Upload
others
View
17
Download
0
Embed Size (px)
Citation preview
N-S
B
AS
EL
IN
E
S0
0°0
8'5
2"W
E-W BASELINE
S89°51'08"E
℄ 20' DRIVE
℄ 20' DRIVE
B B
A
A
C
D
D
I I
E E
F F
G G
38
'-6
"
36
'-6
"
13
0'
50'63'
113'
20
'3
8'-6
"5
1'-6
"2
0'
20
'1
5'
20
'
C
CØBØ AØ
AØ
BØ
CØ
AØ
BØ
CØ
AØBØCØ
AØBØCØ
DYNASPHERE
LIGHTNING
PROTECTION
BAY 1
FDR 1
W
W
W
E
E
E
S
S
S
W
W
W
S
S
S
SS
BAY 2
FDR 2
XFMR
BAY 3
FDR 3
BAY 4
FDR 4
(FUTURE)
BØ
BØ
AØ
AØ
CØ
CØ
W
W
W
E
E
E
S
S
S
W
W
W
S
S
S
AØBØCØAØBØCØ
S
C
C
38
6A
385B385B
385B385B
38
6A
38
6A
38
6A
(4)
5
8
"Ø x 2"
TYP
38
6A
38
6A
38
6A
38
6A
H1H2
H3
X0X1X2X3
Z:\4
00
'S
\4
19
\8
21
-C
IT
Y O
F G
LE
NW
OO
D S
PR
IN
GS
-G
LE
ND
WO
OD
S
PR
IN
GS
E
LE
CT
RIC
T C
AR
DN
EL
L S
UB
ST
AT
IO
N\D
RA
WIN
GS
\C
N-E
10
0.D
WG
O
wn
er 4
Ju
ne
2
02
0 1
0:3
4:3
4 A
M
OR
IG
IN
AL
IS
SU
ED
KD
JM
BA
PG
10
/3
1/1
90
1 2 3 4 5 6 7
41
9-8
21
JMB
CIT
Y O
F G
LE
NW
OO
D S
PR
IN
GS
GL
EN
WO
OD
S
PR
IN
GS
, C
OL
OR
AD
O
CA
RD
NE
LL
S
UB
ST
AT
IO
N
GE
NE
RA
L A
RR
AN
GE
ME
NT
CN-E100
No
Dra
wn
Da
te
Re
visio
ns
De
sig
ne
dC
he
cke
d
APPROVED BY:
Pro
j. N
o.
Not For Construction
RELEASE
FOR BID
4-Jun-20
0' 5' 10' 15' 20'
SHEET NOTES:
1. SEE SHEET C001 FOR GRADING AND
FOUNDATION GENERAL NOTES.
2. SURVEY AND TOPOGRAPHY PROVIDED BY:
SGM, INC.
118 W. 6th St.
GLENWOOD SPRINGS, CO
970.945.1004
CLEARANCE CHART:
115kV
PHASE TO PHASE 7'-0"
PHASE TO GROUND 3'-11"
CLEARANCE TO GRADE 12'-0"
METAL TO METAL 4'-5"
SWITCHES VERTICAL BREAK 7'-0"
SWITCHES HORIZONTAL BREAK 9'-0"
15kV
PHASE TO PHASE 2'-0"
PHASE TO GROUND 0'-10"
CLEARANCE TO GRADE 9'-0"
METAL TO METAL 1'-0"
SWITCHES VERTICAL BREAK 2'-0"
SWITCHES HORIZONTAL BREAK 2'-6"
RE
LE
AS
E F
OR
B
ID
JM
BD
KD
AP
G0
6/0
1/2
0
41
9-8
21
6
E210
5
E210
4
E210
3
E210
2
E210
1
E210
15'
XF
MR
AF
DE
28'
22'
15'
LC
TP
T
3'
3'3'
8'
10'
19'
20'
AØBØCØ
D
S
3'
CØ
CØ
SECTION A-A
13'
2'
4'
S
33'-6"
FE
NC
E
10'
12'
OIL CONTAINMENT
AF
DE
COMM / SCADA
CABINET
PULL BOX
AØ BØ CØ
SOURCE
LOAD
8'
1'-6" MIN.
CLEARANCE
3'
CØ
3'-6"
17'
S
1CN202
1CN200
1CN20
3CN1833CN26
3CN25
3CN23
3CN20
3CN22
3CN21
1'-6" 1'-6"
13'
R
S
2'-6"
7'
1'-6"
P
E
N
D
I
N
G
F
I
N
A
L
S
H
O
P
D
W
G
S
P
E
N
D
I
N
G
F
I
N
A
L
S
H
O
P
D
W
G
S
F1 F3
F4F2
C TANK
L
7
E210
C:\U
SE
RS
\O
WN
ER
\D
ES
KT
OP
\E
SC
_P
RO
JE
CT
S\C
AR
DN
EL
L\D
RA
WIN
GS
\C
N-E
20
0X
.D
WG
O
wn
er 2
9 M
ay 2
02
0 1
2:1
0:0
8 P
M
0
1 2 3 4 5 6 7
JMB
CIT
Y O
F G
LE
NW
OO
D S
PR
IN
GS
GL
EN
WO
OD
S
PR
IN
GS
, C
OL
OR
AD
O
CA
RD
NE
LL
S
UB
ST
AT
IO
N
SE
CT
IO
NS
A
-A
CN-E200
No
Dra
wn
Da
te
Re
visio
ns
De
sig
ne
dC
he
cke
d
APPROVED BY:
Pro
j. N
o.
Not For Construction
RELEASE
FOR BID
29-May-20
E24
OR
IG
IN
AL
IS
SU
ED
KD
JM
BA
PG
01
/2
4/2
0
41
9-8
21
BY OTHERS
BY OTHERS
RE
LE
AS
E F
OR
B
ID
JM
BD
KD
AP
G0
6/0
1/2
0
41
9-8
21
1"=10'@11x17
7
E210
6
E210
5
E210
1
E210
30'
SECTION B-B
10'-6"10'-6"
5' 10' 5'10'
HT
R3
SECTION C-C
3'3'
10'
RE
C
27'
1'-6"
AØBØCØ
13'
DS
1'-6"
3'
RECLOSER BYPASS SWITCH BASE SHALL
NOT EXTEND ABOVE TOP TRUSS BEAM TO
MAINTAIN BUS PHASE TO GROUND CLEARANCE.
CONTRACTOR TO
INSTALL GRC CONDUIT
COUPLING WITHIN 6" OF
FINISHED GRADE
9' M
IN
.
PH
AS
E T
O G
RA
DE
SOURCE
LOAD
FE
ED
ER
CO
ND
.
RS
CØ
BØAØ
AØ BØ CØ
AF
DE
AF
DE
2CN200
2CN202
3CN010
3CN13
3CN12
3CN11
TRANSRUPTER
CONTROL
CABINET
9'
HT
R3
TRANSRUPTER
HANDLE
CABINET
8'
1'-6" MIN.
CLEARANCE
3'
CØ
3'-6"
17'
S
1'-6" 1'-6"
2'-6"
7'
1'-6"
40
'
12
'1
2'
10
'
22
'
20
'8
'
6' 9' 9' 6'
P
E
N
D
I
N
G
F
I
N
A
L
S
H
O
P
D
W
G
S
P
E
N
D
I
N
G
F
I
N
A
L
S
H
O
P
D
W
G
S
18
'4
0'
12
'
8
E210
\\E
SC
-D
C2\P
RO
JE
CT
S\400'S
\419\821-C
IT
Y O
F G
LE
NW
OO
D S
PR
IN
GS
-G
LE
ND
WO
OD
S
PR
IN
GS
E
LE
CT
RIC
T C
AR
DN
ELL S
UB
ST
AT
IO
N\D
RA
WIN
GS
\C
N-E
200X
.D
WG
C
ody T
erkhorn 8 June 2020 8:02:36 A
M
CIT
Y O
F G
LE
NW
OO
D S
PR
IN
GS
GLE
NW
OO
D S
PR
IN
GS
, C
OLO
RA
DO
CA
RD
NE
LL S
UB
ST
AT
IO
N
SE
CT
IO
NS
B
-B
, C
-C
, &
D
-D
CN-E201
JMB
765432
1
0
No
Draw
nD
ate
Revisions
Designed
Checked
APPROVED BY:
Proj. N
o.
Not For Construction
RELEASE
FOR BID
29-May-20
NOTES:
RS STRUCTURE SHALL HAVE THE CONDUIT RISER
COME UP ON THE NORTH SIDE
OF THE FOUNDATION.
1.
OR
IG
IN
AL
IS
SU
ED
KD
JM
BA
PG
01
/2
4/2
0
41
9-8
21
BY OTHERS
RE
LE
AS
E F
OR
B
ID
JM
BD
KD
AP
G0
6/0
1/2
0
41
9-8
21
1"=10'@11x17
9
E211
10
E211
11
E211
10
E211
10
E211
10'
MIN
.
INSTALL AC PANEL
IN THIS LOCATION USING
UNI-STRUT ON COLUMN.
7'-6" 7'-6"
3'-6" 4' 4' 3'-6"
SECTION E-E
DS
DS
7'-6" 7'-6"
DS
DS
10'
BA
Y #2
FE
ED
ER
#2
XF
MR
BA
Y #4
FE
ED
ER
#4
(F
UT
UR
E)
16'-3"
℄ S
WIT
CH
19'
8'
BA
Y #3
FE
ED
ER
#3
7'-6" 7'-6"
DS
BA
Y #1
FE
ED
ER
#1
9'
MIN
.
14'-11
1 4
"
17'-11
1 4
"
7'-6" 7'-6"
3'-6"
2'-6"
RECEP.
LIGHT
CONTACTOR
3'-6"
PULL
BOX
FFF
AØBØCØ AØBØCØ AØBØCØ AØBØCØ
DETAIL 1
3'-6"
AC PANEL
WITH INTEGRAL
METER SOCKET
STATION SERVICE
DISCONNECT
DETAIL 1
DETAIL 1
F
3CN277
3CN277
MAIN SIDE
3CN20
3CN23
3CN10
3CN13
3CN30
3CN33
3CN40
3CN43
F F F F
3'-6" 4' 4' 3'-6" 3'-6" 4' 4' 3'-6" 3'-6" 4' 4' 3'-6"
C:\U
SE
RS
\O
WN
ER
\D
ES
KT
OP
\E
SC
_P
RO
JE
CT
S\C
AR
DN
EL
L\D
RA
WIN
GS
\C
N-E
20
0X
.D
WG
O
wn
er 2
9 M
ay 2
02
0 1
2:1
0:4
1 P
M
CIT
Y O
F G
LE
NW
OO
D S
PR
IN
GS
GL
EN
WO
OD
S
PR
IN
GS
, C
OL
OR
AD
O
CA
RD
NE
LL
S
UB
ST
AT
IO
N
SE
CT
IO
N E
-E
CN-E202
JMB
7654321
0
No
Dra
wn
Da
te
Re
visio
ns
De
sig
ne
dC
he
cke
d
APPROVED BY:
Pro
j. N
o.
