3
 Instrumentation Cable EN 50288-7 Flame Retardant, Sunlight Resistant  90 °C / 300 V Single & Multi-Pair, XLPE-Insulation, Collective Screen, Armour, PVC-Sheath  RE-2X(St)YQY-fl Tech nical datasheet © LEONI Kerpen GmbH · Phone: +49 24 02 17 307 · www.leon i-industri al-projects.com Date of issue: 2014-05-05 Transfer to third parties only by authority of LEONI Kerpen GmbH Printing errors excepted. Subject to alterations. Creator: LK Page: 1/2 7E02020000_EN_50288-7_300_2_-30_90_RE-2X(St)YQY-fl_black_stranded_Printdate.pdf Application For transmission of analogue and digital signals in instrument and control systems; allowed for use in zone 1 and zone 2 group II classified areas (IEC 60079-14); not allowed for direct connection to low impedance source, e.g. the public mains electricity supply. Recommended for indoor and outdoor installation, on racks, trays, in conduits, in dry and wet locations; for direct burial. Construction Conducto r................................ plain annealed copper wire, stranded, size: 0.5 mm 2 , 0.75 mm 2 , 1 mm 2 , 1.3 mm 2 , 1.5 mm 2 , 2.5 mm 2 Insulation.................................. cross-linked polyethylene XLPE Colour code.............................. black / white, continuously numbered on white core (1, 2, 3..) for multi-ele- ment Wrapping.................................. at least 1 layer of plastic tape Collective screen...... ................ 24 µm aluminium / PETP tape over tinned copper drain wire, 0.5 mm 2 Inner sheath............................. polyvinyl chloride PVC, black  Armour... .................................. galvanised steel wire braid, opt. coverage 80% (min.) Outer sheath.... ........................ polyvinyl chloride PVC, black, blue for intrinsically safe systems Cable marking.......................... LEONI KERPEN ICON INSTRUMENTATION CABLE SIZE 300V RP EN 50288-7 CE PRODUCTION LOT CODE LENGTH MARKING Technical data Abbreviations Flame propagation - Test on single cable IEC 60332-1-2 - Test on bunched cables IEC 60332-3-24 (Cat. C) Limiting Oxygen Index (LOI)  ASTM D 2 863 (min. 30 %) Flammability temperature (FT) ISO 4589-3 ann. A (min. +250 ° C)  Amount o f haloge n acid ga s IEC 60754-1 (max. 23 %) Oil resistance ICEA S-73-532 Sunlight resistance UL 1581 section 1200 T emperature r ange -30°C up to +90°C (during operation) -5°C up to +50°C (during installation) Minimum bending radius 10 x cable diameter RE- Instrumentation Cable 2X XLPE insulation (St) collective screen Y PVC inner sheath Q steel wire braid Y PVC outer sheath -fl reduced flame propagation Electrical Properties at 20 °C Conductor cross-section nom. mm 2 0.5 0.75 1 1.3 1.5 2.5 Conductor resistance max. Ω/km 36.7 25.0 18.5 14.2 12.3 7.6 Insulation resistance min. MΩ x km 5000 Mutual capacitance single element: 2 to 4 elements: above 4 elements: max. nF/km 115 90 75  115 90 75  115 90 75  11 5 102 85  11 5 102 85  11 5  Inductance max. mH/km 1 Capacitance unbalance max. pF/500 m 500 L/R ratio max. µH/Ω 25 40 60 Test voltage U rms  (core : core) V 1500 Test voltage U rms  (core : screen) V 1500 Operating voltage V 300

RE-2X(ST)YQY-FL

Embed Size (px)

DESCRIPTION

hi

Citation preview

  • Instrumentation Cable EN 50288-7

    Flame Retardant, Sunlight Resistant

    90 C / 300 VSingle & Multi-Pair, XLPE-Insulation, Collective Screen, Armour, PVC-Sheath RE-2X(St)YQY-fl

    Technical datasheet LEONI Kerpen GmbH Phone: +49 24 02 17 307 www.leoni-industrial-projects.comDate of issue: 2014-05-05 Transfer to third parties only by authority of LEONI Kerpen GmbH

    Printing errors excepted. Subject to alterations.Creator: LK

    Page: 1/27E02020000_EN_50288-7_300_2_-30_90_RE-2X(St)YQY-fl_black_stranded_Printdate.pdf

    ApplicationFor transmission of analogue and digital signals in instrument and control systems; allowed for use in zone 1 and zone 2 group II classified areas (IEC60079-14); not allowed for direct connection to low impedance source, e.g. the public mains electricity supply.Recommended for indoor and outdoor installation, on racks, trays, in conduits, in dry and wet locations; for direct burial.ConstructionConductor................................ plain annealed copper wire, stranded, size: 0.5 mm2, 0.75 mm2, 1 mm2,

