2
Some references of installed filters Updated february 6th, 2017 WELL-WATER. Normandie forage, Verson (France). Prago filters and Alfa hydro- cyclones for several applications of house well-water filtration. Hervé Thermique, Châlons en Champagne (France). Prago filter (100 microns filtration) used to protect a geothermal heatpump. CCF, Valbonne (France). In a private property, garden spraying network filtration. 2 filters AG200 3’’ IP65 PN10 60 microns. Auto Lavage 83, Draguignan (France). Well-water filtration, used to supply a carwash. Prago filter. Siagro, Diass (Senegal). Sand-laden (100 mg/L) well-water treat- ment through Alfa300 hydrocyclone. SCEA Cantou, Nousty (France). Treatment of dust-laden well-wa- ter, used to water livestock. Filter AG100 40µm. Camping du domaine de Massereau (France). For showers wa- ter supply, AG300 filters have been installed to reduce turbidity of a water contaning clay. 2 filters AG300 3’’ 6 microns. Maximum flow rate of 45 m³/h. Hectron filters REFERENCES Clay-laden well-water filtration, to protect geothermal heatpump ex- changers. Filter AG400 DN100 1µm. ATIEP, Lilly France factory, Fegersheim (France). Well-water treatment, in protection of a water cooling system. 3 filters AS300 DN150 60µm. Flow rate : 120 m 3 /h per filter. Spie Batignolles Energies. A geothermal plant with well-water has been installed at CCLF, Livarot (France). To protect the heat exchan- gers, an AS200 60µm filter as been setup. Max flow rate of 45 m³/h. POTABLE WATER. Stereau, Ste Cécile (France) potable water treatment plant. HEAT EXCHANGER PROTECTION. Hervé Thermique, Milly la Forêt swiming pool (France). Well-wa- ter filtration to protect a plate heat exchanger. Filter AS200 80 mi- crons. Engie Axima / Romanité museum, Nîmes (France). The heat- pump system is protected by 2 filters AG200 3’’, filtration 200 mi- crons. Tunzini, St Jean de Braye (France). As part of the renovation of a former industrial site, a geothermal heat pump has been installed. Protected by 2 filters AS300 DN150 80 microns. Suez Lyonnaise des eaux, Rouen (France). Ground water heat- pump, for a building heating system. Filtration 100µm. 2 Filters AS300 DN150. BBS Maintenance / Colas, Magny les Hameaux (France). Water filtration, to protect ultrafiltration membranes. Flow rate: 211 m 3 /h. Supply of one filter AG400-E DN250 with 200µm. Matec, Libreville, Gabon. Filters for Africa Cup of Nations 2017 buildings water supply. Filters AG300 1 and 6 microns. MT2E, Sillans la Cascade (France). Installation of 1 filter AG100-E for a municipality water supply. Mora Eau et Environnement, Millau (France). Well-water filtration for use as potable water. Flow rate : 8 m 3 /h. Filter AG100-E (ACS certification) 20 µm. Degrémont France, Vierzon (France) potable water plant. Water pre-filtration upstream the treatment plant. 2 filters AG200-E 500µm, with ACS certification. Degrémont France Assainissement, Belle Ile en Mer (France) potable water plant. Water pre-treatment after clarifier-settler. 2 fil- ters AG200-E 316L 400 µm, with ACS certification. Genolhac (France) municipality water administration. Town po- table water network filtration. Filter AG200-E 3’’ 40µm, with ACS cer- tification. WASTEWATER TREATMENT. Veolia OTV, St Clément de Rivière (France) wastewater treat- ment plant. Filtration after a wastewater clarifier-settler. Filter AG200 2’’ 200 µm. Suez (Degremont), Geolide wastewater plant, Marseille (France). Filtration after a wastewater clarifier-settler, filter AG300 316L in 400 microns. Flow rate up to 70 m 3 /h. Suez, Laon (France) wastewater treatment plant. Water filtration after the plant, for industrial use. Low pressure network (less than 0,5 Bar). Filter AS200 500 µm. Veolia Eau, Thônes (France). Water filtration after a wastewater clarifier-settler. Filter AG300 DN80 6µm and sustainer CRF80.

