97
1 2 3 4 5 6 7 8 9 10 11 12 Cost of Other 15-Oct-16 15-Jan-17 Feb 2017 March 2017 2 PURCHASE OF MEDICAL & LAB. EQUIPMENTS A09404 SDA 75,000,000 Single Stage Two Envelope Tender 15-Oct-16 15-Jan-17 Feb 2017 March 2017 For smooth running of hospital 3 PURCHASE OF PLANT & MACHINERY A09601 SDA 33,000,000 Single Stage Two Envelope Tender 15-Oct-16 15-Jan-17 Feb 2017 March 2017 For smooth running of hospital 4 REPAIR & MAINTENANCE OF MEDICAL & LAB EQUIPMENT A13102 SDA 21,000,000 Single Stage Two Envelope Tender 15-Oct-16 15-Jan-17 Feb 2017 March 2017 For smooth running of hospital 5 REPAIR & MAINTENANCE OF PLANT & MACHINERY A13101 SDA 10,500,000 Single Stage Two Envelope Tender 15-Oct-16 15-Jan-17 Feb 2017 March 2017 For smooth running of hospital 6 FURNITURE & FIXTURE A09701 SDA / PLA 4,000,000 Single Stage Two Envelope Tender 15-Oct-16 15-Jan-17 Feb 2017 March 2017 For smooth running of hospital 7 PURCHASE OF IT EQUIPMENTS A9203 SDA 30,000,000 Single Stage Two Envelope Tender 22-Oct-16 22-Jan-17 Feb 2017 March 2017 For smooth running of hospital 8 REPAIR & MAINTENANCE OF IT EQUIPMENTS A13703 SDA 6,400,000 Single Stage Two Envelope Tender 22-Oct-16 22-Jan-17 Feb 2017 March 2017 For smooth running of hospital 9 BOOKS & PERIODICALS A03905 SDA 3,000,000 Single Stage Two Envelope Tender 22-Oct-16 22-Jan-17 Feb 2017 March 2017 For smooth running of hospital 10 SERVICES PEST Control Services A03919 SDA 3,500,000 Single Stage Two Envelope Tender 22-Oct-16 22-Jan-17 Feb 2017 March 2017 For smooth running of hospital RAWALPINDI INSTITUTE OF CARDIOLOGY, RAWAL ROAD, RAWALPINDI 2nd ANNUAL PROCUREMENT PLAN FOR THE YEAR 2016-17 (Under Rule 8 of the Punjab Procurement Rules 2014) Name of the procuring agency: Rawalpindi Institute of Cardiology, Rawalpindi. Sr. # Name of Procurement (Description) Head of Account Alloction Estimated Cost Procurement Procedures / Process Procurement Methods Tentative Date of Procurement Notice Publication Tentative Date of Award of Contract Tentative Delivery Schedule Tentative Date of Completion Benefits Likely to Attain For smooth running of hospital 1 A03942 SDA 46,750,000 Single Stage Two Envelope Tender

RAWALPINDI INSTITUTE OF CARDIOLOGY, RAWAL ROAD, …eproc.punjab.gov.pk/AnnualProcurementPlan/annual... · 5 The Clinical Engineering Handbook 01 2016 6 BMET Study Guide (Preparing

  • Upload
    others

  • View
    3

  • Download
    0

Embed Size (px)

Citation preview

Page 1: RAWALPINDI INSTITUTE OF CARDIOLOGY, RAWAL ROAD, …eproc.punjab.gov.pk/AnnualProcurementPlan/annual... · 5 The Clinical Engineering Handbook 01 2016 6 BMET Study Guide (Preparing

1 2 3 4 5 6 7 8 9 10 11 12

Cost of Other 15-Oct-16 15-Jan-17 Feb 2017 March 2017

2PURCHASE OF MEDICAL & LAB.

EQUIPMENTSA09404 SDA 75,000,000

Single Stage

Two Envelope Tender 15-Oct-16 15-Jan-17 Feb 2017 March 2017

For smooth running

of hospital

3PURCHASE OF PLANT &

MACHINERYA09601 SDA 33,000,000

Single Stage

Two Envelope Tender 15-Oct-16 15-Jan-17 Feb 2017 March 2017

For smooth running

of hospital

4REPAIR & MAINTENANCE OF

MEDICAL & LAB EQUIPMENTA13102 SDA 21,000,000

Single Stage

Two Envelope Tender 15-Oct-16 15-Jan-17 Feb 2017 March 2017

For smooth running

of hospital

5REPAIR & MAINTENANCE OF

PLANT & MACHINERYA13101 SDA 10,500,000

Single Stage

Two Envelope Tender 15-Oct-16 15-Jan-17 Feb 2017 March 2017

For smooth running

of hospital

6 FURNITURE & FIXTURE A09701 SDA /

PLA 4,000,000

Single Stage

Two Envelope Tender 15-Oct-16 15-Jan-17 Feb 2017 March 2017

For smooth running

of hospital

7 PURCHASE OF IT EQUIPMENTS A9203 SDA 30,000,000 Single Stage

Two Envelope Tender 22-Oct-16 22-Jan-17 Feb 2017 March 2017

For smooth running

of hospital

8REPAIR & MAINTENANCE OF IT

EQUIPMENTSA13703 SDA 6,400,000

Single Stage

Two Envelope Tender 22-Oct-16 22-Jan-17 Feb 2017 March 2017

For smooth running

of hospital

9 BOOKS & PERIODICALS A03905 SDA 3,000,000 Single Stage

Two Envelope Tender 22-Oct-16 22-Jan-17 Feb 2017 March 2017

For smooth running

of hospital

10SERVICES

PEST Control ServicesA03919 SDA 3,500,000

Single Stage

Two Envelope Tender 22-Oct-16 22-Jan-17 Feb 2017 March 2017

For smooth running

of hospital

RAWALPINDI INSTITUTE OF CARDIOLOGY, RAWAL ROAD, RAWALPINDI

2nd ANNUAL PROCUREMENT PLAN FOR THE YEAR 2016-17(Under Rule 8 of the Punjab Procurement Rules 2014)

Name of the procuring agency: Rawalpindi Institute of Cardiology, Rawalpindi.

Sr. # Name of Procurement (Description)Head of

AccountAlloction

Estimated

Cost

Procurement

Procedures /

Process

Procurement

Methods

Tentative Date of

Procurement

Notice Publication

Tentative Date of

Award of Contract

Tentative Delivery

Schedule

Tentative Date

of Completion

Benefits Likely to

Attain

For smooth running

of hospital 1 A03942 SDA 46,750,000

Single Stage

Two Envelope Tender

Page 2: RAWALPINDI INSTITUTE OF CARDIOLOGY, RAWAL ROAD, …eproc.punjab.gov.pk/AnnualProcurementPlan/annual... · 5 The Clinical Engineering Handbook 01 2016 6 BMET Study Guide (Preparing
Page 3: RAWALPINDI INSTITUTE OF CARDIOLOGY, RAWAL ROAD, …eproc.punjab.gov.pk/AnnualProcurementPlan/annual... · 5 The Clinical Engineering Handbook 01 2016 6 BMET Study Guide (Preparing

DEMANDS OF BOOKS & PERIODICALS FOR THE YEAR 2016-17

S.# NAME OF BOOKS QTY YEAR

BOOKS OF IT / BIO-MEDICAL

1 Medical Technology for the IT professional (An Essential Guide for

Working Today’s Healthcare setting) 01 2016

2 Medical Equipment Management Manual 01 2016

3 Journal of Clinical Engineering 01 2016

4 Dictionary of health Information Technology and Security (Kindle

Edition) 01 2016

5 The Clinical Engineering Handbook 01 2016

6 BMET Study Guide (Preparing for Certification and Sharpening Your

Skills, 2016 Edition 01 2016

7 HIMSS Dictionary of Healthcare Information Technology Terms,

Acronym and Organization, 01

Latest

Edition

8 Preparing for Success in Healthcare Information and Management System,

The CPHIMS Review Guide. 01

Latest

Edition

BOOKS OF GYNE

1 High Risk Management Option, 6th / 7

th Edition 01 2012

2 Textbook of Prenatal Medicine, 2nd

Edition 01 2006

3 Heart Disease in Pregnancy (Complications & Management) by Akmal –

El - Mazny 01 2014

BOOKS OF NURSING

1 Psychiatric nursing Lippincott William 4th Edition 01 2011

2 Biological & behavioral concept by Thoms Delmar Learning 2003 01 2007

3 Mental Health Nursing & Evidence-Based Introduction 01 2011

BOOKS OF PEADS

1 BNF for Children 2012-13 01 2012

2 Forfar & arneil’s Textbook of Pediatrics with Online Access 7th Edition. 01 2009

3 Medical Emergencies in Children 5th Edition. 01 2012

4 Nelson Textbook of Pediatrics (3 Vol Set) With Online Access 20

th

Edition. 01 -

5 Park’s Pediatric Cardiology for Practitioners 6th Edition. 01 2014

6 Pediatric & Neonatal Mechanical Ventilation With CD 2nd

Edition. 01 2011

7 Rogers’ Handbook of Pediatric Intensive Care 4th Edition. 01 2012

8 The Harriet Lane Handbook 20th Edition. 01 2014

9 Association of Iron Deficiency Anemia With Febrile Seizures Latest

Edition. 01 -

10 Pediatric Cardiology by Robert Anderson Latest Edition. 01 -

11 Comprehensive Surgical Management of Congenital Heart Disease, by

Richard A. Jonas Latest Edition. 01 -

12 Pediatric Cardiac Surgery, Constantine Mavroudis ET AL. 3rd

Edition. 01 -

13 Congenital Cardiac Surgery, Bruce A. Reitz ET. Latest Edition. 01 -

14 Pediatric & Congenital Cardiology, Cardiac Surgery & Intensive Care.

Eduardo M, Da Craz, Ivy, Dunbar, James & Jaggers. 01 2014

15 Nadas Pediatric Cardiology, John F. Keane, James E.Lock, Donald

C.Flyer by Elsevier. 01

Latest

Edition

16 Critical Heart disease in infants & children-Darid G. Nicholas, Ross M

Ungerleider, Philip J. Spevak, William J. Greclay, Duke E Comeron. 01

Latest

Edition

17 Pediatric Cardiology, The Essential Pocket Guide 3rd

Edition, Walter 01 2016

Page 4: RAWALPINDI INSTITUTE OF CARDIOLOGY, RAWAL ROAD, …eproc.punjab.gov.pk/AnnualProcurementPlan/annual... · 5 The Clinical Engineering Handbook 01 2016 6 BMET Study Guide (Preparing

DEMANDS OF BOOKS & PERIODICALS FOR THE YEAR 2016-17

Johnson James Moller Publisher: Willey Blackwell.

18 Manual of Perioperative Care in Adult Cardiac Surgery. Robert M. Bojar,

Willey Blackwell. 01

Latest

Edition

BOOKS OF NUCLEAR CARDIOLOGY

1

Radiation Protection in Medical Imaging and Radiation Oncology (Series

in Medical Physics and Biomedical Engineering) by Richard J. Vetter

(Editor), Magdalena S. Stoeva (Editor) (With CD)

01 2016

2 Nuclear Cardiology, an Issue of Cardiology Clinics By (author) Sharmila

Dorbala , By (author) Piotr Slomka (With CD) 01 2016

3 The Practice of Internal Dosimetry in Nuclear Medicine By (author)

Michael G. Stabin (With CD) 01 2016

4 Radiation Protection in Diagnostic X-Ray ImagingBy (author) Euclid

Seeram , By (author) Patrick C. Brennan (With CD) 01 2016

5 Radioisotope Studies in Cardiology by H J Biersack , by P H Cox (With

CD) 01 2012

6

Nuclear Cardiology Study Guide : A Technologist's Review for Passing

Specialty Certification Exams By (author) Andrzej Moniuszko , By

(author) B. Adrian Kesala (With CD)

01 2015

7 Nuclear Imaging in Clinical Cardiology Edited by M L Simoons , Edited

by Johan H C Reiber (With CD) 01 2014

8 Practical Mathematics In Nuclear Medicine Technology 2

nd Edition,

Patricia Wells, MAE, CNMT (With CD) 01 2014

9 Quick Reference protocol manual for NM Technologist (With CD) 01 2014

10

Nuclear Cardiology: The Basics. (How to maintain a Laboratory) By,

Frans J TH. Wackers MD, PhD, Wendy Bruni, BS, CNMT, Barry L Zaret.

MD(With CD)

01 2014

11 Nuclear and Radiation Physics in Medicine : A Primer By Tony

Key(With CD) 01 2014

12 Atlas of Nuclear Cardiology By (author) Narula Jagat Dilsizian Vasken 01 2014

13 Basic Science of Nuclear Medicine: The Bare Bone Essentials by K H

Lee, PHD (With CD) 01 2015

14 Health Physics, 4th Edition, Herman Camber ((With CD)) 01

Latest

edition

15

Essentials of Nuclear Medicine Physics and Instrumentation By (author)

Rachel A. Powsner , By (author) Matthew R. Palmer , By (author) Edward

R. Powsner (With CD)

01 2013

BOOKS OF ANESTHESIA

1 Anesthesia Secrets Questions You Will Be Asked 4th Ed 01 2013

2 Cardiac Anesthesia Practical Aspects 01 2015

3 Clinical Anesthesia Practice 2nd

Ed 01 2002

4 Duke’s Anesthesia Secrets 5th Ed 01 2016

5 Foundations of Anesthesia Basic Sciences for Clinical Practice With CD-

ROM 2nd

Ed 01 2006

6 Handbook For Stoelting’s Anesthesia & Co-Existing Disease 3rd

Ed 01 2010

7 Handbook of Pediatric Anesthesia 01 2015

8 Handbook of Veterinary Anesthesia 5th Ed 01 2013

9 Manual of Anesthesia For Operation Theater Technicians 01 2013

10 Manual of Local Anesthesia In Dentistry 01 2016

11 Miller’s Anesthesia With Online Access 2 Vols Set 8th Ed 01 2015

Page 5: RAWALPINDI INSTITUTE OF CARDIOLOGY, RAWAL ROAD, …eproc.punjab.gov.pk/AnnualProcurementPlan/annual... · 5 The Clinical Engineering Handbook 01 2016 6 BMET Study Guide (Preparing

DEMANDS OF BOOKS & PERIODICALS FOR THE YEAR 2016-17

12 Miller’s Anesthesia Review 2nd Ed with Online Access 01 2013

13 Obstetric Anesthesia Clinical Anesthesiology Guide 01 2015

14 Shnider and Levinson’s Anesthesia For Obstetrics With Online Access 5

th

Ed 01 2013

15 Stoelting’s Anesthesia & Co-Existing Disease 2nd

South Asia Ed 01 2015

16 The 5-Minute Anesthesia Consult With Online Access 01 2013

17 The Anesthesia Guide 01 2013

18 Understanding Anesthesia Equipment With Online Access 5th Ed 01 2011

BOOKS OF RADIOLOGY

1 The Complete Guide to Cardiac CT. 01 2011

2 Practical Textbook of Cardiac CT & MRI (Tae-Hwanlim) Springer 01 Latest

Addition

3 Cardiac CT Imaging-Diagnosis of Cardiovascular Disease (Mathew J.)

01 Latest

Addition

BOOKS OF PATHOLOGY

1 Manual of Laboratory Medicine by AFIP (Latest Edition) 02 -

2 Robbins Basic Pathology (Latest Edition). 01 -

3 Standards for Blood Bank & Transfusion Services AABB (Latest Edition). 01 -

4 Microbiology by Prescott (Latest Edition). 01 -

5 Bailey & Scoh’s Diagnostic Microbiology (Latest Edition) 01 -

6 Clinical Chemistry by Bishop (Techniques, Principles, Correlation) Latest

Edition 01 -

7 Text Book of Blood Banking and Transfusion Medicine by Sally V.

Rudmann (Latest Edition) 01 -

8 Blood Transfusion in Clinical Medicine by Mollison & Marcela Contreras

(Latest Edition). 01 -

9 Practical Haematology by Dacie & Lewis (Latest Edition). 01 -

10 Lynch’s Medical Laboratory Technology by Stanley S Raphael, Methew J

Lynch (Latest Edition). 01 -

11 Clinical Haematology and Fundamentals of Hemostasis by Denise M

(Latest Edition). 01 -

12 Clinical Laboratory Medicine by Richard Ravel (Latest Edition).

01 -

BOOKS OF PERFUSIONIST / CARDIOPULMONARY BYPASS

1 Cardiopulmonary Bypass (Combridge Clinical Guides). 01 2009

2 System theory. A Modified Extra Corporeal Circuit to Attenuate Systemic

Inflammatory Response Syndrome by Kevin Mccuska PHD CCP). 01 -

3 Cardiac Perfusion and Pumping Engineering Echo by Dhajoo and Ghista. 01 -

4 Extra Corporeal CP Support in Critical Care 4th Ed, by Gail Annich MD. 01 -

5 ECMO Specialist Training Manual 3rd

Ed, (congenital Books). 01 -

6 Comprehensive Surgical Management of Congenital Heart Disease by

Hodder Arnold Publication). 01 -

BOOKS OF PHARMACY

1 Stockley’s Drug Interaction 10th Edition. 01 -

2 A Manual of Adverse Drug Interaction 5th Edition. 01 -

3 Medical Toxicology by Richard 01 -

4 Clinical Pharmacy & Therapeutics by Herfindal. 01 -

5 BNF Peads 01 -

Page 6: RAWALPINDI INSTITUTE OF CARDIOLOGY, RAWAL ROAD, …eproc.punjab.gov.pk/AnnualProcurementPlan/annual... · 5 The Clinical Engineering Handbook 01 2016 6 BMET Study Guide (Preparing

DEMANDS OF BOOKS & PERIODICALS FOR THE YEAR 2016-17

6 Quimp Latest Edtion 02 -

7 Community Pharmacy by Paul Rutter 01 -

8 Adverse Drug Reactions by Lee, Anne, 2nd

Edition. 01 -

BOOKS OF PHYSIOTHERAPY

1 Improving Functional Outcomes in Physical Rehabilitation 1

st Ed by

Susan B. O’Sullivan. 01 -

2 Orthotics and Prosthetics In Rehabilitation, 3e 3

rd Ed by Michelle M.

Lusardi PHD PT. 01 -

3 Geriatric Physical Therapy, 3

rd Ed by Andrew A. Guccione PT and Rita

Wong. 01 -

4 Physical Rehabilitation of the Injured Athlete: Expert Consult – Online

and Print, 4e by James R. Andrews MD and Gary L. Harrelson 01 -

Page 7: RAWALPINDI INSTITUTE OF CARDIOLOGY, RAWAL ROAD, …eproc.punjab.gov.pk/AnnualProcurementPlan/annual... · 5 The Clinical Engineering Handbook 01 2016 6 BMET Study Guide (Preparing

SPECIFICATION OF “COST OF OTHER ITEMS” FOR TENDER 2016-17

S/

No Item Name Qty

Specification/

Description

Estimated cost

A. Instrument For Cardiac Surgery

1 Towel clips blunt 20 As per sample approval

CE, ISO approved

Warranty : 3 year

Approx 6.M (for

local)

(For important US,

Europe, Japan, 15

M approx )

2 Towel clips sharp 20

3 O’ Connor C-19-083 16cm 6 ¼

(Skin hooks)

04

4 Guthrie 16cm 6 ¼ sharp (Skin

hooks)

02

5 Balfour C-19-358 (Abdominal

retector)

01

6 Wire cutter CW-21-1010 01

7 Atrauma cardiovascular klemmen

(cross clamps) C.27-382 20cm/8”

02

8 Atrauma cardiovascular klemmen

(cross clamps) C.27-383 21cm/8

¼”

02

9 De bakey clamps 02

10 Cardiovascular Forceps (Derra

clamps) C-27-439

05

11 Cardiovascular Forceps (Derra

clamps) C-27-454 16cm 6 ¼“

10

12 Cardiovascular Forceps (Derra

clamps) C-27-455 17cm 6 ¾“

10

13 Cardiovascular Forceps (Shunt

clamps) C-27-501

02

14 Cardiovascular Forceps (Shunt

clamps) C-27-502

02

15 Cornery probe 1.0 10

16 Cornery probe 1.5 10

17 Cornery probe 2.0 10

18 Dural 05

19 Debakey tissue forceps 7 inches 20

20 Debakey tissue forceps 9 inches 20

21 Debakey tissue forceps 7 inches

fine

20

22 Langen back large 06

23 Watson chaini 05

24 Free elevator 05

25 Wire twister 10

26 Wire cutter 05

27 Kidney tray 10

28 I.M.A Retector 02

29 Tubing clamps 20

30 Chest retector neonatal 02

31 Cornery suction 10

Page 8: RAWALPINDI INSTITUTE OF CARDIOLOGY, RAWAL ROAD, …eproc.punjab.gov.pk/AnnualProcurementPlan/annual... · 5 The Clinical Engineering Handbook 01 2016 6 BMET Study Guide (Preparing

32 Curved arteries long 20

33 Curved arteries ST 20

34 Nerve hooks fine 10

35 Castro needle holder 8 inches ST 15

36 Castro needle holder 8 inches

curved

15

37 Ring tip forceps 8 inches 10

38 Metzenbaum scissors 8 inches

curved

20

39 ST scissors 8 inches curved 20

40 Mosquito artery forceps 100

41 Rongour 05

42 Bone nebler small 01

43 Bone nebler medium 01

44 Bone cutter 01

45 Cornery scissor forward 45o 10

46 Cornery scissor reverse 60o 10

47 O, Shaugnnesy 5 inches 05

48 O, Shaugnnesy 7 inches 05

49 O, Shaugnnesy 9 inches 05

50 Duct clamps (set of five) 01

51 Deaversretector (set of five) 01

52 Sponge holder 10

53 Arteries curved 7 inches 30

54 Mosqito arteries ST 50

55 Sim forceps 05

56 Potts smith (fine forceps) CA-16-

604

05

57 Waugh (Forceps) C-16-186 18cm 05

58 Tylor forceps C-16-098 05

59 Mixter (Rt angel) C-17-252 22cm 05

60 Baby mixter C-17-246 05

61 Needle holder fine 7 inches 10

62 Needle holder fine 9 inches 10

63 Needle holder fine 8 inches 10

64 Tenotmy scissor 8 inches 20

65 Codwan’s forceps fine 05

66 Seller’s chest spreader 01

67 Pen aortic clamp 05

B. Radiation Protection Devices

1. Liquid for cleaning of lead aprons 30

bottles

Used for cleaning of

lead aprons.

0.2M

2. Ovarian shield 25

As per sample

approval.

Approved any

international

certification. (CE

standard : EU directive

89/686/EU or

0.2M

3. Thyroid collar 15 0.15M

4. Head Cover (Visor) 25 0.25M

5. Apron sleeves 30 0.1M

6. Visors shields 25 0.25M

7. Patient half apron 25 0.5M

8. Breast shield (mammary gland

protective) 25

0.5M

Page 9: RAWALPINDI INSTITUTE OF CARDIOLOGY, RAWAL ROAD, …eproc.punjab.gov.pk/AnnualProcurementPlan/annual... · 5 The Clinical Engineering Handbook 01 2016 6 BMET Study Guide (Preparing

9. Pediatric gonad shield (male) 4 equivalent)

Light weight lead or

equivalent material

Warranty : one year

(start from at the time

of delivery)

As per standard

protection values

0.06M

10. Pediatric mittens (gloves) 4 0.06M

11. Pediatric gonad shield (females) 4 0.06M

12. Lead aprons (adults) 5 0.175M

13. Half Aprons (Cover Gonad

protection)

12

0.18M

C. CSSD

1. ETO kits 36 Used for sterilization

of soft items.

