29
Radio Frequency System SUS1 Instruction Manual HIABLASER TECHNOLOGY CO LTD

Radio Frequency System SUS1 Instruction Manual HIABLASER TECHNOLOGY CO LTD

Embed Size (px)

Citation preview

Page 1: Radio Frequency System SUS1 Instruction Manual HIABLASER TECHNOLOGY CO LTD

Radio Frequency SystemSUS1

Instruction Manual

HIABLASER TECHNOLOGY CO LTD

Page 2: Radio Frequency System SUS1 Instruction Manual HIABLASER TECHNOLOGY CO LTD

Deep heat generated

It is called diathermy(deep heating), which is the system providing treatment by generating heat from inside the human body.

Transformation into

biological energy

Electric energy input

Natural healingand immunity

increased

What is RF?

Principle of RF

Page 3: Radio Frequency System SUS1 Instruction Manual HIABLASER TECHNOLOGY CO LTD

Oscillation width is very short. Almost no ion movement of the

human body components. No electric-chemical reaction and electrolysis.

Solution to theDC current

shortcoming

Short period of pulsation No simulating of the sensory nerves;

motor nerves not to lead to the muscle contracted. (electric-acupuncture -effect with thousands of stimulation

without muscle fatigue or accumulated lactate)

Solution to the Low frequency

shortcoming

No piezoelectric  Applicable to eyes and head

Solution to the ultra-wave

shortcoming

+

+

Characteristics of RF

Page 4: Radio Frequency System SUS1 Instruction Manual HIABLASER TECHNOLOGY CO LTD

Increased the dermis

temperature and

cell functionality

Increased

blood circulation

Increased elasticity

of the

collagen fiber tissue

Remarkable reduction

in ankylosis

with the alleviation

of the pain

Relaxing the

muscular contracture

Promotion of the

chronic inflammatory

treatment

Promotes the wound

treatment

increase up to 45 ~ 60 in the hypodermi℃ s and muscular tissues.

Blood capillaries flow Increase by 4~5 times, Increase in metabolism materials purifying oxygen, nutritive materials, antibody,leukocyte and lymph circulation.

Increased elasticity by 5~10 times in muscle, ligament, articular capsule, and scar tissue. Maximum elasticity without damaging the tissues at 45-60 of local temperature of collagen.℃

Compared with the cold therapy, heat therapy reduces the ankylosis and inconvenience

Pain by the coronary heart disease : Alleviates the pain with the thermoelectric probe hyperemia. Increased by heating the regional pain or peripheral nerve, alleviating the pain in the muscle,ligament and tissue around the joint. Relaxing the muscular contracture by reducing the explosion of alpha motor nerve fiber

Increase in oxygen, nutritive, leukocyte and antibody by promoting the intravenous circulation and helping the absorption of the inflammatory fibroid

Helping the extension of the arteriole and blood capillaries to enhance the circulation on the skin and to promote the treatment according to the increased blood flow

Effects of RF

Page 5: Radio Frequency System SUS1 Instruction Manual HIABLASER TECHNOLOGY CO LTD

No contact allowed to electrolysis and plate

No use on the electric floor

No contact allowed to the customer

and administrator

Restricted on wearing the metal materials

The following customers may not useThe following customers may not use

1. In case of having the artificial heart machine

2. In case of having the metal materials in human body

(including the teeth retainer)

3. In case of the pregnant woman or possibility of the pregnancy

4. In case of the bleeding caused by the would or operation(except for the case the blood stops)

5. In case of the patient with high blood pressure

6. In case of the rupture of the blood vessel with hermorrhage and such possibility

7. In case of the patient either with acute inflammation, deep vein thrombosis, goiter, asthma,

cancer and so on.

8. In case of being at the period of menstruation

Cautions

Page 6: Radio Frequency System SUS1 Instruction Manual HIABLASER TECHNOLOGY CO LTD

Please let the entire part on the skin by using the proper size.