Not For Construction
RELEASE
FOR BID
29-May-20
OR
IG
IN
AL
IS
SU
ED
KD
JM
BA
PG
01
/2
4/2
0
41
9-8
21
RE
LE
AS
E F
OR
B
ID
JM
BD
KD
AP
G0
6/0
1/2
0
41
9-8
21
1"=10'@11x17
12
E211
12
E211
12
E211
12
E211
7'-6" 7'-6"
SECTION F-F
DS
DS
7'-6" 7'-6"
DS
DS
5'
10'
BA
Y #3
FE
ED
ER
#3
BA
Y #1
FE
ED
ER
#1
16'-0
3 4
"
APPR
OX. ℄
S
WIT
CH
19'
9' M
IN
.
CLE
AR
AN
CE
T
O G
RA
DE
7'-6"
DS
BA
Y #4
FE
ED
ER
#4
(F
UT
UR
E)
7'-6"
BA
Y #2
FE
ED
ER
#2
14'-11
1 4
"
17'-11
1 4
"
3'
RECLOSER BYPASS SWITCH BASE SHALL
NOT EXTEND ABOVE TOP TRUSS BEAM TO
MAINTAIN BUS PHASE TO GROUND CLEARANCE.
7'-6" 7'-6"
SSS
S W S E S
CØBØAØ CØBØAØ CØBØAØ CØBØAØ
CONTRACTOR TO INSTALL UNI-STRUT
IN THIS LOCATION, TO MOUNT S.S. DISCONNECT
SWITCH. SWITCH SHALL BE 200A, 240VAC WITH
LOCKABLE HANDLE IN OPEN POSITION.
SQUARE-D CAT. #H224NRB, NEMA 3R CABINET
TRANSFER SIDE
3CN20 3CN103CN303CN40
3CN42
3CN41
3CN32
3CN31
3CN22
3CN21
3CN12
3CN11
3'-6" 4' 4' 3'-6" 3'-6" 4' 4' 3'-6" 3'-6" 4' 4' 3'-6" 3'-6" 4' 4' 3'-6"
C:\U
SE
RS
\O
WN
ER
\D
ES
KT
OP
\E
SC
_P
RO
JE
CT
S\C
AR
DN
EL
L\D
RA
WIN
GS
\C
N-E
20
0X
.D
WG
O
wn
er 2
9 M
ay 2
02
0 1
2:1
1:0
0 P
M
CIT
Y O
F G
LE
NW
OO
D S
PR
IN
GS
GL
EN
WO
OD
S
PR
IN
GS
, C
OL
OR
AD
O
CA
RD
NE
LL
S
UB
ST
AT
IO
N
SE
CT
IO
N F
-F
CN-E203
JMB
7654321
0
No
Dra
wn
Da
te
Re
visio
ns
De
sig
ne
dC
he
cke
d
APPROVED BY:
Pro
j. N
o.
Not For Construction
RELEASE
FOR BID
29-May-20
1"=10'@11x17
OR
IG
IN
AL
IS
SU
ED
KD
JM
BA
PG
01
/2
4/2
0
41
9-8
21
RE
LE
AS
E F
OR
B
ID
JM
BD
KD
AP
G0
6/0
1/2
0
41
9-8
21
13
E211
13
E211
13
E211
13
E211
14
E211
2'
4'2' 4'
LC
TP
T
LC
TP
T
12'
SECTION I-I
COMM./SCADA
PANEL
CØBØAØ
13'
2'
4'
2' 4' 4' 2'
PULL BOX
SSS
3'-6"
8'
RS
- B
AY
#4
FE
ED
ER
4
(F
UT
UR
E)
SECTION G-G
5'-6"
17'
CONTRACTOR TO
INSTALL CONDUIT
COUPLING WITHIN 6"
OF FINISHED GRADE.
TYPICAL ALL
FEEDER CONDUITS
RS
- B
AY
#3
FE
ED
ER
3
3'-6"
8'
RS
- B
AY
#2
FE
ED
ER
2
4' 4'
5'-6"
17'
CØBØAØ
SSS
RS
- B
AY
#1
FE
ED
ER
1
CAP FEEDER CONDUIT
BY
OTHERS
BY
OTHERS
(FUTURE)
3CN26
3CN25
4' 4'
SSS
4' 4'
SSS
4' 4'
SSS
BY
OTHERS
BY
OTHERS
CØBØAØ CØBØAØ CØBØAØ
C:\U
SE
RS
\O
WN
ER
\D
ES
KT
OP
\E
SC
_P
RO
JE
CT
S\C
AR
DN
EL
L\D
RA
WIN
GS
\C
N-E
20
0X
.D
WG
O
wn
er 2
8 M
ay 2
02
0 4
:4
4:1
6 P
M
CIT
Y O
F G
LE
NW
OO
D S
PR
IN
GS
GL
EN
WO
OD
S
PR
IN
GS
, C
OL
OR
AD
O
CA
RD
NE
LL
S
UB
ST
AT
IO
N
SE
CT
IO
NS
G
-G
, I-I
CN-E204
JMB
7654321
0
No
Dra
wn
Da
te
Re
visio
ns
De
sig
ne
dC
he
cke
d
APPROVED BY:
Pro
j. N
o.
Not For Construction
RELEASE
FOR BID
28-May-20
E24
OR
IG
IN
AL
IS
SU
ED
KD
JM
BA
PG
01
/2
4/2
0
41
9-8
21
RE
LE
AS
E F
OR
B
ID
JM
BD
KD
AP
G0
6/0
1/2
0
41
9-8
21
DETAIL 1
C2
C2
C6
C6A
E10
C24
C2
C6
E7
C6
E21
C2
C6
C18
E11
C3
E12
E23
E19
E14
C14
E13
C21
C9
C15
C16
DETAIL 2 DETAIL 3
DETAIL 5 DETAIL 6 DETAIL 7
SOURCE
LOAD
E20
C2
C21
C15
E13
DETAIL 4
DETAIL 8
C8
NOTE:
CONTRACTOR TO INSTALL
INSULATING WRAP FROM CT AND PT
CONNECTIONS AND THE PT
CONDUCTOR TO THE TAP POINT.
MATERIAL USED, FUSION TAPE BY:
TE CONNECTIVITY
RAYCHEM CABLE PROTECTION,
RED WITH BLUE STRIPE
MANUF. # 608036-1
E13
C22
C1
C41
C22
E13 C1
C14A
C21
E8
C32
C30
E16
C8
C4
C42
E15
C28
C8
C5
E2
C8
C8
C5
C8
E6
C8
C21
C15
C8
C6
C2
E1
C31C30
C2
C9
C6
E7
C6
C14
C1
C40
E5
C2
E5
C1
C1
C14
E4
SOURCE
LOAD
E20
C2
C21
C15
E13
C1
C8
C23
C8
C5
E2
C8
C8
C5
C8
E6
C8
C15
C7
C21
C17
C1
C17
C1
C2
C14
C1
C30
C31
C21
E4
E13
NOTE:
CONNECT TO
H1 SIDE
OF BUSHING
C1 C1
C:\U
SE
RS
\O
WN
ER
\D
ES
KT
OP
\E
SC
_P
RO
JE
CT
S\C
AR
DN
EL
L\D
RA
WIN
GS
\C
N-E
21
0.D
WG
O
wn
er 2
9 M
ay 2
02
0 1
2:1
7:5
5 P
M
0
1 2 3 4 5 6 7
JMB
CIT
Y O
F G
LE
NW
OO
D S
PR
IN
GS
GL
EN
WO
OD
S
PR
IN
GS
, C
OL
OR
AD
O
CA
RD
NE
LL
S
UB
ST
AT
IO
N
BU
S C
ON
NE
CT
IO
N D
ET
AIL
S
CN-E210
No
Dra
wn
Da
te
Re
visio
ns
De
sig
ne
dC
he
cke
d
APPROVED BY:
Pro
j. N
o.
Not For Construction
RELEASE
FOR BID
29-May-20
OR
IG
IN
AL
IS
SU
ED
KD
JM
BA
PG
01
/2
4/2
0
41
9-8
21
1"=10'@11x17
RE
LE
AS
E F
OR
B
ID
JM
BD
KD
AP
G0
6/0
1/2
0
41
9-8
21
DETAIL 9 DETAIL 10 DETAIL 11
DETAIL 12
C3
E9
E18
E9A
C1
E13
C21
C5
C2
C8
E2
C8
C8
C8
C15
E6
E13
C21
C1
C5
C30
C8
E2
C8
C15
C31
C17
E6
E13
C21
C1
BY
OTHERS
CONTRACTOR TO INSTALL CONDUIT
COUPLING WITHIN 6" OF FINISHED GRADE.
TYPICAL ALL FEEDER CONDUITS
DETAIL 13 DETAIL 14
COMM./SCADA
PANEL
E24
C21
E13
C41
C17
E19
E23
E14
E13
C15
C21
C3
E12
C5
C2
C8
E2
C8
C8
C8
C15
C1
E13
C21
E4
E13 C21
C14
C1
C42
C28
C4
AɸBɸCɸ
E16
C3
NOTES:
CONNECT SOURCE TO CT H1 BUSHING.
CONNECT SOURCE PT H1 BUSHING &
GROUND H2 BUSHING.
1.
2.