4M

D. Laundry Items

1. De-scalar for Washer drum 600 L Used for Descaling of

washer drums.

0.375M

2. Note: Firm should visit before quoting and take sample before

treatment and after treatment. At the time of services firm qualified

engineer should be there for guideline of chemical dosing.

E. Chemical For Boiler

1. Anti-

corrosion/anti

scale

900 L Used to maintain PH in boiler

and corrosion preventive

(Dynaflok or Equal)

0.56 M

2. De-scalar for

boiler

600 L used to deposit scale

sediment’s from boiler 0.37M

Note: Firm should visit before quoting and take sample before

treatment and after treatment. Also monthly water quality test will be

totally responsibility of the firm.

At the time of annual services firm qualified engineer should be there

for guideline of chemical dosing.

F. Chemicals For HVAC System

1. Chemical for cooling tower regular

dose

170 kg Use for daily cleaning

of cooling tower

0.068M

2. Chemical for cooling tower

descaling

100 kg Use for descaling at the

time of annual services

in cooling tower

0.023M

3. Chemical for close circuit (anti

corrosion anti scale.

1500kg Use for descaling of

close circuit and chiller.

0.75M

4. Chemical for FCUS cleaning 150kg Use for evaporator

cleaning of FCUS

0.067M

Note: Firm should visit before quoting and take sample before

treatment and after treatment. Also monthly water quality test will

betotally responsibility of the firm.

At the time of annual services firm qualified engineer should be there

for guideline of chemical dosing.

Total Estimated coast: RS: 14.898M

Page 10: RAWALPINDI INSTITUTE OF CARDIOLOGY, RAWAL ROAD, …eproc.punjab.gov.pk/AnnualProcurementPlan/annual... · 5 The Clinical Engineering Handbook 01 2016 6 BMET Study Guide (Preparing

Annexure “A”

SPECIFICATION OF “HOSPITAL FURNITURE” FOR TENDER 2016-17

S/N

o Item Required Qty Justification / Purpose

Estimated

coast

1 Crash Cart 10 Used in wards for medicine

and equipment’s 3M

2 Pediatric Patient Trolley

02

Used for mobile purpose of medicine and biomedical equipment in Peads wards.

6M

3 Medicine Trolley 10 Used for mobile of medicine in wards.

1.5M

4

Hydraulic Patient Shifting Trolley With Matters

04 Used for shifting of un concision cardiac patients

0.6M

5 Height Stool / Chair

05 Used for doctors in catch lab (control room).

0.05M

6 Patient Couch 20

Used for cardiac patients when space is not available for beds.

0.6M

Total: 11.75M

Page 11: RAWALPINDI INSTITUTE OF CARDIOLOGY, RAWAL ROAD, …eproc.punjab.gov.pk/AnnualProcurementPlan/annual... · 5 The Clinical Engineering Handbook 01 2016 6 BMET Study Guide (Preparing

Sr. No 01

Clinical specialty Hospital furniture

Generic Name Crash cart

Clinical purpose Used in wards for medicine and equipment’s Quantity 10

Technical specification

The emergency trolley must support different equipment for any type of intervention. Drawer always slide smoothly with double side wall construction. All the accessories are easily attainable to reduce the maneuvers and the

times of intervention.

Accessories

6 drawers unit. Drawer size 3” x 3, 6” x 2 & 9” x 1. Recessed top storage area.

Side shelf.

Accessory panels.

Defibrillator shelf.

4 TENTE Casters 2 lockable.

Breakaway locking bar.

Stabilizing frame with bumper.

Durable aluminum mounting tracks.

Light System.

Stainless Steel I.V. pole.

Double push handle.

1 x Cylinder holder for D or E size cylinder I.

Cardiac board with bracket.

Universal rail system fitted to width of trolley.

Operating manual, Services manual, error code book, part list and

software if any.

Optional: Nil

Warranty

Two year with all spare parts, during warranty period firm should maintain

equipments and done PPM as per principle recommendation. If any spare

part required during installation or PPM will be responsibility of the firm.

Firm must send annual PPM schedule with installation report.

Page 12: RAWALPINDI INSTITUTE OF CARDIOLOGY, RAWAL ROAD, …eproc.punjab.gov.pk/AnnualProcurementPlan/annual... · 5 The Clinical Engineering Handbook 01 2016 6 BMET Study Guide (Preparing

Sr. No 02

Clinical specialty Hospital furniture

Generic Name Pediatric Station Trolley

Clinical purpose Used for mobile purpose of medicine and biomedical

equipment in Peads wards.

Quantity 02

Technical specification

(for use of Pediatric Resuscitation Emergencies)

Drawers are color Coded using the BroselowTMmethod for emergency

pediatric care.

Include:

9 – drawer, A-SMART premier Breakaway Lock Cart with Divider for Small Drawers.

(30” total drawer space).

Tuck-away two-way side shelf, 30” locking bar.(approx.)

Stabilizing frame / bumper system, seamless plastic top, soft grip push handles,

all-swivel TENTE casters (Two locking), and one swivel / fixed tracking caster.

configuration of drawers: 3” (8 No), 6” (1 No) (approx.)

Accessories

1 x Oxygen Tank Bracket.

1 x Suction Unit Holder.

1 x two hook I.V. pole.

Breakaway locking Bar.

Operating manual, Services manual, error code book, part list and

software if any.

Optional

Nil

Warranty

Two year with all spare parts, during warranty period firm should maintain

equipments and done PPM as per principle recommendation. If any spare

part required during installation or PPM will be responsibility of the firm.

Firm must send annual PPM schedule with installation report.

Page 13: RAWALPINDI INSTITUTE OF CARDIOLOGY, RAWAL ROAD, …eproc.punjab.gov.pk/AnnualProcurementPlan/annual... · 5 The Clinical Engineering Handbook 01 2016 6 BMET Study Guide (Preparing

Sr. No 03

Clinical specialty Medical and Lab Equipment

Generic Name Medicine trolley

Clinical purpose Used for mobile of medicine in wards.

Quantity 10

Specification

For the storage and dispensing of medication by ward nursing staff. Frame and carcass shall be constructed from mild steel powder coated/ Polymer. Mounted on approx 125mm castors. The approximate internal dimensions of the medicine container shall be 80 w x50 d x30 h cm. The hinged lid of the unit shall slope down to the front. Lockable with heavy-duty dead lock. Shall be fitted with the following accessories:

o Document support on under lid surface. o 4 tier rack for holding medications. o Waste bins qty 2 off mounted under the medicine container. o Ampoule holding rack. o Dispensing tray to collect spillages when pouring liquid oral medication. o Side mounted fold-down writing flap. o Different compartments for medicines with labeling. o Lower shelf mounted under medicine container.

Unit shall be supplied with a security clamp for wall fixing at the appropriate location, thus ensuring that the trolley is secure when not in use.

Accessories

Operating manual, Services manual, error code book, part list and software

if any.

Optional

Nil

Warranty

Two year with all spare parts, during warranty period firm should maintain

equipments and done PPM as per principle recommendation. If any spare

part required during installation or PPM will be responsibility of the firm.

Firm must send annual PPM schedule with installation report.

Page 14: RAWALPINDI INSTITUTE OF CARDIOLOGY, RAWAL ROAD, …eproc.punjab.gov.pk/AnnualProcurementPlan/annual... · 5 The Clinical Engineering Handbook 01 2016 6 BMET Study Guide (Preparing

Sr. No 04

Clinical specialty Medical and Lab Equipment

Generic Name Hydraulic Patient shifting trolley with matters

Clinical purpose Used for shifting of un concision cardiac patients

Quantity 04

Technical specification

Hydraulic Patient’s trolley for use in patient’s recovery and Emergency area transportation. Upholstered top, with adjustable head full upholstery Side rails Bumper bar/push handle, castors Safe Working Load 180kg Head section adjustable.

Accessories

Matters fine quality medical dedicated and autoclave able.

IV pole

Operating manual, Services manual, error code book, part list and software

if any.

Optional

Nil

Warranty

Two year with all spare parts, during warranty period firm should maintain

equipments and done PPM as per principle recommendation. If any spare

part required during installation or PPM will be responsibility of the firm.

Firm must send annual PPM schedule with installation report.

Page 15: RAWALPINDI INSTITUTE OF CARDIOLOGY, RAWAL ROAD, …eproc.punjab.gov.pk/AnnualProcurementPlan/annual... · 5 The Clinical Engineering Handbook 01 2016 6 BMET Study Guide (Preparing

Sr. No 05

Clinical specialty Medical and Lab Equipment

Generic Name Height stool / chair

Clinical purpose Used for doctors in catch lab (control room)

Quantity 05

Technical specification

Height quality stains less steel with lather cover. As per sample approval.

Accessories

Operating manual, Services manual, error code book, part list and software

if any.

Optional

Nil

Warranty

Two year with all spare parts, during warranty period firm should maintain

equipments and done PPM as per principle recommendation. If any spare

part required during installation or PPM will be responsibility of the firm.

Firm must send annual PPM schedule with installation report.

Page 16: RAWALPINDI INSTITUTE OF CARDIOLOGY, RAWAL ROAD, …eproc.punjab.gov.pk/AnnualProcurementPlan/annual... · 5 The Clinical Engineering Handbook 01 2016 6 BMET Study Guide (Preparing

DEMAND FOR “MEDICAL AND LABORATORY EQUIPMENT” FOR TENDER 2016-17

S/No Equipment Name With Detail Specifications Qty In

Hand

Qty

Required

Estimated

Cost

GYNAE DEPARTMENT

1 Anesthesia Work Station 0 1 6 M

2 OT Table for Gynae Surgery 0 1 2 M

3 TVS Probe USG 0 2 1 M

Operation theatre

4 Head Light 03 02 1 M

5 Cardio Blade Ablation Machine 0 01 5 M

6 Crisis Manikin 0 01 0.8 M

7 Bronchial Tree 0 01 0.3 M

8 Human Skeleton With Nerve System 0 01 0.3 M

9 Microplegia Delivery System Machine 0 01 1 M

10 Cerebral Ox Meter 0 01 1.5 M

11 Endoscopic Vein Harvesting System 0 03 30 M

12 Portable Ultrasound Machine 0 01 1.5 M

13 Live 3-D Echo Machine 0 1 20 M

LABORATORY

14 Water Quality Test Equipment 0 1 0.5 M

15 CO2 Incubator 0 01 0.8 M

16 Refrigerator Centrifuge (Cryofuge) 0 01 4.5 M

17 Plasma Thawing System 0 01 0.7 M

PHYSIOTHERAPY

18 Arm Ergo Meter 0 01 0.12 M

19 Multi Pulley System 0 01 1.5 M

20 Storage Rack With Material 0 01 0.3 M

21 Ultrasound Therapy Unit 0 01 0.5 M

22 Hydrocolator 0 01 0.4 M

23 Recumbent Bike 0 01 1.0 M

24 Telemetry Monitoring System 0 01 5 M

25 Rechargeable / Electric Therapeutic Portable /

handy Ultrasound 0 01 1 M

26 Compression Device 0 01 0.3 M

GENERAL MEDICAL EQUIPMENTS FOR ALL DEPARTMENTS

27 Cardiac Monitors (Vital sign) 186 150 16 M

28 Online Blood Pressure Monitor 0 10 8 M

29 Syringe Pump 174 30 4 M

30 Vain Finder 0 03 1.6 M

31 Pulse Oximeter (Portable) 14 10 1.2 M

32 Blood Warmer / Plasma Therm 05 02 1.5 M

33 Defibrillator (Pacing) 6 06 2.4 M

34 Mobile BP Apparatus 0 10 0.18 M

35 AED 0 04 1.5 M

PAEDS ECHO DEPARTMENT

36 Echocardiography Machine 0 1 4.5 M

Page 17: RAWALPINDI INSTITUTE OF CARDIOLOGY, RAWAL ROAD, …eproc.punjab.gov.pk/AnnualProcurementPlan/annual... · 5 The Clinical Engineering Handbook 01 2016 6 BMET Study Guide (Preparing

HDU-II

37 Dialysis Machine 1 2 2.5 M

CATH LAB

38 Angio Jet and Jet Stream 0 01 14 M

39 Open Irrigation System 0 01 5.5 M

NUCLEAR MEDICINE

40

Contamination Probe for Survey Meter RADOS

RDS-31 Used To Detect Contamination (PNRA

Requirement)

0 1 0.3M

41 Syringe Pump Digital Injector Used For Patients

To Inject Adenosine 0 1 0.2 M

42

Printer For Dose Calibrator (Hot Lab) To Be

Used With VDC-405 Dose Calibrator To Print

The Daily QC Reports

0 1 0.1 M

43

Printer For Spectra Analyzer System, To Be

Used For The Analysis Of Thallium On Weekly

Basis

0 1 0.1 M

44 Dose Calibrator 0 1 0.8 M

45 Co-57 Flood Source 0 1 0.5 M

46 Co-57 point Source 0 1 0.5 M

47 Pocket Dosimeter 0 3 0.1 M

Radiology 48 Work Station for CT 02 01 5 M

49 Portable Ultrasound 0 01 1M

Infection control department

50 Fogging Machine 0 01 6M

Total Estimated Cost: 167.4 M

SPECIFICATION FOR “MEDICAL AND LABORATORY EQUIPMENT” FOR TENDER 2016-17

Sr. No 01

Clinical specialty Medical and lab Equipment

Generic Name Anesthesia Work Station

Quantity 01

Clinical purpose Delivery of anesthesia during Operation.

Technical specification 3 Gas Anesthesia Workstation, 02, N20 and Air Up to 1 x O2 and 1 x N20

Cylinder can be connected Pipelines/fittings/gauges for Central Piping 1 x 02 and 1 x N20 Yokes & Gauges for Cylinders 1 x 02, 1 x N2O and 1 x Air Pipeline, Pipeline Fitting and Pressure Gauges Main Working Surface 1 x Monitoring Shelf 1 x Side Folding Shelf Single 02 High Pressure Outlet 02 Flush Common Gas Outlet Side Rails and Centrally Braked Castors with Large Brake Paddle 2 x Drawers Anesthesia Machine should be capable of working at Low Flow Anesthesia

Page 18: RAWALPINDI INSTITUTE OF CARDIOLOGY, RAWAL ROAD, …eproc.punjab.gov.pk/AnnualProcurementPlan/annual... · 5 The Clinical Engineering Handbook 01 2016 6 BMET Study Guide (Preparing

Scavenging System Venture Suction 1KG Circle/CO2 Absorber, fully Autoclave able, including Bag/Vent switch, CO2 by pass and manometer gauge, complete with mounting bracket, disposable patient circuit, absorber detachable including Y-piece circuit, bag and fresh gas assembly 1 x Bag Arm 2 Station Selecta Tec Back bar to accommodate up to two vaporizers at a time. Electronic / digital flow-meter: Three Gas Configurations (02, N20 and Air) Flow Range: 02 and Air: 0 to 12 LPM N2O: 0 to 12 LPM Total Flow Meter 0 to 10 LPM Calibrated to 02 Thermal Mass Flow Sensor Type Mechanical, Hypoxic Guard for minimum of 25% 02 / Auxiliary Flow Meter Low flow oxygen at 200ml flow meter Anaesthesia Ventilator Microprocessor Controlled Anesthesia Ventilator Full Color Minimum 6 - 8" or more LCD/TFT Touch Screen Display Automatic Leak and Compliance Test Fresh Gas and Compensation Ventilation Modes: Volume Control, Pressure Control. SIMV+PSV, Pressure Support, CPAP, Spontaneous manual Ventilator Monitoring: Oxygen (F102), Inspired & Expired Volumes, Paw, Pressure, Real Time Waveforms for Flow, Volume,& Pressure Tidal Volume: 20 — 1400 ml IE Ratio: 2.0:1 — 1:5 Frequency: 4 — 60 bpm Minute Volume: 0.3 — 25 LPM Pressure Limit: 10 - 70 cmH2O (Adult) & 10-50 cmH2O (Paeds) PEEP: 3 — 20 cmH2O Patient Trigger: 1 — 10 LPM Battery Back Up of 60 minutes Minimum / charging time. User Alarms: High/Low Pressure; High/Low Minute Volume; High/Low Breath Per Minute (BPM); High/Low Oxygen Static Alarms: Apnea, Settings Error, Low Supply Gas, Inspiratory Flow Transducer Error, No Charge, Fresh Gas Too High, Ventilator Inoperative, Under Pressure, Peep Error/Sensor Error, Power Fail, Battery Low, Apnea Alarm in Bag Mode User service manuals with error code book.. Anesthesia agent monitoring

FDA, CE or at least two international standards approved.

Accessories : 1 x Vaporizer, Selecta Tec Type Tec 7 or equivalent, Isoflurane 1 x Vaporizer, Selecta Tec Type Tec 7 or equivalent, Sevoflurane 1 Pin Index Cylinders for 02 1 Pin Index Cylinders for N2O Reuse able/ auto clave able breathing circuit one for adults and one for paeds. All allied accessories.

Page 19: RAWALPINDI INSTITUTE OF CARDIOLOGY, RAWAL ROAD, …eproc.punjab.gov.pk/AnnualProcurementPlan/annual... · 5 The Clinical Engineering Handbook 01 2016 6 BMET Study Guide (Preparing

Operating manual, Services manual, error code book, part list and software if any.

Optional: nil

Warranty: Two year with all spare parts, during warranty period firm should maintain equipments and done PPM as per principle recommendation. If any spare part required during installation or PPM will be responsibility of the firm. Firm must send annual PPM schedule with installation report.

Page 20: RAWALPINDI INSTITUTE OF CARDIOLOGY, RAWAL ROAD, …eproc.punjab.gov.pk/AnnualProcurementPlan/annual... · 5 The Clinical Engineering Handbook 01 2016 6 BMET Study Guide (Preparing

Sr. No 03

Clinical specialty Medical and lab Equipment

Generic Name TVS probe USG

Quantity 02

Clinical purpose Used for diagnostic purpose with Ultra sound

Technical specification:

Compactable with Toshiba nimo MX.

CE/ISO approved

Accessories: nil

Optional: Nil

Warranty :

Two year

Sr. No 02

Clinical specialty Medical and ward Equipment

Generic Name OT table for Gynae

Clinical purpose Used in Gynae OT for surgery

Quantity 01

Technical specification: Hydraulic operation table for Gynae procedure Table Top (Radiolucent) with antistatic mattress 4 section and equipped with X-Ray cassette holder. Table top arranged as Head plate, Back plate, Seat Plate, Two separate leg plates. All control of table movement toward head side X-Ray cassette tunnel full length of table top. Up and down movement height range 810-1250mm Trendelenburg / Anti-trendelenburg + 300, Lateral tilt + 200 Back rest angle adjustment -150/+750 and Leg rest detachable; angle adjustment – 850 / +150 Outward angle 900 Safe working load capacity 170-200Kg FDA, CE or at least two international standards approved.

Accessories: Complete with Anesthetic screen, body rest-holder, shoulder rest-holder, Arm rest-holder, Leg sport, Knee rest-holder, Kidney bolster, Restraining straps, Tray, Foot plate. Operating manual, Services manual, error code book, part list and software if any.

Optional : Nil

Warranty: Two year with all spare parts, during warranty period firm should maintain equipments and done PPM as per principle recommendation. If any spare part required during installation or PPM will be responsibility of the firm. Firm must send annual PPM schedule with installation report.

Page 21: RAWALPINDI INSTITUTE OF CARDIOLOGY, RAWAL ROAD, …eproc.punjab.gov.pk/AnnualProcurementPlan/annual... · 5 The Clinical Engineering Handbook 01 2016 6 BMET Study Guide (Preparing

Sr. No 04

Clinical specialty Medical and lab Equipment

Generic Name Head light

Clinical purpose Used in OT department during surgery.

Quantity 02

Technical specification:

Operating prism loupes to be supplied on a spectacle frame.

The frames to be supplied in three sizes with five available nose bridges to

allow maximum comfort and security for the surgeon. 300/400 Watt

To be easily identifiable by color coding and simple to clip on when needed.

To have a pocket size light source with Brightness Control and a compatible

plug in charger. Complete system with xenon light source

Accessories :

Complete system with xenon light source.

Operating manual, Services manual, error code book, part list and software

if any.

Optional: Nil

Warranty:

Two year with all spare parts, during warranty period firm should maintain

equipments and done PPM as per principle recommendation. If any spare

part required during installation or PPM will be responsibility of the firm.

Firm must send annual PPM schedule with installation report.

Sr. No 05

Clinical specialty Medical and ward Equipment

Generic Name Cardio blade Ablation

Clinical purpose Used in Cardiac OT during surgery

Quantity 01

Technical specification: Argon grade North America Pre-purified Argon≥ 99.998% pure (grade 4.8) Tank pressure 6000psi Tank volume ~ 50 liters Tank diameter 10 inches Tank Height 56 inches

Tank valve fitting CGA77 or CGA680 Cryo time per cylinder

Accessories : Cylinder cap and valve. Operating manual, Services manual, error code book, part list and software if any.

Optional : Nil

Warranty: Two year with all spare parts, during warranty period firm should maintain equipments and done PPM as per principle recommendation. If any spare

Page 22: RAWALPINDI INSTITUTE OF CARDIOLOGY, RAWAL ROAD, …eproc.punjab.gov.pk/AnnualProcurementPlan/annual... · 5 The Clinical Engineering Handbook 01 2016 6 BMET Study Guide (Preparing

part required during installation or PPM will be responsibility of the firm. Firm must send annual PPM schedule with installation report.

Sr. No 06

Clinical specialty Medical and ward Equipment

Generic Name Crisis Manikin

Clinical purpose Used for training purpose of Cardiac Anesthesia

Quantity 01

Technical specification Ambu cardiac care trainer with Manual Monitor and CPR software (ECH Box Built in having 26 ECG Rhythms) and Windows compatible Laptop core i7, Third generation (HP, Dell, Acer) Full body, IV arm and Heart core At least two international standards meet.

Accessories: Operating manual, Services manual, error code book, part list and software if any.

Optional : Nil

Warranty : Two year with all spare parts, during warranty period firm should maintain equipments and done PPM as per principle recommendation. If any spare part required during installation or PPM will be responsibility of the firm. Firm must send annual PPM schedule with installation report.

Sr. No 07 Clinical specialty Medical and Lab Equipment

Generic Name Bronchial tree

Clinical purpose Used for training purpose of Anesthesia department

Quantity 01

Technical specification

As per sample approval

US, Europe, Japan

Accessories

Operating manual, Services manual,

Optional

Nil

Warranty

Two year with all spare parts, during warranty period firm should maintain

equipments and done PPM as per principle recommendation. If any spare

part required during installation or PPM will be responsibility of the firm.

Firm must send annual PPM schedule with installation report.

Sr. No 08

Clinical specialty Medical and Lab Equipment

Generic Name Human skeleton

Clinical purpose Used for training purpose of Anesthesia department

Page 23: RAWALPINDI INSTITUTE OF CARDIOLOGY, RAWAL ROAD, …eproc.punjab.gov.pk/AnnualProcurementPlan/annual... · 5 The Clinical Engineering Handbook 01 2016 6 BMET Study Guide (Preparing

Quantity 01

Technical specification

As per sample approval

US, Europe, Japan

Accessories

Nil

Optional

Nil

Warranty

Two year with all spare parts,

Sr. No 09

Clinical specialty Medical and Lab Equipment

Generic Name Microplegia delivery system machine

Clinical purpose Used for patient during surgery.