Please be careful not to cause the damage on the insulation coating to allow the high current to the body, and keep it in clean state after the use with 95% alcohol

ElectrodeElectrode Probes Probes

Stick it to the human body. In case the contact of the plate is not proper in theState allowing the current in the human body, you may have the injury by the heat from the plate.

Plate

Probe for Face & Head

Probe for Body

Put the smaller probe for face and head on the

right hole of the panel, with the red line

completely inside the hole.

Put the larger probe for body on the left hole of the panel, with the red line completely inside the hole

Brief introduction of the parts

Page 7: Radio Frequency System SUS1 Instruction Manual HIABLASER TECHNOLOGY CO LTD

Control Panel

TIME: Press “UP” or “DOWN” to adjust operation time. It ranges from 00-30 mins. Press one time to increase or decrease 5 mins.

MOME: Press “MODE” to select proper output for different treatment

area. MODE1 matches with 0.5M and it is for head treatment. MODE2 matches with 0.5M and it is for face treatment. MODE3 matches

with 0.3M and it is for body treatment. If Mode matches with the

wrong Frequency output and it doesn’t work.

FREQUENCY: Press “Frequency” to select 0.3M or 0.5M output.

START/STOP: Press “start/stop” button to change its working status.

P/LEVEL: When it is at start status, press “up” or “down” to adjust energy density. It ranges from 01 to 10. Recommend start from 02 and adjust until energy is proper.

Page 8: Radio Frequency System SUS1 Instruction Manual HIABLASER TECHNOLOGY CO LTD

1. Closely stick the plate under the skin and make sure it is fully contacted, otherwise, it will cause heat burning.

2. Turn on power switch on the right side of the machine.     

3. Choose FACE or BODY.

4. Select the electrode probe and put it in the right handpiece.     Choose the electrode that may be closely attached to your skin according to

the regional part

5. Apply message cream on the regional part of your skin.

6. Adjust the output.

How to Operate

Page 9: Radio Frequency System SUS1 Instruction Manual HIABLASER TECHNOLOGY CO LTD

Main EffectsMain Effects

◈ Skin Rejuvenating & Lifting Care

◈ Acne Care

◈ Special Eye Care, dark eye circle

◈ lymph drainage care

◈ Lip Care

CautionsCautions

◈ Since it may be dangerous with sudden blood flow to your head or face, if you raise it to the direction of the head, please make sure to lower it downward. 

◈ In case you have the facial dropsy, as it is caused by the congested body fluids, the dropsy becomes worsen when you treat it o

n the dropsy part. In this case, please treat first with ear, neck and axillary lymph node, t

o penetrate the blockage.

◈ Do not use it with high heat, but with slight heat.

◈ The lymph circulation control is the basis. Please apply it naturally by melting the cream.

FACE CARE

Page 10: Radio Frequency System SUS1 Instruction Manual HIABLASER TECHNOLOGY CO LTD

◈ Concerning the face treatment, first make the center line towards the right and left face section, and then manage from the center line to the direction of facial lymph point.

◈ If you manage it to the adverse direction of lymph (ear → nose, center line), it causes the flowing backward of lymph and yo

u will have the bloated face.

◈ Concerning the detailed parts (including nose, angled parts, rim of eye etc.), please finish with the small electrode probe.

◈ The administrator should not give the strong pressure on the

electrode probe.

◈ Softly and slowly rotate the electrode probe with slight heat (convenient temperature) rather than high heat. 

◈ When you move the electrode probe from the center to the outside, please do it slowly in the spiral way, and quickly return to the straight distance when getting back.

◈ Please closely attach your one hand without electrode on the customer's face or regional part, and then move it just like the massage in the same direction of the electrode at the same time.  At this time, it is the convenient temperature for the customer if you feel the moderate degree of heat in your palm.

◈ Never be exposed to cold wind such as washing the face in cold water, electric fan or air conditioner etc.

