2
6 6 The manufacturer reserves the right to discontinue or change specifications or designs at any time without notice and without incurring obligations. Flammable cabinets Corrosive cabinets Toxic cabinets and multirisk Pesticide range Fume hoods, filtering cabinets - Ventilation Containment and Cans Anti-fire quipments and File cabinets Showers and first- aid quipments 6 REGULATIONS FM(FACTORY MUTUAL): Offers worldwide industrial and commercial product certification and testing services throught its business unit FM Approvals. Recognized and respected across the globe, FM approvals certification assures customers that a product has been objectively tested and conforms to the hightest national standards. The FM certification requires a fire-resistance of 10 minutes for Safety cabinets, according to the heating curve NFPA 251-1969. EUROPEAN NORM EN 14470-1: It is applicable for storage of flammable and highly flammable chemicals in a laboratory. The flammables used in laboratories must be stored in one or several safety cabinets which are fire resistant 15 (minimum required),0,60 or 90 minutes. EUROPEAN NORM EN 14470-2: It is applicable for storage of gas cylinders in laboratories. The gas cylinders used in laboratories must be stored in one or several safety cabinets which are fire resistant 15 (minimum required),0,60 or 90 minutes. NF X 15-211 - MAI 2009 NORM: The standard indicate on the ventilation and filtration efficiency, as well as the Containment efficiency for the recirculatory fume hood designed for chemicals use in laboratories. EUROPEAN NORM EN 1869-1997: This norm indicates that a fire blankets must be able to resist to a heat 900°C done by a fresh fuel oil (such as edible soya bean oil or rapaseed oil). The electric resistance must not be below 1 Ohm. EUROPEAN NORM EN ISO 1182: Indicates the test for the non flammables buiding materials (Thermic insulation). EUROPEAN NORM EN 15154-1 AND EN 15154-2: This regulation concerns first aid equipment and especially body showers and eye-washers, connected to water network. NT FIRE 017: Swedish standard in as per the market of cabinets to store documents and IT furnitures. sorts of fire resistance : 0,60, and 90 minutes. 08/2015 EN 14470-1 NF X 15-211 EN 1869-1997 ISO 1182 EN 15154-1 / 2 NT Fire 017 EN 14470-2 GHS - Globally Harmonized System of Classification and Labelling of Chemicals (only concers the safety container of the chemical itself, do not apply to safety storage cabinets : is an internationally agreed-upon system, created by the United Nations. It supersedes the relevant system of the European Union, which has implemented the United Nations’ GHS into EU law as the CLP Regulation and United States Occupational Safety and Health Administration standards. Not to be confused with ISO 7010 and ISO 864. ISO 7010/ISO 3864 (Relates to the labelling affixed to the safety cabinets) : The ISO 7010 prescribes the safety signs to be used in the context of accident prevention, fire fighting and information on the risks of health’s damages. The shape and color of each safety signs and the design of the graphic symbols conform to ISO 864. ISO 7010 / 3864 GHS

reGulaTIoNs - Trionyx

  • Upload
    others

  • View
    2

  • Download
    0

Embed Size (px)

Citation preview

Page 1: reGulaTIoNs - Trionyx

66

The

man

ufac

ture

r res

erve

s th

e rig

ht to

dis

cont

inue

or c

hang

e sp

ecifi

catio

ns o

r des

igns

at a

ny ti

me

with

out n

otic

e an

d w

ithou

t inc

urrin

g ob

ligat

ions

.

Flam

mab

leca

bin

ets

Co

rro

sive

cab

inet

sTo

xic

cab

inet

san

d m

ult

iris

kPe

stic

ide

ran

ge

Fum

e h

oo

ds,

filte

rin

gca

bin

ets

- Ven

tila

tio

nC

on

tain

men

tan

d C

ans

Ant

i-fire

qui

pm

ents

and

File

cab

inet

sSh

ow

ers

and

firs

t-ai

d q

uip

men

ts

6

reGulaTIoNs

FM(FAcTory MUTUAL): Offers worldwide industrial and commercial product certification and testing services throught its business unit FM Approvals. Recognized and respected across the globe, FM approvals certification assures customers that a product has been objectively tested and conforms to the hightest national standards. The FM certification requires a fire-resistance of 10 minutes for Safety cabinets, according to the heating curve NFPA 251-1969.

