www.escoglobal.com Forced Convection Laboratory Incubators RELIABLE PERFORMANCE FOR UNIVERSAL APPLICATIONS

Reliable PeRfoRmance foR UniveRsal aPPlications ESCO.pdf · - for thermal decoupling Door handle 2. Forced Convection Laboratory Incubators n r - Forced convection design produces

  • Upload
    others

  • View
    3

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Reliable PeRfoRmance foR UniveRsal aPPlications ESCO.pdf · - for thermal decoupling Door handle 2. Forced Convection Laboratory Incubators n r - Forced convection design produces

Forced Convection Laboratory Incubators

www.escoglobal.com

Forced Convection Laboratory Incubators

Reliable PeRfoRmance foR UniveRsal aPPlications

Page 2: Reliable PeRfoRmance foR UniveRsal aPPlications ESCO.pdf · - for thermal decoupling Door handle 2. Forced Convection Laboratory Incubators n r - Forced convection design produces

Forced Convection Laboratory Incubators

Forced Convection Laboratory Incubators

intRodUction

Introducing Esco Isotherm® - world class laboratory incubators from Esco with the technologies and compliance to prove it. Ergonomic, intuitive interfaces, microprocessor PID controls with programming options, 4 zone heated air jacket, precisely tuned and tested ventilation and insulation package, all supported by Esco’s solutions - based sales and service representatives worldwide.

Isotherm® Forced Convection Laboratory Incubators available in 5 sizes,

32L, 54L, 110L, 170L, 240L.

• Innovativedesignguaranteesmaximumthermalperformance.

• Noexposedheatingelementslocatedinsidethechambertoensure maximumusersafety.

• 4zoneheatedairjacketensuresstableheatingandmaximumtemperature uniformity in the chamber.

• Standardtemprangeupto100°Cformaximumapplicationflexibility.

• Secure2pointdoorsealandeccentrichingeensuremaximumgasket compression for stable chamber temperature.

solaRistm PRe-Heat cHambeR tecHnology

Isotherm® Forced convectIon Laboratory

Incubators

Reliable Performance For Universal Applications

Key featURes

ExtremelyUniformThermalDistribution

Pre-heated air enters work

chamber

Pre-heat zone below work chamber

Air supply from outside

Secure2pointdoor seal

Gasket of outer door - for thermal decoupling

Door handle

2

Page 3: Reliable PeRfoRmance foR UniveRsal aPPlications ESCO.pdf · - for thermal decoupling Door handle 2. Forced Convection Laboratory Incubators n r - Forced convection design produces

Forced Convection Laboratory Incubators

Forced Convection

Laboratory Incubator

- Forced convection design produces faster temperature response rates, improveduniformity,andreducedfluctuation.

- German made ebm-papst fan, permanently lubricated, maintenance free for uniform air circulation.

- Low energy consumption for reduced operating costs.

- Fanspeedandairexchangeratesareadjustable.

- Consistent air circulation and heat uniformity.

- Low noise during operation.

- Fresh air entry from the base of the chamber, combined with the rounded cornersofthechamberinterior,andairexhaustattherearofthechamber, createsuniformaircirculationensuringmaximumtemperatureuniformity.

- Chamber fan inlet pulls air away from the user, preventing the user from beingexposedtoblastsofhotairwhenthedoorisopened.

- Electrogalvanized steel with white oven-baked epoxy-polyesterantimicrobialpowder-coated finish.

- ExternalsurfacesarepowdercoatedwithEsco to eliminate 99.9% of surface bacteriawithin24hoursofexposure.

ventiflow™ ventilation system

QUality esco constRUction

- Multilayerchamber,pre-heatchamber,insulationandexternalcarcass.

- Improveschambertemperaturestability,whilereducingexternalsurface temperatures.

- Superiorinsulationperformancereducesheatloadoutputtothelaboratory, reduces operating power consumption, and lowers operating costs.

sUPeRioR insUlation

Isotherm® Forced Convection Laboratory Incubator

3

Page 4: Reliable PeRfoRmance foR UniveRsal aPPlications ESCO.pdf · - for thermal decoupling Door handle 2. Forced Convection Laboratory Incubators n r - Forced convection design produces

Forced Convection Laboratory Incubators

airflow adjusterOpens/ closes rear exhaust vent to adjust airflow for varying applications.