REFERENCES Hectron filters - Filtre pour eau, forage ... · PDF fileSuez (Degremont), Geolide wastewater plant, Marseille (France). ... Veolia Eau, Thônes (France). Water filtration

Embed Size (px)

Citation preview

Page 1: REFERENCES Hectron filters - Filtre pour eau, forage ... · PDF fileSuez (Degremont), Geolide wastewater plant, Marseille (France). ... Veolia Eau, Thônes (France). Water filtration

Some references of installed filtersUpdated february 6th, 2017

WELL-WATER.

Normandie forage, Verson (France). Prago filters and Alfa hydro-cyclones for several applications of house well-water filtration.

Hervé Thermique, Châlons en Champagne (France). Prago filter (100 microns filtration) used to protect a geothermal heatpump.

CCF, Valbonne (France). In a private property, garden spraying network filtration. 2 filters AG200 3’’ IP65 PN10 60 microns.

Auto Lavage 83, Draguignan (France). Well-water filtration, used to supply a carwash. Prago filter.

Siagro, Diass (Senegal). Sand-laden (100 mg/L) well-water treat-ment through Alfa300 hydrocyclone.

SCEA Cantou, Nousty (France). Treatment of dust-laden well-wa-ter, used to water livestock. Filter AG100 40µm.

Camping du domaine de Massereau (France). For showers wa-ter supply, AG300 filters have been installed to reduce turbidity of a water contaning clay. 2 filters AG300 3’’ 6 microns. Maximum flow rate of 45 m³/h.

Hect

ron

filter

s REFERENCES

Clay-laden well-water filtration, to protect geothermal heatpump ex-changers. Filter AG400 DN100 1µm.

ATIEP, Lilly France factory, Fegersheim (France). Well-water treatment, in protection of a water cooling system. 3 filters AS300 DN150 60µm. Flow rate : 120 m3/h per filter.

Spie Batignolles Energies. A geothermal plant with well-water has been installed at CCLF, Livarot (France). To protect the heat exchan-gers, an AS200 60µm filter as been setup. Max flow rate of 45 m³/h.

POTABLE WATER.

Stereau, Ste Cécile (France) potable water treatment plant.

HEAT EXCHANGER PROTECTION.

Hervé Thermique, Milly la Forêt swiming pool (France). Well-wa-ter filtration to protect a plate heat exchanger. Filter AS200 80 mi-crons.

Engie Axima / Romanité museum, Nîmes (France). The heat-pump system is protected by 2 filters AG200 3’’, filtration 200 mi-crons.

Tunzini, St Jean de Braye (France). As part of the renovation of a former industrial site, a geothermal heat pump has been installed. Protected by 2 filters AS300 DN150 80 microns.

Suez Lyonnaise des eaux, Rouen (France). Ground water heat-pump, for a building heating system. Filtration 100µm. 2 Filters AS300 DN150.

BBS Maintenance / Colas, Magny les Hameaux (France).

Water filtration, to protect ultrafiltration membranes. Flow rate: 211 m3/h. Supply of one filter AG400-E DN250 with 200µm.

Matec, Libreville, Gabon. Filters for Africa Cup of Nations 2017 buildings water supply. Filters AG300 1 and 6 microns.

MT2E, Sillans la Cascade (France). Installation of 1 filter AG100-E for a municipality water supply.

Mora Eau et Environnement, Millau (France). Well-water filtration for use as potable water. Flow rate : 8 m3/h. Filter AG100-E (ACS certification) 20 µm.

Degrémont France, Vierzon (France) potable water plant. Water pre-filtration upstream the treatment plant. 2 filters AG200-E 500µm, with ACS certification.

Degrémont France Assainissement, Belle Ile en Mer (France) potable water plant. Water pre-treatment after clarifier-settler. 2 fil-ters AG200-E 316L 400 µm, with ACS certification.

Genolhac (France) municipality water administration. Town po-table water network filtration. Filter AG200-E 3’’ 40µm, with ACS cer-tification.

WASTEWATER TREATMENT.

Veolia OTV, St Clément de Rivière (France) wastewater treat-ment plant. Filtration after a wastewater clarifier-settler. Filter AG200 2’’ 200 µm.

Suez (Degremont), Geolide wastewater plant, Marseille (France). Filtration after a wastewater clarifier-settler, filter AG300 316L in 400 microns. Flow rate up to 70 m3/h.

Suez, Laon (France) wastewater treatment plant. Water filtration after the plant, for industrial use. Low pressure network (less than 0,5 Bar). Filter AS200 500 µm.

