MODELS SINCE APRIL 2009ELECTRICAL

SUPPLY

MODELS BEFORE

APRIL 2009RGR-0085 (1)

RGR-0084 (2)

SUFFIX -2 240/1/50-60

RMT-0105

RMT-0005 (1)

1 OR 2 SPEEDS

RMT-0072 (2)

VARIABLE SPEED

RMT-0072 (2)

AND RMT-0074

SUFFIX -1 120/1/50-60 RMT-0004 (1)

SUFFIX -2 240/1/50-60

SUFFIX -1 120/1/50-60

STANDARD UP FLOW LP99996-1 (4) (5)

OPTIONAL DOWN FLOW LP99996-1R (4) (5)

STANDARD UP FLOW LP99996-2 (4) (6)

OPTIONAL DOWN FLO LP99996-2R (4) (6)

MODELS BEFORE APRIL 2009

MOTORLP, LA

MODELS SINCE APRIL 2009

MODELS NO. OPTIONAL ELECTRONIC MOTOR

ELECTRICAL SUPPLY

LPA 0601 to 2001 and 2401 LPE(G,H) 0571 to 1901 and 2301

LAA 0601 to 2801 LAE(G,H) 0571 to 2701

LPA 2101 and 2801 to 4201 LPE(G,H) 2001 and 2701 to 4001

LAA 3001 to 4601 LAE(G,H) 2861 to 4381

LPA 0601 to 2001 and 2401 LPE(G,H) 0571 to 1901 and 2301

LAA 0601 to 2801 LAE(G,H) 0571 to 2701

LPA 2101 and 2801 to 4201 LPE(G,H) 2001 and 2701 to 4001

LAA 3001 to 4601 LAE(G,H) 2861 to 4381

RMT-0107 (7)

RMT-0108 (8)

Page 7: REPLACEMENT PARTS 2020 · 8 NOTE: 1.- All electric defrost units (E) use 4 coil heaters and 2 drain pan heaters. All gas defrost units (G, H) use 2 drain pan heaters. 2.- LSE with

7

COMMERCIAL WALK-IN COOLERS LS,LP,LA

MODELS BEFORE APRIL 2009

MODELS SINCE APRIL 2009

MODELS BEFORE APRIL 2009

STANDARD MOTOROPTIONAL

ELECTRONIC MOTOR

MODELS BEFORE APRIL 2009

MODELS SINCE APRIL 2009

MODELS BEFORE APRIL 2009

STANDARD MOTOROPTIONAL

ELECTRONIC MOTOR

NOTE: 1.- Since january 2015 supersedes RFN-0032

FAN BLADELS LP, LA

MODELS SINCE APRIL 2009

RFN-0023 RFN-0083

RFN-0022 (UP FLOW)

OR RFN-0023

(DOWN FLOW)

MODELS NO.

LPA 0601 to 2001 and 2401 LPE(G,H) 0571 to 1901 and 2301

LAA 0601 to 2801 LAE(G,H) 0571 to 2701

RFN-0015 (1) (UP FLOW) OR

RFN-0084 (DOWN FLOW)

LPA 2101 and 2801 to 4201 LPE(G,H) 2001 and 2701 to 4001

LAA 3001 to 4601 LAE(G,H) 2861 to 4381

RFN-0082 (UP FLOW) OR

RFN-0083 (DOWN FLOW)

MOTOR MOUNTLS LP, LA

MODELS SINCE APRIL 2009

LS005-01 RGR-0130 LP006-01

MODELS NO.

LPA 0601 to 2001 and 2401 LPE(G,H) 0571 to 1901 and 2301

LAA 0601 to 2801 LAE(G,H) 0571 to 2701

LP118-01 (1 REQ.) AND

LP119-01 (2 REQ.)

LPA 2101 and 2801 to 4201 LPE(G,H) 2001 and 2701 to 4001

LAA 3001 to 4601 LAE(G,H) 2861 to 4381

RGR-0130

Page 8: REPLACEMENT PARTS 2020 · 8 NOTE: 1.- All electric defrost units (E) use 4 coil heaters and 2 drain pan heaters. All gas defrost units (G, H) use 2 drain pan heaters. 2.- LSE with

8

NOTE: 1.- All electric defrost units (E) use 4 coil heaters and 2 drain pan heaters. All gas defrost units (G, H) use 2 drain pan heaters.

2.- LSE with a 1 at the end of the model number (ex. LSE 043 1) are made for suffix 1,2 and 5 only.3.- Since june 2015, heaters series REH-1XXX supersedes heaters series REH-0XXX

R & T E R & T E

RTH-0003 RTH-0203

N/A N/A N/A N/A

N/A RTH-0004 (2) N/A RTH-0004

NOTE: 1.- Since january 2004, supersedes RTH 0002. 2.- New component since january 2004. 3.- Since september 2017, supersedes RTH-0008

LS

NOTE: 1.- DFK-2 includes RHW 4007, RHW 2011, RFT 5135

NOTE 1.- SEK-1 includes RMT-5005,RMT,5009,RMT-5010 (to use with Elco brand motors RMT-0100,0101,0102,0103,0107,0108) SEK-1A includes RMT-5003,RMT,5005,RMT-5009 (to use with EBM brand motors RMT-0100,0101,0102,0103)

2.- SEK-2 includes RMT-5006,RMT-5007,RMT-5008 (to use with RMT-0004,0005)

N/A

LP, LA BEFORE APRIL 2009

FAN DELAY

DRAIN FITTING KIT

REW-0020

ALL MODELS

SHAFT END KIT WIRING HARNESS

TERMINAL BOARD

REW-0040SEK-2 (2)

SEK-1 and SEK-1A (1)

ALL MODELS ALL MODELS

PAN HEATER SAFETY

HEATER SAFETY

REW-0030

DFK-2 (1) REM-0004

0951, 1151, 1800, 2100, 2001

REH-1090

N/A

(LS) RTH-0202 (1)

(LP, LA) RTH-0060 (3)

RTH-0004

REH-1100REH-1070

REH-1097

2301, 4200, 4001

RTH-0004 (1)

2201, 2400, 2401

0431, 0500, 0521, 0600, 0621

0721, 0800, 0881, 1000, 1031

1200, 1241

0571, 0650, 0760

REH-1010

REH-1020

REH-1030

REH-10401331, 1500, 1521, 1800, 1801

1800, 1701

N/A0600, 0700

N/A

REH-1080

REH-1085

REH-1050

0571, 0950, 1200

1200, 1141, 1500, 1431

1521, 2800, 2701

3000, 3001

3600, 3701

REH-1060

G & H

(LS) RTH-0002 (LP, LA) RTH-0060 (3)

2701, 3000, 3431, 4500, 4381

MODELS SINCE APRIL 2009MODELS BEFORE APRIL 2009

RTH-0202 (1)

RTH-0202 (1)

0671, 0761, 1400

G & H

RTH-0002RTH-0002

0721, 0900. 0901

1901, 3500, 3341 2301, 2700, 2861, 3800, 4001

DEFROST CONTROL

ALL MODELS

DEFROST TERMINATION

ELECTRIC DEFROST HEATER (3)

MODELS (1) SUFFIX 1, 2 & 5

SUFFIX 8 & 9LSE (2) LPE (G,H) LAE (G,H)

COMMERCIAL WALK-IN COOLERS LS,LP,LA

Page 9: REPLACEMENT PARTS 2020 · 8 NOTE: 1.- All electric defrost units (E) use 4 coil heaters and 2 drain pan heaters. All gas defrost units (G, H) use 2 drain pan heaters. 2.- LSE with

9

RMT-0012 (6) (7) N/A N/A

N/A N/A

NOTE : 1.- Motors are mounted in sheet metal base. 6.- Also 240/1/50 and 240/3/502.- Since july 2010 RMT-0107 supersedes RMT-0100 7.-Since June 2009, supersedes RMT00053.- Since july 2010 RMT-0108 supersedes RMT-0102 8.-Since january 2006, supersedes RMT-00164.- Also 120/1/50 9.- These motors must be programmed at the factory5.- Since june 2009, supersedes RMT-0004

NOTE : 1.- Since June 2009, supersedes RFN-00362.- Since June 2009, supersedes RFN-0022 on LV 1500 and RFN-0026 on LV 19003.- Since january 2014, supersedes RFN-0032

VARIABLE SPEED (9)

RMT-0073 AND RMT-0074

N/A

N/A

N/A1 OR 2 SPEEDS (9)

RMT-00721500, 1900 VARIABLE SPEED (9)

RMT-0072 AND RMT-0074

N/A

3000, 3600 4200

FAN BLADE

N/A

0700 0800, 0900 1500, 1900 2400, 2700

RMT-0018 RMT-0015

N/A N/A

2400, 2700, 3000, 3600, 4200 (1)

RMT-0105 (5)

RMT-0014 RMT-0010 (8)

SUFFIX - 2, - 5

1 OR 2 SPEEDS (9)

RMT-0073

240/1/60 208-240/3/60 600/3/60 480/3/60

AND RMT-01040700, 0800, 0900 (1) RMT-0107 (2) RMT-0108 (3) N/A

RFN 0021 (1) RFN 0082 (2) RFN 0028

N/AVARIABLE SPEED RMT-0109

VARIABLE SPEED RMT-0110

N/A

RFN 0029 RFN 0030

1200

MOTOR

MODEL

1500, 1900

SUFFIX - 1 SUFFIX - 2, - 5 SUFFIX - 8 SUFFIX - 9120/1/60

AND RMT-0104 N/A

1200 (1)

RMT-0106 (6) (7) N/A

1200

SUFFIX - 8 SUFFIX - 9120/1/60 240/1/60 208-240/3/60

N/A

480/3/60

RFN-0031 RFN-0015 (3)

0700, 0800, 0900 (1) N/A

2400, 2700, 3000, 3600, 4200 (1)

RMT-0011 (4) (5)

600/3/60

ECM MOTOR TWO SPEED OR VARIABLE SPEED

MODEL SUFFIX - 1

COMMERCIAL WALK-IN COOLERS LV

Page 10: REPLACEMENT PARTS 2020 · 8 NOTE: 1.- All electric defrost units (E) use 4 coil heaters and 2 drain pan heaters. All gas defrost units (G, H) use 2 drain pan heaters. 2.- LSE with

10

NOTE : 1.- All electric defrost units (E) use 4 coil heaters and 2 drain pan heaters. All gas defrost units (G)(H) use 2 drain pan heaters.

