17
RADIO FREQUENCY EMISSION ASSESSMENT AROUND TELECOMMUNICATION STRUCTURE IN PENANG

RADIO FREQUENCY EMISSION ASSESSMENT AROUND TELECOMMUNICATION STRUCTURE IN PENANG

Embed Size (px)

Citation preview

Page 1: RADIO FREQUENCY EMISSION ASSESSMENT AROUND TELECOMMUNICATION STRUCTURE IN PENANG

RADIO FREQUENCY EMISSION ASSESSMENT AROUND TELECOMMUNICATION STRUCTURE

IN PENANG

Page 2: RADIO FREQUENCY EMISSION ASSESSMENT AROUND TELECOMMUNICATION STRUCTURE IN PENANG

INTRODUCTION

OBJECTIVES

RF ASSESSMENT

RESULTS AND CONCLUSION

CONTENT

Page 3: RADIO FREQUENCY EMISSION ASSESSMENT AROUND TELECOMMUNICATION STRUCTURE IN PENANG

Introduction

• Malaysian Communication and Multimedia Commission (MCMC) has requested Malaysian Nuclear Agency to conduct a radiofrequency (RF) emission measurement around the mobile telephone base station (MTBS) and wireless broadband telecommunication structure around Penang.

• Assessment has been conducted the assessment work from 4th February

2015 to 12th February 2015.

• Ten sites were selected which represent different kind of structure: monopole, rooftop , structure on the ground and different operation of frequency band.

• covers mainland and island of Penang State.

Page 4: RADIO FREQUENCY EMISSION ASSESSMENT AROUND TELECOMMUNICATION STRUCTURE IN PENANG

Objective of project

• To determine the EMF source at selected telecommunications structures and locations

• To assess and analyze the RF emission level and compare to the EMF standard compliance by Malaysian Communication and Multimedia Commission (MCMC) and International Commission on Non-ionising Radiation Protection (ICNIRP).

• To simulate the RF emission pattern to ensure EMF compliance

Page 5: RADIO FREQUENCY EMISSION ASSESSMENT AROUND TELECOMMUNICATION STRUCTURE IN PENANG

LOCATION OF RF ASSESSMENTNo Site Date/Time

Telco repand contact no

1 Pasar Jelutong 4/2/2015 U MOBILE2 Bangunan Persatuan Bulan Sabit

Merah, Jalan Groove4/2/2015 UMOBILE

3 Klinik Mata OH, George Town 5/2/2015 CELCOM4 Kawasan stadium di Datuk Keramat,

George Town5/2/2015 UMOBILE

5 Hotel Rainbow Paradise 6/2/1015 CELCOM

6 Jalan Permatang Tok Gelam di Penaga / Jalan Teluk Air Tawar di Butterworth

10/2/2015 CELCOM

7 Kampung Benggali di Butterworth 10/2/2015 UMOBILE8 Taman Perwira, Simpang Ampat di

Seberang Perai11/2/2015 CELCOM

9 Jalan Rozhan/Jalan Perniagaan Alma di Bukit Mertajam

11/2/2015 CELCOM

10 Kota Permai, Bukit Mertajam 12/2/2015 UMOBILE

Page 6: RADIO FREQUENCY EMISSION ASSESSMENT AROUND TELECOMMUNICATION STRUCTURE IN PENANG

Based on standard protocol and procedures

recommended by Canadian Code 6, Malaysian

standard and IEEE.

Malaysian Communication and Multimedia Commission (MCMC) Mandatory Standards for Electromagnetic Field Emission from Radiocommunications infrastructure, Determination No. 1 of 2010 *Adopted ICNIRP recommendations and recognized by World Health Organisation (WHO)

SPECTRUM ANALYZER

ELECTROMAGNETIC PROBE

RADIOFREQUENCY (RF) EMISSION ASSESSMENT

STANDARD FOR PERMISSIBLE EXPOSURE LIMIT

MEASUREMENT PROTOCOL

Frequency (MHz) Electric Field

Strength (V/m)

Magnetic Field Strength (A/m)

Power Density (µW/cm2)