Veolia Eau, Thônes (France). Water filtration after a wastewater clarifier-settler. Filter AG300 DN80 6µm and sustainer CRF80.

Page 2: REFERENCES Hectron filters - Filtre pour eau, forage ... · PDF fileSuez (Degremont), Geolide wastewater plant, Marseille (France). ... Veolia Eau, Thônes (France). Water filtration

Flertex, St Florentin, France. Factory process water filtration. 4 fil-ters AG200 20 µm

SURFACE WATER.

Vicat, Créchy (France) cement factory. Pond water filtration. Wa-ter used in the cement factory process. Flow rate : 110 m3/h. Filter AS300 DN150 200µm.

SHEM, Paulhaguet (France). River water filtration, to protect a small hydroelectric plant. Filter AG100 100µm.

Boccard / Electrabel, Feluy (Belgium). Meuse river filtration, for the factory water supply. 4 filters AG200 2’’ in 6 µm.

Cofely Services / Papeterie des Vosges, Laval sur Vologne (France). Surface water filtration, in order to supply a boiler. Filter AG200 3’’ 20µm

Strelec, Strasbourg (France). Darse channel filtration, to supply water for the process, factory washing and fire protection. 2 filters AG300 DN150 PN10 in 200µm

Cascades paper factory, La Rochette, France. River water filtra-tion, used in the factory process. 4 Filters AG300.

Soletanche, Kentucky (USA).

Dam water filtration, used for drilling hammers operation. Filters AG300 6 µm.

SEAWATER.

Drema Waterbehandeling, Netherlands. Seawater filtration to pro-tect osmosis membranes. 2 filters AG200 316L-C 1 micron.

Ferme Marine du Douhet. Factory in Iran. New water treatment, after pumping. Sand-laden water. Hydrocyclone Alfa 300 Marine.

Atlantique Industrie / Le Havre (France) Congress center. Seawater filtration, to protect plate heat exchangers. 2 filters AS400 316L C, filtration 500 µm.

SLCE, Lanester (France). Filtration of seawater containing sand, through hydrocyclone. Hydrocyclone Alfa 200 1’’ Marine.

Trafordyn, Saint-Nazaire (France). Setting up of a AG200-316L fil-ter after pumping in the ocean, to supply a thalassotherapy center.

HECTRON 25 avenue Pierre Emmanuel - 06000 Nice - [email protected] | www.hectron.com | tel. : +33 (0)4 93 97 02 42 | fax : +33 (0)4 93 84 86 76

Sogea Sud-Ouest Hydraulique, Assat Bondes (France). Indus-trial water filtration after a wastewater treatment plant : filter AG200 DN80 ; filtration 100 μm

SAUR, La Flotte (France).

Filtration downstream a wastewater treatment plant, for a UV treat-ment system protection. Water used for irrigation. AG400-316L DN150 filter, filtration 20 µm, flow rate : 100 m³/h.

Stereau, La Santé wastewater treatment plant, Vitré (France). Fil-tration downstream a clarifier-settler. Filter AG200 3’’ PN10 400µm.

Municipality of Gap (France), waste water treatment plant. In-dustrial water filtration, after clarifier-settler, before washing nozzles. AG200 3’’ 10 Bar filter; 200 µm filtration; flow rate : 35 m³/h.

INDUSTRIAL WATER NETWORKS.

B+W, Bottrop, Germany. Water filtration before high-pressure pumps. Water used in spraying systems. Filters AG200 2’’ 6 microns and CRL50.

Automatisme Industrie / Mecaplast, Lens (France). Cooling network in a plastic factory. A part of the flow-rate is filtered through a branch circuit. Pump + filter AG300 50µm + CRL sustainer.

Periplast, Perigny (France). PVC tubes factory. Cooling closed-cir-cuit filtration. AG300 DN150 100 µm.

Hohn aerodrome, Germany. Water treatment before fire protection water tanks. An AG200 PN10 3’’ 60 microns filter has been supplied, and a CRL80 pressure sustainer.

Morssinkhof Plastic, Zeewolde (Netherlands). Elimination of PET particles in the factory network. AG200 2’’ filter, 40m3/h.

SOTICI, Abidjan, Côte d’Ivoire.

Cooling closed-circuits filtration, on the PVC and PE extrusion units. Total flow rate : 150 m3/h. 2 filters AG300 DN150 200 µm.