E15
C8
C3
C31
C17
C5
C7
C14C9
C23X2
\\E
SC
-D
C2\P
RO
JE
CT
S\400'S
\419\821-C
IT
Y O
F G
LE
NW
OO
D S
PR
IN
GS
-G
LE
ND
WO
OD
S
PR
IN
GS
E
LE
CT
RIC
T C
AR
DN
ELL S
UB
ST
AT
IO
N\D
RA
WIN
GS
\C
N-E
210.D
WG
C
ody T
erkhorn 8 June 2020
8:10:20 A
M
CIT
Y O
F G
LE
NW
OO
D S
PR
IN
GS
GLE
NW
OO
D S
PR
IN
GS
, C
OLO
RA
DO
CA
RD
NE
LL S
UB
ST
AT
IO
N
BU
S C
ON
NE
CT
IO
N D
ET
AILS
CN-E211
JMB
7654321
0
No
Draw
nD
ate
Revisions
Designed
Checked
APPROVED BY:
Proj. N
o.
1"=10'@11x17
NOTE:
FEEDER BAY #4 IS FOR FUTURE CIRCUIT. THE
BREAKER AND JUMPERS TO BE INSTALLED AT A
LATER DATE.
1.
Not For Construction
RELEASE
FOR BID
29-May-20
OR
IG
IN
AL
IS
SU
ED
KD
JM
BA
PG
01
/2
4/2
0
41
9-8
21
RE
LE
AS
E F
OR
B
ID
JM
BD
KD
AP
G0
6/0
1/2
0
41
9-8
21
113'
130'
12'
15'
15'
18'
17'
15'
15'
12'
11'
3'
3' 11' 12' 17' 18' 10' 17' 19' 9' 3'
13'
GH3
GH4GH4GH4GH4
GH4
GH4
GH4
GH4
GH4
GH4
GH4
GH4
GH4GH4
GH4
GH4
GH4
GH4
GH4
GH4
GH4
GH4
GH4
GH4
GH4
GH4
GH4
GH3
GH14
GH14GH14
GH3
GH3
GH22
GH3
GH22
GH5 GH6
GH5
GH6
GH5
GH5
GH7
GH6
GH6
GH7
GH7
GH7
GH5
GH3
GH3
GH3
GH3
GH3
GH3
GH3
GH3
GH3
GH3
GH3 GH3 GH3 GH3
GH3
GH3
GH3
GH3
GH3
GH3
GH3
GH3 (TYP)
GH3
GH3
GH3
GH3
GATE STOP
GATE STOP
GATE STOP
GATE STOP
GH9
10'
TYP
GH12
GH4
GH4
3'
GH4
GH4
GH4
GH4
GH14
GH3
GH12
GH5
GH5
GH3
GH9
GH16
GH3
GH3
GH3
GH13
GH4
GH15
GH3
GH15
GH13
GH3
GH3
GH13
GH3
GH13
GH3
GH16
GH3
GH16
GH3
GH16
GH13
GH3
GH8
GH8
GH8
GH3
C:\U
SE
RS
\O
WN
ER
\D
ES
KT
OP
\E
SC
_P
RO
JE
CT
S\C
AR
DN
EL
L\D
RA
WIN
GS
\C
N-E
30
0.D
WG
O
wn
er 2
8 M
ay 2
02
0 4
:4
6:0
5 P
M
0
1 2 3 4 5 6 7
JMB
CIT
Y O
F G
LE
NW
OO
D S
PR
IN
GS
GL
EN
WO
OD
S
PR
IN
GS
, C
OL
OR
AD
O
CA
RD
NE
LL
S
UB
ST
AT
IO
N
GR
OU
ND
IN
G P
LA
N
CN-E300
No
Dra
wn
Da
te
Re
visio
ns
De
sig
ne
dC
he
cke
d
APPROVED BY:
Pro
j. N
o.
Not For Construction
RELEASE
FOR BID
28-May-20
1"= 20' @ 22x34
NOTES:
GRID WILL BE VERIFIED BEFORE SUBSTATION IS PUT INTO SERVICE.
GROUNDING CONDUCTOR IS SHOWN TO EACH STRUCTURE.
IT IS CONTRACTORS RESPONSIBILITY TO ROUTE GROUNDING
CONDUCTOR CORRECTLY TO GROUNDING PAD OR EQUIPMENT.
4/0 CU CABLE REQUIRED FOR ENTIRE GROUND GRID. 4/0 CU TINNED
CABLE IS REQUIRED FOR ALL ABOVE GRADE CONDUCTORS.
4/0 CU GRID CONDUCTOR SHALL BE BURIED 1'-6" BELOW GRADE.
CONTACT ESC ENGINEERING WHEN SITE IS AT GRADE FOR
RESISTIVITY TESTING.
1.
2.
3.
4.
5.
LEGEND
GH4
4/0 BARE COPPER
4/0 TO GROUND ROD
CONNECTION DETAIL SEE DWGS E310, E311, E312
GHxx
OR
IG
IN
AL
IS
SU
ED
KD
JM
BA
PG
10
/3
1/1
9
41
9-8
21
RE
LE
AS
E F
OR
B
ID
JM
BD
KD
AP
G0
6/0
1/2
0
41
9-8
21
DETAIL GH11DETAIL GH10
JUNCTION BOX/CONTROL BOX
310
212
PANEL WALL
265
230
GH11
E310
TO COLUMN GROUND
214
226
TO JUNCTION BOX
GRD BUS
231
JUNCTION BOX
INTERIOR OF
JUNCTION BOX
226
226
302
216
TO GROUND
GRID
212
FOR 2" CONDUIT
OR APPROPRIATE
CLAMP FOR
LARGER CONDUIT
212
TYPE 12 1/2 GA
GALVANIZED BARBED
WIRE
210
211
210
TYPE 12 1/2 GA
GALVANIZED BARBED
WIRE
210
BRACING
ROD
FENCE
FABRIC
TYPE 12 1/2 GA
GALVANIZED BARBED
WIRE
226
300
205
226
301
226
211
211
1-5/8" O.D. TOP RAIL
4/0 COPPER TO 4/0 COPPER 4/0 COPPER TO 3/4" GROUND ROD
1 7/8" GATE FRAME
12"
210
217
216
212
CONTINUOUS LOOP
218
214
10"
2'-4"
LARGE GATE/MAN GATE
CRUSHED ROCK SURFACE
2'-4"
12"
225
301
226
2/0 COPPER TO 4/0 COPPER
2 7/8" O.D.
CORNER POST
1 5/8" O.D. TOP RAIL
225
300
205
211
210
2/0 COPPER TO 3/4" GROUND ROD
1 5/8" O.D. TOP RAIL
1'-0"
12"
AS REQ'D
10"
1'-6"
2'-4"
210
212
214
215
CONTINUOUS LOOP
CRUSHED ROCK SURFACE
FENCE CORNER POST
12"
212
213
214
CRUSHED ROCK SURFACE
2 3/8" O.D. LINE POST
CONTINUOUS LOOP
2'-4"
10"
1'-6"
210
FENCE LINE POST
2'-4"
2'-4"
1'-6"
DETAIL GH1 DETAIL GH2 DETAIL GH3 DETAIL GH4
DETAIL GH7DETAIL GH6DETAIL GH5
X2
N
O
T
U
S
E
D
N
O
T
U
S
E
D
12"
4/0 BARE CU TO FLAT SURFACEOPERATOR PLATFORM (SWITCH)
304
230
SECTION A-A
A
226
GROUND GRID
A
304
15" COPPER BRAID
SUPPLIED BY
SWITCH MANUF.
NOTE:
CONNECTION BETWEEN
SWITCH HANDLE &
OP. PLATFORM MUST BE
VISIBLE
226
301
TO GROUND GRID
235
DETAIL GH8 DETAIL GH9
226
216
216
226
230
IF 4/0 CONDUCTOR CONTINUES
UP THE COLUMN, USE ONE (1) 230
AND ONE (1) 304 CONNECTOR.
CLAMP 2HP FROM COPPER BRAID
BETWEEN 304 AND GROUND TAB.
304
304
x2
x2
x2
x2
226
226
226
GROUND GRID
GROUND GRID
GROUND GRID
OR
235A
302
302
303
OR
230
GATE PANEL
3" O.D. MAN GATE POST
4" O.D. LARGE GATE POST
OR215
C:\U
SE
RS
\O
WN
ER
\D
ES
KT
OP
\E
SC
_P
RO
JE
CT
S\C
AR
DN
EL
L\D
RA
WIN
GS
\C
N-E
31
0.D
WG
O
wn
er 2
8 M
ay 2
02
0 4
:4
6:5
3 P
M
0
1 2 3 4 5 6 7
JMB
CIT
Y O
F G
LE
NW
OO
D S
PR
IN
GS
GL
EN
WO
OD
S
PR
IN
GS
, C
OL
OR
AD
O
CA
RD
NE
LL
S
UB
ST
AT
IO
N
GR
OU
ND
IN
G D
ET
AIL
S
CN-E310
No
Dra
wn
Da
te
Re
visio
ns
De
sig
ne
dC
he
cke
d
APPROVED BY:
Pro
j. N
o.
Not For Construction
RELEASE
FOR BID
28-May-20
NONE
OR
IG
IN
AL
IS
SU
ED
KD
JM
BA
PG
41
9-8
21
OR
IG
IN
AL
IS
SU
ED
KD
JM
BA
PG
01
/2
4/2
0
41
9-8
21
RE
LE
AS
E F
OR
B
ID
JM
BD
KD
AP
G0
6/0
1/2
0
41
9-8
21
DEADEND A-FRAME
TO 4/0
GROUND GRID
SECTION
TO 4/0 GROUND GRID
302
226
230
230
302
226
231
230
226
231
DETAIL GH12
224
214
A
E311
231
226
230
302 302
302
DETAIL GH14
RECLOSER/BREAKER
CONTROL CABINET
GROUND
TO GRD. GRID
FAR SIDE
GH11
E310
DETAIL GH16DETAIL GH15
DISTRIBUTION STRUCTURE - TYPICAL BAY
DETAIL GH13
DETAIL GH18
URD RISER
TO GROUND
GRID
CT/PT STRUCTURE
TO GROUND
GRID
TO GROUND
GRID
5'
TYP
5'
TYP
REGULATOR
TO GROUND GRID
SL L S SL L S SLSL
S.S.
XFMR
STATION SERVICE
GROUNDING
TYP EACH PT
TYP EACH
CT
SLSL
GH11
E310
TO GROUND GRID
TO ADJACENT
REGULATOR
GH20
E312
GH8
E310
214
302
212
226
230
231
226
304
226
230
302
231
226
226226
214
230
302 231
212
226
230
219 219
230
230
302
230
302231
226
226
226
230
302
230
302 231
226
224214
226
304
212
231
230
302
304
226
226
226
226
A
E311
224214
214
226
302
NOTES:
GROUNDING DETAIL IS REPRESENTATIVE OF GROUNDING FOR ALL
RECLOSERS/BREAKERS. SEE EQUIPMENT DRAWINGS FOR EXACT
GROUNDING LOCATIONS.
