    LOSS PREVENTION CERTIFICATION BOARD

    RED BOOK (24 December 2010)

    Volume 1LIST OF APPROVEDPRODUCTS AND SERVICES

    - FIRE DETECTION AND ALARM PRODUCTS & SERVICES- FIRE SUPPRESSION PRODUCTS & SERVICES- RELATED INSTALLERS

     A Specifier’s Guide

  • 8/16/2019 Redbook Vol1part1 2011

    2/389

    CONTENTS

    ii 24 Dec 2010

    1 Fire detection and alarm products, systems & cables 1SECTION 1 LPS 1014 certified fire detection and alarm system firms 3SECTION 2 Fire detection and alarm systems 13SECTION 3 Control and indicating equipment 16SECTION 4.1 Commercial detectors 109

    SECTION 4.2 Domestic alarms - smoke, heat and carbon monoxide 223SECTION 5 Manual call points 227SECTION 6 Line units 252SECTION 7 Alarm Warning Devices 271SECTION 8 Fire resistant cables 308SECTION 9 Alarm receiving centres 377SECTION 10 Alarm transmission and fault monitoring equipment and signalling systems

    379SECTION 10.1 Alarm transmission and fault routing equipment 381SECTION 10.2 Alarm transmission and fault routing equipment and systems 382SECTION 10.3 Signalling systems 384

  • 8/16/2019 Redbook Vol1part1 2011

    3/389

    INDEX

    24 Dec 2010 iii

    2

    2M KABLO SAN. ve TIC. A.S. 310 A AC Electrical Wholesalers Ltd 311 ADI International 110, 252

     ADT Fire and Security 3, 4 Advanced Electronics Limited 17, 111, 227, 253,

    272 Advantronic Systems S.L. 113, 228, 272 AEI Cables Limited 311 Aguilera Electronica S.L 114 Alarm Supply Pte Ltd 115 Alberta Fire & Security Equipment Limited 5 Alpha Fire Services W.L.L. 316 AMPAC Europe Limited 18 AMPAC Technologies PTY Ltd 19, 228 Apollo Fire Detectors Limited 116, 229, 253, 272 Argus Fire Protection Company Limited 5

     Argus Security S.r.l. 122, 230, 274 Argus-Spectrum Co 124, 230, 274 ATOM KABLO SANAYI VE TICARET A.S. 316 Autronica Fire & Security AS 255, 275BBailey Maintenance 5Bangkok Cable Co Limited 317Banham Alarms (Prop

    Banham Patent Locks Limited) 377Bardic by Honeywell 20, 126BBC Fire Protection Limited 5Beijing Leader Huaxin Electronics Co. Ltd 127Bentel Security s.r.l. 230

    BT Redcare 382, 384CCarillion 21Cavicel SpA 318CEAG 22Ceasefire Industries Ltd 127, 231, 276Chubb Fire Limited 5Chubb Fire Ltd 128, 255Chubb Sécurité 23Clymac Limited 6Computionics Limited (Trading as C-Tec) 24Context Plus Ltd 231, 319Control Equipment Limited 13, 31

    Cooper Controls Limited (trading as IntegratedSolutions) 6

    Cooper Fire Systems 129Cooper Fulleon Limited 231, 277Cooper Industries Inc 33, 130, 232Cooper Lighting and Safety Ltd 35Cooper Safety 131Cranford Controls Limited 278CSL DualCom Limited 383CTM Fire and Security Limited (Leyland & London

    Offices) 6DDaemon Fire and Security Limited 6

    Dätwyler Cables 320Defensor Group Limited 6

    Detector Electronics Corporation 36, 133, 256Digital Security Controls, a Division of Tyco Safety

    Products Canada Ltd 223Direction Fire Limited 7Doncaster Cables 321

    Draka UK Limited 322Dubai Cable Company (Private) Limited 326Dubai Cable Company (Private) Limited, Trading

    as Ducab 327, 328EEland Cables 330EMCO 134, 232, 278EMCOR Facilities Services Limited, EMCOR

    Specialist Services 7EMCS - East Midlands Central Station Limited 377Emergi-Lite Safety Systems (Thomas & Betts Ltd)

    136, 233, 256Emirates Fire Fighting Equipment Factory L.L.C.

    (FIREX) 137, 233, 279, 331Eurotech Fire Systems Ltd 138Everday Technology Co. Limited 139, 233Eyston Company Ltd 224FFFE Fire & Security Limited 7FireAngel Ltd (A Division of Sprue Aegis plc) 224Fireguard Safety Equipment Co Ltd 38, 140, 234,

    279Firelite by Honeywell 39Fireonica Co. Ltd 141, 234Firetecnics Systems Limited 7FIREX Protection System Technology Ltd 40, 141,

    234, 257, 279GGE Security BV 257GE Security Inc 257GE Security Inc (Trading As Edwards System

    Technology) 142, 258, 280Gent By Honeywell 41, 144, 235, 259, 280Global System Technology Plc 45, 147, 235, 259,

    281, 331Grainger Fire Systems 7Group 4 Securicor Plc 47, 148, 236, 259, 281Grupo General Cable Sistemas, S.A. 332, 333Gulf Security Technology Co. Ltd (Manufacturing

    Division of Global System Technology PLC) 49,149, 236, 260, 282

    HHaes Systems Limited 50Hall & Kay Fire Engineering (Thame) 8Hallmark Fire (a division of Chubb Systems

    Limited) 8HDR 150, 236, 260, 282Hochiki Corporation 151Hochiki Europe (UK) Limited 152, 237, 260, 285Honeywell Automation (I) Pvt. Ltd 156Honeywell Control Systems Limited 156, 261Honeywell Control Systems Ltd 51, 159, 237, 261

    Honeywell International Inc 56Horing LIH Industrial Co Ltd 160, 238, 293

  • 8/16/2019 Redbook Vol1part1 2011

    4/389

    INDEX

    iv 24 Dec 2010

    Hosiden Besson Limited 293Huzhou Jiusheng Electric Co Ltd 334II.C. Service & Maintenance Limited 8Industrial Scientific Oldham 161INIM Electronics s.r.l. 162, 262

    Irish Driver-Harris Company Limited 335JJaylow Supplies Ltd 340KKAC Alarm Company Limited 238, 294Keystone Electric Wire & Cable Company Ltd 341Kidde Finland Oy 225Kidde Products Ltd 164Kidde Products Ltd, trading as AirSense

    Technology 165Kidde Safety Europe Ltd 225Kingfell Plc 8Kingfisher Security (UK) Limited trading as

    Kingfisher Fire & Security 8KME Italy SpA 342L

    Labor Strauss Sicherungsanlagenbau GmbH 242LEONI Studer AG 343Lichfield Fire & Safety Equipment Co. Ltd 166MM. J. Quinn Integrated Services Limited 8, 9Mavili Elektronik Ticaret Ve Sanayi A.S. 167MECE Fire & Security Limited 9Mercury Engineering 9MGC Systems Corp. 242MITIE Technical Facilities Management Limited 9

    MITIE Technical Facilities Management Limited(MITIE Fire and Security Systems) 9

    Morley-IAS Fire Systems By Honeywell 58, 167,170, 243, 262, 297

    MSA AUER 170Multron Systems Pte Ltd 65, 172, 243, 262, 298N

    National Monitoring (Prop. AVR Group Limited)378Nexans France S.A.S.- Lyon Plant 348Nexans Turkiye Endustri ve Ticaret A.S. 349Niscayah Limited 9Nitin Ventures FZE 66, 173, 244, 263Nittan (UK) Limited 174

    Nittan Fire Protection (Zhongshan) Co Ltd 175Notifier by Honeywell 244, 298Notifier Fire Systems by Honeywell 15, 67, 176,

    263Notifier Fire Systems India 179OOG Elektronik 180, 245, 299Olympia Electronics S.A. 75PPEL Services Limited 10Pelco Finland Oy 76, 181, 264Philton Fire & Security Limited 183Photain Controls 183

    Pittway Tecnologica Srl. 184, 264Plana Fabrega 188, 189

    Protec Fire Detection plc 10, 78, 190, 245, 264,300

    Prysmian Cables & Systems Limited 351Prysmian Cables & Systems Ltd 352Prysmian Power Cables & Systems Australia Pty

    Limited 359

    RRAMCRO S.p.A 361Ravel Electronics Pvt. Ltd 194Raysil Security Systems Limited 10SSafety Technology International (Europe) Limited

    245Safex Fire Services Limited 194Sareme UAB 195, 246Scotshield Limited 10Security Services (Prop

    Bryan Enterprises Ltd.) 378Sensor Highway Limited (trading as Sensa) 195

    SHIELD FIRE, SAFETY & SECURITY LTD 82,196, 246, 265, 300, 362

    Siemens plc, Building Technologies, Fire SafetyDivision 11

    Siemens Switzerland Limited, BuildingTechnologies Division 83, 197, 246, 265, 301

    SMS 87, 201, 247, 267Southern Monitoring Services Limited 378Spectrex Inc 202Static Systems Group Plc 11Sterling Safety Systems 204, 248, 302Suzhou Cableplus Technologies Co., Ltd. 363Synaps Technology Srl 248

    System Sensor 206System Sensor Europe 302System Sensor, Honeywell International (I) PVT.

    Limited 206TT V F (UK) Limited 11Tai Sin Electric Limited 363Talentum Developments Limited 209Teledata S.r.l. 209, 248, 303TELE-FONIKA Kable Sp. z o.o., S.K.A. 364Texecom Ltd 304Thameside Fire Protection Co. Limited 11Thorn Security Limited 211

    Thorn Security Limited, Trading as Tyco SafetyProduct 89

    Thorn Security Limited, trading as Tyco SafetyProducts 212, 249, 267, 305

    Tratos Cavi SpA 367Trinity Protection Systems Limited 11, 12Tyco Fire and Integrated Solutions (the trading

    company for Tyco Fire and Integrated Solutions(UK) Limited and Tyco Fire and IntegratedSolutions (Ireland) Limited) 12

    Tyco Thermal Controls Canada Limited 368Tyco Thermal Controls Huzhou Co Limited 369Tyco Thermal Controls UK Ltd 372

    UUnion Cable Company Ltd 373

  • 8/16/2019 Redbook Vol1part1 2011

    5/389

    INDEX

    24 Dec 2010 v

    UTC Fire & Security (Africa) trading as Ziton 15,99, 215, 268

    UTC Fire & Security (Pty) LTD Trading as Ziton249

    UTC Fire & Security Americas Corporation, Inc.105, 216, 250, 268

    UTC Fire & Security BV 250, 269VVentcroft Limited 374Vimpex Limited 269, 307

    Vipond Fire Protection Limited 12Visonic 225VRC Terofire Products 217WWrexham Mineral Cables 375X

    Xtralis Pty Limited 106, 217ZZeta Alarm Systems by GLT Exports Limited 107,

    222, 307, 376

  • 8/16/2019 Redbook Vol1part1 2011

    6/389

  • 8/16/2019 Redbook Vol1part1 2011

    7/389

    Part

    1

    FIRE DETECTION AND ALARM PRODUCTS,SYSTEMS & CABLES

  • 8/16/2019 Redbook Vol1part1 2011

    8/389

    PART 1: FIRE DETECTION AND ALARM PRODUCTS, SYSTEMS &CABLES

    2 24 Dec 2010

    Introduction

     A working fire detection and alarm system will increase the level of safety in a building by automaticallywarning occupants of fire before they would otherwise detect it..