“actual” and “set Point” displaysShow actual temperature and temperature set point at the same time.

led indicatorsIndicate condition of equipment during heating.

main Power switchConveniently accessible.function Keys

For temperature, alarm, program and other settings.

independent adjustable over-temperature thermostatProtects the equipment against overheating.

- Ergonomic door handle, operation is gravity assisted.

- Bright LED displays mounted at top (not base) of the device are easily read from across the laboratory.

- 2 shelves are included for 32L, 54L, 110L, 170L and 240L models.

Access port.

Back View

eRgonomic design imPRoves convenience

access foR temPeRatURe validation and maPPing

• Instrument-gradeprecisionplatinumtemperatureprobe.

• TunedPIDcontrolensuresfastramptime,preventsovershoot,andensures stable temperature once setpoint is achieved.

• Twintemperaturedisplaysforeasymonitoring.

• Built-inmenuisintuitive,easytooperate;leftdisplayshowsparameterbeing set, and right display shows preset value.

• Userprogrammablealarmsetpoints.

• Displayunitsselectablebetween°C/°F.

• UserprogrammablePINtopreventunauthorizeduse.

• Anywherefrom10programswith5segmentsto1programwith50 segments may be configured. Programs may be set up to repeat automatically.

• Audibleconfirmationofallsettings.

• Diagnosticfunctionsprovideaccesstochamberhistoricaltemperaturesand sensor read-outs to simplify service.

• DiagnosticLEDsonelectronicsPCBsimplifyservice.

smaRtsense™ micRoPRocessoR Pid contRol tecHnology

wide Range of PRogRam oPtions

100

80

60

40

20

00 20 40 60 80 100 120 Time (min)

Set Temp = 90 oc

Conventional Control

Fromambient

temp

temp (oc)

temp (oc)

SmartSense PID

sample Program 2Running different processes sequentially based on user’s setting of ‘start temp’, ‘arrival temp’, and running time after arrival. Different programsmaybelinkedtoextendthetotalnumber of sequences, thus creating virtually unlimited programming options.

sample Program 1Repeats of identical processes based on user’s setting of ‘start temp’, ‘arrival temp’, and running time after arrival. All settings can be done in a single program. For example,repeataprocessfrom50°Cto70°Candback.0

20

40

60

80

100

Co

0

20

40

60

80

100

Co

4

Page 5: Reliable PeRfoRmance foR UniveRsal aPPlications ESCO.pdf · - for thermal decoupling Door handle 2. Forced Convection Laboratory Incubators n r - Forced convection design produces

Forced Convection Laboratory Incubators

- Multiple redundant over-temperature protection systems to guarantee maximumsampleanduserprotection.

- Electronic over-temperature protection built into the microprocessor.

- Redundant mechanical over-temperature protection, adjustable from the front, independent from the microprocessor.

- OveralltemperatureprotectionmeetsDIN12880Class3.1.

- RedLEDilluminatesifexternalmechanicaltemperatureprotectionisengaged.

- Controller will control temperature at the over temperature setpoint.

- AllelectricalcomponentsULrecognized.

- ElectricalcircuitprotectioninaccordancewithULrequirements.

access foR temPeRatURe validation and maPPing

safe, sUPeRioR PRotection foR samPle, UseR and tHe enviRonment

oPtional stainless steel exteRioR foRced convection laboRatoRy incUbatoRs aPPlications

secURity featURes to PRotect samPles

Door keylock prevents unauthorized access to sensitive samples.

Door latch and inner door seal toprovideexcellenttemperatureuniformity and accuracy.

Ergonomic door handle, operation is gravity assisted.

5

aPPlication mateRial/ samPle

Bacterial research Bacteria

Microbiology Microorganisms, cells

Coliform determination Bacteria

Histology Tissue

Paraffin embedding Paraffin

Egg incubation Eggs

Heated storage Media, samples

Gene cloning Bacteria, cells

Pharmaceutical stability Various

Food and beverage testing Various

BOD / water pollution Water

Yeast growth Yeast

Hatching of insects, fish Insects

TheRS485providesserialcommunicationportforPC.It can be daisy chained from product to product and connected to PC.

Rs485 commUnication PoRt

- Corrosion resistant surface.

- Robust construction.

- Meets pharmaceutical & clinical laboratory requirements.

