28
©Tokyo Electric Power Company Holdings. Inc. All Rights Reserved 0 Radiation concentrations measured at the multi-nuclide removal equipment (ALPS) outlet (as of June 30, 2019)

Radiation concentrations measured at the multi …...多核種除去設備(既設ALPS)【ストロンチウム(Sr)-90】 告示濃度限度(30Bq/L) 処理前 処理前(ND)※1

  • Upload
    others

  • View
    1

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Radiation concentrations measured at the multi …...多核種除去設備(既設ALPS)【ストロンチウム(Sr)-90】 告示濃度限度(30Bq/L) 処理前 処理前(ND)※1

©Tokyo Electric Power Company Holdings. Inc. All Rights Reserved 0

Radiation concentrations measuredat the multi-nuclide removal equipment (ALPS)

outlet (as of June 30, 2019)

Page 2: Radiation concentrations measured at the multi …...多核種除去設備(既設ALPS)【ストロンチウム(Sr)-90】 告示濃度限度(30Bq/L) 処理前 処理前(ND)※1

©Tokyo Electric Power Company Holdings. Inc. All Rights Reserved 1

※1 “ND” means that concentrations were below detectable limits.

0.01

0.1

1

10

100

1,000

10,000

100,000

1,000,000

2013/4/1 2013/11/15 2014/7/1 2015/2/14 2015/9/30 2016/5/15 2016/12/29 2017/8/14 2018/3/30 2018/11/13 2019/6/30

セシウム

(Cs)-

137濃度

(Bq/L

)

増設多核種除去設備(増設ALPS)【セシウム(Cs)-137】告示濃度限度(90Bq/L) 処理前処理前(ND)※1 設備出口A設備出口A(ND)※1 設備出口B設備出口B(ND)※1 設備出口C設備出口C(ND)※1

0.01

0.1

1

10

100

1,000

10,000

100,000

1,000,000

2013/4/1 2013/11/15 2014/7/1 2015/2/14 2015/9/30 2016/5/15 2016/12/29 2017/8/14 2018/3/30 2018/11/13 2019/6/30

セシウム

(Cs)-

137濃度

(Bq/L

)

多核種除去設備(既設ALPS) 【セシウム(Cs)-137】告示濃度限度(90Bq/L) 処理前処理前(ND)※1 設備出口A設備出口A(ND)※1 設備出口B設備出口B(ND)※1 設備出口C設備出口C(ND)※1

Existing ALPS(Cesium-137)

Cesiu

m-1

37 c

oncentr

ation(B

q/L

)

Cesiu

m-1

37 c

oncentr

ation(B

q/L

)

Additionally installed ALPS(Cesium-137)- - Limits for concentrations required by law(90Bq/L)

● Prior to treatment〇 Prior to treatment (ND) ※1■ Equipment outlet A□ Equipment outlet A (ND) ※1▲ Equipment outlet B△ Equipment outlet B (ND) ※1◆ Equipment outlet C◇ Equipment outlet C (ND) ※1

Radiation concentrations measured at the multi-nuclide removal equipment (ALPS) outlet

(Cesium-137 concentration)

- - Limits for concentrations required by law(90Bq/L)

● Prior to treatment〇 Prior to treatment (ND) ※1■ Equipment outlet A□ Equipment outlet A (ND) ※1▲ Equipment outlet B△ Equipment outlet B (ND) ※1◆ Equipment outlet C◇ Equipment outlet C (ND) ※1

Page 3: Radiation concentrations measured at the multi …...多核種除去設備(既設ALPS)【ストロンチウム(Sr)-90】 告示濃度限度(30Bq/L) 処理前 処理前(ND)※1

©Tokyo Electric Power Company Holdings. Inc. All Rights Reserved 2

0.01

0.1

1

10

100

1,000

10,000

100,000

1,000,000

2013/4/1 2013/11/15 2014/7/1 2015/2/14 2015/9/30 2016/5/15 2016/12/29 2017/8/14 2018/3/30 2018/11/13 2019/6/30

セシウム

(Cs)-

137濃度

(Bq/L

)

高性能多核種除去設備(高性能ALPS)【セシウム(Cs)-137】 告示濃度限度(90Bq/L) 処理前処理前(ND)※1 設備出口設備出口(ND)※1

- - Limits for concentrations required by law(90Bq/L)

● Prior to treatment〇 Prior to treatment (ND) ※1

■ Equipment outlet□ Equipment outlet (ND) ※1High-performance ALPS(Cesium-137)

Radiation concentrations measured at the multi-nuclide removal equipment (ALPS) outlet

(Cesium-137 concentration) C

esiu

m-1

37 c

oncentr

ation(B

q/L

)

※1 “ND” means that concentrations were below detectable limits.

Page 4: Radiation concentrations measured at the multi …...多核種除去設備(既設ALPS)【ストロンチウム(Sr)-90】 告示濃度限度(30Bq/L) 処理前 処理前(ND)※1

©Tokyo Electric Power Company Holdings. Inc. All Rights Reserved 3

0.01

0.1

1

10

100

1,000

10,000

100,000

1,000,000

2013/4/1 2013/11/15 2014/7/1 2015/2/14 2015/9/30 2016/5/15 2016/12/29 2017/8/14 2018/3/30 2018/11/13 2019/6/30

セシウム

(Cs)-

134濃度

(Bq/L

)

増設多核種除去設備(増設ALPS)【セシウム(Cs)-134】告示濃度限度(60Bq/L) 処理前処理前(ND)※1 設備出口A設備出口A(ND)※1 設備出口B設備出口B(ND)※1 設備出口C設備出口C(ND)※1

0.01

0.1

1

10

100

1,000

10,000

100,000

1,000,000

2013/4/1 2013/11/15 2014/7/1 2015/2/14 2015/9/30 2016/5/15 2016/12/29 2017/8/14 2018/3/30 2018/11/13 2019/6/30

セシウム

(Cs)-

134濃度

(Bq/L

)

多核種除去設備(既設ALPS)【セシウム(Cs)-134】告示濃度限度(60Bq/L) 処理前処理前(ND)※1 設備出口A設備出口A(ND)※1 設備出口B設備出口B(ND)※1 設備出口C設備出口C(ND)※1

Radiation concentrations measured at the multi-nuclide removal equipment (ALPS) outlet

(Cesium-134 concentration)

Existing ALPS(Cesium-134)

Additionally installed ALPS(Cesium-134)

Cesiu

m-1

34 c

oncentr

ation(B

q/L

)

Cesiu

m-1

34 c

oncentr

ation(B

q/L

)

- - Limits for concentrations required by law(60Bq/L)

● Prior to treatment〇 Prior to treatment (ND) ※1■ Equipment outlet A□ Equipment outlet A (ND) ※1▲ Equipment outlet B△ Equipment outlet B (ND) ※1◆ Equipment outlet C◇ Equipment outlet C (ND) ※1

- - Limits for concentrations required by law(60Bq/L)

● Prior to treatment〇 Prior to treatment (ND) ※1■ Equipment outlet A□ Equipment outlet A (ND) ※1▲ Equipment outlet B△ Equipment outlet B (ND) ※1◆ Equipment outlet C◇ Equipment outlet C (ND) ※1

※1 “ND” means that concentrations were below detectable limits.