    To ensure the system works, the system must be designed correctly, products must be correctly selected andthe systems must be correctly installed and maintained. It is recommended that all systems are designed,installed, commissioned and maintained by contractors who are approved by LPCB to LPS 1014 and that theyare connected to Alarm Receiving Centres approved to LPS 1020.

    Listings in this section include:

    Products

    Control & indicating equipment and power supplies

    Flame, beam, aspirating, smoke, heat and multi-sensor detectors

    Manual call points

    Line units Sounders

    Cables

     Alarm transmission equipment

    Signalling systems

    Products are approved in accordance with a range of standards. The details of these standards are given atthe front of each section relevant to the product.

    SystemsFire detection and alarm systems are approved for system compatibility in accordance with:

    LPS 1054: Requirements and testing procedures for the approval and listing of componentcompatibility for fire detection and alarm systems.

    EN 54 - Part 13: Compatibility assessment for system components.

    Design, installation, commissioning and maintenance contractors .Contractors are approved in accordance with:

    LPS 1014: Requirements for certificated fire detection and alarm system firms.

    LPS 1020 - Alarm Receiving Centres

  • 8/16/2019 Redbook Vol1part1 2011

    9/389

    PART 1: SECTION 1LPS 1014 CERTIFIED FIRE DETECTION AND ALARM SYSTEM FIRMS

    24 Dec 2010 3

    WHY USE AN LPS 1014 APPROVED COMPANY?

    Even with the best equipment, fire detection and alarm systems are only effective if correctly designed,installed, commissioned and serviced. It is therefore important that specifiers select only competent firms with

    a proven track record to undertake the work.

    LPS 1014 Requirements for Certificated Fire Detection and Alarm System Firms meets these requirements infull.

    LPS 1014 requires one encompassing Certificate of Conformity for the project, i.e. single point responsibility,which benefits all parties concerned, i.e. the insurer, the fire brigade, the building owner, etc. It is based on BS5839-1 and also requires the use of third party approved products. For each system specifiers should requestthe issue of an LPCB Certificate of Conformity as part of the contract which:

    certifies that the fire detection and alarm system was designed, installed and commissioned inaccordance with the installation rules applied, and

    ensures that the system is recorded by LPCB as a certificated fire detection and alarm installation.

    The availability of more varied and sophisticated fire detection and alarm equipment means that it is evenmore important that firms listed to LPS 1014 are regularly assessed by LPCB for their competence to design,install, commission and service fire detection and alarm systems in accordance with acceptable installationrules or codes of practice.

     Addi tional off ices

    Where a firm has additional offices, each office must meet the requirements of LPS 1014 to be eligible forcertification, and is separately listed.

    Provisional Approval

    Firms with limited experience and track record can gain Provisional Approval in the LPS 1014 scheme. Theirwork is closely monitored by LPCB and when they have completed the requisite number of fire detection andalarm systems contracts over a period of not less than 2 years, and subject to satisfactory performance, theywill be given full approval and listed in this section of the Red Book.

     ADT Fire and SecuritySecurity House, The Summit, Hanworth Road, Sunbury on Thames, Middlesex TW16 5DB UKTel: +44 (0)1932 743456 • Fax: +44 (0)1932 743222

    Certifi cate No. CFA-105 to LPS 1014

     ADT Fire and Security ADT House, 5th Avenue Business Park, Team Valley Trading Estate, Gateshead, Tyne and Wear NE11 0HFUKTel: +44 (0)191 451 5000 • Fax: +44 (0)191 487 9543

    Certifi cate No. CFA-111 to LPS 1014

  • 8/16/2019 Redbook Vol1part1 2011

    10/389

    PART 1: SECTION 1LPS 1014 CERTIFIED FIRE DETECTION AND ALARM SYSTEM FIRMS

    4 24 Dec 2010

     ADT Fire and SecurityUnit 5, Redwing Court Business Centre, Ashton Road, Romford, Essex RM3 8QQ UKTel: +44 (0)2082 724700 • Fax: +44 (0)2082 724709

    Certifi cate No. CFA-112 to LPS 1014

     ADT Fire and Security ADT House, Tannochside Park, Uddingston, Glasgow G71 5PH UKTel: +44 (0)1698 486000 • Fax: +44 (0)1698 486100

    Certifi cate No. CFA-113 to LPS 1014

     ADT Fire and SecurityQuay House, City Park Business Village, Manchester M16 9UN UKTel: +44 (0)1612 525500 • Fax: +44 (0)1612 525688

    Certifi cate No. CFA-109 to LPS 1014

     ADT Fire and Security ADT House, Mucklow Hill, Halesowen, Birmingham, West Midlands B62 8DA UKTel: +44 (0)1212 556000 • Fax: +44 (0)1212 556100

    Certifi cate No. CFA-108 to LPS 1014

     ADT Fire and Security180 Aztec West, Almondsbury, Bristol BS32 4TH UKTel: +44 (0)1454 843434 • Fax: +44 (0)1454 843484

    Certifi cate No. CFA-107 to LPS 1014

     ADT Fire and Security1 Bowling Green Terrace, Off Jack Lane, Leeds LS11 9SX UKTel: +44 (0)1132 911000 • Fax: +44 (0)1132 425933

    Certifi cate No. CFA-110 to LPS 1014

  • 8/16/2019 Redbook Vol1part1 2011

    11/389

    PART 1: SECTION 1LPS 1014 CERTIFIED FIRE DETECTION AND ALARM SYSTEM FIRMS

    24 Dec 2010 5

     Alberta Fi re & Secur ity Equipment Limi tedSan Gwakkin Road, Mriehel, BKR 3000, MaltaTel: +356 21 443538 • Fax: +356 21 484077E-mail: [email protected] • Website: www.alberta.com.mt

    Certifi cate No. CFA-177 to LPS 1014

     Argus Fire Protect ion Company Limi tedHendglade House, 46 New Road, Stourbridge, West Midlands DY8 1PA UKTel: +44 (0)1384 376256 • Fax: +44 (0)1384 393955E-mail: [email protected] • Website: www.argusfire.co.uk

    Certifi cate No. CFA-148 to LPS 1014

    Bailey Maintenance7 Brown Lane West, Leeds LS12 6EH UKTel: +44 (0)113 234 3443 • Fax: +44 (0)113 222 3925E-mail: [email protected] • Website: www.baileymaintenance.co.uk

    Certifi cate No. CFA-165 to LPS 1014

    BBC Fire Protection LimitedSt Florian House, Ayton Road, Wymondham, Norfolk NR18 0QH UKTel: +44 (0)1953 857700 • Fax: +44 (0)1953 857750E-mail: [email protected] • Website: www.bbcfire.co.uk

    Certifi cate No. CFA-126 to LPS 1014

    Chubb Fire Limited400 Dallow Road, Luton, Beds LU1 1UR UKTel: +44 (0)1582 413694 • Fax: +44 (0)1582 456353E-mail: [email protected] • Website: www.chubb.co.uk

    Certifi cate No. CFA-121 to LPS 1014

    Chubb Fire Limited5 Canal Place, Armley Road, Leeds LS12 2DU UKTel: +44 (0)113 235 5131 • Fax: +44 (0)113 235 5132E-mail: [email protected] • Website: www.chubb.co.uk

    Certifi cate No. CFA-120 to LPS 1014

  • 8/16/2019 Redbook Vol1part1 2011

    12/389

    PART 1: SECTION 1LPS 1014 CERTIFIED FIRE DETECTION AND ALARM SYSTEM FIRMS

    6 24 Dec 2010

    Clymac LimitedCloudway Court, Belton Road, Loughborough LE11 1LB UKTel: +44 (0)1509 232651 • Fax: +44 (0)1509 232665E-mail: [email protected] • Website: www.clymac.co.uk

    Certifi cate No. CFA-154 to LPS 1014

    Cooper Controls Limited (trading as Integrated Solutions)26 Greenhill Crescent, Watford Business Park, Watford, Hertfordshire WD18 8XG UKTel: +44 (0)1923 495495 • Fax: +44 (0)1923 228796E-mail: [email protected] • Website: www.polaron.com

    Certifi cate No. CFA-162 to LPS 1014

    CTM Fire and Security Limited (Leyland & London Offices)Unit 2, Osprey Place, Moss Side Industrial Estate, Leyland PR26 7EW UKTel: +44 (0)800 5872753 • Fax: +44 (0)1772 641227E-mail: [email protected] • Website: www.firealarmuk.com

    Including the following satellite offices:BBC Television Centre, Arch 118, Dodds Yard, Wood Lane, London W12 7RJTel: +44 (0)208 225 9427 • Fax: +44 (0)208 225 9446

    Certifi cate No. CFA-156 to LPS 1014

    Daemon Fire and Security LimitedDaemon House, 41-42 Albert Road, Tamworth, Staffs B79 7JS UKTel: +44 (0)1827 69266 • Fax: +44 (0)1827 53584E-mail: [email protected]

    Certifi cate No. CFA-145 to LPS 1014

    Defensor Group Limited11-15 Kingsley Street, Leicester LE2 6DY UKTel: +44 (0)116 244 8689 • Fax: +44 (0)116 244 8884E-mail: [email protected]

    Certifi cate No. CFA-161 to LPS 1014

  • 8/16/2019 Redbook Vol1part1 2011

    13/389

    PART 1: SECTION 1LPS 1014 CERTIFIED FIRE DETECTION AND ALARM SYSTEM FIRMS

    24 Dec 2010 7

    Direction Fire LimitedUnits 4 & 5 Fire Quarter, Blenheim Road, Epsom, Surrey KT19 9QN UKTel: +44 (0)1372 744499 • Fax: +44 (0)1372 741188E-mail: [email protected] • Website: www.directionfire.co.uk

    Certifi cate No. CFA-178 to LPS 1014

    EMCOR Facil ities Services Limited, EMCOR Specialist ServicesPremier House, Tollgate, Eastleigh, Hampshire SO53 3YE UKTel: +44 (0)2380 648028 • Fax: +44 (0)2380 648191E-mail: [email protected]

    Certifi cate No. CFA-151 to LPS 1014

    FFE Fire & Security Limited122 The Minories, London EC3 1NT UKTel: +44 (0)845 60 999 06 • Fax: +44 (0)20 8665 4125E-mail: [email protected] • Website: www.ffe.co.uk

    Including the following satellite office at:Unit 20, Tait Road Industrial Estate, Tait Road, Croydon CR0 2DP

    Certifi cate No. CFA-152 to LPS 1014

    Firetecnics Systems Limited142 Vauxhall Street, London SE11 5RH UKTel: +44 (0) 20 7587 0927 • Fax: +44 (0) 20 7582 3496E-mail: [email protected] • Website: www.firetecnics.com

    Certifi cate No. CFA-146 to LPS 1014

    Grainger Fire SystemsThornley House, Carrington Business Park, Carrington, Manchester M31 4XL UKTel: +44 (0)161 777 6700 • Fax: +44 (0)161 777 6638E-mail: [email protected]

    The following location is i ncluded within the scope of certification for servicing:Unit 1A, Newton Court, Wavertree Technology Park, Wavertree, Liverpool L13 1EJTel: +44 (0)151 220 4068 • Fax: +44 (0)151 259 4365

    Certifi cate No. CFA-125 to LPS 1014

  • 8/16/2019 Redbook Vol1part1 2011

    14/389

    PART 1: SECTION 1LPS 1014 CERTIFIED FIRE DETECTION AND ALARM SYSTEM FIRMS

    8 24 Dec 2010

    Hall & Kay Fire Engineering (Thame)Thame Park Road, Thame, Oxfordshire OX9 3RT UKTel: +44(0) 1844 265008 • Fax: +44(0) 1844 265008E-mail: [email protected] • Website: www.hkfire.co.uk

