1
CABLE TERMINATION & ACCESSORIES א 04 4-21 JOINTS For jointing cables upto 36KV Raychem offers a system based on heat shrinkable materials which is; fast and simple to install, eliminates shelf life limitations, and offers high impact resistance and high earth fault current capacity. Millions of cable joints upto 36KV installed in some of the most severe service condition have confirmed the reliability of Raychem design under high electrical, thermal, and environmental stress. Catalog Number Conductor Size Upto 1KV/Plastic Four Conductors (Not Armoured) List Price (Wire Armoured) mm² ESIJ-OX/4C 1.5-6 / NA ESIJ-OX/4C 6-16 / NA ESIJ-OX/4C 16-35/ NA ESIJ-OX/4C 35-70 / NA ESIJ-OX/4C 70-150 / NA ESIJ-OX/4C 150-300 / NA 76.00 89.00 128.00 237.00 399.00 386.00 ESIJ-OX/4C 1.5-6 / SA ESIJ-OX/4C 6-16 / SA ESIJ-OX/4C 25-50/SA ESIJ-OX/4C70-150/SA ESIJ-OX/4C185-300/SA 1.5-6 6-16 25-50 70-150 185-300 Catalog Number Conductor Size Upto 7.2 ,KV/Plastic One Conductor (Without Armour) mm² ESIJ-2X/1C 25-50 / NA ESIJ-2X/1C 70-120 / NA ESIJ-2X/1C 150-185 / NA ESIJ-2X/1C 240-300 / NA 25-50 70-120 150-185 240-300 Catalog Number Conductor Size Upto 7.2KV/Plastic Three Conductors (Without Armour) (With Armour) mm² ESIJ-2X/3C 25-50 / NA ESIJ-2X/3C 70-120 / NA ESIJ-2X/3C 150-185 / NA ESIJ-2X/3C 240-300 / NA ESIJ-2X/3C 25-50 / SA ESIJ-2X/3C 70-120 / SA ESIJ-2X/3C 150-185 / SA ESIJ-2X/3C 240-300 / SA 25-50 70-120 150-185 240-300 Catalog Number Conductor Size Upto 12KV/Plastic One Conductors (Without Armour) mm² ESIJ-3X/1C 16-25 / NA ESIJ-3X/1C 35-70 / NA ESIJ-3X/1C 95-150 / NA ESIJ-3X/1C 185-300 / NA 16-25 35-70 95-150 185-300 Catalog Number Conductor Size Upto 12KV/Plastic Three Conductors (Without Armour) (With Armour) mm² ESIJ-3X/3C 16-35 / NA ESIJ-3X/3C 50-95 / NA ESIJ-3X/3C 120-185 / NA ESIJ-3X/3C 240-300 / NA ESIJ-3X/3C 16-35 / SA ESIJ-3X/3C 50-95 / SA ESIJ-3X/3C 120-185 / SA ESIJ-3X/3C 240-300 / SA 16-35 50-95 120-185 240-300 Catalog Number Conductor Size Upto 17.5 ,KV/Plastic One Conductor (Without Armour) mm² ESIJ-4X/1C 25-35 / NA ESIJ-4X/1C 50-95 / NA ESIJ-4X/1C 120-185 / NA ESIJ-4X/1C 240-300 / NA 25-35 50-95 120-185 240-300 Catalog Number Conductor Size Upto 17.5KV/Plastic Three Conductors (Without Armour) (With Armour) mm² ESIJ-4X/3C 25-35 / NA ESIJ-4X/3C 50-95 / NA ESIJ-4X/3C 120-185 / NA ESIJ-4X/3C 240-300 / NA ESIJ-4X/3C 25-50 / SA ESIJ-4X/3C 70-120 / SA ESIJ-4X/3C 120-185 / SA ESIJ-4X/3C 240-300 / SA 25-35 50-95 120-185 240-300 Catalog Number Conductor Size Upto 36KV/Plastic One Conductors (Without Armour) mm² ESIJ-6X/1C 35-70 / NA ESIJ-6X/1C 95-150 / NA ESIJ-6X/1C 185-400 / NA ESIJ-6X/1C 500-630 / NA 35-70 95-150 185-400 500-630 Catalog Number Conductor Size Upto 36KV/Plastic Three Conductors (Without Armour) (With Armour) mm² ESIJ-6X/3C 35-70 / SA ESIJ-6X/3C 95-150 / SA ESIJ-6X/3C 185-300 / SA 35-70 95-150 185-300 Single core kits contain material for 1 core only. Ferrules are not included in the kits and should be procured separately. Raychem range of joints include upto 72KV. Please contact ADWAN for CONTROL CABLE JOINTS This range provides heat shrinkable cable joints for multi-core, plastic control cables operating upto 1KV, with armour. Catalog Number Number of Cores Conductor Size mm² ECKJ-0017 ECKJ-0018 ECKJ-0019 ECKJ-0020 ECKJ-0021 4-7 8-14 15-21 22-40 41-75 1.0-2.5 1.0-2.5 For multi-pair cables with and without armour and muti core cables without armour. Please contact ADWAN for details. TRANSITION JOINTS Raychem offers a wide range of heat shrinkable transition joint, upto 36KV, for any of the following configurations: -Cables having a different cross sectional areas. -Plastic to paper cables. -Three core plastic or paper cable to three single core plastic or paper cables. Raychem could also help by designing a transition joint for your specific needs. Please contact ADWAN for details. CABLE JOINTS

Ray Chem

Embed Size (px)

DESCRIPTION

raychem

Citation preview

Page 1: Ray Chem

CABLE TERMINATION & ACCESSORIES א

04

4-21

JOINTS For jointing cables upto 36KV Raychem offers a system based on heat shrinkable materials which is; fast and simple to install, eliminates shelf life limitations, and offers high impact resistance and high earth fault current capacity. Millions of cable joints upto 36KV installed in some of the most severe service condition have confirmed the reliability of Raychem design under high electrical, thermal, and environmental stress.

