14 Crosshill Road, Crumlin, Co. Antrim, Northern Ireland
Re-Grip Ultra Plate
14 Crosshill Road, Crumlin, Co. Antrim, Northern Ireland
Our Re-Grip ULTRA Plate has been designed for high footfall applications. The plate system can be retrofitted onto existing structures such as walk-ways, bridges, ramps and factory floors to provide a high slip resistant and safe pedestrian walking area.
Our Re-Grip ULTRA Plate is non-porous, resists dirt build up, is easily cleaned and can withstand aggressive cleaning agents. The GRP Plate can be easily retrofitted onto existing concrete, steel or timber structures, and further provides a safe and durable alternative to steel and plastic anti-slip products.
STANDARD
LENGTH WIDTH (mm) THICKNESS COLOUR EMBEDDED GRIT SURFACE TYPE OF RASIN
1000 mm 1000 4mm Black with
Yellow/White Nosing
Medium General Purpose
2000 mm 1000 4mm Black with Yellow/White
Nosing
Medium General Purpose
BESPOKE
Up to 4000 Up to 345 4+ Any 2 RAL or
BS Codes Fine, Medium, Heavy
Duty
General Purpose Chemical Re-
sistant, Fire Re-sistant (Class 0, 1
& 2 under BS476)
Re-Grip Ultra Plate Information
The HSE Pendulum Slip Testing concluded that Relinea’s GRP Re-Grip Ultra and Re-Grip Anti-Slip products achieved the highest slip resistant classification of ‘Extremely Low’ pedestrian slip risk.
Pendulum Slip Test Data
PENDULUM TEST VALUE (PTV) SLIP RISK
0—24 High
25—35 Moderate
36—64 Low
65+ Extremely Low
Re-Grip Ultra Plate
14 Crosshill Road, Crumlin, Co. Antrim, Northern Ireland
Preparation
Ensure area is clean and dry, and free from loose and defective material. Any damaged surface areas should be patch repaired to provide a reasonably flat and consistent surface.
Installation
Drill holes 15mm in from all edges at approx. 500mm centres. Depending on the width of the Re-Grip ULTRA Plate, it may be necessary to provide fixing points also at 500mm centres down the middle. Mechanical fixings and gap filling adhesive are advised to be used.
Recommended Mechanical Fixings
For wet and external applications we recommend the use of stainless steel fixings.
All fasteners should feature low profile heads such as Truss Heads.
1. Fixing onto Timber
Stainless Steel Flange Head Pozi 4.8 x 19mm
2. Fixing onto Steel Plate
Stainless Steel Rivets – 4.8 x 25mm
• Align and position the Re-Grip ULTRA Plate over the Steel Plate.
• Using a powered screw driver and M5 bit, drill through both, creating enough holes to permanently fix the Re-Grip ULTRA Stair Tread Cover.
• Using a rivet gun, affix the Re-Grip ULTRA Plate to the Steel Plate.
3. Fixing onto Concrete
50 x 6mm stainless steel hammer fixings
• Using a masonry drill bit, drill through the Re-Grip ULTRA Plate and into the substrate the required depth.
• Hammer fix in for a secure fit.
• If the fixing needs to be removed simply unscrew and remove. The fixing can be re-used if it has not been bent or plug lost.
Re-Grip Ultra Plate Installation
Relinea’s Pendulum Test Results
COEFFICIENT OF FRICTION (CoF) RELINEA GRP ANTI-SLIP RANGE
DRY WET
Re-Grip Ultra 97 79
Re-Grip 97 76
14 Crosshill Road, Crumlin, Co. Antrim, Northern Ireland
DEPTH(MM)
SPAN(MM)3
CONCENTRATED LOAD – FULL PANEL1 UNIFORM LOAD – FULL PANEL Concentrated load to pro-
duce 1% deflection of
span (Kg)
MAX LOAD(KG)2
LOAD (KG) MAX LOAD(KG/M2)
LOAD (KG/M2)
DEFLECTION (MM) DEFLECTION (MM)
Firm 45 113 225 340 450 Firm 122 244 366 488 732
6
300 61 1.2 2.6 5.0 7.4 9.9 928 0.2 0.5 0.6 0.9 1.1 136
450 53 2.0 4.6 8.9 - - 242 1.4 2.6 2.9 3.9 5.2 116
600 52 2.5 6.8 - - - 69 4.5 9.0 12.1 - 0 101
900 24 8.8 - - - - - - - - - 0 46
9
300 147 0.4 1.1 2.3 3.5 4.8 1366 <0.1 <0.1 0.4 0.8 0.8 302
450 130 0.7 1.9 4.0 6.0 8.1 418 0.6 1.5 1.9 2.9 3.8 264
600 67 2.5 4.9 9.0 - - 188 1.9 4.1 5.8 8.0 11.4 135
900 44 4.5 11.8 - - - 76 6.5 - - - - 87
12
300 272 0.1 0.2 0.9 1.9 2.5 1859 <0.1 <0.1 0.3 0.8 5.6 567
450 246 0.2 0.6 1.2 2.0 3.1 592 0.3 1.4 1.5 2.3 2.7 537
600 141 1.0 2.4 3.7 7.1 9.5 328 1.3 2.6 3.3 4.6 6.2 286
900 71 3.2 7.1 - - - 138 3.9 7.9 11.3 - - 144
19
300 1119 0.1 0.1 0.3 0.4 0.6 5514 <0.1 <0.1 0.1 0.2 0.2 2154
450 509 0.2 0.6 1.0 1.6 2.0 1637 <0.1 0.4 0.5 1.0 1.0 970
600 400 0.4 1.0 1.9 2.6 3.3 689 0.8 1.7 1.9 2.9 3.4 771
900 314 0.6 1.6 3.2 4.7 6.1 246 2.0 3.8 4.8 6.5 8.2 653
1 Full Panel—Based on 1m length
2 Firm Max Load—The load that will produce L/d of 200 or 6mm max deflection, whichever is the lowest.
3 Clear Span is calculated as50mm less than the width of grating
PLATE WEIGHT (APPROX.)