Page 6: Reliable PeRfoRmance foR UniveRsal aPPlications ESCO.pdf · - for thermal decoupling Door handle 2. Forced Convection Laboratory Incubators n r - Forced convection design produces

Forced Convection Laboratory Incubators

Wall Mount Bracket

maximized sPace efficiency

SupportStand

• “Cleanroom”designwithminimaljointsandcrevicesiseasytoclean.

• Singlepiecestainlesssteelchamberwithroundedcorners.

• Glassdoorisdismountablewithouttoolsforeasycleaning.

easy-to-clean

- Diagnostic functions in the microprocessor include historical read-out of temperatures.

- Diagnostic menu provides read-out of all sensor inputs and controller settings.

- Servicecanbecarriedoutfromthefront.

- All electronics components are isolated from the work chamber and easily accessible for replacement.

- Low service costs.

easy-to-seRvice

wall mount bracket: Available only for 32L, 54L chambers

support stand: Supportstands,fixedheight, available703mm(27.7”)

oPtions and accessoRiesFORCEDCONvECTIONLABORATORyINCUBATORS

- Wall bracket (only for 32L, 54L chambers) accommodates desired operating heights.

- Supportstands,fixedheight,available703mm(27.7”).

- Reversed door swing. (factory installed)

- Additional shelf.

- Esco Voyager software for the remote monitoring, datalogging, and programming/deviceconfigurationofEscocontrolledenvironmentlaboratory equipment.

- Optional stainless steel cabinet.

6

Page 7: Reliable PeRfoRmance foR UniveRsal aPPlications ESCO.pdf · - for thermal decoupling Door handle 2. Forced Convection Laboratory Incubators n r - Forced convection design produces

Forced Convection Laboratory Incubators

Volume 32 liter (1.13 cu.ft) 54 liter (1.91 cu.ft) 110liter(3.88cu.ft) 170 liter (6.00 cu.ft) 240liter(8.48cu.ft)

Temperature Range Ambient+7.5°Cto100°C

Temperature Variation Per DIN

12880 Spatial Uniformity

at37°C <=+/-0.50C <=+/-0.40C <=+/-0.40C <=+/-0.30C <=+/-0.60C

at50°C <=+/-0.60C <=+/-0.70C <=+/-0.70C <=+/-0.50C <=+/-0.60C

Temperature Fluctuation Per

DIN 12880 Control Fluctuation

at37°C <=+/-0.30C <=+/-0.30C <=+/-0.30C <=+/-0.20C <=+/-0.20C

at50°C <=+/-0.30C <=+/-0.30C <=+/-0.30C <=+/-0.30C <=+/-0.30C

Heating up timeat37°C 29 minutes 34 minutes 40 minutes 44 minutes 50 minutes

at50°C 36 minutes 50 minutes 68minutes 45 minutes 74 minutes

Recovery time after door

opened for 30 sec

at37°C 6 minutes 4 minutes 8minutes 1 minutes 4 minutes

at50°C 8minutes 10 minutes 13 minutes 2 minutes 5 minutes

Electrical data

(220-240V, AC, 50/60Hz,1Ф)

Power consumption at37°C

43 W 49 W 58W 51 W 67 W

Power consumption at50°C

77 W 83W 98W 110 W 115 W

MaximumPowerConsumption**

779W 919W 1097W 1248W 1255W

Noise level 49 dB 48dB 49 dB 51 dB 51 dB

Incubator Construction

Main Body Electrogalvanizedsteelwithwhiteoven-bakedepoxy-polyesterpowder-coatedfinish

Chamber Stainlesssteel,grade304

Number of Shelves

Standard 2 2 2 2 2

Maximum 4 5 6 7 9

Maximum Load Per Shelf 15 kg (33 lbs) 15 kg (33 lbs) 30 kg (66 lbs) 30 kg (66 lbs) 30 kg (66 lbs)

External Dimensions (W x D x H)550x437x615mm 21.7"x17.2"x24.2"

550x527x695mm 21.7”x20.7”x27.4”

710x587x785mm 28”x23.1”x30.9”

740x800x910mm 29.1”x31.5”x35.8”

800x827x1030mm 31.5”x32.6”x40.6”

Internal Dimensions (W x D x H)400x250x320mm 15.7"x9.8"x12.6"