2.- Since june 2015, heaters series REH-1XXX supersedes heaters series RMT-0XXX

NOTE : 1.- SEK-1 includes RMT 5006, RMT 5007, RMT 5008 SEK-1A includes RMT 5003, RMT 5005, RMT 5009

2.- SEK-2 includes RMT 5002, RMT 5003, RMT 5006

NOTE : 1.- Since september 2017, supersedes RTH-0008

1.- DFK-2 includes RHW-4007, RHW-2011, RFT-5135

PAN HEATER SAFETY RTH-0004 N/A

HEATER SAFETY N/A RTH-0004

0700, 0800, 0900 1200, 1500, 1900

DEFROST TERMINATION RTH-0002RTH-0002

SEK-1 and SEK-1A (1) SEK-2 (2)

FAN DELAY RTH-0060 (1)

WIRING HARNESS

2700, 3000 REH-1060 REH-1097

4200 REH-1070 REH-1100

DEFROST CONTROL SHAFT END KITALL MODELS

1200, 1500, 1900

3600

REW-0020

1500REH-1050 N/A

ALL MODELS (E, G, H)

1900

REM-0004

2400

ALL MODELS

REH-1030 N/A

DFK-2 (1)

0900REH-1040 N/A

1200

TERMINAL BOARD

0700, 0800

RGR 0085

ELECTRIC DEFROST HEATER (2)

DRAIN FITTING KIT

MODEL (1) SUFFIX 1, 2 & 5 SUFFIX 8 & 9

REH-1050 REH-1090

G & H E

RGR 0090

1500, 1900

RGR-0130

FAN GUARD

MOTOR MOUNT

0700, 0800, 0900, 1200 1500, 1900 2400, 2700, 30003600, 4200

RGR 0078

COMMERCIAL WALK-IN COOLERS LV

Page 11: REPLACEMENT PARTS 2020 · 8 NOTE: 1.- All electric defrost units (E) use 4 coil heaters and 2 drain pan heaters. All gas defrost units (G, H) use 2 drain pan heaters. 2.- LSE with

11

NOTE: 1.- Since january 2006, supersedes RMT-0016 5.- Since october 2008, supersedes RMT-00522.- Since october 2008, supersedes RMT-0041 6.- These motors must be programmed at the factory3.- Since october 2008, supersedes RMT-0042 7.- These motors need 24V. Power4.- Since october 2008, supersedes RMT-0051

NOTE : 1.- Since may 14, 2009 supersedes RGR-0140 2.- Since may 14, 2009 supersedes RGR-0160 3.- Since may 14, 2009 supersedes RGR-0180

NOTE : 1.- For units manufactured before March 2000 we recommend replacing the existing motor with the current EK series motor

2.- Units with obsolete motor RMT-0041 and RMT-0042 use fan blade RFN-0050

3.- Units with obsolete motor RMT-0051 and RMT-0052 use fan blade RFN-0051

NOTE : 1.- Standard plastic guard2.- Optional steel wire guard

1 OR 2 SPEEDS RMT-0082 (6) (7)

RGR-0182 (3)EK007-01AND

1 OR 2 SPEEDS RMT-0080 (6) (7)

VARIABLE SPEED RMT-0080(6)

EK008-01 REC-0003

MOTOR MOUNTEK

ECM MOTOREK EM

N/A

VARIABLE SPEED RMT-0082(6)

REC-0006 N/R

REC-0004

N/R

MOTOR CAPACITOREH, EI, EB

RMT-0022

EK EM

EK

RGR-0090 (1)

EM EH, EI, EB

REC-0006

RFN-0040

RFN-0041

EH

EH

RMT-0091 (3)

SUFFIX-9

RGR-0142 (1)

RGR-0162 (2)

208-240/3/60

480/3/60

N/A

RMT-0090 (2)

SUFFIX-2240/1/60

RMT-0093 (5)

EI, EB

SUFFIX-5

SUFFIX-2240/1/60

SUFFIX-8

EKMODEL

480/3/60SUFFIX-9

MOTOREI, EB

N/A

RMT-0092 (4)

EKMODEL EM

RMT-0031

SUFFIX-9

600/3/60

SUFFIX-8600/3/60

RFN-0091 (3)

RMT-0032

SUFFIX-5

RFN-0090 (2)

MODEL

EM

RGR-0089 (2)RGR-0100 RGR-0120

480/3/60SUFFIX-8

240/1/60

RFN-0030 (1)

SUFFIX-2

FAN BLADE

208-240/3/60

208-240/3/60

RMT-0010 (1)

RMT-0015

FAN GUARD

SUFFIX-5

RMT-0018

EM

600/3/60

MOTOR

MODELSUFFIX-2240/1/60SUFFIX-5

208-240/3/60SUFFIX-9480/3/60SUFFIX-8600/3/60

RFN-0413 575/3/60

EQ EXPRE ASSEMBLED MOTOR, FAN GUARD, FAN BLADE AND

VENTURY PANEL

RFN-0411

RFN-0412

EJMODEL

SUFFIX: (-5)208-240/3/60SUFFIX: (-9)

480/3/60SUFFIX: (-8)

RFN-0421

RFN-0422

RFN-0423

RFN-0401

RFN-0402

RFN-0403

INDUSTRIAL WALK-IN COOLERS EK,EM,EH,EI,EB,EJ,EQ,EX

Page 12: REPLACEMENT PARTS 2020 · 8 NOTE: 1.- All electric defrost units (E) use 4 coil heaters and 2 drain pan heaters. All gas defrost units (G, H) use 2 drain pan heaters. 2.- LSE with

12

NOTE: 1.- Since june 2015, heaters series REH-1XXX supersedes heaters series REH-0XXX

NOTE : 1.- Since january 2004, supersedes RTH 0002.

NOTE : 1.- DFK-2 includes RHW 4007, RHW 2011 & RFT 5135.2.- DFK-3 includes RHW 4012, RHW 4013 & RFT 8002.3.-Since april 2007, DFK-3 supersedes DFK-2

RTH-0060 (5)

5.- Since mai 2020, supersedes RTH-0002 & RTH-0060

222103540042720

18610

35400

EKE1300

4000

15001700

20980

1360016370

3400

42720

906010910

50006000

2900

17160

2573031460

22210

EJE EQE EXE

342045305460

2000

136001637025730

1620020400

18610

2200

6840

10910

24000 2720031460

12000

1400018000

20980

44005400

17160

34204530

13600

6800 54606000

80009600

EIE EBE EFE

880010800

68409060

HEATER SAFETY

N/A

11600

EME

200024002900

40004800

96008700

EHE

EK SERIES

PART No.TERMINAL BOARD

A, R, T

EM (3) , EH, EI, EB, EF SERIESDRAIN FITTING KIT

E

N/A

REH-1100

REH-1040

REH-1060 REH-1097

ELECTRIC DEFROST HEATER (1)

840011100

REH-1050 REH-1090

450056007500

4200

REH-1085

460059007700

SUFFIX 8 & 9MODEL SUFFIX 2 & 5

N/AREH-1020

40004800

2.- New component since january 2004 on EH, EI, EB and EF.

DFK-2 (1)

DEFROST TERMINATION

RTH-0004 (2)

FAN DELAYRTH-0060 (3)

DFK-3 (2)

RTH-0004 (1)

N/AN/A

REH-1030 REH-1080

15600

PAN HEATER SAFETY

REM-0004REM-0003

REH-1075

MODELG & H

2000

RTH-0060 (4)

ALL MODELS

930011600

REM-0004

REH-1070

REH-1110

15400

53006900

85001050013900

DEFROST CONTROL

28003700

5800

7200

4.- Since september 2017, supersedes RTH-0002

23900

32200

1600021200

28600

17700

R & T

3.- Since september 2017, supersedes RTH-0008

E

INDUSTRIAL WALK-IN COOLERS EK,EM,EH,EI,EB,EJ,EQ,EX

Page 13: REPLACEMENT PARTS 2020 · 8 NOTE: 1.- All electric defrost units (E) use 4 coil heaters and 2 drain pan heaters. All gas defrost units (G, H) use 2 drain pan heaters. 2.- LSE with

13

CONDENSER,FLUID COOLER AND GAS COOLER

OLD MODELS CVD, CV8, CVVNEW MODELS CZR, CVR, CVW, CVX, CBR, CBW, CBXGAS COOLER TZD, TVD, TVW, TBD, TBWOLD MODELS

NEW MODELS FVD, FVV, FZD, FBD, FBVHEAT RECLAIM PZD

NOTE: 1.- Requires Run Capacitor model REC 0003.2.- Requires Run Capacitor model REC 0004.3.- Since October 2008 on CLD, CL8, CLV, FLD, FLV Models, supersedes RMT-0041. 4.- Since October 2008 on CLD, CL8, CLV, FLD, FLV Models, supersedes RMT-0042. 5.- Since October 2008 on CID, CI8, CIV, FID, FIV Models, supersedes RMT-0051. 6.- Since October 2008 on CID, CI8, CIV, FID, FIV Models, supersedes RMT-0052. 7.- Since Mid of 2016 , RFN-0401, 0402 and 0403 supersedes RFN-0101, 0102 and 01038.- Since End of 2016 , RFN-0421, 0422 and 0423 supersedes RFN-0121, 0122 and 01239.- Since Mid-September 2016 , RFN-0413 supersedes RFN-0113

10.- If the fan ventury to be replaced is made of steel, you will need an adapter to install the replacement fan. (Consult RefPlus sales departement)11.- Since july 2018 , RFN-0412 supersedes RFN-0112