6mm thick—14kg/m2
9mm thick—20kg/m2
12mm thick—27kg/m2
Re-Grip Ultra Plate Load Table
Load Table
Gap Filling Adhesive
Apply a 6mm bead of the high strength gap-filling adhesive around the periphery of the panel, and in horizontal stripes at approximately 250mm centres. Press the panel firmly to the substrate immediately, to ensure adequate transfer of the adhesive. Secure with the mechanical fixings, and allow the adhesive sealant to cure before allowing excessive traffic to use the areas. Under normal circumstances and condi-tions, a firm bond will be achieved in about 1 hour
14 Crosshill Road, Crumlin, Co. Antrim, Northern Ireland
SECTION 1
Product and Company Identification
Emergency phone number
Product
PPE
+44 (0) 28 9447 0010
Re-Grip Ultra Plate in Standard Polyester, Isophthalic and Vinylester fire retardant resin..
Refer to MSDS Section 8, Control Measures
SECTION 2
Chemical Ingredients
Chemical Component
Glass Reinforced Plastic
Polymerized Resin
Fiberglass Strand
Silica Sand
Percentage
N/A
50—55
35—55
10 – 15
SECTION 3
Physical & Chemical
Properties
Boiling Point
Vapour Pressure
Vapour Density
Melting Point
Evaporation Rate
Solubility in Water
Appearance and Odour
Measurement
N/A
N/A
N/A
N/A
N/A
None
Various coloured meshes and solid shapes. Low to no odour
SECTION 4
Fire and Explosion Data
Flash Point
Flammable Limits
Extinguishing Media
Special Firefighting Procedures
Unusual fire & explosion hazards
LEL
UEL
N/A
N/A
Water, Foam Type A, B or C extinguishers
Use Self-Contained Breathing Apparatus (SCBA) with full face operated in pressure mode
Burning FRP creates a complex mixture of solid, liquid, particulate and gases. Carbon Monoxide and other organic compounds may be given off
N/A
N/A
SECTION 5
Reactivity Data
Stability
Conditions to Avoid
Incompatibility
Hazardous Decomposition or By Products
Hazardous Polymerization
Stable
Sources of ignition, sparks or flames, extremely high temperatures
Strong oxidising acid
N/A
Will not occur
Material Safety Data
Re-Grip Ultra Plate Data Sheet
14 Crosshill Road, Crumlin, Co. Antrim, Northern Ireland
SECTION 6
Health Hazard Data
Routes to Entry
Health Hazards
Carcinogenicity
Signs & Symptoms of Exposure
Medical Conditions Generally Aggravated by Exposure
Emergency and First Aid Procedures
Inhalation—X Skin—X Ingestion—X
Dust from cutting may act as a mechanical irritant to skin, eyes and upper respiratory system. Vapours or products of thermal degrada-tion generated by cutting or grinding may aggravate or cause respir-atory conditions.
NTP – N/A IARC Monographs – N/A OSHA – N/A
Temporary Irritation and itching to skin or eyes. Scratchiness or burning of the nose and/or throat if exposed to large amounts of airborne dust from cutting or machining.
Chronic Dermatitis or respiratory conditions
Wash skin well without rubbing. For eyes, use a sterile solution and flood the eye area. Change clothing after exposure. Apply antiseptic to any abraded skin area.
SECTION 7
Spill or Leak Procedures
Steps to be taken in case material is released or spilled
Water Disposal Method
Other Precautions
No material is released in the product’s solid form. However, when cutting, grinding or machining, if airborne dust is generated, the wearing of respirators is recommended. Control and collect any dust. Place in sturdy containers for proper disposal.
Control and collect any dust generated in sturdy containers to pre-vent dispersal. Dispose of in accordance with all local and govern-ment regulations. Generally the dust is not considered a hazardous waste.
Do not allow dust to go uncontrolled
SECTION 8
Control Measures
Respiratory Protection Ventilation
Protective Gloves
Eye Protection
Other Protective Equipment
Work Hygienic Practices
Approved for dusts and mists not less than 00.1mg/m3
Mechanical dust collector with local exhaust recommended at point of generation of any dust due to cutting or grinding.
Wear gloves when handling product to prevent cuts, scratches or abrasions
Wear protective eye wear with side shields or ventilated goggles when cutting or grinding.
Long sleeve shirts with closed collars, long trousers or protective clothing may be worn to prevent dust exposure when cutting or grinding product
Use personal protection equipment to minimize skin, respiratory and eye exposure to dust and fumes when cutting or grinding prod-uct. Wash all exposed skin areas thoroughly after cutting or grinding. Launder clothing separately and frequently to prevent skin expo-
We believe that the above information is valid and reliable. The information, however, is provided with-out any representation of warranty, express or implied regarding the accuracy of correctness. The condi-tions of methods of handling, storage, use, cutting, grinding, disposal, or any other use of the product are beyond our control. For this and other reasons, we do not assume responsibility and expressly disclaim liability for loss, damage or expense arising out of or in any way connected with the handling, storage, use, cutting, grinding, disposal or any other use of this product.
Re-Grip Ultra Plate Data Sheet