RUN GROUND CONDUCTOR AND RECLOSER CONTROL CABLE WITHIN
8" OF EACH OTHER.
1.
2.
NOTES:
GROUNDING DETAIL IS REPRESENTATIVE OF GROUNDING FOR ALL
DEADENDS WITH LIGHTNING ARRESTERS.
SEE GH21 FOR DYNASPHERE GROUNDING.
DYNASPHERE GROUND TO BE INDEPENDENT OF SWITCH OPERATOR
GROUNDING.
1.
226
GH21
E312
GH20
E312
302
2.
SEE NOTE 2
GH10
E310
N
O
T
U
S
E
D
x2x2
TWO 4/0 CONDUCTORS
TO 4/0 GROUND GRID
GH10
E310
CT/PT
J-BOX
226
3.
GH9
E310
GH20
E312
304
NOTES:
FEEDING CABLE NEUTRAL SHALL BE GROUNDED
INDEPENDENTLY OF S.A. GROUND.
1.
TO GRD. GRID
5'
TYP
FEEDER CABLE
TERMINATOR
URD
NEUTRAL
226
230
230
302231
226
214
x6
302231
226
226
230
230
214
x3
224 224
224
C:\U
SE
RS
\O
WN
ER
\D
ES
KT
OP
\E
SC
_P
RO
JE
CT
S\C
AR
DN
EL
L\D
RA
WIN
GS
\C
N-E
31
1.D
WG
O
wn
er 2
8 M
ay 2
02
0 4
:4
7:3
4 P
M
0
1 2 3 4 5 6 7
JMB
CIT
Y O
F G
LE
NW
OO
D S
PR
IN
GS
GL
EN
WO
OD
S
PR
IN
GS
, C
OL
OR
AD
O
CA
RD
NE
LL
S
UB
ST
AT
IO
N
GR
OU
ND
IN
G D
ET
AIL
S
CN-E311
No
Dra
wn
Da
te
Re
visio
ns
De
sig
ne
dC
he
cke
d
APPROVED BY:
Pro
j. N
o.
Not For Construction
RELEASE
FOR BID
28-May-20
NONE
OR
IG
IN
AL
IS
SU
ED
KD
JM
BA
PG
01
/2
4/2
0
41
9-8
21
RE
LE
AS
E F
OR
B
ID
JM
BD
KD
AP
G0
6/0
1/2
0
41
9-8
21
DETAIL GH19
TRANSFORMER
NOTES:
TO GRD. GRID
TO GRD. GRID
X3
X2
X1
XO
GRD. PAD AT BASE
FOR Xo BUSHING
GRD.
x3
4/0 CU CONDUCTOR SHALL BE
NEATLY FORMED TO THE TANK
AND FOUNDATION.
SURGE ARRESTER GROUNDS
SHALL BE INDEPENDENT OF THE
Xo BUSHING GRD.
IF GROUND BAR IS NOT PROVIDED,
CONTRACTOR SHALL INSTALL 230
CONNECTORS AS REQ'D TO
CONNECT 4/0 CONDUCTORS
TO SIDE OF XFMR TANK.
TO GRD.
GRID
TO GRD.
GRID
STATIC MAST
OR DEADEND
STATIC WIRE GROUNDING
DETAIL GH20
OHSW
304
304
226
226
304
226
226
304
1.
2.
GRD. PAD AT
BASE FOR
L.A. GRD.
GRD. PAD AT
BASE FOR L.A.
GRD.
219
226
230
302
233
227
3.
IF STATIC ROD IS NOT PROVIDED,
CONTRACTOR SHALL EXTEND 4/0
CONDUCTOR 12" ABOVE TOP PLATE OF
COLUMN
DYNASPHERE
DETAIL GH21
4/0 CU CONDUCTOR DOWN
COLUMN TO CONNECT
TO SUBSTATION GROUND GRID
DYNASPHERE
TRANSRUPTER
DETAIL GH22
230
GH11
E310
214
226
231
226
302
TO GROUND
GRID
212
CONTRACTOR TO EXTEND
4/0 GROUND CONDUCTOR
TO TRANSRUPTER
GROUND LUG
350
352
351
(5) STAINLESS STEEL
PIPE CLAMPS @ 18"
226
6'
354
BY XCEL ENERGY
226
231 302
212
GH11
E310
214
C:\U
SE
RS
\O
WN
ER
\D
ES
KT
OP
\E
SC
_P
RO
JE
CT
S\C
AR
DN
EL
L\D
RA
WIN
GS
\C
N-E
31
2.D
WG
O
wn
er 2
8 M
ay 2
02
0 4
:4
8:0
2 P
M
0
1 2 3 4 5 6 7
JMB
CIT
Y O
F G
LE
NW
OO
D S
PR
IN
GS
GL
EN
WO
OD
S
PR
IN
GS
, C
OL
OR
AD
O
CA
RD
NE
LL
S
UB
ST
AT
IO
N
GR
OU
ND
IN
G D
ET
AIL
S
CN-E312
No
Dra
wn
Da
te
Re
visio
ns
De
sig
ne
dC
he
cke
d
APPROVED BY:
Pro
j. N
o.
Not For Construction
RELEASE
FOR BID
28-May-20
NONE
OR
IG
IN
AL
IS
SU
ED
KD
JM
BA
PG
10
/3
1/1
9
41
9-8
21
RE
LE
AS
E F
OR
B
ID
JM
BD
KD
AP
G0
6/0
1/2
0
41
9-8
21
113'
130'
FDR3
FDR1
F2
F1
F3
L2
D2
D1
C2
C1B2
B1
A2
A1
LIGHT #2
COND.
LIGHTING CONTACTOR (LTS)
LIGHT #3 (L3)
RECEPTACLE #2
PULL BOX FOR
SCADA/COMM
PANEL "G1", "G2"
PULL BOX FOR:
AC PANEL
-SOUTH FACE OF COLUMN
S.S. XFMR DISCONNECT CAB. (SS1)
-NORTH FACE OF COLUMN
L1
LIGHT #1,
RECEP #1
FDR2
GATE STOP
GATE STOP
GATE STOP
GATE STOP
G3
"LTS",
"L3"
STUB OUT LOCATION TO BE DETERMINED
BY CITY OF GLENWOOD SPRINGS.
CONTRACTOR TO ENSURE THAT CONDUITS
DO NOT INTERFERE WITH FENCE POSTS
FDR4
15'
C:\U
SE
RS
\O
WN
ER
\D
ES
KT
OP
\E
SC
_P
RO
JE
CT
S\C
AR
DN
EL
L\D
RA
WIN
GS
\C
N-E
40
0.D
WG
O
wn
er 2
8 M
ay 2
02
0 4
:4
9:0
5 P
M
0
1 2 3 4 5 6 7
JMB
CIT
Y O
F G
LE
NW
OO
D S
PR
IN
GS
GL
EN
WO
OD
S
PR
IN
GS
, C
OL
OR
AD
O
CA
RD
NE
LL
S
UB
ST
AT
IO
N
CO
ND
UIT
P
LA
N
CN-E400
No
Dra
wn
Da
te
Re
visio
ns
De
sig
ne
dC
he
cke
d
APPROVED BY:
Pro
j. N
o.
Not For Construction
RELEASE
FOR BID
28-May-20
1"= 20' @ 22x34
OR
IG
IN
AL
IS
SU
ED
KD
JM
BA
PG
01
/2
4/2
0
41
9-8
21
RE
LE
AS
E F
OR
B
ID
JM
BD
KD
AP
G0
6/0
1/2
0
41
9-8
21
CONDUIT BURIAL DETAIL (TYPICAL)
6"
6" COVER
4"
1'-0" MIN.
CONDUIT MOUNTING & GROUNDING
TO GRD. GRID
SIDE VIEW
DETAIL (TYPICAL)
231
FINAL GRADE
FRONT VIEW
226
6" (MAX.)
FINAL
GRADE
CRUSHED ROCK
SURFACING
UNDISTURBED
SOIL
NON-SELECTED
BACK FILL
PVC CONDUIT
CONTAINING CONTROL OR
POWER CABLES. THE NUMBER OF
CONDUITS WILL VARY.
GRC
FINISHED GRADE
PVC TO GRC ADAPTER
GRC: MALE THREADED FITTING
PVC: FEMALE THREADED FITTING
GRC ELBOW
BOLTED CONDUIT
GROUNDING CLAMP
ANDERSON GC11114C
OR EQUAL
GROUND PAD ON
BASE OF STRUCTURE
PVC
MARKING TAPE
12" BELOW GRADE
YARD LIGHTING
YARD LIGHTING CONTROL
AC PANEL ACP1
NEUTRAL
20 A
15
MAGNETIC CONTACTOR 120V,
3-POLE, 30 AMP,
ELECTRICALLY HELD,
LOCATED NEXT TO AC PANEL
EATON #CN35DN3-A-13
C
PROVIDE HUBBELL LED FLOOD LIGHT. REFER TO
E20 & E21 ON DWG. E600B FOR PART NUMBER.
20 A
17
LGT1 LGT2
LGT3
L1
NOT TO SCALE
L3
L2
YARD LIGHTING DETAILS
GR
C
GRC ELBOW
3'-6"
PROVIDE SIX POINT TERMINAL BLOCK
IN NEMA 3R, 12" x 12" SURFACE MOUNTED
HOUSING.
MOUNT ON STRUCTURE. REFER TO
STRUCTURE SECTION PLANS.
TO YARD LIGHT
GR
C
GRC ELBOW
TRANSITION FROM
PVC TO GRC
℄
FINAL GRADE
TRANSITION FROM
PVC TO GRC
PVC PVC
GR
C
CO
NT
RO
L C
AB
LE
24"
OR
A
M
IN
IM
UM
12" B
EN
EA
TH
O
IL C
ON
TA
IN
ME
NT
LIN
ER
PO
WE
R C
AB
LE
38" M
IN
.
6" F
EE
DE
R C
ON
DU
IT
48"
GRC-GRC COUPLER SHALL BE
INSTALLED WITHIN 6" OF FINISHED
GRADE
226
6" MAX.