    Certifi cate No. CFA-147 to LPS 1014

    Hallmark Fire (a division of Chubb Systems Limited)Systems House, Stoke Road, Hoo, Rochester, Kent ME3 9NT UKTel: +44 (0)8700 111150 • Fax: +44 (0)8700 111160E-mail: [email protected] • Website: www.hallmarkfire.co.uk

    Certifi cate No. CFA-140 to LPS 1014

    I.C. Service & Maintenance LimitedUnit K3 Temple Court, Knights Park, Knight Road, Strood, Kent ME2 2LT UKTel: +44 (0)1634 290300 • Fax: +44 (0)1634 290700E-mail: [email protected] • Website: www.icservice.biz

    Certifi cate No. CFA-158 to LPS 1014

    Kingfell PlcCapital Tower, 12th Floor, 91 Waterloo Road, London SE1 8RT UKTel: +44 (0)845 60 61 999 • Fax: +44 (0)845 25 81 999E-mail: [email protected] • Website: www.kingfell.com

    Certifi cate No. CFA-138 to LPS 1014

    Kingfisher Security (UK) Limited trading as Kingfisher Fire & Security1 Riverside Industrial Estate, Dogflud Way, Farnham GU9 7UG UKTel: +44 (0)1252 710809 • Fax: +44 (0)1252 710816E-mail: [email protected] • Website: www.kingfishersecurity.co.uk

    Certifi cate No. CFA-176 to LPS 1014

    M. J. Quinn Integrated Services LimitedOak House, Overbrook Lane, Knowsley Business Park, Knowsley, Merseyside L34 9FB UKTel: +44 (0)151 547 8800 • Fax: +44 (0)151 547 8801E-mail: [email protected] • Website: www.mjquinn.co.uk

    Certifi cate No. CFA-137 to LPS 1014

  • 8/16/2019 Redbook Vol1part1 2011

    15/389

    PART 1: SECTION 1LPS 1014 CERTIFIED FIRE DETECTION AND ALARM SYSTEM FIRMS

    24 Dec 2010 9

    M. J. Quinn Integrated Services Limited5th Floor, 119 Farringdon Road, London EC1R 3DA UKTel: +44 (0)207 239 8750 • Fax: +44 (0)207 239 8751E-mail: [email protected] • Website: www.mjquinn.co.uk

    Certifi cate No. CFA-143 to LPS 1014

    MECE Fire & Securi ty Limi tedCourtlodge, Kemsley Street Road, Bredhurst, Gillingham, Kent ME7 3LS UKTel: +44 (0)1634 260607 • Fax: +44 (0)1634 260278E-mail: [email protected] • Website: www.mecefireandsecurity.co.uk

    Certifi cate No. CFA-159 to LPS 1014

    Mercury EngineeringMercury House, Sandyford Industrial Estate, Foxrock, Dublin 18, IrelandTel: +353 1 216 3000 • Fax: +353 1 216 3006E-mail: [email protected] • Website: www.mercury.ie

    Certifi cate No. CFA-174 to LPS 1014

    MITIE Technical Facili ties Management LimitedLimeharbour Court, 5 Limeharbour, London E14 9RH UKTel: +44 (0)20 7001 7000 • Fax: +44 (0)20 7001 7272E-mail: [email protected] • Website: www.mitie.com

    Certifi cate No. CFA-129 to LPS 1014

    MITIE Technical Facili ties Management Limited (MITIE Fire and Security Systems)Ventura House, Ventura Park Road, Tamworth B78 3HL UKTel: +44 (0)1827 303251 • Fax: +44 (0)1827 309798Website: www.mitie.com

    Certifi cate No. CFA-163 to LPS 1014

    Niscayah LimitedRoding House, 970 Romford Road, London E12 5LP UKTel: +44 (0)20 8553 5932 • Fax: +44 (0)20 8478 8052E-mail: [email protected] • Website: www.niscayah.co.uk

    Certifi cate No. CFA 169 to LPS 1014

  • 8/16/2019 Redbook Vol1part1 2011

    16/389

    PART 1: SECTION 1LPS 1014 CERTIFIED FIRE DETECTION AND ALARM SYSTEM FIRMS

    10 24 Dec 2010

    PEL Services LimitedBelvue Business Centre, Belvue Road, Northolt, Middlesex UB5 5QQ UKTel: +44 (0)20 8839 2100 • Fax: +44 (0)20 8841 1948E-mail: [email protected] • Website: www.pel.co.uk

    Certifi cate No. CFA-179 to LPS 1014

    Protec Fire Detection plcProtec House, Churchill Way, Nelson, Lancashire BB9 6RT UKTel: +44 (0)1282 717171 • Fax: +44 (0)1282 717273E-mail: [email protected] • Website: www.protec.co.uk

    Including the following satellite offices:

    Unit 4, White Oak Square, London Road, Swanley, Kent BB8 1AG UKTel: +44 (0)845 456 5394 • Fax: +44 (0)845 456 5395

    Unit 10, Fulcram 4, Solent Way, Whiteley, Fareham, Hampshire PO15 7FT UKTel: +44 (0)845 456 5392 • Fax: +44 (0)845 456 5393

    5 Morston Court, Blakeney Way, Kingswood Lakeside, Cannock, Staffordshire WS11 8JB UKTel: +44 (0845 456 5398 • Fax: +44 (0845 456 5399

    Unit 1, Ashfield Court, Whitehall Road, Leeds LS12 5JB UKTel: +44 (0)845 456 53388 • Fax: +44 (0)845 456 53389

    Certifi cate No. CFA-132 to LPS 1014

    Raysil Security Systems LimitedUnit 16, Red Lion Business Centre, 218 Red Lion Road, Surbiton, Surrey KT6 7QD UKTel: +44 (0)20 8391 0202 • Fax: +44 (0)20 8391 4758E-mail: [email protected] • Website: www.raysil.co.uk

    Certifi cate No. CFA-127 to LPS 1014

    Scotshield LimitedCentury House, Chapelhall Industrial Estate, Airdrie, Scotland ML6 8QH UKTel: +44 (0)1236 767788 • Fax: +44 (0)1236 762233E-mail: [email protected]

    Including the following satellite office for service work onlyUnit 2, 9 Lotland Street, Inverness ML1 8QHTel: +44 (0)1463 709637 • Fax: +44 (0)1463 709638

    Certifi cate No. CFA-150 to LPS 1014

  • 8/16/2019 Redbook Vol1part1 2011

    17/389

    PART 1: SECTION 1LPS 1014 CERTIFIED FIRE DETECTION AND ALARM SYSTEM FIRMS

    24 Dec 2010 11

    Siemens plc, Building Technologies, Fire Safety DivisionBrunel House, Sir William Siemens Square, Frimley, Camberley, Surrey GU16 8QD UKTel: +44 (0)1276 696000 • Fax: +44 (0)1276 696133E-mail: [email protected] • Website: www.siemens.co.uk/buildingtechnologies

    Certifi cate No. CFA-100 to LPS 1014

    Static Systems Group PlcHeath Mill Road, Wombourne, Staffordshire WV5 8AN UKTel: +44 (0)1902 895551 • Fax: +44 (0)1902 324969E-mail: [email protected] • Website: www.staticsystems.co.uk

    Certifi cate No. CFA-135 to LPS 1014

    T V F (UK) Limited59-69 Queens Road, High Wycombe, Buckinghamshire HP13 6AH UKTel: +44 (0)1494 450641 • Fax: +44 (0)1494 465378E-mail: [email protected] • Website: www.tvfltd.co.uk

    Certifi cate No. CFA-128 to LPS 1014

    Thameside Fire Protection Co. Limi tedUnit 4, Sovereign Business Park, Cranes Farm Road, Basildon, Essex SS14 3JD UKTel: +44 (0)1268 597999 • Fax: +44 (0)1268 597998E-mail: [email protected] • Website: www.thamesidefire.co.uk

    Certifi cate No. CFA-171 to LPS 1014

    Trinity Protection Systems LimitedLittle Bridge Business Park, Oil Mill Lane, Clyst St.Mary, Exeter, Devon EX5 1AG UKTel: +44 (0)1392 874455 • Fax: +44 (0)1392 875546E-mail: [email protected] • Website: www.trinityprotection.co.uk

    Certifi cate No. CFA-160 to LPS 1014

    Trinity Protection Systems LimitedUnit B12a, Holly Farm Business Park, Honiley, Warwickshire CV8 INP UKTel: +44 (0)1926 485080 • Fax: +44 (0)1926 485090E-mail: [email protected] • Website: www.trinityprotection.co.uk

    Certifi cate No. CFA-167 to LPS 1014

  • 8/16/2019 Redbook Vol1part1 2011

    18/389

    PART 1: SECTION 1LPS 1014 CERTIFIED FIRE DETECTION AND ALARM SYSTEM FIRMS

    12 24 Dec 2010

    Trinity Protection Systems Limited121A Milton Park, Abingdon, Oxfordshire OX14 4SA UKTel: +44 (0)1235 862456 • Fax: +44 (0)1235 834450E-mail: [email protected] • Website: www.trinityprotection.co.uk

    Certifi cate No. CFA-168 to LPS 1014

    Tyco Fire and Integrated Solutions (the trading company for Tyco Fire and IntegratedSolutions (UK) Limited and Tyco Fire and Integrated Solut ions (Ireland) Limited)1610 Park Avenue, Aztec West, Almondsbury, Bristol BS32 4UA UKTel: +44 (0)1454 240071 • Fax: +44 (0)1454 626443Website: www.tycofis.com

    Certifi cate No. CFA-170 to LPS 1014

    Tyco Fire and Integrated Solutions (the trading company for Tyco Fire and IntegratedSolutions (UK) Limited and Tyco Fire and Integrated Solut ions (Ireland) Limited)Tyco House, 57-63 Farnham Road, Slough, Berkshire SL1 3TN UKTel: +44 (0)1753 574111 • Fax: +44 (0)1753 824226Website: www.tycofis.com

    Certifi cate No. CFA-157 to LPS 1014

    Tyco Fire and Integrated Solutions (the trading company for Tyco Fire and IntegratedSolutions (UK) Limited and Tyco Fire and Integrated Solut ions (Ireland) Limited)Hillcrest Business Park, Cinderbank, Dudley, West Midlands DY2 9AP UKTel: +44 (0)1384 458993 • Fax: +44 (0)1384 458981Website: www.tycofis.com

    Certifi cate No. CFA-103 to LPS 1014

    Vipond Fire Protection Limited10-12 Glenfield Road, Kelvin Industrial Estate, East Kilbride, Lanarkshire G75 0RA UKTel: +44 (0)1355 2375 25/80/88 • Fax: +44 (0)1355 263399E-mail: [email protected] • Website: www.vipondfire.co.uk

    Certifi cate No. CFA-173 to LPS 1014

  • 8/16/2019 Redbook Vol1part1 2011

    19/389

    PART 1: SECTION 2FIRE DETECTION AND ALARM SYSTEMS

    24 Dec 2010 13

     A fire detection and fire alarm system is typically made up of a number of inter-linked components includingdetectors, manual call points, and alarm sounders connected to control and indicating equipment by means ofone or more transmission paths. All system components, including the control and indicating equipment arealso connected to a power supply directly or indirectly.

     A fire detection and alarm system may be linked to other systems such as fire protection, or buildingmanagement systems. These other systems are not considered as part of the fire detection and alarmsystems.

    The fire detection and alarm systems may be networked together.