Quantity 01

Technical specification

(Microplegia Delivery System Machine)

Microplegia Delivery System Shall be optimal for (Myocardial Protection for Cardiac

Surgery Procedure)

General Feature

System shall feature an intelligent operating modes which consists of:

Pressure Must be Auto-regulated

Temperature Required Warm, Cold, Tepid

Arrest Faction Must Be Control OR set by Systems (As Required)

Flow control Required / Continuous Precise, and Cyclic Delivery of Microplegia.

System Delivery Route / Antegrade, retrograde and simulgrade.

Composition Required / Oxygenated Blood, natural buffers.

Technical Specification for System Flow rate: 10 – 999ml / min.

Accuracy: 1ml / min for 10-100 ml / min.

Resolution: 5 ml / min for 100-999 ml / min.

Air Bubble detection: 100 mul cohesive bubble.

Prime Volume: 190 ml & 45 ml heat exchanger.

Arrest & additive capacity: 50 ml.

Temperature Range: Cold: Ice water controlled.

Temperature Range: Warm: 4-42 Degree Centigrade.

Temperature Accuracy: +- 1 Degree Centigrade.

Blood to Crystalloid Ratio Control: 100% Crystalloid / 100% Blood.

Ration Accuracy: 3% of each component required proportion.

Arrest agent concentration rang: 0 – 40 mEq/L.

Additive concentration rang: 0 – 50 ml/L.

System shall be portable (Easily Moveable).

System shall be fit on HLM (Heart Lungs Machine) if required.

Rated voltage (mains operation) 220 – 240 VAC, 60 – 50 HZ.

Manufacture Requirement Manufacturer should have ISO Certification for Quality Standards.

FDA / CE Approval.

Country of Origin / USA, Europe.

Page 24: RAWALPINDI INSTITUTE OF CARDIOLOGY, RAWAL ROAD, …eproc.punjab.gov.pk/AnnualProcurementPlan/annual... · 5 The Clinical Engineering Handbook 01 2016 6 BMET Study Guide (Preparing

Accessories: Operating manual, Services manual, error code book, part list

and software if any.

Optional

Warranty

Two year with all spare parts, during warranty period firm should maintain

equipments and done PPM as per principle recommendation. If any spare

part required during installation or PPM will be responsibility of the firm.

Firm must send annual PPM schedule with installation report.

Sr. No 10 Clinical specialty Medical and Lab Equipment

Generic Name Cerebral Oximeter

Clinical purpose Used for training purpose of Anesthesia department

Quantity 01

Technical specification:

The device should be FDA cleared for measuring absolute cerebral tissue oxygen latest model. Saturation (Sto2) for all patient population; neonatal (<8kg) and pediatric/adult in their cleared weight and sensor size. Adult sensor with an interrogation depth of 2.5cm. 4 different sensor sizes with 3 different penetration depths in order to Accommodate for the anatomical differences of the different patient population. Compensate for the interference of stool (meconium) when measuring abdominal StO2 in neonates <4kg. Compensate for the effects of melanin and patient specific tissue properties when Measuring cerebral Sto2. Allow for age and weight entry to compensate for anatomical and human growth differences. The device’s data should refresh at every 2 seconds or less. The device should utilize at least 4 laser wavelengths to achieve greater precision and accuracy in Sto2 measurements. The device’s Co-Oximeter Reference value can be obtained from the formula StO2=SaO2 X 0.3 + SjvO2 X 0.7.

Accessories: Operating manual, Services manual, error code book, part list

and software if any.

Optional : Nil

Warranty :

Two year with all spare parts, during warranty period firm should maintain

equipments and done PPM as per principle recommendation. If any spare

part required during installation or PPM will be responsibility of the firm.

Firm must send annual PPM schedule with installation report.

Page 25: RAWALPINDI INSTITUTE OF CARDIOLOGY, RAWAL ROAD, …eproc.punjab.gov.pk/AnnualProcurementPlan/annual... · 5 The Clinical Engineering Handbook 01 2016 6 BMET Study Guide (Preparing

Sr. No 11

Clinical specialty Medical and Lab Equipment

Generic Name Endoscopic vein Harvesting system

Clinical purpose Used for vein harvesting during cardiac surgery.

Quantity 01

Technical specification: Full HD Camera Control Unit CMOS Type Compatible with harvesting device for Cardiac bypass vein and artery harvesting Latest and advanced kit. Full HD Camera system with Latest Chip or Sensor technology for brilliant image display. Full HD image quality (1920 x 1080 pixel provides a crystal clear image) Scan Mode of system should be Progressive Scan 50/60Hz Video Signal Outputs: 2 x DVI - D 1080p (50/60Hz) one for teaching purpose, one for monitor. 2 x HD - SDI 1080i (50/60Hz) one for teaching purpose, one for recording device, 1 x S - Video PAL for printer.

Camera Head with Zoom coupler. Camera Resolution: 1920x1080 Pixel Buttons on Camera Head: at least 4 button with 5 Functions or more. Optical Zoom:2x or more Digital zoom: 2.5x or better Length Camera Cable 4 meter minimum

Harvesting Tool: Should consist with following parts for better activity. Harvesting Cannula Tool Adapter Port C-Ring Slider Hemo pro Harvesting Tool place. Hemo pro Jaws tool space. C-Ring must be part of it. Harvesting Tool Extension Cable Connector Scope Washer Connector (blue) Distal Insufflations Connector Activation Toggle for bisector. Harvester Endoscope: 7mm extended length Telescope with Dissection Tip or more.

It should have built tip nose for Target focus on vein. Should be 0 Degree Straight forward.

Endoscopic Harvester Power Generator: DC Type. It should have Extension Cable Connector with Power Cord Connector and low Power Setting Knob with LED Power-On Indicator and Hanger. Cutting tool should not have thermal expansion for the better quality of Vein or artery. System should not have any bipolar cutting instrument or equipment along with to avoid Thermal expansion.

System must be equipped with Harvester Extension cable and Harvester Adapter LED Light Source:- Xenon 300 watt or more / LED. Life span 500 hours on continuous use

Page 26: RAWALPINDI INSTITUTE OF CARDIOLOGY, RAWAL ROAD, …eproc.punjab.gov.pk/AnnualProcurementPlan/annual... · 5 The Clinical Engineering Handbook 01 2016 6 BMET Study Guide (Preparing

Colour temperature : 6000 K Light Guide Cable :1 pcs. light intensity should be continuously adjustable

HIGH FLOW INSUFFLATOR:- Maximum Gas Flow 20 L / min or more. With Pressure Range 5 - 25 mm Hg Fully automatic insufflators, High pressure tube 1m. Reusable silicon tube and Insufflations balloon with trocar.

System should be closed tunnel for the maximum safety of patient and better affectivity.

Ultra-High Definition Medical Monitor 26'' with Bright LED Backlight :- Panel Quality Active Matrix TFT Brightness (cd/m2) 800 Resolution Pixel 1920 * 1080 (Full HD) or better Viewing Angle 1780 / 1780, Aspect Ratio 16:9 Classification acc. To directive 93/42/EEC : I

Video Signal Inputs: 2 * DVI (DVI - D & DVI - I), 2 * SDI / HD – SDI (BNC), S – Video (DIN – 4 or 2 * BNC)

System should be FDA and CE with full safety and features. Country of Origin: UK, USA and Western Europe.

Accessories :

Disposable Kit Harvester: 25 X quantity Included: Harvester Cannula with Traction device, Harvesting Bisector (Three in one Cutting, coagulation, and dissection), Trocar Cannulae, syringe. Disposable kit should have clinical studies more than 100,000 patients for better outcomes and trust on therapy. Video Endoscopic Cart, Imported from same manufacturer. Operating manual, Services manual, error code book, part list and software if any.

Optional : Nil

Warranty :

Two year with all spare parts, during warranty period firm should maintain

equipments and done PPM as per principle recommendation. If any spare

part required during installation or PPM will be responsibility of the firm.

Firm must send annual PPM schedule with installation report.

Sr. No 12

Clinical specialty Medical and Lab Equipment

Generic Name Portable ultra sound machine

Clinical purpose Used for ultra sound in different departments.

Quantity 01

Technical specification

A complete dedicated high end digital Color Doppler Ultrasound unit for wide range of premium performance application of Abdominal, OBS/GYN, Urology, and vascular imaging in pediatrics and adult. Mobile Portable system with built in workstation / data management system for digital acquisition, storage and review of complete ultrasound

Page 27: RAWALPINDI INSTITUTE OF CARDIOLOGY, RAWAL ROAD, …eproc.punjab.gov.pk/AnnualProcurementPlan/annual... · 5 The Clinical Engineering Handbook 01 2016 6 BMET Study Guide (Preparing

studies including static and dynamic clips in DICOM format, read/write zoom. Studies can be reviewed and output to CD / DVD/USB. System Should have built-in battery. The machine must have sharp and high quality image reproduction with heavy duty performance. It should have minimum following specification : DISPLAY: High resolution non interlaced, flicker free 15” LCD/TFT display tilt able. OPERATING MODES: B, 2D M-Mode, Power Doppler, HPRF, Spectral Doppler, Color Doppler, Pw Doppler, Duplex And Triplex Doppler, IMT imaging, Contrast Imaging, Panoramic Imaging, Compound Imaging, 3D/4D imaging. CONTROL PANEL: Alphanumeric keyboard with built-in trackball. Direct access to system functions through dedicated keys. Indicator lights identify activated keys. Audio volume control with bidirectional / stereo speakers and foot switch. User selectable image magnification control. Adjustable transmit focusing control. Total and Lateral Gain Compensation controls (6 or more). 2 Active Probe connectors CALIPER / MEASUREMENTS : 4 to 8 calipers for measurement per screen trace length measurements for: Distance, angle, distance depth from skin line, area, circumferences, compound / volume, OBS/GYN measurements, Urological measurements, Vascular Measurements with IMT. APPLICATION: Abdominal, OBS/GYN, Urology, vascular, Small Parts, Peripheral for pediatric, adult with all required software for measurements. DISPLAY MODES: Live and stored display format: full size and split screen. Review image format: for still and cine, simultaneous capability B+PW, B+ CFM +PW, B+ or triplex mode, B+ color split screen display. 2D mode, , M-mode, color Doppler imaging, color Doppler imaging, color m-mode, PW / HPRF Doppler, IMT, Panoramic Imaging, Vascular imaging , vascular calculations. CINE MEMORY Min. Cine Memory for 8000 frames or 250mb min. IMAGE VIEWING DEPTH: 30 – 300 mm or more for cardiac application IMAGING MODES / TECHNIQUES: Tissue harmonic Imaging, Power Doppler Imaging, Vascular imaging software for carotids STORAGE DEVICE Built-in CD / DVD/ USB Drive SYSTEM DYNAMIC RANGE Dynamic range minimum 200 dB or more COMMUNICATION SOFTWARE System should upgradable for DICOM 3 communication software for: Image Storage, print, Query / Retrieve, Network Communication. PORTS: Video Output, USB / RS 232, Networking POWER REQUIREMENT 220-240VAC 50 Hz Battery Back up 3-4 hour built in battery backup. FDA (510 k) and CE approved.

Accessories:

Multi frequency Convex Probe to cover 2.5 -6.0MHz.

Page 28: RAWALPINDI INSTITUTE OF CARDIOLOGY, RAWAL ROAD, …eproc.punjab.gov.pk/AnnualProcurementPlan/annual... · 5 The Clinical Engineering Handbook 01 2016 6 BMET Study Guide (Preparing

Multi frequency Linear Probe to cover 7.5-12.0 MHz.

Imported Trolley

Thermal Printer 256-Gray scale

50 High Density / High Glossy thermal paper Rolls

Gel: 20 liters

Operating manual, Services manual, error code book, part list and software

if any.

Optional: Multi frequency Transvaginal Probe to cover 5 -7.0MHz

Warranty :

Two year with all spare parts, during warranty period firm should maintain

equipments and done PPM as per principle recommendation. If any spare

part required during installation or PPM will be responsibility of the firm.

Firm must send annual PPM schedule with installation report.

Sr. No 13

Clinical specialty Medical and Lab Equipment

Generic Name 3-D echo machine

Clinical purpose Used for live 3-D echo cardiograph

Quantity 01

TECHNICAL SPECIFICATION: At latest version Digital Echocardiography Unit for the clinical routine and research and cardiovascular applications. All vendors should quote the top of the line latest system. System should have capability for high processing to achieve high frame rate up to 2500 are better. System Channels at least 5,500,000 channels. verified by OEM printed TDS System frequency range 2-20 MHz 21” or more flat panel flicker free monitor LCD. Tilt and swivel stand for LCD Monitor. 12” or more touch screen control panels. PW Doppler with independent HPRF. Image memory kit (4000 frames or more). Automatic adjustment of B-gain and TGC with one touch button for image optimization I Scan. Keyboard with built in trackball and mouse. Up to 2700 fps in 2D should be verified in the technical brochure of the equipment. Dual focus.

Contrast imaging using high or low MI (Mechanical Index). Optional Contrast pulse sequencing technology (real time low mechanical index for contrast agent examinations, Soft ware should have capability to show contrast agent only, tissue only or contrast and tissue only. Optional Contrast harmonic imaging capability. Scanning Option:

Electronic Convex.

Electronic Sector.

Electronic Linear with independent PV steering. B mode specification:

Page 29: RAWALPINDI INSTITUTE OF CARDIOLOGY, RAWAL ROAD, …eproc.punjab.gov.pk/AnnualProcurementPlan/annual... · 5 The Clinical Engineering Handbook 01 2016 6 BMET Study Guide (Preparing

Viewing Depth: 2-30 cm.

Display Size: up to 10 x more with PAN / Zoom. M. Mode Specification:

Scrolling with 4 speeds. D Mode Specifications: PWD, HPRF and CWD Doppler employing FET with window function contrast control and base shift facilities, auto PRF facility. Color Doppler Specifications: CWD and PWD Doppler are continuously steerable in the color blood flow image in real time. Tissue Velocity. Complete Cardiac Calculation in 2D and 3D imaging. Cine Memory 2200 frames. An integrated patient data management workstation with DCD/CD writer. All required software in standard. Tissue Harmonic imaging for cardiac and vascular imaging. Display mode:

B/M Scan Mode. o B single / dual. o B/M. o M.

Doppler Mode. o B. o B/M/D. o B/D. o M/D. o D.

Color Doppler Mode. Tissue Doppler Imaging. Edge Assisted Ejection Fraction for assisted boundary detection technique. Integrated multi stage stress echo system for advanced and flexible stress echo Examinations. Communication software Dicom 3.0 complete image storage, point, queries retrieved, network communication. 2D Spectral Tracking. Probes Phased array sector probe for adults cover 2-3.5 MHz Phased array Sector Probe for pediatrics to cover 3.5-7 MHz or better. Live 3D/4D probe electronic switchable for adult – that can be used for routine 2D/B mode as well

Optional Probe

Live 3D/4D probe electronic switchable for peads – that can be used for routine 2D/B mode as well

3D/4D acquisition rate to be at least 400 mega voxel/sec

Multiplan TEE Probe (3.5-7 MHz or better) matrix quality for 3D (4D) imaging for Adult and Peads echocardiography cases in mandatory.

3-D (4D) imaging software with complete on-cart and off-cart volumetric quantification package including 2 Dimensional Quantification-Region of interest, intimate media Thickness, Strain, Border, Detection, Parametric Quantification, semi-automated border detection for cardiac chambers and vessel cavities, LV systolic / diastolic functions including fraction area change, peak ejection change, 3 dimensional quantification for distance

Page 30: RAWALPINDI INSTITUTE OF CARDIOLOGY, RAWAL ROAD, …eproc.punjab.gov.pk/AnnualProcurementPlan/annual... · 5 The Clinical Engineering Handbook 01 2016 6 BMET Study Guide (Preparing

measurement, left ventricle volume, Mass Ejection / Fraction and MPR. LV Segment based global volume wave form and 3 DCRT Evaluation. 3-D/4D Acquisition with minimum 400 mega voxels per second. Should be verified by technical/sales brochure

International Standard Must be approved: CE Marked (MDD) 93/42/EEC. FDA 510K.

Future Upgrades: Capability for Future up gradation.

Accessories: Operating manual, Services manual, error code book, part list and software if any.

Warranty: Two year with all spare parts, during warranty period firm should maintain equipments and done PPM as per principle recommendation. If any spare part required during installation or PPM will be responsibility of the firm. Firm must send annual PPM schedule with installation report.

Sr. No 14

Clinical specialty Medical and Lab Equipment

Generic Name Water quality Test equipment

Clinical purpose Used to check quality of water in laboratory.

Quantity 01

Technical specification

CE marked .

Capable to test microbiology of water.

Take minimum time for test.

Accessories:

Operating manual, Services manual, error code book, part list and software

if any.

Optional : Nil

Warranty :

Two year with all spare parts, during warranty period firm should maintain

equipments and done PPM as per principle recommendation. If any spare

part required during installation or PPM will be responsibility of the firm.

Firm must send annual PPM schedule with installation report.

Sr. No 15

Clinical specialty Medical and Lab Equipment

Generic Name CO2 Incubator

Clinical purpose Used in microbiology for microorganism growth.

Quantity 01

Technical specification:

Temperature Range: Up to 60 ºC

Control Accuracy: ± 0.5ºC

Page 31: RAWALPINDI INSTITUTE OF CARDIOLOGY, RAWAL ROAD, …eproc.punjab.gov.pk/AnnualProcurementPlan/annual... · 5 The Clinical Engineering Handbook 01 2016 6 BMET Study Guide (Preparing

Volume: 50-80 litters

Display: LED

Operating Voltage: 220 Volts

Humidity Range (% RH): 90-95

CO2 Range:0-20%

Auto-sterilization with hot air at 180 °C

Humidification system with condensation protection

CO₂ gas-mixing jet with Venture effect

Builtin CO₂ sensor and measuring technology

Tightly sealed inner door made of tempered safety glass

Seamless, deep-drawn inner stainless steel chamber

Perforated shelves, stainless steel

Tempered glass inner door

with audible and visual alarm

Over temperature monitor

Easy-to-clean interior,

Reinforced by deep drawn ribbing with integrated and protected

large-area heating on four sides

ISO/FDA/CE marked

Accessories: Operating manual, Services manual, error code book, part list

and software if any.

Optional : Nil

Warranty :

Two year with all spare parts, during warranty period firm should maintain

equipments and done PPM as per principle recommendation. If any spare

part required during installation or PPM will be responsibility of the firm.

Firm must send annual PPM schedule with installation report.

Sr. No 16

Clinical specialty Medical and Lab Equipment

Generic Name Refrigerator Centrifuge (Cryofuge)

Clinical purpose Used for the preparation of blood components (FFP,

platelets )

Quantity 01

Technical specification:

Max Capacity: 6 x 1000 ML bottle

12 quin or quad blood bags

Max RCF (*g): 5735 to 7,500

Max Speed (rpm): 3500 to 5, 00

Speed Range (rpm/g): 500 to 4900 rpm/ 80 to 7300 * g

Acceleration Rates: 08-12

Deceleration Rates: 08-12

Temperature Range: -8°C to +40°C

Control System: Microprocessor control, self diagnostics for servicing

Display: VIDEO set graphics (includes run graph), Info/Error messages

Page 32: RAWALPINDI INSTITUTE OF CARDIOLOGY, RAWAL ROAD, …eproc.punjab.gov.pk/AnnualProcurementPlan/annual... · 5 The Clinical Engineering Handbook 01 2016 6 BMET Study Guide (Preparing

in two languages

Motor: High-performance Induction (brushless)

Max Power: 4500 VA

ISO/FDA/CE marked

Accessories: Operating manual, Services manual, error code book, part list

and software if any.

Optional : Nil

Warranty :

Two year with all spare parts, during warranty period firm should maintain

equipments and done PPM as per principle recommendation. If any spare

part required during installation or PPM will be responsibility of the firm.

Firm must send annual PPM schedule with installation report.

Sr. No 17

Clinical specialty Medical and Lab Equipment

Generic Name Plasma Thawing System:

Clinical purpose Used for thawing of FFP.

Quantity 01

Technical specification

Thaw Capacity: 06-08 Bags Thaw time: Short thaw time 06-10 Minutes Chamber Material: Stainless Steel Specialized basket-unit for swing Basket for easily loading Basket Material: Stainless Steel With over-temperature alarming system to protect FFP Digital temperature monitor Microprocessor temperature controller with audible and visual high temperature alarm Overwrap Protection Large opening for easy cleaning.

ISO/FDA/CE marked

Accessories:

Operating manual, Services manual, error code book, part list and software

if any.

Optional: Nil

Warranty:

Two year with all spare parts, during warranty period firm should maintain

equipments and done PPM as per principle recommendation. If any spare

part required during installation or PPM will be responsibility of the firm.

Firm must send annual PPM schedule with installation report.

Sr. No 18

Clinical specialty Medical and Lab Equipment

Generic Name Arm Ergometer

Page 33: RAWALPINDI INSTITUTE OF CARDIOLOGY, RAWAL ROAD, …eproc.punjab.gov.pk/AnnualProcurementPlan/annual... · 5 The Clinical Engineering Handbook 01 2016 6 BMET Study Guide (Preparing

Clinical purpose Used for upper limbs exercise

Quantity 01

Technical specification

Approved and authorized for medical use Arm ergometer ideal for Physiotherapy and cardio vascular rehabilitation User interface must be user friendly Speed self-generating High level of safety Resistance: Isokinetic (speed control): 15 speed settings (increments of 5 deg/sec) or more Work Rate Range: Up to 600 watts (120 rpm) or more Speed Control Range: 50 to 120 deg/sec or more adjustable Readouts: Time, RPM, watts, calories, METs, heart rate, total work, total cycles ormore. Telemetry compatible

Accessories

Complete with standard accessories. Operating manual, Services manual, error code book, part list and software if any.

Optional

Nil

Warranty

Two year with all spare parts, during warranty period firm should maintain

equipments and done PPM as per principle recommendation. If any spare

part required during installation or PPM will be responsibility of the firm.

Firm must send annual PPM schedule with installation report.

Sr. No 19

Clinical specialty Medical and Lab Equipment

Generic Name Multi pulley system

Clinical purpose General/ multipurpose body exercise

Quantity 01

Technical specification

Approved and authorized for medical use. Automated and computerized adjustment of weight. High level of safety and adjust able seat height. Pre-stretched nylon coated steel cables,wear free, 4 inch pulleys (or more )withquality ball bearings. 200 lbs plastic weight (adjustable) stack, Steel safety shrouds around the weight stack or more. Offers over 25 (at least) or more upper and lower body exercises. Dimension 1660mm (L) x 1160mm (W) x 2020mm (H) with in or near about theses limits. Back rest must be comfortable and provides good support. AB strap station, curl/row bar, lat bar and adjustable velcro ankle strap for leg workouts or more.

Accessories

Operating manual, Services manual, error code book, part list and software

Page 34: RAWALPINDI INSTITUTE OF CARDIOLOGY, RAWAL ROAD, …eproc.punjab.gov.pk/AnnualProcurementPlan/annual... · 5 The Clinical Engineering Handbook 01 2016 6 BMET Study Guide (Preparing

if any.

Optional

Nil

Warranty

Two year with all spare parts, during warranty period firm should maintain

equipments and done PPM as per principle recommendation. If any spare

part required during installation or PPM will be responsibility of the firm.

Firm must send annual PPM schedule with installation report.

Sr. No 20

Clinical specialty Medical and Lab Equipment

Generic Name Storage rack with material

Clinical purpose Used for frozen shoulder and basic weight training.