GRC-GRC COUPLER SHALL BE
INSTALLED WITHIN 6" OF FINISHED
GRADE
CONDUIT
UNDISTURBED SOIL
6" GRAVEL BASE
BACKFILL
CONDUIT
COVER
GRADE
PULL BOX DETAIL
NO SCALE
13 3/8"
11 1/4"
10 1/4"
SPLICE BOX SHALL BE QUAZITE COMPOSITE BOX WITH OPEN BASE
#PG11188A12 AND QUAZITE COMPOSLITE HEAVY DUTY/TRAFFIC RATED
COVER #PG1118HA00 OR APPROVED EQUAL.
ELECTRICAL
20 1/4"
18 1/8"
12.00"
1 3/4"
FLUSH IN-GRADE PULL BOX DETAIL
NO SCALE
PROVIDE TIE HANDLE ON BREAKERS
WITH COMMON NEUTRAL CONNECTION
LTS1
OUTDOOR LIGHT SWITCH 120V
MOUNTED IN WEATHER PROOF
BOX
STR.
"AFDE"
W. LEG
STR.
"AFDE"
E. LEG
STR.
"DS"
90° ELBOW TYPICAL OF ALL CONDUIT
PHOTO SENSOR
INTERMATIC
K4221C
C:\U
SE
RS
\O
WN
ER
\D
ES
KT
OP
\E
SC
_P
RO
JE
CT
S\C
AR
DN
EL
L\D
RA
WIN
GS
\C
N-E
41
0.D
WG
O
wn
er 2
8 M
ay 2
02
0 4
:4
9:5
0 P
M
0
1 2 3 4 5 6 7
JMB
CIT
Y O
F G
LE
NW
OO
D S
PR
IM
GS
GL
EN
WO
OD
S
PR
IN
GS
CA
RD
NE
LL
S
UB
ST
AT
IO
N
CO
ND
UIT
D
ET
AIL
S
CN-E410
No
Dra
wn
Da
te
Re
visio
ns
De
sig
ne
dC
he
cke
d
APPROVED BY:
Pro
j. N
o.
Not For Construction
RELEASE
FOR BID
28-May-20
NONE
OR
IG
IN
AL
IS
SU
ED
KD
JM
BA
PG
01
/2
4/2
0
41
9-8
21
RE
LE
AS
E F
OR
B
ID
JM
BD
KD
AP
G0
6/0
1/2
0
41
9-8
21
\\E
SC
-D
C2\P
RO
JE
CT
S\400'S
\419\821-C
IT
Y O
F G
LE
NW
OO
D S
PR
IN
GS
-G
LE
ND
WO
OD
S
PR
IN
GS
E
LE
CT
RIC
T C
AR
DN
ELL S
UB
ST
AT
IO
N\D
RA
WIN
GS
\C
N-E
420.D
WG
C
ody T
erkhorn 8 June 2020 9:33:53 A
M
0
1
2 3 4 5 6 7
JMB
CIT
Y O
F G
LE
NW
OO
D S
PR
IM
GS
GLE
NW
OO
D S
PR
IN
GS
, C
OLO
RA
DO
CA
RD
NE
LL S
UB
ST
AT
IO
N
CO
ND
UIT
&
C
AB
LE
S
CH
ED
ULE
CN-E420
No
Draw
nD
ate
Revisions
Designed
Checked
APPROVED BY:
Proj. N
o.
Not For Construction
RELEASE
FOR BID
8-Jun-20
NONE
DUCT BANK
RUN
CONDUIT
RUN
CONDUIT
NO.
QTY. CONDUIT
SIZE
CONDUIT
TYPE
LENGTH
(ft.)
FROM TO CABLE
NO.
QTY SIZE &
# OF CONDUCTORS
TYPE LENGTH FROM FROM DWG TO TO DWG FUNCTION
A1 1 1.5 PVC 25 AC PANEL RECLOSER 1 3CN010-AC 1 3/C #10 XHHW-2 65 AC PANEL REC1 (3CN010) AC POWER FOR RECLOSER 1
A2 1 1.5 PVC 50 SCADA COMM RECLOSER 1 3CN010-S1 1 CAT 5e 90 SCADA/COMM PANEL REC1 (3CN010) COMMUNICATION CABLE FOR RECLOSER 1
B1 1 1.5 PVC 40 AC PANEL RECLOSER 2 3CN020-AC 1 3/C #10 XHHW-2 80 AC PANEL REC2 (3CN020) AC POWER FOR RECLOSER 2
B2 1 1.5 PVC 65 SCADA COMM RECLOSER 2 3CN020-S1 1 CAT 5e 105 SCADA/COMM PANEL REC2 (3CN020) COMMUNICATION CABLE FOR RECLOSER 2
C1 1 1.5 PVC 55 AC PANEL RECLOSER 3 3CN030-AC 1 3/C #10 XHHW-2 95 AC PANEL REC3 (3CN030) AC POWER FOR RECLOSER 3
C2 1 1.5 PVC 80 SCADA COMM RECLOSER 3 3CN030-S1 1 CAT 5e 120 SCADA/COMM PANEL REC3 (3CN030) COMMUNICATION CABLE FOR RECLOSER 3
D1 1 1.5 PVC 70 AC PANEL RECLOSER 4 3CN040-AC 1 3/C #10 XHHW-2 100 AC PANEL REC4 (3CN040) AC POWER FOR RECLOSER 4
D2 1 1.5 PVC 95 SCADA COMM RECLOSER 4 3CN040-S1 1 CAT 5e 135 SCADA/COMM PANEL REC4 (3CN040) COMMUNICATION CABLE FOR RECLOSER 4
F1 1 1.5 PVC 45 AC PANEL TRANSFORMER 2CN20-AC 1 4/C #10 XHHW-2 80 AC PANEL XFMR AC POWER FOR TRANSFORMER
F2 1 3 PVC 25 SCADA COMM PNL TRANSFORMER 2CN20-FO1 1 4 FO Cable 75 SCADA/COMM PANEL XFMR COMMUNICATION CABLE FOR TRANSFORMER
SCADA COMM PNL TRANSFORMER 2CN20-A 1 12/C #12 XHHW-2 75 SCADA/COMM PANEL XFMR ALARM CABLE FOR TRANSFORMER
SCADA COMM PNL TRANSFORMER 2CN20-PT 1 4/C #10 XHHW-2 75 SCADA/COMM PANEL XFMR 12.5kV PT INPUTS FOR LTC
F3 1 3 PVC 50 TRANSRUPTER TRANSFORMER 2CN20-CTN 1 4/C #10 XHHW-2 100 TRANSRUPTER XFMR CT INPUTS FOR RELAYS - NEUTRAL
TRANSRUPTER TRANSFORMER 2CN20-CT1 1 4/C #10 XHHW-2 100 TRANSRUPTER XFMR CT INPUTS FOR RELAYS
TRANSRUPTER TRANSFORMER 2CN20-CT2 1 4/C #10 XHHW-2 100 TRANSRUPTER XFMR CT INPUTS FOR RELAYS (SPARE)
TRANSRUPTER TRANSFORMER 2CN20-B 1 12/C #12 XHHW-2 100 TRANSRUPTER XFMR CONTROL CABLE FOR XFMR TRIP TO TRANSRUPTER
G1 1 2 GRC 20 SCADA COMM PNL 13.2kV METERING PT'S 3CN25-3PT 1 9/C #12 XHHW-2 40 SCADA PANEL 13.2kV METER PT'S 13.2kV PT
G2 1 2 GRC 20 SCADA COMM PNL 13.2kV METERING CT'S 3CN26-3CT 1 9/C #12 XHHW-2 40 SCADA PANEL 13.2kV METER CT'S 13.2kV CT
G3 1 2 PVC 25 AC PNL SCADA PNL COMM-AC 1 4/C #10 XHHW-2 50 AC PANEL COMM PNL AC POWER
LTS 1 1.5 PVC 30 A/C PANEL LIGHTING CONTACTOR LTS1 1 3/C #10 XHHW-2 75 AC PANEL LIGHTING CONTACTOR LIGHTING
L1 1 1.5 PVC 80 LIGHTING CONTACTOR AFDE LIGHTING - EAST LEG LT1 1 3/C #10 XHHW-2 120 LIGHTING CONTACTOR AFDE NORTH LEG LIGHTING
RCPT1 1 3/C #10 XHHW-2 100 AC PANEL DISTRIBUTION STRUCTURE LIGHTING
L2 1 1.5 PVC 50 AFDE LIGHTING - EAST LEG AFDE LIGHTING - WEST LEG LT2 1 3/C #10 XHHW-2 100 AFDE NORTH LEG AFDE SOUTH LEG LIGHTING
L3 1 1.5 GRC 20 LIGHTING CONTACTOR DISTRIBUTION STRUCTURE LT3 1 3/C #10 XHHW-2 40 LIGHTING CONTACTOR LGT 3 LIGHTING
RCPT2 1 3/C #10 XHHW-2 30 AC PANEL DISTRIBUTION STRUCTURE LIGHTING
FDR1 1 6 PVC 110 RISER 1 RE: E400 FDR1 3 BY GSE URD-EPR FEEDER 1 UNDERGROUND FEEDER
FDR2 1 6 PVC 95 RISER 2 RE: E400 FDR2 3 BY GSE URD-EPR FEEDER 2 UNDERGROUND FEEDER
FDR3 1 6 PVC 80 RISER 3 RE: E400 FDR3 3 BY GSE URD-EPR FEEDER 3 UNDERGROUND FEEDER
FDR4 1 6 PVC 65 RISER 4 RE: E400 FDR4 BY GSE (FUTURE) URD-EPR FEEDER 4 UNDERGROUND FEEDER
SS1 1 3 GRC 10 STATION SERVICE TRANSFORMER AC PANEL SS1 3 1/C #3/0 XHHW-2 20 S.S TRANSFORMER AC PANEL STATION SERVICE POWER
NOTES:
1. CAP AND INSTALL PULL WIRE IN ALL FUTURE CONDUIT.
2. FUTURE FEEDER CONDUIT SHALL BE CAPPED AND MARKED ABOVE GROUND WITH A 2"x 6" STOOD VERTICALLY AGAINST CAPPED CONDUIT.
3. FIBER OPTIC CABLE SHALL BE TACTICAL TIGHT-BUFFERRED CABLE, 4 F, 62.5 uM MULTIMODE (OM1), CORNING #004K8U-31130-24 W/ST CONNECTORS
4. CONDUIT RUN WILL INCLUDE GRC ABOVE GRADE RISER, ELBOWS, COULING AND ALL FITTINGS REQUIRED TO COMPLETE CONDUIT INSTALLATION
5. ETHERNET CABLE SHALL BE CAT 5E, SHIELDED -40C TO +75C OPERATING TEMPERATURE RATED, BELDEN #7921A, TERMINATED AT IU PATCH PANEL
ON SCADA/COMM PANEL, WITH SHIELD CONNECTED ONLY AT THE PATCH PANEL.
