Manage power consumption, cooling delivery, and temperature set points at a rack level Reduce your cooling and electrical costs by up to 50% Reduce the costs to plan, build, and implement your new facility by up to 80%Grow horizontally—from 1 to 100 units—without disrupting existing operations?Can be installed or Re-Located anywhere with the only requirements being power and network connectivityProvide a complete turnkey solution within weeks vs. years.
Citation preview
ELLIPTICAL MOBILE SOLUTIONS
The Advantages of Micro-Modular Data Centers
What are Micro-Modular Data Centers (MMDCs)
R.A.S.E.R. : 42U
Re-locatable EnclosureC³-S.P.E.A.R.: 24U Mobile, Power Assisted Enclosure
Copyright Elliptical Mobile Solutions 2010, www.ellipticalmobilesolutions.com,
They have all of the characteristics of a Data Center Building. They are designed specifically to support and protect High Density IT equipment.
EMS Produces the only Micro-Modular Data Centers in the World today!
S.P.E.A.R. : 22U Armored, Mobile , Power Assisted Enclosure
R.A.S.E.R. : 42U Re-locatable EnclosureC³-S.P.E.A.R.: 24U Mobile,
Power Assisted Enclosure
3
• Patented, On-board Cooling System - No external cooling source required• Standard 19” Rack Systems - Vendor and Solution Neutral • Mobile/ Re-locatable to easily move from location to location• Patented Shock and Vibration System ensures no damage to equipment occurs during move• Passive and Active On-Board Fire Suppression eliminates fires before damaging equipment• Completely Sealed Systems - equipment inside is protected from the elements•Fully Scalable Systems - useful in a single, remote office to a large data center
CHARACTERISTICS AND BENEFITS
IT Challenges Today
Current Data Center Practices Out Dated Large up front cost before day one of production IT demand moves faster than construction
OPEX 2 out of 3 watts wasted on cooling Maintenance on under utilized infrastructure Cooling Infrastructure driving total electricity usage out of proportion Cost for electricity and services goes up every year
Limited Cooling / Electrical Capacity Inflexible Infrastructure (Once a raised floor always a raised floor) Constant Demand for Expansion Expensive Retrofit for High Density Zone
Industry Direction Change
Modular/Containerized Data Centers • Benefits over Traditional Data Centers Include:
– CAPEX savings of 35-50% – OPEX savings of 20-30%– Time to Deploy from years to 6-8 months
Negatives– Still has large price tag prior to operation
Micro-Modular Data Centers• Benefits over Container Data Centers Include:
– CAPEX Additional savings of 40-50% – OPEX Additional savings of 30-35%– Significant Flexibility– Time to Deploy to 2 months
Copyright Elliptical Mobile Solutions 2010 www.ellipticalmobilesolutions.com
There is a shift occurring in today’s Data Center Design.
Why are companies like IBM, Microsoft, Sun, HP and Google all entering the Modular/Containerized Data Center Market?
• Manage power consumption, cooling delivery, and temperature set points at a rack level
• Reduce your cooling and electrical costs by up to 50%
• Reduce the costs to plan, build, and implement your new facility by up to 80%
• Grow horizontally—from 1 to 100 units—without disrupting existing operations?
• Can be installed or Re-Located anywhere with the only requirements being power and network connectivity
• Provide a complete turnkey solution within weeks vs. years.
What Pre-Engineered Modular Solutions Do For You
What Pre-Engineered Modular Solutions Do For You
Elliptical products only need Power and Connectivity. This allows for endless placement choices.
The Solution is Clear MICRO MODULAR
• Save Money– Eliminate costly infrastructure with a self-contained, high-density, cost-
effective data center.– Reduce the costs to plan, build and implement your data center– Reduce overall operating expenses
• Save Energy– Closed loop cooling dramatically cuts cooling and electrical costs – Significantly reduce data center’s harmful carbon footprint
• Save Time– Micro-Modular Data Centers can be built, fully populated and delivered in
weeks vs. months or years– Have a fully functional data center when, where and for however long you
need it
• Save Space– Reduce your data center footprint by up to 70 percent– EMS products can be located in a warehouse, garage, office or closet
9
THE RASER & C3-SPEAR KEY COMPONENTS
AND
AVAILABLE OPTIONS
9Copyright Elliptical Mobile Solutions 2010 www.ellipticalmobilesolutions.com
R.A.S.E.R. - FEATURES
10
• Micro Modular Design
• 42U NEMA 4 Enclosure
• Vendor Neutral 19” Form Factor
• 42,000 BTU HVAC
• On-Board Closed Loop Cooling
• Hot & Cold Aisle Containment
• Pre-engineered High Density
• Rack Level CyberLock Security
• Mobility
• Easy Serviceability
Copyright Elliptical Mobile Solutions 2010 www.ellipticalmobilesolutions.com
DATA CENTER “IN A BOX”
Equipment
Equipment
Equipment
Equipment
Equipment
RASER – On-Board Closed Loop Cooling
The True Meaning of Built to Last: The A/C “Compressors have a mean time before failure rate of 52.0 years.”
“The A/C blower has a mean time before failure rate of 228.3 years.”
-McLean Cooling Technologies
CLOSED LOOP COOLING REDUCES POWER REQUIRED TO COOL EQUIPMENT BY 50%+
12 KW Air-Cooled
Cold Air
Copyright Elliptical Mobile Solutions 2010 www.ellipticalmobilesolutions.com
*Best Practice for Datacenter Efficiency -LBNL 2008
RASER OVERVIEW
3 “2U” bays for Switches, KVM Infini band extender or communications router.