Page 5: Radiation concentrations measured at the multi …...多核種除去設備(既設ALPS)【ストロンチウム(Sr)-90】 告示濃度限度(30Bq/L) 処理前 処理前(ND)※1

©Tokyo Electric Power Company Holdings. Inc. All Rights Reserved 4

0.01

0.1

1

10

100

1,000

10,000

100,000

1,000,000

2013/4/1 2013/11/15 2014/7/1 2015/2/14 2015/9/30 2016/5/15 2016/12/29 2017/8/14 2018/3/30 2018/11/13 2019/6/30

セシウム

(Cs)-

134濃度

(Bq/L

)

高性能多核種除去設備(高性能ALPS)【セシウム(Cs)-134】 告示濃度限度(60Bq/L) 処理前処理前(ND)※1 設備出口設備出口(ND)※1

Radiation concentrations measured at the multi-nuclide removal equipment (ALPS) outlet

(Cesium-134 concentration)

High-performance ALPS(Cesium-134)C

esiu

m-1

34 c

oncentr

ation(B

q/L

)

- - Limits for concentrations required by law(60Bq/L)

● Prior to treatment〇 Prior to treatment (ND) ※1

■ Equipment outlet□ Equipment outlet (ND) ※1

※1 “ND” means that concentrations were below detectable limits.

Page 6: Radiation concentrations measured at the multi …...多核種除去設備(既設ALPS)【ストロンチウム(Sr)-90】 告示濃度限度(30Bq/L) 処理前 処理前(ND)※1

©Tokyo Electric Power Company Holdings. Inc. All Rights Reserved 5

0.01

0.1

1

10

100

1,000

10,000

100,000

1,000,000

10,000,000

100,000,000

1,000,000,000

10,000,000,000

2013/4/1 2013/11/15 2014/7/1 2015/2/14 2015/9/30 2016/5/15 2016/12/29 2017/8/14 2018/3/30 2018/11/13 2019/6/30ストロンチウム

(Sr)

-90濃度

(Bq/L

)

増設多核種除去設備(増設ALPS)【ストロンチウム(Sr)-90】 告示濃度限度(30Bq/L) 処理前処理前(ND)※1 設備出口A設備出口A(ND)※1 設備出口B設備出口B(ND)※1 設備出口C設備出口C(ND)※1

0.01

0.1

1

10

100

1,000

10,000

100,000

1,000,000

10,000,000

100,000,000

1,000,000,000

10,000,000,000

2013/4/1 2013/11/15 2014/7/1 2015/2/14 2015/9/30 2016/5/15 2016/12/29 2017/8/14 2018/3/30 2018/11/13 2019/6/30ストロンチウム

(Sr)

-90濃度

(Bq/L

)

多核種除去設備(既設ALPS)【ストロンチウム(Sr)-90】告示濃度限度(30Bq/L) 処理前処理前(ND)※1 設備出口A設備出口A(ND)※1 設備出口B設備出口B(ND)※1 設備出口C設備出口C(ND)※1

Radiation concentrations measured at the multi-nuclide removal equipment (ALPS) outlet

(Strontium-90 concentration)

Existing ALPS(Strontium-90)

Additionally installed ALPS(Strontium-90)

Str

ontium

-90 c

oncentr

ation(B

q/L

)

Str

ontium

-90 c

oncentr

ation(B

q/L

)

- - Limits for concentrations required by law(30Bq/L)

● Prior to treatment〇 Prior to treatment (ND) ※1■ Equipment outlet A□ Equipment outlet A (ND) ※1▲ Equipment outlet B△ Equipment outlet B (ND) ※1◆ Equipment outlet C◇ Equipment outlet C (ND) ※1

- - Limits for concentrations required by law(30Bq/L)

● Prior to treatment〇 Prior to treatment (ND) ※1■ Equipment outlet A□ Equipment outlet A (ND) ※1▲ Equipment outlet B△ Equipment outlet B (ND) ※1◆ Equipment outlet C◇ Equipment outlet C (ND) ※1

※1 “ND” means that concentrations were below detectable limits.

Page 7: Radiation concentrations measured at the multi …...多核種除去設備(既設ALPS)【ストロンチウム(Sr)-90】 告示濃度限度(30Bq/L) 処理前 処理前(ND)※1

©Tokyo Electric Power Company Holdings. Inc. All Rights Reserved 6

0.01

0.1

1

10

100

1,000

10,000

100,000

1,000,000

10,000,000

100,000,000

1,000,000,000

10,000,000,000

2013/4/1 2013/11/15 2014/7/1 2015/2/14 2015/9/30 2016/5/15 2016/12/29 2017/8/14 2018/3/30 2018/11/13 2019/6/30ストロンチウム

(Sr)

-90濃度

(Bq/L

)高性能多核種除去設備(高性能ALPS)【ストロンチウム(Sr)-90】 告示濃度限度(30Bq/L) 処理前

処理前(ND)※1 設備出口設備出口(ND)※1

Radiation concentrations measured at the multi-nuclide removal equipment (ALPS) outlet

(Strontium-90 concentration)

High-performance ALPS(Strontium-90)

Str

ontium

-90 c

oncentr

ation(B

q/L

)

- - Limits for concentrations required by law(30Bq/L)

● Prior to treatment〇 Prior to treatment (ND) ※1

■ Equipment outlet□ Equipment outlet (ND) ※1

※1 “ND” means that concentrations were below detectable limits.