Quantity 01

Technical specification

Storage rack of wooden Wooden block of 10*6*4 and 20*10*5 (03*each) Club original Exercise stick of wooden 100cm (*6) Medicine ball leather (1.5kg, 2kg, and 3kg)

Accessories

Operating manual, Services manual, error code book, part list and software

if any.

Optional

Nil

Warranty

Two year with all spare parts, during warranty period firm should maintain

equipments and done PPM as per principle recommendation. If any spare

part required during installation or PPM will be responsibility of the firm.

Firm must send annual PPM schedule with installation report.

Sr. No 21

Clinical specialty Medical and Lab Equipment

Generic Name Ultrasound Therapy unit

Clinical purpose Used for pain management at physiotherapy

department

Quantity 01

Technical specification

Ultrasound, Frequencies 1 and 3 MHz Continuous and Pulse Frequency / Duty Cycle 100 Hz / 5, 10, 20, 50% or more. Multi-Frequency Treatment head 1 and 3 MHz Large Contact Control Automatic Power Switch-off and treatment time Interruption in case of insufficient contact

Page 35: RAWALPINDI INSTITUTE OF CARDIOLOGY, RAWAL ROAD, …eproc.punjab.gov.pk/AnnualProcurementPlan/annual... · 5 The Clinical Engineering Handbook 01 2016 6 BMET Study Guide (Preparing

The visual indicator of the treatment head switches on when in proper contact Number of connections : 1 or more Intensity : 0-2 W/com2 continuous, 0-3 W/cm2 pulsed Programmable memory Mains voltage: 100-240 V + 10% (50/60 Hz) or other Anatomical based treatment modes. Dimensions: 290x280x105 mm or more Complete with standard accessories

Accessories

Operating manual, Services manual, error code book, part list and software

if any.

Optional

Nil

Warranty

Two year with all spare parts, during warranty period firm should maintain

equipments and done PPM as per principle recommendation. If any spare

part required during installation or PPM will be responsibility of the firm.

Firm must send annual PPM schedule with installation report.

Sr. No 22

Clinical specialty Medical and Lab Equipment

Generic Name Hydrocolator

Clinical purpose Used for pain and spasm management at

physiotherapy department.

Quantity 01

Technical specification

Approved and authorized for medical used with slandered 12 moist pack Pack of 25 x30 cm. Easley moved on rubber wheels Tank capacity: 69 litter Temperature range: 71- 74 c or more Power : 220-240v, 50/60 hz, 1000 w

Accessories

Standard accessories.

Operating manual, Services manual, error code book, part list and software

if any.

Optional

Nil

Warranty

Two year with all spare parts, during warranty period firm should maintain

equipments and done PPM as per principle recommendation. If any spare

part required during installation or PPM will be responsibility of the firm.

Firm must send annual PPM schedule with installation report.

Page 36: RAWALPINDI INSTITUTE OF CARDIOLOGY, RAWAL ROAD, …eproc.punjab.gov.pk/AnnualProcurementPlan/annual... · 5 The Clinical Engineering Handbook 01 2016 6 BMET Study Guide (Preparing

Sr. No 23

Clinical specialty Medical and Lab Equipment

Generic Name Recumbent bike

Clinical purpose Used in exercise for DCM patients.

Quantity 01

Technical specification

Approved and authorized for medical used. Bicycle ideal for physiotherapy and cardio vascular rehabilitation User interference must be user friendly multiple level of resistance Speed self-generating adjustable seat arm support and back support Compatible with telemetry Smooth and noise free High level of safety Complete with stranded

Accessories

Operating manual, Services manual, error code book, part list and software

if any.

Optional

Nil

Warranty

Two year with all spare parts, during warranty period firm should maintain

equipments and done PPM as per principle recommendation. If any spare

part required during installation or PPM will be responsibility of the firm.

Firm must send annual PPM schedule with installation report.

Sr. No 24

Clinical specialty Medical and Lab Equipment

Generic Name Telemetry Monitoring System

Clinical purpose Monitoring system used during cardiac rehabilitation

Exercise.

Quantity 01

Technical specification

8 patients telemetry monitoring system upgrade able upto 32 patients Dedicated for cardiac rehabilitation 12 lead ECG, HR, spo2, NIBP and temperature PR or more PC based system architecture with windows operating system.

Pre-configured branded PC hardware from manufacturer/system with LCD.

Accessories

Operating manual, Services manual, error code book, part list and software

if any.

Optional

Nil

Warranty

Two year with all spare parts, during warranty period firm should maintain

Page 37: RAWALPINDI INSTITUTE OF CARDIOLOGY, RAWAL ROAD, …eproc.punjab.gov.pk/AnnualProcurementPlan/annual... · 5 The Clinical Engineering Handbook 01 2016 6 BMET Study Guide (Preparing

equipments and done PPM as per principle recommendation. If any spare

part required during installation or PPM will be responsibility of the firm.

Firm must send annual PPM schedule with installation report.

Sr. No 25

Clinical specialty Medical and Lab Equipment

Generic Name Rechargeable / Electric Therapeutic Portable / handy Ultrasound

Clinical purpose Used for pain management for different wards

(mobile purpose).

Quantity 01

Technical specification

1 MHz Ultrasound with Pulsed and Continuous Output

Rechargeable ultrasound either in a docking station or via a mains adaptor or USB

cable to your computer

High quality therapeutic ultrasound delivers the same output as used by

physiotherapists and healthcare professional in sports therapy

Very simple and easy to use

Top quality polished stainless steel transducer head delivers exceptional smooth

ultrasound transmissions for the best results in ultrasound therapy treatments.

30 Treatments from one single charge

Relive Pain

Helps reduce inflammation fast

Ideal for reducing scar tissue

Sports injuries - Neck & shoulder pains, ankle injuries, groin injuries hamstring

strains and much more

Sciatica pain, arthritis pains and joint pain

Cellulite reduction

Rechargeable

Comes Complete with: 1 x Ultrasound unit ,1 x Charging Station, 1 x Mains adaptor ,1 x Ultrasound Manual /

User Guide,1 x 250ml Ultrasound Gel, 1 x Professional Hard Carry Case ,Therapeutic

ultrasound in pulses at 3 power settings (low, med & high), Targeted pain relief .

Speed healing - ultrasound is used by physiotherapist in physical therapy to treat pain,

spasms & inflammation. Ultrasound promotes tissue heating & blood flow to speed

the recovery process & injury rehab.

Convenient & easy

FDA & CE Mark approved.

Accessories

Operating manual, Services manual, error code book, part list and software

if any.

Optional

Nil

Warranty

Two year with all spare parts, during warranty period firm should maintain

equipments and done PPM as per principle recommendation. If any spare

part required during installation or PPM will be responsibility of the firm.

Page 38: RAWALPINDI INSTITUTE OF CARDIOLOGY, RAWAL ROAD, …eproc.punjab.gov.pk/AnnualProcurementPlan/annual... · 5 The Clinical Engineering Handbook 01 2016 6 BMET Study Guide (Preparing

Firm must send annual PPM schedule with installation report.

Sr. No 26

Clinical specialty Medical and Lab Equipment

Generic Name Pneumatic compression device

Clinical purpose Used for preferable edema and bed riddle patients

in physiotherapy department

Quantity 01

Technical specification

Delivers compression to leg or foot, or both simultaneously.

Clinically-proven, sequential, circumferential, gradient leg compression.

LCD Display

Inclusive Power Indicator displays power source.

One Touch Operation

Port A& B indicator.

Audio and visual alarms, e.g. Low battery, single port use etc.

Voltage: 220 VAC

A flexible and transportable design lets you decide when to plug in for therapy or to take advantage of battery-powered freedom. Battery Backup

Easy to transport with a small footprint and light- weight

Ergonomic handle and integrated versatile bed mount.

Compression Parameters

Sequential, Gradient, Circumferential

Vascular Refill Detection

Automatic pressure adjustment

Compact & Portable, patient bed hanging system.

Accessories

SCD Sleeve Thigh Length Small INT, SCD Sleeve Thigh Length Medium INT

SCD Sleeve Thigh Length Large INT, SCD Tubing Set, SCD Sleeve Knee Length Medium INT SCD Sleeve Knee Extra Large, SCD Foot Cuffreg INT

Operating manual, Services manual, error code book, part list and software if any.

Optional

Nil

Warranty

Two year with all spare parts, during warranty period firm should maintain

equipments and done PPM as per principle recommendation. If any spare

part required during installation or PPM will be responsibility of the firm.

Firm must send annual PPM schedule with installation report.

Page 39: RAWALPINDI INSTITUTE OF CARDIOLOGY, RAWAL ROAD, …eproc.punjab.gov.pk/AnnualProcurementPlan/annual... · 5 The Clinical Engineering Handbook 01 2016 6 BMET Study Guide (Preparing

Gen ward, CCU, HDU

Sr. No 27

Clinical specialty Medical and Lab Equipment

Generic Name Cardiac monitors(Vital sign monitor)

Clinical purpose Used to check vital signs of the patients.

Quantity 150

Technical specification

For monitoring of patients vital signs Operating Features and Characteristics:

Non fade TFT color display

Electro-surgical interference suppression/protection

Defibrillator protection

Freeze and cascade facility

Waveform trace speed: 25 to 50 mm/sec

Screen Size: min. 10” or more TFT/LCD color Touch Screen display PARAMETERS: ECG:

Numeric: heart rate

Waveform: 12 Wave forms minimum, real time and freeze

ECG trace Non-Invasive Blood Pressure (NIBP):

Method: Oscillometric principle

Numeric: Systolic, diastolic and mean pressures

Selectable auto inflate interval settings

Rising cuff / continuous pressure display Temperature:

Numeric: Temperature selectable in oC / oF

Channels: 2 channels Pulse Oximetry:

Numeric: 0-100% oxygen saturation measuring range.

Waveform: plethysmograph pulse with pulse strength indication.

Reusable sensor electrode.

Reusable cuff. Arrhythmia Analysis:

Arrhythmia analysis and st analysis.

Minimum 10 arrhythmia items. Respiration:

Breath rate display and alarms.

Sweep speed; 12.5 to 50 mm/sec. Other Features:

Trend Data; up to 72 hours trend graphical and tabular Alarms:

High & low (settable) on all parameters

Visual and audible indication of alarms.

Page 40: RAWALPINDI INSTITUTE OF CARDIOLOGY, RAWAL ROAD, …eproc.punjab.gov.pk/AnnualProcurementPlan/annual... · 5 The Clinical Engineering Handbook 01 2016 6 BMET Study Guide (Preparing

Operating Requirements:

Ac 22ov/50hz

Built-in rechargeable battery for at least 1-2 hours AC power failure at full

parameter

Wall Mount (Original / Local)

Capability of central monitoring system. CE, FDA, JIS or at least two international standards approved.

Accessories

Note-1: The system must be complete with all sensors, probes, cables or any other accessories required for measuring all the above selected parameters. Monitor should be compatible with central monitoring system. Note-2: All allied accessories should be original and from the same manufacturer. Operating manual, Services manual, error code book, part list and software if any.

Optional

IABP, ETCO

Warranty

Two year with all spare parts, during warranty period firm should maintain

equipments and done PPM as per principle recommendation. If any spare

part required during installation or PPM will be responsibility of the firm.

Firm must send annual PPM schedule with installation report.

Sr. No 28

Clinical specialty Medical and Lab Equipment

Generic Name Automatic Blood pressure monitor with stand

Clinical purpose Used for blood pressure monitoring in different

department.

Quantity 10

Page 41: RAWALPINDI INSTITUTE OF CARDIOLOGY, RAWAL ROAD, …eproc.punjab.gov.pk/AnnualProcurementPlan/annual... · 5 The Clinical Engineering Handbook 01 2016 6 BMET Study Guide (Preparing

Technical specification

Measurement method: Oscillometric

NIBP Measurement range

Systolic:

Diastolic:

Pulse:

40-270 mmHf or better

20-200 mmHg or better

30-240 bpm or better

Display range: 0.-300 mmHg or better

Measurement accuracy

Pressure:

Pulse

+ 3mmHg or better

+ 5mmHg or better

Cuff size:

Thermal printer:

125x300 mm or better

Should allows easy paper roll replacement

and avoid possible paper jam.

Display type: LED Digital

Should have mobile card, adjustable height stool and foot switch.

Should have clock function for date & time

Should have convenient for heart patients, pregnant women’s, patient with back

problem & patient in wheel chair.

Should have safety feature fast stop button, one button operation for stop /

start etc.

Country of origin: US, Europe, Japan or Equivalent

Standards should have CE or other international standard approved.

Accessories

Operating manual, Services manual, error code book, part list and software

if any.

Optional

Nil

Warranty

Two year with all spare parts, during warranty period firm should maintain

equipments and done PPM as per principle recommendation. If any spare

part required during installation or PPM will be responsibility of the firm.

Firm must send annual PPM schedule with installation report.

Sr. No 29

Clinical specialty Medical and Lab Equipment

Generic Name Syringe Pump

Clinical purpose Used for delivery of calculated medicine to patients

Page 42: RAWALPINDI INSTITUTE OF CARDIOLOGY, RAWAL ROAD, …eproc.punjab.gov.pk/AnnualProcurementPlan/annual... · 5 The Clinical Engineering Handbook 01 2016 6 BMET Study Guide (Preparing

Quantity 30

Technical specification

Syringe pump for fluid administration. Flow Rates: 0.1 - 300 ml/hr. Digital display of set parameters. Universal Syringe acceptance capability for disposable, Plastic, Size, 10, 20, 50 ml. Drive Accuracy. ±3% Display of drug name, Infusion rate, infused volume and volume to be infused. Automatic adaptation of controls according to syringe /infusion set. Quick freed/rapid infusion facility. Rechargeable battery and mains operated 220V, 50Hz. Safety alarm audible and acoustic for occlusion end of infusion, low battery.

Accessories

Operating manual, Services manual, error code book, part list and software

if any.

Optional

Docking Station:

Mobile Docking Station for simple and quick pump installation. Features: Designed to save valuable space around the patient bed.

Allow fast and easy pump mounting.

Infusion Stand.

Technical Specification: Power 100-240 VAC, 50/60 Hz

Electrical Safety: EN60601-1 or equivalent FDA, CE of other two

international slandered approved.

Warranty

Two year with all spare parts, during warranty period firm should maintain

equipments and done PPM as per principle recommendation. If any spare

part required during installation or PPM will be responsibility of the firm.

Firm must send annual PPM schedule with installation report.

Sr. No 30

Clinical specialty Medical and Lab Equipment

Generic Name Vain finder

Clinical purpose Used for visualization of veins

Quantity 01

Technical specification

Should detect veins to a depth of 10mm. Sterilize able and medical grade design Easy to clean Handheld or hands-free operation. Battery operated

Page 43: RAWALPINDI INSTITUTE OF CARDIOLOGY, RAWAL ROAD, …eproc.punjab.gov.pk/AnnualProcurementPlan/annual... · 5 The Clinical Engineering Handbook 01 2016 6 BMET Study Guide (Preparing

Accessories

Mobile cart

Charger

Operating manual, Services manual, error code book, part list and software

if any.

Optional

Nil

Warranty

Two year with all spare parts, during warranty period firm should maintain

equipments and done PPM as per principle recommendation. If any spare

part required during installation or PPM will be responsibility of the firm.

Firm must send annual PPM schedule with installation report.

Sr. No 31

Clinical specialty Medical and Lab Equipment

Generic Name Pulse oximeter (Portable)

Clinical purpose Used for check the oxygen saturation of patients.

Quantity 10

Technical specification

Approved and authorized for medical use

Portable Finger Ox meter For emergency Use

Provide SPO2 and pulse rate, pulse strength or more

User friendly with LED display on probe

Auto power shut down after 8-15 seconds when not in use

Low battery indicator flash light

Monitor patient range from pediatrics to adult

Combined monitor and sensor in one, light weight, pocket size.

Battery backup 4hrs or more.

Accessories

Operating manual, Services manual, error code book, part list and software

if any.

Optional

Nil

Warranty

Two year with all spare parts, during warranty period firm should maintain

equipments and done PPM as per principle recommendation. If any spare

part required during installation or PPM will be responsibility of the firm.

Firm must send annual PPM schedule with installation report.

Sr. No 32

Clinical specialty Medical and Lab Equipment

Generic Name Blood Warmer / Plasmatherm

Clinical purpose Used to warm and shake blood / plasma.

Quantity 02

Page 44: RAWALPINDI INSTITUTE OF CARDIOLOGY, RAWAL ROAD, …eproc.punjab.gov.pk/AnnualProcurementPlan/annual... · 5 The Clinical Engineering Handbook 01 2016 6 BMET Study Guide (Preparing

Technical specification:

FOR WARMING OF BLOOD BAGS MINIMUM THREE TO FOUR BAGS CAPACITY Temperature setting: +37ºC to+44ºC Microprocessor controlled unit Blood warmer Voltage: 220 V, 50 Hz

Accessories

Operating manual, Services manual, error code book, part list and software

if any.

Optional

Nil

Warranty

Two year with all spare parts, during warranty period firm should maintain

equipments and done PPM as per principle recommendation. If any spare

part required during installation or PPM will be responsibility of the firm.

Firm must send annual PPM schedule with installation report.

Sr. No 33

Clinical specialty Medical and Lab Equipment

Generic Name Defibrillator (Pacing)

Clinical purpose Used for defibrillation at different departments.

Quantity 06

Technical specification

Biphasic transthoracic (external) defibrillator with TFT/LCD colour display Synchronized output with ECG. Control of energy charging/ delivering on main panel & apex paddle. Charging Indicators. The energy range should be adjustable for paeds and adults up to 200Joules. Charging Time for full energy will be less than 5 sec. Screen Size of approx. inch coloured or more. Display of HR, ECG through paddles and Lead I.II & III patient cable. Built in recorder for printing of full summery on standard 50mm paper. Alarms for High and low Heart rate, low battery warning. AC 220V / 50Hz operated. Built-in Rechargeable battery with charger for minimum 50 shocks at max. energy. Auto tester/self check. External pediatric and adults Paddles, ECG cable. Pacing facility. AED facility with cable.

Accessories

All standard accessories.

2x Pacing cables

Operating manual, Services manual, error code book, part list and software

if any.

Optional

Page 45: RAWALPINDI INSTITUTE OF CARDIOLOGY, RAWAL ROAD, …eproc.punjab.gov.pk/AnnualProcurementPlan/annual... · 5 The Clinical Engineering Handbook 01 2016 6 BMET Study Guide (Preparing

Nil

Warranty

Two year with all spare parts, during warranty period firm should maintain

equipments and done PPM as per principle recommendation. If any spare

part required during installation or PPM will be responsibility of the firm.

Firm must send annual PPM schedule with installation report.

Sr. No 34

Clinical specialty Medical and Lab Equipment

Generic Name Mobile BP Apparatus.

Clinical purpose For BP monitoring in different department.

Quantity 10

Technical specification

CE, ISO /FDA approved.

As per sample approval.

Accessories

Imported trolley .

Optional

Nil

Warranty

Two year with all spare parts.

Sr. No 35

Clinical specialty Medical and Lab Equipment

Generic Name AED

Clinical purpose Used in Ambulance for defibrillation.

Quantity 04

Technical specification

Synchronized output with ECG. The energy range should be adjustable for paeds and adults up to 200Joules. Charging Time for full energy will be less than 5 sec.. Display of HR, ECG . Alarms for High and low Heart rate, low battery warning. AC 220V / 50Hz and 12 v Dc operated. Built-in Rechargeable battery with charger for minimum 50 shocks at max energy. Auto tester/self check. Pacing facility.

Accessories

10x Disposable Electrodes

Operating manual, Services manual, error code book, part list and software

if any.

Optional

Nil

Warranty

Page 46: RAWALPINDI INSTITUTE OF CARDIOLOGY, RAWAL ROAD, …eproc.punjab.gov.pk/AnnualProcurementPlan/annual... · 5 The Clinical Engineering Handbook 01 2016 6 BMET Study Guide (Preparing

Two year with all spare parts, during warranty period firm should maintain

equipments and done PPM as per principle recommendation. If any spare

part required during installation or PPM will be responsibility of the firm.

Firm must send annual PPM schedule with installation report.

Sr. No 36

Clinical specialty Medical and Lab Equipment

Generic Name Echocardiography machine

Clinical purpose Use for echocardiography for OPD patients.

Quantity 01

SPECIFICATION: ECHOCARDIOGRAPHY MACHINE. A complete dedicated digital Echocardiography unit for wide range of premium performance application of cardiovascular imaging in pediatrics and adult. Mobile trolley mounted system with built in workstation / data management system for digital acquisition, storage and review of complete ultrasound studies including static and dynamic clips in DICOM format, read/write zoom. Studies can be reviewed and output to CD / DVD/MOD. The machine must have sharp and high quality image reproduction with heavy duty performance. It should have minimum following specification : DISPLAY: High resolution 1280x 1024 non interlaced, flicker free. Display size Min. 17” Flat/TFT, tilt able and swive able type. OPERATING MODES: B, 2D M-Mode, Power Doppler, HPRF, Spectral Doppler, Color Doppler, Velocity Mode, Pw Doppler, Duplex And Triplex Doppler, CW Doppler Steerable and ECG Gating, CONTROL PANEL: Alphanumeric keyboard with built-in trackball. Direct access to system functions through dedicated keys. Indicator lights identify activated keys. Audio volume control with bidirectional / stereo speakers and foot switch User selectable image magnification control. Adjustable transmit focusing control. Total and Lateral Gran Compensation controls (6 or more). CALIPER / MEASUREMENTS : 6 to 8 calipers for measurement per screen trace length measurements for: Distance, angle, distance depth from skin line, area, circumferences, compound / volume, slope, time, heart rate and acceleration. APPLICATION: Cardiac, Peripheral, pediatric, adult cephalic and transesophageal with all required software for measurements. OPERATING MODES: 2D tissue, 2D angio flow, color M-Mode, tissue velocity M-mode, tissue strain imaging, disynchrony imaging, continuous wave Doppler, tissue m-mode, pulse wave Doppler,

Page 47: RAWALPINDI INSTITUTE OF CARDIOLOGY, RAWAL ROAD, …eproc.punjab.gov.pk/AnnualProcurementPlan/annual... · 5 The Clinical Engineering Handbook 01 2016 6 BMET Study Guide (Preparing

tissue velocity imaging, tissue tracking, tissue synchronization, blood flow imaging, blood flow angio flow imaging. DISPLAY MODES: Live and stored display format: full size and split screen. Review image format: for still and cine, simultaneous capability B+PW, B+ CFM/TVI+PW, CW, B+ or triplex mode, , B+ color split screen display. Tissue Imaging, 2D mode, , M-mode, color Doppler imaging, color flow imaging, color Doppler imaging, color angio, color m-mode, blood flow imaging, blood flow angio imaging, tissue velocity imaging, tissue velocity imaging mode, tissue synchronization imaging mode, PW / HPRF Doppler, CW Doppler, contrast imaging, LVO Contrast, Vascular / abdominal contrast, vascular calculations, cardiac measurements. FRAME RATE Min. 200fps in B-Mode and 100fps in Doppler mode. CINE MEMORY Min. Cine Memory for 1000 frames or 250mb min. IMAGE VIEWING DEPTH: 20 – 280 mm or more for cardiac application IMAGING MODES / TECHNIQUES: Tissue harmonic Imaging, Tissue Doppler Imaging, Color Angio, Tissue Velocity Imaging Tissue Imaging (Display real time Doppler shift information from moving tissue to better visualize and quantity myocardial function). Capability to display time difference in myocardial motion in color for CRT (Cardiac resynchronization therapy. Quantitative strain rate imaging; An advanced quantitative technique of Tissue Doppler Velocity. Strain rate is a measure of the contractile motion of myocardium. Auto-Tracking contrast quantification: quantitative technique for on-line assessment of contrast agent images. Contrast plus sequencing technology: a real time, low mechanical index, non-linear imaging technique for contrast agent examinations. The software should have the capability to show contrast agent only, tissue only or contrast and tissue displays. Contrast Harmonic Imaging capability. Vascular imaging software for carotids with IMT measurement. STRESS ECHO Integrated multi stage stress echo system for advance and flexible stress echo Acquisition and measurement for LV B-Mode imaging. Quantitative analysis for contrast during stress. Examinations Used with TDI protocols. STORAGE DEVICE Built-in MOD/CD / DVD Drive WITH 10 DISKETTES. SYSTEM DYNAMIC RANGE Dynamic range minimum 160 dB or more COMMUNICATION SOFTWARE System should conform to DICOM 3 communication software for: Image Storage, print, Query / Retrieve, Network Communication.