CCD, CCR FCD, HCD TCD, PCD

NOTE: 1.- Since May 14 2009 supersedes RGR 01402.- Since May 14 2009 supersedes RGR 01603.- Since May 14 2009 supersedes RGR 0180

HCD, HMD, PCD, PMD

FLUID COOLERS

CCD, CMD, CQD, CQ8, CLD, CL8, CLV, CHD, CH8, CID, CI8, CIVCCR, CMR, CLR, CLW, CLX, CNR, CNW, CNXTCD, TMD, TLD, TLW, TND, TNWFID, FIVFCD, FMD, FLD, FLV, FND, FNV

CONDENSERS

CLD, CL8, CLV, CLR, CLW, CLX,

FLD, FLV TLD, TLW

CID, CI8 CIV, CNR

CNW, CNX FID, FIV

FND, FNV TND, TNW

CHD, CH8 CQD, CQ8

RFN-0423 (8)(10)

RFN-0111

RFN-0412 (10)(11)

RFN-0413 (9)(10)

RMT-0090 (3) RMT-0092 (5)

MOTOR MOUNT

CZR, FZD TZD, PZD

CBR, CBW CBX, FBD, FBV TBD,

TBW

RMT-0020RMT-0093 (6)RMT-0091 (4)SUFFIX: (-8)600/3/60

CLD, CL8, CLV, CLR, CLW, CLX, FLD, FLV

CID, CI8 CIV, CNR

CNW, CNX FID, FIV

FND, FNV TND, TNW

RMT-0022 (2)

RMT-0031

RMT-0021 (1)SUFFIX: (-2)240/1/60

SUFFIX: (-5)208-240/3/60

MODEL CMD, CMR, FMD, HMD

MODELCCD, CCR FCD, HCD TCD, PCD

208-240/3/60SUFFIX: (-5)

N/A

600/3/60

SUFFIX: (-9)N/A

240/1/60SUFFIX: (-2)

RMT-0032

CHD, CH8

CVD, CV8, CVV, CVR, CVW, CVX, FVD, FVV

RGR-0162 (2)SUFFIX: (-9)480/3/60

SUFFIX: (-8)

RGR-0142 (1)

CVD, CV8, CVV, CVR, CVW, CVX,

FVD, FVV TVD, TVW

RFN-0401 (7)(10)

RFN-0402 (7)(10)

N/A

N/A

RFN-0403 (7)(10)RMT-0062

RGR-0182 (3)

CQD, CQ8

RMT-0019

MOTOR

CZR, FZD TZD, PZD

CBR, CBW CBX, FBD, FBV TBD,

TBW

N/A

RFN-0421 (8)(10)

RFN-0422 (8)(10)480/3/60

RMT-0061

PRE ASSEMBLED MOTOR, FAN GUARD, FAN BLADE AND VENTURY PANEL

CMD, CMR TMD, FMD HMD, PMD

Page 14: REPLACEMENT PARTS 2020 · 8 NOTE: 1.- All electric defrost units (E) use 4 coil heaters and 2 drain pan heaters. All gas defrost units (G, H) use 2 drain pan heaters. 2.- LSE with

14

OLD MODELS CVD, CV8, CVVNEW MODELS CZR, CVR, CVW, CVX, CBR, CBW, CBXGAS COOLER TZD, TVD, TVW, TBD, TBWOLD MODELS

NEW MODELS FVD, FVV, FZD, FBD, FBVHEAT RECLAIM PZD

CCD, CCR FCD, HCD TCD, PCD

NOTE: 1.- On CLD, CL8, CLV, FLD, FLV models with obsolete motor RMT-0041 and RMT-0042 use fan blade RFN-00502.- On CID, CI8, CIV, FID, FIV models with obsolete motor RMT-0051 and RMT-0052 use fan blade RFN-00513.- This fan have to be mount with motor mount RGR-0182 and motor RMT-0090 or RMT-00914.- This fan have to be mount with motor mount RGR-0182 and motor RMT-0092 or RMT-0093

CCD, CCR FCD, HCD TCD,PCD

HCD, HMD, PCD, PMD

CCD, CMD, CQD, CQ8, CLD, CL8, CLV, CHD, CH8, CID, CI8, CIVCCR, CMR, CLR, CLW, CLX, CNR, CNW, CNXTCD, TMD, TLD, TLW, TND, TNW

FLUID COOLERSFID, FIVFCD, FMD, FLD, FLV, FND, FNV

CONDENSERS

FAN GUARD

MODELCMD, CMR TMD, FMD HMD, PMD

CLD, CL8, CLV, CLR, CLW, CLX,

FLD, FLV TLD, TLW

RFN-0090 (1) (3)

RFN-0091 (2) (4)

RFN-0052

SUFFIX: (-8)

CBR, CBW CBX, FBD, FBV TBD,

TBW

CQD, CQ8

FAN BLADE

MODELCMD, CMR TMD, FMD HMD, PMD

CLD, CL8, CLV, CLR, CLW, CLX,

FLD, FLV TLD, TLW

CID, CI8, CIV, CNR, CNW,

CNX, FID, FIV, FND, FNV TND, TNW

CHD, CH8 CQD, CQ8

CVD, CV8, CVV, CVR, CVW, CVX,

FVD, FVV TVD, TVW

CZR, FZD TZD, PZD

N/A

CBR, CBW CBX, FBD, FBV TBD,

TBW

SUFFIX: (-2)240/1/60

RFN-0040

SUFFIX: (-5)

N/A

RFN-0041

600/3/60

SUFFIX: (-2)240/1/60

CVD, CV8, CVV, CVR, CVW, CVX,

FVD, FVV TVD, TVW

CZR, FZD TZD, PZD

N/A

208-240/3/60SUFFIX: (-9)

480/3/60

CID, CI8, CIV, CNR, CNW,

CNX, FID, FIV, FND, FNV TND, TNW

CHD, CH8

SUFFIX: (-5)

N/A

208-240/3/60SUFFIX-9480/3/60

SUFFIX-8600/3/60

RGR-0100 N/A

690 PSIG MWPREP-0050REP-0061

CONDENSER FAN CYCLINGBY GAS PRESSURE

RTH-0022

BY AIR TEMPERATURE

RGR-0100

RTH-0037

N/A

475 PSIG MWP

FLUID COOLER FAN CYCLING

RTH-0048RTH-0049

RGR-0120

FLUID COOLER FAN CYCLING

OBSOLETE COMPONENTS

RTH-0034

RTH-0046RTH-0047

RTH-0023RTH-0024RTH-0025RTH-0035

CONDENSER,FLUID COOLER AND GAS COOLER

Page 15: REPLACEMENT PARTS 2020 · 8 NOTE: 1.- All electric defrost units (E) use 4 coil heaters and 2 drain pan heaters. All gas defrost units (G, H) use 2 drain pan heaters. 2.- LSE with

15

OLD MODELS CVD, CV8, CVVNEW MODELS CZR, CVR, CVW, CVX, CBR, CBW, CBXGAS COOLER TZD, TVD, TVW, TBD, TBWOLD MODELS

NEW MODELS FVD, FVV, FZD, FBD, FBVHEAT RECLAIM PZD

24V

CBR, CBW CBX, FBD FBV, TBD

TBW

SPEED CONTROL

208-230 VOLTS

SPEED CONTROL

460-575 VOLTS

TRANDUCERR22, R134

R404, R407

TRANDUCERR-410A

NOTE : 1.- Requires run capacitor model REC 0006.2.- Requires run capacitor model REC 0008.3.- 600 volts units requires autotransformer RET-02144.- 600 volts units requires autotransformer RET-0280

7.- Since febuary 2010 supersedes REP-0102 and REP-0103

HCD, HMD, PCD, PMD

RFN-0407 (9)

RFN-0408 (10)

RFN-0408 (4)(10)

RFN-0407 (9)

RFN-0408 (10)

RFN-0408 (4)(10)

RFN-0427

120V 24V

CCD, CMD, CQD, CQ8, CLD, CL8, CLV, CHD, CH8, CID, CI8, CIVCCR, CMR, CLR, CLW, CLX, CNR, CNW, CNXTCD, TMD, TLD, TLW, TND, TNW

FLUID COOLERSFID, FIVFCD, FMD, FLD, FLV, FND, FNV

PRE ASSEMBLED MOTOR, FAN GUARD AND FAN BLADE

UNIT CCD, CCR FCD, HCD TCD, PCD

CMD, CMR TMD, FMD HMD, PMD

CLD, CL8 CLV, CLR CLW, CLX FLD, FLV TLD, TLW

CID, CI8 CIV, CNR

CNW, CNX FID, FIV

FND, FNV TND, TNW

CHD, CH8 CQD, CQ8

RMT-0013 (1)

(3)

8.- Use two transducers for dual input

RET-0100

RET-0229(250VA)

BY LIQUIDTEMPERATURE

FAN BLADE

SUFFIX: (-5)208-240/3/60

RFN-0040 RFN-0053

RGR-0142 (5)

TRANSFORMER

RER 0721

CONDENSERS

RET-0206(250VA)

RET-0228(150VA)

RET-0203(250VA)

RET-0226(150VA)

CONTROL PANEL

N/A

RET-0237(150VA)

SUFFIX: (-8) 600/3/60

MOTOR

CONTROL VOLTAGE

BY GAS PRESSURE

240V

RET-0225(150VA)

RET-0205(250VA)

RET-0231(250VA)

RER 0720SUFFIX: (-9) 480/3/60

CZR, FZD TZD, PZD

VARIABLE SPEED MOTOR AND CONTROLS

RET-0233(250 VA)

RET-0224(150 VA)

RER 0722

SUFFIX: (-2)

UNIT

RET-0227(150VA)

RET-0202(250VA)

240/1/60

120V

RET-0201(150VA)

RET-0204(250 VA)

SUFIX: (-8) 600/3/60

CONTACTOR

VOLTAGE

6.- Since May 14 2009 supersedes RMT 0180

RGR-0100

5.- Since May 14 2009 supersedes RMT 0140

TRANSFORMER

REP-0118 AND REP-0112

REP-0171 (7)