Page 8: Radiation concentrations measured at the multi …...多核種除去設備(既設ALPS)【ストロンチウム(Sr)-90】 告示濃度限度(30Bq/L) 処理前 処理前(ND)※1

©Tokyo Electric Power Company Holdings. Inc. All Rights Reserved 7

0.01

0.1

1

10

100

1,000

10,000

100,000

2013/4/1 2013/11/15 2014/7/1 2015/2/14 2015/9/30 2016/5/15 2016/12/29 2017/8/14 2018/3/30 2018/11/13 2019/6/30

コバルト

(Co)-

60濃度

(Bq/L

)

増設多核種除去設備(増設ALPS)【コバルト(Co)-60】告示濃度限度(200Bq/L) 処理前処理前(ND)※1 設備出口A設備出口A(ND)※1 設備出口B設備出口B(ND)※1 設備出口C設備出口C(ND)※1

0.01

0.1

1

10

100

1,000

10,000

100,000

2013/4/1 2013/11/15 2014/7/1 2015/2/14 2015/9/30 2016/5/15 2016/12/29 2017/8/14 2018/3/30 2018/11/13 2019/6/30

コバルト

(Co)-

60濃度

(Bq/L

)

多核種除去設備(既設ALPS)【コバルト(Co)-60】告示濃度限度(200Bq/L) 処理前処理前(ND)※1 設備出口A設備出口A(ND)※1 設備出口B設備出口B(ND)※1 設備出口C設備出口C(ND)※1

Radiation concentrations measured at the multi-nuclide removal equipment (ALPS) outlet

(Cobalt-60 concentration)

Existing ALPS(Cobalt-60)

Additionally installed ALPS(Cobalt-60)

Cobalt-6

0 c

oncentr

ation(B

q/L

)

Cobalt-6

0 c

oncentr

ation(B

q/L

)

- - Limits for concentrations required by law(200Bq/L)

● Prior to treatment〇 Prior to treatment (ND) ※1■ Equipment outlet A□ Equipment outlet A (ND) ※1▲ Equipment outlet B△ Equipment outlet B (ND) ※1◆ Equipment outlet C◇ Equipment outlet C (ND) ※1

- - Limits for concentrations required by law(200Bq/L)

● Prior to treatment〇 Prior to treatment (ND) ※1■ Equipment outlet A□ Equipment outlet A (ND) ※1▲ Equipment outlet B△ Equipment outlet B (ND) ※1◆ Equipment outlet C◇ Equipment outlet C (ND) ※1

※1 “ND” means that concentrations were below detectable limits.

Page 9: Radiation concentrations measured at the multi …...多核種除去設備(既設ALPS)【ストロンチウム(Sr)-90】 告示濃度限度(30Bq/L) 処理前 処理前(ND)※1

©Tokyo Electric Power Company Holdings. Inc. All Rights Reserved 8

0.01

0.1

1

10

100

1,000

10,000

100,000

2013/4/1 2013/11/15 2014/7/1 2015/2/14 2015/9/30 2016/5/15 2016/12/29 2017/8/14 2018/3/30 2018/11/13 2019/6/30

コバルト

(Co)-

60濃度

(Bq/L

)

高性能多核種除去設備(高性能ALPS)【コバルト(Co)-60】 告示濃度限度(200Bq/L) 処理前処理前(ND)※1 設備出口設備出口(ND)※1

Radiation concentrations measured at the multi-nuclide removal equipment (ALPS) outlet

(Cobalt-60 concentration)

High-performance ALPS(Cobalt-60)C

obalt-6

0 c

oncentr

ation(B

q/L

)

- - Limits for concentrations required by law(200Bq/L)

● Prior to treatment〇 Prior to treatment (ND) ※1

■ Equipment outlet□ Equipment outlet (ND) ※1

※1 “ND” means that concentrations were below detectable limits.

Page 10: Radiation concentrations measured at the multi …...多核種除去設備(既設ALPS)【ストロンチウム(Sr)-90】 告示濃度限度(30Bq/L) 処理前 処理前(ND)※1

©Tokyo Electric Power Company Holdings. Inc. All Rights Reserved 9

0.1

1

10

100

1,000

10,000

100,000

1,000,000

2013/4/1 2013/11/15 2014/7/1 2015/2/14 2015/9/30 2016/5/15 2016/12/29 2017/8/14 2018/3/30 2018/11/13 2019/6/30

アンチモン

(Sb)-

125濃度

(Bq/L

)

増設多核種除去設備(増設ALPS)【アンチモン(Sb)-125】告示濃度限度(800Bq/L) 処理前処理前(ND)※1 設備出口A設備出口A(ND)※1 設備出口B設備出口B(ND)※1 設備出口C設備出口C(ND)※1

0.1

1

10

100

1,000

10,000

100,000

1,000,000

2013/4/1 2013/11/15 2014/7/1 2015/2/14 2015/9/30 2016/5/15 2016/12/29 2017/8/14 2018/3/30 2018/11/13 2019/6/30

アンチモン

(Sb)-

125濃度

(Bq/L

)

多核種除去設備(既設ALPS) 【アンチモン(Sb)-125】告示濃度限度(800Bq/L) 処理前処理前(ND)※1 設備出口A設備出口A(ND)※1 設備出口B設備出口B(ND)※1 設備出口C設備出口C(ND)※1

Radiation concentrations measured at the multi-nuclide removal equipment (ALPS) outlet

(Antimony-125 concentration)

Existing ALPS(Antimony-125)

Additionally installed ALPS(Antimony-125)

Antim

ony-1

25 c

oncentr

ation(B

q/L

)

Antim

ony-1

25 c

oncentr

ation(B

q/L

)

- - Limits for concentrations required by law(800Bq/L)

● Prior to treatment〇 Prior to treatment (ND) ※1■ Equipment outlet A□ Equipment outlet A (ND) ※1▲ Equipment outlet B△ Equipment outlet B (ND) ※1◆ Equipment outlet C◇ Equipment outlet C (ND) ※1

- - Limits for concentrations required by law(800Bq/L)

● Prior to treatment〇 Prior to treatment (ND) ※1■ Equipment outlet A□ Equipment outlet A (ND) ※1▲ Equipment outlet B△ Equipment outlet B (ND) ※1◆ Equipment outlet C◇ Equipment outlet C (ND) ※1

※1 “ND” means that concentrations were below detectable limits.

