3
03 001 Plan, Section & Elevation SCALE 1 : 20 @ A3 Issued For Comment/Approval ƒ Headbox sizes are dependent on the curtain width & drop as specified below. ƒ Please see relevant specifications for product size limits. Rev. Date Initial AS NOTED 4 OF 9 DRAWING NUMBER PROJECT: DESCRIPTION: A3 ALL DIMENSIONS IN MILLIMETRES UNLESS STATED OTHERWISE. DO NOT SCALE. IF IN DOUBT ASK. 6<67(0 72/(5$1&( ,6 0,//,0(75(6 ,1 $1< 3/$1( 81/(66 27+(5:,6( 63(&,),(' NOTHING IS TO BE FIXED TO THE ROLLER HOUSING WITHOUT PRIOR BLE CONSENT. ALL PRINTED DRAWINGS ARE UNCONTROLLED . COPYRIGHT This Document is the copyright of BLE Smoke & Fire Curtains Ltd. and contains confidential information. It may not be copied, transmitted or information made known to any third party without the permission of BLE Smoke & Fire Curtains Ltd. Description '5$:,1* ʋ Tel :- +44 (0) 114 251 4703 Fax :- +44 (0) 114 251 3908 Email :- [email protected] STANDARD SYSTEMS BLE-SSD-113 BLE-SSD-113 C. DAUBNEY 14.03.18 R. CAMERON 15.03.18 SC1 / SD60 TYPE A SINGLE ROLLER SMOKE CURTAIN DETAILS 03 001 Plan Section Of Through Headbox SCALE 1 : 5 @ A3 04 001 SCALE 1 : 5 @ A3 NOTES: 03 001 04 001 02 001 02 001 Section Through Headbox SCALE 1 : 3 @ A3 Plan Section Of Through Headbox Rear Access. Curtain Side Access. Additional Information RAL Colour Headbox Powder Coating RAL Colour Sideguide Powder Coating RAL Colour Bottom Bar Powder coating Guides Face Fixed with Caps Guides Face Fixed with Angles X

Rear Access. Curtain Side Access. Headbox Powder Coating RAL …€¦ · SMOKE CURTAIN DETAILS 03 001 Plan Section Of Through Headbox SCALE 1 : 5 @ A3 04 001SCALE 1 : 5 @ A3 NOTES:

  • Upload
    others

  • View
    2

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Rear Access. Curtain Side Access. Headbox Powder Coating RAL …€¦ · SMOKE CURTAIN DETAILS 03 001 Plan Section Of Through Headbox SCALE 1 : 5 @ A3 04 001SCALE 1 : 5 @ A3 NOTES:

03001

Plan, Section & ElevationSCALE 1 : 20 @ A3

Issued For Comment/Approval

▪ Headbox sizes are dependent on thecurtain width & drop as specified below.

▪ Please see relevant specifications forproduct size limits.

Rev. Date Initial

AS NOTED

4 OF 9

DRAWING NUMBER

PROJECT:

DESCRIPTION:

A3

ALL DIMENSIONS IN MILLIMETRES UNLESS STATED OTHERWISE. DO NOT SCALE. IF IN DOUBT ASK.SYSTEM TOLERANCE IS ±5 MILLIMETRES IN ANY PLANE UNLESS OTHERWISE SPECIFIED.NOTHING IS TO BE FIXED TO THE ROLLER HOUSING WITHOUT PRIOR BLE CONSENT.

ALL PRINTED DRAWINGS ARE UNCONTROLLED .

COPYRIGHT © This Document is the copyright of BLE Smoke & Fire Curtains Ltd. and containsconfidential information. It may not be copied, transmitted or information made known to anythird party without the permission of BLE Smoke & Fire Curtains Ltd.

Description

DRAWING №:

Tel :- +44 (0) 114 251 4703Fax :- +44 (0) 114 251 3908Email :- [email protected]

STANDARD SYSTEMS

BLE-SSD-113

BLE-SSD-113

C. DAUBNEY 14.03.18

R. CAMERON 15.03.18

SC1 / SD60 TYPE ASINGLE ROLLER

SMOKE CURTAIN DETAILS

03001

Plan Section Of Through HeadboxSCALE 1 : 5 @ A3

04001 SCALE 1 : 5 @ A3

NOTES:

03001

04001

02001

02001

Section Through HeadboxSCALE 1 : 3 @ A3

Plan Section Of Through Headbox

Rear Access.Curtain Side Access.