OR
IG
IN
AL
IS
SU
ED
KD
JM
BA
PG
01
/2
4/2
0
41
9-8
21
RE
LE
AS
E F
OR
B
ID
JA
MC
TW
B5
/2
9/2
02
0
41
9-8
21
ACP1
0 5 6 7
JMB
CIT
Y O
F G
LE
NW
OO
D S
PR
IN
GS
GL
EN
WO
OD
S
PR
IN
GS
, C
OL
OR
AD
O
CA
RD
NE
LL
S
UB
ST
AT
IO
N
AC
P
AN
EL
(A
CP
1)
CN-E540
No
Dra
wn
Da
te
Re
visio
ns
De
sig
ne
dC
he
cke
d
APPROVED BY:
Pro
j. N
o.
C:\E
SC
-W
OR
K\G
LE
NW
OO
D-C
IT
Y O
F\C
AR
DN
EL
L\D
RA
WIN
GS
\C
N-E
54
0.D
WG
W
oo
dy B
oyd 2
8 M
ay 2
02
0 3
:2
5:5
0 P
M
Not For Construction
RELEASE
FOR BID
22-Apr-20
4321
OR
IG
IN
AL
IS
SU
ED
KD
JM
BA
PG
41
9-8
21
OR
IG
IN
AL
IS
SU
ED
KD
JM
BA
PG
01
/2
4/2
0
41
9-8
21
RE
LE
AS
E F
OR
B
ID
JA
MC
TW
B5
/2
9/2
02
0
41
9-8
21
C:\E
SC
-W
OR
K\G
LE
NW
OO
D-C
IT
Y O
F\C
AR
DN
EL
L\D
RA
WIN
GS
\C
N-E
60
0.D
WG
W
oo
dy B
oyd 2
8 M
ay 2
02
0 3
:2
9:0
7 P
M
0
1 2 3 4 5 6 7
JMB
CIT
Y O
F G
LE
NW
OO
D S
PR
IN
GS
GL
EN
WO
OD
S
PR
IN
GS
, C
OL
OR
AD
O
CA
RD
NE
LL
S
UB
ST
AT
IO
N
GR
OU
ND
IN
G M
AT
ER
IA
L L
IS
T
CN-E600A
No
Dra
wn
Da
te
Re
visio
ns
De
sig
ne
dC
he
cke
d
APPROVED BY:
Pro
j. N
o.
Not For Construction
RELEASE
FOR BID
22-Apr-20
NONE
ITEM
NO.
QTY GROUNDING MATERIAL DESCRIPTION MAN. CAT.
N0.
205 - GROUND ROD, 3/4" x 10'-0" BLACKBURN 7510
206 - GROUND ROD, 3/4" x 10'-0", SECTIONAL BLACKBURN 7510S
207 - COUPLING, 3/4" BLACKBURN 70C
208 - DRIVING STUD, 3/4" (REUSEABLE) BLACKBURN 70DS
210 - CONNECTOR, BOLTED, #2 TO #8 STRANDED Cu TO FENCE FABRIC, TIN PLATED BLACKBURN 1HPS
211 - CONNECTOR, BOLTED, #2 SOLID Cu TO 1 5/8" OR 1 7/8" O.D. PIPE ANDERSON GC-111-5B
212 - CONDUCTOR #2 SOLID Cu, SOFT DRAWN, TINNED WEST -
213 - CONNECTOR, BOLTED, 2/0-250MCM Cu TO 2 1/2" O.D. PIPE ANDERSON GC-110-82C
214 - CONNECTOR, COMPRESSION, 3/0 Cu- 250MCM TO #6 SOL Cu-2/0 STRANDED Cu, TIN PLATED BURNDY YGHC29C26-TN
215 - CONNECTOR, BOLTED, #2/0 - 250MCM Cu TO 3" O.D. PIPE ANDERSON GC-110-102C
216 - CONNECTOR, BOLTED, Cu BRAID TO 2" O.D. PIPE ANDERSON GC-109-06
217 - CONDUCTOR Cu BRAID, FLEXIBLE, 24" LONG ANDERSON GB2005B
218 - CONNECTOR, BOLTED, 2/0-250MCM TO 4 1/2" O.D. PIPE ANDERSON GC-111-11C
219 - CONNECTOR, BOLTED, 2/0-250MCM Cu TO 2" O.D. PIPE ANDERSON GC-110-62C
224 - CONDUCTOR #4 STRANDED Cu, TINNED WEST -
225 - CONDUCTOR #2/0 STRANDED Cu, TINNED, .414" DIA WEST -
226 - CONDUCTOR #4/0 STRANDED Cu. (TINNED ABOVE GRADE ONLY) WEST -
227 - SHIELD WIRE, 3/8" HSS - -
228 - NOT USED - -
229 - NOT USED - -
230 - CONNECTOR, BOLTED, (1) #4-300MCM CU TO FLAT SURFACE, 1/2"-13 BOLT, FOR 3/8" PLATE ANDERSON GC-141-A0238
231 - CONNECTOR, BOLTED, (2) #4-300MCM CU TO FLAT SURFACE, 1/2"-13 BOLT, FOR 3/8" PLATE ANDERSON GC-143-A0238
232 - CONNECTOR, BOLTED, #8 SOLID CU-250MCM BURNDY KS29
233 - SPLICE, COMPRESSION, 4/0 Cu TO 3/8" EHS STEEL BLACKBURN WR-399
234 - NOT USED - -
235 - SWITCH OPERATORS GROUNDING PLATFORM, 3'x 6' STEEL SUPPLIER
235A - SWITCH OPERATORS GROUNDING PLATFORM, U-SHAPED STEEL SUPPLIER
236 - CABLE SUPPORT, FOR RIGID CONDUIT w/WEDGING PLUG 3-750 MCM CABLES, 1.96" O.D. O-Z/GEDNEY DR-6002-1
237 - CONDUIT CLAMP, RIGHT ANGLE OR PARALLEL CONNECTED, 6" CONDUIT TO #2/0-250MCM Cu ANDERSON GC11114C
238 - CONNECTOR, COMPRESSION, #1-2/0 STRANDED CU TO #1-2/0 STRANDED CU BURNDY YGHC26C26
241 - CONNECTOR, SPLIT BOLT TYPE, #14 SOLID CU TO 2/0 Cu BURNDY KS26
242 - NOT USED - -
243 - CONNECTOR, BOLTED, #2/0-250MCM CU TO 4" O.D. PIPE ANDERSON GC-111-10C
265 - TERMINAL Cu, COMPRESSION, #4-2/0 SOLID TO 3/8" HOLE ANDERSON VHCS2038
300 - CONNECTOR HYGRID CROSS, #2 STR - 250MCM TO 3/4" GROUND ROD OR #2 STRANDED-250MCM TO 250MCM-500MCM BURNDY YGL34C29
300A - NOT USED - -
301 - CONNECTOR HYGRID CROSS, #2 STR - 250MCM TO #2 STR - 250MCM BURNDY YGL29C29
302 - CONNECTOR HYTAP 3/0 STR- 250KCM TO 3/0 STR-250KCM BURNDY YGHC29C29
303 - NUT, 5/8" - -
304 - TERMINAL HYLUG HEAVY DUTY 4/0 TO 2 HP. TIN PLATED BURNDY YGHA28-2N-TN
305 - TERMINAL HYLUG HEAVY DUTY 2/0 TO 2 HP BURNDY YGHA26-2N-TN
310 - GROUNDING CONNECTOR, CABLE TO FLAT, 1-4/0 AWG, 5/8" STUD BURNDY KC28
LIGHTNING PROTECTION MATERIAL - DYNASPHERE
ITEM
NO.
QTY MATERIAL DESCRIPTION MAN. CAT. N0.
350 1 ERICO DYNASPHERE, MKIV, SS ERICO D/SMKIVSS
351 1 MAST, AL 6M ERICO ALUM6M
352 1 ADAPTER, TERMINAL TO LUG OR TAPE ERICO TERMLUGCOUP
353 1 MOLD, CABLE TO BUS/LUG, HORIZONTAL SPLICE LUG FLAT ERICO LAC8D002
354 5 MAST BRACKET, U-BOLT ERICO UBOLT
355 35 COPPER, 5/8" CABLE STRAP, ONE HOLE ERICO LPC805
356 35 SCREW, SHEET METAL,#10x5/8 ERICO A927P023
OR
IG
IN
AL
IS
SU
ED
KD
JM
BA
PG
41
9-8
21
OR
IG
IN
AL
IS
SU
ED
KD
JM
BA
PG
01
/2
4/2
0
41
9-8
21
RE
LE
AS
E F
OR
B
ID
JA
MC
TW
B5
/2
9/2
02
0
41
9-8
21
C:\E
SC
-W
OR
K\G
LE
NW
OO
D-C
IT
Y O
F\C
AR
DN
EL
L\D
RA
WIN
GS
\C
N-E
60
0.D
WG
W
oo
dy B
oyd 2
8 M
ay 2
02
0 3
:3
2:0
5 P
M
CIT
Y O
F G
LE
NW
OO
D S
PR
IN
GS
GL
EN
WO
OD
S
PR
IN
GS
, C
OL
OR
AD
O
CA
RD
NE
LL
S
UB
ST
AT
IO
N
EQ
UIP
ME
NT
M
AT
ER
IA
L L
IS
T
CN-E600B
JMB
7654321
0
No
Dra
wn
Da
te
Re
visio
ns
De
sig
ne
dC
he
cke
d
APPROVED BY:
Pro
j. N
o.
Not For Construction
RELEASE
FOR BID
28-May-20
NONE
OWNER
FURNISHED
ITEM
NO.
QTY EQUIPMENT MATERIAL DESCRIPTION MAN. CAT. NO.
X E1 1 TRANSFORMER, POWER 115kV X 69kV-13.2/7.62kV, 10/12.5/14 MVA VIRGINIA TRANS.