    Each of the components that constitute the fire detection and alarm system may be individually tested andapproved against their appropriate standard to demonstrate their own performance and reliability but in orderto ensure their compatibility and performance together within the system, certain system tests andrequirements must be fulfilled.

    The system standard specifies the requirements for compatibility and connectability assessment of system

    components that either comply with the requirements of EN 54 and/or with a manufacturer’s specification. Thestandard also includes requirements for the integrity of the fire detection and fire alarm system whenconnected to other systems.

    This section lists approved fire detection and alarm systems suitable for use in buildings for the protection ofpeople and property. The system requirements ensure the compatibility of the different components of thesystem work reliably together. Each component of the fire detection and alarm systems listed in this sectionare approved to the applicable product standard and are listed in Sections 3, 4.1, 5, 6, and 7. The approvalprocess for the system is outlined in scheme document SD040.

    Systems listed in this section have been approved to LPS 1054: 2001 Requirements for the evaluation ofcomponent compatibility for fire alarm systems

    This standard was designed for the UK market and applies to systems incorporating control and indicatingequipment and power supply equipment complying with EN 54-2 Fire detection and fire alarm systems -Control and indicating equipment and EN 54-4 Fire detection and fire alarm systems - Power supplyequipment respectively.

    Networked systems are evaluated by ensuring that each control panel connected to the network can operateas a stand alone unit, in the event of failure of the network connections, and that failure of a control panel willnot affect other control panels on the network.LPCB is now accepting products for approval to EN 54-13: 2005 Compatibility assessment for systemcomponents which is applicable to the EU market.

    Note: Since LPCB uses national and international standards for the listing of products, in some instances, therequirements of these standards may conflict with the recommendations of local codes of practice. We

    recommend that specifiers seek advice from the relevant local authorities and amend their specificationsaccordingly.

    Control Equipment LimitedHillcrest Business Park, Dudley, West Midlands DY2 9AP UKTel: +44 (0)1384 458651 • Fax: +44 (0)1384 458972E-mail: [email protected] • Website: www.controlequipment.com

    Certificate No: 018b to LPS 1054-1Certificate No: 018d to LPS 1054-1

  • 8/16/2019 Redbook Vol1part1 2011

    20/389

    PART 1: SECTION 2FIRE DETECTION AND ALARM SYSTEMS

    14 24 Dec 2010

    Certificated Products LPCB Ref.No.

    Precept fire alarm system Comprising the following products:

    Control Equipment LimitedPrecept 2, 4, 8, 16 and 32 zone control and indicating equipment.

     Apollo Fire Detectors Limited55000-100 grade 1 rate of rise heat detector (45681-200 base)55000-200 ionization smoke detector (45681-200 base)55000-300 photoelectic smoke detector (45681-200 base)53531-221 grade 1 rate of rise heat detector (45681-007 base) continued53541-151 ionization smoke detector (45681-007 base)53541-200 photoelectric smoke detector (45681-007 base)55000-101 grade 2 rate of rise heat detector (45681-200 base)55000-102 grade 3 rate of rise heat detector (45681-200 base)55000-103 range 1 rate of rise heat detector (45681-200 base)55000-104 range 2 rate of rise heat detector (45681-200 base)55000-210 integrating ionization smoke detector (45681-200 base)

    Hochiki CorporationDFE-60 grade 2 fixed temperature heat detector (YBF-RL/4H5 base)DFE-90 range 1 fixed temperature heat detector (YBF-RL/4H5 base)DCC-1EL grade 1 rate of rise heat detector (YBF-RL/4H5 base)DCC-2EL grade 2 rate of rise heat detector (YBF-RL/4H5 base)

    DCC-R1EL range 1 rate of rise heat detector (YBF-RL/4H5 base)Hochiki Europe

    SLK-E photoelectric smoke detector (YBF-RL/4H5 base)SIH-E ionization smoke detector (YBF-RL/4H5 base)

    KAC Alarm Company LimitedKR72 manual call point.

    Photain Controls LimitedISD-P91 ionization smoke detector PRR-P91 grade 1 rate of rise heat detector PHD-P90 range 1 fixed temperature heat detector 

    Signature Industries - Clifford and Snell Alarms.MCP/R/F manual call pointMCP/R/S manual call point

    System Sensor, St. Charles, Illinois, USA.1151E ionization smoke detector (B401 base)2151E photoelectric smoke detector (B401 base)

    018b/S1

    Discovery fire alarmsystem

    Comprising the following products:

     Control Equipment LimitedDiscovery analogue addressable control and indicating equipment

     Apollo Fire Detectors Limited55000-400 grade 2 analogue temperature monitor 55000-420 grade 2 analogue temperature monitor 58000-400 Discovery temperature monitor 55000-600 analogue photoelectric smoke monitor 55000-620 analogue photoelectric smoke monitor 58000-600 Discovery optical smoke monitor 55000-500 analogue ionisation smoke monitor 55000-520 analogue ionisation smoke monitor 58000-500 Discovery ionisation smoke monitor 58000-700 Discovery multisensor monitor 55000-900 surface and flush mounted manual call point

    55000-910 flush mounted manual call point55000-950 waterproof addressable manual call point58000-900 flush and surface mounted manual call point58000-910 flush mounted manual call point58000-920 surface mounted manual call point55000-700 XP95 short circuit isolator 45681-321 XP95 negative isolating base45681-210 XP95 addressable mounting base

    018d/01

  • 8/16/2019 Redbook Vol1part1 2011

    21/389

    PART 1: SECTION 2FIRE DETECTION AND ALARM SYSTEMS

    24 Dec 2010 15

    Notifier Fire Systems by HoneywellCharles Avenue, Burgess Hill, West Sussex RH15 9UF UKTel: +44 (0)1444 230300 • Fax: +44 (0)1444 230888E-mail: [email protected] • Website: www.notifierfiresystems.co.uk

    Certificate No: 154e to LPS 1054: Issue 2.1

    Certificated Products LPCB Ref.No.

    Notifier NFS2-8 Fire AlarmSystem

    Comprising the following products:

    Notifier Fire Systems Ltd 124-345-002 NFS2-8, 2 Zone Conventional Control and Indicating Equipment 124-345-004 NFS2-8, 4 Zone Conventional Control and Indicating Equipment 124-345-008 NFS2-8, 8 Zone Conventional Control and Indicating Equipment

    Morley-IAS Fire Systems ECO 1002 Photoelectric smoke and heat detector  ECO 1003 Photoelectric smoke detector  ECO 1004T High Temperature 78C heat detector class BS ECO 1005 Heat detector class A1R ECO 1005T Fixed temperature heat detector class A2S

    KAC Alarm Company Ltd MCP1A-Rxxxxx Indoor/outdoor surface/flush mountingconventional manual call point NS4/R Sounder 4 tone wall mounting conventional (red) NS4/W Sounder 4 tone wall mounting conventional (white) NS14/R Sounder 14 tones wall mounting conventional (red)NS14/W Sounder 14 tones wall mounting conventional (white)

    154e/S1

    UTC Fire & Security (Africa) trading as ZitonZiton House, 555 Voortrekker Road, Maitland 7405, Cape Town, Republic of South AfricaTel: +27 21 5066000 • Fax: +27 21 5066100Website: www.utcfireandsecurity.com

    UK Sales enqu iries:Ziton LimitedTel: +44 (0)1908 281981 • Fax: +44 (0)1908 282554

    Certificate No: 092f to LPS 1054

    Certificated Products LPCB Ref.No.

    ZP5 Mark 5 analogueaddressable fire alarmsystem

    Comprising the following products: ZP5 Mark 5 control and indicating equipment 092e/01 ZP710-2 analogue ionisation smoke detector (ZP7-SB1 base) 092n/01 ZP730-2 analogue optical smoke sensor (ZP7-SB1 base) 092n/02 ZP720-3 grade 1 analogue heat sensor (ZP7-SB1 base) 092p/01 ZP785-2 addressable flush and surface mounted call point 092d/01

    092f/S1

    ZP3 analogue addressablefire alarm system

    Comprising of the following products: ZP3 analogue addressable control and indicating equipment 092h/01 ZP710-2 analogue addressable ionisation smoke detector 092n/01 ZP730-2 analogue addressable optical smoke detector 092n/02 ZP720-3 analogue addressable grade 1 heat detector 092p/01 ZP785-2 addressable flush and surface mounted manual call point 092d/01 ZP760-2 short circuit isolator 092j/01

    092f/S2

  • 8/16/2019 Redbook Vol1part1 2011

    22/389

    PART 1: SECTION 3CONTROL AND INDICATING EQUIPMENT

    16 24 Dec 2010

    Control and Indicating Equipment (CIE) is a component of a fire detection and alarm system through whichother components may be connected to it such as detectors, manual call points, sounders, routing equipment,voice alarm equipment and fire protection equipment. It is supplied with power from power supply equipmentwhich may be housed within the CIE enclosure or a separate enclosure.

    CIE is used to receive and send out signals that are related to fire. CIE also monitors the system for faults(short and open circuit or power supply faults) and indicates the status of the fire detection and alarm system.

    CIE is designed to meet a European standard such as EN 54-2 or international standard such as ISO 7240-2has certain options with requirements. For example, it may be designed to provide a signal to fire protectionequipment or have dependencies on more than one alarm signal. Some CIEs have other functions which arenot specified in the standard. These additional features are normally assessed such that they do not

     jeopardise compliance.The choice of CIE is dependant on the specific applications as recommended in the application guidelines fora specific job or building.

    Some CIEs have associated repeaters or mimic panels. These are normally used to repeat the indications

    given on the main CIE and sometimes they have control functions such as silencing sounders. There are nopublished standards that these repeaters or mimics can be tested against.

    This section lists Control and Indicating Equipment, and power supply equipment approved for use in firedetection and fire alarm systems in buildings. Repeaters or mimics that are listed in this section are onlyapproved with their associated CIE and are subjected to the same environmental tests as the CIE. The initialapproval and continued approval processes of this type of equipment is outlined in scheme document SD040.

    Products listed in this section have been approved to:

    EN 54-2: 1997 Control and Indicating Equipment;

    EN 54-2: 1997 + A1: 2006 Control and Indicating Equipment;

    EN 54-4: 1997 Power supply equipment;

    EN 54-4: 1997 + A1: 2002 and A2: 2006 Power supply equipment;

    SO 7240-2: 2003 Control and Indicating Equipment;

      ISO 7240-4: 2003 Power supply equipment;

     Audi t:Regular product auditing and regular factory inspections are carried out by LPCB ensuring high manufacturingstandards and continued compliance with the applicable product standard.

    Notes:1. EN 54-2: 1997 is a harmonised standard for the Construction Products Directive and CE marking isrequired for most of the European market from 1 August 2009. It is therefore recommended that control andIndicating Equipment are certificated to EN 54-2: 1997 + A1: 2002

    2. EN 54-4: 1997 is a harmonised standard for the Construction Products Directive and CE marking isrequired for most of the European market from 1 August 2009. It is therefore recommended that power supplyequipment are certificated to EN 54-4: 1997 + A1: 2002 and A2: 2006.

    3. Since the LPCB uses national and international standards for the listing of products, in some instances therequirements of these standards may conflict with the recommendations of local codes of practice. Werecommend that specifiers seek advice from the relevant local authorities and amend their specificationsaccordingly.

    4. Where the Control and Indicating Equipment is of modular construction, and the use of certain modules (orprinted circuit boards PCBs) is optional, these are listed with the applicable equipment.