Page 48: RAWALPINDI INSTITUTE OF CARDIOLOGY, RAWAL ROAD, …eproc.punjab.gov.pk/AnnualProcurementPlan/annual... · 5 The Clinical Engineering Handbook 01 2016 6 BMET Study Guide (Preparing

STANDARD TRANSDUCERS: Linear Probe multi frequency to cover frequency of 6.0-8.0 MHz. Multi frequency Phased array sector probe to cover 2.0/2.5 – 4.0MHz. Multi frequency Phased array sector probe to cover 5.0 – 8.0MHz. CW Pencil Probe Multiplane TEE Transducer (3 – 6 MHz) for adults.(Only Two with all machines) POWER REQUIREMENT 220-240VAC 50 Hz

Accessories

Digital Color Thermal Printer with 10 Packs of 100.. Online UPS for 10 min. backup time for complete unit including Printer.(Emerson,Liebert,Chloride,MGE) Digital B/W Thermal Printer with 50 rolls of papers. Jelly 20 L in bottles. FUTURE UPGRADES: The unit should have the capability for up gradation of future software (shall be provided free of cost within the warranty period).

Operating manual, Services manual, error code book, part list and software if any.

Optional

Multiplane TEE Transducer (4 – 6 MHz) for peads(Only One with all machines) Probes: Should be light weight, capable of multiple centre frequencies on transmit for 2D, color Doppler PW/CW (Steerable) Imaging and to perform Harmonics. PORTS: Video Output USB / RS 232 Networking

Warranty

Two year with all spare parts, during warranty period firm should maintain

equipments and done PPM as per principle recommendation. If any spare

part required during installation or PPM will be responsibility of the firm.

Firm must send annual PPM schedule with installation report.

Sr. No 37

Clinical specialty Medical and Lab Equipment

Generic Name Dialysis machine

Clinical purpose Used for acute and chronic kidney failures patient

dialysis

Quantity 01

TECHNICAL SPECFICATION: Touch Panel Color Display 10.4". Syringe pump allows simultaneous infusion of heparin or other prescription drug. Purage infusion, bolus infusion and programmed Infusions are possible.

Page 49: RAWALPINDI INSTITUTE OF CARDIOLOGY, RAWAL ROAD, …eproc.punjab.gov.pk/AnnualProcurementPlan/annual... · 5 The Clinical Engineering Handbook 01 2016 6 BMET Study Guide (Preparing

Air bubble/Blood detector Blood flow is stabilized by 2 roller arms. Blood flow rate is easily adjustable. Parameters display on monitor Blood detect sensor Auto off feature (After disinfection) Fast preparation Reduced disinfection time Display for service diagnostic and calibration. Detects air bubbles in the venous and blood presence to secure patient infusion. Universal Tubing set adult/Peads Automatic Rinse & Disinfection, Thermal / hot 86oc or more method are available as standard. Various rinse program can be set daily & weekly Ultra filtration program & UF profile are available as standard

Electronic Control dial sate flow & blood flow rate with display. Variable bicarb acetate concentration & Automatic control bicarbonate proporation. Computerized Numerical & Graphical Screen. Acetate and Bicarbonate Dialysis Sequential Dialysis Double Needle UF, Bicarbonate & Sodium Profile Advanced accurate KT/V Calculation - dose finder Start up test Back-up Battery 30 min. Volumetric Control UF rate: 0, 0.10 to 5.00L/hr Accuracy: ±30g/hr Dialysis Flow Range (Qd) 300 to 800ml/min Dialysate Temperature: 32.0°C to 39.0°C Blood Pump Rate (Qb): 0, 10 to 600 ml/min Syringe Pump Delivery Range: 0.0 to 9.9 ml/hr Ultrasonic Sensor Venous Pressure Sensor -500 to 500mmHg Arterial Pressure Sensor -500 to 500mmHg Water Rinse Chemical Rinse (disinfection) Acid Rinse Hot Rinse / Hot Citric disinfection Auto Rinse programs Blood Leak Detector Optical Sensor

Optionals:

Blood pressure monitor.

Page 50: RAWALPINDI INSTITUTE OF CARDIOLOGY, RAWAL ROAD, …eproc.punjab.gov.pk/AnnualProcurementPlan/annual... · 5 The Clinical Engineering Handbook 01 2016 6 BMET Study Guide (Preparing

Accessories: Operating manual, Services manual, error code book, part list and software if any.

Warranty

Two year with all spare parts, during warranty period firm should maintain equipments and done PPM as per principle recommendation. If any spare part required during installation or PPM will be responsibility of the firm. Firm must send annual PPM schedule with installation report.

Sr. No 38

Clinical specialty Medical and Lab Equipment

Generic Name Angio jet system

Clinical purpose Used in cath lab for cardiac patients

Quantity 01

Technical specification

LCD Display and Keypad feature Console with Rheolytic thrombectomy catheter. For breaking apart and removing thrombus with a feature of delivering thrombolytic agents on sight by utilizing the Bernoulli principle. Full Range of Catheters for Coronary, Peripheral and AV Access Applications System Self Configures for each catheter model

Catheters are of 4,5 & 6 Fr Catheter Lengths are of 50 - 140cm can treat vessels from 2 to 20mm Internal Diameter Dual Lumen Catheter with option of Rapid Exchange or over the Wire Delivery System Integrated Pump , Catheter and Collection bag are into a single unit . System Preparation time is <2 < omits with Isovoilumetic fluid delivery and removal. Catheters generates 700 bar internal pressure with audiovisual alarm for identification malfunction

Accessories

Operating manual, Services manual, error code book, part list and software

if any.

Optional

Nil

Warranty

Two year with all spare parts, during warranty period firm should maintain

equipments and done PPM as per principle recommendation. If any spare

part required during installation or PPM will be responsibility of the firm.

Firm must send annual PPM schedule with installation report.

Sr. No 39

Clinical specialty Medical and Lab Equipment

Page 51: RAWALPINDI INSTITUTE OF CARDIOLOGY, RAWAL ROAD, …eproc.punjab.gov.pk/AnnualProcurementPlan/annual... · 5 The Clinical Engineering Handbook 01 2016 6 BMET Study Guide (Preparing

Generic Name Open – Irrigation System

Clinical purpose Use in electrophysiology lab for cardiac patients.

Quantity 01

Technical specification

Intelligent User Interface • Comprehensive, real-time diagnostic information on one screen • Large, easy-to-read display can be viewed from a distance • Quick, intuitive menu navigation.

IntellaView™ Infusion Monitoring • Provides real-time feedback on five different saline assessments - Volume Remaining - Low Fluid Warning - Volume Infused - New Saline Bag - Volume Dispensed.

Customizable Memory Buttons • Programmable flow and menu settings can be quickly accessed for future procedures • Store and retrieve procedure parameters for up to three different scenarios.

Bubble and Occlusion Detection • Reliable sensor technology designed to prevent air infusion and occlusion • Simple placement process to ensure accurate tubing alignment • Smaller tubing designed to effectively clear bubbles and increase flow.

Automatic Titration • Intelligent, automatic titration ensures optimal power-to-fluid control • Instant, clear display of titration status.

Maximum Operating Back Pressure 35 psi (standby and ablation) 60 psi (purge) Flow Rate Accuracy -5%/+15% (6-30mL/min) -10%/+20% (2-5mL/min)

+/- 20% (60mL/min). Accessories:

Operating manual, Services manual, error code book, part list and software

if any.

Optional

Nil

Warranty

Two year with all spare parts, during warranty period firm should maintain

equipments and done PPM as per principle recommendation. If any spare

Page 52: RAWALPINDI INSTITUTE OF CARDIOLOGY, RAWAL ROAD, …eproc.punjab.gov.pk/AnnualProcurementPlan/annual... · 5 The Clinical Engineering Handbook 01 2016 6 BMET Study Guide (Preparing

part required during installation or PPM will be responsibility of the firm.

Firm must send annual PPM schedule with installation report.

Sr. No 40

Clinical specialty Medical and Lab Equipment

Generic Name Contamination probe:

Clinical purpose Used in hot lab with survey meter RDS 31.

Quantity 01

Technical specification

radiation detection: gamma-, beta- and alpha-rays

• e e g a ge: ga a > keV, eta a > keV, a d alpha > eV

• dete to t pe: haloge ue hed GM tu e • App o i ate easu e e t a ge: - 10 000 cps

• e d i do a ti e a ea: . . i ; i do thi k ess: . - 2 mg/cm2

• se siti it : . ps fo u ifo “ / Y sou e of . B /

• et a ta le o d, le gth - 2500 mm (31.50 in - 98.42 in)

• te pe atu e a ge: ope atio : -25°C to +55°C (-13°F to +131°F); storage: -40°C to

+70°C (-40°F to +158°F)

• hu idity: 0 - 95% relative humidity, non-condensing

• pa ake di e sio s: . . . i total p o e le gth mm (11.6 in

Accessories:

Operating manual, Services manual, error code book, part list and software

if any.

Optional

Warranty

Two year with all spare parts, during warranty period firm should maintain

equipments and done PPM as per principle recommendation. If any spare

part required during installation or PPM will be responsibility of the firm.

Firm must send annual PPM schedule with installation report.

Sr. No 41

Clinical specialty Medical and Lab Equipment

Generic Name Syringe Pump digital injector

Clinical purpose Used for patients to inject adenosine

Quantity 01

Technical Specification: Free flow protection. Automatic calculation of rate based on does increase in mg, microgram, mmol, weight and time related e.g microgram /kg/min.

Accessories:

Operating manual, Services manual, error code book, part list and software

if any.

Optional

Page 53: RAWALPINDI INSTITUTE OF CARDIOLOGY, RAWAL ROAD, …eproc.punjab.gov.pk/AnnualProcurementPlan/annual... · 5 The Clinical Engineering Handbook 01 2016 6 BMET Study Guide (Preparing

Nil

Warranty

Two year with all spare parts, during warranty period firm should maintain

equipments and done PPM as per principle recommendation. If any spare

part required during installation or PPM will be responsibility of the firm.

Firm must send annual PPM schedule with installation report.

Sr. No 42

Clinical specialty Medical and Lab Equipment

Generic Name Printer for dose calibrator (Hot Lab)

Clinical purpose Used to print reports of dose calibrator.

Quantity 01

Technical specification

Dose Calibrator (VDC-405 Version 3.31, Veenstra Instruments) or equivalent.

HP LaserJetP3015 or equivalent.

Accessories:

Operating manual, Services manual, error code book, part list and software

if any.

Optional

Warranty

Two year with all spare parts, during warranty period firm should maintain

equipments and done PPM as per principle recommendation. If any spare

part required during installation or PPM will be responsibility of the firm.

Firm must send annual PPM schedule with installation report.

Sr. No 43

Clinical specialty Medical and Lab Equipment

Generic Name Printer for spectro analyzer system,

Clinical purpose To be used for the analysis of thallium on weekly

basis.

Quantity 01

Technical specification

Spectro AnalyzerTM SpectroWipeTM, Wipe Test Counting system, 1024-Channel MCA with Nuclide Identification, SW1000-ID Version 3.1.0 (AccuSync Medical Research Corporation) or equivalent.

Following mentioned printers are recommended and compatible with above mentioned equipment

Lexmark E260D, Lexmark E260DN, Brother HL-2270DW, Brother HL-2270 to be used for the analysis of thallium on weekly basis.

Accessories:

Page 54: RAWALPINDI INSTITUTE OF CARDIOLOGY, RAWAL ROAD, …eproc.punjab.gov.pk/AnnualProcurementPlan/annual... · 5 The Clinical Engineering Handbook 01 2016 6 BMET Study Guide (Preparing

Operating manual, Services manual, error code book, part list and software

if any.

Optional

Warranty

Two year with all spare parts, during warranty period firm should maintain

equipments and done PPM as per principle recommendation. If any spare

part required during installation or PPM will be responsibility of the firm.

Firm must send annual PPM schedule with installation report.

Sr. No 44

Clinical specialty Medical and Lab Equipment

Generic Name Dose Calibrator

Clinical purpose To measure radioactive medicine.

Quantity 01

Technical specification

Ionization Chamber

• T pe: Thi all, deep well, high pressure

• Di e sio s: deep . dia. • Ca li g: . ’ i te o e ti g a le

Measurement Range

• T pe: Auto Ra gi g

• A ti it : GB Ci , a . • Resolutio : . MB . µCi , a . Display Screen

• T pe: Dot Matrix Liquid Crystal Display

• Fo at: Di e t eadi g i B o Ci • B /Ci Readi g: Use sele ta le o fi ed

• Values Displa ed: Nu lide a e Ato i s ol, Mass u e , ali atio u e

Electrometer

• A u a : Bette tha ± %

• Li ea it : Withi ± 2%

• Respo se Ti e: Withi se ., to se . fo e lo a ti it sa ples use selectable

average period)

Repeatability of Measurement

• Repeata ilit : Withi ± % ithi hou s, du i g hi h ti e the ali ato is on all the

time.

Molybdenum-99 Assay

• Methods: Ca iste o CAPMAC

• Measu ed Values: Mo-99 elution, Tc-99m, Tc-99m/Mo-99 RatioTests

• Diag osti s: Full test of p og a , s ste e o ies

• Qua te l : Dail , A u a a d Li ea it

• Dail : Auto )e o, Auto Ba kg ou d Adjust, Data Che k, A u acy and Constancy Standard

Source Data

• “ ste Me o : Co-57, Co-60, Ba-133, Cs-137 Standard Sources

Nuclear Data

• Nu lea “etti g Ke s: P e-set, 5 User

Page 55: RAWALPINDI INSTITUTE OF CARDIOLOGY, RAWAL ROAD, …eproc.punjab.gov.pk/AnnualProcurementPlan/annual... · 5 The Clinical Engineering Handbook 01 2016 6 BMET Study Guide (Preparing

• “ ste Me o : O e u lides / al u e a d half-life)

• A p e-set key measures up to 2.0 Ci (74.0 GBq) of F-18

• Co pati ilit : “ta da d Nu lea Medi i e Ma age e t “ ste s

Power Requirements

• -240 VAC (50/60Hz) 90 MA

Accessories:

Operating manual, Services manual, error code book, part list and software

if any.

Optional

Warranty

Two year with all spare parts, during warranty period firm should maintain

equipments and done PPM as per principle recommendation. If any spare

part required during installation or PPM will be responsibility of the firm.

Firm must send annual PPM schedule with installation report.

Sr. No 45

Clinical specialty Medical and Lab Equipment

Generic Name Co-57 flood source

Clinical purpose Used for daily QC of Gamma camera.

Quantity 01

Technical specification

(Eckert & Ziegler Germany product cat no. CTRF10017). Co-57, 10mCi, Rectangular Flood Src

w/ProKem Tech

Transparent Flood Source.

Active dimensions:410 mm x 260

Overall dimensions: 445 x 375 x 8 mm

CE-marked

Activity tolerance: +/- 15%

Accessories:

Operating manual, Services manual, error code book, part list and software

if any.

Optional

Nil

Warranty

Two year with all spare parts, during warranty period firm should maintain

equipments and done PPM as per principle recommendation. If any spare

part required during installation or PPM will be responsibility of the firm.

Firm must send annual PPM schedule with installation report.

Sr. No 46

Clinical specialty Medical and Lab Equipment

Generic Name Co-57 point source

Clinical purpose Used for daily QC of Gamma camera.

Page 56: RAWALPINDI INSTITUTE OF CARDIOLOGY, RAWAL ROAD, …eproc.punjab.gov.pk/AnnualProcurementPlan/annual... · 5 The Clinical Engineering Handbook 01 2016 6 BMET Study Guide (Preparing

Quantity 01

Technical specification

(Eckert & Ziegler Germany product cat no. 3807) Single-encapsulated stainless steel

point source. ISO rating: C66444. 1mCi = 37MBq. Part#CO738070001M.

Accessories:

Operating manual, Services manual, error code book, part list and software

if any.

Optional

Nil

Warranty

Two year with all spare parts, during warranty period firm should maintain

equipments and done PPM as per principle recommendation. If any spare

part required during installation or PPM will be responsibility of the firm.

Firm must send annual PPM schedule with installation report.

Sr. No 47

Clinical specialty Medical and Lab Equipment

Generic Name Pocket dosimeter

Clinical purpose Used to measure instant radiation of individuals.

Quantity 03

Technical specification

Radiological Characteristics

Radiation detected: - gamma and X-rays

• Dete to s: - energy compensated si-Diode

• Measu e e t a ge: dose: μs - 9.99 sv or 0.1 mrem - 999 rem –

dose ate: μs /h - 3 sv/h or 0,5 mrem/h - 300 rem/h

• Cali atio : - better than ±5% (cs-137, 662 keV at 2 msv/h), Hp(10)

• E e g espo se: - Hp(10), 55 keV - 3 MeV, better than ±25%, up tp 6 MeV, better than ±35%

Dose rate linearity:

- better than ±15%, up to 3 sv/h (300rem/h)

Functional Characteristics

• Ala th esholds:

- six preset values each for integrated dose and dose rate, manually selectable by push-

button

• F o t pa el push

-button functions:

- toggle between dose and dose rate display

- switch On/OFF

- chirp On/OFF

- reset integrated dose

- change alarm thresholds

- activate battery test

• Audi le ala s:

Page 57: RAWALPINDI INSTITUTE OF CARDIOLOGY, RAWAL ROAD, …eproc.punjab.gov.pk/AnnualProcurementPlan/annual... · 5 The Clinical Engineering Handbook 01 2016 6 BMET Study Guide (Preparing

- seven separate alarms, sound level typically better than 85 dBA at 30 cm

- integrated dose, dose rate, dose overflow, dose rate overflow at 3 sv/h or 300 rem/h

- low battery 1 and 2

- defect

Power Requirement

-100-240VDC

Reader communication:

- by infrared through bottom part; by using ADR-1 Reader Head in combination with RADOs

Pc software

Reader and software for dosimeter configuration calibration or access control (Qty 1)

Accessories:

Operating manual, Services manual, error code book, part list and software

if any.

Optional

Warranty

Two year with all spare parts, during warranty period firm should maintain

equipments and done PPM as per principle recommendation. If any spare

part required during installation or PPM will be responsibility of the firm.

Firm must send annual PPM schedule with installation report.

Radiology

Sr. No 48

Clinical specialty Medical and Lab Equipment

Generic Name Workstation for CT

Clinical purpose Used to warm and shake blood / plasma.

Quantity 02

Technical specification FDA / CE approved, Independent, multimodality, fully Functional. All the companies will give undertaking that the offered workstation has been supplied by them worldwide. High speed link to operator console on DICOM network. System architecture and operating system: a: Dual processor Xeon. b: 2.66 GHz or more. c: 512 Cache or more. d: Graphic card & Network card. Licensed Software’s: latest Windows systems or Linux; MS Office, Norton antivirus (current and upgradeable). Should have one high resolution TFT monitor of 18 inches or more. DVD writer / CDR. DICOM -3 Viewer with universal PC display capability (Licensed). Laser black & white / Color printer, A4 size, 2400 dpi or higher, Two paper trays for A4 / letter size media (HP, Lexmark, Xerox) Network ready. UPS, 3 kV (x 03) (Branded, Dry batteries) .capable of providing 20 minutes of backup for workstations (MG, APC, MC, Chloride).

Page 58: RAWALPINDI INSTITUTE OF CARDIOLOGY, RAWAL ROAD, …eproc.punjab.gov.pk/AnnualProcurementPlan/annual... · 5 The Clinical Engineering Handbook 01 2016 6 BMET Study Guide (Preparing

Workstation Software a: All the latest available cardiac and whole body software will be provided by the vendor as standard, including reporting packages. b: Software up gradation of all existing applications for at least next 5 years. c: Following software should be provided at ALL workstations: 3-D reconstruction display. a: Maximum and minimum intensity projections. b: Multi-planner and curved planer reconstruction. c: 3-D Shaded Surface Display. d: 3-D Volume Rendering software. e: 3-D Virtual endoscopy, colonoscopy, bronchoscopy. CT Angiography Advanced coronary vessel analysis. Calcium scoring with ECG gating and prospective & retrospective reconstruction. Cardiac function analysis, complete package. Advanced Pheripheral / General vessel analysis. Lung nodule detection & analysis. Brain Perfusion analysis. Fusion software for correlative imaging. DICOM 3.0 DICOM 3 ready (multi-vendor and multimodality compatible) for Send, Receive, Archive, Retrieve and Print, on main consol and workstations. UPGRADEABILITY a: All vendors will quote their latest systems. b: The System should have an upgrade route to higher version. QUALITY AND SAFETY STANDARDS a: MDD (CE) compliance. b: FDA 510 K approval. POWER REQUIREMENT Three-phase with line voltage of 220 V, 50 Hz. Fluoroscopy with real time imaging and display of at least 8 frames / sec with required hardware & software. One high resolution in-room TFT monitor of at least 15 inches or more on mobile base / ceiling mounted.

Accessories

Operating manual, Services manual, error code book, part list and software

if any.

Optional

Nil

Warranty

Two year with all spare parts, during warranty period firm should maintain

equipments and done PPM as per principle recommendation. If any spare

part required during installation or PPM will be responsibility of the firm.

Firm must send annual PPM schedule with installation report.

Page 59: RAWALPINDI INSTITUTE OF CARDIOLOGY, RAWAL ROAD, …eproc.punjab.gov.pk/AnnualProcurementPlan/annual... · 5 The Clinical Engineering Handbook 01 2016 6 BMET Study Guide (Preparing

Sr. No 49

Clinical specialty Medical and Lab Equipment

Generic Name Portable ultra sound

Clinical purpose Used to warm and shake blood / plasma.