Page 11: Radiation concentrations measured at the multi …...多核種除去設備(既設ALPS)【ストロンチウム(Sr)-90】 告示濃度限度(30Bq/L) 処理前 処理前(ND)※1

©Tokyo Electric Power Company Holdings. Inc. All Rights Reserved 10

0.1

1

10

100

1,000

10,000

100,000

1,000,000

2013/4/1 2013/11/15 2014/7/1 2015/2/14 2015/9/30 2016/5/15 2016/12/29 2017/8/14 2018/3/30 2018/11/13 2019/6/30

アンチモン

(Sb)-

125濃度

(Bq/L

)

高性能多核種除去設備(高性能ALPS)【アンチモン(Sb)-125】 告示濃度限度(800Bq/L) 処理前処理前(ND)※1 設備出口設備出口(ND)※1

Radiation concentrations measured at the multi-nuclide removal equipment (ALPS) outlet

(Antimony-125 concentration)

High-performance ALPS(Antimony-125)- - Limits for concentrations required by law(800Bq/L)

● Prior to treatment〇 Prior to treatment (ND) ※1

■ Equipment outlet□ Equipment outlet (ND) ※1

※1 “ND” means that concentrations were below detectable limits.

Antim

ony-1

25 c

oncentr

ation(B

q/L

)

Page 12: Radiation concentrations measured at the multi …...多核種除去設備(既設ALPS)【ストロンチウム(Sr)-90】 告示濃度限度(30Bq/L) 処理前 処理前(ND)※1

©Tokyo Electric Power Company Holdings. Inc. All Rights Reserved 11

0.1

1

10

100

1,000

10,000

100,000

1,000,000

2013/4/1 2013/11/15 2014/7/1 2015/2/14 2015/9/30 2016/5/15 2016/12/29 2017/8/14 2018/3/30 2018/11/13 2019/6/30

ルテニウム

(Ru)-

106濃度

(Bq/L

)

増設多核種除去設備(増設ALPS)【ルテニウム(Ru)-106】告示濃度限度(100Bq/L) 処理前処理前(ND)※1 設備出口A設備出口A(ND)※1 設備出口B設備出口B(ND)※1 設備出口C設備出口C(ND)※1

0.1

1

10

100

1,000

10,000

100,000

1,000,000

2013/4/1 2013/11/15 2014/7/1 2015/2/14 2015/9/30 2016/5/15 2016/12/29 2017/8/14 2018/3/30 2018/11/13 2019/6/30

ルテニウム

(Ru)-

106濃度

(Bq/L

)

多核種除去設備(既設ALPS)【ルテニウム(Ru)-106】告示濃度限度(100Bq/L) 処理前処理前(ND)※1 設備出口A設備出口A(ND)※1 設備出口B設備出口B(ND)※1 設備出口C設備出口C(ND)※1

Radiation concentrations measured at the multi-nuclide removal equipment (ALPS) outlet

(Ruthenium-106 concentration)

Existing ALPS(Ruthenium-106)R

uth

eniu

m-1

06

concentr

ation(B

q/L

)

Ruth

eniu

m-1

06 c

oncentr

ation(B

q/L

)

- - Limits for concentrations required by law(100Bq/L)

● Prior to treatment〇 Prior to treatment (ND) ※1■ Equipment outlet A□ Equipment outlet A (ND) ※1▲ Equipment outlet B△ Equipment outlet B (ND) ※1◆ Equipment outlet C◇ Equipment outlet C (ND) ※1

- - Limits for concentrations required by law(100Bq/L)

● Prior to treatment〇 Prior to treatment (ND) ※1■ Equipment outlet A□ Equipment outlet A (ND) ※1▲ Equipment outlet B△ Equipment outlet B (ND) ※1◆ Equipment outlet C◇ Equipment outlet C (ND) ※1

Additionally installed ALPS(Ruthenium-106)

※1 “ND” means that concentrations were below detectable limits.

Page 13: Radiation concentrations measured at the multi …...多核種除去設備(既設ALPS)【ストロンチウム(Sr)-90】 告示濃度限度(30Bq/L) 処理前 処理前(ND)※1

©Tokyo Electric Power Company Holdings. Inc. All Rights Reserved 12

0.1

1

10

100

1,000

10,000

100,000

1,000,000

2013/4/1 2013/11/15 2014/7/1 2015/2/14 2015/9/30 2016/5/15 2016/12/29 2017/8/14 2018/3/30 2018/11/13 2019/6/30

ルテニウム

(Ru)-

106濃度

(Bq/L

)

高性能多核種除去設備(高性能ALPS) 【ルテニウム(Ru)-106】 告示濃度限度(100Bq/L) 処理前処理前(ND)※1 設備出口設備出口(ND)※1

Radiation concentrations measured at the multi-nuclide removal equipment (ALPS) outlet

(Ruthenium-106 concentration)

High-performance ALPS(Ruthenium-106) - - Limits for concentrations required by law(100Bq/L)

● Prior to treatment〇 Prior to treatment (ND) ※1

■ Equipment outlet□ Equipment outlet (ND) ※1

Ruth

eniu

m-1

06

concentr

ation(B

q/L

)

※1 “ND” means that concentrations were below detectable limits.

Page 14: Radiation concentrations measured at the multi …...多核種除去設備(既設ALPS)【ストロンチウム(Sr)-90】 告示濃度限度(30Bq/L) 処理前 処理前(ND)※1

©Tokyo Electric Power Company Holdings. Inc. All Rights Reserved 13

0.01

0.1

1

10

100

1,000

10,000

2013/4/1 2013/11/15 2014/7/1 2015/2/14 2015/9/30 2016/5/15 2016/12/29 2017/8/14 2018/3/30 2018/11/13 2019/6/30

ヨウ素

(I)-

129濃度

(Bq/L

)

増設多核種除去設備(増設ALPS)【ヨウ素(I)-129】告示濃度限度(9Bq/L) 処理前処理前(ND)※1 設備出口A設備出口A(ND)※1 設備出口B設備出口B(ND)※1 設備出口C設備出口C(ND)※1

0.01

0.1

1

10

100

1,000

10,000

2013/4/1 2013/11/15 2014/7/1 2015/2/14 2015/9/30 2016/5/15 2016/12/29 2017/8/14 2018/3/30 2018/11/13 2019/6/30

ヨウ素

(I)-

129濃度

(Bq/L

)多核種除去設備(既設ALPS)【ヨウ素(I)-129】

告示濃度限度(9Bq/L) 処理前処理前(ND)※1 設備出口A設備出口A(ND)※1 設備出口B設備出口B(ND)※1 設備出口C設備出口C(ND)※1

Radiation concentrations measured at the multi-nuclide removal equipment (ALPS) outlet