EUropEAN NorM EN 14470-1: It is applicable for storage of flammable and highly flammable chemicals in a laboratory. The flammables used in laboratories must be stored in one or several safety cabinets which are fire resistant 15 (minimum required),�0,60 or 90 minutes.

EUropEAN NorM EN 14470-2: It is applicable for storage of gas cylinders in laboratories. The gas cylinders used in laboratories must be stored in one or several safety cabinets which are fire resistant 15 (minimum required),�0,60 or 90 minutes.

NF X 15-211 - MAi 2009 NorM: The standard indicate on the ventilation and filtration efficiency, as well as the Containment efficiency for the recirculatory fume hood designed for chemicals use in laboratories.

EUropEAN NorM EN 1869-1997: This norm indicates that a fire blankets must be able to resist to a heat 900°C done by a fresh fuel oil (such as edible soya bean oil or rapaseed oil). The electric resistance must not be below 1 Ohm.

EUropEAN NorM EN iso 1182: Indicates the test for the non flammables buiding materials (Thermic insulation).

EUropEAN NorM EN 15154-1 AND EN 15154-2: This regulation concerns first aid equipment and especially body showers and eye-washers, connected to water network.

NT FirE 017: Swedish standard in as per the market of cabinets to store documents and IT furnitures. � sorts of fire resistance : �0,60, and 90 minutes.

08/2

015

eN 14470-1

Nf X 15-211

eN 1869-1997

Iso 1182

eN 15154-1 / 2

NT fire 017

eN 14470-2

GHs - Globally Harmonized System of Classification and Labelling of Chemicals (only concers the safety container of the chemical itself, do not apply to safety storage cabinets : is an internationally agreed-upon system, created by the United Nations. It supersedes the relevant system of the European Union, which has implemented the United Nations’ GHS into EU law as the CLP Regulation and United States Occupational Safety and Health Administration standards. Not to be confused with ISO 7010 and ISO �864.

Iso 7010/iso 3864 (Relates to the labelling affixed to the safety cabinets) : The ISO 7010 prescribes the safety signs to be used in the context of accident prevention, fire fighting and information on the risks of health’s damages. The shape and color of each safety signs and the design of the graphic symbols conform to ISO �864.

Iso 7010 / 3864

GHs

Page 2: reGulaTIoNs - Trionyx

77

The

man

ufac

ture

r res

erve

s th

e rig

ht to

dis

cont

inue

or c

hang

e sp

ecifi

catio

ns o

r des

igns

at a

ny ti

me

with

out n

otic

e an

d w

ithou

t inc

urrin

g ob

ligat

ions

.

Flam

mab

leca

bin

ets

Co

rro

sive

cab

inet

sTo

xic

cab

inet

san

d m

ult

iris

kPe

stic

ide

ran

ge

Fum

e h

oo

ds,

filte

rin

gca

bin

ets

- Ven

tila

tio

nC

on

tain

men

tan

d C

ans

Ant

i-fire

eq

uip

men

tsan

d F

ile c

abin

ets

Sho

wer

s an

d fi

rst-

aid

eq

uip

men

ts

7

sTIcKer reGulaTIoNs aND cHeMIcals INcoMPaTIBIlITIes

+ Compatible products - Non compatible products

The sticker on your cans is you must store them in a safety cabinet/compartment for

chemicals incompatibilities

Flammables + - - O +Corrosives - O - O O

Toxics

- - + + OC.M.R products

Environmental hazards

Healthcare hazards/Irritants - NoxiousO - + + ++ O O + +

O Do not store, handle or waste together except if particular conditions are applied

Xn

Xn

Xn

Xi

Xn

Xn

Xn

Xi

you need a clear and understandable information to install our cabinets, fume hoods or

filtration boxes?Consult all our tutorials in video and much more on...

www. http://www.ecosafesa.com/fr/videos.php 04

/201

7