Quantity 02

Technical specification

A complete dedicated high end digital Color Doppler Ultrasound unit for wide range of premium performance application of Abdominal, OBS/GYN, Urology, and vascular imaging in pediatrics and adult. Mobile Portable system with built in workstation / data management system for digital acquisition, storage and review of complete ultrasound studies including static and dynamic clips in DICOM format, read/write zoom. Studies can be reviewed and output to CD / DVD/USB. System Should have built-in battery. The machine must have sharp and high quality image reproduction with heavy duty performance. It should have minimum following specification : DISPLAY: High resolution non interlaced, flicker free 15” LCD/TFT display tilt able. OPERATING MODES: B, 2D M-Mode, Power Doppler, HPRF, Spectral Doppler, Color Doppler, Pw Doppler, Duplex And Triplex Doppler, IMT imaging, Contrast Imaging, Panoramic Imaging, Compound Imaging, 3D/4D imaging. CONTROL PANEL: Alphanumeric keyboard with built-in trackball. Direct access to system functions through dedicated keys. Indicator lights identify activated keys. Audio volume control with bidirectional / stereo speakers and foot switch. User selectable image magnification control. Adjustable transmit focusing control. Total and Lateral Gain Compensation controls (6 or more). 2 Active Probe connectors CALIPER / MEASUREMENTS : 4 to 8 calipers for measurement per screen trace length measurements for: Distance, angle, distance depth from skin line, area, circumferences, compound / volume, OBS/GYN measurements, Urological measurements, Vascular Measurements with IMT. APPLICATION: Abdominal, OBS/GYN, Urology, vascular, Small Parts, Peripheral for pediatric, adult with all required software for measurements. DISPLAY MODES: Live and stored display format: full size and split screen. Review image format: for still and cine, simultaneous capability B+PW, B+ CFM +PW, B+ or triplex mode, B+ color split screen display. 2D mode, , M-mode, color Doppler imaging, color Doppler imaging, color m-mode, PW / HPRF Doppler, IMT, Panoramic Imaging, Vascular imaging , vascular calculations. CINE MEMORY Min. Cine Memory for 8000 frames or 250mb min. IMAGE VIEWING DEPTH:

Page 60: RAWALPINDI INSTITUTE OF CARDIOLOGY, RAWAL ROAD, …eproc.punjab.gov.pk/AnnualProcurementPlan/annual... · 5 The Clinical Engineering Handbook 01 2016 6 BMET Study Guide (Preparing

30 – 300 mm or more for cardiac application IMAGING MODES / TECHNIQUES: Tissue harmonic Imaging, Power Doppler Imaging, Vascular imaging software for carotids STORAGE DEVICE Built-in CD / DVD/ USB Drive SYSTEM DYNAMIC RANGE Dynamic range minimum 200 dB or more COMMUNICATION SOFTWARE System should upgradable for DICOM 3 communication software for: Image Storage, print, Query / Retrieve, Network Communication. PORTS: Video Output, USB / RS 232, Networking POWER REQUIREMENT 220-240VAC 50 Hz Battery Back up 3-4 hour built in battery backup.

FDA (510 k) and CE approved.

Accessories

Multi frequency Convex Probe to cover 2.5 -6.0MHz. Multi frequency Linear Probe to cover 7.5-12.0 MHz.

Imported Trolley

Thermal Printer 256-Gray scale

50 High Density / High Glossy thermal paper Rolls

Gel: 20 liters

Operating manual, Services manual, error code book, part list and software

if any.

Optional

Nil

Warranty

Two year with all spare parts, during warranty period firm should maintain

equipments and done PPM as per principle recommendation. If any spare

part required during installation or PPM will be responsibility of the firm.

Firm must send annual PPM schedule with installation report.

Infection Control Department

Sr. No 50

Clinical specialty Medical and Lab Equipment.

Generic Name Fogging Machine.

Clinical purpose Used to treat the air and surfaces in a room.

Page 61: RAWALPINDI INSTITUTE OF CARDIOLOGY, RAWAL ROAD, …eproc.punjab.gov.pk/AnnualProcurementPlan/annual... · 5 The Clinical Engineering Handbook 01 2016 6 BMET Study Guide (Preparing

Quantity 01

Technical specification:

Electric turbine of 1000-1100 watts (range). . Rotation speed of 20000-22000 rpm (range). . No liquid injection pumps. . Dry mist projection by Venturi effect up to 15 meters from the appliance. . Speed of mist exit. 80m/s. . Particules size = 5 microns. . Adjustable flow from 1 to 5 ml/m³. . Automatic stop and delayed start. . Fire-extinction hood. . Uses non toxic biodegradable products. Country of Origin: USA, Europe, Japan. Accessories:

Calorimeter Strips For Process Monitoring 500 Strips Disinfectant solution (Preventive Treatment) 200 Litre Disinfectant Solution (Curative Treatment) 100 Litre

Optional:

Nil

Warranty:

Two year with all spare parts, during warranty period firm should maintain

equipments and done PPM as per principle recommendation. If any spare

part required during installation or PPM will be responsibility of the firm.

Firm must send annual PPM schedule with installation report.

Page 62: RAWALPINDI INSTITUTE OF CARDIOLOGY, RAWAL ROAD, …eproc.punjab.gov.pk/AnnualProcurementPlan/annual... · 5 The Clinical Engineering Handbook 01 2016 6 BMET Study Guide (Preparing

DEMAND FOR “PLANT AND MACHINERY” FOR TENDER 2016-17

S/N Item Name Description Qty In

Hand

Qty

Required

Estimated

Cost

1 Moving Walk for OPD

Patients For Heart Patients at OPD Entrance 00 02 20 M

2 Bed Disinfection System Disinfection System for Pours,

goods, mattress and beds etc 00 01 17 M

3 Reverse Osmosis System For HVAC circulation water and

laundry to reduce the clotting effect 03 02 1.6 M

4 Incinerator To handle infective waste 00 01 20 M

5 Air Curtain

This air curtain used to separate

inside and outside air without

blocking an open doorway

02 04 0.8 M

6 Feed Water Pump (Multi

Stage) For boiler feed water 00 01 0.04 M

7 Water Pressure Pump &

Other Accessories For washing of RIC vehicles 00 02 0.08 M

8

Drinking Water Filtration

Plant Room of Drinking

Water With Chillers

For patient and their visitors in

waiting area 00 01 1 M

9 Spot Welding Machine

For dry battery cell repairing.

Compressor and electric (220/50)

operated. Only machine required

compressor is already in stock.

With one year warranty

00 01 0.08 M

10 KVP Meter

For Radiology Equipment

Calibration, best quality sample/

brusher must show before quoting

00 01 0.1 M

11 MA Meter

Use for X -Ray Tube mA

Adjustment for Radiology

Equipment, best quality subject to

the sample.

00 01 0.1 M

12 Acrylic Sheet For X-Ray machine calibration 00 01 0.04 M

13 Collimator Test Tool For X-Ray machine calibration 00 01 0.04 M

14 Beam Alignments Tool For X-Ray machine calibration 00 01 0.05 M

15 Sound Level Meter (Tube

Head) For X-Ray machine calibration 00 01 0.05 M

16 DAM (Dose Area Product

Meter)

Used for Area dose measurement,

to be feted with TOSHIBA X-ray

machines

00 03 0.15 M

17 Mobile X-Ray Radiation

Protector

Used for radiation protection of

staff and patients during X-ray

procedure at ITC, CCU and wards

00 02 0.05 M

18 Lead Barrier

Used for radiation protection during

X-ray procedure at X-Ray room and

nuclear department

00 02 0.05 M

TOTAL : 61.23 M

Page 63: RAWALPINDI INSTITUTE OF CARDIOLOGY, RAWAL ROAD, …eproc.punjab.gov.pk/AnnualProcurementPlan/annual... · 5 The Clinical Engineering Handbook 01 2016 6 BMET Study Guide (Preparing

SPECIFICATION OF “PLANT AND MACHINERY” FOR TENDER 2016-17

Sr. No 1 Clinical Specialty Plant & Machinery

Generic Name Moving Walk for OPD Patients

Quantity 02

Clinical Purpose Lifting of heart Patient at OPD Entrance

TECHNICAL SPECIFICATION: Installation site: Outdoor Standard: EN115 or equivalent Step width (mm): 1000 Horizontal Steps: 2 up and down Vertical rise: H = 3650mm Horizontal span: L = standard Inclination: 12º Speed: 0.5 m/s Power supply: 3Ф, 380 ± 10% V AC, 50HZ Lighting supply: 1Ф, 220 ± 10% V AC, 50HZ Start: Star-delta Arrangement / Group control: Parallel / Single Installation: Outdoor Complete Standard Installation: Balustrade: Vertical (900mm) Balustrade panel: Tempered safety glass (10mm) Balustrade profile: Stainless steel or better Handrail & colour: Black Inner & outer decking: Stainless steel or better Skirting: Stainless steel or better Panel of landing plate: Steel with antiskid trough Step: Stainless steel with yellow plastic line Combs: Aluminium Truss: Angle steel Gear box: Siemens or better PLC: Mitsubishi or better Step chain: NSK or better Safety Function:

1. Skirting contact 2. Handrail entrance contract 3. Broken step-chain contact 4. Phase monitor 5. Motor overload and overheat contact 6. Comb contact 7. Emergency stop button 8. Main drive – chain contact 9. Reversal prevent

10. Step sagging contact 11. Fault display 12. Auto lubrication

Page 64: RAWALPINDI INSTITUTE OF CARDIOLOGY, RAWAL ROAD, …eproc.punjab.gov.pk/AnnualProcurementPlan/annual... · 5 The Clinical Engineering Handbook 01 2016 6 BMET Study Guide (Preparing

Accessories: Standard accessories

Warranty : Five year with all spare parts, during warranty period firm should maintain equipments and done PPM as per principle recommendation. If any spare part required during installation or PPM will be responsibility of the firm. Firm must send annual PPM schedule with installation report

INSTALLATION:-

Installation, lifting, civil and electric work is total responsibility of supplier. Note: Before quoting bid supplier must visit the site. Any other accessories required for completing the installation and to bring the units to operational state is responsibility of supplier.

Optional: Nil

Sr. No 2 Clinical Specialty Plant & Machinery

Generic Name Bed Disinfection System

Quantity 01

Clinical Purpose Disinfection system for pours, goods, mattress and beds etc

TECHNICAL SPECIFICATION: Steam disinfection system for solid and porous goods

To be used for disinfection of:-

Mattresses

Bed linen

Clothing

Waste

Utensils

According to 93/42/EEC MDD and CE marked.

Capacity according to DIN 13014-M 2000:6 mattresses.

All processes should be valid table and run fully automatically by following pulsing vacuum

method. The processing of the goods should be traceable and verifiable.

Auto Start function to start the vacuum program and preheating of the chamber. Standby

function should automatically be activated upon completion of the last program cycle.

Display of remaining cycle time.

Touch screen for program menu & Operation of the machine.

Operate with central steam supply.

Two stage water ring vacuum pump with water saving system.

The batch protocol can be printed either on an integrated/external printer. In addition, process

data can be transferred to a PC for storage.

WARRANTY:-

2 years parts & service warranty.

INSTALLATION:-

Installation, lifting, civil and electric work is total responsibility of supplier.

Note: Before quoting bid supplier must visit the site.

Any other accessories required for completing the installation and to bring the units to

operational state is responsibility of supplier.

Country of Origin: USA, Europe, Japan

Accessories: Air filter for the decontamination of exhausted air

Page 65: RAWALPINDI INSTITUTE OF CARDIOLOGY, RAWAL ROAD, …eproc.punjab.gov.pk/AnnualProcurementPlan/annual... · 5 The Clinical Engineering Handbook 01 2016 6 BMET Study Guide (Preparing

Side facing and additional panelling

Loading carts

Mobile containers for the transport of infectious goods

Warranty : Two year with all spare parts, during warranty period firm should maintain equipments and done PPM as per principle recommendation. If any spare part required during installation or PPM will be responsibility of the firm. Firm must send annual PPM schedule with installation report INSTALLATION:-

Installation, lifting, civil and electric work is total responsibility of supplier. Note: Before quoting bid supplier must visit the site. Any other accessories required for completing the installation and to bring the units to operational state is responsibility of supplier.

Optional: Nil

Sr. No 3 Clinical Specialty Plant & Machinery

Generic Name Reverse Osmosis System

Quantity 02

Clinical Purpose For HVAC circulation water, to reduce the clotting effect

TECHNICAL SPECIFICATIONS PLANT DESIGN BASIS 1. FEED WATER PUMP Qty 01 Flow Rate 2 m3/ hr Max Pressure 30-40 psi 2800 rpm Line Size 1" Type Complete S.S 2. MULTI-MEDIA FILTER Qty 01 Head Valve Control System Manual Vessel Make & Origin Pentair Material FRP Lining Rubber / Fiber Vessel Size 13” x 54” Line Size (in /out) 1" Head Valve Type Manual Filtration Media Multiple Media, Quartz Gravel Sand Media Imported 3. GRANULAR ACTIVATED CARBON FILTER Qty 01 Head Valve Control System Manual Vessel Make & origin Pentair Material FRP Lining Rubber / Fiber Vessel Size 13” x 54” Line Size (in /out ) 1" Head Valve Type Manual Media Activated Carbon Carbon Media Imported 4. WATER SOFTENER

Page 66: RAWALPINDI INSTITUTE OF CARDIOLOGY, RAWAL ROAD, …eproc.punjab.gov.pk/AnnualProcurementPlan/annual... · 5 The Clinical Engineering Handbook 01 2016 6 BMET Study Guide (Preparing

Qty 01 Head Valve Control System Manual Make &origin Pentair Material FRP Lining Rubber / Fiber Vessel Size 13” x 54” Line Size (in /out) 1" Head Valve Type Manual Media Type Caution 5. MICRON FILTERS SYSTEM Water Flow Rat 2 m3/hr Max Filtration Rating 5/1 Micron Filtration Type Paper Plates Types / PP F Housing Material HDPE Filters Dimensions 20” No of Filters per bank 1 Nos 6. REVERSE OSMOSIS SYSTEM (RO) Quantity 01 Dimensions 4”x40” System Recovery 70% Rejection 97-99% 7. SKID STRUCTURE Compact Skid Structure Rust Proof S.S Law Space Occupation High Aesthetic Values 8. RO HIGH PRESSURE PUMP Quantity 01 Type Multistage Water Flow 2 m3 /hr Pump Head 150 PSI Max Power 220 V, I phase, 50Hz 9. RO MEMBRANE Quantity 02 No. Type 4x40” Model BW-30-40-40 10. MEMBRANE PRESSURE VESSELS Quantity 02 No. Material of Construction FRP Pressure Rating 200 psi Made Flourida 11. FLOW METER Quantity 2 Nos. Manufacture Blue White (USA) Range As required Type Analog 12. TDS METER Quantity 01 No Manufacture Imported Range 0-1000 micro- S/cm Type Digital 13. PRESSURE GAUGE Quantity 02 No Range 0-350 psi Size 63 mm Type Liquid Filled, Panel Mounting

Page 67: RAWALPINDI INSTITUTE OF CARDIOLOGY, RAWAL ROAD, …eproc.punjab.gov.pk/AnnualProcurementPlan/annual... · 5 The Clinical Engineering Handbook 01 2016 6 BMET Study Guide (Preparing

Material of Construction Full SS 316 14. LOW PRESSURE SWITCH Quantity 02 No Range 40-150 psi 15. HIGH PRESSURE PIPES AND FITTINGS All high pressure pipes and fittings will be high standard. 16. LOW PRESSURE PIPES AND FITTINGS All low pressure pipes and fitting will be UPVC, Sch 80 or equivalent. 17. MAIN SYSTEM CONTROL PANEL Automatic operation of the unit through Sami auto circuit. Safe Operation of High Pressure pump. Time delayed start up. Hand / auto operation of the system. 18. RAW WATER STORAGE TANK 200 GLS Qty 01 19. TREATED WATER STORAGE TANK 200GLS Qty 01 20. BOOSTER PUMP Qty 01 Flow Rate 1 m3 / hr Max Pressure 30-40 psi 2800 rmp Line Size 3/4” Type Complete S.S 21. WATER LEVEL SENSOR Qty 02 22. ULTRA VIOLET 36” SS

Accessories: Standard accessories

Warranty : Two year with all spare parts, during warranty period firm should maintain equipments and done PPM as per principle recommendation. If any spare part required during installation or PPM will be responsibility of the firm. Firm must send annual PPM schedule with installation report

INSTALLATION:-

Installation, lifting, civil and electric work is total responsibility of supplier.

Note: Before quoting bid supplier must visit the site.

Any other accessories required for completing the installation and to bring the units to operational

state is responsibility of supplier.

Optional Nil

Sr. No 4 Clinical Specialty Plant & Machinery

Generic Name Incinerator

Quantity 01

Clinical Purpose To handle infective waste

TECHNICAL SPECIFICATIONS I- RUNNING PRINCIPLE

Page 68: RAWALPINDI INSTITUTE OF CARDIOLOGY, RAWAL ROAD, …eproc.punjab.gov.pk/AnnualProcurementPlan/annual... · 5 The Clinical Engineering Handbook 01 2016 6 BMET Study Guide (Preparing

Supply and the installation of an incinerator for the destruction of hospital and medical waste of 100-120 kg/h. lower calorific power (L.C.P) of this waste will be average 3,500 kcal/kg. Incinerator must be able to work according to variable operating rages up to 8-12h/24. * The temperature is modulated in varying flow and percentage in oxygen. Combustion gas is re-burned in the post-combustion chamber at a temperature of min. 1,100 °C. * The control panel will be fitted with a functional synoptic view showing the operating situation of the whole installation. Accessibility to all equipment and sets of easy and rapid measure points in order to analyse rejected gas (such as dusts, carbon monoxide, HCL, T°...) by accepted organisms. Electrical connection pre-wired and fuel pipes in place, making installation easier at site. II- SPECIAL COMBUSTION CHAMBER FOR HOSPITAL WASTE The combustion chamber of incinerator should be adequate capacity to handle a consignment of 100-120 kg of hospital and medical waste. The size of the waste charging door is 70 x 70 cm approx in order to well introduce waste into the combustion chamber. The first phase of the incineration is combustion without air comparable to gasification. The combustion chamber should be thick sheet steel (3 to 10 mm) especially elaborated or batter material. The insulation of the combustion chamber should be composed of refractory bricks having high content aluminum and isolation bricks in order to assure a minimum temperature on the outside sheet metal. Composition of the refractory lining: - Refractory bricks : . Thickness : 110 mm approx . Maximum temperature : 1,400 °C or more . Nature : 42% of Al203 - Insulator : . Thickness : 80 mm approx . Maximum temperature : 1,000 °C or more . Nature : Calcium silicate Combustion burner : The combustion chamber should be composed of one hearth of combustion. The combustion hearth should be fitted with one burner enabling to assure a correct combustion temperature for the complete destruction of the waste. Burner should mono-bloc casing type with horizontal flame, ignition and electronic ignition safety, permanent ventilation, control electro valve and insulation valve. Air Supply Fan: Electro-ventilator distributes the primary and secondary air in the incinerator. This combustion hearth should be equipped with primary air nozzles (8 nozzles) to assure the perfect combustion. * The air injection will be done with a high pressure of 220 mm H20. * This pressure allows to pierce the burning waste bulk and to avoid the unburned ratio. * The adjustment of air rates is carried out through valves and servomotor

Page 69: RAWALPINDI INSTITUTE OF CARDIOLOGY, RAWAL ROAD, …eproc.punjab.gov.pk/AnnualProcurementPlan/annual... · 5 The Clinical Engineering Handbook 01 2016 6 BMET Study Guide (Preparing

according to the automatic cycle controls. III- POST-COMBUSTION CHAMBER

* The second phase of incineration is a post-combustion of the flue gas produced by the combustion chamber at high temperature. * The post-combustion chamber should be situated on the top of the combustion chamber so as to re-burn easily the flue gas. The high content of CO in these gases permits a re-lighting by simple air injection with the post-combustion burners. The post-combustion of gases takes place at a temperature of 1,100°C during 2 seconds. The cylindrical form of the post-combustion chamber, combined with Vortex effect in the secondary and tertiary air injection, which have been particularly designed and patented by ATI MULLER, enabling to assure the achievement of very low hydrocarbon refuse. This contributes also to the limitation of soot (carbon) in the downstream and of the quantity of solid to be treated in the dust remover. * The post-combustion should be lined with high thermal insulating materials with a thickness of 150 mm (approx) of refractory bricks and 85 mm of insulator. IV- CHIMNEY The inside of the chimney should be lined with refractory like the post-combustion chamber with a thickness of 120 mm(approx) of refractory bricks and 30 mm (approx)of insulator. The height of chimney should be 8 m (approx) from the ground putting the incinerator and its interior diameter should be 500 mm (approx). The chimney should be fitted with sampling port for the collection and measuring of gas samples, the sampling port should be of 300 mm x 100 mm in accordance with the French standard NFX44052 provided with a cover to be opened and closed when necessary without affecting the chimney’s function. V- ELECTRIC CONTROL AND REGULATION PANEL

All installation will be confirmed with regulations in force.

Power supply is 380 v, three phases.

The installed materials will be well-known marks Schneider, LEGRAND, functioning at the frequencies of 50/60 Hz.

Dust-tight control box contains :

One circuit breaker switch for each engine (ventilator and burners).

Four timers with adjustable delay time for controlling each engine (ventilator and burners)

One digital display regulator for the combustion temperature.

One digital display regulator for the post-combustion temperature.

Control box in compliance with current standards.

VI- TECHNICAL FEATURES

Designation Model CP 100

Operation time

8-12/24 h

Average L.C.P (Lower Calorific Power) of waste

3 500 kcal/kg

Volume of combustion chamber 2 m3 (approx)

Page 70: RAWALPINDI INSTITUTE OF CARDIOLOGY, RAWAL ROAD, …eproc.punjab.gov.pk/AnnualProcurementPlan/annual... · 5 The Clinical Engineering Handbook 01 2016 6 BMET Study Guide (Preparing

Temperatures * Combustion * Post-combustion

900 °C or more 1,100 °C or more

Burners power * Combustion * Post-combustion

300 kW (approx) 300 kW (approx)

Installed electrical power 4 kW

Gases dwell time in the post- combustion chamber at 1100 °C

2 seconds or less

* Opening in the roof for the passing of the chimney with tight connection

* Civil engineering works * Building (dimension of building as per requirement) * High and low ventilation * Connection of electric to our control panel (three phases 380 Volts + neutral + earth)/50Hz * Connection of fuel oil pipes to our burners One incinerator with pyrolytic combustion of C.P.100 type contains :

One combustion chamber

One post-combustion chamber

One control box One set of accessories to handle ash: a metallic scraper, an ash box with carrying handles.

Complete installation that is entirely autonomous and placed in container

Accessories: Loading carts 02 Standard accessories

Warranty Two year guarantee includes steel work, refractory lining, burners, regulators, hydraulic system and in summary all of pieces of the incinerator. During warranty period firm should maintain equipments and done PPM as per principle recommendation. If any spare part required during installation or PPM will be responsibility of the firm. Firm must send annual PPM schedule with installation report

INSTALLATION:-

Installation, lifting, civil and electric work is total responsibility of supplier.

Note: Before quoting bid supplier must visit the site.

Any other accessories required for completing the installation and to bring the units to operational state

is responsibility of supplier.

Optional Nil

Sr. No 5 Clinical Specialty Plant & Machinery

Page 71: RAWALPINDI INSTITUTE OF CARDIOLOGY, RAWAL ROAD, …eproc.punjab.gov.pk/AnnualProcurementPlan/annual... · 5 The Clinical Engineering Handbook 01 2016 6 BMET Study Guide (Preparing

Generic Name Air Curtain

Quantity 04

Clinical Purpose Use for paralyse patients lifting

TECHNICAL SPECIFICATIONS As per sample.