SINGLE INPUT

N/A

DOUBLE INPUT REP-0118 AND REP-0112 AND REP-0113

CONTROL VOLTAGE 240V

RGR-0142 (5)

SUFFIX: (-9) 480/3/60

REP-0172 (8)

REP-0173 (8)

RET-0239(150VA)

REP-0170 (7)

SUFFIX: (-2) 240/1/60

SUFFIX: (-5) 208/240/3/60 RMT-0013 (1)

(3)

N/A

RGR-0182 (6)

N/A

N/A

RFN-0428

RFN-0428 (3)

10.- Since End of May 2016, supersedes RFN-0108

RGR-0120

RMT-0043 (2) (3)

N/A

CVD, CV8 CVV, CVR CVW, CVX FVD, FVV TVD, TVW

9.- Since Mid-September 2016, supersedes RFN-0107

MOTOR MOUNT

RFN-0040

FAN GUARD RGR-0100

CONDENSER,FLUID COOLER AND GAS COOLER

Page 16: REPLACEMENT PARTS 2020 · 8 NOTE: 1.- All electric defrost units (E) use 4 coil heaters and 2 drain pan heaters. All gas defrost units (G, H) use 2 drain pan heaters. 2.- LSE with

16

CONDENSER,FLUID COOLER AND GAS COOLER

From ToKIT-RFNA RFN old generation RFN new generationKIT-RFNB RMT RFN new generation

Part # Series Part # SeriesRFN-0101 CV,FV,TV (old generation) RFN-0401 CV,FV,TV (new generation)RFN-0102 CV,FV,TV (old generation) RFN-0402 CV,FV,TV (new generation)RFN-0103 CV,FV,TV (old generation) RFN-0403 CV,FV,TV (new generation)RFN-0107 (ECM) CV,FV,TV (old generation) RFN-0407 (ECM) CV,FV,TV, CB, FB, TB (new generation)RFN-0108 (ECM) CV,FV,TV (old generation) RFN-0408 (ECM) CV,FV,TV, CB, FB, TB (new generation)RFN-0111 CB,FB, TB (old generation) RFN-0411 CB,FB, TB (new generation)RFN-0112 CB,FB, TB (old generation) RFN-0412 CB,FB, TB (new generation)RFN-0113 CB,FB, TB (old generation) RFN-0413 CB,FB, TB (new generation)

CL, FL, TL RFN-0401 or RFN-0402 CV,FV,TV (new generation)CL, FL, TL RFN-0411 or RFN-0412 CB,FB, TB (new generation)CL, FL, TL RFN-0403 CV,FV,TV (new generation)CL, FL, TL RFN-0413 CB,FB, TB (new generation)CI, FI, RFN-0401 or RFN-0402 CV,FV,TV (new generation)CI, FI, RFN-0411 or RFN-0412 CB,FB, TB (new generation)CI, FI, RFN-0403 CV,FV,TV (new generation)CI, FI, RFN-0413 CB,FB, TB (new generation)

RMT-0043 (variable speed)* CL, FL, TL, CI, FI RFN-0407(ECM) or RFN-0408 (ECM) CV,FV,TV, CB, FB, TB (new generation)*Can cover more than one voltage

Retro fit kitConvert

From To

KIT-RFNA

KIT-RFNB

RETRO FIT KIT

Retro fit kit

RMT-0090* or RMT-0041*

RMT-0091 or RMT-0042

RMT-0092* or RMT-0051*

RMT-0093 or RMT-0052

Convert

RETRO FIT KIT

Instructions to replace an existing high efficiency motorwith a new generation high efficiency motor

Verify included material:

Image Part # Description

MET‐TR49804 ADAPTATEUR FN080 @ ZN080

RHW‐2054 NUT RETAINER 5/16‐18 TINNERMAN #202‐122

RHW‐3010 5/16‐18 X 1 1/4 FULLTHRD GR2

RHW‐2007 WASHER 5/16 FLAT SAE ZINC

RHW‐2035 LOCK WASHER 5/16 S/S

REM‐2424 LIQUID TIGHT M25x1.5 HEYCO M4344/M4345

REM‐2425 O‐RING 15/16x3/32 W

REM‐2176 LIQUID TIGHT HEYCO M4340

Instructions are valid for the following kit :

KIT-RFNA

Example of components included in a kit (instructions supplied with the kit)

Note : Order should include retro-fit kit plus motor fan assembly

Page 17: REPLACEMENT PARTS 2020 · 8 NOTE: 1.- All electric defrost units (E) use 4 coil heaters and 2 drain pan heaters. All gas defrost units (G, H) use 2 drain pan heaters. 2.- LSE with

17

CONDENSING UNIT

ICH, OCHICZ, OCZ, OVZ, OMZ, ONZ, SCZ, WCZICS, OCS, OVS, OMS, ONS, SCS, WCS

NOTE: 1.- Since february 2004, supersedes RMT 0021.2.- Since february 2004, supersedes REC 0003.3.- Since february 2004, supersede RGR 0140.4.- Since february 2004, supersedes RFN 0040.5.- Since february 2004, supersedes RGR 0100.6.- Since january 2006, supersedes RMT 0016.7.- Since october 2008, supersedes RMT 0041.8.- Since october 2008, supersedes RMT 0042.9.- Units with obsolete motor (RMT 0041 and RMT 0042) use fan blade RFN 005010.- Since May14 2009 supersedes RGR 014011.- Since May14 2009 supersedes RGR 018012.- RFN-0411 supersedes RFN-011113.- RFN-0412 supersedes RFN-0112

RGR-0182 (11)

ZIEHL-ABEGG MOTOR /FAN

SUFFIX-5208-240/3/60

MODELOMZ, OMS

061-220 122-442

RFN-0421 RFN-0411(12)

020-220152-442

REC-0004

REC-0003

FAN MOTOR CAPACITOR

ONZ, ONS 250-500

502-1002

020-220 152-442

RGR-0142 (10)

MOTOR MOUNT

250-400 502-802

ONZ, ONS 250-500

502-1002

RMT-0093

REC-0001 (2)

REC-0003

REC-0001

008-017

SUFFIX-2240/1/60SUFFIX-5

ONZ, ONS 250-500

502-1002

208-240/3/60

RMT-0023

MOTOR

N/A

RMT-0092

250-400 502-1002

FAN GUARD

RMT-0090 (7)

152-802

RFN-0040

ONZ, ONS 250-500

502-1002

SUFFIX-9480/3/60SUFFIX-8600/3/60

SUFFIX-9SUFFIX-9

RMT-0010 (1) (6)

RMT-0015

RGR-0120

480/3/60SUFFIX-8RMT-0033

RGR-0089 (5)

020-220 152-442

RGR-0100

MODEL

240/1/60SUFFIX-5

RFN-0091

SUFFIX-8

MODEL

208-240/3/60

008-017

250-400 502-802

N/A

020-220 152-442

480/3/60

008-017

SUFFIX-8 SUFFIX-9

RET-0207

RMT-0091 (8)

COMPRESSORSINGLE008-220250-400

RMT-0022

SUFFIX-2

RMT-0018

008-017

RFN-0030 (4)

008-017

SHEET METAL BASE (3)

EK007-01 - EK008-01

600/3/60

FAN BLADE

RET-0218

RET-0208RET-0210RET-0219

RET-0211

CONTROL TRANSFORMER

RFN-0422 RFN-0412(13)

RFN-0423 RFN-0413

600/3/60

TWIN

RFN-0090 (9)

020-220152-442

250-400502-802

Page 18: REPLACEMENT PARTS 2020 · 8 NOTE: 1.- All electric defrost units (E) use 4 coil heaters and 2 drain pan heaters. All gas defrost units (G, H) use 2 drain pan heaters. 2.- LSE with

18

CONDENSING UNIT

ICH, OCHICZ, OCZ, OVZ, OMZ, ONZ, SCZ, WCZICS, OCS, OVS, OMS, ONS, SCS, WCS

NOTE: 1.- Since november 2004, RTH-0008 supersedes REP-0050 and since Sept. 2017, RTH-0060 supersedes RTH-0008.2.- Since january 2005, REP-0212 supersedes REP-0232 and since mid-2017, REP-0232 supersedes REP-0212.

REM-2043

REM-2041

REM-2042

DISCONNECT SWITCHCOMPRESSOR CONTACTOR

(COIL 240 VOLTS)RATING (I)0CS(H)(Z)

(W)SCS(Z) (I)OVS(Z)

NON FUSEDFUSED

ALL MODELS

REM-2044REM-2045

REM-2069

REP-0006 RTH-0060 (1) REP-0232 (2) REP-0051

CONTROL PANEL

PRESSURE CONTROLHIGH PRESSURE LOW PRESSURE FAN CYCLING DUAL PRESSURE UNLOADER CONTROL

REP-0004

AIR GAS ELECTRICREM-2031 (2) REM-2031 REM-2031

DEFROST TIMER (240 VOLTS)

REM-2280

REM-2285

160 AREM-2287

60 A80 A90 A

REM-2175

25 A30 A40 A50 A

400 A

RER-0232REM-2280

RER-0236

RER-0233RER-0234RER-0235

200 A

100 A

RER-0237RER-0238

REM-2030

REM-2281

REM-2283

Page 19: REPLACEMENT PARTS 2020 · 8 NOTE: 1.- All electric defrost units (E) use 4 coil heaters and 2 drain pan heaters. All gas defrost units (G, H) use 2 drain pan heaters. 2.- LSE with

19

NOTE: 1.- Since september 2013, supersedes RER-07272.- Since september 2013, supersedes RER-07283.- Supersedes REM-21434.- Supersedes REM-2144

5.- Since january 2005, REP-0212 supersedes REP-0232 and since mid-2017, REP-0232 supersedes REP-0212.