(Iodine-129 concentration)

Additionally installed ALPS(Iodine-129)

Existing ALPS(Iodine-129)Io

din

e-1

29 c

oncentr

ation(B

q/L

)

Iodin

e-1

29 c

oncentr

ation(B

q/L

)

- - Limits for concentrations required by law(9Bq/L)

● Prior to treatment〇 Prior to treatment (ND) ※1■ Equipment outlet A□ Equipment outlet A (ND) ※1▲ Equipment outlet B△ Equipment outlet B (ND) ※1◆ Equipment outlet C◇ Equipment outlet C (ND) ※1

- - Limits for concentrations required by law(9Bq/L)

● Prior to treatment〇 Prior to treatment (ND) ※1■ Equipment outlet A□ Equipment outlet A (ND) ※1▲ Equipment outlet B△ Equipment outlet B (ND) ※1◆ Equipment outlet C◇ Equipment outlet C (ND) ※1

※1 “ND” means that concentrations were below detectable limits.

Page 15: Radiation concentrations measured at the multi …...多核種除去設備(既設ALPS)【ストロンチウム(Sr)-90】 告示濃度限度(30Bq/L) 処理前 処理前(ND)※1

©Tokyo Electric Power Company Holdings. Inc. All Rights Reserved 14

0.01

0.1

1

10

100

1,000

10,000

2013/4/1 2013/11/15 2014/7/1 2015/2/14 2015/9/30 2016/5/15 2016/12/29 2017/8/14 2018/3/30 2018/11/13 2019/6/30

ヨウ素

(I)-

129濃度

(Bq/L

)高性能多核種除去設備(高性能ALPS)【ヨウ素(I)-129】 告示濃度限度(9Bq/L) 処理前

処理前(ND)※1 設備出口設備出口(ND)※1

Radiation concentrations measured at the multi-nuclide removal equipment (ALPS) outlet

(Iodine-129 concentration)

High-performance ALPS(Iodone-129)Io

din

e-1

29 c

oncentr

ation(B

q/L

)

- - Limits for concentrations required by law(9Bq/L)

● Prior to treatment〇 Prior to treatment (ND) ※1

■ Equipment outlet□ Equipment outlet (ND) ※1

※1 “ND” means that concentrations were below detectable limits.

Page 16: Radiation concentrations measured at the multi …...多核種除去設備(既設ALPS)【ストロンチウム(Sr)-90】 告示濃度限度(30Bq/L) 処理前 処理前(ND)※1

©Tokyo Electric Power Company Holdings. Inc. All Rights Reserved 15

1

10

100

1,000

10,000

100,000

1,000,000

10,000,000

100,000,000

1,000,000,000

10,000,000,000

2013/4/1 2013/11/15 2014/7/1 2015/2/14 2015/9/30 2016/5/15 2016/12/29 2017/8/14 2018/3/30 2018/11/13 2019/6/30

全ベータ

(β)濃

度(B

q/L

)

増設多核種除去設備(増設ALPS)【全ベータ(β)】 処理前 処理前(ND)※1設備出口A 設備出口A(ND)※1設備出口B 設備出口B(ND)※1設備出口C 設備出口C(ND)※1

1

10

100

1,000

10,000

100,000

1,000,000

10,000,000

100,000,000

1,000,000,000

10,000,000,000

2013/4/1 2013/11/15 2014/7/1 2015/2/14 2015/9/30 2016/5/15 2016/12/29 2017/8/14 2018/3/30 2018/11/13 2019/6/30

全ベータ

(β)濃

度(B

q/L

)

多核種除去設備(既設ALPS)【全ベータ(β)】 処理前 処理前(ND)※1

設備出口A 設備出口A(ND)※1

設備出口B 設備出口B(ND)※1

設備出口C 設備出口C(ND)※1

Radiation concentrations measured at the multi-nuclide removal equipment (ALPS) outlet

(All β concentration)

Additionally installed ALPS(All β)

Existing ALPS(All β)A

ll β

concentr

ation(B

q/L

)

All

βconcentr

ation(B

q/L

)

● Prior to treatment 〇 Prior to treatment(ND) ※1

■ Equipment outlet A □ Equipment outlet A(ND) ※1

▲ Equipment outlet B △ Equipment outlet B(ND) ※1

◆ Equipment outlet C ◇ Equipment outlet C(ND) ※1

● Prior to treatment 〇 Prior to treatment(ND) ※1

■ Equipment outlet A □ Equipment outlet A(ND) ※1

▲ Equipment outlet B △ Equipment outlet B(ND) ※1

◆ Equipment outlet C ◇ Equipment outlet C(ND) ※1

※1 “ND” means that concentrations were below detectable limits.

Page 17: Radiation concentrations measured at the multi …...多核種除去設備(既設ALPS)【ストロンチウム(Sr)-90】 告示濃度限度(30Bq/L) 処理前 処理前(ND)※1

©Tokyo Electric Power Company Holdings. Inc. All Rights Reserved 16

1

10

100

1,000

10,000

100,000

1,000,000

10,000,000

100,000,000

1,000,000,000

10,000,000,000

2013/4/1 2013/11/15 2014/7/1 2015/2/14 2015/9/30 2016/5/15 2016/12/29 2017/8/14 2018/3/30 2018/11/13 2019/6/30

全ベータ

(β)濃

度(B

q/L

)

高性能多核種除去設備(高性能ALPS)【全ベータ(β)】 処理前 処理前(ND)※1

設備出口 設備出口(ND)※1

Radiation concentrations measured at the multi-nuclide removal equipment (ALPS) outlet

(All β concentration)

High-performance ALPS(All β) ● Prior to treatment〇 Prior to treatment (ND) ※1

■ Equipment outlet□ Equipment outlet (ND) ※1

All

βconcentr

ation(B

q/L

)

※1 “ND” means that concentrations were below detectable limits.