Catalog Number Conductor Size

Upto 1KV/Plastic Four Conductors (Not Armoured)

List

Price

(Wire Armoured)

mm² ESIJ-OX/4C 1.5-6 / NA ESIJ-OX/4C 6-16 / NA ESIJ-OX/4C 16-35/ NA ESIJ-OX/4C 35-70 / NA ESIJ-OX/4C 70-150 / NA ESIJ-OX/4C 150-300 / NA

76.00 89.00 128.00 237.00 399.00 386.00

ESIJ-OX/4C 1.5-6 / SA ESIJ-OX/4C 6-16 / SA ESIJ-OX/4C 25-50/SA ESIJ-OX/4C70-150/SA ESIJ-OX/4C185-300/SA

1.5-6 6-16

25-50 70-150

185-300

Catalog Number Conductor Size

Upto 7.2 ,KV/Plastic One Conductor

(Without Armour)

mm² ESIJ-2X/1C 25-50 / NA ESIJ-2X/1C 70-120 / NA ESIJ-2X/1C 150-185 / NA ESIJ-2X/1C 240-300 / NA

25-50 70-120

150-185 240-300

Catalog Number Conductor Size

Upto 7.2KV/Plastic Three Conductors (Without Armour)

(With Armour)

mm² ESIJ-2X/3C 25-50 / NA ESIJ-2X/3C 70-120 / NA ESIJ-2X/3C 150-185 / NA ESIJ-2X/3C 240-300 / NA

ESIJ-2X/3C 25-50 / SA ESIJ-2X/3C 70-120 / SA ESIJ-2X/3C 150-185 / SA ESIJ-2X/3C 240-300 / SA

25-50 70-120

150-185 240-300

Catalog Number Conductor Size

Upto 12KV/Plastic One Conductors (Without Armour)

mm²

ESIJ-3X/1C 16-25 / NA ESIJ-3X/1C 35-70 / NA ESIJ-3X/1C 95-150 / NA ESIJ-3X/1C 185-300 / NA

16-25 35-70

95-150 185-300

Catalog Number Conductor Size

Upto 12KV/Plastic Three Conductors (Without Armour)

(With Armour)

mm² ESIJ-3X/3C 16-35 / NA ESIJ-3X/3C 50-95 / NA ESIJ-3X/3C 120-185 / NA ESIJ-3X/3C 240-300 / NA

ESIJ-3X/3C 16-35 / SA ESIJ-3X/3C 50-95 / SA ESIJ-3X/3C 120-185 / SA ESIJ-3X/3C 240-300 / SA

16-35 50-95

120-185 240-300

Catalog Number Conductor Size

Upto 17.5 ,KV/Plastic One Conductor

(Without Armour)

mm² ESIJ-4X/1C 25-35 / NA ESIJ-4X/1C 50-95 / NA ESIJ-4X/1C 120-185 / NA ESIJ-4X/1C 240-300 / NA

25-35 50-95

120-185 240-300

Catalog Number Conductor Size

Upto 17.5KV/Plastic Three Conductors (Without Armour)

(With Armour)

mm² ESIJ-4X/3C 25-35 / NA ESIJ-4X/3C 50-95 / NA ESIJ-4X/3C 120-185 / NA ESIJ-4X/3C 240-300 / NA

ESIJ-4X/3C 25-50 / SA ESIJ-4X/3C 70-120 / SA ESIJ-4X/3C 120-185 / SA ESIJ-4X/3C 240-300 / SA

25-35 50-95

120-185 240-300

Catalog Number Conductor Size

Upto 36KV/Plastic One Conductors (Without Armour)

mm²

ESIJ-6X/1C 35-70 / NA ESIJ-6X/1C 95-150 / NA ESIJ-6X/1C 185-400 / NA ESIJ-6X/1C 500-630 / NA

35-70 95-150

185-400 500-630

Catalog Number Conductor Size

Upto 36KV/Plastic Three Conductors (Without Armour)

(With Armour)

mm²

ESIJ-6X/3C 35-70 / SA ESIJ-6X/3C 95-150 / SA ESIJ-6X/3C 185-300 / SA

35-70 95-150

185-300

Single core kits contain material for 1 core only. Ferrules are not included in the kits and should be procured separately. Raychem range of joints include upto 72KV. Please contact ADWAN for

CONTROL CABLE JOINTS This range provides heat shrinkable cable joints for multi-core, plastic control cables operating upto 1KV, with armour.

Catalog Number

Number of Cores

Conductor Size mm²

ECKJ-0017 ECKJ-0018 ECKJ-0019 ECKJ-0020 ECKJ-0021

4-7 8-14

15-21 22-40 41-75

1.0-2.5 1.0-2.5

For multi-pair cables with and without armour and muti core cables without armour. Please contact ADWAN for details.

TRANSITION JOINTS Raychem offers a wide range of heat shrinkable transition joint, upto 36KV, for any of the following configurations: -Cables having a different cross sectional areas. -Plastic to paper cables. -Three core plastic or paper cable to three single core plastic or paper cables. Raychem could also help by designing a transition joint for your specific needs. Please contact ADWAN for details.

CABLE JOINTS