ALL MODELS

RGR-0085

MODELS BETWEEN JUNE 2009 AND OCTOBER 2013

SUFFIX: (-5)

208-240/3/60

RFN-0023

MODELS SINCE JUNE 2009

RFN-0083

FAN BLADE

REC-0022

MOTOR

MODELS BEFOREJUNE 2009

RGR-0130LS005-01

MODELS BEFORE JUNE 2009 MODELS SINCE JUNE 2009

MODEL ALL MODELS

SUFFIX: (-1)RMT-0105

120/1/60

OL120-01 AND OL120-03

PROTECTIVE GRID

ILH, OLH

RMT-0004

RMT 0005

208-240/3/60

240/1/60

SUFFIX: (-5)

SUFFIX: (-1)

RMT 0106

FAN GUARD

ALL MODELS

DEFROST TIMERAIR, GAS AND ELECTRIC

013, 015, 030 ALL MODELS

MODELS SINCE OCTOBER 2013

240/1/60

REP-0232 (5)

120/1/60

SUFFIX: (-2)

ELECTRICAL SUPPLY ALL MODELS

PRESSURE CONTROL

RGR-0050 RGR-0051

OLH 002 TO 015 OLH 018 TO 030

RER-0267 (1) RER-0233 (2)

DISCONNECT SWITCH40A 60A

REM-2289 (3) REM-2290 (4)

COMPRESSOR CONTACTOR

REM-2031120 VOLTS240 VOLTS

120 VOLTS 240 VOLTS

HIGH PRESSURE

REP-0004

LOW PRESSURE

REP-0006

DUAL PRESSURE

MODELS SINCE JUNE 2009MOTOR CAPACITOR

ALL MODELS

REC-0001

REM-2053

002 @ 012, 018 @ 025

RGR-0130

MOTOR MOUNTMODELS BEFORE

JUNE 2009

SUFFIX: (-2)

CONDENSING UNIT

Page 20: REPLACEMENT PARTS 2020 · 8 NOTE: 1.- All electric defrost units (E) use 4 coil heaters and 2 drain pan heaters. All gas defrost units (G, H) use 2 drain pan heaters. 2.- LSE with

20

IEH (Z) (S), OEH (Z) (S)

NOTE: 1.-These motors must be programmed at the factory2.-These motors needs 24V. Power.3.-Since September 2017, supersedes RTH-00084.- Since january 2005, REP-0212 supersedes REP-0232 and since mid-2017, REP-0232 supersedes REP-0212.

N/A N/A480/3/60

1 OR 2 SPEEDS

RMT-0072 (1)

VARIABLE SPEEDS

RMT-0072 (1)

AND RMT-00741 OR 2 SPEEDS

RMT-0073 (1)

VARIABLE SPEEDS

RMT-0073 (1)

AND RMT-0074

1 OR 2 SPEEDS

RMT-0082 (1) (2)

VARIABLE SPEEDS RMT-0082

N/A

SUFFIX: (-8)N/A N/A N/A

600/3/60

SUFFIX: (-2) (-5) 230/1/60

208-230/3/60

1 OR 2 SPEEDS

RMT-0080 (1) (2)

VARIABLE SPEEDS RMT-0080

SUFFIX: (-9)N/A

RGR-0091 RGR-0092

MOTOR MOUNT004 - 010

RGR-0130

ECM MOTORMODEL 004 - 010 013 - 028 030 - 220

N/ASUFFIX: (-1) 120/1/50-60

60 A RER-0236 REM-2281

40 A RER-023450 A RER-0235

RFN-0040RFN-0030RFN-0083

25 A RER-023230 A RER-0233 REM-2280

600/3/60

N/A

N/A

NON FUSED DISCONNECT SWITCH

RMT-0033

SUFFIX: (-9)

480/3/60

SUFFIX: (-8)RMT-0018

CONTROL PANEL

REM-2031

HIGH PRESSURE

RATINGCOMPRESSOR CONTACTOR

(COIL 240 VOLTS)

REP-0004LOW PRESSURE

REP-0006FAN CYCLINGRTH-0060 (3)

DEFROST TIMER

REC-0001N/A

UNLOADER CONTROLDUAL PRESSUREPRESSURE CONTROL

AIR, GAS AND ELECTRIC120 VOLTS REM-2053240 VOLTS

REC-0004REC-0001REC-0022

N/A REC-0003REC-0003

RMT-0010

SUFFIX: (-2)

RMT-0106 RMT-0022240/1/60

SUFFIX: (-5)

208-240/3/60

004 - 010 013 - 028 030 - 220

RMT-0015 RMT-0023

SUFFIX: (-1)

120/1/60RMT-0105 N/A N/A

RGR-0084

FAN GUARD & MOTOR MOUNT030 - 220013 - 028

FAN GUARD004 - 010

FAN BLADE030 - 220013 - 028004 - 010

MOTOR CAPACITOR

030 - 220013 - 028004 - 010

N/AN/AREC-0001

MOTOR

MODEL

100 A REM-2283

80 A RER-023790 A RER-0238

CONTROL TRANSFORMER

SUFFIX: (-8) RET-0208SUFFIX: (-9) RET-0207

REP-0232 (4) REP-0051

CONDENSING UNIT

Page 21: REPLACEMENT PARTS 2020 · 8 NOTE: 1.- All electric defrost units (E) use 4 coil heaters and 2 drain pan heaters. All gas defrost units (G, H) use 2 drain pan heaters. 2.- LSE with

21

GUARDIAN + KE2 DEFROST CONTROLLERS

REFPLUS GUARDIAN (TXV)PART # QTY DESCRIPTION

REM-5391 1 KE2 GUARDIAN CONTROLLER (21231)REM-5388 1 KE2 GUARDIAN DISPLAY C/W 18 IN. CABLE (21791)

REM-5397 1 KE2 TEMP SENSOR KIT (21151)SET OF 3-COLORED SENSORS - 15 FT. (YGB)

REFPLUS GUARDIAN (EEV)PART # QTY DESCRIPTION

REM-5391 1 KE2 GUARDIAN CONTROLLER (21231)REM-5388 1 KE2 GUARDIAN DISPLAY C/W 18 IN. CABLE (21791)REM-5145 2 KE2 TEMPERATURE SENSORS - 10 FT. (20199)

REM-5397 1 KE2 TEMP SENSOR KIT (21151)SET OF 3-COLORED SENSORS - 15 FT. (YGB)

RRV-5621 1 KE2 PRESSURE TRANSDUCERS - 10 FT. (20201)

KE2 TEMPPART # QTY DESCRIPTION

REM-5163 1 KE2 TEMP KIT (20611) TEMPERATURE + DEFROST CONTROLLER FOR AIR DEFROST APPLICATIONS

KIT BEAKDOWN

REM-5421 1 KE2 TEMPERATURE CONTROLLER (20900)REM-5145 1 KE2 TEMPERATURE SENSORS - 10 ft (20199)

KE2 TEMP + VALVE CONTROLPART # QTY DESCRIPTION

REM-5390 1 KE2 TEMP KIT (21301) TEMPERATURE + VALVE CONTROLKIT BEAKDOWN

REM-5423 1 KE2 TEMP + VALVE CONTROL (21393)

REM-5145 2 KE2 TEMPERATURE SENSORS - 10 ft (20199)RRV-5621 1 KE2 PRESSURE TRANSDUCERS - 10 ft (20201)

KE2 LOW TEMPPART # QTY DESCRIPTION

REM-5398 1 KE2 TEMPERATURE CONTROLLER (20968)

REM-5397 1 KE2 TEMPERATURE SENSOR (21151) SET OF 3-COLORED SENSORS - 15 FT. (YGB)

Page 22: REPLACEMENT PARTS 2020 · 8 NOTE: 1.- All electric defrost units (E) use 4 coil heaters and 2 drain pan heaters. All gas defrost units (G, H) use 2 drain pan heaters. 2.- LSE with

22

KE2 EFFICIENCY (TXV)PART # QTY DESCRIPTION

REM-5147 1 KE2 CONTROLLER KIT (20460) W/3 TEMP SENSORSREM-5420 1 KE2 EFFICIENCY CONTROLER (21023)

REM-5397 1 KE2 TEMPERATURE SENSORS (21151) SET OF 3-COLORED SENSORS - 15 FT. (YGB)

REM-5145 1 KE2 TEMPERATURE SENSORS - 10 ft (20199)

KE2 EFFICIENCY (EEV)PART # QTY DESCRIPTION

REM-5147 1 KE2 CONTROLLER KIT (20460) W/3 TEMP SENSORSREM-5420 1 KE2 EFFICIENCY CONTROLER (21023)

REM-5397 1 KE2 TEMPERATURE SENSORS (21151) SET OF 3-COLORED SENSORS - 15 FT. (YGB)

REM-5145 1 KE2 TEMPERATURE SENSORS - 10 ft (20199)RRV-5621 1 KE2 PRESSURE TRANSDUCER (20201)

GUARDIAN + KE2 DEFROST CONTROLLERS

Page 23: REPLACEMENT PARTS 2020 · 8 NOTE: 1.- All electric defrost units (E) use 4 coil heaters and 2 drain pan heaters. All gas defrost units (G, H) use 2 drain pan heaters. 2.- LSE with