X E2 3 RECLOSER, TYPE NOVA THREE PHASE SINGLE TANK, 15.5kV, 110kV BIL, 630A CONT., 12.5kA INTERRUPTION, 120VAC HEATERW/KA44RE1 PLUG-IN, 2 HOLE PAD, INTERNAL VOLTAGE SENSING, STANDARD ALUMINUM HOUSING, SUBSTATION FRAME,BIRDGUARDS; FORM 4D02 6 CONTROL, 13AH BATTERY, 1A CT, MILD-STEEL CABINET, 2 SETS UNIVERSAL CONTACTS, DNPCOMMUNICATION, ETHERNET 10/100 BASE T/TX RTAC CABLE & CONVENIENCE OUTLET
EATON/COOPER KNOVA15A31KNOVA-848KA97ME-10KNOVA59-1KNOVA56-6KSTS201-2
KME4DPA1000020800EKA1ME-10
KME4D-1775CKA13 MEI-10
KME4D-3799AKME4D-1776
E3
X E4 12 SWITCH, RECLOSER BYPASS, 15kV, 110kV BIL, 600A, PORCELAIN INSULATORS, TYPE BT ROYAL 13212
X E5 3 INSULATOR, 115kV,550kV BIL, TR286, 5" B.C. NEWELL 47801
X E6 12 SWITCH, HOOKSTICK DISCONNECT, 15kV, 110kV, 600A, TYPE BT ROYAL 13004
X E7 1 SWITCH, GROUP OPERATED, "V" TYPE, 115kV, 350kV BIL, 1200A, VERTICAL MOUNT, SWING HANDLE ROYAL AV11512
X E8 1 SWITCH, GROUP OPERATED, "V" TYPE, 15kV, 110kV BIL, 1200A, HORIZONTAL MOUNT, SWING HANDLE ROYAL AV1512
X E9 1 SWITCH FUSED DISCONNECT 15kV, 110kV BIL, SMD-20 (STATION SERVICE) BRONZE/TIN PLATED CONNECTOR FOR #2SOLID-397.5kCMIL ACSR
S&C 192232R3-K
X E9A 2 FUSE UNIT SMU-20 5E STANDARD SPEED (STATION SERVICE) S&C 612005
X E10 1 TRANSRUPTER II, MODEL SE, 115kV, (ENERGIZED AT 69kV) 420A, 4,200A INTERRUPTION, W/BYPASS SWITCH, FOUR (4) SELFPOWERED PROTECTIVE RELAYS (5A SECONDARY), TEST SWITCH, REMOTE GAS DENSITY ALARM, 84" PHASE SPACING, 8'PEDESTAL, ANCHOR BOLTS INCLUDED (S-81365-1)
S&C 319018R1-J5-F-H-R-U5-E84-S 81365-1
X E11 3 SURGE ARRESTER, 115kV, 70/42kV MCOV, DUAL RATED TYPE EVP W/SHORTING BAR. HUBBELL EVP907102-3001
X E12 12 SURGE ARRESTER, 15kV, 110kV BIL, 8.4kV MCOV 10kV DUTY CYCLE, NUT AND WIRE CLAMP; INSULATED BASE W/ISOLATOR, TYPEOPTIMA PDV-100, W/PROTECTIVE CAP
OHIO BRASS 213709-7314
X E13 51 INSULATOR, 15kV,110kV BIL, TR205, 3" B.C. NEWELL 231002
E14 9 TERMINATOR, COLD SHRINK, 750MCM URD (E23), 1.53-2.32 O.D., INSTALLER MUST SUPPLY 2 HOLE PAD FOR COMPLETETERMINATION
3M 7666-S-8
X E15 3 TRANSFORMER CURRENT 13.2kV 110kV BIL 600:5A 0.15B-1.8 TYPE CRE-17, COLOR ANSI GREY ARTECHE 756206120
X E16 3 TRANSFORMER POTENTIAL 13.2kV 110kV BIL 63.5:1 0.3W,X,M,Y, TYPE VRN-17, COLOR ANSI GREY ARTECHE 757101063
X E18 1 TRANSFORMER, STATION SERVICE, 7.62kV-120/240V AC, 10kVA
E19 9 CABLE POSITIONER 3/4" - 3" CABLE, MODEL CS-820 ALUMA-FORM 51919
E20 2 LIGHT 120V LED FLOOD STEEL STRUCTURE MOUNTED, LARAMIE/LFS SERIES - MEDIUM DISTRIBUTION, 475 LUMENS2" PIPE (2 3/8" O.D.) SLIP FITTER W/ 1/2" TOP HUB, BRONZE, MOUNT 45 DEG. FROM VERTICAL
SPAULDINGLIGHTING
LFS-LED2-1-BZ-LP-S-302-M51
E21 2 LIGHT 120V LED LARGE AREA FLOOD, STRUCTURE MOUNTED, MAGNULITER, MEDIUM DISTRIBUTION, 5879 LUMENSMOUNT 30 DEG. FROM VERTICAL
HUBBEL MLED-80LU-5K-M
E23 TBDBY
CLIENT
CONDUCTOR, UNDER GROUND JACKETED CONCENTRIC NEUTRAL, 15kV, 750MCM, 133% INSULATION, OKONITE 160-23-3096
E24 1 COMMUNICATION CABINET SPECIALTYELECTRIC
OR
IG
IN
AL
IS
SU
ED
KD
JM
BA
PG
01
/2
4/2
0
41
9-8
21
RE
LE
AS
E F
OR
B
ID
JA
MC
TW
B5
/2
9/2
02
0
41
9-8
21
C:\E
SC
-W
OR
K\G
LE
NW
OO
D-C
IT
Y O
F\C
AR
DN
EL
L\D
RA
WIN
GS
\C
N-E
60
0.D
WG
W
oo
dy B
oyd 2
9 M
ay 2
02
0 9
:0
2:2
0 A
M
CIT
Y O
F G
LE
NW
OO
D S
PR
IN
GS
GL
EN
WO
OD
S
PR
IN
GS
, C
OL
OR
AD
O
CA
RD
NE
LL
S
UB
ST
AT
IO
N
CO
ND
UC
TO
R, C
ON
NE
CT
IO
N, E
TC
. M
AT
ER
IA
L L
IS
T
CN-E600C
JMB
7654321
0
No
Dra
wn
Da
te
Re
visio
ns
De
sig
ne
dC
he
cke
d
APPROVED BY:
Pro
j. N
o.
Not For Construction
RELEASE
FOR BID
28-May-20
NONE
OWNER
FURNISHED
ITEM
NO.
QTY MATERIAL DESCRIPTION MAN. CAT. NO.
C1 725' CONDUCTOR, 2" IPS, SCH-40, AL, 6063-T6, 1020A, 2.375 O.D. AFL 200S40YT6BC2 450' CONDUCTOR, 477MCM ACSR, 26/7, 523A, .858" O.D., 565LB/1000FT SOUTHWIRE HAWKC3 65' CONDUCTOR, TREE WIRE, 15kV, 1/0 ACSR, 6/1, .698 O.D., 264LB/1000FT HENDRIX TREE WIREC4 30' CONDUCTOR, #2, 7 STRAND AAC, 138A, .292" O.D., 62LB/1000FT, TREE WIRE HENDRIX TREE WIREC5 150' CONDUCTOR, TREE WIRE, 35kV, 477 ACSR, 26/7, .858" CONDUCTOR O.D., 1.498 CABLE, O.D., 1179LB/1000FT HENDRIX TREE WIREC6 15 TERMINAL, AL, COMPRESSION, 477MCM ACSR CABLE TO FLAT 4 HOLE PAD ANDERSON CCLS-883-C
C6A 3 TERMINAL, AL, COMPRESSION, 477MCM ACSR CABLE TO 4 HOLE PAD, 90 DEG ANDERSON CCLS-883-C-Y90C7 3 TERMINAL, AL, COMPRESSION, 477MCM ACSR CABLE TO 2 HOLE PAD 90 DEG ANDERSON CCLS-883-B2-Y90C8 81 TERMINAL, AL, COMPRESSION, 477MCM ACSR CABLE TO 2 HOLE PAD FLAT ANDERSON CCLS-883-B2C9 16 TERMINAL, AL, COMPRESSION, 1/0 ACSR CABLE TO 2 HOLE PAD FLAT ANDERSON CCLS-398-B
C10 CONNECTOR, AL, BOLTED, TEE, 795MCM ACSR CABLE RUN TO #4 SOL-4/0 ACSR CABLE TAP ANDERSON ATCC-136C10A CONNECTOR, AL, BOLTED, TEE, 477MCM ACSR CABLE RUN TO 477MCM ACSR CABLE TAP ANDERSON ATCC-99C11 TERMINAL, AL, WELDED, 2" IPS TO 4 HOLE PAD FLAT ANDERSON WSTF-20-CC12 TERMINAL, AL, COMPRESSION, #2 AAC CABLE TO 2 HOLE PAD FLAT ANDERSON CCLS-325-BC13 TERMINAL, AL, WELDED, 2" IPS TO 2 HOLE PAD FLAT ANDERSON WSTF-20-B2-CFC14 25 TERMINAL, AL, WELDED, 2" IPS TO 2 HOLE PAD 90 DEG. ANDERSON WSTF-20-B2-Y90