Additional Information

RAL ColourHeadbox Powder Coating

RAL ColourSideguide Powder Coating

RAL ColourBottom Bar Powder coating

Guides Face Fixed with CapsGuides Face Fixed with Angles

X

Page 2: Rear Access. Curtain Side Access. Headbox Powder Coating RAL …€¦ · SMOKE CURTAIN DETAILS 03 001 Plan Section Of Through Headbox SCALE 1 : 5 @ A3 04 001SCALE 1 : 5 @ A3 NOTES:

03001

Plan, Section & ElevationSCALE 1 : 20 @ A3

Issued For Comment/Approval

▪ Headbox sizes are dependent on thecurtain width & drop as specified below.

▪ Please see relevant specifications forproduct size limits.

▪ If curtain is to be mitred there must bean odd number of rollers in eachheadbox.

Rev. Date Initial

AS NOTED

5 OF 9

DRAWING NUMBER

PROJECT:

DESCRIPTION:

A3

ALL DIMENSIONS IN MILLIMETRES UNLESS STATED OTHERWISE. DO NOT SCALE. IF IN DOUBT ASK.SYSTEM TOLERANCE IS ±5 MILLIMETRES IN ANY PLANE UNLESS OTHERWISE SPECIFIED.NOTHING IS TO BE FIXED TO THE ROLLER HOUSING WITHOUT PRIOR BLE CONSENT.

ALL PRINTED DRAWINGS ARE UNCONTROLLED .

COPYRIGHT © This Document is the copyright of BLE Smoke & Fire Curtains Ltd. and containsconfidential information. It may not be copied, transmitted or information made known to anythird party without the permission of BLE Smoke & Fire Curtains Ltd.

Description

DRAWING №:

Tel :- +44 (0) 114 251 4703Fax :- +44 (0) 114 251 3908Email :- [email protected]

STANDARD SYSTEMS

BLE-SSD-114

BLE-SSD-114

C. DAUBNEY 14.03.18

R. CAMERON 14.03.18

SC1 / SD60 TYPE BSIDE BY SIDE MULTI-BARREL

SMOKE CURTAIN DETAILS

03001

Plan Section Of Through HeadboxSCALE 1 : 5 @ A3

04001 SCALE 1 : 5 @ A3

NOTES:

03001

04001

02001

02001

Section Through HeadboxSCALE 1 : 3 @ A3

Plan Section Of Through Headbox

Rear Access.Curtain Side Access.

Additional Information

RAL ColourHeadbox Powder Coating

RAL ColourSideguide Powder Coating

RAL ColourBottom Bar Powder coating

Guides Face Fixed with CapsGuides Face Fixed with Angles

Page 3: Rear Access. Curtain Side Access. Headbox Powder Coating RAL …€¦ · SMOKE CURTAIN DETAILS 03 001 Plan Section Of Through Headbox SCALE 1 : 5 @ A3 04 001SCALE 1 : 5 @ A3 NOTES:

01001

Plan, Section & ElevationSCALE 1 : 20 @ A3

Issued For Comment/Approval

▪ Headbox sizes are dependent on thecurtain width & drop as specified below.

▪ Please see relevant specifications forproduct size limits.

Rev. Date Initial

AS NOTED

6 OF 9

DRAWING NUMBER

PROJECT:

DESCRIPTION:

A3

ALL DIMENSIONS IN MILLIMETRES UNLESS STATED OTHERWISE. DO NOT SCALE. IF IN DOUBT ASK.SYSTEM TOLERANCE IS ±5 MILLIMETRES IN ANY PLANE UNLESS OTHERWISE SPECIFIED.NOTHING IS TO BE FIXED TO THE ROLLER HOUSING WITHOUT PRIOR BLE CONSENT.

ALL PRINTED DRAWINGS ARE UNCONTROLLED .

COPYRIGHT © This Document is the copyright of BLE Smoke & Fire Curtains Ltd. and containsconfidential information. It may not be copied, transmitted or information made known to anythird party without the permission of BLE Smoke & Fire Curtains Ltd.

Description

DRAWING №:

Tel :- +44 (0) 114 251 4703Fax :- +44 (0) 114 251 3908Email :- [email protected]

STANDARD SYSTEMS

BLE-SSD-115

BLE-SSD-115

C. DAUBNEY 14.03.18

R. CAMERON 15.03.18

SC1 / SD60 TYPE COVER-UNDER MULTI-BARREL

SMOKE CURTAIN DETAILS

03001

Plan Section Of Through HeadboxSCALE 1 : 5 @ A3

04001 SCALE 1 : 5 @ A3

NOTES:

03001

04001

02001

02001

Section Through HeadboxSCALE 1 : 3 @ A3

Plan Section Of Through Headbox

Rear Access.Curtain Side Access.

Additional Information

RAL ColourHeadbox Powder Coating

RAL ColourSideguide Powder Coating

RAL ColourBottom Bar Powder coating

Guides Face Fixed with CapsGuides Face Fixed with Angles

X