23

DESCRIPTION

PART NO. DESCRIPTION

RFN-0101 OBSOLETE REPL. BY RFN-0401

RFN-0102 OBSOLETE REPL. BY RFN-0402

RFN-0103 OBSOLETE REPL. BY RFN-0403

RFN-0107 OBSOLETE REPL. BY RFN-0407

RFN-0108 OBSOLETE REPL. BY RFN-0408

RFN-0111 MOTOR/FAN, 1.00HP, 800 MM, 208/3/60

RFN-0112 MOTOR/FAN, 1.00HP, 800 MM, 460/3/60

RFN-0113 OBSOLETE REPL. BY RFN-0413

RFN-0121 OBSOLETE REPL. BY RFN-0421

RFN-0122 OBSOLETE REPL. BY RFN-0422

RFN-0123 OBSOLETE REPL. BY RFN-0423

RFN-0401 MOTOR/FAN, 1.25HP, 800 MM, 8 POLES, 208/3/60

RFN-0402 MOTOR/FAN, 1.25HP, 800 MM, 8 POLES, 460/3/60

RFN-0403 MOTOR/FAN, 1.25HP, 800 MM, 8 POLES, 575/3/60

RFN-0407 MOTOR/FAN, ECM, 4.6HP, 800 MM, 208/3/60

RFN-0408 MOTOR/FAN, ECM, 3.2HP, 800 MM, 480/3/60

RFN-0411 MOTOR/FAN, 2.6HP, 800 MM, 6 POLES, 208/3/60

RFN-0412 MOTOR/FAN, 2.6HP, 800 MM, 6 POLES, 460/3/60

RFN-0413 MOTOR/FAN, 2.6HP, 800 MM, 6 POLES, 575/3/60

RFN-0421 MOTOR/FAN, 0.9HP, 500 MM, 4 POLES, 208/3/60

RFN-0422 MOTOR/FAN, 0.9HP, 500 MM, 4 POLES, 460/3/60

RFN-0423 MOTOR/FAN, 0.9HP, 500 MM, 4 POLES, 575/3/60RFN-0427 MOTOR/FAN, ECM, 1.2HP, 500 MM, 208/3/60RFN-0428 MOTOR/FAN, ECM, 1.2HP, 500 MM, 460/3/60

MOTORS / FANS

Page 24: REPLACEMENT PARTS 2020 · 8 NOTE: 1.- All electric defrost units (E) use 4 coil heaters and 2 drain pan heaters. All gas defrost units (G, H) use 2 drain pan heaters. 2.- LSE with

24

DESCRIPTION

PART NORMT-0001 1/100 HP, 120/1/60, 3000 RPM, CCW ROT., SK.FRAME, 3/16'' SHAFT

RMT-0002 1/100 HP, 208/240/1/60 (200/220/1/50), 3000 RPM, CCW ROT., SK. FRAME, 3/16'' SHAFT

RMT-0004 (OBSOLETE REPL. BY RMT-0107)

RMT-0005 (OBSOLETE REPL. BY RMT-0108)

RMT-0010 1/4 HP, 208/230/1/60, 1075 RPM, REV. ROT., FRAME 48, 1/2'' SHAFT,TOTALLY ENCLOSED,BALL BRG

RMT-0011 1/20 HP, 120/1/60, 1550 RPM, CCW ROT., 3 1/4'' FRAME, 5/16'' SHAFT

RMT-0012 1/20 HP, 208/240/1/60 (200/220/1/50), 1550 RPM, CCW ROT., 3 1/4'' FRAME, 5/16'' SHAFT

RMT-0013 0.4 HP, 200/230/460/1/60, 1075 RPM, REV.ROT., FRAME 48, 1/2 '' SHAFT

RMT-0014 1/4 HP, 115/1/60, 1075 RPM, 3 SPEEDS, REV. ROT., FRAME 48, 1/2'' SHAFT

RMT-0015 1/4 HP, 460/1/60, 1100 RPM, REV. ROT., FRAME 48, 1/2'' SHAFT

RMT-0016 (OBSOLETE REPL. BY RMT-0010)

RMT-0018 1/4 HP, 575/1/60, 1075 RPM, REV. ROT., FRAME 48, 1/2'' SHAFT

RMT-0019 1/2 HP, 208/230/460/3/60, 560 RPM, REV.ROT., FRAME 56, 5/8 '' SHAFT

RMT-0020 1/2 HP, 575/3/60, 560 RPM, REV.ROT., FRAME 56, 5/8'' SHAFT

RMT-0021 1/4 HP, 208/240/1/60, 825 RPM, REV.ROT., FRAME48, 1/2'' SHAFT

RMT-0022 1/2 HP, 208/240/1/60 (200/220/1/50), 1100 RPM, REV. ROT., FRAME 48, 1/2'' SHAFT

RMT-0023 1/2 HP, 460/1/60, 1100 RPM, REV.ROT., FRAME 48, 1/2'' SHAFT

RMT-0031 1/2 HP, 208/230/460/3/60 (200/220/380/3/50), 1140 RPM, REV.ROT., FRAME 56, 5/8'' SHAFT

RMT-0032 1/2 HP, 575/3/60, 1140 RPM, REV.ROT., FRAME 56, 5/8'' SHAFT

RMT-0033 1/2 HP, 575/1/60, 1100 RPM, REV.ROT., FRAME 48, 1/2'' SHAFT

RMT-0041 (OBSOLETE REPL. BY RMT-0090)

RMT-0042 (OBSOLETE REPL. BY RMT-0091)

RMT-0043 1 HP, 208/230/460/1/60 (200/220/380/1/50), 1075 RPM, REV.ROT., FRAME 56, 5/8'' SHAFT

RMT-0051 (OBSOLETE REPL. BY RMT-0092)

RMT-0052 (OBSOLETE REPL. BY RMT-0093)

RMT-0061 (OBSOLETE)

RMT-0062 (OBSOLETE)

RMT-0070 (OBSOLETE REPL. BY RMT-0072)

RMT-0071 (OBSOLETE REPL. BY RMT-0073)

RMT-0072 1/15 HP, 115/1/60 600-1800 ECM PROG ICE 59

RMT-0073 1/15 HP, 208-230/1/60 600-1800 ECM PROG ICE 59

RMT-0074 CABLE CONVERTISSEUR 0-10VDC ICE59

RMT-0080 1/2 HP ECM 142R, 230/1PH 600/1200RPM

RMT-0082 1/5HP ECM 142R, 240/1/60 200-1200 CW

RMT-0090 1 HP, 208/230/460/3/60 (200/220/380/3/50), 850 RPM, REV.ROT., FRAME 56, 5/8'' SHAFT

RMT-0091 1 HP, 575/3/60, 850 RPM, REV.ROT., FRAME 56, 5/8'' SHAFT

RMT-0092 2 HP, 208/230/460/3/60 (200/220/380/3/50), 1140 RPM, REV.ROT., FRAME 56, 5/8'' SHAFT

RMT-0093 2 HP, 575/3/60, 1140 RPM, REV.ROT., FRAME 56, 5/8'' SHAFT

RMT-0100 (OBSOLETE REPL. BY RMT-0107)

RMT-0101 8 W, 115/1/60, 1550 RPM, CCW ROT, TOT. ENCLOSED SQ SHADED POLE

RMT-0102 (OBSOLETE REPL. BY RMT-0108)

RMT-0103 (1) 8 W, 208/230/1/60, 1550 RPM, CCW ROT, TOT. ENCLOSED SQ SHADED POLE

RMT-0104 EURO BRACKET ADAPTER FOR Q STYLE MOTOR (INCLUDED WITH MOTOR)

RMT-0105 1/12 HP, 115/1/60, 1550 RPM, CWSE ROT, TOT. ENCLOSED, P.S.C. MOTOR

RMT-0106 1/12 HP, 208-230/1/60, 1550 RPM, CWSE ROT, TOT. ENCLOSED, P.S.C. MOTOR

RMT-0107 16W ECM 115/1/60 1400 RPM CCWSE

RMT-0108 18W ECM, 230/1/60 1400 RPM CCWSE

RMT-0109 18W ECM, 115/1/60 300-1400 (0-10V) CCWSE

RMT-0110 18W ECM, 230/1/60 300-1400 (0-10V) CCWSE

MOTORSDESCRIPTION

Page 25: REPLACEMENT PARTS 2020 · 8 NOTE: 1.- All electric defrost units (E) use 4 coil heaters and 2 drain pan heaters. All gas defrost units (G, H) use 2 drain pan heaters. 2.- LSE with

25

DESCRIPTION

PART NO. DESCRIPTIONRFN-0010 6" DIAMETER, 30º PITCH, 4 blades, CW ROTATION, POLYPROPYLENE, HOF "D" 3/16 DIAMETER

RFN-0015 254MM DIAMETER, 28º PITCH, V blades, PLASTIC

RFN-0020 10" DIAMETER, 40º PITCH, 5 blades, CCW ROTATION, POLYPROPYLENE, HOF 5/16" DIAMETER

RFN-0021 10" DIAMETER, 40º PITCH, 5 blades, CW ROTATION, POLYPROPYLENE, HOB 5/16" DIAMETER

RFN-0022 300MM DIAMETER, 22º PITCH, V blades, ALUMINIUM

RFN-0023 300MM DIAMETER, 22º PITCH, A blades, ALUMINIUM

RFN-0026 300MM DIAMETER, 28º PITCH, V blades, ALUMINIUM

RFN-0028 16" DIAMETER, 24º PITCH, 3 blades, CW ROTATION, ALUMINIUM, HOB 1/2" DIAMETER

RFN-0029 16" DIAMETER, 32º PITCH, 3 blades, CW ROTATION, ALUMINIUM, HOB 1/2" DIAMETER

RFN-0030 16" DIAMETER, 40º PITCH, 4 blades, CW ROTATION, ALUMINIUM, HOF 1/2" DIAMETER

RFN-0031 254MM DIAMETER, 22º PITCH, V blades, ALUMINIUM

RFN-0032 OBSOLETE REPL. BY RFN-0015

RFN-0033 200MM DIAMETER, 22º PITCH, V blades, ALUMINIUM

RFN-0034 200MM DIAMETER, 34º PITCH, V blades, PLASTIC

RFN-0036 254MM DIAMETER, 34º PITCH, V blades, ALUMINIUM

RFN-0040 20" DIAMETER, 34º PITCH, 4 blades, CW ROTATION, ALUMINIUM, HOF 1/2" DIAMETER

RFN-0041 20" DIAMETER, 34º PITCH, 4 blades, CW ROTATION, ALUMINIUM, HOF 5/8" DIAMETER

RFN-0050(1) OBSOLETE REPL. BY RFN-0090

RFN-0051(2) OBSOLETE REPL. BY RFN-0091

RFN-0052 30" DIAMETER, 37º PITCH, 5 blades, CW ROTATION, ALUMINIUM, HOF 5/8" DIAMETER

RFN-0053 30" DIAMETER, 22º PITCH, 3 blades, CW ROTATION, ALUMINIUM, HOF 5/8" DIAMETER

RFN-0082 12" DIAMETER, 28º PITCH, 5 blades, CCW ROTATION, ALUMINIUM, HOB 5/16" DIAMETER

RFN-0083 12" DIAMETER, 28º PITCH, 5 blades, CW ROTATION, ALUMINIUM, HOF 5/16" DIAMETER

RFN-0084 254MM DIAMETER, 28º PITCH, A blades, ALUMINIUM

RFN-0090 30" DIAMETER, 30º PITCH, 4 blades, CW ROTATION, ALUMINIUM, HOF 5/8" DIAMETER

RFN-0091 30" DIAMETER, 25º PITCH, 5 blades, CW ROTATION, ALUMINIUM, HOF 5/8" DIAMETER

NOTE: 1 - The replacing fan have to be mount with motor mount RGR-0182 & motor RMT-0090/RMT-0091 2 - The replacing fan have to be mount with motor mount RGR-0182 & motor RMT-0092/RMT-0093