Accessories: Nil

Warranty: One year

Optional Nil

Sr. No 6 Clinical Specialty Plant & Machinery

Generic Name Feed water pump (Multi stage)

Quantity 01

Clinical Purpose Use for paralyse patients lifting

TECHNICAL SPECIFICATIONS Stain less steel. 2 horse power Single phase/ three phase US/Europe / Japan

Accessories: Nil

Warranty : One year

Optional Nil

Sr. No 7 Clinical Specialty Plant & Machinery

Generic Name Water pressure pump & other accessories

Quantity 02

Clinical Purpose To reduce the temperature effect from doors

TECHNICAL SPECIFICATIONS Stain less steel. 2 horse power Single phase/ three phase US/Europe / Japan

Page 72: RAWALPINDI INSTITUTE OF CARDIOLOGY, RAWAL ROAD, …eproc.punjab.gov.pk/AnnualProcurementPlan/annual... · 5 The Clinical Engineering Handbook 01 2016 6 BMET Study Guide (Preparing

Accessories: Nil

Warranty: One year

Optional Nil

Sr. No 8 Clinical Specialty Plant & Machinery

Generic Name Drinking water Filtration Plant Room of drinking water with chillers

Quantity 01

Clinical Purpose Used for drinking water

TECHNICAL SPECIFICATIONS PLANT DESIGN BASIS 1. FEED WATER PUMP Qty 01 Flow Rate 2 m3/ hr Max Pressure 30-40 psi 2800 rpm Line Size 1" Type Complete S.S 2. MULTI-MEDIA FILTER Qty 01 Head Valve Control System Manual Vessel Make & Origin Pentair Material FRP Lining Rubber / Fiber Vessel Size 13” x 54” Line Size (in /out) 1" Head Valve Type Manual Filtration Media Multiple Media, Quartz Gravel Sand Media Imported 3. GRANULAR ACTIVATED CARBON FILTER Qty 01 Head Valve Control System Manual Vessel Make & origin Pentair Material FRP Lining Rubber / Fiber Vessel Size 13” x 54” Line Size (in /out ) 1" Head Valve Type Manual Media Activated Carbon Carbon Media Imported 4. WATER SOFTENER Qty 01 Head Valve Control System Manual Make &origin Pentair Material FRP Lining Rubber / Fiber Vessel Size 13” x 54” Line Size (in /out) 1" Head Valve Type Manual Media Type Caution 5. MICRON FILTERS SYSTEM

Page 73: RAWALPINDI INSTITUTE OF CARDIOLOGY, RAWAL ROAD, …eproc.punjab.gov.pk/AnnualProcurementPlan/annual... · 5 The Clinical Engineering Handbook 01 2016 6 BMET Study Guide (Preparing

Water Flow Rat 2 m3/hr Max Filtration Rating 5/1 Micron Filtration Type Paper Plates Types / PPF Housing Material HDPE Filters Dimensions 20” No of Filters per bank 1 Nos 6. REVERSE OSMOSIS SYSTEM (RO) Quantity 01 Dimensions 4”x40” System Recovery 70% Rejection 97-99% 7. SKID STRUCTURE Compact Skid Structure Rust Proof S.S Law Space Occupation High Aesthetic Values 8. RO HIGH PRESSURE PUMP Quantity 01 Type Multistage Water Flow 2 m3 /hr Pump Head 150 PSI Max Power 220 V, I phase, 50Hz 9. RO MEMBRANE Quantity 02 No. Type 4x40” Model BW-30-40-40 10. MEMBRANE PRESSURE VESSELS Quantity 02 No. Material of Construction FRP Pressure Rating 200 psi Made Flourida 11. FLOW METER Quantity 2 Nos. Manufacture Blue White (USA) Range As required Type Analog 12. TDS METER Quantity 01 No Manufacture Imported Range 0-1000 micro- S/cm Type Digital 13. PRESSURE GAUGE Quantity 02 No Range 0-350 psi Size 63 mm Type Liquid Filled, Panel Mounting Material of Construction Full SS 316 14. LOW PRESSURE SWITCH Quantity 02 No Range 40-150 psi 15. HIGH PRESSURE PIPES AND FITTINGS All high pressure pipes and fittings will be high standard. 16. LOW PRESSURE PIPES AND FITTINGS All low pressure pipes and fitting will be UPVC, Sch 80 or equivalent. 17. MAIN SYSTEM CONTROL PANEL Automatic operation of the unit through Sami auto circuit.

Page 74: RAWALPINDI INSTITUTE OF CARDIOLOGY, RAWAL ROAD, …eproc.punjab.gov.pk/AnnualProcurementPlan/annual... · 5 The Clinical Engineering Handbook 01 2016 6 BMET Study Guide (Preparing

Safe Operation of High Pressure pump. Time delayed start up. Hand / auto operation of the system. 18. RAW WATER STORAGE TANK 200 GLS Qty 01 19. TREATED WATER STORAGE TANK 200GLS Qty 01 20. BOOSTER PUMP Qty 01 Flow Rate 1 m3 / hr Max Pressure 30-40 psi 2800 rmp Line Size 3/4” Type Complete S.S 21. WATER LEVEL SENSOR Qty 02 22. ULTRA VIOLET 36” SS Stock pump with tank for mixing of minerals. One big capacity Chiller. Room (as per requirement) Firm Must visit the side before quote.

Accessories: Standard accessories

Optional Nil

Warranty : Two year with all spare parts, during warranty period firm should maintain equipments and done PPM as per principle recommendation. If any spare part required during installation or PPM will be responsibility of the firm. Firm must send annual PPM schedule with installation report

INSTALLATION:-

Installation, lifting, civil and electric work is total responsibility of supplier. Note: Before quoting bid supplier must visit the site. Any other accessories required for completing the installation and to bring the units to operational state is responsibility of supplier.

Sr. No 9 Clinical Specialty Plant & Machinery

Generic Name Spot Welding Machine

Quantity 01

Clinical Purpose

TECHNICAL SPECIFICATIONS CE/ ISO approve spot welding machine. Capable to spot minimum size of cell. pneumatic type/ electrical In case of pneumatic type quote without compressor.

Accessories: Standard accessories

Page 75: RAWALPINDI INSTITUTE OF CARDIOLOGY, RAWAL ROAD, …eproc.punjab.gov.pk/AnnualProcurementPlan/annual... · 5 The Clinical Engineering Handbook 01 2016 6 BMET Study Guide (Preparing

Optional Nil

Sr. No 10 Clinical Specialty Plant & Machinery

Generic Name KVP Meter

Quantity 01

Clinical Purpose Used for calibration of X-Ray machine

TECHNICAL SPECIFICATIONS AS per sample approval

Accessories: Standard accessories

Optional Nil

Sr. No 11 Clinical Specialty Plant & Machinery

Generic Name MA Meter

Quantity 01

Clinical Purpose Used for calibration of X-Ray machine

TECHNICAL SPECIFICATIONS As per sample approval.

Accessories: Standard accessories

Optional Nil

Sr. No 12 Clinical Specialty Plant & Machinery

Generic Name Acrylic Sheet

Quantity 01

Clinical Purpose Used for calibration of X-Ray machine

TECHNICAL SPECIFICATIONS As per sample approval.

Accessories: Standard accessories

Optional Nil

Sr. No 13 Clinical Specialty Plant & Machinery

Generic Name Collimator Test Tool

Page 76: RAWALPINDI INSTITUTE OF CARDIOLOGY, RAWAL ROAD, …eproc.punjab.gov.pk/AnnualProcurementPlan/annual... · 5 The Clinical Engineering Handbook 01 2016 6 BMET Study Guide (Preparing

Quantity 01

Clinical Purpose Used for calibration of X-Ray machine

TECHNICAL SPECIFICATIONS As per sample approval.

Accessories: Standard accessories

Optional Nil

Sr. No 14 Clinical Specialty Plant & Machinery

Generic Name Beam Alignments Tool

Quantity 01

Clinical Purpose Used during service of radiology.

TECHNICAL SPECIFICATIONS As per sample approval.

Accessories: Standard accessories

Optional Nil

Sr. No 15 Clinical Specialty Plant & Machinery

Generic Name Sound Level Meter (Tube Head)

Quantity 01

Clinical Purpose Used for calibration of X-Ray tube head machine

TECHNICAL SPECIFICATIONS As per sample approval.

Accessories: Standard accessories

Optional Nil

Sr. No 16 Clinical Specialty Plant & Machinery

Generic Name DAM (Dose Area Product Meter)

Quantity 03

Clinical Purpose Used for calibration of X-Ray tube head machine

TECHNICAL SPECIFICATIONS As per sample approval.

Accessories: Standard accessories

Optional Nil

Page 77: RAWALPINDI INSTITUTE OF CARDIOLOGY, RAWAL ROAD, …eproc.punjab.gov.pk/AnnualProcurementPlan/annual... · 5 The Clinical Engineering Handbook 01 2016 6 BMET Study Guide (Preparing

Sr. No 17 Clinical Specialty Plant & Machinery

Generic Name Mobile X-Ray Radiation Protector

Quantity 02

Clinical Purpose Used for protection from X-Ray.

TECHNICAL SPECIFICATIONS As per sample approval.

Accessories: Standard accessories

Optional Nil

Sr. No 18 Clinical Specialty Plant & Machinery

Generic Name Lead Barrier

Quantity 02

Clinical Purpose Used for protection from X-Ray.

TECHNICAL SPECIFICATIONS As per sample approval.

Accessories: Standard accessories

Optional Nil

Page 78: RAWALPINDI INSTITUTE OF CARDIOLOGY, RAWAL ROAD, …eproc.punjab.gov.pk/AnnualProcurementPlan/annual... · 5 The Clinical Engineering Handbook 01 2016 6 BMET Study Guide (Preparing

DEMAND OF “REPAIR OF MEDICAL AND LAB EQUIPMENT” FOR TENDER 2016-17

Sr.No Item Required Qty Equipment/Specification Estimated

Cost

1 I.O board of special chemistry 01 For Access II backman culter 0.15 M

2 SPO2 probe 10 Compactable with cardiac monitor (Edan) 0.15 M

3 Defibrillator external paddles adult plates 10 Compactable with Innomed 360 B 1.5 M

4 Wheels of X-Ray machine 28 Primex HP32 (IBIS) 0.06 M

5 Tube Head of X-Ray machine 01 Primex HP32 (IBIS) 15 M

6 Expoyer Switch 06 Primex HP32 (IBIS) 0.3 M

7 PPM kit Fluoroscopy (Silicon Jacket,

Silicon Washer ) 10 set Zexira, Toshiba 0.1 M

8 Halogen lamp for CR system 01 Regius 110, Konica Menolta 0.03 M

9 Cooling fan of X-Ray agitator 04 Primex HP32 (IBIS) 0.12 M

10 ECG lead of ETT machine 02 For ETT machine cardiac since Quenton 0.16 M

11 Refrigerator over load relay and

capacitor 10+10 Compactable with Domatic refrigerator 0.2 M

12 O2 cell (Anesthesia) 20 Compactable with hyer Anesthesia machine 0.4 M

13 ABG’s machine electrode set 03 Easystat, Medica 0.6 M

14 Service kit item required for ABG’s machine.

01

For medica Easy state

a. Pump tube for Easy state. Qty : 03

b. Bubble detector for East state. Qty : 03

c. Valve module for Easy state. Qty : 01

d. Sampler for Easy state. Qty : 03

0.3 M

15 Flow sensor ventilator (Adult) 10 Compactable with Event C5 0.2 M

16 Batteries of different types 200

Used for UPS and different equipment back up.

As per sample. Type and quantity must conform

before quoting from bio medical department.

0.6 M

17 Defibrillator internal paddle adult 02 For Innomed 360 B 0.3 M

18 (ETT machine) BP cuff Adult 04 Compactable with suntech BP apparatus 0.08 M

19 (ETT machine) BP cuff Peads 02 Compactable with suntech BP apparatus 0.08 M

20 Laryngoscope (Bulb, cell, spring) 200 Fine quality as per sample approval 0.04 M

21 Syringe pump (Knobs) 50 As per sample approval 0.02 M

22 ECG leads of Holter monitor 10 Compactable with Burdick Vesion 5L 0.2 M

23 Pulse Ox meter SPO2 probe 10 Compactable with Innomed pulse ox meter as

per sample approval 0.12 M

24 ECG lead of balloon pump 02 Compactable with Data scope balloon pump 0.16 M

25 Air fitters of suction, nebulizer,

ventilator 200 As per sample approval 0.1 M

26 Power supply filter (ventilator,

Anesthesia) 200 As per sample approval 0.8 M

27 Fuse holder of syringe pump 100 As per sample approval 0.04 M

28 Power socket for syringe pump 50 As per sample approval 0.02 M

29 Power socket for docking station 50 As per sample approval 0.02 M

30 Blood warmer bags 05 set As per sample approval 0.8 M

31 Earth pad 04 Compactable with integra electrosurgical unit 0.2 M

32 Remote of OT table 02 For medifa 5 OT table 0.1 M

33 O2 cell of ventilator 10 Compactable with Event C5 0.15 M

34 NIBP hose connector 200 As per sample approval 0.04 M

35 Charger and motor for scrub unit 04+08 As per sample approval 0.1 M

36 TPM lead 20 Compactable with Medtronic TPM 0.8 M

37 3 lead ECG cable for defibrillator 30 Compactable with defibrillator 360 B 0.35 M

Page 79: RAWALPINDI INSTITUTE OF CARDIOLOGY, RAWAL ROAD, …eproc.punjab.gov.pk/AnnualProcurementPlan/annual... · 5 The Clinical Engineering Handbook 01 2016 6 BMET Study Guide (Preparing

38 BP cuff for cardiac monitor 200 Single lead as per sample approval 0.2 M

39 Service kit of anesthesia machine 02 For hyer Anesthesia machine 0.4 M

40 Service kit of ventilator 06 For E vent C5 1.0 M

41 Refrigerator door kit 05 Compactable with Domatic 0.3 M

42 Etco2 kit for cardiac monitor 15 Compatible with Nihon kohden BSM-6301K

monitors (as per approved sample) 0.5 M

Total 27.87 M

Page 80: RAWALPINDI INSTITUTE OF CARDIOLOGY, RAWAL ROAD, …eproc.punjab.gov.pk/AnnualProcurementPlan/annual... · 5 The Clinical Engineering Handbook 01 2016 6 BMET Study Guide (Preparing

DEMAND OF REPAIR OF PLANT & MACHINERY FOR TENDER 2016-17

SR.NO ITEM NAME QTY DESCRIPTION /SPECIFICATION ESTIMATED COST

CSSD

1 Door gasket of Auto

clave 05 For Auto clave MMM 0.25 M

2 Water filters 100 20 inch 5 micron as per sample approval. 0.02 M

3

complete service kit of

Reverse Osmosis

System (CSSD)

01

Must visit before Quoting, firm should maintain

TDS 2 to 10ppm with minimum 6L/min product

for one year, All accessories and spares including

membranes, media, resin, and pumps will be

responsibility of the firm.

0.4 M

Pathology

4

complete service kit of

Reverse Osmosis

System (Laboratory)

01

Must visit before Quoting, firm should maintain

TDS 0 to10 ppm with minimum 3L/min product

for one year, All accessories and spares including

membranes, media, resin, and pumps will be

responsibility of the firm.

0.4 M

Bio Gases

5 Vacuum pump kit 4

Make :Beacon medaes

Each kit contain following items

a. Oil can 5 litter

Part no: 2901 1831 10

Qty : 4

b. Kit-A after 1000 hour

Part no : 2901 2033 00

Qty : 4

c. Kiat-B after 2000 hour

Part no : 2901 2033 00 Qty : 4

d. Filter Elements

Part no : 2901 2042 00 Qty : 2

0.8 M

6 Air Compressor oil 02 Make : Atlas capco

Roto- inject fluid – 20 litter 0.02 M

7 Air Dryer Make : Atlas capco 0.02 M

Laundry

8 Door gas kit for

washer (Laundry) 03

For Electrolux

Model : W4600H

Part No: 4715631

0.15 M

9 Belt of flat work

Ironer (Complete set) 01 set

For Electrolux flat work iron

Model : IC 44825

Part no:

a. 77010306 (Qty: 12)

b. 77010002050 (Qty: 1)

0.06 M

10 Air Filter for washer 06

For Electrolux

Module : W4600H

Part no:4389601-20

0.05 M

11 Service kit of dryer 01 Make: Electrolux dryer 0.2 M

12 Rubber guide for

Washer 24

For Electrolux

Module : W4600H

part no:4320117-02

0.1 M

HVAC

13 HEPA filter 03 set

Used for OTs, ITC and CCU HVAC system

Efficiency : 99.99% @ 0.3 micron

Frame : galvanized steel

Size and Quantity as under

a. 505 x 505 x 292mm Qty : 12

b. 505 x 305 x 292mm Qty : 04

2.4 M

Page 81: RAWALPINDI INSTITUTE OF CARDIOLOGY, RAWAL ROAD, …eproc.punjab.gov.pk/AnnualProcurementPlan/annual... · 5 The Clinical Engineering Handbook 01 2016 6 BMET Study Guide (Preparing

c. 533 x 533 x 68 mm Qty : 32

d. 610 x 610 Qty : 8

e. 915 x 610 Qty : 24

14 Bag filter for HVAC 03 set

Imported quality should provide sample before

quoting.

Sizes :

a. 490 x592 x 534 x 5p(pockets) Qty : 36

b. 287 x592 x 534 x 3p(pockets) Qty : 16

c. 490 x 490 x 534 x 5p Qty : 16

d. 287 x 490 x 534 x 3p Qty : 12

0.24 M

15 Mash filter 02 set

Imported quality should provide sample before

quoting.

Sizes :

a. 490 x 592 x 48mm Qty : 116

b. 287 x 592 x 48mm Qty : 34

c. 490 x 490 48mm Qty : 96

d. 287 x 490 48mm Qty : 24

0.45

16 Descaling/service of

chillers 02

Kawasaki 630 ton unit

Type: ETEC-630AN7C.

Complete internal cleaning and maintenance of

chillers with chemicals and manual type,

All chemicals used during cleaning and Quality

test after maintenance should be responsibility

of the firm.

Should quote experience, well-known and

financially strong firms.

If any part required change will the responsibility

of firm

Firm should visit before quoting and check both

chillers

One year warranty including parts

1.6 M

17

Bearing for cooling

tower, pump motors

and other.

01 set

Bearing no and quantity is as under

a. 6213 Qty : 12

b. 6311 Qty : 12

c. 6212 Qty : 07

d. 6313 Qty : 07

e. 205 Qty : 06

0.08 M

18 Belts 01 set

Belt size and quantity is as under

a. A – 38 Qty : 144

b. A – 34 Qty : 48

c. A – 51 Qty : 48

d. A – 42 Qty : 24

e. A – 46 Qty : 24

f. 3HB x 2330 Qty : 03

0.54 M

Boiler

19 Annual maintenance

kit of Boiler (1.5 ton) 01

Make : by worth

Model : 7388 0.01 M

Total : 7.79 M

Page 82: RAWALPINDI INSTITUTE OF CARDIOLOGY, RAWAL ROAD, …eproc.punjab.gov.pk/AnnualProcurementPlan/annual... · 5 The Clinical Engineering Handbook 01 2016 6 BMET Study Guide (Preparing

Page 1 of 6

ELIGIBILITY CRITERIA

• Vendor should have Technical team of minimum 10 qualified professionals having minimum 3

certified professional for storage.

• Vendor must have 24x7 proper centralized helpdesk facilities for technical support. Details of

helpdesk must be attached with proposal.

• The project must be carried out by Certified Professional Team to ensure the successful

deployment. Vendor will provide the CVs of Project Team as well as the project manager for

the quoted project.

• The quoted prices should include professional services for the installation, configuration and

troubleshooting of the equipment under Tender.

• Support Accounts of RIC technical team will be created for direct interaction and opening of

Technical Support Cases with Principal. In this regards Vendor Party should facilitate the

process but the transparency with principal should remain.

• Necessary Trainings should be imparted to RIC team

• Total DICOM imaging modalities = 19 (Toshiba Angiography machine=3, Echo=7, US=4, X-Ray

CR system=2, Fluoroscopy=1, CT Scan=1, Gamma Camera=1)

Technical Specification for Radiology Information System/Cardiology Information System

Estimated Cost PkRS: (2,500,000.00 without All Taxes)

Key features of PACS

Integration with DICOM Modalities

Getting Modality wise work-lists

Integration with HMIS, Cardiology or RIS to receive DICOM Images

Accessible to Consultants and Doctors right on their Desktop or wherever required around the

globe.

Images compression

Efficient images storage and retrieval

Automatic Backup or Servers

Disaster recovery plan

Accessible via different DICOM Viewers

Accessible via Web Viewer through Internet

Add new modalities as needed

Analysis tools of images

Studies Advance search by (EMR, EHR, Patient Name or other parameters)

Section and User wise Viewer configuration and selection of preferred viewer

Export to and Import from Portable Media

Transfer Images to PACS or Workstation

Print Studies

Convert Studies to different portable formats

Send Studies through email (where possible)

Online Reporting

Page 83: RAWALPINDI INSTITUTE OF CARDIOLOGY, RAWAL ROAD, …eproc.punjab.gov.pk/AnnualProcurementPlan/annual... · 5 The Clinical Engineering Handbook 01 2016 6 BMET Study Guide (Preparing

Page 2 of 6

Send Reports through email

User Management and access control

Auto Routing / Forwarding studies based on selected modality types

Hanging Protocol

Comparison of Old and New Studies

Test status can be made active or deactivate.

Patient acknowledgement at radiology counter.

Technologist acknowledgement.

Different film sizes and no of films used for a test record for a patient entry screen.

Radiologist’s e u ith optio s of pe di g ork, pre ious reports / history, tra sfer of cases, history, patient notes, final sign.

Radiology reporting queue for transcription report writing

Radiologist’s appro al of report after reside t’s rite-up.

Addendum of verified report are available for radiologists.

Cancellation / un-verification of tests available

Radiology activity summary.

Reports are accessible and printable through we access.

All radiology equipment can be integrated to the radiology management system.

DICOM Viewer

o Clearcanvas OR equivalent for Radiologist

o RadiAnt or equivalent for Physician

RIS/CIS Software includes

o Setup machines

o Setup machines Worklist

o View images

o User wise DICOM Viewers

o Setup storage servers

o Enable compression

Transmissions and Sharing

User friendly front end application to manage PACS servers and data – all admin and user level

tasks.

Previous images downloading to workstations and machines

Powerful and speedy DICOM Viewers – friendly to the radiologists & clinicians

Image opening option on dual screen computers – or on any other computer through the

network. Clinicians can view images anywhere at any computer

Option to email images and report to anywhere

Complete troubleshoot training

DICOM Compression

Secure Image receiving based on Java Advanced Imaging (JAI)

Secure DICOM communication

Hanging Protocol via simple HMIS/RIS setup

Page 84: RAWALPINDI INSTITUTE OF CARDIOLOGY, RAWAL ROAD, …eproc.punjab.gov.pk/AnnualProcurementPlan/annual... · 5 The Clinical Engineering Handbook 01 2016 6 BMET Study Guide (Preparing

Page 3 of 6

Following are the standards of imaging formats supported.

Consultants, Cardiologists and Physicians, can view the cardiology static and Cine loop images at

their own desktop or handheld devices through PACS. PACS covers all imaging departments as

follows;

Cardiology

o Cath Lab, Echo, CT, Nuclear Cardiology, ECG, and ETT etc.

Radiology

o CT, CR, DR, NM, FL, MG, and US etc.