400x340x400mm 15.7"x13.4"x15.7"

560x400x490mm 22”x15.7”x19.3”

580x500x580mm 22.8”x19.7”x22.8”

645x527x700mm 25.4”x20.8”x27.6”

Net Weight 45 kg (99 lbs) 55 kg (121 lbs) 79 kg (174 lbs) 118kg(260lbs) 144kg(318lbs)

Shipping Weight 57 kg (126 lbs) 69 kg (152 lbs) 98kg(216lbs) 140 kg (309 lbs) 166 kg (366 lbs)

Shipping Dimensions, Maximum (W x D x H)

620x530x840mm24.4”x20.9”x33.1”

630x620x920mm24.8”x24.4”x36.2”

780x680x1020mm30.7”x26.8”x40.2”

900x900x1100mm35.4”x35.4”x43.3”

900x900x1200mm35.4”x35.4”x47.2”

Shipping Volume, Maximum 0.37 m3 (13.1 cu.ft) 0.49 m3 (17.3 cu.ft) 0.61 m3 (21.5 cu.ft) 0.89m3 (31.4 cu.ft) 0.97 m3 (34.3 cu.ft)

geneRal sPecifications

NOTE:•Alltechnicalspecificationsarespecifiedforunitswithstandardequipmentatanambienttemperatureof25°Candavoltagefluctuationof±10%.•ThetemperaturedataaredeterminedinaccordancetoDIN2880standardsasperfactorytypetestcondition.•Escoreservestherighttoaltertechnicalspecificationsatalltimes.

*Stainlesssteelexterioroptionisavaiableforallsizes.**Inordertocalculatethecurrentatmaximumpowerconsumption,dividemaximumpowerconsumptionbythevoltage.

ifa-32-8 /ifa-32-8-ss*

ifa-110-8 / ifa-110-8-ss*

ifa-54-8 / ifa-54-8-ss*

ifa-170-8 / ifa-170-8-ss*

ifa-240-8 /ifa-240-8-ss*

FORCEDCONvECTIONLABORATORyINCUBATORS

standards compliance

temperature safety electrical safety

DIN12880Class3.1UL61010-1,USA;CAN/CSA-22.2,No.61010-1;EN61010-1,Europe;IEC61010-1,

Worldwide

7

Page 8: Reliable PeRfoRmance foR UniveRsal aPPlications ESCO.pdf · - for thermal decoupling Door handle 2. Forced Convection Laboratory Incubators n r - Forced convection design produces

Forced Convection Laboratory Incubators

PTEscoBintanIndonesiaCert.No:651333/E

Esco Micro Pte Ltd Cert.No:651076

LIVE SUPPORTescoglobal.com

BiologicalSafetyCabinets

CO2 Incubator

Compounding Pharmacy Equipment

Containment/PharmaProducts

DuctlessFumeHoods

IVF Workstations

Lab Animal Research Products

LaboratoryFumeHoods

Laboratory Incubators

Laboratory Ovens

Laminar Flow Cabinets

MicroplateShaker/Incubator

PCR Cabinets

PCRThermalCyclers

Powder Weighing Balance Enclosures

Ultra-lowTemperatureFreezers

Beijing, China

Guangzhou, China

Shanghai,China

Hanoi,vietnam

Melaka, MalaysiaSingapore

Seoul,Korea

KualaLumpur,Malaysia

Mumbai, India

Delhi, IndiaManama, Bahrain

Salisbury,UK

WORLDCLASS.WORLDWIDE.

9010054_Lab Incubators_IFA_Icebreaker_A4_vC1_03/12 Esco can accept no responsibility for possible errors in catalogues, brochures and other printed materials. Esco reserves the right to alter its products and specifications without notice. All trademarks and logotypes in this material are the property of Esco and the respective companies.

Manila, Philippines

Osaka, JapanPhiladelphia,PA,USA

esco technologies, inc. 2940TurnpikeDrive,Units15-16•Hatboro,PA19040USA

Toll-FreeUSAandCanada877-479-3726

Tel2154419661•Fax2154419660

us.escoglobal.com•[email protected]

esco micro Pte. ltd. 21ChangiSouthStreet1•Singapore486777

Tel+6565420833•Fax+6565426920

[email protected]•www.escoglobal.com

Jakarta, Indonesia

Midrand,SouthAfrica