  • 8/16/2019 Redbook Vol1part1 2011

    23/389

    PART 1: SECTION 3CONTROL AND INDICATING EQUIPMENT

    24 Dec 2010 17

     Advanced Electronics Limi ted34 Moorland Way, Nelson Park, Cramlington, Northumberland NE23 1WE UKTel: +44 (0) 1226 737 465 • Fax: +44 (0) 1226 737 469E-mail: [email protected] • Website: www.Advel.co.uk

    Certificate No: 018c to EN 54:Part 2 and 4: 1997

    Certificated Products LPCB Ref.No.

    Mx-1002 2 zone conventional control and indicating equipmentIncorporating as modular units:

     C1627 Mother board C1628 Display board C1631 Repeater interface board (option)

    018c/02

    Certified with the following options from EN 54 Part 2:7.8 Output to fire alarm devices7.9 Output to fire routing equipment7.10 Output to automatic fire protection equipment7.11 Delays to outputs8.9 Output to fault warning equipment10 Test condition

    Mx-1004 4 zone conventional control and indicating equipmentIncorporating as modular units:

     C1627 Mother board C1628 Display board C1631 Repeater interface board (option)

    018c/03

    Certified with the following options from EN 54 Part 2:7.8 Output to fire alarm devices7.9 Output to fire routing equipment7.10 Output to automatic fire protection equipment7.11 Delays to outputs8.9 Output to fault warning equipment10 Test condition

    Mx-1008 8 zone conventional control and indicating equipment

    Incorporating as modular units: C1627 Mother board C1628 Display board C1631 Repeater interface board (option)

    018c/04

    Certified with the following options from EN 54 Part 2:7.8 Output to fire alarm devices7.9 Output to fire routing equipment7.10 Output to automatic fire protection equipment7.11 Delays to outputs8.9 Output to fault warning equipment10 Test condition

    Mx-1016 16 zone conventional control and indicating equipmentIncorporating as modular units:

     C1627 Mother board C1628 Display board C1631 Repeater interface board (option)

    018c/05

    Certified with the following options from EN 54 Part 2:7.8 Output to fire alarm devices7.9 Output to fire routing equipment7.10 Output to automatic fire protection equipment7.11 Delays to outputs8.9 Output to fault warning equipment10 Test condition

    Mx-1032 32 zone conventional control and indicating equipmentIncorporating as modular units:

     C1627 Mother board C1629 Display board C1632 16 Zone Expansion board C1652 5A Power supply board C1631 Repeater interface board (option)

    018c/06

    Certified with the following options from EN 54 Part 2:7.8 Output to fire alarm devices

    7.9 Output to fire routing equipment7.10 Output to automatic fire protection equipment7.11 Delays to outputs

  • 8/16/2019 Redbook Vol1part1 2011

    24/389

    PART 1: SECTION 3CONTROL AND INDICATING EQUIPMENT

    18 24 Dec 2010

    Certificated Products LPCB Ref.No.

    8.9 Output to fault warning equipment10 Test condition

    Mx-1108 8 zone conventional repeater unitIncorporating as modular units:

     C1627 Mother board C1628 Display board C1631 Repeater interface board

    018c/R01

    Mx-1116 16 zone conventional repeater unitIncorporating as modular units:

     C1627 Mother board C1628 Display board C1631 Repeater interface board

    018c/R02

    Mx-1132 32 zone conventional repeater unitIncorporating as modular units:

     C1627 Mother board C1629 Display board C1631 Repeater interface board

    018c/R03

     AMPAC Europe Limi tedUnit 18 Networkcentre, Yorkshire Way, Westmoor Park, Doncaster DN3 3GW UKTel: +44 (0)1302 833522 • Fax: +44 (0)1302 835021E-mail: [email protected] • Website: www.ampac.net

    Certifi cate No: 952a to EN54-2: 1997 + A1: 2006 and EN54-4: 1997 + A1: 2002 + A2: 2006

    Certificated Products LPCB Ref.No.

    LoopSense 8281-0105 One loop, 32 Zone analogue addressable control and indicating equipment.

    Incorporating the following units:

     BRD82MBA Main Termination Board BRD82ZICC Zone Interface & Control Card PSU2397 Power Supply Unit ASS82ZICC Zone Indicator & LCD Assembly (8210)

     Certificated with the following options with requirements from EN54-2:

    7.8 Output to fire alarm devices7.9.1 Output to fire alarm routing equipment7.9.2 Alarm confirmation input from fire alarm routing equipment7.11 Delay to outputs7.12.1 Dependencies on more than one alarm signal Type A7.12.2 Dependencies on more than one alarm signal Type B7.12.3 Dependencies on more than one alarm signal Type C8.3 Fault signal from points8.9 Output to fault warning routing equipment

    9.5 Disablement of each addressable point10 Test condition

    966a/01

    Note:

    1. This product approval does not constitute compliance with the fire detectionand alarm systems requirements of EN 54-13.

    LoopSense 8281-0205 Two loop, 32 Zone analogue addressable control and indicating equipment.

    Incorporating the following units:

    BRD82MBA Main Termination BoardBRD82ZICC Zone Interface & Control CardPSU2397 Power Supply Unit8210-0001 2nd loop activation KeyBRD82LSD Loop Activation Board ASS82ZICC Zone Indicator & LCD Assembly (8210)

    Certificated with the following options with requirements from EN54-2:

    966a/02

  • 8/16/2019 Redbook Vol1part1 2011

    25/389

    PART 1: SECTION 3CONTROL AND INDICATING EQUIPMENT

    24 Dec 2010 19

    Certificated Products LPCB Ref.No.

    7.8 Output to fire alarm devices7.9.1 Output to fire alarm routing equipment7.9.2 Alarm confirmation input from fire alarm routing equipment7.11 Delay to outputs7.12.1 Dependencies on more than one alarm signal Type A7.12.2 Dependencies on more than one alarm signal Type B7.12.3 Dependencies on more than one alarm signal Type C8.3 Fault signal from points8.9 Output to fault warning routing equipment9.5 Disablement of each addressable point10 Test conditionNote:

    1. This product approval does not constitute compliance with the fire detectionand alarm systems requirements of EN 54-13.

     AMPAC Technologies PTY Ltd7 Ledgar Road, Balcatta 6021, AustraliaTel: +618 (9242) 3333 • Fax: +618 (9242) 3334E-mail: [email protected] • Website: www.ampac.net

    Certifi cate No: 966a to EN54-2: + A1 and EN54-4: A1+ A2

    Certificated Products LPCB Ref.No.

    LoopSense 8281-0105 One loop, 32 Zone analogue addressable control and indicating equipment.

    Incorporating the following units:

     BRD82MBA Main Termination Board BRD82ZICC Zone Interface & Control Card PSU2397 Power Supply Unit ASS82ZICC Zone Indicator & LCD Assembly (8210)

     Certificated with the following options with requirements from EN54-2:

    7.8 Output to fire alarm devices7.9.1 Output to fire alarm routing equipment7.9.2 Alarm confirmation input from fire alarm routing equipment7.11 Delay to outputs7.12.1 Dependencies on more than one alarm signal Type A7.12.2 Dependencies on more than one alarm signal Type B7.12.3 Dependencies on more than one alarm signal Type C8.3 Fault signal from points8.9 Output to fault warning routing equipment

    9.5 Disablement of each addressable point10 Test condition

    966a/01

    Note:

    1. This product approval does not constitute compliance with the fire detectionand alarm systems requirements of EN 54-13.

    LoopSense 8281-0205 Two loop, 32 Zone analogue addressable control and indicating equipment.

    Incorporating the following units:

    BRD82MBA Main Termination BoardBRD82ZICC Zone Interface & Control CardPSU2397 Power Supply Unit8210-0001 2nd loop activation KeyBRD82LSD Loop Activation Board ASS82ZICC Zone Indicator & LCD Assembly (8210)

     Certificated with the following options with requirements from EN54-2:

    966a/02

  • 8/16/2019 Redbook Vol1part1 2011

    26/389

    PART 1: SECTION 3CONTROL AND INDICATING EQUIPMENT

    20 24 Dec 2010

    Certificated Products LPCB Ref.No.

    7.8 Output to fire alarm devices7.9.1 Output to fire alarm routing equipment7.9.2 Alarm confirmation input from fire alarm routing equipment7.11 Delay to outputs7.12.1 Dependencies on more than one alarm signal Type A7.12.2 Dependencies on more than one alarm signal Type B7.12.3 Dependencies on more than one alarm signal Type C8.3 Fault signal from points8.9 Output to fault warning routing equipment9.5 Disablement of each addressable point10 Test conditionNote:

    1. This product approval does not constitute compliance with the fire detectionand alarm systems requirements of EN 54-13.

    Bardic by Honeywell140 Waterside Road, Hamilton Industrial Estate, Leicester LE5 1TN UKTel: +44 (0) 116 246 2212 • Fax: +44 (0) 116 246 2210Website: www.bardic.co.uk

    Certifi cate No: 154d to EN 54-2: 1997, EN 54-4: 1997

    Certificated Products LPCB Ref.No.

    Bardic Zircon 2 Zone conventional controls and indicating equipment

    Including the following versions:002-509-229 Language region 2, black & grey

    154d/09

    Bardic Zircon 4 Zone conventional controls and indicating equipment

    Including the following versions:002-509-249 Language region 2, black & grey

    154d/10

    Bardic Zircon 8 Zone conventional controls and indicating equipment

    Including the following versions:002-509-289 Language region 2, black & grey

    154d/11

    Certified with the following options with requirements from EN 54 Part 2:7.8 Output to fire alarm devices7.9 Output to fire routing equipment7.11 Delays to outputs7.12 Coincidence detection10 Test condition

    Certifi cate No: 154g-(cl-3) to EN 54-2: 1997 + A1: 2006, EN 54-4: 1997 + A1: 2002 + A2: 2006

    Certificated Products LPCB Ref.No.

    Zircon 2 Zone 002-509-229 Bardic Zircon, 2 zone, region 2, black grey 154g/06Zircon 4 Zone 002-509-249 Bardic Zircon, 4 zone, region 2, black grey 154g/07Zircon 8 Zone 002-509-289 Bardic Zircon, 8 zone, region 2, black grey 154g/08

    Incorporating the following units:020-747 8-way relay kit020-772 4-way monitored sounder kit

    Certified with the following options with requirements from EN 54 Part 2:

    7.8 Output to fire alarm devices7.9.1 Output to fire alarm routing equipment7.9.2 Alarm confirmation input from fire alarm routing equipment

  • 8/16/2019 Redbook Vol1part1 2011

    27/389

    PART 1: SECTION 3CONTROL AND INDICATING EQUIPMENT

    24 Dec 2010 21

    7.10.1 Output to automatic fire protection equipment: Type A7.10.3 Output to automatic fire protection equipment: Type C7.10.4 Fault monitoring of f ire protection equipment7.11.1 Delays to outputs7.11.2 Manual or automatic switching of delays to outputs7.12.2 Dependency on more than one alarm signal: Type B8.9 Output to fault warning routing equipment10 Test condition

    CarillionHamilton Industrial Park, 140 Waterside Road, Leicester LE5 1TN UKTel: 0116 246 2000 • Fax: 0116 246 2300Website: www.gent.co.uk

    Certifi cate No: 042bc to EN 54-2: 1997+A1:2006 and EN 54-4: 1997 + A1:2002 + A2:2006

    Certificated Products LPCB Ref.No.