Page 18: Radiation concentrations measured at the multi …...多核種除去設備(既設ALPS)【ストロンチウム(Sr)-90】 告示濃度限度(30Bq/L) 処理前 処理前(ND)※1

©Tokyo Electric Power Company Holdings. Inc. All Rights Reserved 17

0.01

0.1

1

10

100

1,000

10,000

100,000

2013/4/1 2013/11/15 2014/7/1 2015/2/14 2015/9/30 2016/5/15 2016/12/29 2017/8/14 2018/3/30 2018/11/13 2019/6/30

マンガン

(Mn)-

54濃度

(Bq/L

)

増設多核種除去設備(増設ALPS)【マンガン(Mn)-54】告示濃度限度(1000Bq/L) 処理前処理前(ND)※1 設備出口A設備出口A(ND)※1 設備出口B設備出口B(ND)※1 設備出口C設備出口C(ND)※1

0.01

0.1

1

10

100

1,000

10,000

100,000

2013/4/1 2013/11/15 2014/7/1 2015/2/14 2015/9/30 2016/5/15 2016/12/29 2017/8/14 2018/3/30 2018/11/13 2019/6/30

マンガン

(Mn)-

54濃度

(Bq/L

)

多核種除去設備(既設ALPS)【マンガン(Mn)-54】告示濃度限度(1000Bq/L) 処理前処理前(ND)※1 設備出口A設備出口A(ND)※1 設備出口B設備出口B(ND)※1 設備出口C設備出口C(ND)※1

Radiation concentrations measured at the multi-nuclide removal equipment (ALPS) outlet

(Manganese-54 concentration)

Existing ALPS(Manganese-54)IM

anganese-5

4 c

oncentr

ation(B

q/L

)

Manganese

-54 c

oncentr

ation(B

q/L

)

- - Limits for concentrations required by law(1,000Bq/L)

● Prior to treatment〇 Prior to treatment (ND) ※1■ Equipment outlet A□ Equipment outlet A (ND) ※1▲ Equipment outlet B△ Equipment outlet B (ND) ※1◆ Equipment outlet C◇ Equipment outlet C (ND) ※1

- - Limits for concentrations required by law(1,000Bq/L)

● Prior to treatment〇 Prior to treatment (ND) ※1■ Equipment outlet A□ Equipment outlet A (ND) ※1▲ Equipment outlet B△ Equipment outlet B (ND) ※1◆ Equipment outlet C◇ Equipment outlet C (ND) ※1

Additionally installed ALPS(Manganese-54)

※1 “ND” means that concentrations were below detectable limits.

Page 19: Radiation concentrations measured at the multi …...多核種除去設備(既設ALPS)【ストロンチウム(Sr)-90】 告示濃度限度(30Bq/L) 処理前 処理前(ND)※1

©Tokyo Electric Power Company Holdings. Inc. All Rights Reserved 18

0.01

0.1

1

10

100

1,000

10,000

100,000

2013/4/1 2013/11/15 2014/7/1 2015/2/14 2015/9/30 2016/5/15 2016/12/29 2017/8/14 2018/3/30 2018/11/13 2019/6/30

マンガン

(Mn)-

54濃度

(Bq/L

)

高性能多核種除去設備(高性能ALPS)【マンガン(Mn)-54】 告示濃度限度(1000Bq/L) 処理前処理前(ND)※1 設備出口設備出口(ND)※1

Radiation concentrations measured at the multi-nuclide removal equipment (ALPS) outlet

(Manganese-54 concentration)

High-performance ALPS(Manganese-54) - - Limits for concentrations required by law(1,000Bq/L)

● Prior to treatment〇 Prior to treatment (ND) ※1

■ Equipment outlet□ Equipment outlet (ND) ※1

IManganese

-54 c

oncentr

ation(B

q/L

)

※1 “ND” means that concentrations were below detectable limits.

Page 20: Radiation concentrations measured at the multi …...多核種除去設備(既設ALPS)【ストロンチウム(Sr)-90】 告示濃度限度(30Bq/L) 処理前 処理前(ND)※1

©Tokyo Electric Power Company Holdings. Inc. All Rights Reserved 19

0.01

0.1

1

10

100

1,000

10,000

100,000

1,000,000

10,000,000

2013/4/1 2013/11/15 2014/7/1 2015/2/14 2015/9/30 2016/5/15 2016/12/29 2017/8/14 2018/3/30 2018/11/13 2019/6/30ストロンチウム

(Sr)

-89濃度

(Bq

/L)

増設多核種除去設備(増設ALPS)【ストロンチウム(Sr)-89】告示濃度限度(300Bq/L) 処理前処理前(ND)※1 設備出口A設備出口A(ND)※1 設備出口B設備出口B(ND)※1 設備出口C設備出口C(ND)※1

0.01

0.1

1

10

100

1,000

10,000

100,000

1,000,000

10,000,000

2013/4/1 2013/11/15 2014/7/1 2015/2/14 2015/9/30 2016/5/15 2016/12/29 2017/8/14 2018/3/30 2018/11/13 2019/6/30ストロンチウム

(Sr)

-89濃度

(Bq/L

)

多核種除去設備(既設ALPS)【ストロンチウム(Sr)-89】告示濃度限度(300Bq/L) 処理前処理前(ND)※1 設備出口A設備出口A(ND)※1 設備出口B設備出口B(ND)※1 設備出口C設備出口C(ND)※1

Radiation concentrations measured at the multi-nuclide removal equipment (ALPS) outlet

(Strontium-89 concentration)

Additionally installed ALPS(Strontium-89)

Existing ALPS(Strontium-89)S

trontium

-89 c

oncentr

ation(B

q/L

)

Str

ontium

-89 c

oncentr

ation(B

q/L

)

- - Limits for concentrations required by law(300Bq/L)

● Prior to treatment〇 Prior to treatment (ND) ※1■ Equipment outlet A□ Equipment outlet A (ND) ※1▲ Equipment outlet B△ Equipment outlet B (ND) ※1◆ Equipment outlet C◇ Equipment outlet C (ND) ※1

- - Limits for concentrations required by law(300Bq/L)

● Prior to treatment〇 Prior to treatment (ND) ※1■ Equipment outlet A□ Equipment outlet A (ND) ※1▲ Equipment outlet B△ Equipment outlet B (ND) ※1◆ Equipment outlet C◇ Equipment outlet C (ND) ※1

※1 “ND” means that concentrations were below detectable limits.