C14A 3 TERMINAL, AL, WELDED, 2" IPS TO 4 HOLE PAD 90 DEG. ANDERSON WSTF-20-C-Y90C15 36 TERMINAL, AL, WELDED, TEE, 2" IPS TO 2 HOLE PAD FLAT ANDERSON WTTFR-10-24-B2C16 24 CONNECTOR, AL, WELDED, 45°, 2" IPS TO 2" IPS ANDERSON WTT-2020C17 6 TERMINAL, AL, WELDED, TEE, 2" IPS TO 4 HOLE PAD FLAT ANDERSON WTTFR-10-24-CC18 3 TERMINAL, AL, BOLTED, TEE, 1/0 ACSR TO 4 HP ANDERSON ATCF-630-1C19 AS REQ'D COUPLER, AL, WELDED, 2" IPS TO 2" IPS STRAIGHT ANDERSON WC-2020C20 COUPLER, AL, WELDED, 2" IPS TO 2" IPS 90 DEG. ANDERSON WLI90-2020C21 42 SUPPORT, AL, WELDED/SLIP, 2" IPS TO 3" BOLT CIRCLE ANDERSON WTH-20-3C22 6 SUPPORT, AL, WELDED, VERTICAL, 2" IPS TO 3" BOLT CIRCLE ANDERSON WUDE-20-3C23 14 END CAP, AL, WELDED, 2" IPS ANDERSON ACB-20C24 3 SUPPORT, AL, BOLTED, HORIZ, 477MCM ACSR TO 5" B.C. ANDERSON ACS-9-5C25 6 SUPPORT, AL WELDED, EXPANSION, HORIZ, 2" IPS TO 3" BOLT CIRCLE ANDERSON AURF-20-3C26 TERMINAL, CU, TINNED, COMPRESSION, 500MCM CU CABLE TO FLAT 4 HOLE PAD ANDERSON CHLN-500-CC27 TERMINAL, CU, TINNED, COMPRESSION, 500MCM CU CABLE TO FLAT 2 HOLE PAD ANDERSON CHL500BNC28 6 TERMINAL #2 TO 2 HOLE PAD ANDERSONC30 120' CONDUCTOR 795 MCM AAC 690 AMPS ANDERSONC31 9 TERMINAL, AL, COMPRESSION, #795 AAC TO 4 HOLE PAD ANDERSONC32 3 TERMINAL, AL, COMPRESSION, #795 AAC TO 4 HOLE PAD, 90° PAD ANDERSONC33 TERMINAL, AL, COMPRESSION, #795 AAC TO 2 HOLE PAD ANDERSONC40 3 CONDUCTOR, CU BRAID, TINNED, 774 AMPS (V-SW TO BUS), 21" ANDERSON
FB-600-21
C41 3 CONDUCTOR, CU BRAID, TINNED, 774 AMPS (BUS TO CT-H1), 50" ANDERSONFB-600-50
C42 3 CONDUCTOR, CU BRAID, TINNED, 774 AMPS (BUS TO CT-H2), 42" ANDERSONFB-600-42
OR
IG
IN
AL
IS
SU
ED
KD
JM
BA
PG
01
/2
4/2
0
41
9-8
21
RE
LE
AS
E F
OR
B
ID
JA
MC
TW
B5
/2
9/2
02
0
41
9-8
21
COMM./SCADA PANEL
CONDUITS (2)
LOW SIDE SUPPORT
STEEL PLATE WELDED
ON LEG FOR BOX
ANTENNA INSTALLATION DETAIL
JUNCTION BOX, FOR MOUNTING
℄ 26.25" X 19.5". PANEL SHOWN
BELOW
MATERIAL NOTE:
ITEM 23 - FUSE BLOCKS
ITEM 25 - TERMINAL BLOCKS
\\E
SC
-D
C2\P
RO
JE
CT
S\400'S
\419\821-C
IT
Y O
F G
LE
NW
OO
D S
PR
IN
GS
-G
LE
ND
WO
OD
S
PR
IN
GS
E
LE
CT
RIC
T C
AR
DN
ELL S
UB
ST
AT
IO
N\D
RA
WIN
GS
\C
N-W
200.D
WG
C
ody T
erkhorn 8 June 2020
8:20:03 A
M
CIT
Y O
F G
LE
NW
OO
D S
PR
IN
GS
GLE
NW
OO
D S
PR
IN
GS
, C
OLO
RA
DO
CA
RD
NE
LL S
UB
ST
AT
IO
N
CO
MM
UN
IC
AT
IO
N A
ND
R
ELA
Y P
AN
EL E
LE
VA
TIO
N
CN-W200
No
Draw
nD
ate
Revisions
Designed
Checked
APPROVED BY:
Proj. N
o.
JMB
765432
1
0
Not For Construction
RELEASE
FOR BID
8-Jun-20
BILL OF MATERIAL
ITEM NO. DEVICE SYMBOL MFGR. TYPE STYLE OR CAT. NO. QTY DESCRIPTION AND RATING
1 NOT USED
2 NOT USED
3 NOT USED
4 COMM SEL 35304BB0XX211X0XXXXXX 1 REAL-TIME AUTOMATION CONTROLLER, COMMUNICATIONS PROCESSOR W/4 SERIAL CONNECTIONS
5 SEL 2812 SEL 2812MRX0 2 FIBER OPTIC TRANSCEIVER WITH IRIG-B
6 110FX2 NTRON 110FX2-ST 1 UNMANAGED INDUSTRIAL NETWORK SWITCH
7 104TS NTRON 104TX 1 UNMANAGED INDUSTRIAL ETHERNET SWITCH
8 RMAD Hammond RMAD19003BK 1 HAMMOND RAIL MOUNT ADAPTER, ADJUSTABLE DEPTH DIN RAIL
9 S8VK OMRON S8VK-G06012 1 SWITCH MODE POWER SUPPLY, 12VDC, 4.5A
10 BREAKER AMERICAN ELECTRICAL C10A1P-489 3 AMERICAN ELECTRICAL DIN RAIL BREAKER, UL 489 RATED
11 DDB UNLIMITED OD-30DXC 1 15U OUTDOOR 19" DOUBLE DOOR ENCLOSURE, NEMA 4X, FLAT ALUMINUM FINISH, ALUMISHIELD, MOUNTING
BRACKETS
12 HEATER DDB UNLIMITED HT-300 1 300W INTERNAL HEATER
13 RECST TRIPP-LITE RS-0615-R 6 OUTLET RACK POWER STRIP, OR APPROVED EQUAL PROVIDED IS IT SURGE PROTECTED AND INCLUDES A
SWITCH
14 TB1 & TB3 GE EB25B12 2 TERMINAL BLOCK, TYPE EB-25, 12 POLE, 600 VOLT, 30 A, #10 SCREW TERMINAL
15 TB2S & TB4S GE EB27B12 2 TERMINAL BLOCK, SHORTING, TYPE EB-27, 12 POLE, 600 VOLT, 30 A, #10 SCREW TERMINAL
16 CABLES TO GO 03864 1 1U 24-PORT SHIELDED PATCH PANEL
17 BELDEN 7921A BY FOOT BELDEN CAT5E DATA CABLE - OUTDOOR RATED AND SHIELDED
18 PANDUIT ISTPHCH0.3MYL 6 CAT5E PATCH CABLES - SHIELDED @ 1 FT
19 PANDUIT ISTPHCH0.6MYL 2 CAT5E PATCH CABLES - SHIELDED @ 2FT
20 PANDUIT F6D2-2M1Y 3 MULTIMODE ST-ST FIBER PATCH CABLES, @ 3 FT
21 FU1, FU2,
FU3, FU4
USD H25030-2S 2 BLOCK 4-POLE, 30A, 250V FUSE BLOCK (TWO USD #H25030-2S PER BLOCK) 5 AMP FUSES W/NEUTRAL SLUG
22 NOT USED
23 RMFU1,RMFU2 AMERICAN ELECTRICAL ASK4LD #351729 2 24V FUSE BLOCK 1-1/4"x1/4"
24 RAIL END AMERICAN ELECTRICAL #495049 1 RAIL END BRACKET/COVER FOR FUSE BLOCKS
25 RTBP, RTBN AMERICAN ELECTRICAL #304120 10 RAIL MOUNT TERMINAL BLOCKS
26 RTXCP, RTXCN AMERICAN ELECTRICAL #474129 1 TERMINAL BLOCK CROSS CONNECTOR (TO BE CUT IN HALF)
27 RTBN END AMERICAN ELECTRICAL #444120 1 END PLATE
NAMEPLATE ENGRAVING SCHEDULE - COM. SCADA PANEL
NP
NO.
SIZE
WxL (In)
LTR.
SIZE
FIRST LINE ENGRAVING
LINE
LENGTH
LTR.
SIZE
SECOND LINE ENGRAVING
LINE
LENGTH
LTR.
SIZE
THIRD LINE ENGRAVING
LINE
LENGTH
NP
QTY.
ENGRAVING INSTRUCTIONS
1 1 x 4 4 SEL 735A 1.3 4POWER QUALITY METER
3.2 0.0 1
2
3 2 X 6 4 SEE BELOW 1.5 4 0.0 0.0 1 1. ALL NAMEPLATES SHALL BE
4 1 x 2 4 COMM 0.7 4 SWITCH 1.0 0.0 1 MOUNTED TO PANELS USING
5 SCREWS.
6 1 x 2 4 110FX2 1.0 4 0.0 0.0 1 2. NAMEPLATES SHALL BE MADE
7 1 x 2 4 104TX 0.8 4 0.0 0.0 1 OF 1/16" THICK PHENOLIC
8 1 x 2 4 REDLION 1.2 4 16DI24 1.0 0.0 1 MATERIAL WITH WHITE LETTERS
9 1 x 2 4 S8VK 0.7 4 0.0 0.0 1 ON A BLACK BACKGROUND.
10 1 x 2 4 BREAKERS 1.3 4 0.0 0.0 13. NAMEPLATE SIZE AS REQ'D TO LINE
11 UP WITH TEST BLOCK SWITCH POLES.
12 4. TEST SWITCH LAYOUT WILL BE
13 1 X 2 4 RECST 0.8 0.0 0.0 1 PROVIDED WITH AC/DC SCHEMATIC.
14 1 x 2 4 TB1 0.5 0.0 0.0 2
15 1 X 2 4 TB2S 0.7 0.0 0.0 2 LETTERS
16 1 X 2 4 TB3 0.5 SIZE
HEIGHT (IN)
NO/IN
17 1 X 2 4 TB4S 0.7 1 1/8 10
18 2 5/32 7.5
19 3 3/16 7.5
20 4 1/4 6
21 5 5/16 3.75
22 6 3/8 3
23 7 1/2 2.25
24 8 3/4 2
25 9 1 1.5
26 * DIM AS REQ'D TO LINE UP WITH TEST
27 BLOCK SWITCH POLES.
28
TEST SWITCHA B C D E F G H I J
NP3LINE 1 TS-FT1LINE 2 12.5kV PT 12.5kV CT PTLINE 3 VA VB VC IA IAR IB IBR IC ICR VN
OR
IG
IN
AL
IS
SU
ED
KD
JM
BA
PG
41
9-8
21
OR
IG
IN
AL
IS
SU
ED
KD
JM
BA
PG
10
/3
1/1
9
41
9-8
21
P
E
N
D
I
N
G
F
I
N
A
L
D
E
S
I
G
N
RE
LE
AS
E F
OR
B
ID
JM
BD
KD
AP
G0
6/0
1/2
0
41
9-8
21