    CP2-AMC Two loop analogue addressable control and indicating equipment(English language)

    Incorporating as modular units:

     2434-859 Master Controller Board (MCB) 2434-862 Power Supply Unit 2434-762 Display and Key card (DKC) 2434-669 Loop processor card 4374-161 Text Membrane (English) 2434-861 Copper network card

    Scope of approval does not include the operation of the network card)

    Certified with the following options with requirements from EN 54-2:

    7.8 Output to fire alarm devices 7.11 Delays to outputs 8.3 Fault signals from points 9.5 Disablement of each address point 10 Test condition

    042bc/04

    CP4-AMC One to Four loop analogue addressable control and indicating equipment (Englishlanguage)

    Incorporating as modular units:

     2434-863 Master controller card (M.C.C) 2434-710 Loop card 2434-831 Power supply PCB 2434-854 Backplane PCB 2434-861 Display and Key card (D.K.C)

     2434-864 Terminal card 2434-565 Printer Module 4374-157 Text Membrane (English) 2434-674 Copper network card

     Note: Scope of approval does not  include the operation of the network card)

     Certified with the following options with requirements from EN 54-2:

    7.8 Output to fire alarm devices 7.11 Delays to outputs 8.3 Fault signals from points 9.5 Disablement of each address point 10 Test condition

    042bc/07

    CP4-72-AMC One to Six loop analogue addressable control and indicating equipment (EnglishLanguage)

    Incorporating as modular units:

     2434-863 Master controller card (M.C.C)

    042bc/11

  • 8/16/2019 Redbook Vol1part1 2011

    28/389

    PART 1: SECTION 3CONTROL AND INDICATING EQUIPMENT

    22 24 Dec 2010

    Certificated Products LPCB Ref.No.

     2434-710 Loop card 2434-992 Thermistor board 2434-860 Battery terminal board 2434-832 Power supply PCB 2434-854 Backplane PCB 2434-761 Display and Key card (D.K.C) 2434-864 Terminal card 2434-565 Printer module 4374-157 Text Membrane (English) 2434-674 Copper network card

    ( Note: Scope of approval does not  include the operation of the network card)

     Certified with the following options with requirements from EN 54-2:

    7.8 Output to fire alarm devices 7.11 Delays to outputs 8.3 Fault signals from points 9.5 Disablement of each address point 10 Test condition

    CEAGPostfach 11 16, D-59491 Soest, GermanyTel: +44 (0)1302 303397 • Fax: +44 (0)1302 303220Website: www.ceag.de

    Certifi cate No: 714a to EN 54-2: 1997 and EN 54-4: 1997

    Certificated Products LPCB Ref.No.

    CF 3000 Analogue addressable 2 and 4 Loop control and indicating equipmentIncorporating the following units:

     ADF6 Back Assembled back box YPCB2153 Motherboard PCB YPCB2147 PSU PCB YPCB2148 2 Loop Card (2 off) ADF6Screen Touch Screen YPCB2185 Complete Display + Micro PCB ADF6 DISPCOVER Display PCB Cover  ADF6FACIA Front Moulding ADF6PRINTDOOR Printer Door Moulding BAT-NP12-12 Batteries (2 off) ADF6HINGE Door Hinges ADF6OPFACIA Optional Anti Tamper Cover  ADF6PRINTER Printer  YPCB2187 Fire Brigade Interface

    714a/01

    Certified with the following options with requirements from EN54-2:1997: 7.8 Output to fire alarm device(s)

     7.9 Output to fire alarm routing equipment 7.10 Output to automatic fire protection equipment 7.11 Delays to the actioning of outputs fire alarm devices and fire routing

     equipment 7.12 Coincidence detection 7.13 Alarm counter   8.9 Output to fault warning routing equipment 9.5 Disablement of each address point 10 Test condition

  • 8/16/2019 Redbook Vol1part1 2011

    29/389

    PART 1: SECTION 3CONTROL AND INDICATING EQUIPMENT

    24 Dec 2010 23

    Chubb Sécurité10 Avenue du Centaure, B.P.38408-95806, Cergy-Pontoise Cedex, FranceTel: +33 1 30173737 • Fax: +33 1 30173707Website: www.chubbsecurite.com

    Certifi cate No: 747a to EN 54-2: 1997 and EN 54-4: 1997

    Certificated Products LPCB Ref.No.

    Control Master 1000M-M 4 loop analogue addressable control indicating equipment (Medium enclosure) 747a/01Control Master 1000M-S 4 loop analogue addressable control indicating equipment (Small enclosure)

    Incorporating the following units: CE00504 Main CPU CE00505 Main board display CE00506 Connection board CE00490 100W PSU

    and as optional modular units: CE00508 16 Zone LED module CE00507 32 Zone LED module CE00513 4 alarm zone control and indicating module CE00447 2 Way network interfaceCE00446 4 Way network interface CE00435A Lon high integrity isolatorCE00514 16 fire protection zone control and indicating module CE00503 2 Loop System sensor interface CE00520 2 Loop Apollo interface

    747a/01

    Certified with the following options with requirements from EN 54-2:7.8 Output to fire alarm devices7.11 Delays to outputs8.3 Fault signals from points9.5 Disablement of addressable points10 Test condition

    Control Master 1020 M 2 loop analogue addressable control indicating equipment (Medium enclosure) 747a/02

    Control Master 1020 S 2 loop analogue addressable control indicating equipment (Small enclosure)Incorporating the following units:

     CE00504 Main CPU CE00505 Main board display CE00506 Connection board CE00490 100W PSU

    and as optional modular units: CE00508 16 Zone LED module CE00507 32 Zone LED module CE00447 2 Way network interface CE00446 4 Way network interface CE00435A Lon high integrity isolator  CE00513 4 alarm zone control and indicating module CE00514 16 fire protection zone control and indicating module

    747a/02

    Certified with the following options with requirements from EN 54-2:

    7.8 Output to fire alarm devices7.11 Delays to outputs8.3 Fault signals from points9.5 Disablement of addressable points10 Test condition

    Control Master 1010S 1 loop, analogue addressable control indicating equipmentIncorporating the following units:

     CE00510 Main CPU CE00505 Main board display CE00506 Connection board CE00490 100W PSU

    and as optional modular units: CE00508 16 Zone LED module CE00436A 4 Way sounder board CE00437A 8 Way sounder board

     CE00507 32 Zone LED module CE00435A Lon high integrity isolator  CE00513 4 alarm zone control and indicating module

    747a/03

  • 8/16/2019 Redbook Vol1part1 2011

    30/389

    PART 1: SECTION 3CONTROL AND INDICATING EQUIPMENT

    24 24 Dec 2010

    Certificated Products LPCB Ref.No.

     CE00514 16 fire protection zone control and indicating moduleCertified with the following options with requirements from EN 54-2:7.8 Output to fire alarm devices7.11 Delays to outputs8.3 Fault signals from points9.5 Disablement of addressable points10 Test condition

    Control master 1000R-S Remote unitIncorporating the following units:

     CE00509 Display board CE00484B Main board CE00489 40 W PSU

    and as optional modular units:CE00508 16 Zone LED module CE00507 32 Zone LED moduleCE00447 2 way network interface CE00446 4 way network interfaceCE00435A Lon high integrity isolator  CE00513 4 alarm zone control and indicating module CE00514 16 Fire protection zone control and indicating module

    747a/R01

    Control master 1000R-M Remote unitIncorporating the following units:

     CE00509 Display board CE00484B Main board CE00490 100 W PSU

     and as optional modular units: CE00508 16 Zone LED module CE00507 32 Zone LED module CE00513 4 alarm zone control and indicating module CE00447 2 Way network interfaceCE00446 4 Way network interface CE00435A Lon high integrity isolatorCE00514 16 fire protection zone control and indicating module

    747a/R02

    The following repeaters and the remote units are approved for use with the Control Master 1000 range of control and indicatingequipment (incorporating 1020 and 1010):

    RS Repeater 747a/R03RS Repeater with LCD display 747a/R04Lon Repeater with LCD display 747a/R05Remote unit 747a/E01

    Incorporating the following units:CE00503 2 Loop System sensor interfaceCE00489 40W PSU

    and as optional modular units:CE00490 100W PSUCE00435A Lon high integrity isolator 

    Computionics Limited (Trading as C-Tec)Stephens Way, Goose Green, Wigan, Lancashire WN3 6PH UKTel: +44 (0)1942 322744/42444 • Fax: +44 (0)1942 829867E-mail: [email protected] • Website: www.c-tec.co.uk

    Certificate No: 176a to EN 54: Part 2 and 4: 1997

    Certificated Products LPCB Ref.No.

    CFP 2 Conventional 2 zone control and indicating equipment 176a/01CFP 4 Conventional 4 zone control and indicating equipment 176a/02

    CFP 8 Conventional 8 zone control and indicating equipment 176a/03

  • 8/16/2019 Redbook Vol1part1 2011

    31/389

  • 8/16/2019 Redbook Vol1part1 2011

    32/389

    PART 1: SECTION 3CONTROL AND INDICATING EQUIPMENT

    26 24 Dec 2010

    Certificated Products LPCB Ref.No.

    Incorporating the following units: SPF0706000 Switch mode power supply board SPF0501201 XFP Apollo 2 loop, main motherboard SPF0501200 Display board "Keypad display"

    Certified with the following options with requirements from EN54-2: 19977.8 Output to fire alarm device(s)7.11 Delays to the actioning of outputs fire alarm devices and fire routing

     equipment7.12.1 Dependencies on more than one alarm signal - Type A7.12.2 Dependencies on more than one alarm signal - Type B7.12.3 Dependencies on more than one alarm signal - Type C7.13 Alarm counter  8.3 Fault signals from points9.5 Disablement of each address point10 Test conditionNotes:1) Scope of approval does not include the operation of the network functionality

    XFP502K/X 2 Loop, 32 zone analogue addressable control and indicating equipment using ApolloProtocol, metal housing + KeyswitchIncorporating the following units:

     SPF0706000 Switch mode power supply board SPF0501201 XFP Apollo 2 loop, main motherboard SPF0501199 Display board "Keyswitch display"

    Certified with the following options with requirements from EN54-2: 19977.8 Output to fire alarm device(s)7.11 Delays to the actioning of outputs fire alarm devices and fire routing

     equipment7.12.1 Dependencies on more than one alarm signal - Type A7.12.2 Dependencies on more than one alarm signal - Type B7.12.3 Dependencies on more than one alarm signal - Type C7.13 Alarm counter  8.3 Fault signals from points9.5 Disablement of each address point10 Test condition

    176b/02

    Notes:

    1) Scope of approval does not include the operation of the network functionality.XFP502K/X/CON 2 Loop, 32 zone analogue addressable control and indicating equipment using Apollo

    Protocol + Keyswitch, metal housingIncorporating the following units:

     SPF0706000 Switch mode power supply board SPF0501201 XFP Apollo 2 loop, main motherboard SPF0501199 Display board "Keyswitch display"

    Certified with the following options with requirements from EN54-2: 19977.8 Output to fire alarm device(s)7.11 Delays to the actioning of outputs fire alarm devices and fire routing

     equipment7.12.1 Dependencies on more than one alarm signal - Type A7.12.2 Dependencies on more than one alarm signal - Type B7.12.3 Dependencies on more than one alarm signal - Type C7.13 Alarm counter  

    8.3 Fault signals from points9.5 Disablement of each address point10 Test condition

    176b/02

    Notes:1) Scope of approval does not include the operation of the network functionality

    XFP501/H 1 Loop, 32 zone analogue addressable control and indicating equipment using HochikiProtocol, metal housingIncorporating the following units:

     SPF0706000 Switch mode power supply board SPF0501212 XFP Hochiki 1 loop, main motherboard SPF0501200 Display board "Keypad display"

    Certified with the following options with requirements from EN54-2: 19977.8 Output to fire alarm device(s)7.11 Delays to the actioning of outputs fire alarm devices and fire routing

     equipment

    7.12.1 Dependencies on more than one alarm signal - Type A7.12.2 Dependencies on more than one alarm signal - Type B7.12.3 Dependencies on more than one alarm signal - Type C

    176b/03

  • 8/16/2019 Redbook Vol1part1 2011

    33/389

    PART 1: SECTION 3CONTROL AND INDICATING EQUIPMENT

    24 Dec 2010 27

    Certificated Products LPCB Ref.No.