PART NO. DESCRIPTIONRTH-0001 OBSOLETE REPL. BY RTH-0002RTH-0002 THERMOSTAT SPDT, THERMODISC, 14T23, SETTING OPEN 55 ºF RESET 35 ºFRTH-0003 THERMOSTAT SPST, THERMODISC, 14T21, SETTING OPEN 35 ºF RESET 25 ºFRTH-0004 THERMOSTAT SPST, THERMODISC, 14T21, SETTING OPEN 75 ºF RESET 45 ºFRTH-0008 OBSOLETE REPL. BY RTH-0060RTH-0022 ADJUSTABLE THERMOSTAT, RANGE -30 ºF TO 100 ºF, 3 ºF DIFRTH-0023 FOUR STAGE REMOTE BULB THERMOSTAT A36AHA-52C, RANGE 55 oF to 95 OF, 1 1/2 oF DIFRTH-0024 FOUR STAGE REMOTE BULB THERMOSTAT A36AHA-58-C, RANGE 0 oF to 70 oF, 2 1/2 oF DIFRTH-0025 TWO STAGE REMOTE BULB THERMOSTAT A28AA-29C, RANGE -30 oF to 100 oF, 2 oF to 7 oF DIF RTH-0034 TEMPERATURE SENSOR A99BA-200CRTH-0035 TWO STAGE TEMPERATURE CONTROL ETC-212000-000, INPUT 24V, RANGE -30 oF to 220 oF, 1 to 30oF DIF RTH-0037 TWO STAGE TEMPERATURE CONTROL ETC-211000-000, INPUT 120/240V, RANGE -30 oF to 220 oF, 1 to 30oF DIF RTH-0046 CONTROL MODULE C450CBN-3C 1SPDTRTH-0047 CONTROL MODULE C450CCN-3C 2SPDTRTH-0048 EXPANSION MODULE C450SBN-3C 1SPDTRTH-0049 EXPANSION MODULE C450SCN-3C 2SPDTRTH-0060 TEMPERATURE CONTROL RANCO 60-RTH-0202 THERMOSTAT SPDT, THERMODISC, 37T33, SETTING OPEN 55 ºF RESET 35 ºf (Clip on tube 3/8)RTH-0203 THERMOSTAT SPST, THERMODISC, 37T31, SETTING OPEN 35 ºF RESET 25 ºf (Clip on tube 3/8)

PART NO. DESCRIPTIONREM-0003 3 POLESREM-0004 8 POLES

PART NO. DESCRIPTIONREW-0020 DOUBLE & STRAIGHTREW-0030 DOUBLE & PLUGREW-0040 DUMMY

WIRING HARNESS

TERMINAL BOARDS

FAN DELAYS AND DEFROST TERMINATION THERMOSTATS

FAN BLADES

Page 26: REPLACEMENT PARTS 2020 · 8 NOTE: 1.- All electric defrost units (E) use 4 coil heaters and 2 drain pan heaters. All gas defrost units (G, H) use 2 drain pan heaters. 2.- LSE with

26

PART NO. DESCRIPTIONRGR-0040 FAN GUARD FOR 6" FAN, POLYCARBONATERGR-0050 PROTECTIVE GRID 15 x 28RGR-0051 PROTECTIVE GRID 15 x 38RGR-0078 FAN GUARD FOR 10" FAN, POLYCARBONATERGR-0079 FAN GUARD FOR 8" FAN, GREY POLYCARBONATERGR-0080 FAN GUARD FOR 10" FAN, POLYCARBONATERGR-0084 (OBSOLETE) FAN GUARD FOR 12" FAN, BLACK EPOXYRGR-0085 FAN GUARD FOR 12" FAN, GREY PALE POLYCARBONATERGR-0086 FAN GUARD FOR 12" FAN, BLACK EPOXY (FLAT)RGR-0089 FAN GUARD FOR 16" FAN, WELDED WIRE, EPOXY PAINTRGR-0090 FAN GUARD FOR 16" FAN, POLYCARBONATERGR-0091 FAN GUARD + MOTOR MOUNT 16" EPOXY NOIRRGR-0092 FAN GUARD + MOTOR MOUNT 20" EPOXY NOIRRGR-0100 FAN GUARD FOR 20" FAN, WELDED WIRE, EPOXY PAINTRGR-0120 FAN GUARD FOR 30" FAN, WELDED WIRE, EPOXY PAINTRGR-0130 MOTOR MOUNT, FRAME 3 3/8, FOR 12" FAN, WELDED WIRE, EPOXY PAINTRGR-0140 OBSOLETE REPL. BY RGR-0142RGR-0142 MOTOR MOUNT, FRAME 48, FOR 20" FAN, WELDED WIRE, EPOXY PAINT (SOLD IN PAIRS)RGR-0160 OBSOLETE REPL. BY RGR-0162RGR-0162 MOTOR MOUNT, FRAME 56, FOR 20" FAN, WELDED WIRE, EPOXY PAINT (SOLD IN PAIRS)RGR-0180 OBSOLETE REPL. BY RGR-0182RGR-0182 MOTOR MOUNT, FRAME 56, FOR 30" FAN, WELDED WIRE, EPOXY PAINT (SOLD IN PAIRS)

PART NO. DESCRIPTIONREH-0021 * OBSOLETE REPL. BY REH-0041 (REH-0020 FORMED FOR SERIES EDE)REH-0022 * OBSOLETE REPL. BY REH-0051 (REH-0020 FORMED FOR SERIES ESE)REH-0031 * OBSOLETE REPL. BY REH-0051 (REH-0020 FORMED FOR SERIES EDE)REH-0032 * OBSOLETE REPL. BY REH-0061 (REH-0020 FORMED FOR SERIES ESE)REH-0041 ELECTRIC DEFROST HEATER, 480 WATT, 120 VOLT, 10 1/4" LONG "W" SHAPE, 1/4" DIAMETERREH-0042 * OBSOLETE REPLACED BY REH-0041 (REH-0040 FORMED FOR SERIES ESE)REH-0051 ELECTRIC DEFROST HEATER, 640 WATT, 120 VOLT, 14 1/4" LONG "W" SHAPE, 1/4" DIAMETERREH-0061 ELECTRIC DEFROST HEATER, 800 WATT, 120 VOLT, 19 1/4" LONG "W" SHAPE, 1/4" DIAMETERREH-0062 * OBSOLETE REPL. BY REH-0061 (REH-0060 FORMED FOR SERIES ESE)REH-1010 ELECTRIC DEFROST HEATER, 160 WATT, 120 VOLT, 28 1/2" LONG, 1/4" DIAMETERREH-1020 ELECTRIC DEFROST HEATER, 250 WATT, 120 VOLT, 40 1/2" LONG, 1/4" DIAMETERREH-1030 ELECTRIC DEFROST HEATER, 320 WATT, 120 VOLT, 48 1/2" LONG, 1/4" DIAMETERREH-1040 ELECTRIC DEFROST HEATER, 480 WATT, 120 VOLT, 68 1/2" LONG, 1/4" DIAMETERREH-1050 ELECTRIC DEFROST HEATER, 640 WATT, 120 VOLT, 88 1/2" LONG, 1/4" DIAMETERREH-1060 ELECTRIC DEFROST HEATER, 800 WATT, 120 VOLT, 108 1/2" LONG, 1/4" DIAMETERREH-1070 ELECTRIC DEFROST HEATER, 960 WATT, 120 VOLT, 128 1/2" LONG, 1/4" DIAMETERREH-1075 ELECTRIC DEFROST HEATER,1280 WATT, 120 VOLT, 169 1/4" LONG, 1/4" DIAMETERREH-1080 ELECTRIC DEFROST HEATER, 320 WATT, 300 VOLT, 48 1/2" LONG, 3/8" DIAMETERREH-1085 ELECTRIC DEFROST HEATER, 480 WATT, 300 VOLT, 68 1/2" LONG, 3/8" DIAMETERREH-1090 ELECTRIC DEFROST HEATER, 640 WATT, 300 VOLT, 88 1/2" LONG, 3/8" DIAMETERREH-1097 ELECTRIC DEFROST HEATER, 800 WATT, 300 VOLT, 108 1/2" LONG, 3/8" DIAMETERREH-1100 ELECTRIC DEFROST HEATER, 960 WATT, 300 VOLT, 128 1/2" LONG, 3/8" DIAMETERREH-1110 ELECTRIC DEFROST HEATER, 1280 WATT, 300 VOLT, 169 1/4" LONG, 3/8" DIAMETER

* NOTE : Minor modifications are necessary for conversion

FAN GUARDS AND MOTOR MOUNTS

DEFROST HEATERS

DESCRIPTION

Page 27: REPLACEMENT PARTS 2020 · 8 NOTE: 1.- All electric defrost units (E) use 4 coil heaters and 2 drain pan heaters. All gas defrost units (G, H) use 2 drain pan heaters. 2.- LSE with