1 MHz – 10 MHz 87f0.5 0.073/f -

10 MHz- 400 MHz 28 0.073 200

400 MHz – 2GHz 1.375f 0.0037f0.5 f/2

2 GHz – 300 GHz 61 0.16 1000

Page 7: RADIO FREQUENCY EMISSION ASSESSMENT AROUND TELECOMMUNICATION STRUCTURE IN PENANG

PASAR JELUTONG, PENANG

SAMPLE OF RF MAPPING AT SELECTED SITE - MEASUREMENT POINT

Page 8: RADIO FREQUENCY EMISSION ASSESSMENT AROUND TELECOMMUNICATION STRUCTURE IN PENANG

Bangunan Persatuan Bulan Sabit Merah, Penang

SAMPLE OF RF MAPPING AT SELECTED SITE - MEASUREMENT POINT

Page 9: RADIO FREQUENCY EMISSION ASSESSMENT AROUND TELECOMMUNICATION STRUCTURE IN PENANG

PERMISSIBLE EXPOSURE LIMITS FOR MEMBERS OF PUBLIC

9

Frequency (MHz) Electric Field

Strength (V/m)

Magnetic Field Strength (A/m)

Power Density (µW/cm2)

1 MHz – 10 MHz 87f0.5 0.073/f -

10 MHz- 400 MHz 28 0.073 200

400 MHz – 2GHz 1.375f 0.0037f0.5 f/2

2 GHz – 300 GHz 61 0.16 1000

Notes: 1. Frequency (f) in MHz

* Mandatory standard Determination No.1 2010 – Malaysian Communication &Multimedia Commission (MCMC)*International Commission of Non-ionising Radiation Protection (ICNIRP)

Page 10: RADIO FREQUENCY EMISSION ASSESSMENT AROUND TELECOMMUNICATION STRUCTURE IN PENANG

RESULTS

Site

RF exposure(µWatts/cm2)

Permissible Exposure limit

(PEL)(µWatts/cm2)

Percentage compare to

exposure limit(%)

Network provider

Min Max

Pasar Jelutong 0.03 0.63 1000 0.063U Mobile

Bangunan Persatuan Bulan Sabit Merah 0.02 0.71 1000 0.071

U Mobile

Jalan Datuk Keramat 0.02 0.13 1000 0.013

U Mobile

Kampung Benggali 0.031 0.671 1000 0.067

U Mobile

Kota Permai 0.05 0.43 1000 0.043U Mobile

Oh Eye Clinic 0.11 0.66 450 0.146Celcom

Hotel Rainbow Paradise 0.02 0.14 450 0.031

Celcom

Taman Perwira 0.017 0.069 450 0.015Celcom

Jalan Teluk Air Tawar 0.045 0.328 450 0.073

Celcom

Jalan Perniagaan Alma 0.017 0.074 450 0.016

Celcom

Page 11: RADIO FREQUENCY EMISSION ASSESSMENT AROUND TELECOMMUNICATION STRUCTURE IN PENANG

RESULTS

Page 12: RADIO FREQUENCY EMISSION ASSESSMENT AROUND TELECOMMUNICATION STRUCTURE IN PENANG

Comparison of RF emission level by WiFi ,TV/radio and telecommunication system

Page 13: RADIO FREQUENCY EMISSION ASSESSMENT AROUND TELECOMMUNICATION STRUCTURE IN PENANG

RF emission level (µW/cm2)

0

300

1000

100

200450

Exposure limit for publicRF level assessed

•Telecomunication system•TV•Wifi

Page 14: RADIO FREQUENCY EMISSION ASSESSMENT AROUND TELECOMMUNICATION STRUCTURE IN PENANG

RF EXPOSURE LEVEL AT SAME HEIGHT WITH ANTENNA (SIDE VIEW)

SIMULATION

Page 15: RADIO FREQUENCY EMISSION ASSESSMENT AROUND TELECOMMUNICATION STRUCTURE IN PENANG

RF EXPOSURE LEVEL AT 1.5 METER FROM GROUND (SIDE VIEW)

RESULTS – COMPLY WITH PERMISSIBLE EXPOSURE LIMIT

Page 16: RADIO FREQUENCY EMISSION ASSESSMENT AROUND TELECOMMUNICATION STRUCTURE IN PENANG

CONCLUSION• The level of radiofrequency emission present at the selected area

concern are very low

• The emission are extremely well below the exposure limits stipulated by the MCMC and ICNIRP guidelines for members of the public. (< 1.0 % of the permissible exposure limit)

• Based on the findings of these measurements, we strongly believe that the presence of the RF emitted by the antennas installed on the telecommunication structure with the present loads and the background radiation would not lead to any significant radiation exposure received by members of the public living or working in the area of concern.

Page 17: RADIO FREQUENCY EMISSION ASSESSMENT AROUND TELECOMMUNICATION STRUCTURE IN PENANG

NUCLEAR MALAYSIA/RESULTS EMF ASSESSMENT-PENANG 2015