    7.13 Alarm counter  8.3 Fault signals from points9.5 Disablement of each address point10 Test conditionNotes:1) Scope of approval does not include the operation of the network functionality.

    XFP501K/H 1 Loop, 32 zone analogue addressable control and indicating equipment using HochikiProtocol, metal housing + KeyswitchIncorporating the following units:

     SPF0706000 Switch mode power supply board SPF0501212 XFP Hochiki 1 loop metal case, main motherboard SPF0501199 Display board "Keyswitch display"

    Certified with the following options with requirements from EN54-2: 19977.8 Output to fire alarm device(s)7.11 Delays to the actioning of outputs fire alarm devices and fire routing

     equipment7.12.1 Dependencies on more than one alarm signal - Type A7.12.2 Dependencies on more than one alarm signal - Type B7.12.3 Dependencies on more than one alarm signal - Type C7.13 Alarm counter  

    8.3 Fault signals from points9.5 Disablement of each address point10 Test condition

    176b/03

    Notes:1) Scope of approval does not include the operation of the network functionality.

    XFP501/X 1 Loop, 32 zone analogue addressable control and indicating equipment using ApolloProtocol, metal housingIncorporating the following units:

     SPF0706000 Switch mode power supply board SPF0501211 XFP Apollo 1 loop, main motherboard SPF0501200 Display board "keypad display"

    Certified with the following options with requirements from EN54-2: 19977.8 Output to fire alarm device(s)7.11 Delays to the actioning of outputs fire alarm devices and fire routing

     equipment

    7.12.1 Dependencies on more than one alarm signal - Type A7.12.2 Dependencies on more than one alarm signal - Type B7.12.3 Dependencies on more than one alarm signal - Type C7.13 Alarm counter  8.3 Fault signals from points9.5 Disablement of each address point10 Test condition

    176b/04

    Notes:1) Scope of approval does not include the operation of the network functionality.

    XFP501/X/CON 1 Loop, 32 zone analogue addressable control and indicating equipment using ApolloProtocol, metal housingIncorporating the following units:

     SPF0706000 Switch mode power supply board SPF0501211 XFP Apollo 1 loop, main motherboard SPF0501200 Display board "keypad display"

    Certified with the following options with requirements from EN54-2: 19977.8 Output to fire alarm device(s)7.11 Delays to the actioning of outputs fire alarm devices and fire routing

     equipment7.12.1 Dependencies on more than one alarm signal - Type A7.12.2 Dependencies on more than one alarm signal - Type B7.12.3 Dependencies on more than one alarm signal - Type C7.13 Alarm counter  8.3 Fault signals from points9.5 Disablement of each address point10 Test condition

    176b/04

    Notes:1) Scope of approval does not include the operation of the network functionality

    XFP501K/X 1 Loop, 32 zone analogue addressable control and indicating equipment using ApolloProtocol, metal housing + Keyswitch Incorporating the following units:

     SPF0706000 Switch mode power supply board SPF0501211 XFP Apollo 1 loop, main motherboard SPF0501199 Display board "Keyswitch display"

    176b/04

  • 8/16/2019 Redbook Vol1part1 2011

    34/389

    PART 1: SECTION 3CONTROL AND INDICATING EQUIPMENT

    28 24 Dec 2010

    Certificated Products LPCB Ref.No.

    Certified with the following options with requirements from EN54-2: 19977.8 Output to fire alarm device(s)7.11 Delays to the actioning of outputs fire alarm devices and fire routing

     equipment7.12.1 Dependencies on more than one alarm signal - Type A7.12.2 Dependencies on more than one alarm signal - Type B7.12.3 Dependencies on more than one alarm signal - Type C7.13 Alarm counter  8.3 Fault signals from points9.5 Disablement of each address point10 Test conditionNotes:1) Scope of approval does not include the operation of the network functionality

    XFP501K/X/CON 1 Loop, 32 zone analogue addressable control and indicating equipment using ApolloProtocol + Keyswitch, metal housingIncorporating the following units:

     SPF0706000 Switch mode power supply board SPF0501211 XFP Apollo 1 loop, main motherboard SPF0501199 Display board "Keyswitch display"

    Certified with the following options with requirements from EN54-2: 19977.8 Output to fire alarm device(s)7.11 Delays to the actioning of outputs fire alarm devices and fire routing

     equipment7.12.1 Dependencies on more than one alarm signal - Type A7.12.2 Dependencies on more than one alarm signal - Type B7.12.3 Dependencies on more than one alarm signal - Type C7.13 Alarm counter  8.3 Fault signals from points9.5 Disablement of each address point10 Test condition

    176b/04

    Notes:1) Scope of approval does not include the operation of the network functionality

    XFP501E/H 1 Loop, 16 zone analogue addressable control and indicating equipment using Hochikiprotocol, plastic housingIncorporating the following units:

     SPF0702480 Switch mode power supply board SPF0501102 XFP Hochiki 1 loop, main motherboard

    Certified with the following options with requirements from EN54-2: 19977.8 Output to fire alarm device(s)7.11 Delays to the actioning of outputs fire alarm devices and fire routing

     equipment7.12.1 Dependencies on more than one alarm signal - Type A7.12.2 Dependencies on more than one alarm signal - Type B7.12.3 Dependencies on more than one alarm signal - Type C7.13 Alarm counter  8.3 Fault signals from points9.5 Disablement of each address point10 Test condition

    176b/05

    Notes:1) Scope of approval does not include the operation of the network functionality

    XFP501EK/H 1 Loop, 16 zone analogue addressable control and indicating equipment using Hochikiprotocol, plastic housing + KeyswitchIncorporating the following units:

     SPF0702480 Switch mode power supply board SPF1501102 XFP Hochiki 1 loop, main motherboard

    Certified with the following options with requirements from EN54-2: 19977.8 Output to fire alarm device(s)7.11 Delays to the actioning of outputs fire alarm devices and fire routing

     equipment7.12.1 Dependencies on more than one alarm signal - Type A7.12.2 Dependencies on more than one alarm signal - Type B7.12.3 Dependencies on more than one alarm signal - Type C7.13 Alarm counter  8.3 Fault signals from points9.5 Disablement of each address point

    10 Test condition

    176b/05

    Notes:1) Scope of approval does not include the operation of the network functionality

  • 8/16/2019 Redbook Vol1part1 2011

    35/389

    PART 1: SECTION 3CONTROL AND INDICATING EQUIPMENT

    24 Dec 2010 29

    Certificated Products LPCB Ref.No.

    XFP501E/X 1 Loop, 16 zone analogue addressable control and indicating equipment using ApolloProtocol, plastic housingIncorporating the following units:

     SPF0702480 Switch mode power supply board SPF0501101 XFP Apollo 1 loop, main motherboard

    Certified with the following options with requirements from EN54-2: 19977.8 Output to fire alarm device(s)7.11 Delays to the actioning of outputs fire alarm devices and fire routing

     equipment7.12.1 Dependencies on more than one alarm signal - Type A7.12.2 Dependencies on more than one alarm signal - Type B7.12.3 Dependencies on more than one alarm signal - Type C7.13 Alarm counter  8.3 Fault signals from points9.5 Disablement of each address point10 Test condition

    176b/06

    Notes:1) Scope of approval does not include the operation of the network functionality

    XFP501E/X/CON 1 Loop, 16 zone analogue addressable control and indicating equipment using ApolloProtocol, plastic housing

    Incorporating the following units: SPF0702480 Switch mode power supply board SPF0501101 XFP Apollo 1 loop, main motherboard

    Certified with the following options with requirements from EN54-2: 19977.8 Output to fire alarm device(s)7.11 Delays to the actioning of outputs fire alarm devices and fire routing

     equipment7.12.1 Dependencies on more than one alarm signal - Type A7.12.2 Dependencies on more than one alarm signal - Type B7.12.3 Dependencies on more than one alarm signal - Type C7.13 Alarm counter  8.3 Fault signals from points9.5 Disablement of each address point10 Test condition

    176b/06

    Notes:

    1) Scope of approval does not include the operation of the network functionalityXFP501EK/X 1 Loop, 16 zone analogue addressable control and indicating equipment using Apollo

    Protocol, plastic housing + KeyswitchIncorporating the following units:

     SPF0702480 Switch mode power supply board SPF1501101 XFP Apollo 1 loop, main motherboard

    Certified with the following options with requirements from EN54-2: 19977.8 Output to fire alarm device(s)7.11 Delays to the actioning of outputs fire alarm devices and fire routing

     equipment7.12.1 Dependencies on more than one alarm signal - Type A7.12.2 Dependencies on more than one alarm signal - Type B7.12.3 Dependencies on more than one alarm signal - Type C7.13 Alarm counter  8.3 Fault signals from points

    9.5 Disablement of each address point10 Test condition

    176b/06

    Notes:1) Scope of approval does not include the operation of the network functionality

    XFP501KE/X/CON One Loop, 16 zone analogue addressable control and indicating equipment using ApolloProtocol, Plastic housingIncorporating the following units:

     SPF0702480 Switch mode power supply board SPF1501101 XFP Apollo 1 loop, Main motherboard

    Certified with the following options with requirements from EN54-2: 19977.8 Output to fire alarm device(s)7.11 Delays to the actioning of outputs fire alarm devices and fire routing

     equipment7.12.1 Dependencies on more than one alarm signal - Type A7.12.2 Dependencies on more than one alarm signal - Type B

    7.12.3 Dependencies on more than one alarm signal - Type C7.13 Alarm counter  8.3 Fault signals from points

    176b/06

  • 8/16/2019 Redbook Vol1part1 2011

    36/389

    PART 1: SECTION 3CONTROL AND INDICATING EQUIPMENT

    30 24 Dec 2010

    Certificated Products LPCB Ref.No.

    9.5 Disablement of each address point10 Test conditionNotes:1) Scope of approval does not include the operation of the network functionality

    Certifi cate No: 176c to EN 54-2: 1997 + A1: 2006, EN 54-4: 1997 + A1: 2002 + A2: 2006 and EN 12094-1: 2003

    Certificated Products LPCB Ref.No.