27

DESCRIPTION

PART NO. DESCRIPTIONREP-0004 HIGH PRESSURE CONTROL ALCO PS3-B6S-405REP-0006 LOW PRESSURE CONTROL, ALCO PS1-X3AREP- 0050 FAN CYCLING PRESSURE CONTROL, JOHNSON P170AA-118CREP-0051 UNLOADER PRESSURE CONTROL, JOHNSON P70CA-1CREP-0061 FAN CYCLING P170AA-400CREP-0112 SENSOR FOR SINGLE INPUT, 100-0016-001 REP-0113 SENSOR FOR DUAL INPUT, 100-0017-001REP- 0118 TEMPERATURE ACTUATED FAN SPEED CONTROL, 816-10DH (HPVD)REP-0170 SPEED CONTROL P266ACA-100CREP-0171 SPEED CONTROL P266BCA-100CREP-0172 ELECTRONIC PRESS TRANS P266SNR-1CREP-0173 ELECTRONIC PRESS TRANS P266SNR-2CREP-0232 DUAL PRESSURE CONTROL, JOHNSON CONTROL, P170SA-1CREP-0212 DUAL PRESSURE CONTROL, ALCO, PS2Y7A

PART NO. DESCRIPTIONRET-0100 50VA, 120V PRIMARY, 24V SECONDARYRET-0201 150VA, 240V PRIMARY, 24V SECONDARYRET-0202 250VA, 600V PRIMARY, 24V SECONDARYRET-0203 250VA, 480V PRIMARY, 120V SECONDARYRET-0204 250VA, 240V PRIMARY, 24V SECONDARYRET-0205 250VA, 600V PRIMARY, 120V SECONDARYRET-0206 250VA, 480V PRIMARY, 24V SECONDARYRET-0207 350VA, 600V PRIMARY, 240V SECONDARYRET-0208 350VA, 480V PRIMARY, 240V SECONDARYRET-0210 500VA, 480V PRIMARY, 240V SECONDARYRET-0211 500VA, 600V PRIMARY, 240V SECONDARYRET-0214 2000VA, 600V PRIMARY, 480V SECONDARY 1PH 50/60 AUTOTRANSFORMERRET-0218 1000VA, 600V PRIMARY, 240V SECONDARYRET-0219 1000VA, 480V PRIMARY, 240V SECONDARYRET-0223 100VA, 240V PRIMARY, 120V SECONDARYRET-0224 150VA, 600V PRIMARY, 120V SECONDARYRET-0225 150VA, 240V PRIMARY, 120V SECONDARYRET-0226 150VA, 480V PRIMARY, 240V SECONDARYRET-0227 150VA, 600V PRIMARY, 240V SECONDARYRET-0228 150VA, 480V PRIMARY, 120V SECONDARYRET-0229 250VA, 600V PRIMARY, 240V SECONDARYRET-0231 250VA, 480V PRIMARY, 240V SECONDARYRET-0233 250VA, 240V PRIMARY, 120V SECONDARYRET-0237 150VA, 600V PRIMARY, 24V SECONDARYRET-0239 150VA, 480V PRIMARY, 24V SECONDARYRET-0280 OBSOLETE REPL. BY RET-0281RET-0281 5000VA,600Y-480Y,60HZ,3PH

PART NO. DESCRIPTIONREM-2031 PARAGON 8145-20 (TIME INITIATED, TEMPERATURE OR PRESSURE TERMINATED)REM-2032 PARAGON 4004-71 (24 HOURS TIME CONTROLS)REM-2053 PARAGON 8145-00

TIMERS

CONDENSER AND CONDENSING UNIT CONTROLS

TRANSFORMERS

Page 28: REPLACEMENT PARTS 2020 · 8 NOTE: 1.- All electric defrost units (E) use 4 coil heaters and 2 drain pan heaters. All gas defrost units (G, H) use 2 drain pan heaters. 2.- LSE with

28

DESCRIPTION

PART NO. DESCRIPTIONRER-0232 CONT 8910DPA23V09 240 VRER-0233 CONT 8910DPA33V09 240 VRER-0234 CONT 8910DPA43V09 240 VRER-0235 CONT 8910DPA53V09 240 VRER-0236 CONT 8910DPA63V09 240 VRER-0237 CONT 8910DPA73V09 240 VRER-0238 CONT 8910DPA93V09 240 VRER-0267 CONT 8910DPA33V02 120 VOLTSRER-0720 CONTACTOR, 14A IND, 3 POLES, 600V CONTACTS, 24V COIL (LOVATO)RER-0721 CONTACTOR, 14A IND, 3 POLES, 600V CONTACTS, 120V COIL (LOVATO)RER-0722 CONTACTOR, 14A IND, 3 POLES, 600V CONTACTS, 230V COIL (LOVATO)RER-0727 CONTACTOR, 30A IND, 3 POLES,600V CONTACTS, 120V COIL (LOVATO)RER-0728 CONTACTOR, 30A IND, 3 POLES,600V CONTACTS, 230V COIL (LOVATO)

PART NO. DESCRIPTIONREM-2030 NON-FUSED DISCONNECT, 400A, 3 POLES, PISTOLREM-2041 FUSED DISCONNECT, 30A, 3 POLES, PISTOLREM-2042 FUSED DISCONNECT, 60A, 3 POLES, PISTOLREM-2043 FUSED DISCONNECT, 100A, 3 POLES, PISTOLREM-2044 FUSED DISCONNECT, 200A, 3 POLES, PISTOLREM-2045 FUSED DISCONNECT, 400A, 3 POLES, PISTOLREM-2069 NON-FUSED DISCONNECT, 200A, 3 POLES, PISTOLREM-2143 DISC OT 32ET3SREM-2144 DISC OT 45ET3SREM-2175 NON-FUSED DISCONNECT, 160A, 3 POLES, PISTOLREM-2280 NON-FUSED DISCONNECT, 30A, 3 POLES, SELECTORREM-2281 NON-FUSED DISCONNECT, 60A, 3 POLES, SELECTORREM-2283 NON-FUSED DISCONNECT, 100A, 3 POLES, SELECTORREM-2285 NON-FUSED DISCONNECT, 60A, 3 POLES, PISTOLREM-2287 NON-FUSED DISCONNECT, 100A, 3 POLES. PISTOLREM-2289 NON-FUSED DISCONNECT, 40A, 3 POLES, SELECTOR (FACE MOUNT)REM-2290 NON-FUSED DISCONNECT, 60A, 3 POLES, SELECTOR (FACE MOUNT)

PART NO. DESCRIPTIONREC-0001 5 MFD @ 370 VAC REC-0003 7,5 MFD @ 370 VAC

REC-0004 10 MFD @ 370 VAC REC-0006 5 MFD @ 440 VACREC-0022 4 MFD @ 370 VAC

PART NO. DESCRIPTIONRHW-1999 M4 K-LOCK NUT, ZP

PART NO. DESCRIPTIONRFT-5135 ADAPTER W-1246, COPPER TO FEMALE NPT, 7/8 x 3/4RFT-8002 STEEL COUPLING 1 1/4 SPTRHW-2010 NEOPRENE WASHER 1/2 x 3/4 x 1/6RHW-2011 NEOPRENE WASHER 15/16 x 1 1/4 x 1/6RHW-4007 BUSHING 3/4, HEX. ALUMINUMRHW-4008 BUSHING 3/8, HEX. ALUMINUMRHW-4009 RETAINING NUT 3/8RHW-4012 BUSHING 1 1/4, ALUMINUMRHW-4013 NEOPRENE WASHER 2 X 1 7/16 X 1/16

CAPACITORS

CONTACTORS

DISCONNECTS

LOCK NUT

DRAIN FITTINGS

Page 29: REPLACEMENT PARTS 2020 · 8 NOTE: 1.- All electric defrost units (E) use 4 coil heaters and 2 drain pan heaters. All gas defrost units (G, H) use 2 drain pan heaters. 2.- LSE with

29

NOTES

Page 30: REPLACEMENT PARTS 2020 · 8 NOTE: 1.- All electric defrost units (E) use 4 coil heaters and 2 drain pan heaters. All gas defrost units (G, H) use 2 drain pan heaters. 2.- LSE with

30

NOTES

Page 31: REPLACEMENT PARTS 2020 · 8 NOTE: 1.- All electric defrost units (E) use 4 coil heaters and 2 drain pan heaters. All gas defrost units (G, H) use 2 drain pan heaters. 2.- LSE with

Redefining Defrost & Temperature Control

Improved Defrost Efficiency: y Off time defrost on schedule or custom de-frost

y Manual defrost y Minimizes frost on evaporator for superior efficiency

y Eliminates ice formation on floors and ceilings for a safer working place

y Eliminates ice formation on products y Post Defrost Indicator reduces service calls, alerts users when controller is coming out of defrost

Guardian+ controls both temperature and defrost, provid-ing you with precision set-point and temperature meas-urement.

It also provides energy savings, 15 to 50% over mechan-ically controlled systems. Ideal for walk-in coolers, closed door display cases, refrigerated warehouses, meat prep rooms, walk-in freezers and blast freezers.

Guardian+ eliminates unnecessary defrosts typically asso-ciated with time-based alternatives thus reducing energy consumption & preserving product integrity.

It also eliminates multiple mechanical controls with pre-cise electronic control.

y Accurate temperature control helps increase product shelf life

y Visual Alarming – High temp/Low temp/Sensor y Compressor protection – Maximum starts per hour y Local / Web-based access to monitor and control sys-tem operations (Smart Access)

y Key pad lockout prevents unauthorized adjustments

First year FREE Smart Access remote monitoring!

Smart Evaporator Control System

Guardian+

Smart Controller

SmartExpansion Valve

EnergySavings!

Page 32: REPLACEMENT PARTS 2020 · 8 NOTE: 1.- All electric defrost units (E) use 4 coil heaters and 2 drain pan heaters. All gas defrost units (G, H) use 2 drain pan heaters. 2.- LSE with

RPL PARTS-En-05/20-R16RefPlus Inc. reserves the right to make any changes in the design or

specifications of any product at any time without notice. © Copyright 2020 by RefPlus Inc.