Page 21: Radiation concentrations measured at the multi …...多核種除去設備(既設ALPS)【ストロンチウム(Sr)-90】 告示濃度限度(30Bq/L) 処理前 処理前(ND)※1

©Tokyo Electric Power Company Holdings. Inc. All Rights Reserved 20

0.01

0.1

1

10

100

1,000

10,000

100,000

1,000,000

10,000,000

2013/4/1 2013/11/15 2014/7/1 2015/2/14 2015/9/30 2016/5/15 2016/12/29 2017/8/14 2018/3/30 2018/11/13 2019/6/30ストロンチウム

(Sr)

-89濃度

(Bq/L

)高性能多核種除去設備(高性能ALPS)【ストロンチウム(Sr)-89】 告示濃度限度(300Bq/L) 処理前

処理前(ND)※1 設備出口設備出口(ND)※1

High-performance ALPS(Strontium-89)

Radiation concentrations measured at the multi-nuclide removal equipment (ALPS) outlet

(Strontium-89 concentration) S

trontium

-89 c

oncentr

ation(B

q/L

)

- - Limits for concentrations required by law(300Bq/L)

● Prior to treatment〇 Prior to treatment (ND) ※1

■ Equipment outlet□ Equipment outlet (ND) ※1

※1 “ND” means that concentrations were below detectable limits.

Page 22: Radiation concentrations measured at the multi …...多核種除去設備(既設ALPS)【ストロンチウム(Sr)-90】 告示濃度限度(30Bq/L) 処理前 処理前(ND)※1

©Tokyo Electric Power Company Holdings. Inc. All Rights Reserved 21

0.1

1

10

100

1,000

10,000

2013/4/1 2013/11/15 2014/7/1 2015/2/14 2015/9/30 2016/5/15 2016/12/29 2017/8/14 2018/3/30 2018/11/13 2019/6/30

テクネチウム

(Tc)-

99濃度

(Bq/L

)

増設多核種除去設備(増設ALPS)【テクネチウム(Tc)-99】告示濃度限度(1000Bq/L) 処理前処理前(ND)※1 設備出口A設備出口A(ND)※1 設備出口B設備出口B(ND)※1 設備出口C設備出口C(ND)※1

0.1

1

10

100

1,000

10,000

2013/4/1 2013/11/15 2014/7/1 2015/2/14 2015/9/30 2016/5/15 2016/12/29 2017/8/14 2018/3/30 2018/11/13 2019/6/30

テクネチウム

(Tc)-

99濃度

(Bq/L

)多核種除去設備(既設ALPS)【テクネチウム(Tc)-99】

告示濃度限度(1000Bq/L) 処理前処理前(ND)※1 設備出口A設備出口A(ND)※1 設備出口B設備出口B(ND)※1 設備出口C設備出口C(ND)※1

Radiation concentrations measured at the multi-nuclide removal equipment (ALPS) outlet

(Technetium-99 concentration)

Additionally installed ALPS(Technetium-99)

Existing ALPS(Technetium-99)T

echnetium

-99 c

oncentr

ation(B

q/L

)

Technetium

-99 c

oncentr

ation(B

q/L

)

- - Limits for concentrations required by law(1,000Bq/L)

● Prior to treatment〇 Prior to treatment (ND) ※1■ Equipment outlet A□ Equipment outlet A (ND) ※1▲ Equipment outlet B△ Equipment outlet B (ND) ※1◆ Equipment outlet C◇ Equipment outlet C (ND) ※1

- - Limits for concentrations required by law(1,000Bq/L)

● Prior to treatment〇 Prior to treatment (ND) ※1■ Equipment outlet A□ Equipment outlet A (ND) ※1▲ Equipment outlet B△ Equipment outlet B (ND) ※1◆ Equipment outlet C◇ Equipment outlet C (ND) ※1

※1 “ND” means that concentrations were below detectable limits.

Page 23: Radiation concentrations measured at the multi …...多核種除去設備(既設ALPS)【ストロンチウム(Sr)-90】 告示濃度限度(30Bq/L) 処理前 処理前(ND)※1

©Tokyo Electric Power Company Holdings. Inc. All Rights Reserved 22

0.1

1

10

100

1,000

10,000

2013/4/1 2013/11/15 2014/7/1 2015/2/14 2015/9/30 2016/5/15 2016/12/29 2017/8/14 2018/3/30 2018/11/13 2019/6/30

テクネチウム

(Tc)-

99濃度

(Bq/L

)高性能多核種除去設備(高性能ALPS)【テクネチウム(Tc)-99】 告示濃度限度(1000Bq/L) 処理前

処理前(ND)※1 設備出口設備出口(ND)※1

- - Limits for concentrations required by law((1000Bq/L)

● Prior to treatment〇 Prior to treatment (ND) ※1

■ Equipment outlet□ Equipment outlet (ND) ※1

Radiation concentrations measured at the multi-nuclide removal equipment (ALPS) outlet

(Technetium-99 concentration)

High-performance ALPS(Technetium-99)T

echnetium

-99 c

oncentr

ation(B

q/L

)

- - Limits for concentrations required by law((1,000Bq/L)

● Prior to treatment〇 Prior to treatment (ND) ※1

■ Equipment outlet□ Equipment outlet (ND) ※1

※1 “ND” means that concentrations were below detectable limits.

Page 24: Radiation concentrations measured at the multi …...多核種除去設備(既設ALPS)【ストロンチウム(Sr)-90】 告示濃度限度(30Bq/L) 処理前 処理前(ND)※1

©Tokyo Electric Power Company Holdings. Inc. All Rights Reserved 23

1

10

100

1,000

10,000

100,000

1,000,000

2013/4/1 2013/11/15 2014/7/1 2015/2/14 2015/9/30 2016/5/15 2016/12/29 2017/8/14 2018/3/30 2018/11/13 2019/6/30

ロジウム

(Rh)-

106濃度

(Bq/L

)

増設多核種除去設備(増設ALPS)【ロジウム(Rh)-106】告示濃度限度(300000Bq/L) 処理前処理前(ND)※1 設備出口A設備出口A(ND)※1 設備出口B設備出口B(ND)※1 設備出口C設備出口C(ND)※1

1

10

100

1,000

10,000

100,000

1,000,000

2013/4/1 2013/11/15 2014/7/1 2015/2/14 2015/9/30 2016/5/15 2016/12/29 2017/8/14 2018/3/30 2018/11/13 2019/6/30

ロジウム

(Rh)-

106濃度

(Bq/L

)

多核種除去設備(既設ALPS)【ロジウム(Rh)-106】告示濃度限度(300000Bq/L) 処理前処理前(ND)※1 設備出口A設備出口A(ND)※1 設備出口B設備出口B(ND)※1 設備出口C設備出口C(ND)※1

Radiation concentrations measured at the multi-nuclide removal equipment (ALPS) outlet

(Rhodium-106 concentration)

Additionally installed ALPS(Rhodium-106)

Existing ALPS(Rhodium-106)R

hodiu

m-1

06 c

oncentr

ation(B

q/L

)

Rhodiu

m-1

06 c

oncentr

ation(B

q/L

)

- - Limits for concentrations required by law(300,000Bq/L)

● Prior to treatment〇 Prior to treatment (ND) ※1■ Equipment outlet A□ Equipment outlet A (ND) ※1▲ Equipment outlet B△ Equipment outlet B (ND) ※1◆ Equipment outlet C◇ Equipment outlet C (ND) ※1

※1 “ND” means that concentrations were below detectable limits.