    EP203 Conventional three zone class A 

    extinguisher control panel

    Incorporating the following units:

     SPF0000203 Main extinguisher control SPF0000212 External relay interface

     SPF0003613 Power supply unit SPF0000214 EP214 terminator  

     Incorporating as modular units:

     EP210S Remote Status Unit Surface Mount optional (See Note 1) EP211 Economy Status Unit optional (See Note 1)

    Certified with the following options with requirements from EN 12094-1:2003

     4.17 Delay of extinguishing signal 4.18 Signal representing the flow of extinguishing agent 4.19 Monitoring of the status of components 4.20 Emergency hold device 4.21 Control of flooding time 4.23 Manual only mode

     4.26 Triggering of equipment outside the system 4.27 Emergency abort device 4.30 Activation of alarm devices with different signals

    Certified with the following options with requirements from EN-54-2:1997

    7.8 Output to fire alarm device(s)7.11 Delays to the auctioning of outputs fire alarm devices and fire routingequipment7.13 Alarm counter  10 Test condition

    176c/01

    EP203/CON Conventional three zone class A 

    extinguisher control panel

    Incorporating the following units:

     SPF0000203 Main extinguisher control

     SPF0000212 External relay interface SPF0003613 Power supply unit SPF0000214 EP214 terminator  

    Incorporating as modular units:

     EP210S Remote Status Unit Surface Mount optional (See Note 1) EP211 Economy Status Unit optional (See Note 1)

    Certified with the following options with requirements from EN 12094-1:2003

     4.17 Delay of extinguishing signal 4.18 Signal representing the flow of extinguishing agent 4.19 Monitoring of the status of components 4.20 Emergency hold device 4.21 Control of flooding time

     4.23 Manual only mode 4.26 Triggering of equipment outside the system 4.27 Emergency abort device

    176c/01

  • 8/16/2019 Redbook Vol1part1 2011

    37/389

    PART 1: SECTION 3CONTROL AND INDICATING EQUIPMENT

    24 Dec 2010 31

    Certificated Products LPCB Ref.No.

     4.30 Activation of alarm devices with different signals

    Certified with the following options with requirements from EN-54-2:1997

    7.8 Output to fire alarm device(s)7.11 Delays to the auctioning of outputs fire alarm devices and fire routingequipment7.13 Alarm counter  10 Test condition

    Notes:1) Optional Remote Status Unit part No. EP21OS & Economy Status Unit part No. EP211 are not certified as meeting the requirements

    of the standards specified.2) Meets the requirements of EN12094-3:2003, Class A - i.e. operational temperature range of -5°C to +40°C.

    Control Equipment Limited

    Hillcrest Business Park, Dudley, West Midlands DY2 9AP UKTel: +44 (0)1384 458651 • Fax: +44 (0)1384 458972E-mail: [email protected] • Website: www.controlequipment.com

    Certifi cate No: 018a to BS 5839: Part 4. This certificate is to a withdrawn standard. Control and i ndicating equ ipmentconforming to this standard is not suitable for use within the jurisdiction of the European Union (EU). This certificate, to thewithdrawn standard, is maintained because control and indicating equipment meeting the withdrawn standard is still requestedby some regulators outside of the EU.Certificate No: 018c to EN 54: Part 2 and 4: 1997

    Certificated Products LPCB Ref.No.

    Precept 2 zone control and indicating equipmentIncorporating as modular units

    C1423 Motherboard

    C1440 Display Board

    018a/01

    Precept 4 zone control and indicating equipmentIncorporating as modular units

    C1423 Motherboard C1441 Display Board

    018a/02

    Precept 8 zone control and indicating equipmentIncorporating as modular units

    C1427 MotherboardC1462 Display Board

    018a/03

    Precept 16 zone control and indicating equipmentIncorporating as modular units

    C1425 MotherboardC1426 Display Board

    018a/04

    Precept 32 zone control and indicating equipmentIncorporating as modular units

    C1425 Motherboard

    C1426 Display BoardC1464 Display Board

    018a/05

    Series 600 2 zone control and indicating equipmentIncorporating as modular units

    C1423 MotherboardC1440 Display Board

    018a/06

    Series 600 4 zone control and indicating equipmentIncorporating as modular units

    C1423 MotherboardC1441 Display Board

    018a/07

    Series 600 8 zone control and indicating equipmentIncorporating as modular units

    C1427 MotherboardC1462 Display Board

    018a/08

    Series 600 16 zone control and indicating equipmentIncorporating as modular units

    C1425 MotherboardC1426 Display Board

    018a/09

    Series 600 32 zone control and indicating equipment 018a/10

  • 8/16/2019 Redbook Vol1part1 2011

    38/389

    PART 1: SECTION 3CONTROL AND INDICATING EQUIPMENT

    32 24 Dec 2010

    Certificated Products LPCB Ref.No.

    Incorporating as modular unitsC1425 MotherboardC1426 Display BoardC1464 Display Board

    Discovery 4 loop analogue addressable control and indicating equipmentIncorporating:

     A1579 Motherboard A1580 Display board A1585 Loop cards A1584 230 Vac power supply control card A1599 Printer board

    018c/01

    Precept En2 (2605-100) 2 zone conventional control and indicating equipmentIncorporating as modular units:-

     C1627 Mother board C1628 Display board C1631 Repeater interface board (option)

    018c/02

    Precept En4 (2605-101) 4 zone conventional control and indicating equipmentIncorporating as modular units:-

     C1627 Mother board C1628 Display board C1631 Repeater interface board (option)

    018c/03

    Precept En8 (2605-102) 8 zone conventional control and indicating equipmentIncorporating as modular units:-

     C1627 Mother board C1628 Display board C1631 Repeater interface board (option)

    018c/04

    Precept En16 (2605-103) 16 zone conventional control and indicating equipmentIncorporating as modular units:-

     C1627 Mother board C1628 Display board C1631 Repeater interface board (option)

    018c/05

    Precept En32 (2605-104) 32 zone conventional control and indicating equipmentIncorporating as modular units:-

     C1627 Mother board C1629 Display board C1631 Repeater interface board (option) C1632 16 Zone Expansion board

     C1652 5A Power supply board

    018c/06

    Precept En8 (2605-110) 8 zone conventional repeater unitIncorporating as modular units:-

     C1627 Mother board C1628 Display board C1631 Repeater interface board (option)

    018c/R01

    Precept En16 Repeater(2605-111)

    16 zone conventional repeater unitIncorporating as modular units:-

     C1627 Mother board C1628 Display board C1631 Repeater interface board (option)

    018c/R02

    Precept En32 Repeater(2605-112)

    32 zone conventional repeater unitIncorporating as modular units:-

     C1627 Mother board C1628 Display board C1631 Repeater interface board (option)

    018c/R03

    Certificate Nos. 018a and 018c:Certified with the following options from EN 54 Part 2:7.8 Output to fire alarm devices7.11 Delays to outputs8.3 Fault signals from points9.5 Disablement of addressable points10 Test condition

    Certificate Nos. 018c/02-06:Certified with the following options from EN 54 Part 2:7.8 Output to fire alarm devices7.9 Output to fire routing equipment7.10 Output to automatic fire protection equipment7.11 Delays to outputs8.9 Output to fault warning equipment

    10 Test condition

  • 8/16/2019 Redbook Vol1part1 2011

    39/389

    PART 1: SECTION 3CONTROL AND INDICATING EQUIPMENT

    24 Dec 2010 33

    Certifi cate No: 018n to EN 54-4: 1997 + A1: 2002 + A2: 2006

    Power Supply Unit

    Certificated Products LPCB Ref.No.

    2605467 Fireclass 1.9A Power Supply Unit 018n/01Note: The unit is not intended to supply power to Fire Alarm Control Panels

    Cooper Industries IncWheatley Hall Road, Doncaster, South Yorkshire DN2 4NB UKTel: +44 (0)1302 303303 • Fax: +44 (0)1302 367155E-mail: [email protected] • Website: www.cooper-ls.com

    UK Sales:

    Menvier & JSBTel: +44 (0)1302 303202 • Fax: +44 (0)1302 367155E-mail: [email protected] • Website: www.cooper-ls.com

    UK Sales:Tel: +44 (0)1594 541900 • Fax: +44 (0)1594 541910E-mail: [email protected] • Website: www.cooperfire.co.uk

    Certificate No: 714a to EN 54 Part 2 and 4 :1997

    Certificated Products LPCB Ref.No.CF3000 Analogue addressable 2 and 4 loop Control and indicating equipment

    Incorporating the following units: ADF6 Assembled back box YPCB2153 Motherboard PCB YPCB2147 PSU PCB YPCB2148 2 Loop card (2 off) ADF6 Screen Touch Screen YPCB2185 Complete Display + Micro PCB ADF6DISPCOVER Display PCB Cover  ADF6FACIA Front Moulding ADF6PRINTDOOR Printer Door Moulding BAT-NP12-12 Batteries (2 off) ADF6HINGE Door Hinges ADF6OPFACIA Optional Anti Tamper Cover 

     ADF6PRINTER Printer  YPCB2187 Fire Brigade Interface

    714a/01

    Certified with the following options from EN 54 Part 2: 7.8 Output to fire alarm device(s) 7.9 Output to fire alarm routing equipment 7.10 Output to automatic fire protection equipment 7.11 Delays to the actioning of outputs fire alarm devices and fire routing

     equipment 7.12 Coincidence detection 7.13 Alarm counter   8.9 Output to fault warning routing equipment 9.5 Disablement of each address point 10 Test condition

    DF6000 Analogue addressable 2 and 4 loop control and indicating equipmentIncorporating the following units:

     ADF6 Assembled back box YPCB2153 Motherboard PCB YPCB2147 PSU PCB YPCB2148 2 Loop card (2 off)

    714a/01

  • 8/16/2019 Redbook Vol1part1 2011

    40/389

    PART 1: SECTION 3CONTROL AND INDICATING EQUIPMENT

    34 24 Dec 2010

    Certificated Products LPCB Ref.No.

     ADF6Screen Touch Screen YPCB2185 Complete Display + Micro PCB ADF6DISPCOVER Display PCB Cover  ADF6FACIA Front Moulding ADF6PRINTDOOR Printer Door Moulding BAT-NP12-12 Batteries (2 off) ADF6HINGE Door Hinges ADF6OPFACIA Optional Anti Tamper Cover  ADF6PRINTER Printer  YPCB2187 Fire Brigade Interface

    Certified with the following options from EN 54 Part 2: 7.8 Output to fire alarm device(s) 7.9 Output to fire alarm routing equipment 7.10 Output to automatic fire protection equipment 7.11 Delays to the actioning of outputs fire alarm devices and fire routing

     equipment 7.12 Coincidence detection 7.13 Alarm counter   8.9 Output to fault warning routing equipment 9.5 Disablement of each address point 10 Test condition

    FX6000 Analogue addressable 2 and 4 Loop control and indicating equipmentIncorporating the following units:

     ADF6 Back Assembled back box YPCB2153 Motherboard PCB YPCB2147 PSU PCB YPCB2148 2 Loop Card (2 off) ADF6Screen Touch Screen YPCB2185 Complete Display + Micro PCB ADF6 DISPCOVER Display PCB Cover  ADF6FACIA Front Moulding ADF6PRINTDOOR Printer Door Moulding BAT-NP12-12 Batteries (2 off) ADF6HINGE Door Hinges ADF6OPFACIA Optional Anti Tamper Cover  ADF6PRINTER Printer  YPCB2187 Fire Brigade Interface

    714a/01

    Certified with the following options from EN 54 Part 2: 7.8 Output to fire alarm device(s) 7.9 Output to fire alarm routing equipment 7.10 Output to automatic fire protection equipment 7.11 Delays to the actioning of outputs fire alarm devices and fire routing

     equipment 7.12 Coincidence detection 7.13 Alarm counter   8.9 Output to fault warning routing equipment 9.5 Disablement of each address point 10 Test condition

    CF2000 Analogue addressable 2 Loop control and indicating equipmentIncorporating the following units:

     PR202-50-2209 Power supply board PR202-50-2206 Main motherboard PR202-50-2205 Display board

    714a/02

    Certified with the following options from EN 54 Part 2: 7.8 Output to fire alarm device(s) 7.9 Output to fire alarm routing equipment 7.10 Output to automatic fire protection equipment 7.11 Delays to the actioning of outputs fire alarm devices and fire routing

     equipment 7.12 Coincidence detection 7.13 Alarm counter   8.9 Output to fault warning routing equipment 9.5 Disablement of each address point