How to How to operateoperate

Page 11: Radio Frequency System SUS1 Instruction Manual HIABLASER TECHNOLOGY CO LTD

1. Proceed the cleansing. (Double washing face by using the hot water or steam)

2. Apply proper amount of cream.

3. Please separate the face region by the left and right, to softly control it with

moderate heat from the central part to the direction of lymph point. 

4. In case the electrode does not move well due to the mix of waste material and

    This is the process where the waste material drain out from the body, and repeat

to apply it several times until it feels soft.

5. The nose part or bent part should be controlled after changing to the small

electrode probe.

6. Please clean away cream from the electrode probe with warm water.

7. After that, finish with skin toner.

OperationOperation Technique Technique

◈ Control time : 10 min. ~ 15 min./one time

◈ Temperature:  40 ~ 42℃ (Slightly hot temperature)

◈ Control method       Do it in the same direction as the lymph circulation, adding more time on the pimple region, making the temperature at slightly hotter than that in the lymph circulation.      You can expect the improved state of the pimple traces with the ant- inflammatory effect reducing the heat status.     In case of the swollen pimple or pus, it seems worsen by the time of 3~4 application. However, since it is the infected region in the hair follicle rising over the skin surface, it is nothing to be worried about. As you proceed the treatment more than 4 times, you will be able to see the effect.  

How to How to operateoperate

PIMPLE CONTROL

Page 12: Radio Frequency System SUS1 Instruction Manual HIABLASER TECHNOLOGY CO LTD

1. Start the cleansing. (Double-washing face by using warm steam)

2. Using the cream on the entire face, please treat in the same

lymph direction as the pimple treatment. (10 minutes)

3. Intensive care with slight stronger temperature especially for the

region with much hypodermic fat.

4. After cream care, please clean it away from the electrode probe with warm water. or 95% alcohol.

It is in the same way as the general face care, and please care the protuberant part under eyes from inner to outer part in the sliding way. At this time, do not let cream in the eyes and apply the small amount of cream repeatedly.

.

It is in the same way as the general face care, and please mix and use the cream and activating cream as in the elasticity boost.  Slowly care and apply it in the light and sliding way, considering the direction of muscle and wrinkle. Especially for the wrinkle around the mouth, it is more effective to put the tongue from inside to outside.

FACE CARE

EYE CARE

WRINKLE CARE

Page 13: Radio Frequency System SUS1 Instruction Manual HIABLASER TECHNOLOGY CO LTD

1. Start the cleansing. (Double-washing face by using hot vapor) 2. Apply the cream. 3. Proceed the care in the same way as in pimple care. 4. Intensive care is needed especially for the severe discoloration. 5. At this time, in case of the discoloration around the eyes, please care it with the electrode in the soft sliding way from inner part to the outside because there is possibility of the wrinkle only if you put the strength on the electrode. 6. After the care, please clean the electrode probe with warm water

or 95% alcohol. 7. Please make sure to use the UV cream after finishing treatment.

◈ It is in the same way as the general face care, and please use and mix the cream and activating cream as face care

◈ Especially for the double chin, let the customer's chin pulled back and then care the regions from below the neck to the chin in the direction of the lymph.

◈ It is the important point of the care to recover the skin elasticity and to eliminate the unnecessary accumulated fat by activating the collagen fiber and elastin fiber and by increasing the blood flow.

DOUBLE CHIN CARE

FACE DISCOLORATION CARE

Page 14: Radio Frequency System SUS1 Instruction Manual HIABLASER TECHNOLOGY CO LTD

1. After letting the customer lie on one's stomach, the apply the electric-conduction cream entirely if the back region is wide and thick.

2. Provide the care by making spiral form from the below part of the backbone to the shoulder according to the center. 3. Provide the care by making small circle the scapula region from up to downward. 4. Care the trapezoid muscle region in right and left in turn. 5. In case of high blood pressure, do not care the back neck region. If not high blood pressure, it is possible to care the back neck and back part of the ears. 6. Clean away the cream carefully with hot towel. 7. For the hair-fallen scalp region, spray the scalp spray to the root region. 8. Using the electrode, slowly rotate it.