Nuclear Medicine/Cardiology

o Gamma Camera, Post-processing workstations

Miscellaneous Features

PACS Admin Panel PACS Administrator is a key role where PACS is deployed. PACS has complete

panel for PACS administrator panel to assist in all the activities and maintenance. Key functions in

1.2.840.10008.1.2 Implicit VR Endian: Default Transfer Syntax for DICOM

1.2.840.10008.1.2.1 Explicit VR Little Endian

1.2.840.10008.1.2.1.99 Deflated Explicit VR Little Endian

1.2.840.10008.1.2.2 Explicit VR Big Endian

Transfer Syntax UID Transfer Syntax name

1.2.840.10008.1.2.4.50 JPEG Baseline (Process 1):

Default Transfer Syntax for Lossy JPEG 8-bit Image Compression

1.2.840.10008.1.2.4.51 JPEG Baseline (Processes 2 & 4):

Default Transfer Syntax for Lossy JPEG 12-bit Image Compression

(Process 4 only)

1.2.840.10008.1.2.4.70 JPEG Lossless, Nonhierarchical, First- Order Prediction

(Processes 14 [Selection Value 1]):

Default Transfer Syntax for Lossless JPEG Image Compression

1.2.840.10008.1.2.4.80 JPEG-LS Lossless Image Compression

1.2.840.10008.1.2.4.81 JPEG-LS Lossy (Near- Lossless) Image Compression

1.2.840.10008.1.2.4.90 JPEG 2000 Image Compression (Lossless Only)

1.2.840.10008.1.2.4.91 JPEG 2000 Image Compression

1.2.840.10008.1.2.4.92 JPEG 2000 Part 2 Multicomponent Image Compression (Lossless

Only)

1.2.840.10008.1.2.4.93 JPEG 2000 Part 2 Multicomponent Image Compression

Transfer Syntax UID Transfer Syntax name

1.2.840.10008.1.2.4.94 JPIP Referenced

1.2.840.10008.1.2.4.95 JPIP Referenced Deflate

1.2.840.10008.1.2.5 RLE Lossless

1.2.840.10008.1.2.6.1 RFC 2557 MIME Encapsulation

Transfer Syntax UID Transfer Syntax name

1.2.840.10008.1.2.4.100 MPEG2 Main Profile Main Level

1.2.840.10008.1.2.4.102 MPEG-4 AVC/H.264 High Profile / Level 4.1

1.2.840.10008.1.2.4.103 MPEG-4 AVC/H.264 BD-compatible High Profile / Level 4.1

Page 85: RAWALPINDI INSTITUTE OF CARDIOLOGY, RAWAL ROAD, …eproc.punjab.gov.pk/AnnualProcurementPlan/annual... · 5 The Clinical Engineering Handbook 01 2016 6 BMET Study Guide (Preparing

Page 4 of 6

Admin panel are acquisition and integration of new imaging and information technologies in

seamless fashion

Critical functions as cases are maintained

Handle access to imaging quickly and efficiently as and where required

Policies, procedures, and practice related to PACS

Maintaining servers

Manage Archiving and Un-Archived cases

Routing troubleshooting

Administration and integration of new modalities and maintenance of existing

KPI’s

Vendor management

Training material and sessions

Network security, clustering, VPNs

Image Processing PACS allows to perform any image processing function at imaging data through

Interactive Desktop Imaging Viewer as;

Imaging comparison

Zoom in, Zoom out

Brightness and contrast

Windowing

Pencil tool

Flips

Rotations

Cine mode

Annotations

Length

Ellipse

Angle

Time-intensity curves (TIC)

Full-screen mode

External Media Import and Export PACS allows PACS Admin to import externally performed

studies into its storage – with retention periods.

Voice Recognition System PACS has its reporting tool which is integrated with voice recognition

system. It learns the radiologist and cardiologist accent and style of reporting with every passing

time to avoid errors in understanding.

Page 86: RAWALPINDI INSTITUTE OF CARDIOLOGY, RAWAL ROAD, …eproc.punjab.gov.pk/AnnualProcurementPlan/annual... · 5 The Clinical Engineering Handbook 01 2016 6 BMET Study Guide (Preparing

Page 5 of 6

Alerts System PACS has another unique feature which facilitates all related staff and engineers,

allowing them to perform their duties at high. It gives significant alerts of all normal and abnormal

events through SMS or Emails such as modality unavailability, modality calibration alerts, modality

network pinging, and communication alerts.

Support of JPEG Lossless, JPEG Lossless14, JPEG2000 Lossless, JPEGLS Lossless, JPEG Baseline

PACS Server

o DICOM Image Acquisition from Modality Machines. Communicate with registered

modality machine. Authentication of every client prior to communication association.

Support modality vendor workstation communication. Support All DICOM 3.0 class

UID’s for co u icatio . Support ECG-Wa elet, ECHO, A giography class UID’s. Se d previous studies to modality workstation on request. Communicate with all DICOM

enabled machine.

DICOM Work-list Manager

o Send scheduled patient information to modality machine. Communicate with

registered modalities machine. Authenticate modality prior to send patient scheduled

orders. Eliminate typographical mistakes and manual data entry. Support HL7.

PACS Study Routing Manager

o Automatically fetch previous studies for comparison. Support Distributed Environment.

Support multiple PACS storage servers. Client end Image Streaming. PACS Study Access

Audit Log

DICOM Lossless Compression

o Support All type of modality images (CT, MR, CR, DR, MG, FL, US, DX) including Digital

Subtraction Angiography (DSA). 70-85% compression ratio. Improve network

Performance. Save 70-80% storage cost. No proprietary compression format. Assure

image integrity and authenticity. DICOM Lossless Compression Detect image content

prior to compression.

DICOM Media –Writing

o Write auto-run CD of selected study for physician reference. Allow CD writing only to

authorize user.CD-Writing Audit Log. Export selected patient data on DICOM Media.

RIS-HMS-PACS HL7 Messaging Interface

o Support All types of HL7 Messages for information sharing:

Patient demographics

Clinical Observations

Diagnosis & Complaints

Encounters including registration, admission, discharge and transfer

Observation reporting including test results

o Client end Messaging Service

o Persists messages and guarantee secured message delivery.

o Event driven, and content-based routing.

o Ensure messages are routed in the sequence established by the sender

Diagnostic PACS Viewer

o Support All modalities images including ECG, Angiography, ECHO etc

Page 87: RAWALPINDI INSTITUTE OF CARDIOLOGY, RAWAL ROAD, …eproc.punjab.gov.pk/AnnualProcurementPlan/annual... · 5 The Clinical Engineering Handbook 01 2016 6 BMET Study Guide (Preparing

Page 6 of 6

o Cine playback of multi-frame sequences

o Multi-planar Reconstruction

o Window/Level contrast functions

o Distance, angle and density measurement

o Integrated with RIS application

o Real time Image streaming

o Open Multiple Studies for Comparison

CTSLECT - Thick Slice CT Study Extraction

o Save Storage to archive required CT study images.

o Improve Network Performance

o Physician Reference Images

o Configurable archived Images Slice Thickness

o Quickly Recall Study for Comparison

PACS Content Address Storage (CAS) Manager

o Guaranteed Content Authenticity

o Single Instance Storage

o Record-level Retention, Protection and Disposition

o Record Level Audit-ability

Page 88: RAWALPINDI INSTITUTE OF CARDIOLOGY, RAWAL ROAD, …eproc.punjab.gov.pk/AnnualProcurementPlan/annual... · 5 The Clinical Engineering Handbook 01 2016 6 BMET Study Guide (Preparing

Page 1 of 4

ELIGIBILITY CRITERIA

• Vendor must be an authorized dealer for the last 08 years of OEM/Principal for computers

• Vendor should have done at least 05 projects of similar nature and size.

• Vendor should be in similar business for at least 10 years.

• Vendor to provide the certificate of authorization along with the quotation on the name of

Executive Director RIC mention the name of representative of principal with his contact details

for verification.

• Vendor should have Technical team of minimum 10 plus one PMP certified PM if any. (3)

Qualified professionals having relevant certification. CV of technical staff should be provided

alo g ith erificatio Code ha i g ore tha 5 ears’ e perie ce i the rele a t field.

• Vendor must have 24x7 proper centralized helpdesk facilities for technical support. Details of

helpdesk must be attached with proposal.

• The project must be carried out by Certified Professional Team to ensure the successful

deployment. Vendor will provide the CVs of Project Team as well as the project manager for the

quoted project.

• The quoted prices should include professional services for the installation, configuration and

troubleshooting of the equipment under Tender.

• Support Accounts of RIC technical team will be created for direct interaction and opening of

Technical Support Cases with Principal. In this regards Vendor Party should facilitate the process

but the transparency with principal should remain.

• The items should be provided on Turnkey solution for whole project.

• VMWARE official training including exam for 2 individual including 1x for VCP-DCV, 1X for VCAP-

DCV Design exam.

TECHNICAL SPECIFICATION FOR REQUIRED I.T EQUIPMENT 2015-16

Computers QTY-25 (Estimated unit Price = Rs. 90,000)

Intel Core i5 6th Gen or Latest

4GB DDR4 RAM,

500GB 7200RPM Hard Drive

USB Key Board & Mouse

DVDRW

Wireless Connectivity 802.11n with Bluetooth

Chipset H110

RIC Logo in BIOS

18.5"LED Wide Screen Monitor

3 Years Warranty

Network Printers QTY-20 (Estimated unit Price = Rs. 50,000)

Resolution (black) Up to 4800 x 600 enhanced dpi or above

Print Speed Black 38 ppm or above

Processor 1200 Mhz or above

Memory 128 MB or above

Two sided Printing Automatic

First Page Out 5.7 sec or above

Page 89: RAWALPINDI INSTITUTE OF CARDIOLOGY, RAWAL ROAD, …eproc.punjab.gov.pk/AnnualProcurementPlan/annual... · 5 The Clinical Engineering Handbook 01 2016 6 BMET Study Guide (Preparing

Page 2 of 4

Monthly duty cycles Up to 80,000 pages or above

Connectivity 1 x Hi Speed USB 2.0, Host USB, Ethernet

10/100/1000

Print Technology Laser

Display 2-line backlit LCD graphic display

Paper trays, standard 2

Paper trays, maximum 3

Security SSL Security, SNMPv1, SNMPv2, SNMPv3,

IPv4, IPv6, DHCP

Warranty 01 Year

Desktop Printers QTY-15 (Estimated unit Price = Rs. 18,000)

Print Speed Black up to 19 ppm or above

Print Technology Laser

First page out as fast as 8.5 sec or above

Duplex Printing Manual

Connectivity USB

Print Quality 600x600x2 dpi or above

Warranty 01 Year

Digital Thermal Printer DICOM Enable QTY-3 (Estimated unit Price = Rs. 100,000)

Printing Method Direct thermal printing

Resolution 325 Dpi or above

Picture Elements 4096 x 1280 dots or above

Picture Area 320 x 100 mm or above

Paper Size 110 mm paper width or above

Printing Time 2 seconds per image

Gradations 8 bits or above

Flatbed Scanners QTY-10 (Estimated unit Price = Rs. 18,000)

Scanner Type Flatbed

Scan Resolution Optical up to 4800 dpi or above

Scan Resolution Hardware Up to 4800 x 9600 dpi or above

Enhanced Scanning Resolution Up to 999999 dpi or above

Scan Speed Up to 11 Sec

Bit Dept 48 bit or above

Scan size 8.5 x 11.7 in or above

Connectivity 1 x USB 2.0

Warranty 01 Year

Professional Mobile Scanners QTY-5 (Unit Price = Rs. 32,000)

Page 90: RAWALPINDI INSTITUTE OF CARDIOLOGY, RAWAL ROAD, …eproc.punjab.gov.pk/AnnualProcurementPlan/annual... · 5 The Clinical Engineering Handbook 01 2016 6 BMET Study Guide (Preparing

Page 3 of 4

Automatic Document feeder scan speed Up to 5 ppm/8 ipm or above

Bit Depth 48 Bit

Color Scanning Yes

Connectivity 1 x Hi Speed USB 2.0

Scan Resolution Optical 600 dpi or above

Scan Speed OCR A4 Upto 25 sec

Enlargement Range 10 to 2000% in 1% increments

Light 3 color LED

Scan Technology Contact Image Sensor

Media Size ADF Legal, Letter A4, A5, business cards etc

Power USB Powered

ANTIVIRUS SERVER BASED QTY-150 (Estimated unit Price = Rs. 5,100)

End Point Protection for 150 Users, Kaspersky internet security or equivalent

TABLETS QTY-10 (Estimated unit Price = Rs. 60,000)

Display 10.5 inches or above

Memory 16 GB, 3 GB RAM

CPU Quad-core 2.3 GHz

Resolution 2560 x 1600 pixels

OS Android OS Latest

Camera 8 MP | 2.1 MP

WLAN Wi-Fi 802.11 a/b/g/n/ac, dual-band, Wi-Fi Direct, hotspot

Brand Chinese brand not acceptable

WIFI Solution QTY-30 (Total Solution cost 5.5 Million)

Controller based Wifi Solution (support upto 256 APs) which should be compatible with

Juniper NAC

Ce tralized WLAN architecture ith thi Access Poi t a d ce tralized s itch/co trollers, and integrated network management

Wi-Fi Alliance Certification for 802.11 a/b/g/n/ac

Chassis and box N+1 redundancy with under 20 seconds failover time

Chassis and box 1+1 fast failover redundancy with sub-second failover time.

BYoD capable with extensive NMS visibility

Prioritize critical apps, or block unwanted ones, with integrated application traffic shaping

Intrusion detection and protection services, mesh routing with self-configuration and self-

optimization.

Automatically recognize the type (eg. Apple iOS) and model (eg. iPhone, iPad) of the mobile

device connecting to the network.

Directs/redirects traffic using GRE tunnels

Page 91: RAWALPINDI INSTITUTE OF CARDIOLOGY, RAWAL ROAD, …eproc.punjab.gov.pk/AnnualProcurementPlan/annual... · 5 The Clinical Engineering Handbook 01 2016 6 BMET Study Guide (Preparing

Page 4 of 4

Configuration and policy changes applied globally to all systems and APs from a single entry

point.

Access points should support 802.11 (h, r, k, v, w)

Integrates a stateful, layer 7 firewall

Supports unique web content and reputation policies

Support VLANs/ VLAN pools dynamically on a per-role basis

Support automatically blacklist clients based on authentication failures, policy violations,

DoS/MITM attacks

Centralized Encryption/De-encryption on switch/controller in data center.

Hardware Features:

Min 3 MIMO radios: 2.4 and 5 GHz, dual-band WIDS/WIPS

Min 2-stream 802.11n, up to 600 Mbps

802.3af PoE compatible with AC adapter availability

RF management with security

Stateful Layer 3-7 firewall

Identity-based group policies

Built-in antivirus scan

802.1x and native Active Directory integration

Air Marshal: real-time WIPS with forensics

WPA2/AES, WPA/TKIP

Support up to 256 AP or above

Support over 8000 number of concurrent connected wireless clients or above

Support up to 12 Gbps of stateful firewall throughput or above

Minimum 2 x 10Gbase-X (SFP+) ports

AppRF technology

up to 1.3Gbps wireless data rate

Support 802.11ac beamforming, 802.3az, spectrum analysis, advanced cellular filtering

Page 92: RAWALPINDI INSTITUTE OF CARDIOLOGY, RAWAL ROAD, …eproc.punjab.gov.pk/AnnualProcurementPlan/annual... · 5 The Clinical Engineering Handbook 01 2016 6 BMET Study Guide (Preparing

Page 1 of 4

ELIGIBILITY CRITERIA

• Vendor should have Technical team of minimum 06 Qualified professionals, 3 qualified

professionals having relevant certification. CV of technical staff should be provided along

with verification Code when required ha i g ore tha 5 ears’ e perie e i the rele a t field. Proof of concept is also required soon after the technical evaluation within short

period of time; date will be announced at the result of evaluation.

• ROs having less than 90% compliance will be rejected.

• Vendor must have 24x7 proper centralized helpdesk facilities for technical support.

Details of helpdesk must be attached with proposal.

• The project must be carried out by Professional Team to ensure the successful

deployment. Vendor will provide the CVs of Project Team as well as the project manager

for the quoted project.

• The quoted prices should include professional services for the installation, configuration

and troubleshooting of the equipment under Tender.

• Support Accounts of RIC technical team will be created for direct interaction and opening

of Technical Support Cases with Principal. In this regards Vendor Party should facilitate

the process but the transparency with principal should remain.

• Necessary Trainings should be imparted to RIC team Deployment time along with end user

certification is Max 3-4 Months.

• Vendor should have done at least 04 projects of similar nature and size.

• Vendor must be an authorized dealer for the last 3 years of OEM/Principal

• Vendor should be in similar business for at least 10 years.

• Vendor to provide the certificate of authorization along with the quotation on the name

of Executive Director RIC mention the name of representative of principal with his contact

details for verification.

• 1 Year warranty + replacement support.

• VMWARE official training including exam for 2 individuals for VCAP-DCV Deploy exam.

TECHNICAL SPECIFICATION FOR SOFTWARE

The purpose to automate the daily attendance of RIC staff is to provide efficient, effective,

responsive and transparent Time Attendance System to all the stakeholders in the institute.

The proposed system will facilitate the management at all levels to keep track of attendance,

leaves or absentees of the concerned staff.

The proposed system must be a web based standalone centralized Biometric Attendance

Management System. The proposed system must have comprised of biometric devices along

with centralized management software to communicate over network and all other necessary

equipment required for the complete functionalities.

For compliance, the proposed system provided by the ROs must fulfill the following:

Page 93: RAWALPINDI INSTITUTE OF CARDIOLOGY, RAWAL ROAD, …eproc.punjab.gov.pk/AnnualProcurementPlan/annual... · 5 The Clinical Engineering Handbook 01 2016 6 BMET Study Guide (Preparing

Page 2 of 4

TECHNICAL SPECIFICATION FOR CENTRALIZED BIOMETRIC ATTENDANCE MANAGEMENT

SYSTEM: QTY- 01 (Estimated Cost 950,000.00 without all taxes)

1. SOW (SCOPE OF WORK)

The Vendor must supply a T/A system that meets or exceeds the following specifications.

a. Dashboard

The system must be able to provide department wise Dashboard for higher

management in graphical form. Dashboard must contain the Drill down facility from

department to employees.

b. Organization Management Module

The system must be able to provide organizational structure at zones and

departments levels. The system must be able to provide different types of alerts to

each head of department.

c. Time Management Module

Creation of holiday calendar and different shifts timing facility must be provided by

the proposed system.

d. SMS Management Module

The system must be able to provide different types of SMS templates and SMS profiles.

e. Employees Management Module

The s ste ust e a le to register e plo ees’ fi ger pri ts alo g ith user id. The system must be able to record presence, leave and absence. It must include proper

leave approval mechanism. The system must encapsulate all the rules of business and

authority of the hierarchical positions.

f. Reports

The system must be able to provide all relevant reports and must have the flexibility

to adapt new reporting mechanisms. Different management layers must access their

relevant information. Provide a comprehensive reporting tool that allows managers

at different levels in the department to access reports of their HR resources. For higher

management, an easy to use management dash board to provide graphical reporting

of key indicators of the health department.

g. Employee Self Service

This allows each employee to log in to the system and check his/her own information.

Access to Personal Information System for their own data

Track Time/Attendance and leave requests

Apply for leave on line.

h. Leave Management System

Configure Leave and holiday time in multiple departments / hospitals etc

Customize work weeks based on departments.

Create Leave settings based on calendar or financial year.

Enter Leave restriction and other compliance rules.

Configure Leave settings based on employee status, job title, years of service or other

criteria, leave approval through management workflow, Enter Leave remainder rules

Page 94: RAWALPINDI INSTITUTE OF CARDIOLOGY, RAWAL ROAD, …eproc.punjab.gov.pk/AnnualProcurementPlan/annual... · 5 The Clinical Engineering Handbook 01 2016 6 BMET Study Guide (Preparing

Page 3 of 4

i. Ease of Use and security

The system must be user-friendly and secured so that only relevant information can

be accessed by the users assigned.

j. Integration

All the devices must be integrated through LAN and status of each device can be seen

through the management software.

Technical Architecture

a. Operating system

Following operating system can be to run the T/A system.

Microsoft Window Server 2012

b. Application & Database Platform

Application platform for T/A System should be on php, ASP.Net, MVC programming

Language and database must be MySql/SQL.

Page 95: RAWALPINDI INSTITUTE OF CARDIOLOGY, RAWAL ROAD, …eproc.punjab.gov.pk/AnnualProcurementPlan/annual... · 5 The Clinical Engineering Handbook 01 2016 6 BMET Study Guide (Preparing

Page 4 of 4

TECHNICAL SPECIFICATION FOR REQUIRED HARDWARE

Biometric Machine QTY-05

Type of Scanner Non coated optical scanner

Microprocessor 800 MHz

Memory 256 MB Flash Memory & 128 MB SD RAM

Storage

Fingerprint Templates > 7000

Face Detection >2000

Transactions > 100000

Enrolment and Verification

Methods Fingerprint (1:1, 1:N) and/or password

Fingerprint per user ID 2

Fingerprint placement Any angle

Verification time < 1 sec

Communication

Method TCP/IP, USB disk (Optional: RS232,

RS485,WiFi & GPRS)

Baud Rates 9600, 19200, 38400, 57600, 115200

Multimedia

Voice Yes

Display 3.0” olor s ree

Short messaging Yes

Page 96: RAWALPINDI INSTITUTE OF CARDIOLOGY, RAWAL ROAD, …eproc.punjab.gov.pk/AnnualProcurementPlan/annual... · 5 The Clinical Engineering Handbook 01 2016 6 BMET Study Guide (Preparing

Page 1 of 2

Technical Specification along with Requirements

Sr

No

Description Make and model Specifications Qty Est Cost

per unit

1 Toner Original HP 80 A For HP 400 Printer 30 10500/-

2 RAM 8 GB DDR3 1600 Laptop 05 9500/-

3 UPS Dry Batteries Liebert PSA 1000MT3-

230U

1500VA:12V 9AH

For PC Ups, Date of

Manufacturing 2016 onwards

with 1 year warranty

20 3000/-

4 UPS Dry Batteries Liebert PS2200RT-230 LEOCH DJW 12V 7.5 AH, Date

of Manufacturing 2016

onwards with 1 year warranty

50 3000/-

5 Dongles 1 G TP Link 20 2000/-

6 Cable Roles Schneider/3M Cat6 UL-Listed-EIA/TIA 23

AWG, 0.57mm pure copper

10 22000/-

7 SSD Drives 128 GB 10 11000/-

8 Portable Drives 1 TB 10 10000/-

9 Hard Disk Sata 500 GB For Systems 10 9500/-

10 Hard Disk Sata

2.5”

500 GB For Laptops/External

Drives

25 7000/-

11 Mouse A4Tech - 100 750/-

12 Key Board A4Tech - 50 1250/-

13 DVD Rom Sony 52x 50 2000/-

14 Power Distribution

Unit (PDU)

- 32A 03 45000/-

15 RJ 45 Connector

Box

3M/Baynet - 10 7000/-

19 Color Printer Epson L220 - 01

20 Tag Machine Roll Casio 9mm XR-9WE 20 800/-

21 USB HP 32 GB 10 2500/-

22 USB HP 64 GB 10 3500/-

23 VGA Splitter 4 Port 04 3000/-

24 Maint HP 3015

Printer

HP 3015 Printer Maintenance HP 3015 Printer

along with 1 year warranty

30

25 Q-Metic Printer Q-Metic Printer Q-Metic printer along with

touch panel

01 255000/-

26 Q-Metic Display

labels

Q-Metic Display Q-Metic Display sign boards

with prints

25 3000/-

27 Lamination

Machine

Lamination Machine Lamination Machine 03 7000/-

28 Color Printer Epson L455 Color Printer DICOM

Compatiable, Epson L455

02 45000/-

Demand of Repair & Maintenance of IT Equipment 2016-17

Page 97: RAWALPINDI INSTITUTE OF CARDIOLOGY, RAWAL ROAD, …eproc.punjab.gov.pk/AnnualProcurementPlan/annual... · 5 The Clinical Engineering Handbook 01 2016 6 BMET Study Guide (Preparing

Page 2 of 2

29 Printer Lexmark E260D/260DM - 02 17000/-

Note: Estimated prices are without all type of taxes.