- - Limits for concentrations required by law(300,000Bq/L)

● Prior to treatment〇 Prior to treatment (ND) ※1■ Equipment outlet A□ Equipment outlet A (ND) ※1▲ Equipment outlet B△ Equipment outlet B (ND) ※1◆ Equipment outlet C◇ Equipment outlet C (ND) ※1

Page 25: Radiation concentrations measured at the multi …...多核種除去設備(既設ALPS)【ストロンチウム(Sr)-90】 告示濃度限度(30Bq/L) 処理前 処理前(ND)※1

©Tokyo Electric Power Company Holdings. Inc. All Rights Reserved 24

1

10

100

1,000

10,000

100,000

1,000,000

2013/4/1 2013/11/15 2014/7/1 2015/2/14 2015/9/30 2016/5/15 2016/12/29 2017/8/14 2018/3/30 2018/11/13 2019/6/30

ロジウム

(Rh)-

106濃度

(Bq/L

)高性能多核種除去設備(高性能ALPS)【ロジウム(Rh)-106】 告示濃度限度(300000Bq/L) 処理前

処理前(ND)※1 設備出口設備出口(ND)※1

High-performance ALPS(Rhodium-106)R

hodiu

m-1

06 c

oncentr

ation(B

q/L

)

- - Limits for concentrations required by law((300,000Bq/L)

● Prior to treatment〇 Prior to treatment (ND) ※1

■ Equipment outlet□ Equipment outlet (ND) ※1

Radiation concentrations measured at the multi-nuclide removal equipment (ALPS) outlet

(Rhodium-106 concentration)

※1 “ND” means that concentrations were below detectable limits.

Page 26: Radiation concentrations measured at the multi …...多核種除去設備(既設ALPS)【ストロンチウム(Sr)-90】 告示濃度限度(30Bq/L) 処理前 処理前(ND)※1

©Tokyo Electric Power Company Holdings. Inc. All Rights Reserved 25

0.01

0.1

1

10

100

2013/4/1 2013/11/15 2014/7/1 2015/2/14 2015/9/30 2016/5/15 2016/12/29 2017/8/14 2018/3/30 2018/11/13 2019/6/30

全アルファ

(α)濃

度(B

q/L

)

増設多核種除去設備(増設ALPS)【全アルファ(α)】処理前 処理前(ND)※1

設備出口A 設備出口A(ND)※1

設備出口B 設備出口B(ND)※1

設備出口C 設備出口C(ND)※1

0.01

0.1

1

10

100

2013/4/1 2013/11/15 2014/7/1 2015/2/14 2015/9/30 2016/5/15 2016/12/29 2017/8/14 2018/3/30 2018/11/13 2019/6/30

全アルファ

(α)濃

度(B

q/L

)多核種除去設備(既設ALPS)【全アルファ(α)】 処理前 処理前(ND)※1

設備出口A 設備出口A(ND)※1設備出口B 設備出口B(ND)※1設備出口C 設備出口C(ND)※1

Radiation concentrations measured at the multi-nuclide removal equipment (ALPS) outlet

(All α concentration)

Additionally installed ALPS(All α)

Existing ALPS(All α)A

ll α

concentr

ation(B

q/L

)

All

α c

oncentr

ation(B

q/L

)

● Prior to treatment 〇 Prior to treatment(ND) ※1

■ Equipment outlet A □ Equipment outlet A(ND) ※1

▲ Equipment outlet B △ Equipment outlet B(ND) ※1

◆ Equipment outlet C ◇ Equipment outlet C(ND) ※1

● Prior to treatment 〇 Prior to treatment(ND) ※1

■ Equipment outlet A □ Equipment outlet A(ND) ※1

▲ Equipment outlet B △ Equipment outlet B(ND) ※1

◆ Equipment outlet C ◇ Equipment outlet C(ND) ※1

※1 “ND” means that concentrations were below detectable limits.

Page 27: Radiation concentrations measured at the multi …...多核種除去設備(既設ALPS)【ストロンチウム(Sr)-90】 告示濃度限度(30Bq/L) 処理前 処理前(ND)※1

©Tokyo Electric Power Company Holdings. Inc. All Rights Reserved 26

0.01

0.1

1

10

100

2013/4/1 2013/11/15 2014/7/1 2015/2/14 2015/9/30 2016/5/15 2016/12/29 2017/8/14 2018/3/30 2018/11/13 2019/6/30

全アルファ

(α)濃

度(B

q/L

)高性能多核種除去設備(高性能ALPS)【全アルファ(α)】 処理前 処理前(ND)※1

設備出口 設備出口(ND)※1

High-performance ALPS(All α)

Radiation concentrations measured at the multi-nuclide removal equipment (ALPS) outlet

(All α concentration)

All

α c

oncentr

ation(B

q/L

)

● Prior to treatment〇 Prior to treatment (ND) ※1

■ Equipment outlet□ Equipment outlet (ND) ※1

※1 “ND” means that concentrations were below detectable limits.

Page 28: Radiation concentrations measured at the multi …...多核種除去設備(既設ALPS)【ストロンチウム(Sr)-90】 告示濃度限度(30Bq/L) 処理前 処理前(ND)※1

©Tokyo Electric Power Company Holdings. Inc. All Rights Reserved 27

10,000

100,000

1,000,000

10,000,000

2011/3/1 2012/5/8 2013/7/17 2014/9/25 2015/12/4 2017/2/11 2018/4/22 2019/6/30

H-3濃度(Bq/L)

【H-3】 告示濃度限度(60,000Bq/L)

H-3(RO装置入口)

[Reference]

Tritium (H-3) concentration trends at desalination (RO) equipment inlets

Tritium

concentr

ation(B

q/L

) Tritium (H-3)

- - Limits for concentrations required by law(600,000Bq/L)

● Tritium(desalination (RO) equipment inlets)