    1.3 mm2, 1.5 mm2, 2.5 mm2

    Insulation.................................. cross-linked polyethylene XLPEColour code.............................. black / white, continuously numbered on white core (1, 2, 3..) for multi-ele-

    mentWrapping.................................. at least 1 layer of plastic tapeCollective screen...................... 24 m aluminium / PETP tape over tinned copper drain wire, 0.5 mm2

    Inner sheath............................. polyvinyl chloride PVC, blackArmour..................................... galvanised steel wire braid, opt. coverage 80% (min.)Outer sheath............................ polyvinyl chloride PVC, black, blue for intrinsically safe systemsCable marking.......................... LEONI KERPEN ICON INSTRUMENTATION CABLE SIZE 300V RP EN

    50288-7 CE PRODUCTION LOT CODE LENGTH MARKINGTechnical data AbbreviationsFlame propagation- Test on single cable IEC 60332-1-2- Test on bunched cables IEC 60332-3-24 (Cat. C)Limiting Oxygen Index (LOI) ASTM D 2863 (min. 30 %)Flammability temperature (FT) ISO 4589-3 ann. A (min. +250 C)Amount of halogen acid gas IEC 60754-1 (max. 23 %)Oil resistance ICEA S-73-532Sunlight resistance UL 1581 section 1200

    Temperature range-30C up to +90C(during operation)-5C up to +50C(during installation)Minimum bending radius10 x cable diameter

    RE- Instrumentation Cable2X XLPE insulation(St) collective screenY PVC inner sheathQ steel wire braidY PVC outer sheath-fl reduced flame propagation

    Electrical Properties at 20 CConductor cross-section nom. mm2 0.5 0.75 1 1.3 1.5 2.5Conductor resistance max. /km 36.7 25.0 18.5 14.2 12.3 7.6Insulation resistance min. M x km 5000Mutual capacitancesingle element:2 to 4 elements:above 4 elements:

    max. nF/km 1159075

    1159075

    1159075

    11510285

    11510285

    115

    Inductance max. mH/km 1Capacitance unbalance max. pF/500 m 500L/R ratio max. H/ 25 40 60Test voltage Urms (core : core) V 1500Test voltage Urms (core : screen) V 1500Operating voltage V 300

  • Instrumentation Cable EN 50288-7

    Flame Retardant, Sunlight Resistant

    90 C / 300 VSingle & Multi-Pair, XLPE-Insulation, Collective Screen, Armour, PVC-Sheath RE-2X(St)YQY-fl

    Technical datasheet LEONI Kerpen GmbH Phone: +49 24 02 17 307 www.leoni-industrial-projects.comDate of issue: 2014-05-05 Transfer to third parties only by authority of LEONI Kerpen GmbH

    Printing errors excepted. Subject to alterations.Creator: LK

    Page: 2/27E02020000_EN_50288-7_300_2_-30_90_RE-2X(St)YQY-fl_black_stranded_Printdate.pdf

    Geometrical dataNo. of

    elementsRT of

    insulationRT of inner

    sheathDia. over

    inner sheathDia. of

    armour wireRT of outer

    sheathOuter dia. Weight Part No.

    nom. nom. approx. nom. nom. approx. approx. Colour(mm) (mm) (mm) (mm) (mm) (mm) (kg/km) black

    0.5 mm2/71 0.35 0.8 5.2 0.3 1.3 9.1 123 LKX7331E00100004 0.35 1.0 9.0 0.3 1.4 13.1 235 LKX7331E0070000

    12 0.35 1.2 13.7 0.3 1.5 18.0 437 LKX7331E01900000.75 mm2/7

    1 0.38 0.8 5.6 0.3 1.3 9.5 135 LKX7331E03100004 0.38 1.0 10.0 0.3 1.4 14.1 272 LKX7331E0370000

    12 0.38 1.2 15.3 0.3 1.6 19.8 537 LKX7331E04900001 mm2/7

    1 0.40 0.9 6.3 0.3 1.3 10.2 153 LKX7331E06100004 0.40 1.1 11.1 0.3 1.4 15.2 318 LKX7331E0670000

    12 0.40 1.3 17.0 0.3 1.6 21.5 643 LKX7331E07900001.3 mm2/7

    1 0.45 0.9 6.8 0.3 1.3 10.7 169 LKX7331E09100004 0.45 1.1 12.2 0.3 1.5 16.5 374 LKX7331E0970000

    12 0.45 1.4 19.1 0.3 1.7 23.8 169 LKX7331E10900001.5 mm2/7

    1 0.45 0.9 7.1 0.3 1.3 11.0 181 LKX7331E12100004 0.45 1.1 12.7 0.3 1.5 17.0 402 LKX7331E1270000

    12 0.45 1.4 19.9 0.3 1.7 24.6 856 LKX7331E13900002.5 mm2/7

    1 0.55 0.0 0.0 0 0.0 0.0 0 LKX7331E9550000RT = Radial Thickness