◈ Care Time : 10 min. ~ 15 min./1 time ◈ Temperature:  38 (moderate heat) ℃ ◈ The fallen hair may be caused by various reasons,

but the most cases are the stress or wrong shampoo habits leading to damaged scalp and narrowed pores.

◈ The priority purpose in this care is to open the passage from the back to the head.   Never provide this care to the customer who has experienced high pressure or cerebral hemorrhage, or such possibility of bleeding.

◈ After treatment, wash hair

How to How to operateoperate

OperationOperation technique technique

SCALP CARE

Page 15: Radio Frequency System SUS1 Instruction Manual HIABLASER TECHNOLOGY CO LTD

1. According to the usage, apply the cream from the part below the neck to the armpit and breast region.

2. With the arms raised, provide the care from the back side to the direction of the armpit center. 3. With body lying, provide the care from the part below the neck to the ymphocyte in the direction of armpit. 4. Starting from around the breast, and then gradually move to the nipple. 5. In case of the breast sliming, do not care the nipple region. 6. Massage toward outside, around the nipple. 7. After cleaning the cream with hot towel, and then apply the activating cream to provide the same care for 10 minutes.

◈ Delayed development and unbalanced breast stimulate the ovary strongly. At tis time, as the location of the ovary makes the influence in the contrary way of that of breast, the unbalanced breast stimulates the opposite ovary.

◈ In case of the drooped breast, please provide the intensive care the central part of the pectoralis major below the neck, pectoralis minor muscle, serratus muscle in the armpit and adjacent part around the pectoralis major muscle.

◈ You can expect the firming effect if the breast goes up together when the customer raises the arms above the head, standing Straight.

◈ To maximize the effect after care, please stimulate in the massaging way with other hand, according to the movement of the electrode.

How to How to operateoperate

BREAST CARE

Page 16: Radio Frequency System SUS1 Instruction Manual HIABLASER TECHNOLOGY CO LTD

1. Drink the warm water after care. 2. The body should never be exposed to cold shower or cold air. 3. After taking the sleep in the convenient state, clean away the cream with warm shower or hot towel. 4. You can expect faster effect, after hot water shower before care.

◈ Lymph care     1. Start from near the heart → to more distant direction     2. Face : back head → neck → face     3. Body : neck → arm pit → hand → groin part → back of the

knee → foot     4. Upper body : neck → arm pit → back → arm → palm

◈ Fat resolution      Strong stimulation and pressure control the tolerable maximum temperature.

◈ acupuncture point stimulation     Fix the electrode and stimulate for seconds on the acupuncture point region.

◈ Elasticity care      Softly stimulate the muscular direction.

How to How to operateoperate

OperationOperation technique technique

BODY CARE

Page 17: Radio Frequency System SUS1 Instruction Manual HIABLASER TECHNOLOGY CO LTD

① ②

① sacrum region      Stimulates the deep heat as in a way making small, middle and big circle.

② Pelvis region    Stimulates the deep heat as in a way making the spiral form to the outside of the pelvis.

③ sacrum region      Stimulates the deep heat as in a way making small, middle and big circle. ④ Pelvis region   Stimulates the deep heat as in a way making the spiral form to the outside of the pelvis.  

⑤ Massaging the scapula  Press the trapezoid muscle gently and promote the deep heat to the direction of axilla, according to the scapula line.