36U of high density blade ready space
42U Total 100% Self Contained 42,000 Btu A/C, Active Fire Suppression, Security and Protection built in.
Patch Panel
Thermostat
Self-Propelled Push Button
Mobility & Cyber Lock Security
C³-S.P.E.A.R. FEATURES
Dual Power Input & Separate Input for A/C
C3-SPEAR – On-Board Closed Loop Cooling
• Modular Design
•24U NEMA 12 or 4 Enclosure
•Vendor Neutral 19” Form Factor
•8,000-20,000 BTU HVAC
• On-Board Closed Loop Cooling
•Hot & Cold Aisle Containment
•Pre-engineered High Density
•Mobility – Self Propelled Push Button Assist
Push Button Power AssistThe drive system allows one person to move up to 1,500 pounds of electronics and cooling up a 6% grade.*1. Pre-Load the rack in the warehouse.2. Ship to Location for easy set up.3. Park and Lock for instant & Secure IT Closet!
NEMA RATINGS
Type 4 - Enclosures constructed for either Indoor or Outdoor use.
To provide a degree of protection of the equipment insidethe enclosure against ingress of solid foreign objects (falling dirt andwindblown dust); To provide a degree of protection with respect to harmfuleffects on the equipment due to the ingress of (water, rain, sleet, snow,splashing water, and hose directed water); and that will be undamaged bythe external formation of ice on the enclosure.
(RASER, SPEAR AND UPGRADED C3-SPEAR)
Type 12 - Enclosures constructed for Indoor use.
To provide a degree of protection of the equipment inside the enclosure against ingress of solid foreign objects (falling dirt and circulating dust, lint, fibers, and flying); and to provide a degree of protection with respect to harmful effects on the equipment due to the ingress of water
(dripping and light splashing). (Base C3-SPEAR)
Type 12 - Enclosures constructed for Indoor use.
To provide a degree of protection of the equipment inside the enclosure against ingress of solid foreign objects (falling dirt and circulating dust, lint, fibers, and flying); and to provide a degree of protection with respect to harmful effects on the equipment due to the ingress of water
(dripping and light splashing). (Base C3-SPEAR)
AVAILABLE OPTIONS
Equipment
Equipment
Equipment
Equipment
High powered fan will continue to move air
during datacenter power outage
Cool Ambient Air
Hot air from equipment
Copyright Elliptical Mobile Solutions 2009 1
Mission Critical Venting
Close up view
Inside View
• Firetrace Systems provide Cost-Effective, Stand-Alone, Automatic Fire Suppression Systems for Critical Equipment
• Novaec 1230 is a dielectric substance which is harmless to electronic equipment even during operation.
• Novaec 1230 is a totally “clean” (non toxic) agent which eliminates permitting issues and eliminates clean up.
• SMTP remote monitoring available with smart PDU
Active Fire Suppression System
3M™ Novec™ 1230 Fluid 150,000 units installed worldwide
Fire Proofing Insulation
• Aerogel Insulation provides thermal protection from external or internal sources
• Air Tight RASER and C3-SPEAR environments do not support combustion.
• Self contained modules compartmentalize damage to Data Center environment.
Fires in the data center typically initiate through electrical equipment or component failure…”-Lance Harry, business development manager for Fenwal Protection Systems
• Fully Customizable Encrypted Security Access
– Limitation by time or day (9am – 5pm)– Limitation by personnel (Network
Equipment Only or Servers Only)– Monthly Expiration and Renewal
• 4,000 user event auditable trail – Track who opens what and when.
CyberLock Multi-tier Security SystemIntegrated electronic security
Copyright Elliptical Mobile Solutions 2010 www.ellipticalmobilesolutions.com
Field Programmable
Remote Office
( Example Solution)
C3-SPEAR Solution
Laptop
Power
Connectivity
24U ROUTER 24U
23U SWITCH 23U
22U CISCO FIBER CHANNEL 22U
21U CISCO UCS BLADES 21U
20U CISCO UCS BLADES 20U
19U CISCO UCS BLADES 19U
18U CISCO UCS BLADES 18U
17U CISCO UCS BLADES 17U
16U NET APP STORAGE 16U
15U NET APP STORAGE 15U
14U NET APP STORAGE 14U
13U NET APP STORAGE 13U
12U NET APP STORAGE 12U
11U NET APP STORAGE 11U
10U NET APP STORAGE 10U
09U NET APP STORAGE 09U
08U NET APP STORAGE 08U
07U NET APP STORAGE 07U
06U NET APP STORAGE 06U
05U UPS 05U
04U UPS 04U
03U UPS 03U
02U UPS 02U
01U UPS 01U
RASER Solution
Laptop
Power
Connectivity
REMOTE OFFICE DEPLOYMENT
Next Steps:• Do you have a IT Solution in mind?
– How much storage do you need?– What is the rack space requirement in U– What is the heat output of the equipment?
• Do you have a location picked out?– Can you get power and connection and ventilation to this
location?
• What is your time line to complete this project?– When would you like to begin?– When would you like to complete the project?
• Other requirements and consideration
WWW.ELLIPTICALMOBILESOLUTIONS.COM
ELLIPTICAL MOBILE SOLUTIONSThe Leader in Mobile Data Centers