BACK CARE

Page 18: Radio Frequency System SUS1 Instruction Manual HIABLASER TECHNOLOGY CO LTD

⑥ Massaging the cervical vertebral By lowering the output to No. 4~5, promote the deep heat from the hairline at 2cm scalp to the No. 7 cervical vertebral            

⑦ Massaging the cervical vertebral Promotes the deep heat from the center of the cervical vertebral to the direction of the terminus

Page 19: Radio Frequency System SUS1 Instruction Manual HIABLASER TECHNOLOGY CO LTD

① Massaging the front groin part

② Massaging the foot Rotate the entire foot with  yong-cheon blood stream as the center in a massaging manner

③ Massaging the toes ④ Massaging the Achilles tendon

LEG CARE

Page 20: Radio Frequency System SUS1 Instruction Manual HIABLASER TECHNOLOGY CO LTD

⑤ Massaging the calf     Rolling the non-abdominal muscle in the spiral way, to promote the deep heat

⑥ Massaging the thighThe femoral region is to be divided into in and outside to draw it to thedirection of groin part

⑦ Massaging the butt ⑧ Finishing

thigh -> calf -> foot ⑦

Page 21: Radio Frequency System SUS1 Instruction Manual HIABLASER TECHNOLOGY CO LTD

① Massaging the navel center Promotes the deep heat in making the small, milddle and big circle from the navel center

② Crosswise massage     Promotes the deep heat in the Kimoon, Chakra, lower part and sacral blood Stream (diamond shape).

ABDOMEN CARE

Page 22: Radio Frequency System SUS1 Instruction Manual HIABLASER TECHNOLOGY CO LTD

③ Massaging the pelvis Promotes the deep heat, in rolling from the pelvis side of thepatient to the direction of the groin part.

④ Massaging the costa After scrubbing from inside the costa to the side to draw it to the direction of axilla.

Page 23: Radio Frequency System SUS1 Instruction Manual HIABLASER TECHNOLOGY CO LTD

③ Massaging the breast Massaging to the inner breast(pectoralis major muscle, pectoralis minor muscle) to the direction of axilla.

① sternum region   Scrubbing the sternum region in upward, downward and zig zag shape.

② Massaging the axilla   Rolling the inner part of the arms from the axilla.

BREAST CARE

Page 24: Radio Frequency System SUS1 Instruction Manual HIABLASER TECHNOLOGY CO LTD

④ Massaging the axilla Rolling to the inner side of the pectoralis major muscle breast for the finishing in axilla.

Breast sliming Same as above-mentioned ~ ① ④

⑤ Rolling from the outside to the inner side in the spiral form. ⑤

Page 25: Radio Frequency System SUS1 Instruction Manual HIABLASER TECHNOLOGY CO LTD

① Massaging axilla  In the axilla center, draw the inner part of the arm(biceps muscle).

② Massaging the triceps muscles  Massaging the lines of the triceps muscles and deltoid muscle to the direction of axilla.

Page 26: Radio Frequency System SUS1 Instruction Manual HIABLASER TECHNOLOGY CO LTD

③ Massaging the sides of the triceps muscles

④ Massaging the axilla

Page 27: Radio Frequency System SUS1 Instruction Manual HIABLASER TECHNOLOGY CO LTD

① Lymph massaging Promotes the deep heat by sufficiently massaging the profuntusand parotis.

② Lymph massaging  Scrubbing from the below part of the chin to the direction of sternocleidomastoid muscles and trapezoid muscle

③ Alleviating the wrinkles on the neck Alleviates the neck wrinkles except for the parts around the thyroid gland

FACE CARE

Page 28: Radio Frequency System SUS1 Instruction Manual HIABLASER TECHNOLOGY CO LTD

④ Promotes the deep heat by massaging the chin center in the spiral form

⑤ Arranging the chin line from below the chin to the lower part below the ears

⑥ Alleviates sides of the mouth in the triangular structure from the enter of the face.

⑦ Alleviates the chin-> sides of the mouth-> ears-> chin according to the face outline.

⑥ ⑦

Page 29: Radio Frequency System SUS1 Instruction Manual HIABLASER TECHNOLOGY CO LTD

⑧ Massages the outlines below the eyes, according to the cheekbone

⑨ Massages the side lines of the nose ⑩ Massages the parts around the

eyes in a circle form

⑪ Scrubbing from the eyebrow to the hair line direction.

⑫ Scrubbing from the center of the forehead to the outside direction.

⑬ Rolling according to the texture of the eyebrow

⑪⑫